Search NASA⌕ Search

SEARCH · Search NASA

Results for “facility development”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

Highly lead-loaded red plastic scintillators as an X-ray imaging system for the Laser Mega Joule

The scope of this project intends to record spatially resolved images of core shape and size of a DT micro-balloon during Inertial Confinement Fusion (ICF) experiments at Laser Mega Joule facility (LMJ). We need to develop an X-ray imaging system which can operate in the radiative background generated by an ignition shot of ICF. The scintillator is a part of the imaging system and has to gather a compromise of scintillating properties (scintillating efficiency, decay time, emission wavelength) so as to both operate in the hard radiative environment and to allow the acquisition of spatially resolved images. Inorganic scintillators cannot be used because no compromise can be found regarding the expected scintillating properties, most of them are not fast enough and emit blue light. Organic scintillators are generally fast, but present low X-ray absorption in the 10 to 40 keV range, that does not permit the acquisition of spatially resolved images. To this aim, we have developed highly lead-loaded and red-fluorescent fast plastic scintillators. Such a combination is not currently available via scintillator suppliers, since they propose only blue-fluorescent plastic scintillators doped with up to 12%w Pb. Thus, incorporation ratio up to 27%w Pb has been reached in our laboratory, which can afford a plastic scintillator with an outstanding Z{sub eff} close to 50. X-rays in the 10 to 40 keV range can thus be detected with a higher probability of photoelectric effect than for classic organic scintillators, such as NE102. The strong orange-red fluorescence can be filtered, so that we can eliminate residual Cerenkov light, generated by {gamma}-ray absorption in glass parts of the imaging system. Decay times of our scintillators evaluated under UV excitation were estimated to be in the range 10 to 13 ns. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Partial defect verification of spent fuel assemblies by PDET: Principle and field testing in Interim Spent fuel Storage Facility (CLAB) in Sweden

Here, the need for the development of a credible method and instrument for partial defect verification of spent fuel has been emphasized over a few decades in the safeguards communities as the diverted spent fuel pins can be the source of nuclear terrorism or devices. The need is increasingly more important and even urgent as many countries have started to transfer spent fuel to so called "difficult-to-access" areas such as dry storage casks, reprocessing or geological repositories. Partial defect verification is required by IAEA before spent fuel is placed into "difficult-to-access" areas. Earlier, Lawrence Livermore National Laboratory (LLNL) has reported the successful development of a new, credible partial defect verification method for pressurized water reactor (PWR) spent fuel assemblies without use of operator data, and further reported the validation experiments using commercial spent fuel assemblies with some missing fuel pins. The method was found to be robust as the method is relatively invariant to the characteristic variations of spent fuel assemblies such as initial fuel enrichment, cooling time, and burn-up. Since then, the PDET system has been designed and prototyped for 17×17 PWR spent fuel assemblies, complete with data acquisition software and acquisition electronics. In this paper, a summary description of the PDET development followed by results of the first successful field testing using the integrated PDET system and actual spent fuel assemblies performed in a commercial spent fuel storage site, known as Central Interim Spent fuel Storage Facility (CLAB) in Sweden will be presented. In addition to partial defect detection initial studies have determined that the tool can be used to verify the operator declared average burnup of the assembly as well as intra-assembly bunrup levels.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Verification Testing of ITER Nb 3 Sn Strand at the NHMFL

The large amount of Nb 3 Sn superconducting wire needed by ITER presents a significant challenge to ensure that all wires adhere to ITER specifications. The National High Magnetic Field Laboratory, USA performed verification tests for Nb 3 Sn strands used in ITER TF magnets. Converting a research laboratory into a large quantity testing facility presented many challenges in developing standard operating procedures for all the verification tests. Verification tests required by ITER include: unreacted-chrome-plated strand diameter, twist pitch and twist direction, chrome-plating thickness, unreacted-chrome-plated strand Cu-to-non-Cu volume ratio, residual resistivity ratio of Cr-plated strand (RRR), critical current at 4.22 K and 12 T (I c ), resistive transition index at 4.22 K and 12 T (n-value), and hysteresis loss per strand unit volume at 4.22 K over a ±3 T cycle. Additionally, due to the brittle nature of Nb 3 Sn superconducting wire, some samples were damaged in a controlled manner to explore the negative extremes of damage due to sample handling. Finally, we successfully completed the verification tests of ITER TF Nb 3 Sn strands made by US vendors.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Conceptual Design of a Large Aperture Dipole for Testing of Cables and Insert Coils at High Field

© 2017 IEEE. Advances in the performance of low- and high-temperature superconductors enable the development of advanced magnets for a range of applications, including tokamaks for fusion energy, dipoles, and quadrupoles for hadron colliders, and solenoids for nuclear magnetic resonance studies. The capability of testing prototype cables and insert coils at high field is critical to these developments. We present here the conceptual design of a test facility dipole with features suitable to support the advanced magnet development efforts of both Fusion and HEP communities. In particular, a background field of 15 T is provided over a minimum homogeneous length of 1000 mm, and the magnet clear bore of approximately 144 × 94 mm can accommodate large fusion conductors as well as prototype coils for high field dipoles, along with flexible cryogenic and mechanical provisions for sample characterization. Two technical solutions are considered. The first uses a forced flow cable-in-conduit conductor and follows the design developed by EFDA for the EDIPO magnet. The second uses a bath cooled Rutherford cable and follows a block-coil design similar to the CERN FRESCA2 dipole, and the LBNL HD and LD1 dipoles. Following a comparison between the two approaches, we present two designs for the Rutherford cable approach including performance objectives, key parameters, and preliminary magnetic, mechanical and quench protection analysis.

Bruzzone, Pierluigi↗

Core Fueling of DEMO by Direct Line Injection of High-Speed Pellets From the HFS

Pellet injection represents to date the most realistic candidate technology for core fueling of a demonstration fusion power reactor tokamak fusion reactor. Modeling of both pellet penetration and fuel deposition profiles, for different injection locations, indicates that effective core fuelling can be achieved launching pellets from the inboard high field side at speeds not less than ~ 1 km/s. Inboard pellet fueling is commonly achieved in present tokamaks, using curved guide tubes; however, this technology might be hampered at velocities ≥ 1 km/s. An innovative approach, aimed at identifying suitable inboard "direct line'' paths, to inject high-speed pellets (in the 3 to 4 km/s range), has recently been proposed as a potential complementary solution. The fuel deposition profiles achievable by this approach have been explored using the HPI2 simulation code. The results presented here show that there are possible geometrical schemes providing good fueling performance. The problem of neutron flux in a direct line-of-sight injection path is being investigated, though preliminary analyses indicate that, perhaps, this is not a serious problem. The identification and integration of straight injection paths suitably tilted may be a rather difficult task due to the many constraints and to interference with existing structures. The suitability of straight guide tubes to reduce the scatter cone of high-speed pellets is, therefore, of main interest. A preliminary investigation, aimed at addressing these technological issues, has recently been started. As a result, a possible implementation plan, using an existing Italian National Agency for New Technologies, Energy and Sustainable Economic Development-Oak Ridge National Laboratory facility is shortly outlined.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Overview of the United States department of energy's used fuel disposition research and development campaign

The United States Department of Energy (US DOE) is conducting research and development (R and D) activities within the Used Fuel Disposition Campaign (UFDC) to support storage, transportation, and disposal of used nuclear fuel (UNF) and wastes generated by existing and future nuclear fuel cycles. R and D activities are ongoing at nine national laboratories, and are divided into two major topical areas: (1) storage and transportation research, and (2) disposal research. Storage R and D focuses on closing technical gaps related to extended storage of UNF. For example, uncertainties remain regarding high-burnup nuclear fuel cladding performance following possible hydride reorientation and creep deformation, and also regarding long-term canister integrity. Transportation R and D focuses on ensuring transportability of UNF following extended storage, addressing data gaps regarding nuclear fuel integrity, retrievability, and demonstration of subcriticality. Disposal R and D focuses on identifying multiple viable geologic disposal options and addressing technical challenges for generic disposal concepts in various host media (e.g., mined repositories in salt, clay/shale, and granitic rocks, and deep borehole disposal in crystalline rock). R and D will transition to site-specific challenges as national policy advances. R and D goals at this stage are to increase confidence in the robustness of generic disposal concepts, to reduce generic sources of uncertainty that may impact the viability of disposal concepts, and to develop science and engineering tools that will support the selection, characterization, and ultimately licensing of a repository. The US DOE has also initiated activities that can be conducted within the constraints of the Nuclear Waste Policy Act to facilitate the development of an interim storage facility and supporting transportation infrastructure. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Soft Microfluidic Assemblies of Sensors, Circuits, and Radios for the Skin

When mounted on the skin, modern sensors, circuits, radios, and power supply systems have the potential to provide clinical-quality health monitoring capabilities for continuous use, beyond the confines of traditional hospital or laboratory facilities. The most well-developed component technologies are, however, broadly available only in hard, planar formats. As a result, existing options in system design are unable to effectively accommodate integration with the soft, textured, curvilinear, and time-dynamic surfaces of the skin. Here, we describe experimental and theoretical approaches for using ideas in soft microfluidics, structured adhesive surfaces, and controlled mechanical buckling to achieve ultralow modulus, highly stretchable systems that incorporate assemblies of high-modulus, rigid, state-of-the-art functional elements. Here, the outcome is a thin, conformable device technology that can softly laminate onto the surface of the skin to enable advanced, multifunctional operation for physiological monitoring in a wireless mode.

47 OTHER INSTRUMENTATION↗

NICA at JINR: New prospects for exploration of quark-gluon matter

A new scientific program is proposed at the Joint Institute for Nuclear Research (JINR) in Dubna aimed at studies of hot and dense baryonic matter in the wide energy range from 2 GeV/u kinetic energy in fixed target experiments to {radical}s{sub NN} = 4 - 11 GeV/u in the collider mode. To realize this program the development of the JINR accelerator facility in high-energy physics (HEP) has been started. This facility is based on the existing superconducting synchrotron-the Nuclotron. The program foresees both experiments at the beams extracted from the Nuclotron, and the construction of a heavy-ion collider-the Nuclotron-based Ion Collider fAcility (NICA) which is designed to reach the required parameters with an average luminosity of L = 10{sup 27} cm{sup -2} s{sup -1}.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Nuclear-nuclear collision centrality determination by the spectators calorimeter for the MPD setup at the NICA facility

The work conditions of the hadron calorimeter for spectators registration (Zero Degree Calorimeter, ZDC) were studied for the heavy nuclei collisions with the several GeV invariant energy. The ZDC simulations were performed for the MPD (Multi-Purpose Detector) at the NICA (Nuclotron-based Ion Collider fAcility) collider, which are under developement at the Joint Institute for Nuclear Research (JINR, Dubna). Taking into account the spectator nuclear fragments leads to a nonmonotonic dependence of the ZDC response on the impact parameter. The reason for this dependence studied with several event generators is the primary beam hole in the ZDC center. It is shown, that the ZDC signal should be combined with a data from other MPD-NICA detector subsystems to determine centrality.

74 ATOMIC AND MOLECULAR PHYSICS↗

Penning plasma based simultaneous light emission source of visible and VUV lights

In this paper, a laboratory-based penning plasma discharge source is reported which has been developed in two anode configurations and is able to produce visible and VUV lights simultaneously. The developed source has simultaneous diagnostics facility using Langmuir probe and optical emission spectroscopy. The two anode configurations, namely, double ring and rectangular configurations, have been studied and compared for optimum use of the geometry for efficient light emissions and recording. The plasma is produced using helium gas and admixture of three noble gases including helium, neon, and argon. The source is capable to produce eight spectral lines for pure helium in the VUV range from 20 to 60 nm and total 24 spectral lines covering the wavelength range 20–106 nm for the admixture of gases. The large range of VUV lines is generated from gaseous admixture rather from the sputtered materials. The recorded spectrum shows that the plasma light radiations in both visible and VUV range are larger in double ring configuration than that of the rectangular configurations at the same discharge operating conditions. To clearly understand the difference, the imaging of the discharge using ICCD camera and particle-in-cell simulation using VORPAL have also been carried out. The effect of ion diffusion, metastable collision with the anode wall and the nonlinear effects are correlated to explain the results.

74 ATOMIC AND MOLECULAR PHYSICS↗

Scientific Directions for Cloud Chamber Research: Instrumentation, Modeling, New Chambers, and Emerging Chamber Concepts

The Workshop on Scientific Directions for Cloud Chamber Research was held 13-14 July 2024 at the National Institute for Meteorological Sciences, Jeju, South Korea. Here, over 75 scientists from 13 countries gathered to learn about and discuss the latest scientific research results from large laboratory cloud chamber facilities, as well as new developments in cloud chamber instrumentation and modeling efforts, and emerging cloud chamber designs that will open new scientific research directions.

54 ENVIRONMENTAL SCIENCES↗

Architectural considerations for recirculated and energy recovered hard XFEL drivers

A confluence of events motivates discussion of design options for hard XFEL driver accelerators. Firstly, multiple superconducting radio-frequency (SRF) driven systems are now online (European XFEL), in construction (LCLS-II), or in design (MARIE); these provide increasing evidence of the transformational potential they offer for fundamental science with its concomitant benefits. Secondly, operation of 12 GeV CEBAF* validates use of recirculation in high energy SRF linacs. Thirdly, advances in the analysis and control of effects such as coherent synchrotron radiation (CSR) and the microbunching instability (uBI) have been recently achieved. Collectively, these developments offer insights providing extended facility science reach, reduced costs, multiplicity (i.e., support of numerous FELs operating over a range of wavelengths), and enhanced scalability and upgradability (to higher powers and energies). We will discuss the relationship amongst the various threads, and indicate how they inform design choices for the system architecture of an option for the UK-XFEL** - that of a staged multi-user X-ray FEL and nuclear physics facility based on a multi-pass recirculating SRF CW linac.

Benson, Stephen V.↗

Thermal-Mechanical Study of 3.9 GHz CW Coupler and Cavity for LCLS-II Project

Third harmonic system was originally developed by Fermilab for FLASH facility at DESY and then was adopted and modified by INFN for the XFEL project [1-3]. In contrast to XFEL project, all cryomodules in LCLS-II project will operate in CW regime with higher RF average power for 1.3 GHz and 3.9 GHz cavities and couplers. Design of the cavity and fundamental power coupler has been modified to satisfy LCLS-II requirements. In this paper we discuss the results of COMSOL thermal and mechanical analysis of the 3.9 GHz coupler and cavity to verify proposed modifica-tion of the design. For the dressed cavity we present simulations of Lorentz force detuning, helium pressure sensitivity df/dP and major mechanical resonances.

43 PARTICLE ACCELERATORS↗

NASA's Marshall Space Flight Center Saves Water With High-Efficiency Toilet and Urinal Program: Best Management Practice Case Study #6 - Toilets and Urinals (Fact Sheet)

The National Aeronautics and Space Administration's (NASA) Marshall Space Flight Center (MSFC) has a longstanding, successful sustainability program that focuses on energy and water efficiency as well as environmental protection. Because MSFC was built in the 1960s, most of the buildings house outdated, inefficient restroom fixtures. The facility engineering team at MSFC developed an innovativeefficiency model for replacing these older toilets and urinals.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

BENCH SCALE SALTSTONE PROCESS DEVELOPMENT MIXING STUDY

The Savannah River National Laboratory (SRNL) was requested to develop a bench scale test facility, using a mixer, transfer pump, and transfer line to determine the impact of conveying the grout through the transfer lines to the vault on grout properties. Bench scale testing focused on the effect the transfer line has on the rheological property of the grout as it was processed through the transfer line. Rheological and other physical properties of grout samples were obtained prior to and after pumping through a transfer line. The Bench Scale Mixing Rig (BSMR) consisted of two mixing tanks, grout feed tank, transfer pump and transfer hose. The mixing tanks were used to batch the grout which was then transferred into the grout feed tank. The contents of the feed tank were then pumped through the transfer line (hose) using a progressive cavity pump. The grout flow rate and pump discharge pressure were monitored. Four sampling stations were located along the length of the transfer line at the 5, 105 and 205 feet past the transfer pump and at 305 feet, the discharge of the hose. Scaling between the full scale piping at Saltstone to bench scale testing at SRNL was performed by maintaining the same shear rate and total shear at the wall of the transfer line. The results of scaling down resulted in a shorter transfer line, a lower average velocity, the same transfer time and similar pressure drops. The condition of flow in the bench scale transfer line is laminar. The flow in the full scale pipe is in the transition region, but is more laminar than turbulent. The resulting plug in laminar flow in the bench scale results in a region of no-mixing. Hence mixing, or shearing, at the bench scale should be less than that observed in the full scale, where this plug is non existent due to the turbulent flow. The bench scale tests should be considered to be conservative due to the highly laminar condition of flow that exists. Two BSMR runs were performed. In both cases, wall shearing was shown to reduce the rheological properties of the grout as it was processed through the transfer line. Samples taken at the static feed tank showed that gelling impacted the rheological properties of the grout before it was fed into the pump and transfer line. A comparison of the rheological properties of samples taken at the feed tank and transfer line discharge indicated shearing of the grout was occurring in the transfer line. Bench scale testing of different mixing methods with three different salt solutions showed that method of mixing influences the rheological properties of the grouts. The paddle blade mixing method of the salt solution used for the BMSR testing provided comparable rheological properties of the grout prepared in the BMSR after 14 minutes of processing, B3. The paddle blade mixing method can be used to represent BMSR results and mixing time can be adjusted to represent larger scale mixing.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Diode magnetic-field influence on radiographic spot size

Flash radiography of hydrodynamic experiments driven by high explosives is a well-known diagnostic technique in use at many laboratories. The Dual-Axis Radiography for Hydrodynamic Testing (DARHT) facility at Los Alamos was developed for flash radiography of large hydrodynamic experiments. Two linear induction accelerators (LIAs) produce the bremsstrahlung radiographic source spots for orthogonal views of each experiment ('hydrotest'). The 2-kA, 20-MeV Axis-I LIA creates a single 60-ns radiography pulse. For time resolution of the hydrotest dynamics, the 1.7-kA, 16.5-MeV Axis-II LIA creates up to four radiography pulses by slicing them out of a longer pulse that has a 1.6-{micro}s flattop. Both axes now routinely produce radiographic source spot sizes having full-width at half-maximum (FWHM) less than 1 mm.

43 PARTICLE ACCELERATORS↗

Continuation of full-scale three-dimensional numerical experiments on high-intensity particle and laser beam-matter interactions

We present results from the grant entitled, Continuation of full-scale three-dimensional numerical experiments on high-intensity particle and laser beam-matter interactions. The research significantly advanced the understanding of basic high-energy density science (HEDS) on ultra intense laser and particle beam plasma interactions. This advancement in understanding was then used to to aid in the quest to make 1 GeV to 500 GeV plasma based accelerator stages. The work blended basic research with three-dimensions fully nonlinear and fully kinetic simulations including full-scale modeling of ongoing or planned experiments. The primary tool was three-dimensional particle-in-cell simulations. The simulations provided a test bed for theoretical ideas and models as well as a method to guide experiments. The research also included careful benchmarking of codes against experiment. High-fidelity full-scale modeling provided a means to extrapolate parameters into regimes that were not accessible to current or near term experiments, thereby allowing concepts to be tested with confidence before tens to hundreds of millions of dollars were spent building facilities. The research allowed the development of a hierarchy of PIC codes and diagnostics that is one of the most advanced in the world.

43 PARTICLE ACCELERATORS↗

Simulations of the new DARHT Axis-II bucking coil magnetic field and effects

Flash radiography of hydrodynamic experiments driven by high explosives is a well-known diagnostic technique in use at many laboratories. The Dual-Axis Radiography for Hydrodynamic Testing (DARHT) facility at Los Alamos was developed for flash radiography of large hydrodynamic experiments. Two linear induction accelerators (LIAs) produce the bremsstrahlung radiographic source spots for orthogonal views of each experiment (“hydrotest”). The 2-kA, 20-MeV Axis-I LIA creates a single 60-ns radiography pulse. For time resolution of the hydrotest dynamics, the 1.7-kA, 16.5-MeV Axis-II LIA creates up to four radiography pulses by slicing them out of a longer pulse that has a 1.6-µs flattop. Both axes now routinely produce radiographic source spot sizes having full-width at half-maximum (FWHM) less than 1 mm.

43 PARTICLE ACCELERATORS↗