Search NASA⌕ Search

SEARCH · Search NASA

Results for “heterogeneous processing system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

Study of Buoyancy Effects in Diffusion Flames Using Rainbow Schlieren Deflectometry

Diffusion flames are extensively encountered in many domestic and industrial processes. Even after many decades of research, a complete understanding of the diffusion flame structure is not available. The structure and properties of the flames are governed by the mixing (laminar or turbulent), chemical kinetics, radiation and soot processes. Another important phenomenon that affects flame structure in normal gravity is buoyancy. The presence of buoyancy has long hindered the rational understanding of many combustion processes. In gas jet diffusion flames, buoyancy affects the structure of the shear layer, the development of fluid instabilities, and formation of the coherent structures in the near nozzle region of the gas jets. The buoyancy driven instabilities generate vorticial structures outside the flame resulting in flame flicker. The vortices also strongly interact with the small-scale structures in the jet shear layer. This affects the transitional and turbulence characteristics of the flame. For a fundamental understanding of diffusion flames it is essential to isolate the effects of buoyancy. This is the primary goal of the experiments conducted in microgravity. Previous investigations, have shown dramatic differences between the jet flames in microgravity and normal gravity. It has been observed that flames in microgravity are taller and more sooty than in normal gravity. The fuels used in these experiments were primarily hydrocarbons. In the absence of buoyancy the soot resides near the flame region, which adversely affects the entrainment of reactants. It is very important to eliminate the interference of soot on flame characteristics in microgravity. The present work, therefore, focuses on the changes in the flame structure due to buoyancy without the added complexities of heterogeneous reactions. Clean burning hydrogen is used as the fuel to avoid soot formation and minimize radiative losses. Because of the low luminosity of hydrogen flames, we use rainbow schlieren deflectometry for visualization. The visualized images are digitized for quantification.The work reported here is divided into three sections; rainbow schlieren deflectometry (RSD), microgravity experiments and sub-atmospheric pressure experiments. The first section demonstrates the application of RSD for quantitative measurements in non-reacting and reacting flow systems. A computational effort to complement the experimental work is also included. In the second section, the experiments conducted at the 2.2s NASA Lewis Drop tower facility are described. The experiments were conducted to study the behavior of laminar, transitional and turbulent hydrogen flames in microgravity. The ability of RSD technique to provide quantitative data is highlighted. The final section deals with the sub-atmospheric pressure tests, which demonstrate that buoyancy in hydrogen diffusion flames can be scaled with pressure at normal gravity.

Agrawal, Ajay K.↗

Atomic layer deposition of Cd x Zn 1-x S films

Deposition of Cdsub>x Zn 1-x S has been demonstrated with atomic layer deposition (ALD) using diethylzinc (DEZn), dimethylcadmium (DMCd), and hydrogen sulfide as the precursors, and DFT calculations were performed to simulate the ALD process and the properties of the deposited films. The relative ratio of the pulses is varied for DMCd and DEZn to achieve different compositions over the spectrum from pure CdS to pure ZnS. Overall, the cadmium content in the films is higher than would be expected both as a function of pulse ratio and of temperature based on the growth rates of the binary films. At 150 °C pure ZnS shows almost pure cubic nature; however, the wurtzite content increases with the presence of cadmium until the film is approximately 10% wurtzite for pure CdS. Transmission electron microscopy (TEM) with high resolution confirms the coexistence of zincblende and wurtzite within grains due to the presence of stacking faults. The roughness of the films is a function of the composition, and the band gap and index of refraction can be finely tuned with composition.

33 ADVANCED PROPULSION SYSTEMS↗

Nanoscale Three-Dimensional Imaging of Degradation in Composite Si-Containing Anodes

The use of silicon (Si) in next-generation lithium-ion battery (LIB) anodes has the potential to dramatically improve electrochemical performance over current LIB graphite (Gr) anodes, due to silicon’s higher specific capacity.1 However, widespread implementation of Si-containing anodes is inhibited by issues such as significant Si volume expansion during lithiation and an unstable solid-electrolyte interphase (SEI), resulting in unreliable performance and poor cycle life. Currently, composite anodes with both Si and graphite active materials are used to increase capacity and mitigate some of the limitations associated with Si. In composite electrodes with a heterogeneous distribution of components with varying electrical properties (including Si, Gr, conductive carbon additive, and binder), it is important to understand the local distribution of each component to correlate with electrochemical processes, particularly localized degradation and heterogeneous aging, and to optimize performance. To investigate Si-containing composite anodes in the nanoscale, we use scanning spreading resistance microscopy (SSRM), a form of scanning probe microscopy (SPM) that probes local electronic resistivity. By examining the intrinsic electronic resistivity contrast between the anode components, separate phases can be distinguished and understood within the composite structure.2 This work studies the effect of electrochemical cycling in two different electrolytes on component distribution and aging by comparing the electrical and structural evolution of composite Si-graphite electrodes and SEI before and after charge-discharge cycling. 1. W. J. Zhang. A review of the electrochemical performance of alloy anodes for lithium-ion batteries J. Power Sources 196 13–24 (2011). 2. C. Stetson, Z. Huey, A. Downard, Z. Li, B. To, A. Zakutayev, C.-S. Jiang, M. Al-Jassim, D. Finegan, S.-D. Han and S. DeCaluwe: Three-Dimensional Mapping of Resistivity and Microstructure of Composite Electrodes for Lithium-Ion Batteries. ACS Nano Letters Accepted (2020).

ADVANCED PROPULSION SYSTEMS↗

MO-C-12A-01: Quantitative Imaging Initiatives: Why, Who, What, and How?

Over the past decade, there has been an increasing focus on quantitative imaging (QI), which, according to one definition, is “the extraction of quantifiable features from medical images for the assessment of normal or the severity, degree of change, or status of a disease, injury, or chronic condition relative to normal” ( www.rsna.org/QIBA ). To achieve the goals of QI requires the development and standardization of data acquisition, data analysis, and data display techniques, as well as appropriate reporting structures. As such, successful implementation of QI relies heavily on expertise from the fields of medical physics, radiology, statistics, and informatics as well as collaboration from vendors of imaging acquisition, analysis, and reporting systems. When successfully implemented, QI techniques will provide image-derived metrics with known bias and variance that can be validated with anatomically and physiologically relevant measures, including treatment response, and the heterogeneity of that response, and outcome. Such non-invasive measures can then be used effectively in clinical and translational research as well as patient care. In addition to modality-specific QI efforts implemented by individual scientific organizations, national and international organizations, including the NCI, RSNA, FDA, and NIST, appreciating the tremendous potential of QI but also understanding the associated challenges, have become increasingly involved. This symposium session will focus on 1) introducing QI and illustrating why it is important, even though challenging, in both research and clinical applications, and 2) providing overviews of QI efforts from national and international organizations, including the RSNA, NCI, FDA, and NIST. Learning Objectives: Understand the importance and potential of QI in research and clinical applications. Understand key challenges of QI and current barriers to implementation. Understand the current QI efforts of several national and international agencies and organizations, including the FDA, NCI, NIST, and RSNA.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-272: Direct Verification of a Treatment Planning System Megavoltage Linac Beam Photon Spectra Models, and Analysis of the Effects On Patient Plans

Purpose: For the photon dose calculation Philips Pinnacle Treatment Planning System (TPS) uses collapsed cone convolution algorithm, which relies on energy spectrum of the beam in computing the scatter component. The spectrum is modeled based on Linac’s standard commissioning data and typically is not independently verified. We explored a methodology of using transmission measurements in combination with regularization data processing to unfold Linac spectra. The measured spectra were compared to those modeled by the TPS, and the effect on patient plans was evaluated. Methods: Transmission measurements were conducted in narrow-beam geometry using a standard Farmer ionization chamber. Two attenuating materials and two build -up caps, having different atomic numbers, served to enhance discrimination between absorption of low and high-energy portions of the spectra, thus improving the accuracy of the results. The data was analyzed using a regularization technique implemented through spreadsheet-based calculations. Results: The unfolded spectra were found to deviate from the TPS beam models. The effect of such deviations on treatment planning was evaluated for patient plans through dose distribution calculations with either TPS modeled or measured energy spectra. The differences were reviewed through comparison of isodose distributions, and quantified based on maximum dose values for critical structures. While in most cases no drastic differences in the calculated doses were observed, plans with deviations of 4 to 8% in the maximum dose values for critical structures were discovered. The anatomical sites with large scatter contributions are the most vulnerable to inaccuracies in the modeled spectrum. Conclusion: An independent check of the TPS model spectrum is highly desirable and should be included as part of commissioning of a new Linac. The effect is particularly important for dose calculations in high heterogeneity regions. The developed approach makes acquisition of megavoltage Linac beam spectra achievable in a typical radiation oncology clinic.

60 APPLIED LIFE SCIENCES↗

TU-CD-BRB-02: BEST IN PHYSICS (JOINT IMAGING-THERAPY): Identification of Molecular Phenotypes by Integrating Radiomics and Genomics

Purpose: To uncover the mechanistic connections between radiomic features, molecular pathways, and clinical outcomes, to develop radiomic based predictors of pathway activation states in individual patients, and to assess whether combining radiomic with clinical and genomic data improves prognostication. Methods: We analyzed two independent lung cancer cohorts totaling 351 patients, for whom diagnostic computed tomography (CT) scans, gene-expression profiles, and clinical outcomes were available. The tumor phenotype was characterized based on 636 radiomic features describing tumor intensity, texture, shape and size. We performed an integrative analysis by developing and independently validating association modules of coherently expressed radiomic features and molecular pathways. These modules were statistically tested for significant associations to overall survival (OS), TNM stage, and pathologic histology. Results: We identified thirteen radiomic-pathway association modules (p < 0.05), the most prominent of which were associated with the immune system, p53 pathway, and other pathways involved in cell cycle regulation. Eleven modules were significantly associated with clinical outcomes (p < 0.05). Strong predictive power for pathway activation states in individual patients was observed using radiomics; the strongest per module predictions ranged from an intra-tumor heterogeneity feature predicting RNA III polymerase transcription (AUC 0.62, p = 0.03), to a tumor intensity dispersion feature predicting pyruvate metabolism and citric acid TCA cycle (AUC 0.72, p < 10−{sup 6}). Stepwise combinations of radiomic data with clinical outcomes and gene expression profiles resulted in consistent increases of prognostic power to predict OS (concordance index max = 0.73, p < 10−{sup 9}). Conclusion: This study demonstrates that radiomic approaches permit a non-invasive assessment of molecular and clinical characteristics of tumors, and therefore have the unprecedented potential to cost-effectively advance clinical decision-making using routinely acquired, standard-of-care imaging data. We show that prognostic value complementary to clinical and genomic information can be obtained by radiomic strategies.

60 APPLIED LIFE SCIENCES↗

Continuous snow depth, ground interface temperature and shallow soil temperature measurements from 2021-10-1 to 2022-6-14, Seward Peninsula, Alaska

The dataset contains co-located snow depth, ground interface temperature, and shallow soil temperature measured at 98 discrete locations in a watershed located along the Nome-Teller road at mile marker 27 (referred to as T27), and at 53 discrete locations on a hillslope located along the Kougarok road at mile marker 64 (referred to as K64), in Seward Peninsula, Alaska. The dataset aims to understand the local heterogeneity of snow depth, snow temperature, and soil temperature dynamics and their interactions in a discontinuous permafrost region. The dataset is also valuable to train and evaluate machine learning and physical models to predict snow depth or the impact of snow depth on ground surface temperature. At each location, temperatures above and below the ground surface were measured by a pair of vertically deployed distributed temperature profiling probes designed based on Dafflon et al (2022). The probes have high precision temperature sensors spaced at 5 or 10 cm. The mean daily snow depth was estimated by identifying the pair of consecutive sensors with maximum drop of daily temperature high-frequency fluctuations. The ground interface temperature was measured by the sensor located 1-5 cm above the ground surface at 15-minute intervals. The shallow soil temperature was measured by the sensor located 1-5 cm below the ground surface at 15-minute intervals. The dataset includes a description of the probe locations in the "Probe_locations_*.csv" file and the 3 data files (Snow_depths_*.csv, Ground_interface_temperatures_*.csv, Shallow_soil_temperatures_*.csv). * is either T27 or K64, which are the two study sites. In each data file, each column corresponds to a measurement location. Metadata files include data descriptions (_dd.csv) for tabular data. All included files are listed and described in xxxx_flmd.csv. A more detailed description of data processing, along with an updated dataset incorporating multiple seasons and improved snow depth estimation is available at https://doi.org/10.15485/2480365 (Wang et al., 2025a, Wang et al., 2025b).The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research.The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska.Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

Tuning the Kinetic Water Stability and Adsorption Interactions of Mg-MOF-74 by Partial Substitution with Co or Ni

Varying amounts of Co and Ni were substituted into the metal–organic framework Mg-MOF-74 via a one-pot solvothermal reaction, and the effects of these substitutions on CO 2 adsorption and kinetic water stability properties were examined. Based on elemental analyses, Co and Ni are more favorably incorporated into the MOF-74 framework from solution than Mg. In addition, reaction temperature more strongly impacts the final metal composition in these mixed-metal (MM) MOF-74 structures than does the reaction solvent composition. Single-component CO 2 adsorption isotherms were measured for the MM-MOF-74 systems at 5, 25, and 45 °C, and isosteric heats of adsorption were calculated. These results suggest that CO 2 adsorption properties can be adjusted by partial metal substitution. Water adsorption isotherms were also measured for the MM-MOF-74 samples, with powder X-ray diffraction patterns and Brunauer–Emmett–Teller surface areas measured both before and after water exposure. Results show that Mg-MOF-74 can gain partial kinetic water stability by the incorporation of Ni 2+ or Co 2+ metal ions that are less vulnerable to hydrolysis than Mg 2+ . Finally, of particular note, Mg–Ni-MM-MOF-74 shows a significant increase in water stability when incorporating as little as 16 mol % Ni into the Mg-MOF-74 structure.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Inverse methods for design of soft materials

Functional soft materials, comprising colloidal and molecular building blocks that self-organize into complex structures as a result of their tunable interactions, enable a wide array of technological applications. Inverse methods provide a systematic means for navigating their inherently high-dimensional design spaces to create materials with targeted properties. Furthermore, while multiple physically motivated inverse strategies have been successfully implemented in silico, their translation to guiding experimental materials discovery has thus far been limited to a handful of proof-of-concept studies. In this perspective, we discuss recent advances in inverse methods for design of soft materials that address two challenges: (1) methodological limitations that prevent such approaches from satisfying design constraints and (2) computational challenges that limit the size and complexity of systems that can be addressed. Strategies that leverage machine learning have proven particularly effective, including methods to discover order parameters that characterize complex structural motifs and schemes to efficiently compute macroscopic properties from the underlying structure. We also highlight promising opportunities to improve the experimental realizability of materials designed computationally, including discovery of materials with functionality at multiple thermodynamic states, design of externally directed assembly protocols that are simple to implement in experiments, and strategies to improve the accuracy and computational efficiency of experimentally relevant models.

36 MATERIALS SCIENCE↗

Palladium isotopic evidence for nucleosynthetic and cosmogenic isotope anomalies in IVB iron meteorites

The origin of ubiquitous nucleosynthetic isotope anomalies in meteorites may represent spatial and/or temporal heterogeneity in the sources that supplied material to the nascent solar nebula, or enhancement by chemical processing. For elements beyond the Fe peak, deficits in s-process isotopes have been reported in some (e.g., Mo, Ru, W) but not all refractory elements studied (e.g., Os) that, among the iron meteorites, are most pronounced in IVB iron meteorites. Palladium is a non-refractory element in the same mass region as Mo and Ru. In this study, we report the first precise Pd isotopic abundances from IVB irons to test the mechanisms proposed for the origin of isotope anomalies. First, this study determined the existence of a cosmogenic neutron dosimeter from the reaction {sup 103}Rh(n, β{sup −}){sup 104}Pd in the form of excess {sup 104}Pd, correlated with excess {sup 192}Pt, in IVB irons. Second, all IVB irons show a deficit of the s-process only isotope {sup 104}Pd (ε {sup 104}Pd = −0.48 ± 0.24), an excess of the r-only isotope {sup 110}Pd (ε{sup 110}Pd = +0.46 ± 0.12), and no resolvable anomaly in the p-process {sup 102}Pd (ε {sup 102}Pd = +1 ± 1). The magnitude of the Pd isotope anomaly is about half that predicted from a uniform depletion of the s-process yields from the correlated isotope anomalies of refractory Mo and Ru. The discrepancy is best understood as the result of nebular processing of the less refractory Pd, implying that all the observed nucleosynthetic anomalies in meteorites are likely to be isotopic relicts. The Mo–Ru–Pd isotope systematics do not support enhanced rates of the {sup 22}Ne(α,n){sup 25}Mg neutron source for the solar system s-process.

79 ASTRONOMY AND ASTROPHYSICS↗

Phase field-volumetric lattice Boltzmann model of ion uptake in porous nuclear waste form materials under continuous flow

The flow field within the mesopores of sorbent particles plays a crucial role in radionuclide diffusion and ion uptake kinetics, thus, impacting the overall performance of porous nuclear waste form materials. To fundamentally understand the influence of microstructures and material properties on the radionuclide absorption and retention processes requires a coupled multi-physics model that considers the advection and diffusion within the flow field, the reaction at liquid-solid interfaces, and finally, the solid-state diffusion within a complex nanoporous medium. Here, this study employs the volumetric lattice Boltzmann method (VLBM) to accurately and efficiently calculate the steady state velocity field inside the mesopores of sorbent particles. The obtained velocity field is then utilized to calculate the advection of ions in the steady flow. A phase field (PF) model of ion uptake is used to describe the reaction occurring at the solid-liquid interface and diffusion inside the porous medium. The integrated PF-VLBM model is verified in terms of the mass conservation and numerical efficiency and validated qualitatively with experimental observation data. Then, it is applied to study the influence of thermodynamic and kinetic properties, as well as flow field conditions on the ion uptake kinetics. The numerical results demonstrate that the ion uptake kinetics in porous particles has three distinct stages, which is in agreement with the observations in continuous flow experiments. In the first stage, the kinetics is predominantly controlled by the flow field and ion diffusivity in the liquid phase. The kinetics in the second stage is primarily governed by ion diffusivity in the solid phase. In the third stage the system reaches a dynamic equilibrium with a net zero uptake flux at the interface. It is also found that porous structures significantly affect the efficiency and capacity of ion uptake. The simulation results can help to understand the physics behind the observed ion uptake kinetics in experiments and to facilitate the development of constitutive equations that can account for heterogeneous microstructures in engineering performance codes.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Effects of Surface Hydrophobicity on Catalytic Transfer Hydrogenation of Styrene with Formic Acid in a Biphasic Mixture

Transfer hydrogenation (TH) of unsaturated hydrocarbons with formic acid (FA) is an attractive processing pathway for the reduction of lignocellulosic pyrolysis oils. The low solubility of hydrophobic bio-oil species in water and FA in oil necessitates the use of a biphasic system as the reaction environment. Here, we report the effects of Pd/silica catalyst surface wettability on the TH reaction rate. Modification of the surface with short chain (C1–C4) alkyl silanes resulted in an increase in the reaction rate as compared to the unmodified catalyst. In contrast, modification of the surface with sulfonate (hydrophilic) and C18 alkyl silanes (hydrophobic) resulted in a decrease in the reaction rate as compared to the unmodified catalyst. Here, the results are discussed in terms of the catalyst interfacial activity and relative affinity of the reagents to the Pd active sites. An observed change in the apparent reaction order in styrene for a hydrophilic catalyst suggests that changing catalyst surface wettability from hydrophilic to hydrophobic resulted in a switch from a transport-limited to a kinetic-limited reaction regime.

09 BIOMASS FUELS↗

SU-E-T-382: Evaluation of Clinical Application and Dosimetric Comparison for Treatment Plans of Gamma Knife and CyberKnife for Arteriovenous Malformations

Purpose: To analyze and compare the characteristics of dose distributions between Gamma Knife (GK) and CyberKnife (CK), in treating arteriovenous malformations (AVMs), and evaluate the influences on their clinical applications. Methods: Twenty four patients with AVMs treated with CK of prescribed dose (PD) of 16–25 Gy in single fraction were selected. Each patient’s CT images used for CK treatment planning with contours of targets and critical organs were exported and then loaded into the GK planning system. GK treatment plan with the same PD used in CK was generated for each patient. The metrics for dose comparison between GK and CK included conformity index (CI), gradient index (GI) of 75%, 50% and 25% of the PD, heterogeneity index (HI), volume of brain tissues covered by 10 Gy and 12 Gy, maximum dose to brainstem and beam-on time. Paired Samples t-test was used to analyze these metrics for significance (p value). Results: The CI were 0.744 ± 0.075 (GK) and 0.768 ± 0.086 (CK), p = 0.281. The GI75%, GI50%, and GI25% in GK and CK were 1.735 ± 0.100 and 2.439 ± 0.338 (p < 0.001), 3.169 ± 0.265 and 4.972 ± 0.852 (p < 0.001), and 8.650 ± 0.914 and 14.261 ± 2.476 (p < 0.001). The HI were 0.728 ± 0.072 (GK) and 0.313 ± 0.069 (CK), p < 0.001. There were significant differences both for volume of brain tissues covered by 10 Gy and 12 Gy in GK and CK (p < 0.001). GK had smaller maximum dose to brainstem. CK had shorter beam-on time. Conclusion: GK has similar dose conformity as CK, and has better normal tissue sparing but is less efficient than CK.

60 APPLIED LIFE SCIENCES↗

Solvent-Mediated Crystallization of CH 3 NH 3 SnI 3 Films for Heterojunction Depleted Perovskite Solar Cells

Organo-lead halide perovskite solar cells have gained enormous significance and have now achieved power conversion efficiencies of ~20%. However, the potential toxicity of lead in these systems raises environmental concerns for widespread deployment. In this work we investigate solvent effects on the crystallization of the lead-free methylammonium tin triiodide (CH 3 NH 3 SnI 3 ) perovskite films in a solution growth process. Highly uniform, pinhole-free perovskite films are obtained from a dimethyl sulfoxide (DMSO) solution via a transitional SnI 2 ·3DMSO intermediate phase. This high-quality perovskite film enables the realization of heterojunction depleted solar cells based on mesoporous TiO 2 layer but in the absence of any hole-transporting material with an unprecedented photocurrent up to 21 mA cm –2 . Charge extraction and transient photovoltage decay measurements reveal high carrier densities in the CH 3 NH 3 SnI 3 perovskite device which are one order of magnitude larger than CH 3 NH 3 PbI 3 -based devices but with comparable recombination lifetimes in both devices. The relatively high background dark carrier density of the Sn-based perovskite is responsible for the lower photovoltaic efficiency in comparison to the Pb-based analogues. These results provide important progress toward achieving improved perovskite morphology control in realizing solution-processed highly efficient lead-free perovskite solar cells.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗