Search NASA⌕ Search

SEARCH · Search NASA

Results for “linear response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

On the partitioning strategy based on symmetry transformations

A computational procedure is presented for the analysis of unsymmetric structures. The procedure is based on a modified version of the symmetry-transformation partitioning strategy, in which the response of the structure is approximated by a linear combination of symmetric/antisymmetric response vectors, each obtained by using only a fraction of the degrees of freedom of the original FEM model. The three key elements of the procedure are: (1) mixed (or primitive-variable) formulation with independent shape functions for the different fields; (2) restructuring of the governing discrete equations of the structure into uncoupled sets in the symmetric and antisymmetric response vectors; and (3) a stable and efficient iterative process for generating the response of the structure. The effectiveness of the proposed procedure and its advantages over classical substructuring are demonstrated by means of numerical examples.

Noor, Ahmed K.↗

Multiple Use One-Sided Hypotheses Testing in Univariate Linear Calibration

Consider a normally distributed response variable, related to an explanatory variable through the simple linear regression model. Data obtained on the response variable, corresponding to known values of the explanatory variable (i.e., calibration data), are to be used for testing hypotheses concerning unknown values of the explanatory variable. We consider the problem of testing an unlimited sequence of one sided hypotheses concerning the explanatory variable, using the corresponding sequence of values of the response variable and the same set of calibration data. This is the situation of multiple use of the calibration data. The tests derived in this context are characterized by two types of uncertainties: one uncertainty associated with the sequence of values of the response variable, and a second uncertainty associated with the calibration data. We derive tests based on a condition that incorporates both of these uncertainties. The solution has practical applications in the decision limit problem. We illustrate our results using an example dealing with the estimation of blood alcohol concentration based on breath estimates of the alcohol concentration. In the example, the problem is to test if the unknown blood alcohol concentration of an individual exceeds a threshold that is safe for driving.

Krishnamoorthy, K.↗

A new method for analysis of limit cycle behavior of the NASA/JPL 70-meter antenna axis servos

A piecewise linear method of analyzing the effects of discontinuous nonlinearities on control system performance is described. The limit cycle oscillatory behavior of the system resulting from the nonlinearities is described in terms of a sequence of linear system transient responses. The equations are derived which relate the initial and the terminal conditions of successive transients and the boundary conditions imposed by the non-linearities. The method leads to a convenient computation algorithm for prediction of limit cycle characteristics resulting from discontinuous nonlinearities such as friction, deadzones, and hysteresis.

Hill, R. E.↗

Reaction times to weak test lights

Maloney and Wandell (1984) describe a model of the response of a single visual channel to weak test lights. The initial channel response is a linearly filtered version of the stimulus. The filter output is randomly sampled over time. Each time a sample occurs there is some probability increasing with the magnitude of the sampled response - that a discrete detection event is generated. Maloney and Wandell derive the statistics of the detection events. In this paper a test is conducted of the hypothesis that the reaction time responses to the presence of a weak test light are initiated at the first detection event. This makes it possible to extend the application of the model to lights that are slightly above threshold, but still within the linear operating range of the visual system. A parameter-free prediction of the model proposed by Maloney and Wandell for lights detected by this statistic is tested. The data are in agreement with the prediction.

Wandell, B. A.↗

Reported light in the sleep environment: enhancement of the sleep diary

Light is the primary synchronizing cue for the circadian timing system, capable of exerting robust physiological effects, even with very dim and/or brief photic exposure. Mammals, including humans, are particularly susceptible to light at night. As such, measures of light in the sleeping environment are critical for evaluating sleep health. Sleep diaries provide inexpensive measures of sleep, but do not typically include light information. Four questions probing visual perception of light in the bedtime and waking environments were added to the Consensus Sleep Diary for Morning administration. As part of a lighting intervention study, 18 hospital Labor and Delivery Department personnel completed the sleep diary for 1 week in each of two experimental conditions while wearing Actiwatch devices equipped with photosensors. Diary responses were evaluated against photosensor values from the beginning and end of each rest interval (n=194 rest intervals), as well as against sleep measures, utilizing linear mixed models. Responses to light questions were related to actual light measures at bedtime, controlling for shift type and experimental condition. In addition, subjective light information at bedtime and waking was related to both objective and subjective sleep parameters, with data generally indicating poorer sleep with light in the sleeping environment. Questions addressing perception of light in the sleeping environment may provide a crude yet affordable metric of relative photic intensity. Further, as responses relate to sleep outcomes, subjective light information may yield valuable insights regarding mechanisms and outcomes of clinical significance in sleep and circadian research.

59 BASIC BIOLOGICAL SCIENCES↗

Variability, timescales, and nonlinearity in climate responses to black carbon emissions

Black carbon (BC) particles exert a potentially large warming influence onthe Earth system. Reductions in BC emissions have attracted attention as apossible means to moderate near-term temperature changes. For the first time,we evaluate regional climate responses, nonlinearity, and short-termtransient responses to BC emission perturbations in the Arctic, midlatitudes,and globally based on a comprehensive set of emission-driven experimentsusing the Community Earth System Model (CESM). Surface temperature responsesto BC emissions are complex, with surface warming over land from midlatitudeBC perturbations partially offset by ocean cooling. Climate responses do notscale linearly with emissions. While stronger BC emission perturbations havea higher burden efficiency, their temperature sensitivity is lower. BCimpacts temperature much faster than greenhouse gas forcing, with transienttemperature responses in the Arctic and midlatitudes approaching aquasi-equilibrium state with a timescale of 2–3 years. We find largevariability in BC-induced climate changes due to background model noise. As aresult, removing present-day BC emissions results in discernible surfacetemperature changes for only limited regions of the globe. In order to betterunderstand the climatic impacts of BC emissions, both the drivers ofnonlinear responses and response variability need to be assessed acrossclimate models.

54 ENVIRONMENTAL SCIENCES↗

Nonlinear response of resin matrix laminates using endochronic theory

The nonlinear response of laminated, resin matrix fibrous composites is modeled using orthotropic endochronic theory. The theory is formulated in terms of elastic constants and endochronic parameters characterizing the linear and nonlinear response, respectively, of unidirectional composites. All constants and parameters can be determined from normal (tension and/or compression) and shear tests on unidirectional and off-axis specimens. The nonlinear constitutive response relations for the unidirectional lamina are presented and the procedure for determining constants and parameters from test is described. The results are then used to predict the nonlinear response of unidirectional laminae and angle-ply laminates. Comparison between theory and experiment for compression loading of AS4/3502 graphite-epoxy, angle-ply laminates shows excellent correlation.

Mathison, S. R.↗

Semiclassical nonlinear response functions for coupled anharmonic vibrations

Observables in linear and nonlinear infrared spectroscopy may be computed from vibrational response functions describing nuclear dynamics on a single electronic surface. We demonstrate that the Herman-Kluk (HK) semiclassical approximation to the quantum propagator yields an accurate representation of quantum coherence effects in linear and nonlinear response functions for coupled anharmonic oscillators. A considerable numerical price is paid for this accuracy; the calculation requires a multidimensional integral over a highly oscillatory integrand that also grows without bound as a function of evolution times. The interference among classical trajectories in the HK approximation produces quantization of good action variables. By treating this interference analytically, we develop a mean-trajectory (MT) approximation that requires only the propagation of classical trajectories linked by transitions in action. The MT approximation accurately reproduces coherence effects in response functions of coupled anharmonic oscillators in a regime in which the observables are strongly influenced by these interactions among vibrations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Performance comparison for Barnes model 12-1000, Exotech model 100, and Ideas Inc. Biometer Mark 2

Results of tests show that all channels of all instruments, except channel 3 of the Biometer Mark 2, were stable in response to input signals were linear, and were adequately stable in response to temperature changes. The Biometer Mark 2 is labelled with an inappropriate description of the units measured and the dynamic range is a inappropriate for field measurements causing unnecessarily high fractional errors. This instrument is, therefore, quantization limited. The dynamic range and noise performance of the Model 12-1000 are appropriate for remote sensing field research. The field of view and performance of the Model 100A and the Model 12-1000 are satisfactory. The Biometer Mark 2 has not, as yet, been satisfactorily equipped with an acceptable field of view determining device. Neither the widely used aperture plate nor the 24 deg cone are acceptable.

Robinson, B.↗

Identifying approximate linear models for simple nonlinear systems

This paper addresses the identification (realization) of approximate linear models from response data for certain nonlinear dynamic systems. Response characteristics for several typical nonlinear joints are analyzed mathematically and represented by series expansions. The parameters of the series expansion are then compared with the modal parameters of a linear model identified by the Eigensystem Realization Algorithm. The agreement of the identified model and the analytically derived representation is excellent for the cases studied. Also laboratory data from a model which exhibited stiffening behavior was analyzed using the Eigensystem Realization algorithm and Fast Fourier Transform. The laboratory experiment demonstrated the ability of the technique to recover the model characteristics using real data.

Horta, L. G.↗

Distribution of Chromosome Breakpoints in Human Epithelial Cells Exposed to Low- and High-LET Radiation

Low-and high-LET radiations produced distinct breakpoint distributions. The difference of the breakpoint distributions between low-and high-LET only appeared in break ends involved in interchromosome exchanges. The breakpoint distributions for break ends participating in intrachromosome exchanges were similar. Gene-rich regions do not necessarily have more chromosome breaks. High-LET appeared to produce long live (data not shown) or longer live breaks that can migrate a longer distance before rejoining with other breaks. Domains occupied by different segments of the chromosomes may be responsible for the breakpoint distribution. The dose responses for interchromosomal exchanges were linear in all four exposures. However, the dose response for intrachromosomal exchanges were none linear. Increasing dose of high dose rate exposure (Fe-ions or -rays) increase the fraction of cells with intrachromosome aberrations, whereas increasing dose of low dose rate exposure (neutrons or -rays) does not affect the fraction of cells with intrachromosome aberrations.

Hada, Megumi↗

Modeling and control of thermostatically controlled loads

As the penetration of intermittent energy sources grows substantially, loads will be required to play an increasingly important role in compensating the fast time-scale fluctuations in generated power. Recent numerical modeling of thermostatically controlled loads (TCLs) has demonstrated that such load following is feasible, but analytical models that satisfactorily quantify the aggregate power consumption of a group of TCLs are desired to enable controller design. We develop such a model for the aggregate power response of a homogeneous population of TCLs to uniform variation of all TCL setpoints. A linearized model of the response is derived, and a linear quadratic regulator (LQR) has been designed. Using the TCL setpoint as the control input, the LQR enables aggregate power to track reference signals that exhibit step, ramp and sinusoidal variations. Although much of the work assumes a homogeneous population of TCLs with deterministic dynamics, we also propose a method for probing the dynamics of systems where load characteristics are not well known.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Ball transfer mechanism with polycrystalline diamond bearing support

A ball transfer mechanism for a harmonic drive and linear piston motor is disclosed. The ball transfer mechanism includes a spherical ball and a cylindrical seat portion. The seat portion defines a hemispherical shaped recess with a contour for receiving the ball. The ball transfer mechanism is in an exterior wall of a housing for converting rotary motion to linear motion, driving a linear piston motor. The harmonic drive drives a rotor of the linear piston motor. The harmonic drive includes a hollow cylindrical coupler portion engaging a rotor portion for transferring torque to the rotor portion. Transfer mechanisms disposed along a housing wall of the linear piston motor engage the coupler portion. The coupler portion includes harmonic cam grooves for receiving spherical balls in the ball transfer mechanism that drives rotational motion in the rotor in response to axially linear movement of the piston assembly.

Raymond, David W.↗

Ball transfer mechanism with polycrystalline diamond bearing support

A ball transfer mechanism for a harmonic drive and linear piston motor is disclosed. The ball transfer mechanism includes a spherical ball and a cylindrical seat portion. The seat portion defines a hemispherical shaped recess with a contour for receiving the ball. The ball transfer mechanism is in an exterior wall of a housing for converting rotary motion to linear motion, driving a linear piston motor. The harmonic drive drives a rotor of the linear piston motor. The harmonic drive includes a hollow cylindrical coupler portion engaging a rotor portion for transferring torque to the rotor portion. Transfer mechanisms disposed along a housing wall of the linear piston motor engage the coupler portion. The coupler portion includes harmonic cam grooves for receiving spherical balls in the ball transfer mechanism that drives rotational motion in the rotor in response to axially linear movement of the piston assembly.

Raymond, David W.↗

Impulse-response functions and anthropogenic CO2

Non-linearities in the carbon cycle make the response to atmospheric CO2 perturbations dependent on emission history. We show that even when linear representations of the carbon cycle are used, the calculation of time scales characterizing the removal of excess CO2 depends on past emissions.

Tubiello, Francesco N.↗

A silicon strip detector dose magnifying glass for IMRT dosimetry

Purpose: Intensity modulated radiation therapy (IMRT) allows the delivery of escalated radiation dose to tumor while sparing adjacent critical organs. In doing so, IMRT plans tend to incorporate steep dose gradients at interfaces between the target and the organs at risk. Current quality assurance (QA) verification tools such as 2D diode arrays, are limited by their spatial resolution and conventional films are nonreal time. In this article, the authors describe a novel silicon strip detector (CMRP DMG) of high spatial resolution (200 {mu}m) suitable for measuring the high dose gradients in an IMRT delivery. Methods: A full characterization of the detector was performed, including dose per pulse effect, percent depth dose comparison with Farmer ion chamber measurements, stem effect, dose linearity, uniformity, energy response, angular response, and penumbra measurements. They also present the application of the CMRP DMG in the dosimetric verification of a clinical IMRT plan. Results: The detector response changed by 23% for a 390-fold change in the dose per pulse. A correction function is derived to correct for this effect. The strip detector depth dose curve agrees with the Farmer ion chamber within 0.8%. The stem effect was negligible (0.2%). The dose linearity was excellent for the dose range of 3-300 cGy. A uniformity correction method is described to correct for variations in the individual detector pixel responses. The detector showed an over-response relative to tissue dose at lower photon energies with the maximum dose response at 75 kVp nominal photon energy. Penumbra studies using a Varian Clinac 21EX at 1.5 and 10.0 cm depths were measured to be 2.77 and 3.94 mm for the secondary collimators, 3.52 and 5.60 mm for the multileaf collimator rounded leaf ends, respectively. Point doses measured with the strip detector were compared to doses measured with EBT film and doses predicted by the Philips Pinnacle treatment planning system. The differences were 1.1%{+-}1.8% and 1.0%{+-}1.6%, respectively. They demonstrated the high temporal resolution capability of the detector readout system, which will allow one to investigate the temporal dose pattern of IMRT and volumetric modulated arc therapy (VMAT) deliveries. Conclusions: The CMRP silicon strip detector dose magnifying glass interfaced to a TERA ASIC DAQ system has high spatial and temporal resolution. It is a novel and valuable tool for QA in IMRT dose delivery and for VMAT dose delivery.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nonlinearity and Strain-Rate Dependence in the Deformation Response of Polymer Matrix Composites Modeled

There has been no accurate procedure for modeling the high-speed impact of composite materials, but such an analytical capability will be required in designing reliable lightweight engine-containment systems. The majority of the models in use assume a linear elastic material response that does not vary with strain rate. However, for containment systems, polymer matrix composites incorporating ductile polymers are likely to be used. For such a material, the deformation response is likely to be nonlinear and to vary with strain rate. An analytical model has been developed at the NASA Glenn Research Center at Lewis Field that incorporates both of these features. A set of constitutive equations that was originally developed to analyze the viscoplastic deformation of metals (Ramaswamy-Stouffer equations) was modified to simulate the nonlinear, rate-dependent deformation of polymers. Specifically, the effects of hydrostatic stresses on the inelastic response, which can be significant in polymers, were accounted for by a modification of the definition of the effective stress. The constitutive equations were then incorporated into a composite micromechanics model based on the mechanics of materials theory. This theory predicts the deformation response of a composite material from the properties and behavior of the individual constituents. In this manner, the nonlinear, rate-dependent deformation response of a polymer matrix composite can be predicted.

Goldberg, Robert K.↗