Search NASA⌕ Search

SEARCH · Search NASA

Results for “material testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

The Material Response of PICA-NuSil to a Hypersonic Flow Environment

Phenolic Impregnated Carbon Ablator (PICA) is NASA’s baseline thermal protection system for missions to Mars. PICA is friable; therefore, NuSil ® CV-1144-0 is applied to the surface of flight hardware to mitigate the contamination of spacecraft sensors. NuSil is composed of a polysiloxane resin system that can transform into an oxidation-resistant coating upon heating. Therefore, a pathfinder campaign was conducted at the Hypersonic Materials Environmental Test System (HyMETS) at the NASA Langley Research Center to investigate the material response of instrumented sphere-cone models made from PICA coated with NuSil ® . Analysis of the post-test data is presented and suggests that NuSil ® impacts the material response of test articles subjected to oxidizing atmospheres, as evidenced by a reduction of the measured surface temperature and in-depth temperature response. Finally, a four-step ablation mechanism is proposed based on observations from high-speed video, optical emission spectroscopy, thermal analysis, and post-test surface characterization.

PICA PICA-NuSil Siloxane Silicone↗

Discovery of complex oxides via automated experiments and data science

Significance Automation is accelerating the discovery of useful materials, yet testing even a small fraction of the billions of possible materials for a desired property is beyond the reach of workflows involving resource-intensive property measurements. Due to relationships among composition, structure, and properties, identifying a complex material with one interesting property makes it the proverbial needle in a haystack that merits testing for additional properties. We accelerate materials synthesis and optical characterization by employing physics-aware data science to identify materials for further investigation. With this approach, one does not need high-throughput methods for measuring every material property of interest since a single ultra-high–throughput workflow can guide material selection for other properties, which is a new paradigm for accelerated materials discovery.

36 MATERIALS SCIENCE↗

Environmental charging of spacecraft surfaces: Tests of thermal control materials for use on the global positioning system flight space vehicle. Part 1: Specimens 1 to 5

The NASA/USAF program on Environmental Charging of Spacecraft Surfaces consists of experimental efforts directed toward evaluating the response of materials to the environmental charged particle flux. Samples of thermal blankets and second surface mirrors of the type to be used on the Global Positioning System Flight Space Vehicle were tested to determine their response to electron flux. The primary result observed was that the ground connection of the metal layers of the blanket, as made by the baseline grounding technique using serrated washers and grommets, deteriorated with time at test. The discharges observed on the blankets were the glow type, not the 'lightning' strike observed on past specimens. Testing was performed at ambient laboratory temperatures.

Stevens, N. J.↗

Opposed-Flow Flame Spread in a Narrow Channel Apparatus over Thin PMMA Sheets

Flame spread tests have been conducted over polymethylmethacrylate (PMMA) samples in San Diego State University's Narrow Channel Apparatus (SDSU NCA). The Narrow Channel Apparatus (NCA) has the ability to suppress buoyant flow in horizontally spreading flames, and is currently being investigated as a possible replacement or complement to NASA's current material flammability test standard for non-metallic solids, NASA-STD-(I)-6001B Test 1. The buoyant suppression achieved with a NCA allows for tests to be conducted in a simulated microgravity atmosphere-a characteristic that Test 1 lacks since flames present in Test 1 are buoyantly driven. The SDSU NCA allows for flame spread tests to be conducted with varying opposed flow oxidizer velocities, oxygen percent by volume, and total pressure. Also, since the test sample is placed symmetrically between two confining plates so that there is a gap above and below the sample, this gap can be adjusted. This gap height adjustment allows for a compromise between heat loss from the flame to the confining boundaries and buoyancy suppression achieved by those boundaries. This article explores the effect gap height has on the flame spread rate for 75 μm thick PMMA at 1 atm pressure and 21% oxygen concentration by volume in the SDSU NCA. Flame spread results from the SDSU NCA for thin cellulose fuels have previously been compared to results from tests in actual microgravity at various test conditions with the same sample materials and were found to be in good agreement. This article also presents results from the SDSU NCA for PMMA at 1 atm pressure, opposed oxidizer velocity ranging from 3 to 35 cm/s, oxygen concentration by volume at 21%, 30 %, and 50% and fuel thicknesses of 50 and 75 μm. These results are compared to results obtained in actual microgravity for PMMA obtained at the 4.5s drop tower of MGLAB in Gifu, Japan, and the 5.2s drop tower at NASA's Zero-Gravity Research Facility in Cleveland, OH. This comparison confirms that at 1 atm pressure, the SDSU NCA successfully simulates microgravity for not only thin cellulose fuels, but also for thin PMMA sheets as well. This further supports the idea that the NCA is a viable option to complement or replace NASA's Test 1 for material flammability testing. Tests with thick fuels will be conducted in the future to further characterize the SDSU NCA.

flame spread↗

Comparison of Bolus Materials to Highly Absorbent Polypropylene and Rayon Cloth

This study assesses the utility of a highly absorbent polypropylene and rayon cloth (HAPRC) as a bolus material in radiation therapy. A comparison of various bolus materials used clinically at our center to the test bolus material, water-saturated HAPRC, was conducted. The reproducibility of the physical density was assessed by computerized tomography (CT) scanning the water-saturated HAPRC on a uniform density block phantom on multiple occasions, allowing the cloth to dry fully between subsequent CT scans. The cloth was found to have a consistent physical density between 0.8 and 1.0 g/cm{sup 3}. To evaluate the dosimetric impact of the various bolus materials, metal oxide semiconductor field effect transistor dosimetry measurements were performed for a 6 MV treatment beam on the anterior surface of an anthropomorphic thorax phantom. The ability of the bolus material to conform to an irregular surface was assessed by CT scanning the various bolus materials overlaying the nose of an anthropomorphic head phantom and another irregularly shaped test object. The HAPRC conforms well to irregular contours and is relatively inexpensive compared to Superflab and thermoplastic sheets. Before implementing the material into the clinical setting, an appropriate process for laundering the material should be determined, for hygienic reasons.

61 RADIATION PROTECTION AND DOSIMETRY↗

Affordable Development and Optimization of CERMET Fuels for NTP Ground Testing

CERMET fuel materials for Nuclear Thermal Propulsion (NTP) are currently being developed at NASA's Marshall Space Flight Center. The work is part of NASA's Advanced Space Exploration Systems Nuclear Cryogenic Propulsion Stage (NCPS) Project. The goal of the FY12-14 project is to address critical NTP technology challenges and programmatic issues to establish confidence in the affordability and viability of an NTP system. A key enabling technology for an NCPS system is the fabrication of a stable high temperature nuclear fuel form. Although much of the technology was demonstrated during previous programs, there are currently no qualified fuel materials or processes. The work at MSFC is focused on developing critical materials and process technologies for manufacturing robust, full-scale CERMET fuels. Prototypical samples are being fabricated and tested in flowing hot hydrogen to understand processing and performance relationships. As part of this initial demonstration task, a final full scale element test will be performed to validate robust designs. The next phase of the project will focus on continued development and optimization of the fuel materials to enable future ground testing. The purpose of this paper is to provide a detailed overview of the CERMET fuel materials development plan. The overall CERMET fuel development path is shown in Figure 2. The activities begin prior to ATP for a ground reactor or engine system test and include materials and process optimization, hot hydrogen screening, material property testing, and irradiation testing. The goal of the development is to increase the maturity of the fuel form and reduce risk. One of the main accomplishmens of the current AES FY12-14 project was to develop dedicated laboratories at MSFC for the fabrication and testing of full length fuel elements. This capability will enable affordable, near term development and optimization of the CERMET fuels for future ground testing. Figure 2 provides a timeline of the development and optimization tasks for the AES FY15-17 follow on program.

Hickman, Robert R.↗

Fatigue Strengths of Aircraft Materials: Axial-Load Fatigue Tests on Edge-Notched Sheet Specimens of 2024-T3 and 7075-T6 Aluminum Alloys and of SAE 4130 Steel with Notch Radii of 0.004 and 0.070 inch

The present report gives results of axial-load fatigue tests on notched specimens of three sheet materials: 2024-T3 and 7075-T6 aluminum alloys and normalized SAE 4130 steel. Two edge-notched specimens were designed and tested, each having a theoretical stress-concentration factor K(sub t) = 4.0. The radii of the notches were 0.004 and 0.070 inch. Tests of these specimens were run at two levels of nominal mean stress: 0 and 20,000 psi. Results of these studies extended information previously reported on tests of specimens with varying notch severity. They afford data on the variation of fatigue-strength reduction with notch radius and on the potential usefulness of Neuber's technical stress-concentration factor K(sub n).

Grover, H. J.↗

PATO IHE DDT Test Series

This report describes one aspect of our efforts for qualifying PATO as an IHE. Specifically, we tested PATO against the DDT requirements as defined by LA-UR-15-29238 IHE Material Qualification Test Series, Section 1.1. That section states: “The purpose of the DDT test is to demonstrate that an IHE material will not undergo deflagration-to-detonation transition (DDT) under stockpile-relevant conditions of scale, confinement, and material condition. Inherent in this test design is the assumption that ignition does occur, with the onset of deflagration. The test design will incorporate large margins and replicates to account for the stochastic nature of DDT events.” Along with the primary goal of qualifying PATO, this is the first time this test standard has been executed, as such, we are ‘testing the test’ by providing details of execution, pragmatic details that could be improved, and feedback regarding scientific issues.

36 MATERIALS SCIENCE↗

Sources of error in detonation calorimeters and error analysis for neat 2,4,6-triamino-1,3,5- trinitrobenzene (TATB)

Here, a calorimeter for measuring heats of detonation at Lawrence Livermore National Laboratory is described. A calibration precision of 0.2 % at the 95 % confidence interval (CI) is reported. Sources of uncertainty are discussed, including nonequivalent sources, which are those arising from differences between calibration and experimental tests. The systematic error due to nonequivalent sources is bounded to 0.19–0.22 % of the measured heat for a standard detonation test where the confinement material is gold. The recommendation is to correct for the systematic error by adding 0.19 % to the reported value and adding 0.03 % to the uncertainty. It is demonstrated that the precision of a detonation test is variable with testing duration because a source of uncertainty resides in the thermodynamic correction factor k6, which accounts for the contribution to heat by stirring; the generated power is additive and therefore highly impacted by total test time. The relative proportion also varies with the magnitude of heat release and sample size, adding variance to the weight of the error arising from the correction factor. A full error analysis based on the described sources of uncertainty is developed. The methodology is applied to a test series on neat 2,4,6-triamino-1,3,5- trinitrobenzene (TATB), demonstrating an ultimate precision of 0.7 % (single test) for materials testing and a relative standard deviation of 1.8 %.

47 OTHER INSTRUMENTATION↗

Stress corrosion evaluation of HP 9Ni-4Co-0.30C steel plate welds

A stress corrosion cracking (SCC) investigation was conducted on HP 9Ni-4Co-0.30C steel plate welds (welded by using straight polarity plasma arc and HP 9Ni-4Co-0.20C weld wire) since this material is being considered for use in the Advanced Solid Rocket Motor (ASRM) program. Prior to the welding, the material was double tempered at 538 C (1,000 F). After welding, only part of the material was stress relieved at 510 C (950 F) for 3 h. Round tensile specimens obtained from nonstress-relieved material were tested in 100-percent relative humidity at 38 C (100 F), in 3.5-percent NaCl alternate immersion, and in 5-percent salt spray at 35 C (95 F). Specimens obtained from stress-relieved material were tested in alternate immersion. The stress levels were 50, 75, and 90 percent of the corresponding 0.2-percent yield strength (YS). All the nonstress-relieved specimens exposed to salt spray and alternate immersion failed. Stress-relieved specimens (exposed to alternate immersion) failed at 75 and 90 percent of YS. No failures occurred at 50 percent of YS in the stress-relieved specimens which indicates a beneficial effect of the stress relief on the SCC resistance of these welds. The stress relief also had a positive effect on the mechanical properties of the welds (the most important being an increase of 21 percent on the YS). Under the conditions of these tests, the straight polarity plasma are welded HP 9Ni4Co-0.30C steel plate was found highly susceptible to SCC in the nonstress-relieved condition. This susceptibility to SCC was reduced by stress relieving.

Torres, Pablo D.↗

Contamination control in hybrid microelectronic modules. Part 2: Selection and evaluation of coating materials

The selection, test, and evaluation of organic coating materials for contamination control in hybrid circuits is reported. The coatings were evaluated to determine their suitability for use as a conformal coating over the hybrid microcircuit (including chips and wire bonds) inside a hermetically sealed package. Evaluations included ease of coating application and repair and effect on thin film and thick film resistors, beam leads, wire bonds, transistor chips, and capacitor chips. The coatings were also tested for such properties as insulation resistance, voltage breakdown strength, and capability of immobilizing loose particles inside the packages. The selected coatings were found to be electrically, mechanically, and chemically compatible with all components and materials normally used in hybrid microcircuits.

Himmel, R. P.↗

Free-Roller Versus Fixed-Roller Fixtures in Flexure Testing of Advanced Ceramic Materials

The error associated with strength measurements made with fixed-roller and V-grooved roller figures was studied with a variety of roller and figure material combinations. Both the fixed-roller and the V-grooved fixtures yielded an error in stress of about 4 to 7%. They also exhibited an appreciable amount of load strain hysteresis. Dynamic fatigue testing of 96 wt.% alumina verified the error: the fatigue strength was overestimated by 7 to 9% for the fixed roller configuration. The source of error is exclusively attributed to friction between the rollers and the specimen surface, as verified by previous investigators.

Salem, Jonathan A.↗

Initial materials evaluation of the thermal control surfaces experiment (S0069)

The Thermal Control Surface Experiment (TCSE) was flown on the NASA Long Duration Exposure Facility (LDEF) with the basic objective of determining the effects of the near-earth orbital environment and the LDEF induced environment on spacecraft thermal control surfaces. The TCSE was a comprehensive experiment that combined in-space measurements with extensive post-flight analyses of thermal control surfaces to determine the effects of exposure to the low earth orbit space environment. The TCSE is the first space experiment to measure the optical properties of thermal control surfaces the way they are routinely measured in the laboratory. The specific mission objectives of the TCSE were to: (1) determine the effects of the natural and induced space environment on thermal control surfaces; (2) provide in-space performance data on thermal control surfaces; (3) provide in-space comparison to ground-based environmental testing of materials; and (4) develop and prove instrumentation to perform in-space optical testing of materials. Various aspects of the experiment are discussed.

Donald R. Wilkes↗

High-Pressure Oxygen Test Evaluations

The relevance of impact sensitivity testing to the development of the space shuttle main engine is discussed in the light of the special requirements for the engine. The background and history of the evolution of liquid and gaseous oxygen testing techniques and philosophy is discussed also. The parameters critical to reliable testing are treated in considerable detail, and test apparatus and procedures are described and discussed. Materials threshold sensitivity determination procedures are considered and a decision logic diagram for sensitivity threshold determination was plotted. Finally, high-pressure materials sensitivity test data are given for selected metallic and nonmetallic materials.

Schwinghamer, R. J.↗

Ballistic Impact Testing of Aluminum 2024 and Titanium 6Al-4V for Material Model Development

An experimental program is underway to develop a consistent set of material property and impact test data, and failure analysis, for a variety of materials that can be used to develop improved impact failure and deformation models. Unique features of this set of data are that all material property information and impact test results are obtained using identical materials, the test methods and procedures are extensively documented and all of the raw data is available. This report describes ballistic impact testing which has been conducted on aluminum (Al) 2024 and titanium (Ti) 6Al-4vanadium (V) sheet and plate samples of different thicknesses and with different types of projectiles, one a regular cylinder and one with a more complex geometry incorporating features representative of a jet engine fan blade.

Pereira, J. Michael↗

Ground Testing of the MISSE-16 Materials

External spacecraft materials play an important role in satellite protection from the harsh space environment. Research has shown that the physical, chemical, and optical properties of matter change continuously as a result of exposure to solar radiation and aggressive chemical species produced in Earth’s upper atmosphere. Thorough knowledge of the material properties evolution throughout a planned mission lifetime helps to improve the reliability of spacecraft. Moreover, the establishment of correlation factors between true space exposure and accelerated space weather experiments at ground facilities enables accurate prediction of on-orbit material performance based on laboratory-based testing. The presented work aims to evaluate the radiation effects of low Earth orbit (LEO) environment, namely, exposure to the high-energy electrons and atomic oxygen (AO), of heritage and novel spacecraft materials selection. The studied materials represent the “flight duplicates” of samples that are launched as a part of the 16th Materials International Space Station Experiment Flight Facility (MISSE-FF) mission in 2022.

Elena A. Plis↗

Engineering Development Program of a Closed Aluminum-Oxygen Semi-cell System for an Unmanned Underwater Vehicle: An Update

Most emerging unmanned undersea vehicle (UUV) missions require significantly longer range and endurance than is achievable with existing battery technology. The Aluminum-Oxygen (Al-O2) semi-cell is a candidate technology capable of providing a significant improvement in endurance compared to the silver-zinc battery technology currently in use in UUVs and compares favorably to other proposed UUV power systems not only in performance, but also in safety and logistics. An Al-O2 semi-cell system is under development, consisting of a cell stack, gas management, oxygen storage, electrolyte management coolant and controller subsystems. It is designed to replace the existing silver-zinc battery and meet existing weight, volume, electrical and thermal requirements, therefore minimizing modification to the UUV. A detailed system design is complete. A component and material endurance test to evaluate compatibility and reliability of various materials and components is complete. Sub=scale (short stack) system testing is complete. A full-scale demonstration unit is now under construction for testing in the second half of 1995. The full scale demonstration test will simulate environmental conditions of the operational system. This paper summarizes the results of the extensive short stack and endurance test programs, describes the plan for full-scale testing, and concludes with a brief discussion of future directions for this technology.

Gregg, Dane W.↗

An AGARD supplemental test programme on the behaviour of short cracks under constant amplitude and aircraft spectrum loading

An AGARD Supplemental Test Program on the growth of short fatigue cracks was conducted to allow testing of various materials and loading conditions that were of interest. Twenty-two participants from ten laboratories in eight countries contributed to the supplemental test program. The objective is to review the supplemental test program and to summarize the results obtained from all laboratories. The materials tested in the supplemental program were: 2024-T3 and 7075-T6 aluminum alloys, 2090-T8E41 aluminum-lithium alloy, Ti6Al4V titanium alloy, and 4340 steel. Tests on single-edge-notch-tension specimens were conducted under several constant-amplitude loading conditions and spectrum loading conditions (FALSTAFF, Inverted FALSTAFF, GAUSSIAN, TWIST, Felix, and the Fokker 100 spectra). The plastic-replica method was used to measure the growth of short cracks at the notch root. The results from the supplemental test program show good agreement among the several laboratories who measured short-crack growth rates on the aluminum-lithium alloy.

Edwards, P. R.↗