Search NASA⌕ Search

SEARCH · Search NASA

Results for “modulating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

Biogenic triamine and tetraamine activate core catalytic ability of Tetrahymena group I ribozyme in the absence of its large activator module

Highlights: • Biogenic triamine and tetraamine efficiently activated the ∆P5 ribozyme. • Spermine (tetraamine) modestly inhibited the full-length Tetrahymena ribozyme. • Polyamines are promising small molecule modulators to activate and possibly inhibit the core catalytic ability of group I ribozymes. Group I intron ribozymes share common core elements that form a three-dimensional structure responsible for their catalytic activity. This core structure is unstable without assistance from additional factors that stabilize its tertiary structure. We examined biogenic triamine and tetraamine and also their fragments for their abilities to stabilize a structurally unstable group I ribozyme, ΔP5 ribozyme, derived from the Tetrahymena group I intron ribozyme by deleting its large activator module. Biogenic triamine (spermidine) and tetraamine (spermine) efficiently activated the ΔP5 ribozyme under conditions where the ribozyme was virtually inactive. These observations suggested that polyamines are promising small molecule modulators to activate and possibly inhibit the core catalytic ability of group I ribozymes.

60 APPLIED LIFE SCIENCES↗

Intra-catalyst CH 4 oxidation pathways on a Pd/Al 2 O 3 /CeZrO x -based commercial catalyst and implications on NO x conversion profiles for a natural gas vehicle exhaust under lambda modulation

The performance of a three-way catalyst (TWC) in natural gas-powered vehicles is enhanced by periodic changes in air-to-fuel ratio (λ-modulation). The reaction networks and sequences inside the catalyst that facilitate such enhanced performance have not been extensively investigated. Here, this work applied intra-catalyst measurements (SpaciMS) to analyze the transient spatiotemporal gas concentrations inside a Pd-based TWC to establish relationships between CH 4 , NO x , CO and H 2 conversion pathways. Steam reforming and partial oxidation were revealed to be the main CH 4 conversion routes. The cyclic rich-lean conditions combined with the oxygen storage capacity (OSC) of the TWC generate reduced and oxidized zones that are constantly moving within the catalyst, changing the dominant chemical reactions occurring on the surface. In the reduced zones, OSC is depleted while CH 4 is converted through steam reforming and NO x is converted through reactions with H 2 , CO, and other surface-bound reducing fragments formed by CH 4 conversion. In the oxidized zones, OSC is replenished, CH 4 is converted by partial oxidation, and H 2 , CO, and NH 3 are oxidized. The length of lean-rich phases impacts the catalyst performance significantly; too short or too long of a rich or lean phase can lower the overall conversion of reactive species. An inhibition of CH 4 conversion was observed during the rich phase possibly due to CO-poisoning of active sites. The intra-catalyst measurements revealed that the catalyst consists of three distinct reaction zones and their lengths vary with modulation conditions. Various modulation frequencies, amplitudes, λ-centers, and temperatures were investigated which allowed an understanding of how these parameters affect the reaction zones and catalyst utilization. Understandings from this work can enable adaptive λ-control strategies to optimize the overall TWC performance over a range of vehicle operating conditions.

Lean-Rich cycling↗

The MOOSE fluid properties module

The Fluid Properties module within the Multiphysics Object-Oriented Simulation Environment (MOOSE) is used to compute fluid properties for numerous applications, ranging from nuclear reactor thermal hydraulics to geothermal energy. Those applications drove the development of the module to enable numerous different fluid equations of states, property lookups with primitive and conserved flow variable to cater to pressure and density-driven solvers, and an object-oriented design facilitating expansion and maintenance. Each fluid property is implemented in its own class but inherits capabilities such as automatic differentiation, automated out-of-bounds handling or variable conversion capabilities. Here, this paper presents the module, its design, its user and developer interface, its content in terms of fluids and properties, and several of its applications showing its major role in the MOOSE simulation ecosystem.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Advancements in conventional and 3D printed feed spacers in membrane modules

Plate & frame and spiral-wound modules are used for gas separation, pervaporation, reverse osmosis, nanofiltration, ultrafiltration, microfiltration, electro-dialysis, electro-deionization, membrane distillation and forward osmosis membrane processes. Feed channel spacers are an integral part of both module types – providing mechanical support for a cross-flow channel through the module and, in most cases, promoting mixing to enhance mass transfer to reduce concentration polarization and fouling. However, enhanced mass transfer comes at a cost of increased hydraulic pressure losses and stagnant zones wherever a spacer filament touches a membrane surface. Further, these stagnant zones exacerbate membrane fouling and make cleaning more difficult. Efforts to improve feed spacer performance largely focus on adjusting the chemistry or geometry of the spacer to mitigate these challenges. Additive manufacturing (i.e. 3D printing) offers new degrees of freedom in feed spacer design and production, which opens up a new area of research in membrane technology. This review critically assesses the peer-reviewed literature on conventional net- or mesh-style feed spacers in addition to various novel spacer geometries and chemistries produced via 3D printing. We further review and evaluate conventional spacer manufacturing methods and discuss advantages and disadvantages of 3D printed spacers.

3D printing↗

Features of mechanical behavior of EV battery modules under high deformation rate

Here, we observe changes in material behavior of electric vehicle (EV) Li-ion battery cell modules when the loading speed increases from quasi-static to high speed (close to 1 m/s). A series of out-of-plane indentation experiments were performed on stacks of pouch cells placed in the specially designed enclosure to represent conditions in battery modules. Over one hundred of large format automotive pouch cells were tested under displacement rates differing by orders of magnitude. The details of internal failure were studied by X-ray tomography (XCT). We determine a shift in the force–displacement response from a parabolic behavior characteristic of particulate materials under compression to the response normal of fully dense materials with yield point. This shift is associated with dynamic effects in active materials which result in deep propagation of damage into the battery module, despite the fact that the internal short circuit is triggered when the displacement of the indenter is one half of that under the slow displacement rate.

25 ENERGY STORAGE↗

Advanced diagnostics to evaluate heterogeneity in lithium-ion battery modules

Battery packs for electric and stationary applications experience varied operating conditions, including abuse—e.g., fast charging, overcharging, thermal, vibration, shock, etc.—throughout their lifetimes. Innovative diagnostic tools and algorithms that go beyond single cells and deal with modules and packs are essential for early detection of off-normal issues. High-resolution tools with known detection limits are key to developing appropriate mitigation strategies. With the advent of rapid impedance spectroscopy that can generate a broadband impedance spectrum in ~10 sec, the case for impedance-based diagnostics that can be readily aligned with other methods, such as incremental capacity or dQ.dV -1 , has become promising. This study used the aforementioned diagnostic methods to identify realistic in-vehicle battery abnormalities (e.g., localized self-discharge and non-uniform aging), in series (up to 10S) and parallel (4P) strings, using 16 Ah graphite/NMC cells. The impedance-based diagnostic is found to be sensitive to the string size and state. Depending on the type of abnormality, detection frequency varied. The dQ.dV -1 method showed the potential to detect long-term aging-related heterogeneity in modules. In general, both the impedance and dQ.dV -1 methods were able to detect series strings’ abnormalities, but struggled to find those issues within parallel modules.

25 ENERGY STORAGE↗

Measurement of High-temperature Thermophysical Properties of Bulk and Coatings Using Modulated Photothermal Radiometry

This paper presents the development of instrumentation for the measurement of high-temperature thermal conductivity of bulk and coatings using a modulated photothermal radiometry (MPR) method, where a sample is heated by an intensity-modulated laser to probe into different layers of the sample. While MPR has been previously established, most of the previous studies only focus on the measurement at room temperature. The MPR has not been well studied for measurements of bulk and coating materials at high temperatures, which are increasingly important for a multitude of applications, such as materials used in the concentrating solar power (CSP) plants and the nuclear reactors. MPR is a non-contact technique that utilizes the intrinsic thermal emission from the specimens for thermometry, which is favorable for measurements at high temperatures in harsh environment. The authors designed and utilized a sample holder suitable for high temperature measurement up to 973 K with good temperature uniformity within the sample. The high-temperature MPR setup was validated by measuring bulk materials with known thermal conductivity. The setup and technique were then extended to the measurement of black solar-absorbing coatings of 10 to 50 μm thick on various substrates by modulating the frequency of the laser heating beam and the thermal penetration depth. Here, the studies showed that thermal conductivities of typical solar-absorbing coatings are 0.4 ~ 0.8 W m -1 K -1 , indicating a possibly large temperature drop within the coating under high solar irradiation flux, such as over 1000-sun for central solar towers in CSP plants.

14 SOLAR ENERGY↗

Parameter extraction approaches for compact modeling of thermoelectric modules

Thermoelectric (TE) cooling has experienced rapid advancements with the foundational understanding of TE materials. TE modules, compact and lightweight devices, have become the prevalent approach for implementing TE technologies. Accurately quantifying TE physical parameters (Seebeck coefficient α, thermal conductivity κ, and thermal resistance ρ) is challenging due to the dynamic temperature changes in operation. Furthermore, extracting lumped property parameters is crucial for designing energy systems using TE modules. Existing research has several limitations, such as lack of comparative analysis between prevalent formulae, reliance on potentially inaccurate vendor-supplied data, disregard for fundamental assumptions, and absence of empirical measurements. Further, this study addresses these gaps by conducting TE material characterization, comparing three existing formulae using vendor datasheets, designing a laboratory test facility for model validation and refinement, and outlining a structured data extraction procedure. The study's novelty lies in multiple key contributions: (1) a detailed comparative analysis of existing formulae for extracting TE property parameter; (2) executing experimental work in a laboratory setting to validate the model and elucidate its limitations; (3) highlighting potential risks; (4) clarifying possible assumptions from both material and engineering perspectives; and (5) considering temperature differential impacts. This comprehensive approach addresses the current research gaps and provides valuable insights into the design and application of TE modules in various energy systems.

36 MATERIALS SCIENCE↗

Image-Guided Intensity-Modulated Photon Radiotherapy Using Multifractionated Regimen to Paraspinal Chordomas and Rare Sarcomas

Purpose: Image-guided intensity-modulated radiotherapy enables delivery of high-dose radiation to tumors close to the spinal cord. We report our experience with multifractionated regimens using image-guided intensity-modulated radiotherapy to treat gross paraspinal disease to doses beyond cord tolerance. Methods and Materials: We performed a retrospective review of 27 consecutive patients with partially resected or unresectable paraspinal tumors irradiated to >5,300 cGy in standard fractionation. Results: The median follow-up was 17.4 months (range, 2.1-47.3). Eighteen sarcomas, seven chordomas, and two ependymomas were treated. The median dose to the planning target volume was 6,600 cGy (range, 5,396-7,080) in 180- or 200-cGy fractions. The median planning target volume was 164 cm{sup 3} (range, 29-1,116). Seven patients developed recurrence at the treatment site (26%), and 6 of these patients had high-grade tumors. Three patients with recurrence had metastatic disease at the time of radiotherapy. The 2-year local control rate was 65%, and the 2-year overall survival rate was 79%. Of the 5 patients who died, 4 had metastatic disease at death. Twenty-three patients (84%) reported either no pain or improved pain at the last follow-up visit. Sixteen patients discontinued narcotic use after treatment (62.5%). Twenty-three patients (89%) had a stable or improved American Spine Injury Association score at the last follow-up visit. No patient experienced radiation-induced myelopathy. Conclusions: The dose to paraspinal tumors has traditionally been limited to respect cord tolerance. With image-guided intensity-modulated radiotherapy, greater doses of radiation delivered in multiple fractions can be prescribed with excellent target coverage, effective palliation, and acceptable toxicity and local control.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Long-Term Outcome After Static Intensity-Modulated Total Body Radiotherapy Using Compensators Stratified by Pediatric and Adult Cohorts

Purpose: To report the long-term outcome after total body irradiation with intensity-modulating compensators and allogeneic/autologous transplantation, especially in terms of therapy-related toxicity in pediatric and adult cohorts. Methods and Materials: A total of 257 consecutive patients (40 children and 217 adults) have been treated since 1983 with TBI using static intensity-modulated radiotherapy for hematologic malignancies. The total dose of 12 Gy was applied in six fractions within 3 days before allogeneic (n = 174) or autologous (n = 83) transplantation. The median follow-up was 9.2 years. Results: The 5-year overall survival rate was 47.9% (49.8% for the adults and 37.5% for the children, p = 0.171). The 5-year tumor-related mortality rate was 23%, and the 5-year treatment-related mortality rate 29.2% (29.5% in the adults and 27.5% in the pediatric patients). Interstitial pneumonitis developed in 28 (10.9%) of 257 patients and in 12.5% of the pediatric cohort. The interstitial pneumonitis rate was 25% in pediatric patients treated with a 12-Gy lung dose compared with 4.2% for those treated to an 11-Gy lung dose. The overall survival rate stratified by lung dose was 26.7% for 12 Gy and 52.4% for 11 Gy (p = 0.001). The incidence of veno-occlusive disease and cataract was 5.8% and 6.6% in all patients and 12.5% and 15% in the pediatric patients, respectively (p < 0.05). Secondary malignancies were found in 4.3% of all patients, all in the adult cohort at transplantation. Conclusion: Static intensity-modulated total body irradiation with a total dose of 12 Gy before allogeneic/autologous transplantation is a successful treatment with good long-term outcome and acceptable therapy-related toxicities. Constraining the lung dose to 11 Gy substantially lowered the actuarial treatment-related mortality. This effect was especially striking in the pediatric patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High-Dose, Single-Fraction Image-Guided Intensity-Modulated Radiotherapy for Metastatic Spinal Lesions

Purpose: To report tumor control and toxicity for patients treated with image-guided intensity-modulated radiotherapy (RT) for spinal metastases with high-dose single-fraction RT. Methods and Materials: A total of 103 consecutive spinal metastases in 93 patients without high-grade epidural spinal cord compression were treated with image-guided intensity-modulated RT to doses of 18-24 Gy (median, 24 Gy) in a single fraction between 2003 and 2006. The spinal cord dose was limited to a 14-Gy maximal dose. The patients were prospectively examined every 3-4 months with clinical assessment and cross-sectional imaging. Results: The overall actuarial local control rate was 90% (local failure developed in 7 patients) at a median follow-up of 15 months (range, 2-45 months). The median time to local failure was 9 months (range, 2-15 months) from the time of treatment. Of the 93 patients, 37 died. The median overall survival was 15 months. In all cases, death was from progression of systemic disease and not local failure. The histologic type was not a statistically significant predictor of survival or local control. The radiation dose was a significant predictor of local control (p = 0.03). All patients without local failure also reported durable symptom palliation. Acute toxicity was mild (Grade 1-2). No case of radiculopathy or myelopathy has developed. Conclusion: High-dose, single-fraction image-guided intensity-modulated RT is a noninvasive intervention that appears to be safe and very effective palliation for patients with spinal metastases, with minimal negative effects on quality of life and a high probability of tumor control.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Hypofractionated Accelerated Radiotherapy Using Concomitant Intensity-Modulated Radiotherapy Boost Technique for Localized High-Risk Prostate Cancer: Acute Toxicity Results

Purpose: To evaluate the acute toxicities of hypofractionated accelerated radiotherapy (RT) using a concomitant intensity-modulated RT boost in conjunction with elective pelvic nodal irradiation for high-risk prostate cancer. Methods and Materials: This report focused on 66 patients entered into this prospective Phase I study. The eligible patients had clinically localized prostate cancer with at least one of the following high-risk features (Stage T3, Gleason score {>=}8, or prostate-specific antigen level >20 ng/mL). Patients were treated with 45 Gy in 25 fractions to the pelvic lymph nodes using a conventional four-field technique. A concomitant intensity-modulated radiotherapy boost of 22.5 Gy in 25 fractions was delivered to the prostate. Thus, the prostate received 67.5 Gy in 25 fractions within 5 weeks. Next, the patients underwent 3 years of adjuvant androgen ablative therapy. Acute toxicities were assessed using the Common Terminology Criteria for Adverse Events, version 3.0, weekly during treatment and at 3 months after RT. Results: The median patient age was 71 years. The median pretreatment prostate-specific antigen level and Gleason score was 18.7 ng/L and 8, respectively. Grade 1-2 genitourinary and gastrointestinal toxicities were common during RT but most had settled at 3 months after treatment. Only 5 patients had acute Grade 3 genitourinary toxicity, in the form of urinary incontinence (n = 1), urinary frequency/urgency (n = 3), and urinary retention (n = 1). None of the patients developed Grade 3 or greater gastrointestinal or Grade 4 or greater genitourinary toxicity. Conclusion: The results of the present study have indicated that hypofractionated accelerated RT with a concomitant intensity-modulated RT boost and pelvic nodal irradiation is feasible with acceptable acute toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Intensity-Modulated Radiotherapy as Primary Therapy for Prostate Cancer: Report on Acute Toxicity After Dose Escalation With Simultaneous Integrated Boost to Intraprostatic Lesion

Purpose: To report on the acute toxicity of a third escalation level using intensity-modulated radiotherapy for prostate cancer (PCa) and the acute toxicity resulting from delivery of a simultaneous integrated boost (SIB) to an intraprostatic lesion (IPL) detected on magnetic resonance imaging (MRI), with or without spectroscopy. Methods and Materials: Between January 2002 and March 2007, we treated 230 patients with intensity-modulated radiotherapy to a third escalation level as primary therapy for prostate cancer. If an IPL (defined by MRI or MRI plus spectroscopy) was present, a SIB was delivered to the IPL. To report on acute toxicity, patients were seen weekly during treatment and 1 and 3 months after treatment. Toxicity was scored using the Radiation Therapy Oncology Group toxicity scale, supplemented by an in-house-developed scoring system. Results: The median dose to the planning target volume was 78 Gy. An IPL was found in 118 patients. The median dose to the MRI-detected IPL and MRI plus spectroscopy-detected IPL was 81 Gy and 82 Gy, respectively. No Grade 3 or 4 acute gastrointestinal toxicity developed. Grade 2 acute gastrointestinal toxicity was present in 26 patients (11%). Grade 3 genitourinary toxicity was present in 15 patients (7%), and 95 patients developed Grade 2 acute genitourinary toxicity (41%). No statistically significant increase was found in Grade 2-3 acute gastrointestinal or genitourinary toxicity after a SIB to an IPL. Conclusion: The results of our study have shown that treatment-induced acute toxicity remains low when intensity-modulated radiotherapy to 80 Gy as primary therapy for prostate cancer is used. In addition, a SIB to an IPL did not increase the severity or incidence of acute toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dose to Larynx Predicts for Swallowing Complications After Intensity-Modulated Radiotherapy

Purpose: To evaluate early swallowing after intensity-modulated radiotherapy for head and neck squamous cell carcinoma and determine factors correlating with aspiration and/or stricture. Methods and Materials: Consecutive patients treated with intensity-modulated radiotherapy with or without chemotherapy between September 2004 and August 2006 at the Dana Farber Cancer Institute/Brigham and Women's Hospital were evaluated with institutional review board approval. Patients underwent swallowing evaluation after completion of therapy; including video swallow studies. The clinical- and treatment-related variables were examined for correlation with aspiration or strictures, as well as doses to the larynx, pharyngeal constrictor muscles, and cervical esophagus. The correlation was assessed with logistic regression analysis. Results: A total of 96 patients were evaluated. Their median age was 55 years, and 79 (82%) were men. The primary site of cancer was the oropharynx in 43, hypopharynx/larynx in 17, oral cavity in 13, nasopharynx in 11, maxillary sinus in 2, and unknown primary in 10. Of the 96 patients, 85% underwent definitive RT and 15% postoperative RT. Also, 28 patients underwent induction chemotherapy followed by concurrent chemotherapy, 59 received concurrent chemotherapy, and 9 patients underwent RT alone. The median follow-up was 10 months. Of the 96 patients, 31 (32%) had clinically significant aspiration and 36 (37%) developed a stricture. The radiation dose-volume metrics, including the volume of the larynx receiving {>=}50 Gy (p = 0.04 and p = 0.03, respectively) and volume of the inferior constrictor receiving {>=}50 Gy (p = 0.05 and p = 0.02, respectively) were significantly associated with both aspiration and stricture. The mean larynx dose correlated with aspiration (p = 0.003). Smoking history was the only clinical factor to correlate with stricture (p = 0.05) but not aspiration. Conclusion: Aspiration and stricture are common side effects after intensity-modulated radiotherapy for head-and-neck squamous cell carcinoma. The dose given to the larynx and inferior constrictors correlated with these side effects.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The M. D. Anderson Symptom Inventory-Head and Neck Module, a Patient-Reported Outcome Instrument, Accurately Predicts the Severity of Radiation-Induced Mucositis

Purpose: To compare the M. D. Anderson Symptom Inventory-Head and Neck (MDASI-HN) module, a symptom burden instrument, with the Functional Assessment of Cancer Therapy-Head and Neck (FACT-HN) module, a quality-of-life instrument, for the assessment of mucositis in patients with head-and-neck cancer treated with radiotherapy and to identify the most distressing symptoms from the patient's perspective. Methods and Materials: Consecutive patients with head-and-neck cancer (n = 134) completed the MDASI-HN and FACT-HN before radiotherapy (time 1) and after 6 weeks of radiotherapy or chemoradiotherapy (time 2). The mean global and subscale scores for each instrument were compared with the objective mucositis scores determined from the National Cancer Institute Common Terminology Criteria for Adverse Events, version 3.0. Results: The global and subscale scores for each instrument showed highly significant changes from time 1 to time 2 and a significant correlation with the objective mucositis scores at time 2. Only the MDASI scores, however, were significant predictors of objective Common Terminology Criteria for Adverse Events mucositis scores on multivariate regression analysis (standardized regression coefficient, 0.355 for the global score and 0.310 for the head-and-neck cancer-specific score). Most of the moderate and severe symptoms associated with mucositis as identified on the MDASI-HN are not present on the FACT-HN. Conclusion: Both the MDASI-HN and FACT-HN modules can predict the mucositis scores. However, the MDASI-HN, a symptom burden instrument, was more closely associated with the severity of radiation-induced mucositis than the FACT-HN on multivariate regression analysis. This greater association was most likely related to the inclusion of a greater number of face-valid mucositis-related items in the MDASI-HN compared with the FACT-HN.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Hypofractionated Intensity-Modulated Arc Therapy for Lymph Node Metastasized Prostate Cancer

Purpose: To determine the planning results and acute toxicity after hypofractionated intensity-modulated arc radiotherapy and androgen deprivation for lymph node metastasized (Stage N1) prostate cancer. Methods and Materials: A total of 31 patients with Stage T1-T4N1M0 prostate cancer were treated with intensity-modulated arc radiotherapy and 3 years of androgen deprivation as primary treatment. The clinical target volume (CTV{sub p}) was the prostate and seminal vesicles. Elective lymph node areas ({sub e}) were delineated and expanded by 2 mm to create the CTV{sub e}. The planning target volumes (PTV{sub p} and PTV{sub e}) were created using a three-dimensional expansion of the CTV{sub p} and CTV{sub e}, respectively, of 7 mm. A median dose of 69.3 Gy and 50 Gy was prescribed to the PTV{sub p} and PTV{sub e} respectively, to be delivered in 25 fractions. Upper and lower gastrointestinal toxicity was scored using the Radiation Therapy Oncology Group toxicity and radiotherapy-induced lower intestinal toxicity scoring system. Genitourinary toxicity was scored using a combined Radiation Therapy Oncology Group, LENT-SOMA (late effects normal tissue-subjective, objective, management, analytic), and Common Toxicity Criteria toxicity scoring system. Results: The median follow-up time was 3 months. The mean prescription dose to the CTV{sub p} and PTV{sub p} was 70.4 Gy and 68.6 Gy, respectively. The minimal dose to the CTV{sub e} and PTV{sub e} was 49.0 Gy and 47.0 Gy, respectively. No acute Grade 2 or greater gastrointestinal toxicity occurred. Fourteen patients developed acute Grade 2 lower gastrointestinal toxicity. Acute Grade 3 and 2 genitourinary toxicity developed in 2 and 14 patients, respectively. Conclusion: The results of our study have shown that hypofractionated intensity-modulated arc radiotherapy as primary therapy for N1 prostate cancer is feasible with low toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Clinical Experience With Image-Guided Radiotherapy in an Accelerated Partial Breast Intensity-Modulated Radiotherapy Protocol

Purpose: To explore the feasibility of fiducial markers for the use of image-guided radiotherapy (IGRT) in an accelerated partial breast intensity modulated radiotherapy protocol. Methods and Materials: Nineteen patients consented to an institutional review board approved protocol of accelerated partial breast intensity-modulated radiotherapy with fiducial marker placement and treatment with IGRT. Patients (1 patient with bilateral breast cancer; 20 total breasts) underwent ultrasound guided implantation of three 1.2- x 3-mm gold markers placed around the surgical cavity. For each patient, table shifts (inferior/superior, right/left lateral, and anterior/posterior) and minimum, maximum, mean error with standard deviation were recorded for each of the 10 BID treatments. The dose contribution of daily orthogonal films was also examined. Results: All IGRT patients underwent successful marker placement. In all, 200 IGRT treatment sessions were performed. The average vector displacement was 4 mm (range, 2-7 mm). The average superior/inferior shift was 2 mm (range, 0-5 mm), the average lateral shift was 2 mm (range, 1-4 mm), and the average anterior/posterior shift was 3 mm (range, 1 5 mm). Conclusions: This study shows that the use of IGRT can be successfully used in an accelerated partial breast intensity-modulated radiotherapy protocol. The authors believe that this technique has increased daily treatment accuracy and permitted reduction in the margin added to the clinical target volume to form the planning target volume.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Daily Image Guidance With Cone-Beam Computed Tomography for Head-and-Neck Cancer Intensity-Modulated Radiotherapy: A Prospective Study

Purpose: To report on a prospective clinical trial of the use of daily kilovoltage cone-beam computed tomography (CBCT) to evaluate the interfraction and residual error motion of patients undergoing intensity-modulated radiotherapy for head-and-neck cancer. Methods and Materials: Patients were treated with intensity-modulated radiotherapy with an Elekta linear accelerator using a mounted CBCT scanner. CBCT was performed before every treatment, and translational (but not rotational) corrections were performed. At least once per week, a CBCT scan was obtained after intensity-modulated radiotherapy. Variations were measured in the medial-lateral, superoinferior, and anteroposterior dimensions, as well as in the rotation around these axes. Results: A total of 28 consecutive patients (1,013 CBCT scans) were studied. The average interfraction shift was 1.4 +- 1.4, 1.7 +- 1.9, and 1.8 +- 2.1 mm in the medial-lateral, superoinferior, and anteroposterior dimensions, respectively. The corresponding average residual error shifts were 0.7 +- 0.8, 0.9 +- 0.9, and 0.9 +- 0.9 mm. These data indicate that in the absence of daily CBCT image-guided radiotherapy, a clinical target volume to planning target volume margin of 3.9, 4.1, and 4.9 mm is needed in the medial-lateral, superoinferior, and anteroposterior dimensions, respectively. With daily CBCT, corresponding margins of 1.6, 2.5, and 1.9 mm should be acceptable. Subgroup analyses showed that larynx cancers and/or intratreatment weight loss indicate a need for slightly larger clinical target volume to planning target volume margins. Conclusion: The results of our study have shown that image-guided radiotherapy using CBCT for head-and-neck cancer is effective. These data suggest it allows a reduction in the clinical target volume to planning target volume margins by about 50%, which could facilitate future studies of dose escalation and/or improved toxicity reduction. Caution is particularly warranted for cases in which the targets are mobile (e.g., the tongue).

62 RADIOLOGY AND NUCLEAR MEDICINE↗