Search NASA⌕ Search

SEARCH · Search NASA

Results for “module efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

Towards the next generation 23% efficient n-type cells with low cost manufacturing

Suniva, Inc., in collaboration with the University Center for Excellence in Photovoltaics (UCEP) at the Georgia Institute of Technology (GIT) proposed this comprehensive three year program to enable the development of an advanced high performance product that will help the US regain its competitive edge in PV. This project was designed to overcome cost and efficiency barriers through advances in PV science, technology innovation, low-cost manufacturing and full production of ~22.5% efficient n-type Si cells in Norcross, GA. At the heart of the project is the desire to complement the technology being developed concurrently under the Solarmat and ARPAe initiatives to develop a differentiated product superior in both performance and cost effectiveness to the competing alternatives available on the market, and push towards achieving SunShot objectives while ensuring a sustainable business model based on US manufacturing. A significant reduction of the costs in modules produced today will need to combine reductions in wafer costs, cell processing costs as well as module fabrication costs while delivering a product that is not only more efficient under test conditions but also increases the energy yield in outdoor operations. This project will result in a differentiated high performance product and technology that is consistent with sustaining PV manufacturing in the US for a longer term and further highlights the need for continued support for developing the next generation concepts that can keep US manufacturing thriving to support the growing demand for PV in the US and consistent with the US government’s mandates for energy independence.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ACDT: Architected Composite Data Types Trading-in Unfettered Data Access for Improved Execution

With Exascale performance and its challenges in mind, one ubiquitous concern among architects is energy efficiency. Petascale systems projected to Exascale systems are unsustainable at current power consumption rates. One major contributor to system-wide power consumption is the number of memory operations leading to data movement and management techniques applied by the runtime system. To address this problem, we present the concept of the Architected Composite Data Types (ACDT) framework. The framework is made aware of data composites, assigning them a specific layout, transformations and operators. Data manipulation overhead is amortized over a larger number of elements and program performance and power efficiency can be significantly improved. We developed the fundamentals of an ACDT framework on a massively multithreaded adaptive runtime system geared towards Exascale clusters. Showcasing the capability of ACDT, we exercised the framework with two representative processing kernels - Matrix Vector Multiply and the Cholesky Decomposition – applied to sparse matrices. As transformation modules, we applied optimized compress/decompress engines and configured invariant operators for maximum energy/performance efficiency. Additionally, we explored two different approaches based on transformation opaqueness in relation to the application. Under the first approach, the application is agnostic to compression and decompression activity. Such approach entails minimal changes to the original application code, but leaves out potential applicationspecific optimizations. The second approach exposes the decompression process to the application, hereby exposing optimization opportunities that can only be exploited with application knowledge. The experimental results show that the two approaches have their strengths in HW and SW respectively, where the SW approach can yield performance and power improvements that are an order of magnitude better than ACDT-oblivious, hand-optimized implementations.We consider the ACDT runtime framework an important component of compute nodes that will lead towards power efficient Exascale clusters.

exascale↗

Grain size modulation on BaTiO{sub 3} nanoparticles synthesized at room temperature

A new method is developed to synthesize massive BaTiO{sub 3} nanoparticles directly at room temperature. With this method, the synthesis efficiency is improved and mass preparation can be realized. Also, the grain size of the as-prepared nanoparticles can be modulated from several nanometers to 40 nm through proper selection of the content of water and the alkanol chain length of the dispersant. It was found that smaller water content and a larger alkanol chain length of the dispersant will lead to a finer grain size. The mechanisms of the grain size modulation of BaTiO{sub 3} nanoparticles are also discussed. - graphical abstract: This paper offers a direct facile approach to BaTiO{sub 3} nanoparticles at room temperature with a large quantity. The grain size can be modulated purposefully. Highlights: > Room temperature synthesis of BaTiO{sub 3} nanoparticles with large scale is realized. > Grain size can be controlled purposefully. > Effect of content of water on crystallization of BaTiO{sub 3} is revealed. > Influence of alkanol chain length of the dispersant is found.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Sheet silicon cell/module technology

The cost involved in the performance of the standard operations for the manufacture of silicon wafers is insignificant in the case of space photovoltaics applications. It is, however, a decisive factor with respect to terrestrial applications of silicon photovoltaic devices. In 1975, a program was, therefore, begun to develop low cost silicon solar arrays for terrestrial applications. The goal was silicon-based photovoltaic (PV) modules ready for installation at a selling price of $0.50/watt (1975 dollars). Sheet and ribbon silicon growth held out the promise of reduced cost through continuous operation, high material throughput, high material utilization efficiency, and a product whose shape lent itself to the assembly of high packing density modules. Attention is given to ribbon growth technologies, sheet technology generic problems, and ribbon cell and module technology status. It is concluded that the potential for crystalline ribbon silicon appears to be better today than ever before.

Morrison, A. D.↗

Comparison of Real-Time Pressure Rail Selection Algorithms for the Hybrid Hydraulic Electric Architecture: Case Study on a Track Loader

Abstract The hybrid hydraulic electric architecture (HHEA) seeks to combine the high power/torque/force density of hydraulics with the efficiency of electric machines. A set of common pressure rails is used to provide a majority of the power and this power is modulated by small electric machines to provide precise control for the operator. The HHEA has been studied in previous work using off-line dynamic programming optimization to determine energy efficient pressure rail selections, but this approach requires drive cycle information apriori. A Lagrange multiplier method has also been investigated where a set of gains (Lagrange multipliers) are optimized off-line with the idea the these gains, once determined, could be used for real-time operation. In this work, three new real-time pressure rail selection algorithms that do not require future drive cycle information are investigated; greedy, torque minimizing, and thresholding. The greedy control is found to only use 1% more energy than the globally optimal dynamic programming solution; but a model of energy loss is required.

24 POWER TRANSMISSION AND DISTRIBUTION↗

TH-AB-BRB-00: Research Opportunities with Digital Linear Accelerators

Current state-of-the art digital C-arm medical linear accelerators are capable of delivering radiation treatments with high level of automation, which affords coordinated motions of gantry, couch, and multileaf collimator (MLC) with dose rate modulations. The new machine capacity has shown the potential to bring substantially improved radiation dosimetry and/or delivery efficiency to many challenging diseases. Combining an integrated beam orientation optimization algorithm with automated machine navigation, markedly improved dose conformity has been achieved using 4ρ therapy. Trajectory modulated radiation therapy (TMAT) can be used to deliver highly conformal dose to partial breast or to carve complex dose distribution for therapy involving extended volumes such as total marrow and total lymph node treatment. Dynamic electron arc radiotherapy (DEAR) not only overcomes the deficiencies of conventional electron therapy in dose conformity and homogeneity but also achieves so without patient-specific shields. The combination of MLC and couch tracking provides improved motion management of thoracic and abdominal tumors. A substantial body of work has been done in these technological advances for clinical translation. The proposed symposium will provide a timely review of these exciting opportunities. Learning Objectives: Recognize the potential of using digitally controlled linacs for clinically significant improvements in delivered dose distributions for various treatment sites. Identify existing approaches to treatment planning, optimization and delivery for treatment techniques utilizing the advanced functions of digital linacs and venues for further development and improvement. Understand methods for testing and validating delivery system performance. Identify tools available on current delivery systems for implementation and control for such treatments. Obtain the update in clinical applications, trials and regulatory approval. K. Sheng, NIH U19AI067769, NIH R43CA183390, NIH R01CA188300, Varian Medical Systems V. Yu, Varian Medical Systems, AAPM Summer Undergraduate Fellowship, NSF graduate fellowship S. Nill, Elekta AB. Cancer Research UK under Programme C33589/A19727, NIHR Biomedical Research Centre at The Royal Marsden and The Institute of Cancer Research.

60 APPLIED LIFE SCIENCES↗

TH-AB-BRB-01: Trajectory Modulated Arc Therapy: Application to Partial Breast Irradiation

Current state-of-the art digital C-arm medical linear accelerators are capable of delivering radiation treatments with high level of automation, which affords coordinated motions of gantry, couch, and multileaf collimator (MLC) with dose rate modulations. The new machine capacity has shown the potential to bring substantially improved radiation dosimetry and/or delivery efficiency to many challenging diseases. Combining an integrated beam orientation optimization algorithm with automated machine navigation, markedly improved dose conformity has been achieved using 4ρ therapy. Trajectory modulated radiation therapy (TMAT) can be used to deliver highly conformal dose to partial breast or to carve complex dose distribution for therapy involving extended volumes such as total marrow and total lymph node treatment. Dynamic electron arc radiotherapy (DEAR) not only overcomes the deficiencies of conventional electron therapy in dose conformity and homogeneity but also achieves so without patient-specific shields. The combination of MLC and couch tracking provides improved motion management of thoracic and abdominal tumors. A substantial body of work has been done in these technological advances for clinical translation. The proposed symposium will provide a timely review of these exciting opportunities. Learning Objectives: Recognize the potential of using digitally controlled linacs for clinically significant improvements in delivered dose distributions for various treatment sites. Identify existing approaches to treatment planning, optimization and delivery for treatment techniques utilizing the advanced functions of digital linacs and venues for further development and improvement. Understand methods for testing and validating delivery system performance. Identify tools available on current delivery systems for implementation and control for such treatments. Obtain the update in clinical applications, trials and regulatory approval. K. Sheng, NIH U19AI067769, NIH R43CA183390, NIH R01CA188300, Varian Medical Systems V. Yu, Varian Medical Systems, AAPM Summer Undergraduate Fellowship, NSF graduate fellowship S. Nill, Elekta AB. Cancer Research UK under Programme C33589/A19727, NIHR Biomedical Research Centre at The Royal Marsden and The Institute of Cancer Research.

60 APPLIED LIFE SCIENCES↗

TH-AB-BRB-02: ET-Reloaded

Current state-of-the art digital C-arm medical linear accelerators are capable of delivering radiation treatments with high level of automation, which affords coordinated motions of gantry, couch, and multileaf collimator (MLC) with dose rate modulations. The new machine capacity has shown the potential to bring substantially improved radiation dosimetry and/or delivery efficiency to many challenging diseases. Combining an integrated beam orientation optimization algorithm with automated machine navigation, markedly improved dose conformity has been achieved using 4ρ therapy. Trajectory modulated radiation therapy (TMAT) can be used to deliver highly conformal dose to partial breast or to carve complex dose distribution for therapy involving extended volumes such as total marrow and total lymph node treatment. Dynamic electron arc radiotherapy (DEAR) not only overcomes the deficiencies of conventional electron therapy in dose conformity and homogeneity but also achieves so without patient-specific shields. The combination of MLC and couch tracking provides improved motion management of thoracic and abdominal tumors. A substantial body of work has been done in these technological advances for clinical translation. The proposed symposium will provide a timely review of these exciting opportunities. Learning Objectives: Recognize the potential of using digitally controlled linacs for clinically significant improvements in delivered dose distributions for various treatment sites. Identify existing approaches to treatment planning, optimization and delivery for treatment techniques utilizing the advanced functions of digital linacs and venues for further development and improvement. Understand methods for testing and validating delivery system performance. Identify tools available on current delivery systems for implementation and control for such treatments. Obtain the update in clinical applications, trials and regulatory approval. K. Sheng, NIH U19AI067769, NIH R43CA183390, NIH R01CA188300, Varian Medical Systems V. Yu, Varian Medical Systems, AAPM Summer Undergraduate Fellowship, NSF graduate fellowship S. Nill, Elekta AB. Cancer Research UK under Programme C33589/A19727, NIHR Biomedical Research Centre at The Royal Marsden and The Institute of Cancer Research.

60 APPLIED LIFE SCIENCES↗

TH-AB-BRB-03: 4n Radiotherapy

Current state-of-the art digital C-arm medical linear accelerators are capable of delivering radiation treatments with high level of automation, which affords coordinated motions of gantry, couch, and multileaf collimator (MLC) with dose rate modulations. The new machine capacity has shown the potential to bring substantially improved radiation dosimetry and/or delivery efficiency to many challenging diseases. Combining an integrated beam orientation optimization algorithm with automated machine navigation, markedly improved dose conformity has been achieved using 4ρ therapy. Trajectory modulated radiation therapy (TMAT) can be used to deliver highly conformal dose to partial breast or to carve complex dose distribution for therapy involving extended volumes such as total marrow and total lymph node treatment. Dynamic electron arc radiotherapy (DEAR) not only overcomes the deficiencies of conventional electron therapy in dose conformity and homogeneity but also achieves so without patient-specific shields. The combination of MLC and couch tracking provides improved motion management of thoracic and abdominal tumors. A substantial body of work has been done in these technological advances for clinical translation. The proposed symposium will provide a timely review of these exciting opportunities. Learning Objectives: Recognize the potential of using digitally controlled linacs for clinically significant improvements in delivered dose distributions for various treatment sites. Identify existing approaches to treatment planning, optimization and delivery for treatment techniques utilizing the advanced functions of digital linacs and venues for further development and improvement. Understand methods for testing and validating delivery system performance. Identify tools available on current delivery systems for implementation and control for such treatments. Obtain the update in clinical applications, trials and regulatory approval. K. Sheng, NIH U19AI067769, NIH R43CA183390, NIH R01CA188300, Varian Medical Systems V. Yu, Varian Medical Systems, AAPM Summer Undergraduate Fellowship, NSF graduate fellowship S. Nill, Elekta AB. Cancer Research UK under Programme C33589/A19727, NIHR Biomedical Research Centre at The Royal Marsden and The Institute of Cancer Research.

60 APPLIED LIFE SCIENCES↗

TH-AB-BRB-04: Quality Assurance for Advanced Digital Linac Implementations

Current state-of-the art digital C-arm medical linear accelerators are capable of delivering radiation treatments with high level of automation, which affords coordinated motions of gantry, couch, and multileaf collimator (MLC) with dose rate modulations. The new machine capacity has shown the potential to bring substantially improved radiation dosimetry and/or delivery efficiency to many challenging diseases. Combining an integrated beam orientation optimization algorithm with automated machine navigation, markedly improved dose conformity has been achieved using 4ρ therapy. Trajectory modulated radiation therapy (TMAT) can be used to deliver highly conformal dose to partial breast or to carve complex dose distribution for therapy involving extended volumes such as total marrow and total lymph node treatment. Dynamic electron arc radiotherapy (DEAR) not only overcomes the deficiencies of conventional electron therapy in dose conformity and homogeneity but also achieves so without patient-specific shields. The combination of MLC and couch tracking provides improved motion management of thoracic and abdominal tumors. A substantial body of work has been done in these technological advances for clinical translation. The proposed symposium will provide a timely review of these exciting opportunities. Learning Objectives: Recognize the potential of using digitally controlled linacs for clinically significant improvements in delivered dose distributions for various treatment sites. Identify existing approaches to treatment planning, optimization and delivery for treatment techniques utilizing the advanced functions of digital linacs and venues for further development and improvement. Understand methods for testing and validating delivery system performance. Identify tools available on current delivery systems for implementation and control for such treatments. Obtain the update in clinical applications, trials and regulatory approval. K. Sheng, NIH U19AI067769, NIH R43CA183390, NIH R01CA188300, Varian Medical Systems V. Yu, Varian Medical Systems, AAPM Summer Undergraduate Fellowship, NSF graduate fellowship S. Nill, Elekta AB. Cancer Research UK under Programme C33589/A19727, NIHR Biomedical Research Centre at The Royal Marsden and The Institute of Cancer Research.

60 APPLIED LIFE SCIENCES↗

TH-AB-BRB-05: Using a Research Real-Time Control Interface to Go Beyond Dynamic MLC Tracking

Current state-of-the art digital C-arm medical linear accelerators are capable of delivering radiation treatments with high level of automation, which affords coordinated motions of gantry, couch, and multileaf collimator (MLC) with dose rate modulations. The new machine capacity has shown the potential to bring substantially improved radiation dosimetry and/or delivery efficiency to many challenging diseases. Combining an integrated beam orientation optimization algorithm with automated machine navigation, markedly improved dose conformity has been achieved using 4ρ therapy. Trajectory modulated radiation therapy (TMAT) can be used to deliver highly conformal dose to partial breast or to carve complex dose distribution for therapy involving extended volumes such as total marrow and total lymph node treatment. Dynamic electron arc radiotherapy (DEAR) not only overcomes the deficiencies of conventional electron therapy in dose conformity and homogeneity but also achieves so without patient-specific shields. The combination of MLC and couch tracking provides improved motion management of thoracic and abdominal tumors. A substantial body of work has been done in these technological advances for clinical translation. The proposed symposium will provide a timely review of these exciting opportunities. Learning Objectives: Recognize the potential of using digitally controlled linacs for clinically significant improvements in delivered dose distributions for various treatment sites. Identify existing approaches to treatment planning, optimization and delivery for treatment techniques utilizing the advanced functions of digital linacs and venues for further development and improvement. Understand methods for testing and validating delivery system performance. Identify tools available on current delivery systems for implementation and control for such treatments. Obtain the update in clinical applications, trials and regulatory approval. K. Sheng, NIH U19AI067769, NIH R43CA183390, NIH R01CA188300, Varian Medical Systems V. Yu, Varian Medical Systems, AAPM Summer Undergraduate Fellowship, NSF graduate fellowship S. Nill, Elekta AB. Cancer Research UK under Programme C33589/A19727, NIHR Biomedical Research Centre at The Royal Marsden and The Institute of Cancer Research.

60 APPLIED LIFE SCIENCES↗

Robust optimization for intensity-modulated proton therapy with soft spot sensitivity regularization

In this work, we developed a novel computationally efficient robust optimization method for IMPT. The robustness is calculated as the spot sensitivity to both range and shift perturbations. The dose fidelity term is then regularized by the sensitivity term for the flexibility and trade-off between the dosimetry and the robustness. In the stress test, SenR is more resilient to unexpected uncertainties. These advantages in combination with its fast computation time make it a viable candidate for clinical IMPT planning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Reliability and Power Degradation Rates of PERC Modules Using Differentiated Packaging Strategies and Characterization Tools

The reliability, durability and lifetime performance of passivated emitter, rear cell (PERC) modules used in real-world PV power plants is a critical challenge underlying the rapid adoption and bankability of these PERC cells, whose high efficiency help reduce the levelized cost of electricity (LCOE). We propose a degradation-science study of PERC module degradation pathways, benchmarking them relative to known degradation mechanisms and pathways of the incumbent aluminum back surface field (Al-BSF) modules exposed to real-world and accelerated exposure conditions.

14 SOLAR ENERGY↗

Using Beam Echo Effect for Generation of Short-Wavelength Radiation

We propose to use an echo effect previously observed in hadron accelerators for up-frequency conversion of density modulation in an electron beam. We show that, for generation of high harmonics, this method is much more efficient in comparison with the currently used approach. A one dimensional model of the effect is developed which allows to optimize the amplitude of the modulation for a given harmonic number.

43 PARTICLE ACCELERATORS↗

A novel Ka-band coaxial transit-time oscillator with a four-gap buncher

A novel Ka-band coaxial transit-time oscillator (TTO) with a four-gap buncher is proposed and investigated. Simulation results show that an output power of 1.27 GW and a frequency of 26.18 GHz can be achieved with a diode voltage of 447 kV and a beam current of 7.4 kA. The corresponding power efficiency is 38.5%, and the guiding magnetic field is 0.6 T. Studies and analysis indicate that a buncher with four gaps can modulate the electron beam better than the three-gap buncher in such a Ka-band TTO. Moreover, power efficiency increases with the coupling coefficient between the buncher and the extractor. Further simulation demonstrates that power efficiency can reach higher than 30% with a guiding magnetic field of above 0.5 T. Besides, the power efficiency exceeds 30% in a relatively large range of diode voltage from 375 kV to 495 kV.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Observation of proximities between spin-1/2 and quadrupolar nuclei: Which heteronuclear dipolar recoupling method is preferable?

We have recently shown that the dipolar-mediated heteronuclear multiple-quantum coherence (D-HMQC) method allows observing through-space proximities between spin-1/2 ({sup 1}H, {sup 13}C, {sup 31}P Horizontal-Ellipsis ) and quadrupolar ({sup 23}Na, {sup 27}Al Horizontal-Ellipsis ) nuclei. However, the D-HMQC effectiveness depends on the choice of the heteronuclear dipolar recoupling sequence. Here, we compare the efficiency and the robustness of four rotor-synchronized sequences: the symmetry-based ones, R4{sub 1}{sup 2}R4{sub 1}{sup -2} and its super-cycled version, SR4{sub 1}{sup 2}, and two schemes based on simultaneous amplitude and frequency modulations, denoted SFAM-1 and SFAM-2. For the SFAM methods, we point out efficient recoupling conditions that facilitate their experimental optimization and we introduce analytical expressions for the buildup of D-HMQC signal in the case of an isolated spin pair. We show that the main differences between these four sequences lie in the number of adjustable parameters and in their robustness with respect to chemical shift and homonuclear dipolar interactions. The relative performances of these four recoupling sequences are analyzed using average Hamiltonian theory, numerical simulations, and {sup 27}Al-{l_brace}{sup 31}P{r_brace} D-HMQC experiments on crystalline aluminophosphate.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Results for the Subjective Habitability Acceptability Questionnaire From HERA C5 and C6

BACKGROUND The impact of habitability on psychological and performance outcomes is recognized as an important factor in habitat and vehicle design—especially as missions increase in length. Formal evaluation of habitability’s impact is possible using the Spaceflight Habitability Acceptability Questionnaire (SHAQ), which was psychometrically validated by Roma et al. in 2022 [1]. The SHAQ survey systematically quantifies the relationships between habitat areas (e.g., bedroom, kitchen, hygiene area, office, etc.) and behavioral health and performance (BHP) outcomes (i.e., individual and team performance, mood, stress, sleep, social interaction), and considers the moderating effects of key habitability aspects (i.e., privacy, control, convenience, efficiency, comfort, social density) on that relationship. METHOD Respondents were HERA participants from Campaign 5 and 6 (n = 32). Data from three environments were used in our SHAQ analyses: SHAQ in HERA (in-mission), SHAQ at Home (pre-mission), and SHAQ in Hotel (pre- and post-mission for C6, just pre-mission for C5). For each habitat area, respondents are asked how that area layout impacts six BHP outcomes on a 201-point visual analog scale with the anchors: impairs, has no effect, and facilitates. They also had the option to respond “Not Applicable”. Follow up questions asked why six key habitability aspects (e.g., privacy) influenced the way the habitat area affected a given outcome. Participants indicated whether a habitat area’s habitability aspects were inadequate (low score) to adequate (midpoint) to ideal (high score), using a 201-point visual analog scale as well but were binned to a 7-point scale for analyses. RESULTS AND CONCLUSION When comparing across environments, ratings of BHP outcomes were worse in HERA compared to home and pre-mission hotel, but rebounded for the post-mission hotel such that post-mission hotel rating were often higher than all previous ratings. Within HERA, ratings of how a habitat area impacted an outcome skewed towards facilitation with communal areas (i.e., galley and office) rated most facilitating. The follow up questions about why six key aspects related to habitability moderated outcomes indicated that most habitat areas were rated as having “adequate” habitability characteristics. Privacy was the only moderator with average scores below adequate for all habitat areas. The office had the most moderators scoring above adequate for all habitat areas. Ratings indicated small to moderate effects of layouts on BHP outcomes: with facilitating layouts averaging between 4 and 5, and impairing layouts averaging between 2 and 4. The sleeping module layout facilitated sleep, with ratings indicating adequate comfort but inadequate privacy. The galley layout facilitated social interaction and mood, with ratings indicating adequate efficiency and convenience. The office layout facilitated social interaction, team and individual performance, with ratings similarly indicating adequate efficiency and convenience. The hygiene module worsened individual performance, mood and stress, with ratings indicating less than adequate privacy and social density. Our findings suggest there is value in having dedicated team and individual spaces. REFERENCES [1] Roma, P. G., Landon, L.B., Spencer, C. A., Whitmire, A. M., & Williams, T. J. (2022). SHAQ: Development and Validation. Human Factors: Special Issue on Spaceflight, 65(6), 1074-1104. ACKNOWLEDGEMENTS This project was funded by the NASA Human Research Program directed task Human Factors and Behavioral Performance in HERA (PI = S. Bell) to the BHP Lab. KBR Inc. and JES Tech authors were supported by KBR’s Human Health and Performance Contract NNJ15HK11B with NASA.

behavioral health↗