Search NASA⌕ Search

SEARCH · Search NASA

Results for “module performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

SU-E-J-80: Interplay Effect Between VMAT Intensity Modulation and Tumor Motion in Hypofractioned Lung Treatment, Investigated with 3D Pressage Dosimeter

Purpose: To demonstrate an embedded tissue equivalent presage dosimeter for measuring 3D doses in moving tumors and to study the interplay effect between the tumor motion and intensity modulation in hypofractioned Volumetric Modulated Arc Therapy(VMAT) lung treatment. Methods: Motion experiments were performed using cylindrical Presage dosimeters (5cm diameter by 7cm length) mounted inside the lung insert of a CIRS thorax phantom. Two different VMAT treatment plans were created and delivered in three different scenarios with the same prescribed dose of 18 Gy. Plan1, containing a 2 centimeter spherical CTV with an additional 2mm setup margin, was delivered on a stationary phantom. Plan2 used the same CTV except expanded by 1 cm in the Sup-Inf direction to generate ITV and PTV respectively. The dosimeters were irradiated in static and variable motion scenarios on a Truebeam system. After irradiation, high resolution 3D dosimetry was performed using the Duke Large Field-of-view Optical-CT Scanner, and compared to the calculated dose from Eclipse. Results: In the control case (no motion), good agreement was observed between the planned and delivered dose distributions as indicated by 100% 3D Gamma (3% of maximum planned dose and 3mm DTA) passing rates in the CTV. In motion cases gamma passing rates was 99% in CTV. DVH comparisons also showed good agreement between the planned and delivered dose in CTV for both control and motion cases. However, differences of 15% and 5% in dose to PTV were observed in the motion and control cases respectively. Conclusion: With very high dose nature of a hypofraction treatment, significant effect was observed only motion is introduced to the target. This can be resulted from the motion of the moving target and the modulation of the MLC. 3D optical dosimetry can be of great advantage in hypofraction treatment dose validation studies.

60 APPLIED LIFE SCIENCES↗

The Holy Grail of Resource Assessment: Low Cost Ground-Based Measurements with Good Accuracy

Using performance data from some of the millions of installed photovoltaic (PV) modules with micro-inverters may afford the opportunity to provide ground-based solar resource data critical for developing PV projects. The method used back-solves for the direct normal irradiance (DNI) and the diffuse horizontal irradiance (DHI) from the micro-inverter ac production data. When the derived values of DNI and DHI were then used to model the performance of other PV systems, the annual mean bias deviations were within +/-4%, and only 1% greater than when the PV performance was modeled using high quality irradiance measurements. An uncertainty analysis shows the method better suited for modeling PV performance than using satellite-based global horizontal irradiance.

14 SOLAR ENERGY↗

The Holy Grail of Resource Assessment: Low Cost Ground-Based Measurements with Good Accuracy

Using performance data from some of the millions of installed photovoltaic (PV) modules with micro-inverters may afford the opportunity to provide ground-based solar resource data critical for developing PV projects. The method used back-solves for the direct normal irradiance (DNI) and the diffuse horizontal irradiance (DHI) from the micro-inverter ac production data. When the derived values of DNI and DHI were then used to model the performance of other PV systems, the annual mean bias deviations were within +/- 4%, and only 1% greater than when the PV performance was modeled using high quality irradiance measurements. An uncertainty analysis shows the method better suited for modeling PV performance than using satellite-based global horizontal irradiance.

14 SOLAR ENERGY↗

The Holy Grail of Resource Assessment: Low Cost Ground-Based Measurements with Good Accuracy: Preprint

Using performance data from some of the millions of installed photovoltaic (PV) modules with micro-inverters may afford the opportunity to provide ground-based solar resource data critical for developing PV projects. The method used back-solves for the direct normal irradiance (DNI) and the diffuse horizontal irradiance (DHI) from the micro-inverter ac production data. When the derived values of DNI and DHI were then used to model the performance of other PV systems, the annual mean bias deviations were within plus or minus 4 percent, and only 1 percent greater than when the PV performance was modeled using high quality irradiance measurements. An uncertainty analysis shows the method better suited for modeling PV performance than using satellite-based global horizontal irradiance.

14 SOLAR ENERGY↗

Range and modulation dependencies for proton beam dose per monitor unit calculations

Calculations of dose per monitor unit (D/MU) are required in addition to measurements to increase patient safety in the clinical practice of proton radiotherapy. As in conventional photon and electron therapy, the D/MU depends on several factors. This study focused on obtaining range and modulation dependence factors used in D/MU calculations for the double scattered proton beam line at the Midwest Proton Radiotherapy Institute. Three dependencies on range and one dependency on modulation were found. A carefully selected set of measurements was performed to discern these individual dependencies. Dependencies on range were due to: (1) the stopping power of the protons passing through the monitor chamber; (2) the reduction of proton fluence due to nuclear interactions within the patient; and (3) the variation of proton fluence passing through the monitor chamber due to different source-to-axis distances (SADs) for different beam ranges. Different SADs are produced by reconfigurations of beamline elements to provide different field sizes and ranges. The SAD effect on the D/MU varies smoothly as the beam range is varied, except at the beam range for which the first scatterers are exchanged and relocated to accommodate low and high beam ranges. A geometry factor was devised to model the SAD variation effect on the D/MU. The measured D/MU variation as a function of range can be predicted within 1% using the three modeled dependencies on range. Investigation of modulated beams showed that an analytical formula can predict the D/MU dependency as a function of modulation to within 1.5%. Special attention must be applied when measuring the D/MU dependence on modulation to avoid interplay between range and SAD effects.

61 RADIATION PROTECTION AND DOSIMETRY↗

FiberFlex: Real-time FPGA-based Intelligent and Distributed Fiber Sensor System for Pedestrian Recognition

In recent years, security monitoring of public places and critical infrastructure has heavily relied on the widespread use of cameras, raising concerns about personal privacy violations. To balance the need for effective security monitoring with the protection of personal privacy, we explore the potential of optical fiber sensors for this application. This article proposes FiberFlex, an intelligent and distributed fiber sensor system. Ultizing Field Programmable Gate Arrays (FPGA) high-level synthesis (HLS) acceleration, FiberFlex offers real-time pedestrian detection by co-designing the entire pipeline of optical signal acquisition, processing, and recognition networks based on the principles of optical fiber sensing. As a promising alternative to traditional camera-based monitoring systems, FiberFlex achieves pedestrian detection by analyzing the vibration patterns caused by pedestrian footsteps, enabling security monitoring while preserving individual privacy. FiberFlex comprises three modules: First , fiber-optic sensing system: A fiber-optic distributed acoustic sensing (DAS) system is built and used to measure the ground vibration waves generated by people walking. Second , algorithms: We first collect the training data by measuring the ground vibration waves, label the data, and use the data to train the neural network models to perform pedestrian recognition. Third , hardware accelerators: We use HLS tools to design hardware modules on FPGA for data collection and pre-processing and integrate them with the downstream neural network accelerators to perform in-line real-time pedestrian detection. The final detection results are sent back from FPGA to the host CPU. We implement our system FiberFlex with the in-house built DAS system and AMD/Xilinx Kintex7 FPGA KC705 board and verify the whole system using the real-world collected data. We conduct recognition tests on five test subjects of varying ages, heights, and weights in a fixed sensing area. Each subject experienced 20 real-time recognition tests using their daily walking habits, and the subjects were given adequate rest between tests. After 100 tests on five test subjects, the overall real-time recognition accuracy exceeded \(88.0\%\) . The whole system uses 55 W of power, 33 W in the optical DAS system and 22 W in the FPGA. Relying on its end-to-end interdisciplinary design, FiberFlex seamlessly combines fiber-optic sensors with FPGA accelerators to enable low-power real-time security monitoring without compromising privacy, making it a valuable addition to the existing security monitoring network. According to FiberFlex, more valuable research can be conducted in the future, such as fall monitoring for the elderly, migration of identification networks between different application scenarios, and improvement of anti-interference performance in more complex environments. In future perception networks, where the “eyes” are not feasible, let’s use fiber optic touch instead.

Distributed↗

The Mu2e crystal calorimeter

The Mu2e experiment at Fermilab will search for the charged-lepton flavour violating conversion of negative muons into electrons in the coulomb field of an Al nucleus, planning to reach a single event sensitivity of about $3\cdot10^{−17}$, four orders of magnitude beyond the current best limit.The conversion electron has a clear monoenergetic signature at 104.967 MeV, slightly below the muon rest mass, and will be identified by a complementary measurement carried out by a high-resolution tracker and an electromagnetic calorimeter (EMC). The calorimeter is composed of 1348 pure CsI crystals, each read by two custom UV-extended SiPMs, that are arranged in two annular disks. The EMC should achieve better than 10% energy resolution and 500 ps timing resolution for 100 MeV electrons and maintain extremely high levels of reliability and stability and in a harsh operating environment with high vacuum, 1 T B-field and radiation exposures up to 100 krad and $10^{12} \rm{n}_\rm{1MeVeq}/\rm{cm}^{2}$.The calorimeter technological choice, along with the design of the custom front-end electronics, cooling and mechanical systems were validated through an electron beam test on a large-scale 51-crystals prototype (Module-0) and extensive test campaigns that characterised and verified the performance of crystals, photodetectors, analogue and digital electronics. This included hardware stress tests and irradiation campaigns with neutrons, protons, and photons.The production and QC phases of all calorimeter components is completed apart for the digital electronics that has been revised for improving its resilience to SEU and SEL. A series of vertical slice tests with the final electronics is being carried out on the Module-0 at LNF along with the implementation and validation of the calibration procedures. The first disk has been assembled in 2022 while the second disk is under assembly at the moment of writing. Status of construction will be summarised, along with plans for commissioning and first calibration of the fully assembled disks.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Rapid methods for radionuclide contaminant transport in nuclear fuel cycle simulation

Here, nuclear fuel cycle and nuclear waste disposal decisions are technologically coupled. However, current nuclear fuel cycle simulators lack dynamic repository performance analysis due to the computational burden of high-fidelity hydrolgic contaminant transport models. The Cyder disposal environment and repository module was developed to fill this gap. It implements medium-fidelity hydrologic radionuclide transport models to support assessment appropriate for fuel cycle simulation in the Cyclus fuel cycle simulator. Rapid modeling of hundreds of discrete waste packages in a geologic environment is enabled within this module by a suite of four closed form models for advective, dispersive, coupled, and idealized con- taminant transport: a Degradation Rate model, a Mixed Cell model, a Lumped Parameter model, and a 1-D Permeable Porous Medium model. A summary of the Cyder module, its timestepping algorithm, and the mathematical models implemented within it are presented. Additionally, parametric demonstrations simulations performed with Cyder are presented and shown to demonstrate functional agreement with parametric simulations conducted in a standalone hydrologic transport model, the Clay Generic Disposal System Model developed by the Used Fuel Disposition Campaign Department of Energy Office of Nuclear Energy.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Electric field modulation of Schottky barrier height in graphene/MoSe{sub 2} van der Waals heterointerface

We demonstrate a vertical field-effect transistor based on a graphene/MoSe{sub 2} van der Waals (vdW) heterostructure. The vdW interface between the graphene and MoSe{sub 2} exhibits a Schottky barrier with an ideality factor of around 1.3, suggesting a high-quality interface. Owing to the low density of states in graphene, the position of the Fermi level in the graphene can be strongly modulated by an external electric field. Therefore, the Schottky barrier height at the graphene/MoSe{sub 2} vdW interface is also modulated. We demonstrate a large current ON-OFF ratio of 10{sup 5}. These results point to the potential high performance of the graphene/MoSe{sub 2} vdW heterostructure for electronics applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Multi-Split Variable Refrigerant Flow (VRF) System Building Energy Simulations Using Performance Maps

Multi-split variable refrigerant flow (VRF) systems are highly energy-efficient HVAC (heating, ventilation and air conditioning) technologies that connect a single outdoor unit to multiple independent indoor terminal units using a common refrigerant circuit and a variable-speed compressor. Building energy simulations that incorporate VRF systems help model their unique operational characteristics and predict energy consumption in specific building designs. Traditionally, EnergyPlus models these systems by employing multiple sets of performance curves to characterize both individual terminal units and the outdoor unit. However, producing these curves is labor intensive and error prone, and they often do not capture all the key input and output variables. This paper introduces a novel approach that uses multi-dimensional performance maps to model VRF systems in building environments for space cooling. In this approach, performance maps are developed at the component level—separately for the outdoor unit and for each indoor terminal. The new modeling method is validated within EnergyPlus via a Python plug-in that contains a simple solver loop to coordinate the component-level, indoor, and outdoor unit maps. Furthermore, because performance maps can span more variables than traditional performance curves, they offer the opportunity to implement advanced controls, such as enhanced dehumidification and compressor modulation. A VRF air conditioner’s hardware system was modeled using the DOE/ORNL Heat Pump Design Model, which was automated to produce extensive performance maps for both the indoor and outdoor units.

Shen, Bo [ORNL] (ORCID:0000000336600393)↗

Modeling and design of tin doped group IV alloy based QWEAM

This work investigates vital characteristics of tin doped group IV based quantum well for its potential as an electroabsorption modulator (EAM). Absorption coefficient and refractive index variation in proposed EAM structure are evaluated and studied under variation of electric field. Performance parameters like extinction ratio, chirp factor, etc. are calculated for different electric fields and Sn content of GeSn quantum well. A significant negative chirp and high extinction ratio has been obtained at midinfrared range of wavelength. The result reveals that appropriate selection of external field and Sn content plays a decisive role in the performance of QWEAM. Moreover, there is a tradeoff between extinction ratio and insertion loss on increasing length of the modulator.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Neck Muscle Coactivation Response to Varied Levels of Mental Workload During Simulated Flight Tasks

Objective To evaluate neck muscle coactivation across different levels of mental workload during simulated flight tasks. Background Neck pain (NP) is highly prevalent among military aviators. Given the complex nature within the flight environment, mental workload may be a risk factor for NP. This may induce higher levels of neck muscle coactivity, which over time may accelerate fatigue, increase neck discomfort, and affect flight task performance. Method Three counterbalanced mental workload conditions represented by simulated flight tasks modulated by interstimulus frequency and complexity were investigated using the Modifiable Multitasking Environment (ModME). The primary measure was a neck coactivation index to describe the neuromuscular effort of the neck muscles as a system. Additional measures included perceived workload (NASA TLX), subjective discomfort, and task performance. Participants ( n = 60; 30M, 30F) performed three test conditions over 1 hr each while seated in a simulated seating environment. Results Neck coactivation indices (CoA) and subjective neck discomfort corresponded with increasing level of mental workload. Average CoAs for low, medium, and high workloads were: .0278(SD = .0232), .0286(SD = .0231), and .0295(SD = .0228), respectively. NASA TLX mental, temporal, effort, and overall scores also increased with the level of mental workload assigned. For ModME task performance, the overall performance score, monitoring accuracy, and resource management accuracy decreased while reaction times increased with the increasing level of mental workload. Communication accuracy was lowest with the low mental workload but had higher reaction times relative to increasing workload. Conclusion Mental workload affects neck muscle coactivation during combinations of simulated flight tasks within a simulated helicopter seating environment. Application The results of this study provide insights into the physical response to mental workload. With increasing multisensory modalities within the work environment, these insights may assist the consideration of physical effects from cognitive factors.

Behavioral Sciences↗

Artifacts in time-resolved Kelvin probe force microscopy

Kelvin probe force microscopy (KPFM) has been used for the characterization of metals, insulators, and semiconducting materials on the nanometer scale. Especially in semiconductors, the charge dynamics are of high interest. Recently, several techniques for time-resolved measurements with time resolution down to picoseconds have been developed, many times using a modulated excitation signal, e.g. light modulation or bias modulation that induces changes in the charge carrier distribution. For fast modulation frequencies, the KPFM controller measures an average surface potential, which contains information about the involved charge carrier dynamics. Here, we show that such measurements are prone to artifacts due to frequency mixing, by performing numerical dynamics simulations of the cantilever oscillation in KPFM subjected to a bias-modulated signal. For square bias pulses, the resulting time-dependent electrostatic forces are very complex and result in intricate mixing of frequencies that may, in some cases, have a component at the detection frequency, leading to falsified KPFM measurements. Additionally, we performed fast Fourier transform (FFT) analyses that match the results of the numerical dynamics simulations. Small differences are observed that can be attributed to transients and higher-order Fourier components, as a consequence of the intricate nature of the cantilever driving forces. These results are corroborated by experimental measurements on a model system. In the experimental case, additional artifacts are observed due to constructive or destructive interference of the bias modulation with the cantilever oscillation. Also, in the case of light modulation, we demonstrate artifacts due to unwanted illumination of the photodetector of the beam deflection detection system. Lastly, guidelines for avoiding such artifacts are given.

36 MATERIALS SCIENCE↗

Validation of a Monte Carlo model used for simulating tube current modulation in computed tomography over a wide range of phantom conditions/challenges

Purpose: Monte Carlo (MC) simulation methods have been widely used in patient dosimetry in computed tomography (CT), including estimating patient organ doses. However, most simulation methods have undergone a limited set of validations, often using homogeneous phantoms with simple geometries. As clinical scanning has become more complex and the use of tube current modulation (TCM) has become pervasive in the clinic, MC simulations should include these techniques in their methodologies and therefore should also be validated using a variety of phantoms with different shapes and material compositions to result in a variety of differently modulated tube current profiles. The purpose of this work is to perform the measurements and simulations to validate a Monte Carlo model under a variety of test conditions where fixed tube current (FTC) and TCM were used. Methods: A previously developed MC model for estimating dose from CT scans that models TCM, built using the platform of MCNPX, was used for CT dose quantification. In order to validate the suitability of this model to accurately simulate patient dose from FTC and TCM CT scan, measurements and simulations were compared over a wide range of conditions. Phantoms used for testing range from simple geometries with homogeneous composition (16 and 32 cm computed tomography dose index phantoms) to more complex phantoms including a rectangular homogeneous water equivalent phantom, an elliptical shaped phantom with three sections (where each section was a homogeneous, but different material), and a heterogeneous, complex geometry anthropomorphic phantom. Each phantom requires varying levels of x-, y- and z-modulation. Each phantom was scanned on a multidetector row CT (Sensation 64) scanner under the conditions of both FTC and TCM. Dose measurements were made at various surface and depth positions within each phantom. Simulations using each phantom were performed for FTC, detailed x–y–z TCM, and z-axis-only TCM to obtain dose estimates. This allowed direct comparisons between measured and simulated dose values under each condition of phantom, location, and scan to be made. Results: For FTC scans, the percent root mean square (RMS) difference between measurements and simulations was within 5% across all phantoms. For TCM scans, the percent RMS of the difference between measured and simulated values when using detailed TCM and z-axis-only TCM simulations was 4.5% and 13.2%, respectively. For the anthropomorphic phantom, the difference between TCM measurements and detailed TCM and z-axis-only TCM simulations was 1.2% and 8.9%, respectively. For FTC measurements and simulations, the percent RMS of the difference was 5.0%. Conclusions: This work demonstrated that the Monte Carlo model developed provided good agreement between measured and simulated values under both simple and complex geometries including an anthropomorphic phantom. This work also showed the increased dose differences for z-axis-only TCM simulations, where considerable modulation in the x–y plane was present due to the shape of the rectangular water phantom. Results from this investigation highlight details that need to be included in Monte Carlo simulations of TCM CT scans in order to yield accurate, clinically viable assessments of patient dosimetry.

07 ISOTOPE AND RADIATION SOURCES↗

Air-Stable CuInSe 2 Nanocrystal Transistors and Circuits via Post-Deposition Cation Exchange

Colloidal semiconductor nanocrystals (NCs) are a promising materials class for solution-processable, next-generation electronic devices. However, most high-performance devices and circuits have been achieved using NCs containing toxic elements, which may limit their further device development. In this work, we fabricate high mobility CuInSe 2 NC field-effect transistors (FETs) using a solution-based, post-deposition, sequential cation exchange process that starts with electronically coupled, thiocyanate (SCN)-capped CdSe NC thin films. First Cu + is substituted for Cd 2+ transforming CdSe NCs to Cu-rich Cu 2 Se NC films. Next, Cu 2 Se NC films are dipped into a Na 2 Se solution to Se-enrich the NCs, thus compensating the Cu-rich surface, promoting fusion of the Cu 2 Se NCs, and providing sites for subsequent In-dopants. The liquid-coordination-complex trioctylphosphine–indium chloride (TOP–InCl 3 ) is used as a source of In 3+ to partially exchange and n -dope CuInSe 2 NC films. We demonstrate Al 2 O 3 -encapsulated, air-stable CuInSe 2 NC FETs with linear (saturation) electron mobilities of 8.2 ± 1.8 cm 2 /(V s) (10.5 ± 2.4 cm2/(V s)) and with current modulation of 10 5 , comparable to that for high-performance Cd-, Pb-, and As-based NC FETs. The CuInSe 2 NC FETs are used as building blocks of integrated inverters to demonstrate their promise for low-cost, low-toxicity NC circuits.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Spatial atomic layer deposition on flexible substrates using a modular rotating cylinder reactor

Spatial atomic layer deposition (ALD) is a new version of ALD based on the separation of reactant gases in space instead of time. In this paper, the authors present results for spatial ALD on flexible substrates using a modular rotating cylinder reactor. The design for this reactor is based on two concentric cylinders. The outer cylinder remains fixed and contains a series of slits. These slits can accept a wide range of modules that attach from the outside. The modules can easily move between the various slit positions and perform precursor dosing, purging, or pumping. The inner cylinder rotates with the flexible substrate and passes underneath the various spatially separated slits in the outer cylinder. Trimethyl aluminum and ozone were used to grow Al{sub 2}O{sub 3} ALD films at 40 °C on metallized polyethylene terephthalate (PET) substrates to characterize this spatial ALD reactor. Spectroscopic ellipsometry measurements revealed a constant Al{sub 2}O{sub 3} ALD growth rate of 1.03 Å/cycle with rotation speeds from 40 to 100 RPM with the outer cylinder configured for one Al{sub 2}O{sub 3} ALD cycle per rotation. The Al{sub 2}O{sub 3} ALD growth rate then decreased at higher rotation rates for reactant residence times < 5 ms. The Al{sub 2}O{sub 3} ALD films were also uniform to within <1% across the central portion of metallized PET substrate. Fixed deposition time experiments revealed that Al{sub 2}O{sub 3} ALD films could be deposited at 2.08 Å/s at higher rotation speeds of 175 RPM. Even faster deposition rates are possible by adding more modules for additional Al{sub 2}O{sub 3} ALD cycles for every one rotation of the inner cylinder.

36 MATERIALS SCIENCE↗

Modular Platforms for Advanced Inspection, Locomotion, and Manipulation - 17150

Robots can provide remote access, manipulation, and inspection capabilities to augment human workers and improve safety in potentially dangerous decommissioning, radioactive waste management, and emergency response operations. However, such activities may require navigating challenging and unstructured environments, such as those with uneven terrain, obstacles, or loose debris. This remains a difficult task, even for modern robots. What's more, a robot's physical design can inhibit it from accessing hard-to-reach areas such as the tight spaces around, underneath, or inside piping and equipment. To address these challenges, we have developed a series of physically robust hardware modules that can be configured into a variety of robot morphologies, specialized to support different operational needs. Each hardware module consists of a number of onboard sensors and a high performance actuator with a series elastic element to sense and control interaction forces for improved locomotion and manipulation. Using this hardware, we have designed several robotic platforms that support the access, manipulation, and inspection requirements of decommissioning and radioactive waste management. To highlight current capabilities and potential opportunities for technological improvement, we present the outcomes from field demonstrations of our modular platforms at the Office of Environmental Management's Science of Safety Portsmouth Gaseous Diffusion Plant Robotics Challenge. Specifically, results include a serpentine robot climbing vertical structures such as pipes, posts, and supports to demonstrate advanced inspection. Additionally, we discuss field trials of a similar modular configuration that yields a highly dexterous manipulator arm and camera system capable of adding manipulation and inspection functionality to existing structures. Results are presented from inspection tasks in which the manipulator is installed on another mobile robotic platform. Finally, we show our hardware modules can be reconfigured into platforms capable of withstanding significant impacts and of alternative means of locomotion, as may be required to cross terrain too challenging for traditional wheeled robots. Results describe the performance of a hexapod robot that uses proprioceptive feedback to locomote in outdoor trials reminiscent of emergency response conditions. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

An implicit barotropic mode solver for MPAS-ocean using a modern Fortran solver interface

Here, we demonstrate use of a modern Fortran solver interface to manage solver algorithms for an implicit barotropic mode solver in the Model for Predictions Across Scales-Ocean (MPAS-O). ForTrilinos, a Fortran interface to Trilinos that contains a large collection of solver capabilities written in C++, has been implemented in MPAS-O to provide access to a suite of linear solver options. By virtue of the simplified wrapper and interface generator (SWIG) automation tool that generates modern Fortran interfaces to C++ code, we were able to implement the Fortran solver interface in MPAS-O using a familiar Fortran coding style while minimizing performance degradation. The ForTrilinos solver interface is written within MPAS-O’s time stepping modules as a subroutine in conjunction with MPAS-O code. Applied to an idealized ocean and a high-resolution realistic ocean test case, parallel performance of ForTrilinos solvers is examined. It is found that parallel scalability of the ForTrilinos solvers is highly dependent on the number of global synchronization points per solver iteration in each iterative solver algorithm. ForTrilinos solvers perform best compared to the Fortran hand-crafted (FHC) solver when the amount of work per processor is large enough. However, parallel scalability is better with the FHC solver and so when the work per core is modest FHC outperforms ForTrilinos. The intercomparison between the ForTrilinos and FHC solvers reveals that this performance hit in the ForTrilinos solver mostly comes from the global synchronization process, while suggesting that the matrix-vector multiplication process in the FHC solver needs to be optimized for better performance.

97 MATHEMATICS AND COMPUTING↗