Search NASA⌕ Search

SEARCH · Search NASA

Results for “multiple beam”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

Mapping nanocrystal orientations via scanning Laue diffraction microscopy for multi-peak Bragg coherent diffraction imaging

The recent commissioning of a movable monochromator at the 34-ID-C endstation of the Advanced Photon Source has vastly simplified the collection of Bragg coherent diffraction imaging (BCDI) data from multiple Bragg peaks of sub-micrometre scale samples. Laue patterns arising from the scattering of a polychromatic beam by arbitrarily oriented nanocrystals permit their crystal orientations to be computed, which are then used for locating and collecting several non-co-linear Bragg reflections. The volumetric six-component strain tensor is then constructed by combining the projected displacement fields that are imaged using each of the measured reflections via iterative phase retrieval algorithms. Complications arise when the sample is heterogeneous in composition and/or when multiple grains of a given lattice structure are simultaneously illuminated by the polychromatic beam. Here, a workflow is established for orienting and mapping nanocrystals on a substrate of a different material using scanning Laue diffraction microscopy. The capabilities of the developed algorithms and procedures with both synthetic and experimental data are demonstrated. The robustness is verified by comparing experimental texture maps obtained with Laue diffraction microscopy at the beamline with maps obtained from electron back-scattering diffraction measurements on the same patch of gold nanocrystals. Such tools provide reliable indexing for both isolated and densely distributed nanocrystals, which are challenging to image in three dimensions with other techniques.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Laser-driven electron beamlines generated by coupling laser-plasma sources with conventional transport systems

Laser-driven electron beamlines are receiving increasing interest from the particle accelerator community. In particular, the high initial energy, low emittance, and high beam current of the plasma based electron source potentially allow generating much more compact and bright particle accelerators than what conventional accelerator technology can achieve. Using laser-generated particles as injectors for generating beamlines could significantly reduce the size and cost of accelerator facilities. Unfortunately, several features of laser-based particle beams need still to be improved before considering them for particle beamlines and thus enable the use of plasma-driven accelerators for the multiple applications of traditional accelerators. Besides working on the plasma source itself, a promising approach to shape the laser-generated beams is coupling them with conventional accelerator elements in order to benefit from both a versatile electron source and a controllable beam. In this paper, we perform start-to-end simulations to generate laser-driven beamlines using conventional accelerator codes and methodologies. Starting with laser-generated electrons that can be obtained with established multi-hundred TW laser systems, we compare different options to capture and transport the beams. This is performed with the aim of providing beamlines suitable for potential applications, such as free electron lasers. In our approach, we have analyzed which parameters are critical at the source and from there evaluated different ways to overcome these issues using conventional accelerator elements and methods. We show that electron driven beamlines are potentially feasible, but exploiting their full potential requires extensive improvement of the source parameters or innovative technological devices for their transport and capture.

43 PARTICLE ACCELERATORS↗

Multiple error data analysis for RHIC low-energy operations

In FY10, RHIC operated with gold beams at three different energies below its regular injection energy, namely at {radical}s = 5 GeV; 7.7 GeV; and 11.5 GeV: While beam lifetimes of about 10 minutes were achieved at 11.5 GeV and 7.7 GeV; leading to stable collider operation, beam lifetimes during tests at {radical}s = 5 GeV were only of the order of several seconds. Though space charge effects are a major concern in low energy operations due to the 1/{gamma}{sup 2} scaling of the space charge force, these can effectively be ruled out as the main cause of this abysmal performance because of the tiny bunch intensities of approximately 10{sub 8} Au/bunch, compared to 10{sup 9} Au/bunch at the two higher energies. During these 5 GeV tests, large betatron tune spreads were observed, but the extremely short beam lifetime prevented chromaticity measurements. Instead, chromaticities were scanned over a range of 40 units, but to no effect. It was therefore suspected at that time that the large tune spread was caused by higherorder multipole errors in the RHIC magnets.

43 PARTICLE ACCELERATORS↗

Multiple aperture airborne infrared measurements of Comet Halley

Observations at 10 microns with a 3.5' diameter beam made from the NASA Lear Jet Observatory during April 7.6 to 11.6, 1986 UT are presented. Data show evidence for a dramatic outburst (factor of 3 in 10 micron flux) with a turn-on time of 1 day and turn-off time of 1 to 2 days. Total mass ejected in the outburst is estimated. When combined with 8 and 10 microns data taken by Campins et al the dependence of the dust density on distance from the nucleus can be evaluated. It is shown that the flux within an aperture of diameter D is directly proportional to D well beyond 60" (2 million m at the comet). At 64 million m diameter (210"), the measurements are only 30% below the level expected for a strict F varies as d dependence. This, combined with the time scales of the event, places constraints on processes of grain destruction. The energy of the outburst is derived and compared to solar heating.

Russell, R. W.↗

A High Energy 2-microns Laser for Multiple Lidar Applications

Solid-state 2-microns laser has been receiving considerable interest because of its eye-safe property and efficient diode pump operation, It has potential for multiple lidar applications to detect water vapor. carbon dioxide and winds. In this paper, we describe a 2-microns double pulsed Ho:Tm:YLF laser and end-pumped amplifier system. A comprehensive theoretical model has been developed to aid the design and optimization of the laser performance. In a single Q-switched pulse operation the residual energy stored in the Tm atoms will be wasted. However, in a double pulses operation mode, the residual energy stored in the Tm atoms will repopulate the Ho atoms that were depleted by the extraction of the first Q-switched pulse. Thus. the Tin sensitized Ho:YLF laser provides a unique advantage in applications that require double pulse operation, such as Differential Absorption Lidar (DIAL). A total output energy of 146 mJ per pulse pair under Q-switch operation is achieved with as high as 4.8% optical to optical efficiency. Compared to a single pulse laser, 70% higher laser efficiency is realized. To obtain high energy while maintaining the high beam quality, a master-oscillator-power-amplifier 2-microns system is designed. We developed an end-pumped Ho:Tm:YLF disk amplifier. This amplifier uses two diode arrays as pump source. A non-imaging lens duct is used to couple the radiation from the laser diode arrays to the laser disk. Preliminary result shows that the efficiency of this laser can be as high as 3%, a factor of three increases over side-pump configuration. This high energy, highly efficient and high beam quality laser is a promising candidate for use in an efficient, multiple lidar applications.

Yu, Jirong↗

Current profile redistribution driven by neutral beam injection in a reversed-field pinch

Neutral beam injection in reversed-field pinch (RFP) plasmas on the Madison Symmetric Torus [Dexter et al., Fusion Sci. Technol. 19, 131 (1991)] drives current redistribution with increased on-axis current density but negligible net current drive. Internal fluctuations correlated with tearing modes are observed on multiple diagnostics; the behavior of tearing mode correlated structures is consistent with flattening of the safety factor profile. The first application of a parametrized model for island flattening to temperature fluctuations in an RFP allows inferrence of rational surface locations for multiple tearing modes. The m = 1, n = 6 mode is observed to shift inward by 1.1 ± 0.6 cm with neutral beam injection. Tearing mode rational surface measurements provide a strong constraint for equilibrium reconstruction, with an estimated reduction of q{sub 0} by 5% and an increase in on-axis current density of 8% ± 5%. The inferred on-axis current drive is consistent with estimates of fast ion density using TRANSP [Goldston et al., J. Comput. Phys. 43, 61 (1981)].

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

TU-F-CAMPUS-J-01: Dosimetric Effects of HU Changes During the Course of Proton Therapy for Lung Cancer

Purpose: To characterize the changes in Hounsfield unit (HU) in lung radiotherapy with proton beams during the course of treatment and to study the effect on the proton plan dose distribution. Methods: Twenty consecutive patients with non-small cell lung cancer treated with proton radiotherapy who underwent multiple CT scans including the planning CT and weekly verification CTs were studied. HU histograms were computed for irradiated lung volumes in beam paths for all scans using the same treatment plan. Histograms for un-irradiated lung volume were used as control to characterize inter-scan variations. HU statistics were calculated for both irradiated and un-irradiated lung volumes for each patient scan. Further, multiple CT scans based on the same planning CT were generated by replacing the HU of the lung based on the verification CT scans HU values. Using the same beam arrangement, we created plans for each of the altered CT scans to study the dosimetric effect using the dose volume histogram. Results: Lung HU decreased for irradiated lung volume during the course of radiotherapy. The magnitude of this change increased with total irradiation dose. On average, HU changed by −53.8 in the irradiated volume. This change resulted in less than 0.5mm of beam overshoot in tissue for every 1cm beam traversed in the irradiated lung. The dose modification is about +3% for the lung, and less than +1% for the primary tumor. Conclusion: HU of the lung decrease throughout the course of radiation therapy. This change results in a beam overshoot (e.g. 3mm for 6cm of lung traversed) and causes a small dose modification in the overall plan. However, this overshoot does not affect the quality of plans since the margins used in planning, based on proton range uncertainty, are greater. HU needs to change by 150 units before re-planning is warranted.

60 APPLIED LIFE SCIENCES↗

Constraints on {delta}G through Longitudinal Double Spin Asymmetry Measurements of Inclusive Jet Production in Polarized pp Collisions at 200 GeV

We report measurements of the longitudinal double spin asymmetry for inclusive jet production using polarized pp collisions at {radical}(s) = 200 GeV at RHIC. Results from the 2005 and 2006 runs are presented. These results set substantial new constraints on the polarized gluon distribution in the proton over the kinematic range 0.02<x<0.3, when compared to next-to-leading order global analyses of deep inelastic scattering (DIS) data. The first measurement of the transverse single-spin asymmetry for inclusive jets at mid-rapidity is also presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Adaptive frequency comb illumination for interferometry in the case of nested two-beam cavities

The homogeneity test of glass plates in a Fizeau interferometer is hampered by the superposition of multiple interference signals coming from the surfaces of the glass plate as well as the empty Fizeau cavity. To evaluate interferograms resulting from such nested cavities, various approaches such as the use of broadband light sources have been applied. In this paper, we propose an adaptive frequency comb interferometer to accomplish the cavity selection. An adjustable Fabry-Perot resonator is used to generate a variable frequency comb that can be matched to the length of the desired cavity. Owing to its flexibility, the number of measurements needed for the homogeneity test can be reduced to four. Furthermore, compared to approaches using a two-beam interferometer as a filter for the broadband light source, the visibility of the fringe system is considerably higher if a Fabry-Perot filter is applied.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-E-T-177: Clinical Experience with Spirometer Guided Breath Hold Lung SBRT

Purpose: Tumor motion in lung SBRT is typically managed by creating an internal target volume (ITV) based on 4D-CT information. Another option, which may reduce lung dose and imaging artifact, is to use a breath hold (BH) during simulation and delivery. Here we evaluate the reproducibility of tumor position at repeated BH using a newly released spirometry system. Methods: Three patients underwent multiple BH CT’s at simulation. All patients underwent a BH cone beam CT (CBCT) prior to each treatment. All image sets were registered to a patient’s first simulation CT based on local bony anatomy. The gross tumor volume (GTV), and the diaphragm or the apex of the lung were contoured on the first image set and expanded in 1 mm increments until the GTVs and diaphragms on all image sets were included inside an expanded structure. The GTV and diaphragm margins necessary to encompass the structures were recorded. Results: The first patient underwent 2 BH CT’s and fluoroscopy at simulation, the remaining patients underwent 3 BH CT’s at simulation. In all cases the GTV’s remained within 1 mm expansions and the diaphragms remained within 2 mm expansions on repeat scans. Each patient underwent 3 daily BH CBCT’s. In all cases the GTV’s remained within a 2 mm expansions, and the diaphragms (or lung apex in one case) remained within 2 mm expansions at daily BH imaging. Conclusions: These case studies demonstrate spirometry as an effective tool for limiting tumor motion (and imaging artifact) and facilitating reproducible tumor positioning over multiple set-ups and BH’s. This work was partially supported by Qfix.

60 APPLIED LIFE SCIENCES↗

The permeation behavior of deuterium through 1Cr18Ni9Ti stainless steel with TiN+TiC-TiN multiple films

The prevention of tritium losses via permeation through structure components is an important issue in fusion technology. The production of thin layers on materials with low diffusivity and/or low surface recombination constants (so-called permeation barriers) seems to be the most practical method to reduce or hinder the permeation of tritium through materials. TiN+TiC+TiN multiple films are deposited on the surface of 1Cr18Ni9Ti stainless steel by ion-beam assisted deposition technology. The characteristics of films are tested by XPS ASEM and XRD, which shows that the film are compact and uniform with a thickness of about 15 μm, and have a good adherence with the substrate below 773 K. The diffraction peaks in the XRD patterns for TiC and TiN are broadened, implying that the multiple films are deposited on the surface of 1Cr18Ni9Ti stainless steel. Meanwhile, the C-H bonded CH{sub 4}-appears in the infrared spectra of multiple films, suggesting that the CH{sub 4}- is in a static state, so hydrogen atom cannot migrate from the site bonded with carbon to a neighboring site. The measured deuterium permeability in 1Cr18Ni9Ti stainless steel coated with multiple films is 2-3 orders of magnitude lower than that of pure 1Cr18Ni9Ti stainless steel substrate from 473 K to 773 K. However, this barrier is partly destroyed above 773 K.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Generation of Soft X-Ray Radiation in a Compact Free-Electron Laser with Harmonic Multiplication

Single-pass free-electron lasers (FELs) with harmonic multiplication in the X-ray range are studied theoretically with the objective of producing intense radiation with the minimum possible FEL length, beam energy, and seed laser frequency. A cascade FEL with a two-frequency undulator for electron bunching at wavelengths of higher harmonics is proposed. The dynamics of radiation power in a FEL with harmonic multiplication cascades is investigated based on a well-proven phenomenological FEL model that covers all major losses for each harmonic in each FEL cascade. The effect of the beam quality on X-ray generation in a FEL is examined. It is demonstrated that electron beams with energy spread σ{sub e} ≤ 0.0002 are required for efficient use of harmonics in a cascade X-ray FEL. The evolution of power of harmonics in several cascade FELs at wavelengths of ~2–3 nm with multiplication of seed harmonics at a wavelength of 13.51 nm (Mo/Si reflection peak) and 11.43 nm (MoRu/Be reflection peak) is studied. It is demonstrated that the power increases to ~1 GW at a FEL length up to 40 m. In addition, the operation of multicascade FELs with a seed F{sub 2} excimer 157-nm UV laser and harmonics of lasers with CO{sub 2} and C{sub 2}H{sub 2} at 30 nm with a beam of electrons with an energy of ~0.6 GeV and a current of ~1 kА is studied. The power of the modeled X-ray radiation of these FELs at λ = 2.5 and 3.3 nm increases to ~0.5 GW at ~30 m.

43 PARTICLE ACCELERATORS↗

MO-DE-BRA-04: Hands-On Fluoroscopy Safety Training with Real-Time Patient and Staff Dosimetry

Purpose: Fluoroscopically guided interventions (FGI) are routinely performed across many different hospital departments. However, many involved staff members have minimal training regarding safe and optimal use of fluoroscopy systems. We developed and taught a hands-on fluoroscopy safety class incorporating real-time patient and staff dosimetry in order to promote safer and more optimal use of fluoroscopy during FGI. Methods: The hands-on fluoroscopy safety class is taught in an FGI suite, unique to each department. A patient equivalent phantom is set on the patient table with an ion chamber positioned at the x-ray beam entrance to the phantom. This provides a surrogate measure of patient entrance dose. Multiple solid state dosimeters (RaySafe i2 dosimetry systemTM) are deployed at different distances from the phantom (0.1, 1, 3 meters), which provide surrogate measures of staff dose. Instructors direct participating clinical staff to operate the fluoroscopy system as they view live fluoroscopic images, patient entrance dose, and staff doses in real-time. During class, instructors work with clinical staff to investigate how patient entrance dose, staff doses, and image quality are affected by different parameters, including pulse rate, magnification, collimation, beam angulation, imaging mode, system geometry, distance, and shielding. Results: Real-time dose visualization enables clinical staff to directly see and learn how to optimize their use of their own fluoroscopy system to minimize patient and staff dose, yet maintain sufficient image quality for FGI. As a direct result of the class, multiple hospital departments have implemented changes to their imaging protocols, including reduction of the default fluoroscopy pulse rate and increased use of collimation and lower dose fluoroscopy modes. Conclusion: Hands-on fluoroscopy safety training substantially benefits from real-time patient and staff dosimetry incorporated into the class. Real-time dose display helps clinical staff visualize, internalize, and ultimately utilize the safety techniques learned during the training. RaySafe/Unfors/Fluke lent us a portable version of their RaySafe i2 Dosimetry System for 6 months.

60 APPLIED LIFE SCIENCES↗

First Measurements of Inclusive Muon Neutrino Charged Current Differential Cross Sections on Argon at 0.8 GeV Average Neutrino Energy with the MicroBooNE Detector

Current and next-generation precision neutrino oscillation experiments aim to determine the neutrino mass ordering, to measure the extent of CP violation in the lepton sector and to probe beyond Standard Model physics, such as sterile neutrinos. These experiments rely on models for neutrino interactions with matter that are complicated by nuclear effects and final state interactions. To date, these effects cannot be modelled precisely, especially for heavy target nuclei, typically used in modern neutrino experiments. Many future experiments will employ detectors based on the liquid argon time projection chamber technology. As a consequence, neutrino-argon cross-section measurements are of the outmost importance, especially given the relative scarcity of neutrino-argon data, due to the novelty of the technology. This thesis presents the first measurement of muon-neutrino charged-current inclusive cross section on argon at a mean neutrino energy of 0.8 GeV. Data were collected using the MicroBooNE liquid argon time projection chamber in the Fermilab Booster neutrino beam during a period of six months, corresponding to an exposure of $1.6 \times 10^{20}$ protons on target. The measured cross section is presented as a function of the outgoing muon momentum, using multiple Coulomb scattering as a measurement technique, as well as the muon angle with respect to the beam direction. A comparison of the measured cross section obtained with two different configurations of the \textsc{Genie} neutrino event generator is performed, and better agreement is found when using nuclear-effect modelling in the theoretical calculations. Additionally, the total flux integrated cross section is measured to be $0.693 \pm 0.010 \, (\text{stat.}) \pm 0.165 \, (\text{syst.}) \times 10^{-38} \, \text{cm}^{2}$.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Defect-mediated transport and electronic irradiation effect in individual domains of CVD-grown monolayer MoS 2

We study the electrical transport properties of atomically thin individual crystalline grains of MoS 2 with four-probe scanning tunneling microscopy. The monolayer MoS 2 domains are synthesized by chemical vapor deposition on SiO 2 /Si substrate. Temperature dependent measurements on conductance and mobility show that transport is dominated by an electron charge trapping and thermal release process with very low carrier density and mobility. The effects of electronic irradiation are examined by exposing the film to electron beam in the scanning electron microscope in an ultrahigh vacuum environment. The irradiation process is found to significantly affect the mobility and the carrier density of the material, with the conductance showing a peculiar time-dependent relaxation behavior. It is suggested that the presence of defects in active MoS 2 layer and dielectric layer create charge trapping sites, and a multiple trapping and thermal release process dictates the transport and mobility characteristics. The electron beam irradiation promotes the formation of defects and impact the electrical properties of MoS 2 . Finally, our study reveals the important roles of defects and the electron beam irradiation effects in the electronic properties of atomic layers of MoS 2 .

36 MATERIALS SCIENCE↗

ANNIE Phase I: Neutron Background Measurements

The Accelerator Neutrino Neutron Interaction Experiment (ANNIE) is a 26-ton Gd-doped water Cherenkov detector installed in the Booster Neutrino Beam (BNB) at Fermilab. The primary physics goal of ANNIE is to study the multiplicity of final state neutrons from neutrino-nucleus interactions in water. Identifying and counting final state neutrons provides a new experimental handle to study systematic uncertainties related to the neutrino energy reconstruction in oscillation experiments. To achieve that goal ANNIE will make the first use of the novel Large Area Picosecond PhotoDetectors (LAPPDs). In Phase I, ANNIE characterised the beam-correlated neutron backgrounds in the detector and confirmed that they are sufficiently low for the Phase II physics measurements, anticipated to begin in 2019. In these proceesings the methodology and the results of Phase I will be discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Monte Carlo simulation based study of a proposed multileaf collimator for a telecobalt machine

Purpose: The objective of the present work was to propose a design of a secondary multileaf collimator (MLC) for a telecobalt machine and optimize its design features through Monte Carlo simulation. Methods: The proposed MLC design consists of 72 leaves (36 leaf pairs) with additional jaws perpendicular to leaf motion having the capability of shaping a maximum square field size of 35 Multiplication-Sign 35 cm{sup 2}. The projected widths at isocenter of each of the central 34 leaf pairs and 2 peripheral leaf pairs are 10 and 5 mm, respectively. The ends of the leaves and the x-jaws were optimized to obtain acceptable values of dosimetric and leakage parameters. Monte Carlo N-Particle code was used for generating beam profiles and depth dose curves and estimating the leakage radiation through the MLC. A water phantom of dimension 50 Multiplication-Sign 50 Multiplication-Sign 40 cm{sup 3} with an array of voxels (4 Multiplication-Sign 0.3 Multiplication-Sign 0.6 cm{sup 3}= 0.72 cm{sup 3}) was used for the study of dosimetric and leakage characteristics of the MLC. Output files generated for beam profiles were exported to the PTW radiation field analyzer software through locally developed software for analysis of beam profiles in order to evaluate radiation field width, beam flatness, symmetry, and beam penumbra. Results: The optimized version of the MLC can define radiation fields of up to 35 Multiplication-Sign 35 cm{sup 2} within the prescribed tolerance values of 2 mm. The flatness and symmetry were found to be well within the acceptable tolerance value of 3%. The penumbra for a 10 Multiplication-Sign 10 cm{sup 2} field size is 10.7 mm which is less than the generally acceptable value of 12 mm for a telecobalt machine. The maximum and average radiation leakage through the MLC were found to be 0.74% and 0.41% which are well below the International Electrotechnical Commission recommended tolerance values of 2% and 0.75%, respectively. The maximum leakage through the leaf ends in closed condition was observed to be 8.6% which is less than the values reported for other MLCs designed for medical linear accelerators. Conclusions: It is concluded that dosimetric parameters and the leakage radiation of the optimized secondary MLC design are well below their recommended tolerance values. The optimized design of the proposed MLC can be integrated into a telecobalt machine by replacing the existing adjustable secondary collimator for conformal radiotherapy treatment of cancer patients.

60 APPLIED LIFE SCIENCES↗

SU-C-BRC-06: OpenCL-Based Cross-Platform Monte Carlo Simulation Package for Carbon Ion Therapy

Purpose: Monte Carlo (MC) simulation is considered to be the most accurate method for calculation of absorbed dose and fundamental physical quantities related to biological effects in carbon ion therapy. Its long computation time impedes clinical and research applications. We have developed an MC package, goCMC, on parallel processing platforms, aiming at achieving accurate and efficient simulations for carbon therapy. Methods: goCMC was developed under OpenCL framework. It supported transport simulation in voxelized geometry with kinetic energy up to 450 MeV/u. Class II condensed history algorithm was employed for charged particle transport with stopping power computed via Bethe-Bloch equation. Secondary electrons were not transported with their energy locally deposited. Energy straggling and multiple scattering were modeled. Production of secondary charged particles from nuclear interactions was implemented based on cross section and yield data from Geant4. They were transported via the condensed history scheme. goCMC supported scoring various quantities of interest e.g. physical dose, particle fluence, spectrum, linear energy transfer, and positron emitting nuclei. Results: goCMC has been benchmarked against Geant4 with different phantoms and beam energies. For 100 MeV/u, 250 MeV/u and 400 MeV/u beams impinging to a water phantom, range difference was 0.03 mm, 0.20 mm and 0.53 mm, and mean dose difference was 0.47%, 0.72% and 0.79%, respectively. goCMC can run on various computing devices. Depending on the beam energy and voxel size, it took 20∼100 seconds to simulate 10{sup 7} carbons on an AMD Radeon GPU card. The corresponding CPU time for Geant4 with the same setup was 60∼100 hours. Conclusion: We have developed an OpenCL-based cross-platform carbon MC simulation package, goCMC. Its accuracy, efficiency and portability make goCMC attractive for research and clinical applications in carbon therapy.

60 APPLIED LIFE SCIENCES↗