Search NASA⌕ Search

SEARCH · Search NASA

Results for “quantum technologies”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

Plasma dynamics during relativistic S-band magnetron operation

Results of a time- and space-resolved spectroscopic research studies of an S-band relativistic magnetron generating 1.5x10{sup 8} W microwave power at f=2950 MHz, powered by a linear induction accelerator (450 kV, 4 kA, 150 ns), are presented. The cathode plasma electron density and temperature were obtained by analyzing H{sub {alpha}} and H{sub {beta}} hydrogen Ballmer series and carbon C II and C III ion spectral lines and the results of collision radiative modeling. It was shown that the microwave generation is accompanied by a significant increase in plasma density and ion temperature, up to {approx}5x10{sup 16} cm{sup -3} and {approx}8 eV, respectively. The plasma electron temperature was found to be {approx}8 eV. It was shown that the plasma expansion velocity in the axial direction reaches {approx}10{sup 7} cm/s and does not exceed {approx}2x10{sup 5} cm/s in the radial direction. In addition, it was shown that the plasma is not uniform and consists of separate plasma spots whose number increases during the accelerating pulse. Estimates of the plasma transport parameters and its interaction with microwave radiation are also discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modelling and Evaluation of Spectra in Beam Aided Spectroscopy

The evaluation of active beam induced spectra requires advanced modelling of both active and passive features. Three types of line shapes are addressed in this paper: Thermal spectra representing Maxwellian distribution functions described by Gaussian-like line shapes, secondly broad-band fast ion spectra with energies well above local ion temperatures, and, finally, the narrow lines shapes of the equi-spaced Motion Stark multiplet (MSE) of excited neutral beam particles travelling through the magnetic field confining the plasma. In each case additional line shape broadening caused by Gaussian-like instrument functions is taken into account. Further broadening effects are induced by collision velocity dependent effective atomic rates where the observed spectral shape is the result of a convolution of emission rate function and velocity distribution function projected into the direction of observation. In the case of Beam Emission Spectroscopy which encompasses the Motional Stark features, line broadening is also caused by the finite angular spread of injected neutrals and secondly by a ripple in the acceleration voltage associated with high energy neutral beams.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Self-absorption Effects In Experimental Methods Used To Determine Electron Density And Gas Temperature In An Argon Microwave Plasma (SWP) Generated At Atmospheric Pressure

In this work a procedure was applied to verify that self-absorption does not affect the spectral lines used in the experimental determination of the electron density and the gas temperature in surface wave discharges at atmospheric pressure. Therefore, the values of electron density and gas temperature obtained are not perturbed by this phenomenon.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electric micro fields in simulated two component plasmas

The statistical properties of local electric fields in an classical plasma are investigated by molecular dynamics (MD) simulation. Two-component plasma simulations of neutral hydrogen, protons and electrons for intermediate plasma coupling conditions, typically N{sub e}{approx_equal}10{sup 18}cm{sup -3}, T{sub e}{approx_equal}1eV, have been carried out. These simulations appear as a possible and very useful way to generate relevant microfield sample-sets appropriate for ion emitter lineshape simulations for plasma spectroscopy and to provide guidance for line shape modeling.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental Stark Shift of Some Xe II UV Lines

Stark broadening and shift of Xe II lines have been the subject of many experimental and theoretical studie. Here, the results of Stark shift measurements for six Xe II lines are presented. All given results are here reported for the first time. Two lines belong to 5d-6p, two to 5d-7p and one to 5d-4f transition. In this experiment pulsed arc plasma made of mixture of 95% helium and 5% xenon was used. Measured electron densities and temperatures were in the range of (0.2-1.8)10{sup 23}m{sup -3} and 18300-25500 K respectively.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Stark Shift Measurement of Some Xe III Lines

Examination of ionized xenon spectrum is of a great interest for plasma diagnostic purposes, theory testing and different applications. In this paper, we present Stark shift data for one blue and five UV Xe III lines. One line belongs to the 5d-6p transition, while all other lines belong to 6s-6p transition. Most of the existing papers are devoted to Stark width measurements and only one paper deals with shift data of the lines studied herein. A low-pressure pulsed arc with 95% of helium and 5% of xenon was used as a plasma source. All measurements were performed under following plasma conditions: electron density (0.2-1.4)10{sup 23}m{sup -3} and electron temperature 18000-23000 K.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Stark parameters irregularities of Xe II lines obtained by transitions from ({sup 3}P{sub 1})6plevels

Stark widths and shifts of some Xe II lines belonging to the supermultiplets with upper levels ({sup 3}P{sub 1})6p were measured using a pulsed discharge lamp. Plasma parameters, i.e. electron density and temperature, in this experiment were in the range from 0.2 to 1.4x10{sup 23} m{sup -3} and from 18000 to 23000 K, respectively. Lines obtained by transitions from levels ({sup 3}P{sub 1})6p show some strong intra-supermultiplet irregularities in their Stark widths and shifts. These results and the measurements obtained in previous works were used here to analyse the main irregularities that can appear in the case of Xe II. This study may be very useful for obtaining Stark parameters of non-measured lines, using the known parameters of other lines belonging to similar transitions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

On the Stark Widths and Shifts of Ar II 472.68 nm Spectral Line

Stark widths and shifts of Ar II 472.68 nm spectral line were measured from T-tube plasmas. Plasma electron density ranged 1.8-2.210{sup 17} cm{sup -3}, while temperature ranged 20000-43000 K. Obtained results of widths and shifts were compared with measured results of other authors.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Sources for Low Energy Extreme of Ion Implantation

A joint research and development effort focusing on the design of steady state, intense ion sources has been in progress for the past four and a half years. The ultimate goal is to meet the two, energy extreme range needs of mega-electron-volt and 100's of electron-volt ion implanters. This endeavor has resulted in record steady state output currents of higher charge state Antimony and Phosphorous ions: P{sup 2+}(8.6 pmA), P{sup 3+}(1.9 pmA), and P{sup 4+}(0.12 pmA) and 16.2, 7.6, 3.3, and 2.2 pmA of Sb{sup 3+} Sb{sup 4+}, Sb{sup 5+}, and Sb{sup 6+} respectively. During the past year the effort was channeled towards low energy implantation, for which the effort involved molecular ions and a novel plasmaless/gasless deceleration method. To date, 3 emA of positive Decaborane ions were extracted at 14 keV and a smaller current of negative Decaborane ions were also extracted. Additionally, a Boron fraction of over 70% was extracted from a Bernas-Calutron ion source.

43 PARTICLE ACCELERATORS↗

Plasma Doping - Enabling Technology for High Dose Logic and Memory Applications

As logic and memory device dimensions shrink with each generation, there are more high dose implants at lower energies. Examples include dual poly gate (also referred to as counter-doped poly), elevated source drain and contact plug implants. Plasma Doping technology throughput and dopant profile benefits at these ultra high dose and lower energy conditions have been well established [1,2,3]. For the first time a production-worthy plasma doping implanter, the VIISta PLAD tool, has been developed with unique architecture suited for precise and repeatable dopant placement. Critical elements of the architecture include pulsed DC wafer bias, closed-loop dosimetry and a uniform low energy, high density plasma source. In this paper key performance metrics such as dose uniformity, dose repeatability and dopant profile control will be presented that demonstrate the production-worthiness of the VIISta PLAD tool for several high dose applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Indirect Dark Matter Signals

Dark Matter annihilation (DMA) may yield an excess of gamma rays and antimatter particles, like antiprotons and positrons, above the background from cosmic ray interactions. Several signatures, ranging from the positron excess, as observed by HEAT, AMS-01 and PAMELA, the gamma ray excess, as observed by the EGRET spectrometer, the WMAP-haze, and constraints from antiprotons, as observed by CAPRICE, BESS and PAMELA, have been discussed in the literature. Unfortunately, the different signatures all lead to different WIMP masses, indicating that at least some of these interpretations are likely to be incorrect. Here we review them and discuss their relative merits and uncertainties. New x-ray data from ROSAT suggests non-negligible convection in our Galaxy, which leads to an order of magnitude uncertainty in the yield of charged particles from DMA, since even a rather small convection will let drift the charged particles in the halo to outer space.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Model surface conductivity effect for the electromagnetic heat shield in re-entry flight

Effects of model surface conductivity on shock layer enhancement by an applied magnetic field in weakly ionized supersonic plasma flow with a large Hall parameter ({beta}{approx}300) was investigated experimentally. The shock layer structures of test models of two kinds were measured using laser absorption spectroscopy, in the large Hall parameter situation. One was an insulated model; the other was a conductive spherical blunt model. The shock layer enhancement phenomenon by the applied magnetic field was more pronounced for the insulated model than for the conductive model. This tendency agrees with the computational fluid dynamics result, at least qualitatively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of electron irradiation dose on the performance of avalanche photodiode electron detectors

Avalanche photodiodes (APDs) are efficient detectors for electrons with energies below 100 keV. The damaging effects of 8 keV electron beam irradiation on the dark current and the output signal of the APD detector were investigated in this study. The APD dark current increases after electron doses exceeding 1.4x10{sup 13} cm{sup -2}. Preirradiation by high doses of 8 keV electrons further causes a deformation of the pulse height distribution of the APD output in the subsequent detection of low-flux electrons. This effect is particularly prominent when the energy of the detected electrons is lower than that of the damaging electrons. By comparing the experimental data with results of a simulation based on an electron trapping model, we conclude that the degradation of the APD performance is attributable to an enhancement of secondary-electron trapping at irradiation induced defects.

36 MATERIALS SCIENCE↗

Diagnostics of ballistic electrons in a dc/rf hybrid capacitively coupled discharge

The energy distribution of ballistic electrons in a dc/rf hybrid parallel-plate capacitively coupled plasma reactor was measured. Ballistic electrons originated as secondaries produced by ion and electron bombardment of the electrodes. The energy distribution of ballistic electrons peaked at the value of the negative bias applied to the dc electrode. As that bias became more negative, the ballistic electron current on the rf substrate electrode increased dramatically. The ion current on the dc electrode also increased.

36 MATERIALS SCIENCE↗

Measurement and Analysis of Rotational Energy of Nitrogen Molecular Beam by REMPI

Molecular beams are powerful tools for diagnoses of solid surfaces and gas-surface interaction tests. Unfortunately, there are very few reports about experimental analysis of internal energy distribution (e.g. rotational energy) of molecular beams of diatomic or polyatomic molecules, because measurement of internal energy distribution is very difficult. Spectroscopic measurement techniques based on resonantly enhanced multiphoton ionization (REMPI) is very powerful for measurement in highly rarefied gas flows. In this study, the REMPI method is applied to measurement of rotational energy distribution of nitrogen molecular beams. The REMPI spectrum of the molecular beam indicates the rotational temperature higher than the translational temperature of 7.2 K estimated by assuming isentropic flows. The O and P branches of the REMPI spectrum correspond to the rotational temperature of 30 K, but the S branch of the spectrum deviates from that at 30 K. It seems to be because the non-equilibrium rotational energy distribution of the molecular beam deviates from the Boltzmann distribution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pinch Experiments in a Table Top Generator

The design and construction of a table top multipurpose capacitor bank of hundred of Joules and hundred of kiloAmperes conceived to be used in small scale Z-pinch experiments is reported. A recent result on a Z-pinch gas embedded discharge using hollow conical electrodes done in a similar table top generator is also presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and Testing of a Load Current Multiplier on Zebra Facility

The Load Current Multiplier concept (LCM) was validated for the first time on a high-voltage nanosecond pulse-power generator. The designed new device allowed to increase the load current from the nominal 0.8-0.9 MA up to 1.6 MA in static loads with constant inductance and up to 1.4 MA in a planar wire-array plasma loads. These results were achieved without modifying the generator energetic or architecture. LCM allowed both the load magnetic energy increase and the increase of soft X-ray radiation from z-pinch plasmas.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗