At least 1,549 records · Page 86

Exact finite elements for conduction and convection

An appproach for developing exact one dimensional conduction-convection finite elements is presented. Exact interpolation functions are derived based on solutions to the governing differential equations by employing a nodeless parameter. Exact interpolation functions are presented for combined heat transfer in several solids of different shapes, and for combined heat transfer in a flow passage. Numerical results demonstrate that exact one dimensional elements offer advantages over elements based on approximate interpolation functions. Previously announced in STAR as N81-31507

Thornton, E. A.↗

Neptune radio emission - Predictions based on planetary scaling laws

In this paper a prediction is advanced concerning Neptune's low-frequency radio emission based on the radiometric Bode's law for radio planets in combination with the magnetostrophic scaling law for magnetized planets. The total emitted radio power is predicted to be about 1.6 x 10 to the 7th W, very nearly the same as that predicted and observed for Uranus. Possible emission spectral shapes, based on Saturn and earth-like models, are shown. Using these models, the radio emission frequency range is predicted to extend from approximately 100 to just over 1000 kHz, with a spectral peak between 350 and 500 kHz. If radiation is beamed approximately in the sunward direction, Neptune should be detectable by the planetary radio astronomy experiment onboard the Voyager spacecraft sometime between 45 and 90 days before closest approach. This detection is likely to represent the first direct evidence of a Neptune magnetic field. Possible implications for Neptune's magnetosphere with regard to the time of first detection are discussed.

Desch, Michael D.↗

Problems in determining the surface density of the Galactic disk

A new method is presented for determining the local surface density of the Galactic disk from distance and velocity measurements of stars toward the Galactic poles. The procedure is fully three-dimensional, approximating the Galactic potential by a potential of Staeckel form and using the analytic third integral to treat the tilt and the change of shape of the velocity ellipsoid consistently. Applying the procedure to artificial data superficially resembling the K dwarf sample of Kuijken and Gilmore (1988, 1989), it is shown that the current best estimates of local disk surface density are uncertain by at least 30 percent. Of this, about 25 percent is due to the size of the velocity sample, about 15 percent comes from uncertainties in the rotation curve and the solar galactocentric distance, and about 10 percent from ignorance of the shape of the velocity distribution above z = 1 kpc, the errors adding in quadrature. Increasing the sample size by a factor of 3 will reduce the error to 20 percent. To achieve 10 percent accuracy, observations will be needed along other lines of sight to constrain the shape of the velocity ellipsoid.

Statler, Thomas S.↗

Measured and predicted shock shapes for AFE configuration at Mach 6 in air and in CF4

Shock shapes and stand-off distances were obtained for the Aeroassist Flight Experiment configuration from Mach 6 tests in air and in CF4. Results were plotted for an angle-of attack range from -10 to 10 degrees and comparisons were made at selected angles with inviscid-flow predictions. Tests were performed in the Langley Research Center (LaRC) 20 inch Mach 6 Tunnel (air) at unit free-stream Reynolds numbers (N sub Re, infinity) of 2 million/ft and 0.6 million/ft and in the LaRC Hypersonic CF4 Tunnel at N sub Re, infinity = 0.5 million/ft and 0.3 million/ft. Within the range of these tests, N sub Re, infinity did not affect the shock shape or stand off distance, and the predictions were in good agreement with the measurements. The shock stand-off distance in CF4 was approximately half of that in air. This effect resulted from the differences in density ratio across the normal shock, which was approximately 12 in CF4 and 5 in air. In both test gases, the shock lay progressively closer to the body as angle of attack decreased.

Wells, William L.↗

Comments on the statistical analysis of excess variance in the COBE differential microwave radiometer maps

Cosmic anisotrophy produces an excess variance sq sigma(sub sky) in the Delta maps produced by the Differential Microwave Radiometer (DMR) on cosmic background explorer (COBE) that is over and above the instrument noise. After smoothing to an effective resolution of 10 deg, this excess sigma(sub sky)(10 deg), provides an estimate for the amplitude of the primordial density perturbation power spectrum with a cosmic uncertainty of only 12%. We employ detailed Monte Carlo techniques to express the amplitude derived from this statistic in terms of the universal root mean square (rms) quadrupole amplitude, (Q sq/RMS)(exp 0.5). The effects of monopole and dipole subtraction and the non-Gaussian shape of the DMR beam cause the derived (Q sq/RMS)(exp 0.5) to be 5%-10% larger than would be derived using simplified analytic approximations. We also investigate the properties of two other map statistics: the actual quadrupole and the Boughn-Cottingham statistic. Both the sigma(sub sky)(10 deg) statistic and the Boughn-Cottingham statistic are consistent with the (Q sq/RMS)(exp 0.5) = 17 +/- 5 micro K reported by Smoot et al. (1992) and Wright et al. (1992).

Wright, E. L.↗

First-Generation Jet Propulsion Laboratory "Hockey-Puck" Free-Flying Magnetometers for Distributed In-Situ Multiprobe Measurement of Current Density Filamentation in the Northern Auroral Zone: Enstrophy Mission

The sub-orbital rocket mission was a collaborative project between the University of New Hampshire, Cornell University, and the Jet Propulsion Laboratory (JPL) to study filamentation phenomena in the northern Auroral zone. The Enstrophy mission test flies the JPL Free-Flying Magnetometer (FFM) concept. The FFM technology development task has been funded by NASA develop miniaturized, low-power, integrated "sensorcrafts". JPL's role was to design, integrate, test, and deliver four FFMs for deployment from the sounding rocket, allowing a unique determination of curl-B. This provides a direct measurement of magnetic-field-aligned current density along the rocket trajectory. A miniaturized three-axis fluxgate magnetometer was integrated with a 4-channel 22-bit sigma-delta Analog to Digital Converter (ADC), four temperature sensors, digital control electronics, seven (Li-SOCl2) batteries, two (4 deg x 170 deg field of view) sun-sensors, a fan-shaped-beam laser diode beacon, a (16 MHz) stable Temperature Compensated Crystal Oscillator (TCXO) clock, Radio Frequency (RF) communication subsystem, and an antenna for approximately 15 minutes of operation where data was collected continuously and transmitted in three (3) bursts (approximately 26 seconds each) to ground station antennas at Poker Flat, Alaska. FFMs were stowed within two trays onboard the rocket during the rocket launch and were released simultaneously using the spinning action of the rocket at approximately 300 km altitude (approximately 100 sec. into the flight). FFMs were deployed with spin rate of approximately 17 Hz and approximately 3 m/sec linear velocity with respect to the rocket. For testing purposes while the rocket was in the launch pad and during flight prior to release of FFMs from the rocket, commands (such as "power on", "test", "flight", "power off', and clock "Reset" signal) were transmitted via a infrared Light Emitting Diode to an infrared detector in the FFM. Special attention was paid to low magnetic signature electronic design and choice of materials in packaging. The miniaturized fluxgate magnetometers had a range of 1-60000 nT with 0.1% full-scale linearity. The frequency range of interest for magnetic measurement was 10 mHz - 50 Hz. Digital data from the magnetometer's three axes were placed in a 4MB Static Random Access Memory (SRAM) in data packages (frames) formatted together with time tags and frame ID. After a specified time was elapsed, the data were Viterbi encoded and transmitted at a rate of 100 kbps (BPSK). Each of the four FFMs transmitted at different frequency. These carrier frequencies were in the range of 2200-2300 MHz. The antenna was a single patch on a high dielectric constant substrate covering one end-plate of the hockey-puck-sized unit. The local clocks aboard the FFMs were reset at the start of the mission and stayed synchronized within 3 msec during the mission. Position of each FFM with respect to the rocket is calculated by the knowledge of its release velocity (measured at exit point of the FFM launcher tract) providing an accuracy of 1 m over the maximum range of 3 km. Spatial and temporal nature of observants can be separated to within 3 m in space or 3 msec time interval.

Javadi, H.↗

A Proposed Landing Site for the 2001 Lander in a Hematite-Rich Region in Sinus Meridiani

The Thermal Emission Spectrometer (TES) instrument on the Mars Global Surveyor (MGS) mission has identified an accumulation of crystalline hematite (alpha-Fe2O3) that covers an area with very sharp boundaries approximately 350 by 350-750 km in size centered near 2 S latitude between 0 and 5 W longitude (Sinus Meridiani). The depth and shape of the hematite fundamental bands in the TES spectra show that the hematite is relatively coarse grained (> 5-10 microns). The spectrally-derived areal abundance of hematite varies with particle size from approx. 10% for particles > 30 microns in diameter to 40-60% for unpacked 10 micron powders. The hematite in Sinus Meridiani is thus distinct from the fine-grained (diameter < 5-10 microns), red, crystalline hematite considered, on the basis of visible and near-IR data, to be a minor spectral component in Martian bright regions. A map of the hematite index has been constructed using TES data from 11 orbits, including the six in which hematite was detected and five orbits that passed nearby that showed no evidence of hematite. The boundaries of the hematite-rich region are sharp at spatial scales of about 10 km. Within this region there are spatial variations in spectral band depth of a factor of two to three. At the present time the hematite-rich region has not been completely mapped. However, by using the bounding orbits to the east and west in which hematite was not detected, we can establish that this region covers an area that is between 350 and 750 km in length and over -350 km in width (1.2 x 10(exp 5) to 2.6 x 10(exp 5 sq km). The hematite-rich surface discovered by TES closely corresponds with smooth-surfaced unit ('sm') that appears to be the surface of a layered sequence. The presence of small mesas superposed on 'sm' and the degraded nature of the small impact craters suggests that material has been removed from this unit. These layered materials do not appear to be primary volcanic products (i.e., lava flows) because there are no associated lava flow lobes, fronts or pressure ridges; there are no fissures or calderae, nor any other features that can be interpreted as volcanic within 'sm'. Bowl-shaped depressions in 'sm' and the remnant mesas on top of a portion of this unit suggest that deflation has removed material that was once above the present surface of 'sm'. The most likely cause of the deflation is wind, which suggests that the layered materials are relatively friable. In summary, Sinus Meridiani hematite is closely associated with a smooth, layered, friable surface that is interpreted to be sedimentary in origin.

Christensen, Philip R.↗

Aerodynamics of Stardust Sample Return Capsule

Successful return of interstellar dust and cometary material by the Stardust Sample Return Capsule requires an accurate description of the Earth entry vehicle's aerodynamics. This description must span the hypersonic-rarefied, hypersonic-continuum, supersonic, transonic, and subsonic flow regimes. Data from numerous sources are compiled to accomplish this objective. These include Direct Simulation Monte Carlo analyses, thermochemical nonequilibrium computational fluid dynamics, transonic computational fluid dynamics, existing wind tunnel data, and new wind tunnel data. Four observations are highlighted: 1) a static instability is revealed in the free-molecular and early transitional-flow regime due to aft location of the vehicle s center-of-gravity, 2) the aerodynamics across the hypersonic regime are compared with the Newtonian flow approximation and a correlation between the accuracy of the Newtonian flow assumption and the sonic line position is noted, 3) the primary effect of shape change due to ablation is shown to be a reduction in drag, and 4) a subsonic dynamic instability is revealed which will necessitate either a change in the vehicle s center-of-gravity location or the use of a stabilizing drogue parachute.

Mitcheltree, R. A.↗

X-ray Computed Tomography of Irradiated and Unirradiated AGR-3/4 Compacts

X-ray Computed Tomography (XCT) has been utilized to image and characterize compacts from the combined third and fourth irradiation of the Advanced Gas Reactor (AGR) Program, AGR-3/4, fuel. The experiment contained tristructural isotropic (TRISO)-coated fuel particles as well as designed-to-fail (DTF) fuel particles. Two irradiated compacts, representing the lower and higher range of AGR-3/4 burnup (4.85% and 14.92% fissions per initial heavy metal atom FIMA) were examined. These represent the first known highly irradiated TRISO fuel compacts to be examined via X-ray CT. Additionally, two unirradiated compacts from the same production batch as the examined irradiation compacts were also imaged for a baseline comparison. As XCT of irradiated TRISO compacts is not a commonly implemented characterization technique, a significant portion of the report focuses on developed methodology and imaging conditions. A specialized sample shielding device was developed and fabricated specifically to limit received dose to staff during sample preparation for XCT and to minimize excess gamma radiation dose to sensitive electronic components with the utilized X-ray system. Significant penetration through the uranium oxycarbide fuel kernels by significantly hardening the X-ray beam with specialized proprietary filters acquired from Carl Zeiss NTS Ltd. The filter utilized resulted in an average X ray photon energy of ~110 keV which approaches uranium’s K-edge (~115 keV), maximizing penetration for a microfocus X-ray source. The gamma-radiation emitted from the irradiated AGR-3/4 TRISO compacts, has the same properties and mechanisms for interaction with matter as X-rays, thus the detection of gamma-radiation by the utilized X-ray detectors was initially a concern. However, although ?-rays did produce an observable signal on the X-ray detector, its contribution to the overall imaging results appeared negligible upon 3D reconstruction. The neglibile impact on the resulting 3D reconstructed volumes were likely the result of: (1) a significantly lower detection efficiency for ?-rays relative to X-rays; (2) An X-ray flux at the detector several orders of magnitude higher than that of the impinging ?-rays from the irradiated compacts. These results suggest that irradiated compacts with significantly higher radiation fields can be examined in the future if an acceptable route for sample handling and preparation can be determined. Additionally, the 3D imaging results of XCT can provide a valuable means of assessing compacts. While in many ways complimentary to traditional post irradiation examination techniques such as optical ceramography, XCT can provide additional insight into compact features traditionally difficult to discern directly from cross-sectional imaging alone. Preliminary analyses on kernel size, morphology (aspect ratio and sphericity), and kernel orientation were presented. Sphericity, a simple morphological shape descriptor, was utilized to screen for kernel extrusions within the high burnup compact. The number of kernel extrusions identified via XCT represented an approximate two-fold increase from the quantity of extruded particles observed (via optical ceramography) in adjacent compacts from the same irradiation capsule. While numerical analysis of the compact datasets was highly preliminary, initial results show promise for providing complimentary metrics to current AGR-3/4 PIE and potentially additional insight into the processes driving TRISO fuel degradation during reactor operation. Additional analyses to be performed at a later date include a more detailed examination of kernel size, kernel sphericity (and observed kernel extrusions), and sphericity. Given all particles can be observed in a single data volume possible correlation of spatial position with observed kernel features will also be made at a later date.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Shape optimization of a printed-circuit heat exchanger to enhance thermal-hydraulic performance

Printed circuit heat exchanger (PCHE) is recently considered as a recuperator for the high temperature gas cooled reactor. In this work, the zigzag-channels of a PCHE have been optimized by using three-dimensional Reynolds-Averaged Navier-Stokes (RANS) analysis and response surface approximation (RSA) modeling technique to enhance thermal-hydraulic performance. Shear stress transport turbulence model is used as a turbulence closure. The objective function is defined as a linear combination of the functions related to heat transfer and friction loss of the PCHE, respectively. Three geometric design variables viz., the ratio of the radius of the fillet to hydraulic diameter of the channels, the ratio of wavelength to hydraulic diameter of the channels, and the ratio of wave height to hydraulic diameter of the channels, are used for the optimization. Design points are selected through Latin-hypercube sampling. The optimal design is determined through the RSA model which uses RANS derived calculations at the design points. The results show that the optimum shape enhances considerably the thermal-hydraulic performance than a reference shape. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Signature of 0 + excited state and shape coexistence in 94 Kr through 93 Kr(d,p) 94 Kr reaction

A measurement of the excitation spectrum of 94 Kr via one-neutron transfer to the ground state of 93 Kr using the 93 Kr(d,p) 94 Kr reaction at 8A MeV, observing the outgoing protons, performed with the IRIS facility at TRIUMF is reported. Two states in 94 Kr, at 1.50±0.14 MeV and 2.20±0.14 MeV, were observed. An adiabatic-wave approximation analysis of the differential cross sections leads us to identify the lower energy state as being populated with neutron transfer to the 3 s1/2 orbital. This leads to the first observation of the lowest 0 + excited state in 94 Kr, hence signaling shape co-existence. Theoretical calculations performed within the in-medium similarity renormalization group framework are presented that also show the existence of a low-energy 0 + state, aligning qualitatively with the observation.

74 ATOMIC AND MOLECULAR PHYSICS↗

Astigmatic electron beam propagation

An astigmatic electron beam with an ellipticity ratio of approximately 2:1 was examined using the Enhanced Modified Faraday Cup (EMFC) diagnostic to measure its properties and show how the power density distribution varies near the beam waist. Results show that the beam has two power density peaks, one on either side of the beam crossover point, resulting from different focal distances of the major and minor axes of the elliptical beam shape. Quantification of the beam properties was used to establish a depth-of-field where the beam diameter and peak power densities are relatively constant. For the 1 kW beam studied here, the depth-of-field measured approximately ±5 mm from the beam crossover point, illustrating how electron beam diagnostics can be used to identify process control limits for repeatable and reliable welds under non-ideal electron beam power density distribution conditions.

36 MATERIALS SCIENCE↗

Fourth order expressions for the electronic absorption lineshape of molecular excitons

The line shape of electronic absorption spectroscopy reflects the information on quantum dynamical processes accompanying the electronic excitation, and its accurate description is an important component for validating theoretical models and assumptions. The present work provides detailed expressions for the absorption line shape of molecular excitons that are valid up to the fourth order of exciton-bath interactions within the quantum master equation approach. These expressions can serve as the basis for developing general and systematic methods to model the line shape for a broad class of molecular exciton systems and environments. For the bath model of linearly coupled harmonic oscillators, more detailed expressions employing the spectral densities of the bath are presented. These expressions are then tested for a linear aggregate of identical chromophores each coupled to the harmonic oscillator bath. Finally, calculation results for a super-Ohmic spectral density with exponential cutoff demonstrate the feasibility of calculations and also offer insights into the utility and difficulty of going beyond the second order approximation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-E-T-291: Sensitivity of a Simple 2D EPID in Vivo Dosimetry

Purpose: As radiotherapy (RT) increases in complexity, so does motivation for in vivo dosimetry (IVD), which may detect errors such as: setup, beam shaping and dose delivered. We have recently developed an easy-toimplement method for two-dimensional IVD based on images taken with the electronic portal imaging device (EPID) in cine mode during treatment. The purpose of this work is to characterize its sensitivity to possible RT delivery errors. Methods: We introduced a series of modifications to a simple RT field (10×10, 100MU, 300RR, 20cm homogeneous phantom) to simulate errors. These modifications included multi-leaf collimator (MLC) position, number of MUs, and collimator angle. We quantified the sensitivity to inhomogeneities by inserting variable amounts of solid lung and bone. Finally we delivered realistic fields to an anthropomorphic phantom to estimate sensitivity to gantry angle and setup errors. Results: Our EPIDIVD is sensitive to MLC positioning errors of 1mm and 3mm in the closed and open directions respectively, and to 3% MU variations. Sensitivity to collimator angle depends on field shape irregularity; in the case of a 10x10 field, we are sensitive to errors of 0.8°. The sensitivity to inhomogeneities is limited by the nature of MV imaging: approximately 1% signal change is noted when switching 5cm of water to equal amounts of bone or lung. This suggests that the EPID-IVD is likely not sensitive to small setup or gantry angle errors, as confirmed by anthropomorphic tests. Conclusion: We have characterized a simple method of 2D dose reconstruction at isocenter depth inside the patient, which is sensitive to possible RT delivery errors. This method may be useful as a secondary safety check, to prevent large errors from being carried on to following fractions, and to record delivered dose. By using readily available hardware, it is easily implemented and may prove especially useful in centers with limited resources.

60 APPLIED LIFE SCIENCES↗

Joining and Assembly of Bulk Metallic Glass Composites Through Capacitive Discharge

Bulk metallic glasses (BMGs), a class of amorphous metals defined as having a thickness greater than 1 mm, are being broadly investigated by NASA for use in spacecraft hardware. Their unique properties, attained from their non-crystalline structure, motivate several game-changing aerospace applications. BMGs have low melting temperatures so they can be cheaply and repeatedly cast into complex net shapes, such as mirrors or electronic casings. They are extremely strong and wear-resistant, which motivates their use in gears and bearings. Amorphous metal coatings are hard, corrosion-resistant, and have high reflectivity. BMG composites, reinforced with soft second phases, can be fabricated into energy-absorbing cellular panels for orbital debris shielding. One limitation of BMG materials is their inability to be welded, bonded, brazed, or fastened in a convenient method to form larger structures. Cellular structures (which can be classified as trusses, foams, honeycombs, egg boxes, etc.) are useful for many NASA, commercial, and military aerospace applications, including low-density paneling and shields. Although conventional cellular structures exhibit high specific strength, their porous structures make them challenging to fabricate. In particular, metal cellular structures are extremely difficult to fabricate due to their high processing temperatures. Aluminum honeycomb sandwich panels, for example, are used widely as spacecraft shields due to their low density and ease of fabrication, but suffer from low strength. A desirable metal cellular structure is one with high strength, combined with low density and simple fabrication. The thermoplastic joining process described here allows for the fabrication of monolithic BMG truss-like structures that are 90% porous and have no heat-affected zone, weld, bond, or braze. This is accomplished by welding the nodes of stacked BMG composite panels using a localized capacitor discharge, forming a single monolithic structure. This removes many complicated and costly fabrication steps. Moreover, the cellular structures detailed in this work are among the highest- strength and most energy-absorbent materials known. This implies that a fabricated structure made from these materials would have unequaled mechanical properties compared to other metal foams or trusses. The process works by taking advantage of the electrical properties of the matrix material in the metal-matrix composite, which in this case is a metallic glass. Due to the random nanoscale arrangement of atoms (without any grain boundaries), the matrix glass exhibits a near-constant electrical resistivity as a function of temperature. By placing the composite panels between two copper electrode plates and discharging a capacitor, the entire matrix of the panel can be heated to approximately 700 C in 10 milliseconds, which is above the alloy s solidus but below the liquidus. By designing the geometry of the panels into the shape of an egg box, the electrical discharge localizes only in the tips of each pyramidal cell. By applying a forging load during discharge, the nodes of the panels can be fused together into a single piece, which then dissipates heat through radiation back into a glassy state. This means that two panels can be metallurgically fused into one panel with no heat-affected zone, creating a seamless connection between panels. During the process, the soft metal particles (dendrites) that are uniformly distributed in the glassy matrix to increase the toughness are completely unaffected by the thermoplastic joining. The novelty is that a truss (or foam-like) structure can be formed with excellent energy- absorbing capabilities without the need for machining. The technique allows for large-scale fabrication of panels, well-suited for spacecraft shields or military vehicle door panels. Crystalline metal cellular structures cannot be fabricated using the thermoplastic joining technique described here. If metal panels were te assembled into a cellular structure, they would either have to be welded, brazed, bonded, or fastened together, creating a weak spot in the structure at each connection. Welded parts require a welding material to be added to the joint and exhibit a soft and weak heat-affected zone. Brazing and bonding do not form a metallurgical joint and thus exhibit low strengths, especially when the panels are pulled apart and fasteners require high-stress-concentration holes to be drilled. No equivalent rapid heating method exists for assembling metal panels together into cellular structures, and thus, those parts must be foamed, machined, or investment cast if they are to form a monolithic structure. If the crystalline panels were to be joined using capacitive discharge, as with a spot welder, their bond would be very weak, and the panels would have to be extremely thin. In contrast, the strength of joined BMG parts has been demonstrated to have strength comparable to the parent material. This technique opens up the possibility of using large-scale BMG hardware in spacecraft, military, or commercial applications.

Hofmann, Douglas C.↗

Low-energy electron scattering from C{sub 4}H{sub 9}OH isomers

We present differential, integral, and momentum-transfer cross sections for elastic scattering of low-energy electrons by three butanol isomers, isobutanol, t-butanol, and 2-butanol. Our results were calculated with the Schwinger multichannel method in the static-exchange plus polarization approximation for collision energies from 1 to 50 eV. The present results are compared with previous calculations and measurements for the remaining C{sub 4}H{sub 9}OH isomer, n-butanol [Khakoo et al., Phys. Rev. A 78, 062714 (2008)]. Distinctive behavior is observed in the differential cross sections at collision energies between 5 and 10 eV. In particular, whereas n-butanol exhibits an f-wave scattering pattern, the other isomers exhibit d-wave behavior. A similar pattern is found in the related alkanes when comparing straight-chain versus branched isomers. We discuss the possible connection of this behavior to shape resonances that influence the scattering.

74 ATOMIC AND MOLECULAR PHYSICS↗

Femtoscopic correlations of identical charged pions and kaons in $pp$ collisions at $\sqrt{s}$ = 13 TeV with event-shape selection

Collective behavior has been observed in high-energy heavy-ion collisions for several decades. Collectivity is driven by the high particle multiplicities that are produced in these collisions. At the CERN Large Hadron Collider (LHC), features of collectivity have also been seen in high-multiplicity proton-proton collisions that can attain particle multiplicities comparable to peripheral Pb-Pb collisions. One of the possible signatures of collective behavior is the decrease of femtoscopic radii extracted from pion and kaon pairs emitted from high-multiplicity collisions with increasing pair transverse momentum. This decrease can be described in terms of an approximate transverse mass scaling. In the present work, femtoscopic analyses are carried out by the ALICE Collaboration on charged pion and kaon pairs produced in pp collisions at $\sqrt{s}$=13TeV from the LHC to study possible collectivity in pp collisions. The event-shape analysis method based on transverse sphericity is used to select for spherical versus jetlike events, and the effects of this selection on the femtoscopic radii for both charged pion and kaon pairs are studied. This is the first time this selection method has been applied to charged kaon pairs. An approximate transverse-mass scaling of the radii is found in all multiplicity ranges studied when the difference in the Lorentz boost for pions and kaons is taken into account. This observation does not support the hypothesis of collective expansion of hot and dense matter that should only occur in high-multiplicity events. A possible alternate explanation of the present results is based on a scenario of common emission conditions for pions and kaons in pp collisions for the multiplicity ranges studied.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Status of Electronics Upgrades to the LANL Green is Clean Phoswich Detector Systems - 16419

Los Alamos National Laboratory radiological facilities produce low-density room trash that, in many cases, is not contaminated with radioactivity. It has been estimated that 50 to 90% of low-density room trash is free of radioactive contamination and eligible for inclusion in LANL's Green is Clean (GIC) program. The GIC program is a verification program for non-regulated waste from radiation controlled areas that has been actively segregated as nonradioactive through the use of the waste generator's acceptable knowledge. The GIC program has employed two large area Phoswich gamma ray detector systems (HERCULES and ZEUS) to assay and verify that GIC candidate waste meets free release disposal requirements. The large area (127 cm{sup 2}) Phoswich detectors consist of a thin NaI front crystal (3 mm thick) that is optically coupled to a thick CsI back crystal (50 mm thick). The crystals are set in an oxygen-free high-conductivity copper housing with a very thin (0.025 mm) aluminum entrance window. The scintillation properties of the two crystals are different enough to allow the system's electronic components to identify the origin of any pulse. The original systems utilize Nuclear Instrumentation Module (NIM) electronics to process the detector signals. These electronic modules provide the buffering, amplification, and pulse shape analyzer needed for the proper presentation of signals to the custom Phosmux router module. The router module separates the sodium iodide and cesium iodide signals by their rise times and transfers this information into the computer-mounted multichannel analyzer, a Canberra Model S-100 system. While these NIM Bin counting electronics configurations have been effective for approximately 20 years of operation, they are bulky requiring numerous modules per detector and the important Phosmux module is no longer manufactured by LANL. Modern advancement of commercial counting electronics now offer more compact options for equivalent detector signal processing. A pulse shape discriminator module, the DGF Pixie-4, made by XIA LLC, has been identified that can replace the majority of the original NIM bin electronics in a much more compact chassis - one Pixie-4 replaces four NIM amplifiers and four NIM PSAs and fits in a small National Instruments{sup TM} chassis. Thus, LANL has initiated a system upgrade project to replace the historic NIM electronics with the XIA Pixie4 and associated configuration software. The hardware for one Phoswich systems has been procured for the project and the configuration software, customized for the LANL Phoswich detector application, has been written by the manufacturer. Initial setup and optimization of the Pixie-4 configuration has been performed. Qualitative and quantitative baseline comparisons to the NIM electronics has been performed. Good agreement of key low energy gamma lines between the systems has allowed 'Proof of Concept' to be concluded. Further optimization and performance evaluations are in progress. Modifications to the LabVIEW{sup TM} based operating software (originally written by VI Control Systems Ltd.) are being performed by a LANL LabVIEW{sup TM} programmer to accommodate the electronics upgrade. A new LabVIEW{sup TM} interface to control the Pixie-4 has already been developed. Final optimization and testing, formal software QA, and revisions to operating procedures are in progress to achieve completion of the GIC system upgrade project. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗