Search NASA⌕ Search

SEARCH · Search NASA

Results for “source configuration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

Evaluation of diffuse-illumination holographic cinematography in a flutter cascade

Since 1979, the Lewis Research Center has examined holographic cinematography for three-dimensional flow visualization. The Nd:YAG lasers used were Q-switched, double-pulsed, and frequency-doubled, operating at 20 pulses per second. The primary subjects for flow visualization were the shock waves produced in two flutter cascades. Flow visualization was by diffuse-illumination, double-exposure, and holographic interferometry. The performances of the lasers, holography, and diffuse-illumination interferometry are evaluated in single-window wind tunnels. The fringe-contrast factor is used to evaluate the results. The effects of turbulence on shock-wave visualization in a transonic flow are discussed. The depth of field for visualization of a turbulent structure is demonstrated to be a measure of the relative density and scale of that structure. Other items discussed are the holographic emulsion, tests of coherence and polarization, effects of windows and diffusers, hologram bleaching, laser configurations, influence and handling of specular reflections, modes of fringe localization, noise sources, and coherence requirements as a function of the pulse energy. Holography and diffuse illumination interferometry are also reviewed.

Decker, A. J.↗

High sensitivity boundary layer transition detector

A high sensitivity differential interferometer has been developed to locate the region where the boundary layer flow changes from laminar to turbulent. Two experimental configurations have been used to evaluate the performance of the interferometer, open shear layer configuration and wind tunnel turbulent spot configuration. In each experiment small temperature fluctuations were introduced as the signal source. Simultaneous cold wire measurements have been compared with the interferometer data. The comparison shows that the interferometer is sensitive to very weak phase variations in the order of .001 the laser wavelength.

Azzazy, M.↗

Spectroscopic evidence for infall around an extraordinary IRAS source in Ophiuchus

Millimeter-wave continuum observations and spectral line observations of the J = 5-4 and J = 2-1 transitions of CS toward IRAS 16293-2422, an extremely cold infrared source associated with a high-velocity molecular outflow in the Rho Ophiuchi molecular cloud, are reported. The observations indicate that this source is a dust-enshrouded object embedded in a dense, elongated configuration of molecular gas whose major axis is roughly orthogonal to the direction of the double bipolar outflow observed in it. The observations appear to provide spectroscopic evidence for significant mass infall motions associated with a young stellar object, and suggest that IRAS 16293-2422 is a true protostar.

Walker, Christopher K.↗

A high resolution spectrometer for EUV/FUV wavelengths

The most efficient of the various configurations considered for a high-resolution spaceborne spectrometer for point-source astronomy in the 400-1200-A wavelength region which will fit within an envelope defined by the projected Spartan space platform is a multiple Rowland circle spectrograph, with each of four toroidal gratings respectively intercepting a fraction of the primary mirror beam. Each spectrometer can accept a rather slowly diverging beam, reducing grating aberrations, without further efficiency loss due to additional reflections or magnification. The line densities, detector size, pixel size, etc., of the detector for this instrument are dependent on the drift rate of the space platform; a design optimized for an uncorrected 4-arcsec drift is presented.

Hurwitz, Mark↗

High-sensitivity density fluctuation detector

A high-sensitivity differential interferometer has been developed to detect small density fluctuations over an optical path length of the order of the boundary layer thickness near transition. Two experimental configurations have been used to evaluate the performance of the interferometer: an open shear-layer configuration and a wind-tunnel turbulent spot configuration. In each experiment small temperature fluctuations were introduced as the signal source. Simultaneous cold-wire measurements have been compared with the interferometer data. The comparison shows that the interferometer is sensitive to very weak phase variations of the order of 0.001 of the laser wavelength.

Azzazy, M.↗

The Role of Magnetograms in Testing Models of Coronal Mass Ejections

A general review of current and future magnetographic capabilities is presented with emphasis on how they address observational predictions of CME models (e.g., the model/observation matrix developed in the SHINE 2000 workshop). Existing line-of-sight magnetographs can observe certain structural and kinematic properties of CME source regions when they are on the visible disk. These include polarity configuration, location and structure of the magnetic inversion line, proper motions of magnetic elements, and time variation of flux. Additional chromospheric magnetograms provide information on how the field spreads with height and, if properly sequenced with photospheric magnetograms, can determine whether flux is emerging or submerging. Vector magnetographs can provide information about currents and magnetic shear but will only begin to attain the spatial and temporal coverage appropriate to CMEs with the advent of the SOLIS vector spectromagnetograph and, hopefully, its copies at several widely spaced longitudes. Important additions to the SHINE 2000 matrix are required to define an observational program. These include spatial and temporal resolutions and extents as well as needed sensitivity.

Jones, Harrison P.↗

Nanoscale wicking methods and devices

A fluid transport method and fluid transport device are disclosed. Nanoscale fibers disposed in a patterned configuration allow transport of a fluid in absence of an external power source. The device may include two or more fluid transport components having different fluid transport efficiencies. The components may be separated by additional fluid transport components, to control fluid flow.

Zhou, Jijie↗

Signals of Opportunity - Airborne Demonstrator (SoOP-AD): Instrument Overview, Performance During First Flights and Future Instrument Concept

The Signals of Opportunity Airborne Demonstrator (SoOp-AD) was developed as part of the NASA InstrumentIncubator Program (IIP) with the goal of maturing the use of SoOp from existing communication satellites in geostationaryorbit, operating within the heavily used P-band (under 500 MHz) spectrum for soil moisture observations. P-band offers the benefit of roughly five (5) times deeper soil penetration compared to conventional L-band methods. SoOp-AD operates in a bi-static radar configuration, and only requires reception of direct and scattered signals from the source satellite. In this paper we present an overview of the SoOp-AD instrument architecture, signal processing, internal calibration approach and preliminary results from flights over the Little Washita watershed in Oklahoma, USA. Finally, future steps towards a U-class ("cubesat") instrument concept based upon experience with the airborne demonstrator are presented.

Instrumentation and Photography↗

On the Characterization and Mitigation of Noise in Space-borne Microwave Sounding Instruments

Space-borne microwave sounding instruments have become vital data sources for weather prediction and climate change studies. Among the various radiometer configurations, the total power microwave radiometer is particularly appealing for current and future operational satellites due to its superior sensitivity and simple design. However, its performance is vulnerable to degradation caused by receiver gain fluctuations, electronic 1/f noise, and other time varying receiver characteristics. For Numerical Weather Prediction (NWP) users, 1/f noise introduces inter-channel correlations, complicating the assimilation of affected observations and reducing their accuracy. Addressing this noise issue in ground data processing system is essential to enhance the utility of microwave sounding data. This paper focuses on the characterization and mitigation of noise in current and future microwave sounding instruments, with particular emphasis on the impact of 1/f noise. Various methods are applied to quantitatively characterize noise features in both frequency and time domains. Additionally, the influence of calibration parameters on 1/f noise are analyzed. Based on these findings, we propose a mitigation algorithm for reducing noise during the on-orbit calibration of microwave sounding instruments, aiming to improve the quality of retrieved data for operational use.

calibration↗

Radiograph and passive data analysis using mixed variable optimization

Disclosed herein are representative embodiments of methods, apparatus, and systems for performing radiography analysis. For example, certain embodiments perform radiographic analysis using mixed variable computation techniques. One exemplary system comprises a radiation source, a two-dimensional detector for detecting radiation transmitted through a object between the radiation source and detector, and a computer. In this embodiment, the computer is configured to input the radiographic image data from the two-dimensional detector and to determine one or more materials that form the object by using an iterative analysis technique that selects the one or more materials from hierarchically arranged solution spaces of discrete material possibilities and selects the layer interfaces from the optimization of the continuous interface data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TriBITS (Tribal Build, Integrate, and Test System)

TriBITS is a configuration, build, test, and reporting system that uses the Kitware open-source CMake/CTest/CDash system. TriBITS contains a number of custom CMake/CTest scripts and python scripts that extend the functionality of the out-of-the-box CMake/CTest/CDash system.

Source record↗

Data movement engine

A memory system of a data processing system includes one or more storage devices and a data rearrangement engine for moving data between memory regions of the plurality of memory regions. The data rearrangement engine is configured to rearrange data stored at non-contiguous addresses in a source memory region into contiguous address in a destination region responsive to a rearrangement specified by a host processing unit of the data processing system. A description of the rearranged data is maintained in a metadata memory region. Rearranged data may be accessed by one or more host processing units. Write-back of data from the destination to the source region may be reduced by use of Bloom filter or the like.

Beard, Jonathan Curtis↗

Low Energy Muon Beam Diagnostics: Scintillating Fiber Profile Monitor

The MeV Test Area (MTA) houses the 400 MeV H- Beam at the end of the Linac and a secondary beamline of muons and pions created from hitting a Tungsten target. The MTA is in the Irradiation Test Area (ITA), where experiments involve studying the effects of radiation on materials in the MTA beam. There is a need for a retractable detector to monitor the secondary beam’s intensity and coarse profile. The SFPM was chosen when considering factors like ability to measure low rates and handle high intensities. The plan was to test different scintillating fibers & Silicon Photomultiplier (SiPM) models to figure out which combination gives the best signals, and gain familiarity with the detector assembly, operation, and data acquisition software before using with final detectors in beamline. The SiPM circuit has been tested with a LED pulser successfully. The immediate steps that follow will be to set the SiPM up on the monitor with three different types of optical fibers, use the Caen software to configure the best mode of data acquisition, and proceed with an offline source test using Strontium-90. Once the most efficient measurement method is clear, they will be ready for use in the beamline.

Leith, Justin↗

Control conditioning

A system includes control circuitry configured to control an output signal. The control circuitry and/or various other sources of undesirable signal components may corrupt the control signal used by the control circuitry to correct the output signal. Conditioning circuitry may effect current-domain repair on the control circuitry by providing feedback-based conditioning actuation, including comparator overdrive, to the control circuitry.

Avestruz, Al-Thaddeus↗

The 'Schwarzschild-Kerr' Equilibrium Configurations

We discuss the possibility of equilibrium between a Schwarzschild black hole possessing zero intrinsic angular momentum and a hyperextreme Kerr source. The balance occurs due to frame-dragging exerted by the latter source on the black-hole constituent, thus giving rise to a non-zero horizon's angular velocity parallel to the angular momentum of the Kerr object.

79 ASTRONOMY AND ASTROPHYSICS↗

Do the compact radio sources in NGC 253 and M82 fade over time?

The nearby starburst galaxy NGC 253 has been observed at a third epoch at 6 cm, and a second epoch at 3.6 cm, using the highest resolution configuration of the Very Large Array (VLA). Over a total time span of 4 yr between 1987 and 1991, no new compact radio sources have appeared. The flux density limit ranges from 3 mJy (3 times the power of Cas A) for most of the main body of the source to approximately 0.3 mJy off the diffuse source surrounding the nucleus. Furthermore, there is no evidence for significant source fading over 4 yr, in contrast to the result reported by Kronberg & Sramek (1985) for M82. More recent data suggest that, except for the strongest source in that galaxy, the compact radio sources in M82 may not be fading after all. If this suggestion proves correct, supernova rates of 0.2-0.3/yr in M82, estimated based on the assumed source fading, are incorrect. More accurate limits on source fading indicate that the current rate of production of radio supernovae in M82 is no greater than 0.1/yr, while that in NGC 253 is no greater than 0.25/yr.

Ulvestad, James S.↗

A new large area lanthanum hexaboride plasma source

A new 18x18 cm{sup 2} active area lanthanum hexaboride (LaB{sub 6}) plasma source for use in a dc discharge has been developed at UCLA. The cathode consists of four tiled LaB{sub 6} pieces indirectly heated to electron emission (1750 deg. C) by a graphite heater. A molybdenum mesh anode 33 cm in front of the LaB{sub 6} accelerates the electrons, ionizing a fill gas to create a 20x20 cm{sup 2} nearly square plasma. The source is run in pulsed operation with the anode biased up to +400 V dc with respect to the cathode for up to 100 ms at a 1 Hz repetition rate. Both the cathode and anode ''float'' electrically with respect to the chamber walls. The source is placed in a toroidal chamber 2 m wide and 3 m tall with a major radius of 5 m. Toroidal and vertical magnetic fields confine the current-free plasma which follows the field in a helix. The plasma starts on the bottom of the machine and spirals around it up to four times (120 m) and can be configured to terminate either on the top wall or on the neutral gas itself. The source typically operates with a discharge current up to 250 A in helium making plasmas with T{sub e}<30 eV, T{sub i}<16 eV, and n{sub e}<3x10{sup 13} cm{sup -3} in a background field of 100 G<B{sub o}<320 G, giving a magnetized plasma with 0.1<{beta}<1.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An Experimental Investigation of the 30P30N Multi-Element High-Lift Airfoil

High-lift devices often generate an unsteady flow field producing both broadband and tonal noise which radiates from the aircraft. In particular, the leading edge slat is often a dominant contributor to the noise signature. An experimental study of a simplified unswept high-lift configuration, the 30P30N, has been conducted to understand and identify the various flow-induced noise sources around the slat. Closed-wall wind tunnel tests are performed in the Florida State Aeroacoustic Tunnel (FSAT) to characterize the slat cove flow field using a combination of surface and off-body measurements. Mean surface pressures compare well with numerical predictions for the free-air configuration. Consistent with previous measurements and computations for 2D high-lift configurations, the frequency spectra of unsteady surface pressures on the slat surface display several narrowband peaks that decrease in strength as the angle of attack is increased. At positive angles of attack, there are four prominent peaks. The three higher frequency peaks correspond, approximately, to a harmonic sequence related to a feedback resonance involving unstable disturbances in the slat cove shear layer. The Strouhal numbers associated with these three peaks are nearly insensitive to the range of flow speeds (41-58 m/s) and the angles of attack tested (3-8.5 degrees). The first narrow-band peak has an order of magnitude lower frequency than the remaining peaks and displays noticeable sensitivity to the angle of attack. Stereoscopic particle image velocimetry (SPIV) measurements provide supplementary information about the shear layer characteristics and turbulence statistics that may be used for validating numerical simulations.

Pascioni, Kyle A.↗