Search NASA⌕ Search

SEARCH · Search NASA

Results for “Accelerators, Instrumentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

Resonant excitation of betatron oscillations

Resonant excitation of betatron oscillations is a proposed mechanism for creating large amplitude, sinusoidal electron oscillations by overlaying a standard magnetic undulator and the radial electric fields of an ion channel to effectively create a very high strength undulator. By satisfying a resonance condition between the undulator and betatron periods, large transverse wiggling amplitudes are possible at short periods of oscillation. This skirts the existing limitations of magnetic undulators whose effective strength is constrained by the limits on high peak field values in a short (~cm) period. Additionally, such motion can be achieved with on axis beam injection and greater operational amplitude and polarization tunability than offered in other incarnations of the plasma wiggler. This technique provides a path to applications that demand high K, tunable, bright x-ray or gamma ray radiation such as high flux polarized positron production and a practical realization of the ion channel laser.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Beam debunching due to ISR-induced energy diffusion

One of the options for increasing longitudinal coherency of X-ray free electron lasers (XFELs) is seeding with a microbunched electron beam. Several schemes leading to significant amplitude of the beam bunching at X-ray wavelengths were recently proposed. All these schemes rely on beam optics having several magnetic dipoles. While the beam passes through a dipole, its energy spread increases due to quantum effects of synchrotron radiation. As a result, the bunching factor at small wavelengths reduces since electrons having different energies follow different trajectories in the bend. We rigorously calculate the reduction in the bunching factor due to incoherent synchrotron the radiation while the beam travels in an arbitrary beamline. Lastly, we apply general results to estimate reduction of harmonic current in common schemes proposed for XFEL seeding.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dynamics of modulated beams in spectral domain

General formalism for describing dynamics of modulated beams along linear beamlines is developed. We describe modulated beams with spectral distribution function which represents Fourier transform of the conventional beam distribution function in the 6-dimensional phase space. The introduced spectral distribution function is localized in some region of the spectral domain for nearly monochromatic modulations. It can be characterized with a small number of typical parameters such as the lowest order moments of the spectral distribution. We study evolution of the modulated beams in linear beamlines and find that characteristic spectral parameters transform linearly. The developed approach significantly simplifies analysis of various schemes proposed for seeding X-ray free electron lasers. We use this approach to study several recently proposed schemes and find the bandwidth of the output bunching in each case.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimization of LANSCE proton beam performance for isotope production

The LANSCE Isotope Production Facility (IPF) utilizes a 100-MeV proton beam with average power of 23 kW for isotope production in the fields of medicine, nuclear physics, national security, environmental science and industry. Typical tolerable fractional beam loss in the 100-MeV beamline is 4 x 10 -3 . Experimental beam study was made to minimize the beam losses. Adjustments to the ion source’s extraction voltage resulted in the removal of tails in phase space. Beam based steering in beamlines led to the reduction of beam emittance growth. Readjustment of the 100-MeV quadrupole transport resulted in the elimination of excessive beam envelope oscillations and removed significant parts of the beam halo at the target. Careful beam matching in the drift tube linac (DTL) provided high beam capture (75%) in the DTL. Finally, after improvements, beam losses in the 100-MeV beamline were reduced by an order of magnitude and reached the fractional level of 5 x 10 -4 .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calculations versus measurements for residual dose rates from SNS spent structures

Here, residual dose rate measurements were conducted on target vessel #13 and proton beam window #5 after extraction from their service locations. These measurements are used to verify calculation methods of radionuclide inventory assessment that are typically performed for nuclear waste characterization and transportation of these structures. Neutronics analyses for predicting residual dose rates are carried out using the transport code MCNPX and the transmutation code CINDER90. For transport analyses a complex and rigorous geometry model of the structures and their surroundings are applied. The neutronics analyses are carried out using the Bertini and CEM high energy physics models for simulating particles interactions above the table-based cross section range. Finally, obtained calculational results are analyzed and compared to the measured dose rates and overall show good agreement within 25%, which shows applicability of the methods used in analyses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Innovative approaches to neutron beam optimization: A case study of FP14 at LANSCE

This paper describes an experimental method to acquire high resolution energy- and spatially- resolved neutron beam spots using the time-gated neutron imaging system with Teledyne Pi-MAX4 camera. These experimental data offer a unique opportunity for benchmarking beam spot simulations. High-quality simulations depend significantly on a high-fidelity geometry model, which can be challenging for legacy facilities. We informed our MCNPX geometry model by latest metrology survey employing Leica laser tracker ATS600. It gave us a high fidelity description of our facility geometry. Such a robust integration of novel tools and methods yields a previously unattainable level of accuracy in both predicting and capturing neutron beam spots, marking a notable advancement over traditional methods reliant on static image plates. Here, to demonstrate the practical application of these tools, we are showing a non-uniform beam spot challenge at our Flight Path 14 (FP14) at the Los Alamos Neutron Science Center (LANSCE). Our precise MCNPX prediction of beam spot shifting as function of neutron energy was confirmed by experimental beam spot measured with extremely high level of detail. Results of this research demonstrate a significant leap in neutron beam optimization at LANSCE and set a new benchmark in beam spot characterization. The advanced methods presented here have potential for adoption at similar research facilities worldwide, aiming at substantial improvement in neutron beam delivery for experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A control system of a negative hydrogen ion sources by using an EPICS-based proportional-integral-derivative

We have developed an EPICS-based control system for a multicusp negative ion source based on a VME IOC software, a sequencer controlling a closed proportional integral (PI) loop, and an interlock. The PI loop was tuned by a step input voltage, and tuning gains of the proportion and integral have been determined. The PI logics, developed by using standard proportional-integral-derivative records, can control the arc current within {+-}1% of a given set value.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CERN and the Hunt for Elementary Particles and Forces

CERN is the European Laboratory for Particle Physics, the world's largest particle physics research centre. Founded in 1954, the Laboratory was one of Europe's first joint ventures and has become a premier example of international collaboration. CERN's subject of study is pure science and is concentrated on exploring the Universe's most fundamental questions, such as What is it made of? and How did it come to be the way it is? The Laboratory's tools, the particle accelerators and particle detectors, are amongst the world's largest and most complex scientific instruments. The Laboratory's primary aims will be presented and a look at past achievements and present endeavours, particularly the Large Hadron Collider (LHC), will be reviewed. A brief look into the future will also be given.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Z{sub eff} profile measurement system with an optimized Czerny-Turner visible spectrometer in large helical device

Z{sub eff} measurement system using a visible spectrometer has been newly designed and constructed instead of an old interference filter system to eliminate line emissions from the signal and to measure the Z{sub eff} value in low-density plasmas. The system consists of the Czerny-Turner-type spectrometer with a charge-coupled device camera and 44 optical fibers vertical array. The spectrometer is equipped with an additional toroidal mirror for further reduction in the astigmatism in addition to a flat and two spherical mirrors and three gratings (110, 120, and 1200 grooves/mm) with 30 cm focal length. The images from 44 optical fibers can be detected without astigmatism in a wavelength range of 200-900 nm. Combination of the optical fiber (core diameter: 100 {mu}m) with the lens (focal length: 30 mm) provides spatial resolution of 30 mm at the plasma center. Results clearly indicate a very good focus image of the fiber and suggest the absence of the cross-talk between adjacent fiber images. Absolute intensity calibration has been done using a standard tungsten lamp to analyze the Z{sub eff} value. The bremsstrahlung profile and resultant Z{sub eff} profile have been obtained after Abel inversion of the signals observed in large helical device plasmas with elliptical poloidal cross section.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A method to measure the frequencies of individual half cells in a dumbbell cavity

Dumbbell fabrication is a midprocess for manufacturing an elliptical superconducting rf cavity. In order to understand how a welding shrinkage affects a dumbbell's frequencies and length, we need to measure the exact frequencies of each individual half cell of a dumbbell. To improve such a calculation precision and to simplify the calculation formulae, based on a two-coupled oscillator model and a cavity perturbation theory, a new formula to calculate the individual half-cell frequencies of a dumbbell or the individual cavity frequencies of a two-cavity coupling system has been developed, and its performance has been confirmed by using a dumbbell simulation. This formula can be applied to any kind of rf cavities with electric, magnetic, or electromagnetic coupling, if a coupling hole between two coupling cavities is small compared to the wavelength. Compared to other calculation formulae, this formula simplifies the calculation process of the individual resonator frequencies of a coupling system considerably, and it can also improve the calculation precision than that of a normal calculation method. Another advantage of this new method is that we do not need to consider a coupling factor between two resonators during a testing for an individual resonator frequency of an oscillator. The developed formula has been successfully used to tune the PEFP dumbbells.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spin Filtering Studies at COSY and AD

The high physics potential of experiments with stored high-energy polarized antiprotons led to the proposal of PAX (Polarized Antiproton eXperiment) for the High Energy Storage Ring (HESR) of the FAIR at GSI (Darmstadt/Germany). It is proposed to polarize a stored antiproton beam by means of spin filtering with a polarized H (D) gas target. The feasibility of spin filtering has been demonstrated in the FILTEX experiment. The current interpretation foresees a self-cancellation of the electron contribution to the filtering process and only the hadronic contribution is effective. Several experimental studies with protons (at COSY/Juelich) as well as antiprotons (at AD/CERN) will be carried out to test the principle and measure p-barp-vector and p-bard-vector cross sections. A polarized internal gas target (PIT) with surrounding Silicon detectors immersed into a low-beta section has to be set up.

43 PARTICLE ACCELERATORS↗

COMPARISON OF THEORY AND MEASUREMENTS OF A TWO-STAGE LIGHT-GAS GUN

A comparison of techniques for obtaining projectile velocity history on a two-stage launcher and discuss gun code accuracy vis-a-vis pressure gauges and the new photonic Doppler velocimetry (PDV) technique is presented. The PDV technique itself is described in a companion paper. The PDV records were differentiated to compute acceleration and, hence, base pressure. Two acceleration episodes are revealed in the data. Base pressure values were compared with measurements from stationary pressure gauges and with predictions of a standard two-stage gun code. The agreement with the pressure gages was satisfactory. Code predictions did not account for the two acceleration stages. However, for the main acceleration episode, the predicted base pressure is in good agreement with the smoothed pressure computed from the PDV record. Both the gauge records and PDV contain short-time pressure spikes which are apparently real. Therefore, use of computed base pressure for projectile design may lead to failures if the projectile is vulnerable to pressure spikes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Computation of Ion Charge State Distributions After Inner-Shell Ionization In Ne, Ar And Kr Atoms Using Monte Carlo Simulation

Atomic reorganization starts by filling the initially inner-shell vacancy by a radiative transition (x-ray) or by a non-radiative transition (Auger and Coster-Kronig processes). New vacancies created during this atomic reorganization may in turn be filled by further radiative and non-radiative transitions until all vacancies reach the outermost occupied shells. The production of inner-shell vacancy in an atom and the de-excitation decays through radiative and non-radiative transitions may result in a change of the atomic potential; this change leads to the emission of an additional electron in the continuum (electron shake-off processes). In the present work, the ion charge state distributions (CSD) and mean atomic charge ions produced from inner-shell vacancy de-excitation decay are calculated for neutral Ne, Ar and Kr atoms. The calculations are carried out using Monte Carlo (MC) technique to simulate the cascade development after primary vacancy production. The radiative and non-radiative transitions for each vacancy are calculated in the simulation. In addition, the change of transition energies and transition rates due to multi vacancies produced in the atomic configurations through the cascade development are considered in the present work. It is found that considering the electron shake--off process and closing of non-allowed non-radiative channels improves the results of both charge state distributions (CSD) and average charge state. To check the validity of the present calculations, the results obtained are compared with available theoretical and experimental data. The present results are found to agree well with the available theoretical and experimental values.

36 MATERIALS SCIENCE↗

Electron Reconstruction and Identification with the ATLAS Detector

Several Standard Model processes contain electrons in the final state. Also, many signatures expected from physics beyond the Standard Model include one or more electrons. This paper describes the electron reconstruction along with some of the identification criteria used in the ATLAS detector. The expected performance at the start-up of the experiment are also presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Progress on the Development of XRF Imaging and Analysis at the Siam Photon Laboratory

XRF imaging and analysis at the Siam Photon Laboratory have been recently developed for supporting various applications in x-ray micro analysis. An experimental setup for white beam x-ray fluorescent imaging has been installed at the beamline BL2 for elemental and quantitative analyses. A white micro beam of 163x170 {mu}m{sup 2}(FWHM) measured by wire scanning has been delivered to samples using a polycapillary x-ray half-lens. The fluorescent emissions of characteristic x-rays (1 keV and above) are detected by a Si-PIN detector. XRF imaging of Ni grids on supporting glass and XRF analysis on a trace-element standard were conducted for testing the apparatus. The test results on these samples as well as the necessary software developed for elemental identification and imaging are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Medipix3 array high performance read-out board for synchrotron research

The Medipix3 ASIC is one of the most advanced chip that is presently available to build photon counting area detectors. The capabilities of the chip include adjacent pixels charge summing circuitry to sort out the distortion due to charge sharing, simultaneous counting and read-out that enables frames to be acquired without dead time, the colour mode of operation that enables up to eight energy bands to be acquired. In order to fully exploit the capabilities of the Medipix3 chip in synchrotron research, a high performance electronic board capable of driving large arrays of chips is necessary. We propose a parallel read-out board of Medipix3 chip arrays with a scalable architecture that allows driving the Medipix3 chip in all of its modes of operation. The board functions include the control of the chip arrays, data formatting and data compression, the management of the communications with the data storage devices, and operation in various trigger modes. In addition to this the board will have some 'intelligence' embedded. This will add some very important features to the final detector such as pattern recognition, capability of variable frame duration as a function of the photon flux, feedback to other equipment and real time calculations of data relevant to experiments such as the autocorrelation function.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗