Search NASA⌕ Search

SEARCH · Search NASA

Results for “Adaptive Optics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

Sky-Scanning Sun-Tracking Airborne Radiometer (3STAR): Instrument Design, Flight Testing, and Tracking Performance

The Sky-Scanning, Sun-Tracking Airborne Radiometer (3STAR) adapts commercial radiometer technology developed for the ocean color research community to airborne measurement of spectrally resolved solar irradiance and sky radiance. These atmospheric observations are used to derive aerosol optical depth (AOD), supporting localized AOD inputs for atmospheric correction of satellite and airborne data over terrestrial and aquatic (including optically dark) targets. The ability to regionally “tune” atmospheric correction schemes with relevant spatial AOD supports constraining atmospheric correction of remote sensing reflectance. Very wide dynamic range has been achieved for multi-channel band-pass-filter-radiometers originally designed for deployment into the water column. By actively tracking and directly pointing to the Sun, the light attenuation by aerosol particles in the atmospheric column can be quantified. These measurements improve knowledge of atmospheric constituents and the atmospheric corrections required to improve remote sensing capabilities for interpreting reflectance measurements from the Earth surface. 3STAR incorporates a custom Sun-tracking/sky-scanning pointing head, a Sun-tracking camera, and a commercially available, cylindrical, 19-channel radiometer tube assembly. An accurate and responsive mount and tracking system has been developed and certified to NASA and Naval Air Systems Command (NAVAIR) airworthiness standards for deployment into the aircraft slipstream. Ground and flight testing indicate typical tracking errors of less than 0.1 degrees, well within the field of view of the radiometer as required to minimize measurement uncertainty from alignment error. Preliminary AOD measurements compare to within 0.013 with 15 measurements from an Aerosol Robotic Network (AERONET) Cimel instrument at 500 nm wavelength and low solar angle.

Atmosphere↗

Adaptive Detector Positioning for a Room PET System

Investigating human brain function in response to environmental stimuli requires freely moving humans without attached instrumentation. The RoomPET concept provides a feasible solution for human brain imaging. A RoomPET system is a room that contains an optical head tracking system and PET detectors that move to keep the head in the PET detector field-of-view. As a proof of principle, a small box-size prototype was built to demonstrate feasibility of RoomPET with gantry mechanics, tracking capabilities, and control systems.

Byrd, Brook↗

The x-ray light valve: A potentially low-cost, digital radiographic imaging system-concept and implementation considerations

New x-ray radiographic systems based on large-area flat-panel technology have revolutionized our capability to produce digital x-ray images. However, these imagers are extraordinarily expensive compared to the systems they are replacing. Hence, there is a need for a low-cost digital imaging system for general applications in radiology. A novel potentially low-cost radiographic imaging system based on established technologies is proposed--the X-Ray Light Valve (XLV). This is a potentially high-quality digital x-ray detector made of a photoconducting layer and a liquid-crystal cell, physically coupled in a sandwich structure. Upon exposure to x rays, charge is collected on the surface of the photoconductor. This causes a change in the optical properties of the liquid-crystal cell and a visible image is generated. Subsequently, it is digitized by a scanned optical imager. The image formation is based on controlled modulation of light from an external source. The operation and practical implementation of the XLV system are described. The potential performance of the complete system and issues related to sensitivity, spatial resolution, noise, and speed are discussed. The feasibility of clinical use of an XLV device based on amorphous selenium (a-Se) as the photoconductor and a reflective electrically controlled birefringence cell is analyzed. The results of our analysis indicate that the XLV can potentially be adapted to a wide variety of radiographic tasks.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Iterative procedure for in-situ EUV optical testing with an incoherent source

We propose an iterative method for in-situ optical testing under partially coherent illumination that relies on the rapid computation of aerial images. In this method a known pattern is imaged with the test optic at several planes through focus. A model is created that iterates through possible aberration maps until the through-focus series of aerial images matches the experimental result. The computation time of calculating the through-focus series is significantly reduced by a-SOCS, an adapted form of the Sum Of Coherent Systems (SOCS) decomposition. In this method, the Hopkins formulation is described by an operator S which maps the space of pupil aberrations to the space of aerial images. This operator is well approximated by a truncated sum of its spectral components.

36 MATERIALS SCIENCE↗

Editorial overview: Unlocking the secrets of nongenetic plasticity, one cell at a time

Cellular noise, the non-genetic variability observed among isogenic cells, arises from factors such as growth conditions, aging, and stochastic gene expression, influencing cell stress-response, metabolism, morphology, and size. Here, such plasticity, while critical for adaptation, often goes unnoticed with traditional population-averaging biotechnologies that inevitably mask cell-specific variations and prompting the question, "What else might we be missing". However, recent breakthroughs in optical imaging, microfluidics, and omics, are beginning to uncover the complexity of cellular plasticity. This special is-sue highlights some of these breakthroughs, with key contributions including innovations in multimodal chemical imaging, label-free microscopy, spatial and temporal omics, and droplet-based microfluidics. Collectively, these cutting-edge tools provide unprecedent-ed insights into non-genetic cell-to-cell variability, enhancing our understanding of cellu-lar plasticity and its implications for health, energy, and ecology.

59 BASIC BIOLOGICAL SCIENCES↗

Laser speckle-imaging of blood microcirculation in the brain cortex of laboratory rats in stress

The results of experimental approbation of the method of laser full-field speckle-imaging for monitoring the changes in blood microcirculation state of the brain cortex of laboratory rats under the conditions of developing stroke and administration of vasodilating and vasoconstrictive agents are presented. The studies aimed at the choice of the optimal conditions of speckle-image formation and recording were performed and the software implementing an adaptive algorithm for processing the data of measurements was created. The transfer of laser radiation to the probed region of the biotissue was implemented by means of a silica-polymer optical fibre. The problems and prospects of speckle-imaging of cerebral microcirculation of blood in laboratory and clinical conditions are discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A broadband RF continuously variable time delay device

A method for implementation of continuously variable time delay of broadband RF signals is described. The method uses Bragg Cell and optical heterodyne technology. The signal to be delayed is applied to the Bragg Cell acoustic transducer, and the delay time is the acoustic transit time from this transducer to the incident light beam. By translating the light beam, the delay is varied. Expressions describing the Bragg Cell diffraction, lens Fourier transformation, and the optical heterodyne processes are developed. Specifications for the variable delay including bandwidth, range of delay, and insertion loss are provided. Applications include radar signal processing, spread spectrum intercept, radar ECM, and adaptive array antenna processing.

Freyre, F. W.↗

Spacecraft contamination investigation by direct simulation Monte Carlo - Contamination on UARS/HALOE

A three-dimensional version of the direct simulation Monte Carlo method is adapted to study the contamination environment surrounding a highly detailed model of the Upper Atmosphere Research Satellite, with the ultimate goal of estimating the cumulative level of molecular deposits on critical optical surfaces of the Halogen Occultation Experiment. Emphasis is placed on describing the development of preprocessing codes that simplify the incorporation of geometry and outgassing data into the main run code. A novel use of parallel processing software allows use of multiple processors to solve different regions of the overall flowfield. Initial results relating to contaminant cloud structure, cloud composition, and statistics of simulated molecules impinging on the Halogen Occultation telescope's aperture plane are presented, along with data related to code performance.

Rault, Didier F. G.↗

Modeling of an Adjustable Beam Solid State Light Project

This proposal is for the development of a computational model of a prototype variable beam light source using optical modeling software, Zemax Optics Studio. The variable beam light source would be designed to generate flood, spot, and directional beam patterns, while maintaining the same average power usage. The optical model would demonstrate the possibility of such a light source and its ability to address several issues: commonality of design, human task variability, and light source design process improvements. An adaptive lighting solution that utilizes the same electronics footprint and power constraints while addressing variability of lighting needed for the range of exploration tasks can save costs and allow for the development of common avionics for lighting controls.

Clark, Toni↗

A study of topologies and protocols for fiber optic local area network

The emergence of new applications requiring high data traffic necessitates the development of high speed local area networks. Optical fiber is selected as the transmission medium due to its inherent advantages over other possible media and the dual optical bus architecture is shown to be the most suitable topology. Asynchronous access protocols, including token, random, hybrid random/token, and virtual token schemes, are developed and analyzed. Exact expressions for insertion delay and utilization at light and heavy load are derived, and intermediate load behavior is investigated by simulation. A new tokenless adaptive scheme whose control depends only on the detection of activity on the channel is shown to outperform round-robin schemes under uneven loads and multipacket traffic and to perform optimally at light load. An approximate solution to the queueing delay for an oscillating polling scheme under chaining is obtained and results are compared with simulation. Solutions to the problem of building systems with a large number of stations are presented, including maximization of the number of optical couplers, and the use of passive star/bus topologies, bridges and gateways.

Yeh, C.↗

The need for application-based adaptation of deformable image registration

Purpose: To utilize a deformable phantom to objectively evaluate the accuracy of 11 different deformable image registration (DIR) algorithms. Methods: The phantom represents an axial plane of the pelvic anatomy. Urethane plastic serves as the bony anatomy and urethane rubber with three levels of Hounsfield units (HU) is used to represent fat and organs, including the prostate. A plastic insert is placed into the phantom to simulate bladder filling. Nonradiopaque markers reside on the phantom surface. Optical camera images of these markers are used to measure the positions and determine the deformation from the bladder insert. Eleven different DIR algorithms are applied to the full and empty-bladder computed tomography images of the phantom (fixed and moving volumes, respectively) to calculate the deformation. The algorithms include those from MIM Software (MIM) and Velocity Medical Solutions (VEL) and nine different implementations from the deformable image registration and adaptive radiotherapy toolbox for Matlab. These algorithms warp one image to make it similar to another, but must utilize a method for regularization to avoid physically unrealistic deformation scenarios. The mean absolute difference (MAD) between the HUs at the marker locations on one image and the calculated location on the other serves as a metric to evaluate the balance between image similarity and regularization. To demonstrate the effect of regularization on registration accuracy, an additional beta version of MIM was created with a variable smoothness factor that controls the emphasis of the algorithm on regularization. The distance to agreement between the measured and calculated marker deformations is used to compare the overall spatial accuracy of the DIR algorithms. This overall spatial accuracy is also utilized to evaluate the phantom geometry and the ability of the phantom soft-tissue heterogeneity to represent patient data. To evaluate the ability of the DIR algorithms to accurately transfer anatomical contours, the rectum is delineated on both the fixed and moving images. A Dice similarity coefficient is then calculated between the contour on the fixed image and that transferred, via the calculated deformation, from the moving to the fixed image. Results: The phantom possesses sufficient soft-tissue heterogeneity to act as a proxy for patient data. Large discrepancies appear between the algorithms and the measured ground-truth deformation. VEL yields the smallest mean spatial error and a Dice coefficient of 0.90. MIM produces the lowest MAD value and the highest Dice coefficient of 0.96, but creates the largest spatial errors. Increasing the MIM smoothness factor above the default value improves the overall spatial accuracy, but the factor associated with the lowest mean error decreases the Dice coefficient to 0.85. Conclusions: Different applications of DIR require disparate balances between image similarity and regularization. A DIR algorithm that is optimized only for its ability to transfer anatomical contours will yield large deformation errors in homogeneous regions, which is problematic for dose mapping. For this reason, these algorithms must be tested for their overall spatial accuracy. The developed phantom is an objective tool for this purpose.

60 APPLIED LIFE SCIENCES↗

Controlling optical-cavity locking using reinforcement learning

Abstract This study applies an effective methodology based on Reinforcement Learning to a control system. Using the Pound–Drever–Hall locking scheme, we match the wavelength of a controlled laser to the length of a Fabry-Pérot cavity such that the cavity length is an exact integer multiple of the laser wavelength. Typically, long-term drift of the cavity length and laser wavelength exceeds the dynamic range of this control if only the laser’s piezoelectric transducer is actuated, so the same error signal also controls the temperature of the laser crystal. In this work, we instead implement this feedback control grounded on Q-Learning. Our system learns in real-time, eschewing reliance on historical data, and exhibits adaptability to system variations post-training. This adaptive quality ensures continuous updates to the learning agent. This innovative approach maintains lock for eight days on average.

47 OTHER INSTRUMENTATION↗

Implications of theoretical analysis to explore the functional core dimension in one-rod core microstructured optical fibers

A new development in optical fiber technology that has attracted interest for multitude of novel and potential applications is an all-in-silica microstructured optical fibre (MOF) with one-rod core. We aim to estimate the functional core dimension for one-rod core triangular MOF (T-MOF) from its geometrical characteristics by using an alternative analytical field model. Moreover, to scrutinize the validity of the choice of effective core dimension (by adapting V-parameter, i.e., the normalized frequency) for T-MOF, we have explored the rudimentary propagation characteristics of the T-MOF in single mode guidance realm. We made comparisons with those which are based on the experimental and numerical studies. Relative errors are also reported.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Cape Hatteras Ecological Conservation: Delineating Shoreline and Mapping Change Along the Cape Hatteras National Seashore for Coastline Management and Transportation Corridor Adaptation Strategies

The National Park Service at Cape Hatteras National Seashore works to protect North Carolina’s Outer Banks where frequent storms bring heavy winds and flooding, leading to overwash events on the main highway, North Carolina Highway 12. Shorelines are susceptible to erosion directly affecting transportation and housing infrastructures. Storm events can disrupt transportation on NC-12 and ferry service from Ocracoke Island to Hatteras Island, leaving inhabitants stranded on Ocracoke Island for indefinite amounts of time. The National Park Service’s current decision-making practices involve mitigating infrastructure damage by enlisting the help of North Carolina’s Department of Transportation and finding ways to relocate this infrastructure, as well as dredging and sediment placement that support beach nourishment efforts. Our NASA DEVELOP team partnered with the National Park Service to explore the use of optical data to delineate shoreline and map coastline change from 2014 to 2024. We used Earth observations collected by Landsat 8 Operational Land Imager, Landsat 9 Operational Land Imager-2, and Sentinel-2 MultiSpectral instrument to support decision-making related to prioritizing strategic planning for transportation corridor adaptations including potential relocation of infrastructure, and beach nourishment efforts. We derived coastline maps by consolidating images from each year to create composite images for winter and summer coastline seasonal oscillation patterns. The results highlight shoreline loss over the ~10-year study period, and the difference in shoreline inundation in the winter and summer seasons. These observations create a better understanding of successful mitigation efforts and allow the National Park Service to continue to focus on plans for infrastructure updates.

Ella Haugen↗

Dosimetric performance and array assessment of plastic scintillation detectors for stereotactic radiosurgery quality assurance

Purpose: To compare the performance of plastic scintillation detectors (PSD) for quality assurance (QA) in stereotactic radiosurgery conditions to a microion-chamber (IC), Gafchromic EBT2 films, 60 008 shielded photon diode (SD) and unshielded diodes (UD), and assess a new 2D crosshair array prototype adapted to small field dosimetry. Methods: The PSD consists of a 1 mm diameter by 1 mm long scintillating fiber (BCF-60, Saint-Gobain, Inc.) coupled to a polymethyl-methacrylate optical fiber (Eska premier, Mitsubishi Rayon Co., Ltd., Tokyo, Japan). Output factors (S{sub c,p}) for apertures used in radiosurgery ranging from 4 to 40 mm in diameter have been measured. The PSD crosshair array (PSDCA) is a water equivalent device made up of 49 PSDs contained in a 1.63 cm radius area. Dose profiles measurements were taken for radiosurgery fields using the PSDCA and were compared to other dosimeters. Moreover, a typical stereotactic radiosurgery treatment using four noncoplanar arcs was delivered on a spherical phantom in which UD, IC, or PSD was placed. Using the Xknife planning system (Integra Radionics Burlington, MA), 15 Gy was prescribed at the isocenter, where each detector was positioned. Results: Output Factors measured by the PSD have a mean difference of 1.3% with Gafchromic EBT2 when normalized to a 10 x 10 cm{sup 2} field, and 1.0% when compared with UD measurements normalized to the 35 mm diameter cone. Dose profiles taken with the PSD crosshair array agreed with other single detectors dose profiles in spite of the presence of the 49 PSDs. Gamma values comparing 1D dose profiles obtained with PSD crosshair array with Gafchromic EBT2 and UD measured profiles shows 98.3% and 100.0%, respectively, of detector passing the gamma acceptance criteria of 0.3 mm and 2%. The dose measured by the PSD for a complete stereotactic radiosurgery treatment is comparable to the planned dose corrected for its SD-based S{sub c,p} within 1.4% and 0.7% for 5 and 35 mm diameter cone, respectively. Furthermore, volume averaging of the IC can be observed for the 5 mm aperture where it differs by as much as 9.1% compared to the PSD measurement. The angular dependency of the UD is also observed, unveiled by an under-response around 2.5% of both 5 and 35 mm apertures. Conclusions: Output Factors and dose profiles measurements performed, respectively, with the PSD and the PSDCA were in agreement with those obtained with the UD and EBT2 films. For stereotactic radiosurgery treatment verification, the PSD gives accurate results compared to the planning system and the IC once the latter is corrected to compensate for the averaging effect of the IC. The PSD provides precise results when used as a single detector or in a dense array, resulting in a great potential for stereotactic radiosurgery QA measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Assurance Technology Challenges of Advanced Space Systems

The initiative to explore space and extend a human presence across our solar system to revisit the moon and Mars post enormous technological challenges to the nation's space agency and aerospace industry. Key areas of technology development needs to enable the endeavor include advanced materials, structures and mechanisms; micro/nano sensors and detectors; power generation, storage and management; advanced thermal and cryogenic control; guidance, navigation and control; command and data handling; advanced propulsion; advanced communication; on-board processing; advanced information technology systems; modular and reconfigurable systems; precision formation flying; solar sails; distributed observing systems; space robotics; and etc. Quality assurance concerns such as functional performance, structural integrity, radiation tolerance, health monitoring, diagnosis, maintenance, calibration, and initialization can affect the performance of systems and subsystems. It is thus imperative to employ innovative nondestructive evaluation methodologies to ensure quality and integrity of advanced space systems. Advancements in integrated multi-functional sensor systems, autonomous inspection approaches, distributed embedded sensors, roaming inspectors, and shape adaptive sensors are sought. Concepts in computational models for signal processing and data interpretation to establish quantitative characterization and event determination are also of interest. Prospective evaluation technologies include ultrasonics, laser ultrasonics, optics and fiber optics, shearography, video optics and metrology, thermography, electromagnetics, acoustic emission, x-ray, data management, biomimetics, and nano-scale sensing approaches for structural health monitoring.

Chern, E. James↗

Fomalhaut's Debris Disk and Planet: Constraining the Mass of Formalhaut B from Disk Morphology

Following the optical imaging of exoplanet candidate Fomalhaut b (Fom b), we present a numerical model of how Fomalhaut's debris disk is gravitationally shaped by a single interior planet. The model is simple, adaptable to other debris disks, and can be extended to accommodate multiple planets. If Fom b is the dominant perturber of the belt, then to produce the observed disk morphology it must have a mass M(sub pl) < 3M(sub J), an orbital semimajor axis a(sub pl) > 101.5AU, and an orbital eccentricity e(sub pl) = 0.11 - 0.13. These conclusions are independent of Fom b's photometry. To not disrupt the disk, a greater mass for Fom b demands a smaller orbit farther removed from the disk; thus, future astrometric measurement of Fom b's orbit, combined with our model of planet-disk interaction, can be used to determine the mass more precisely. The inner edge of the debris disk at a approximately equals 133AU lies at the periphery of Fom b's chaotic zone, and the mean disk eccentricity of e approximately equals 0.11 is secularly forced by the planet, supporting predictions made prior to the discovery of Fom b. However, previous mass constraints based on disk morphology rely on several oversimplifications. We explain why our constraint is more reliable. It is based on a global model of the disk that is not restricted to the planet's chaotic zone boundary. Moreover, we screen disk parent bodies for dynamical stability over the system age of approximately 100 Myr, and model them separately from their dust grain progeny; the latter's orbits are strongly affected by radiation pressure and their lifetimes are limited to approximately 0.1 Myr by destructive grain-grain collisions. The single planet model predicts that planet and disk orbits be apsidally aligned. Fomalhaut b's nominal space velocity does not bear this out, but the astrometric uncertainties are difficult to quantify. Even if the apsidal misalignment proves real, our calculated upper mass limit of 3 M(sub J) still holds. Parent bodies are evacuated from mean-motion resonances with Fom b; these empty resonances are akin to the Kirkwood gaps opened by Jupiter. The belt contains at least 3M(sub Earth) of solids that are grinding down to dust, their velocity dispersions stirred so strongly by Fom b that collisions are destructive. Such a large mass in solids is consistent with Fom b having formed in situ.

Chiang, E.↗

Continental-Scale Validation of Modis-Based and LEDAPS Landsat ETM + Atmospheric Correction Methods

The potential of Landsat data processing to provide systematic continental scale products has been demonstratedby several projects including the NASA Web-enabled Landsat Data (WELD) project. The recent freeavailability of Landsat data increases the need for robust and efficient atmospheric correction algorithms applicableto large volume Landsat data sets. This paper compares the accuracy of two Landsat atmospheric correctionmethods: a MODIS-based method and the Landsat Ecosystem Disturbance Adaptive ProcessingSystem (LEDAPS) method. Both methods are based on the 6SV radiative transfer code but have different atmosphericcharacterization approaches. The MODIS-based method uses the MODIS Terra derived dynamicaerosol type, aerosol optical thickness, and water vapor to atmospherically correct ETM+ acquisitions ineach coincident orbit. The LEDAPS method uses aerosol characterizations derived independently from eachLandsat acquisition and assumes a fixed continental aerosol type and uses ancillary water vapor. Validationresults are presented comparing ETM+ atmospherically corrected data generated using these two methodswith AERONET corrected ETM+ data for 95 10 km10 km 30 m subsets, a total of nearly 8 million 30 mpixels, located across the conterminous United States. The results indicate that the MODIS-based methodhas better accuracy than the LEDAPS method for the ETM+ red and longer wavelength bands.

Atmospheric correction↗