Search NASA⌕ Search

SEARCH · Search NASA

Results for “Building Demand”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

A bioinspired approach for adaptive solid-solid phase change material coatings with optimized surface features for passive thermal regulation

The necessity to reduce global energy consumption calls for innovative strategies in building thermal management. Passive thermal regulation, particularly through bio-inspired designs, offers a promising avenue by mimicking nature's efficient control of optical properties. This research introduces a novel, climate-responsive coating that integrates optimized bio-inspired surface features with a solid-solid phase change material (SS-PCM) to dynamically manage solar absorptivity without adding additional thickness, enabling both heating and cooling as needed. Drawing on the photonic architectures of the Saharan silver ant and Morpho Didius butterfly, we employed a modeling and multi-objective optimization framework to tailor these surface features. Simulations reveal that surface texture, rather than the intrinsic phase transition of the SS PCM, dominates optical control. Relative to a flat SS PCM coating, optimized isotropic random roughness and broader range features yielded the highest passive heating power increase of about 144 % and 319 % respectively suitable for cold climates. Saharan ant-inspired features enhanced passive cooling for hot climates, achieving a 21.8 % improvement. For moderate climates, Butterfly-wing-inspired surface features provided a balanced enhancement of 19 % for heating and 7 % for cooling. Across all cases, the optimized surface features reduced combined heating and cooling energy demand more effectively than the baseline coating, while preserving material thickness. These findings demonstrate that climate-adaptive, optimized bio-inspired surface features can unlock the full potential of SS PCM coatings, providing a versatile pathway to significant energy savings in buildings and other applications. The methodology establishes a framework for designing next-generation adaptive envelopes that leverage natural photonic principles for high-impact, low-cost thermal regulation.

36 MATERIALS SCIENCE↗

COVID-19 pandemic ramifications on residential Smart homes energy use load profiles

The COVID-19 pandemic has significantly affected people’s behavioral patterns and schedules because of stay-at-home orders and a reduction of social interactions. Therefore, the shape of electrical loads associated with residential buildings has also changed. In this paper, we quantify the changes and perform a detailed analysis on how the load shapes have changed, and we make potential recommendations for utilities to handle peak load and demand response. Our analysis incorporates data from before and after the onset of the COVID-19 pandemic, from an Alabama Power Smart Neighborhood with energy-efficient/smart devices, using around 40 advanced metering infrastructure data points. This paper highlights the energy usage pattern changes between weekdays and weekends pre– and post–COVID-19 pandemic times. The weekend usage patterns look similar pre– and post–COVID-19 pandemic, but weekday patterns show significant changes. We also compare energy use of the Smart Neighborhood with a traditional neighborhood to better understand how energy-efficient/smart devices can provide energy savings, especially because of increased work-from-home situations. HVAC and water heating remain the largest consumers of electricity in residential homes, and our findings indicate an even further increase in energy use by these systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Assessing electrification readiness in U.S. single-family homes based on a nationwide survey of electrical panel capacities

Electrification of residential buildings is a key strategy for increasing the use of renewable energy sources. Central to this transition is understanding the capacity of existing electrical infrastructure—specifically electrical panels—to safely and effectively manage increased electricity demands from electrification technologies. However, comprehensive nationwide data on electrical panel capacities in U.S. single-family homes is currently lacking. To address this gap, we conducted a nationwide survey of single-family homes, collecting detailed data on electrical panel capacities, breaker slot availability, major electric and gas appliances, electrical panel models, and home characteristics such as construction year and floor area. Photographic documentation was used to verify electrical panel data and appliance information. Results show that approximately 60% of surveyed homes have electrical panels rated at ≥200 amperes (A), indicating that a significant portion of the existing housing stock can accommodate additional electric loads. However, 31% of homes possess panels rated at ≤100 A, potentially restricting their ability to adopt new electric appliances without significant upgrades. Panel capacities positively correlate with both home size and construction year, with newer and larger homes generally better suited for electrification. Homes with higher-capacity panels tend to have fewer gas appliances, reflecting a gradual shift toward electric technologies. Conversely, homes with lower-capacity panels frequently rely on multiple gas appliances, highlighting substantial electrification challenges. Additionally, approximately 3% of surveyed homes had potentially hazardous electrical panel models, emphasizing important safety considerations in the residential electrification process. Our findings underscore the need for targeted policies, financial incentives, and infrastructure investments designed specifically to address infrastructural and safety barriers, particularly in older and smaller homes, to support equitable and efficient electrification across the U.S. residential sector.

Gul, Sadia↗

Refueling infrastructure planning in intercity networks considering route choice and travel time delay for mixed fleet of electric and conventional vehicles

The range anxiety has been a major factor that affects the market acceptance of electric vehicles. Even with the recent development of battery technologies, a lack of charging stations and range anxiety are still significant concerns, specifically for intercity trips. This calls for more investments in building charging stations and advancing battery technologies to increase the market share of electric vehicles and improve sustainability. This study suggests a configuration for plug-in electric vehicle charging infrastructure to support long-distance intercity trips of electric vehicles at the network level. A model is proposed to minimize the total system cost including infrastructure investment (building charging stations/spots) and travel time delays (charging time, waiting time in the queue, and detour time to access charging stations). This study fills existing gaps in the literature by capturing realistic patterns of travel demand and considering flow-dependent charging delays at charging stations. Furthermore, the proposed model, which is formulated as a mixed-integer program with nonlinear constraints, solves the optimization problem at the network level. At the network level, impacts of charging station locations on the traffic assignment problem with a mixed fleet of electric and conventional vehicles need to be considered. To this end, a traffic assignment module is integrated with a simulated annealing algorithm. The numerical experiments show a satisfactory application of the model for a full-scale case study (intercity network in Michigan). The solution quality and efficiency of the proposed solution algorithm are evaluated against those of an enumeration approach for a small case study. The results suggest that even for the current market share and charging stations’ setting, a significant investment is needed to support intercity trips without range anxiety issues and with acceptable delays. Additionally, through sensitivity analyses, the required infrastructure and battery investments to support intercity trips with acceptable delays are established for hypothetical increased market shares and battery size in the future.

42 ENGINEERING↗

Localizing Low-Grade Heat Using Hybrid Photonic-Phononic Materials

Creating next-generation devices capable of transducing waste heat into useful work will require building blocks designed to direct low-grade thermal energy at length scales well below the diffraction limit. Characterizing thermally induced energy transfer at the nanoscale, however, is a formidable task due to the simultaneous demand of high spatial and spectral resolution at infrared energies. Leveraging recent advancements in electron energy loss (EEL) and gain (EEG) spectroscopy, we reveal that individual nanostructures can concentrate energy by the resonant thermal excitation of their photonic Fabry–Pérot modes. Specifically, we show that the spatially localized gain signal increases upon in situ heating. Finally, theoretical modeling elucidates the mechanism for these observations by showing that a Purcell enhancement in the local photonic density of states drives the increased rate of infrared energy transfer from the ambient environment to each nanostructure.

36 MATERIALS SCIENCE↗

Fuzzy gauge theory for quantum computers

Continuous gauge theories, because of their bosonic degrees of freedom, have an infinite-dimensional local Hilbert space. Encoding these degrees of freedom on qubit-based hardware demands some sort of “qubitization” scheme, where one approximates the behavior of a theory while using only finitely many degrees of freedom. We propose a novel qubitization strategy for gauge theories, called “fuzzy gauge theory,” building on the success of the fuzzy σ -model in earlier work. We provide arguments that the fuzzy gauge theory lies in the same universality class as regular gauge theory, in which case its use would obviate the need of any further limit besides the usual spatial continuum limit. Furthermore, we demonstrate that these models are relatively resource-efficient for quantum simulations. Published by the American Physical Society 2024

Astronomy & Astrophysics↗

Hardware-in-the-Loop Co-simulation of Distribution Grid for Demand Response

In modern power systems, co-simulation is proposed as an enabler for analyzing the interactions between disparate systems. This paper introduces the co-simulation platform Virtual Grid Integration Laboratory (VirGIL) including Hardware-in-the-Loop testing, and demonstrates its potential to assess demand response strategies. VirGIL is based on a modular architecture using the Functional Mock-up Interface industrial standard to integrate new simulators. VirGIL combines state-of-the-art simulators in power systems, communications, buildings, and control. In this work, VirGIL is extended with a Hardware-in-the-Loop component to control the ventilation system of a real 12-story building in Denmark. VirGIL capabilities are illustrated in three scenarios: load following, primary reserves and load following aggregation. Experimental results show that the system can track one minute changing signals and it can provide primary reserves for up-regulation. Furthermore, the potential of aggregating several ventilation systems is evaluated considering the impact at distribution grid level and the communications protocol effect.

Rotger-Griful, Sergi↗

Modeling and Analysis of a Fast Charging Station and Evaluation of Service Quality for Electric Vehicles

The deployment of public charging infrastructure networks has been a major factor in enabling electric vehicle (EV) technology transition and must continue to support the adoption of this technology. DC fast charging (DCFC) increases customer convenience by lowering charging time, enables long-distance EV travel, and could allow the electrification of high-mileage fleets. Yet, high capital costs and uneven power demand have been major challenges to the widespread deployment of DCFC stations. There is a need to better understand DCFC stations' loading and customer service quality. Furthermore, the relationship between the initial investment decision on building certain number of ports and customer satisfaction should be quantified. This paper aims to analyze these aspects using one million vehicle days of travel data within the Columbus, OH, USA, region. Monte Carlo analysis is carried out in three types of areas - urban, suburban, and rural - to quantify the effect of uncertain parameters on DCFC station loading and service quality. Additional simulations based on a homogeneous vehicle population are carried out, and closed-form equations are derived therefrom to estimate charging duration and waiting time in the queue. Optimization of DCFC station design is also addressed through the number and capacity of ports.

33 ADVANCED PROPULSION SYSTEMS↗

Advanced Rooftop Control (ARC) Retrofit: Field-Test Results

The multi-year research study was initiated to find solutions to improve packaged equipment operating efficiency in the field. Pacific Northwest National Laboratory (PNNL), with funding from the U.S. Department of Energy’s (DOE’s) Building Technologies Office (BTO) and Bonneville Power Administration (BPA) conducted this research, development and demonstration (RD&D) study. Packaged equipment with constant speed supply fans is designed to provide ventilation at the design rate at all times when the fan is operating as required by building code. Although there are a number of hours during the day when a building may not be fully occupied or the need for ventilation is lower than designed, the ventilation rate cannot be adjusted easily with a constant speed fan. Therefore, modulating the supply fan in conjunction with demand controlled ventilation (DCV) will not only reduce the coil energy but also reduce the fan energy. The objective of this multi-year research, development and demonstration project was to determine the magnitude of energy savings achievable by retrofitting existing packaged rooftop air conditioners with advanced control strategies not ordinarily used for packaged units. First, through detailed simulation analysis, it was shown that significant energy (between 24% and 35%) and cost savings (38%) from fan, cooling and heating energy consumption could be realized when packaged air conditioning units with gas furnaces are retrofitted with advanced control packages (combining multi-speed fan control, integrated economizer controls and DCV). The simulation analysis also showed significant savings for heat pumps (between 20% and 60%). The simulation analysis was followed by an extensive field test of a retrofittable advanced rooftop unit (RTU) controller.

Katipamula, Srinivas↗

Part II: FY20 CIF Annual Report - LAPS: Lunar Autonomous Positioning System

This project concerns construction of an orbital and ground resource network that provides Position, Navigation, and Timing (PNT) services for lunar surface operations. While functionally similar to Global Navigation Satellite Systems (GNSS) for Earth, this system will instead build an automated PNT framework utilizing limited infrastructure on board orbiting assets along with a controlled number of highly accurate assets, or anchor nodes. The goal is to use advanced algorithms to autonomously coordinate on demand or as needed asset participation to achieve orbit determination and time synchronization of accuracy sufficient for end-user localization. Other proposed lunar PNT solutions, such as weak signal GPS, will not meet many mission localization requirements without additional user INS augmentation and a dedicated GNSS constellation would require prohibitive infrastructure development. This proposed effort, the Lunar Autonomous Positioning System (LAPS), instead offers a design that could be deployed in the near term and is facilitated by accessible hardware technology.

Kelley Hashemi↗

Measuring, mapping, and anticipating climate gentrification in Florida: Miami and Tampa case studies

This article introduces an experimental methodology to identify proxy indicators that are conceptually consistent with the processes of Climate Gentrification (“CG”), in which a change in demand preferences among consumers and investors drives the increased consumption for real estate, in part, on lower measures of physical risk from climate change. Evaluated through case studies in the state of Florida, this article builds on the integration of multiple datasets concerning rental properties, evictions, and socioeconomic data, as well as environmental risk indices to build a Climate Gentrification Risk Index (CGRI). In the Miami case study, we find that the CGRI identifies a hotly contested neighborhood that is already known to be in a state of transition consistent with the processes of CG. In the Tampa case, the index highlights a district that exhibits strong metrics for the future accelerated occurrence of CG. Our findings suggest that transitional land uses and flexible zoning in low-exposure areas are key elements for attracting new development consistent with CG and offer insight into the challenges that local governments face understanding the types and rates of change that may be catalyzed in the broader urban processes of public and private sector climate adaptation in the built environment.

Climate change↗

Simulation of a PCM Integrated Heat Pump Using Time-of-Use Utility Structure based Control Strategy for Demand Response

To mitigate the variation in demand on the electric grid, thermal energy storage (TES) is an alternative to electric batteries and constructing new peaking power plants. The aggressive carbon reduction goals of the United States are accelerating the electrification of building equipment. If space heating and cooling in the US were electrified using conventional heat pump technologies, the winter electric grid peak would approximately double. Integrating TES with heat pump (HP) enables electrification of space cooling and heating devices without overtaxing the grid.This paper evaluates the benefits of a novel phase change material (PCM) integrated heat pump configuration via simulation. A one-dimensional PCM heat exchanger model which discretizes the PCM tank and refrigerant tubes into small control volumes is developed. Each control volume can have different PCM temperatures, PCM properties, and heat transfer coefficients. The PCM tank is charged by a wrapped tank condenser and discharged by an internal refrigerant coil. The PCM heat exchanger model is integrated into DOE/ORNL Heat Pump Design Model for heat pump system simulation.To demonstrate the performance of the PCM integrated heat pump, a case study in Chicago was performed. A Time-of-Use utility structure-based control strategy is implemented to schedule the PCM tank charging and discharging mode switching. Compared with a conventional electric heat pump, the PCM integrated heat pump shows superior performance on load shifting and utility cost reduction. As a result, the proposed system demonstrates 24.6% utility saving for cooling application and 25.8% utility saving for heating application.

Li, Zhenning↗

Monitoring Based Commissioning: Benchmarking Analysis of 24 UC/CSU/IOU Projects

Buildings rarely perform as intended, resulting in energy use that is higher than anticipated. Building commissioning has emerged as a strategy for remedying this problem in non-residential buildings. Complementing traditional hardware-based energy savings strategies, commissioning is a 'soft' process of verifying performance and design intent and correcting deficiencies. Through an evaluation of a series of field projects, this report explores the efficacy of an emerging refinement of this practice, known as monitoring-based commissioning (MBCx). MBCx can also be thought of as monitoring-enhanced building operation that incorporates three components: (1) Permanent energy information systems (EIS) and diagnostic tools at the whole-building and sub-system level; (2) Retro-commissioning based on the information from these tools and savings accounting emphasizing measurement as opposed to estimation or assumptions; and (3) On-going commissioning to ensure efficient building operations and measurement-based savings accounting. MBCx is thus a measurement-based paradigm which affords improved risk-management by identifying problems and opportunities that are missed with periodic commissioning. The analysis presented in this report is based on in-depth benchmarking of a portfolio of MBCx energy savings for 24 buildings located throughout the University of California and California State University systems. In the course of the analysis, we developed a quality-control/quality-assurance process for gathering and evaluating raw data from project sites and then selected a number of metrics to use for project benchmarking and evaluation, including appropriate normalizations for weather and climate, accounting for variations in central plant performance, and consideration of differences in building types. We performed a cost-benefit analysis of the resulting dataset, and provided comparisons to projects from a larger commissioning 'Meta-analysis' database. A total of 1120 deficiency-intervention combinations were identified in the course of commissioning the projects described in this report. The most common location of deficiencies was in HVAC equipment (65% of sites), followed by air-handling and distributions systems (59%), cooling plant (29%), heating plants (24%), and terminal units (24%). The most common interventions were adjusting setpoints, modifying sequences of operations, calibration, and various mechanical fixes (each done in about two-thirds of the sites). The normalized rate of occurrence of deficiencies and corresponding interventions ranged from about 0.1/100ksf to 10/100ksf, depending on the issue. From these interventions flowed significant and highly cost-effective energy savings For the MBCx cohort, source energy savings of 22 kBTU/sf-year (10%) were achieved, with a range of 2% to 25%. Median electricity savings were 1.9 kWh/sf-year (9%), with a range of 1% to 17%. Peak electrical demand savings were 0.2 W/sf-year (4%), with a range of 3% to 11%. The aggregate commissioning cost for the 24 projects was $2.9 million. We observed a range of normalized costs from $0.37 to 1.62/sf, with a median value of $1.00/sf for buildings that implemented MBCx projects. Per the program design, monitoring costs as a percentage of total costs are significantly higher in MBCx projects (median value 40%) than typical commissioning projects included in the Meta-analysis (median value of 2% in the commissioning database). Half of the projects were in buildings containing complex and energy-intensive laboratory space, with higher associated costs. Median energy cost savings were $0.25/sf-year, for a median simple payback time of 2.5 years. Significant and cost-effective energy savings were thus obtained. The greatest absolute energy savings and shortest payback times were achieved in laboratory-type facilities. While impacts varied from project to project, on a portfolio basis we find MBCx to be a highly cost-effective means of obtaining significant program-level energy savings across a variety of building types. Energy savings are expected to be more robust and persistent for MBCx projects than for conventionally commissioned ones. Impacts of future programs can be maximized by benchmarking energy use and targeting the commissioning towards particularly energy-intensive facilities such as laboratories.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Concentrating Solar Power - Molten Salt Pump Development, Final Technical Report (Phase 1)

The purpose of this project is to develop a long shafted pump to operate at high temperatures for the purpose of producing energy with renewable resources. In Phase I of this three phase project we developed molten salt pump requirements, evaluated existing hardware designs for necessary modifications, developed a preliminary design of the pump concept, and developed refined cost estimates for Phase II and Phase III of the project. The decision has been made not to continue the project into Phases II and III. There is an ever increasing world-wide demand for sources of energy. With only a limited supply of fossil fuels, and with the costs to obtain and produce those fuels increasing, sources of renewable energy must be found. Currently, capturing the sun's energy is expensive compared to heritage fossil fuel energy production. However, there are government requirements on Industry to increase the amount of energy generated from renewable resources. The objective of this project is to design, build and test a long-shafted, molten salt pump. This is the type of pump necessary for a molten salt thermal storage system in a commercial-scale solar trough plant. This project is under the Department of Energy (DOE) Solar Energy Technologies Program, managed by the Office of Energy Efficiency and Renewable Energy. To reduce the levelized cost of energy (LCOE), and to meet the requirements of 'tomorrows' demand, technical innovations are needed. The DOE is committed to reducing the LCOE to 7-10 cents/kWh by 2015, and to 5-7 cents/kWh by 2020. To accomplish these goals, the performance envelope for commercial use of long-shafted molten salt pumps must be expanded. The intent of this project is to verify acceptable operation of pump components in the type of molten salt (thermal storage medium) used in commercial power plants today. Field testing will be necessary to verify the integrity of the pump design, and thus reduce the risk to industry. While the primary goal is to design a pump for a trough solar power plant system, the intent is for the design to be extensible to a solar power tower application. This can be accomplished by adding pumping stages to increase the discharge pressure to the levels necessary for a solar power tower application. This report incorporates all available conceptual design information completed for this project in Phase I.

14 SOLAR ENERGY↗

Improvements in Container Management of Transuranic and Low-Level Radioactive Waste Stored at the Central Waste Complex at Hanford

The Central Waste Complex (CWC) is the interim storage facility for Resource Conservation and Recovery Act (RCRA) mixed waste, transuranic waste, transuranic mixed waste, low-level and low-level mixed radioactive waste at the Department of Energy's (DOE's) Hanford Site. The majority of the waste stored at the facility is retrieved from the low-level burial grounds in the 200 West Area at the Site, with minor quantities of newly generated waste from on-site and offsite waste generators. The CWC comprises 18 storage buildings that house 13,000 containers. Each waste container within the facility is scanned into its location by building, module, tier and position and the information is stored in a site-wide database. As waste is retrieved from the burial grounds, a preliminary non-destructive assay is performed to determine if the waste is transuranic (TRU) or low-level waste (LLW) and subsequently shipped to the CWC. In general, the TRU and LLW waste containers are stored in separate locations within the CWC, but the final disposition of each waste container is not known upon receipt. The final disposition of each waste container is determined by the appropriate program as process knowledge is applied and characterization data becomes available. Waste containers are stored within the CWC based on their physical chemical and radiological hazards. Further segregation within each building is done by container size (55-gallon, 85-gallon, Standard Waste Box) and waste stream. Due to this waste storage scheme, assembling waste containers for shipment out of the CWC has been time consuming and labor intensive. Qualitatively, the ratio of containers moved to containers in the outgoing shipment has been excessively high, which correlates to additional worker exposure, shipment delays, and operational inefficiencies. These inefficiencies impacted the LLW Program's ability to meet commitments established by the Tri-Party Agreement, an agreement between the State of Washington, the Department of Energy, and the Environmental Protection Agency. These commitments require waste containers to be shipped off site for disposal and/or treatment within a certain time frame. Because the program was struggling to meet production demands, the Production and Planning group was tasked with developing a method to assist the LLW Program in fulfilling its requirements. Using existing databases for container management, a single electronic spreadsheet was created to visually map every waste container within the CWC. The file displays the exact location (e.g., building, module, tier, position) of each container in a format that replicates the actual layout in the facility. In addition, each container was placed into a queue defined by the LLW and TRU waste management programs. The queues were developed based on characterization requirements, treatment type and location, and potential final disposition. This visual aid allows the user to select containers from similar queues and view their location within the facility. The user selects containers in a centralized location, rather than random locations, to expedite shipments out of the facility. This increases efficiency for generating the shipments, as well as decreasing worker exposure and container handling time when gathering containers for shipment by reducing movements of waste containers. As the containers are collected for shipment, the remaining containers are segregated by queue, which further reduces future container movements. (authors)

42 ENGINEERING↗

IMPROVEMENTS IN CONTAINER MANAGEMENT OF TRANSURANIC (TRU) AND LOW LEVEL RADIOACTIVE WASTE STORED AT THE CENTRAL WASTE COMPLEX (CWC) AT HANFORD

The Central Waste Complex (CWC) is the interim storage facility for Resource Conservation & Recovery Act (RCRA) mixed waste, transuranic waste, transuranic mixed waste, low-level and low-level mixed radioactive waste at the Department of Energy's (DOE'S) Hanford Site. The majority of the waste stored at the facility is retrieved from the low-level burial grounds in the 200 West Area at the Site, with minor quantities of newly generated waste from on-site and off-site waste generators. The CWC comprises 18 storage buildings that house 13,000 containers. Each waste container within the facility is scanned into its location by building, module, tier and position and the information is stored in a site-wide database. As waste is retrieved from the burial grounds, a preliminary non-destructive assay is performed to determine if the waste is transuranic (TRU) or low-level waste (LLW) and subsequently shipped to the CWC. In general, the TRU and LLW waste containers are stored in separate locations within the CWC, but the final disposition of each waste container is not known upon receipt. The final disposition of each waste container is determined by the appropriate program as process knowledge is applied and characterization data becomes available. Waste containers are stored within the CWC based on their physical chemical and radiological hazards. Further segregation within each building is done by container size (55-gallon, 85-gallon, Standard Waste Box) and waste stream. Due to this waste storage scheme, assembling waste containers for shipment out of the CWC has been time consuming and labor intensive. Qualitatively, the ratio of containers moved to containers in the outgoing shipment has been excessively high, which correlates to additional worker exposure, shipment delays, and operational inefficiencies. These inefficiencies impacted the LLW Program's ability to meet commitments established by the Tri-Party Agreement, an agreement between the State of Washington, the Department of Energy, and the Environmental Protection Agency. These commitments require waste containers to be shipped off site for disposal and/or treatment within a certain time frame. Because the program was struggling to meet production demands, the Production and Planning group was tasked with developing a method to assist the LLW Program in fulfilling its requirements. Using existing databases for container management, a single electronic spreadsheet was created to visually map every waste container within the CWC. The file displays the exact location (e.g., building, module, tier, position) of each container in a format that replicates the actual layout in the facility. In addition, each container was placed into a queue defined by the LLW and TRU waste management programs. The queues were developed based on characterization requirements, treatment type and location, and potential final disposition. This visual aid allows the user to select containers from similar queues and view their location within the facility. The user selects containers in a centralized location, rather than random locations, to expedite shipments out of the facility. This increases efficiency for generating the shipments, as well as decreasing worker exposure and container handling time when gathering containers for shipment by reducing movements of waste container. As the containers are collected for shipment, the remaining containers are segregated by queue, which further reduces future container movements.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

An assessment of existing barriers to market adoption of thermal energy storage in buildings based on interviews with stakeholders

The United States administration recently established a goal of reducing greenhouse gas emissions by half below 2005 levels by 2030 and becoming a carbon-neutral economy by 2050. The transition to renewable energy sources may be significantly aided by energy storage. Energy storage could smooth the delivery of variable or intermittent renewable energy sources such as wind, hydro, and sun by storing excess renewable energy when it’s available and delivering it back when renewable energy production is low. Thermal energy storage (TES) is a way that stores thermal energy by heating or cooling a storage medium, which is then used for space heating and cooling, industrial processes, or power generation purposes later. This TES operation could lessen the demand for electricity in both the winter's and the summer's peak hours of electricity. While there are various studies that focus on the advancements and successes of TES technology, less attention is placed on its market adoption. Therefore, the current study undertakes survey-based interview research to understand the existing market barriers hindering TES application in buildings. A series of interviews were performed in this study with individuals from various backgrounds, ranging from homeowners to market specialists who work for TES manufacturers and utility companies. According to the responses obtained during the interviews, they strongly believe that TES has a high potential to contribute to the nation's grid stability and decarbonization goals, however, there are several barriers that prevent homeowners and heat pump manufacturers from investing in TES applications. The current study divided the responses from various background groups into categories to better understand the current challenges for TES applications in buildings. These responses range from payback concerns from homeowners to the need to develop a new metric to represent the benefits of TES from the heat pump and TES manufacturers. The findings from this study can be used by policymakers, utility companies, and manufacturers to better understand present obstacles and develop strategies to overcome them.

Prem Anand Jayaprabha, Jyothis Anand↗