Beam-induced Electron Loading Effects in High Pressure Cavities for a Muon Collider

Ionization cooling is a critical building block for the realization of a muon collider. To suppress breakdown in the presence of the external magnetic field, an idea of using an RF cavity filled with high pressure hydrogen gas is being considered for the cooling channel design. One possible problem expected in the high pressure RF cavity is, however, the dissipation of significant RF power through the beam-induced electrons accumulated inside the cavity. To characterize this detrimental loading effect, we develop a simplified model that relates the electron density evolution and the observed pickup voltage signal in the cavity, with consideration of several key molecular processes such as the formation of the polyatomic molecules, recombination and attachment. This model is expected to be compared with the actual beam test of the cavity in the MuCool Test Area (MTA) of Fermilab.

43 PARTICLE ACCELERATORS↗

Design of Helical Cooling Channel for Muon Collider

Fast muon beam six dimensional (6D) phase space cooling is essential for muon colliders. The Helical Cooling Channel (HCC) uses hydrogen-pressurized RF cavities imbedded in a magnet system with solenoid, helical dipole, and helical quadrupole components that provide the continuous dispersion needed for emittance exchange and effective 6D beam cooling. A series of HCC segments, each with sequentially smaller aperture, higher magnetic field, and higher RF frequency to match the beam size as it is cooled, has been optimized by numerical simulation to achieve a factor of 10{sup 5} emittance reduction in a 300 m long channel with only a 40% loss of beam. Conceptual designs of the hardware required for this HCC system and the status of the RF studies and HTS helical solenoid magnet prototypes are described.

43 PARTICLE ACCELERATORS↗

Colliding Nuclei at High Energy

Physicist Peter Steinberg explains what happens when atomic nuclei traveling at close to the speed of light smash together in Brookhaven Lab's Relativistic Heavy Ion Collider (RHIC).

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Implications of HARP Results for the Energy of the Proton Driver for a Neutrino Factory and Muon Collider

Cross-section data from the HARP experiment for pion production by protons from a tantalum target have been convoluted with the acceptance of the front-end channel for the proposed neutrino factory or muon collider and integrated over the full phase space measured by HARP, to determine the beam-energy dependence of the muon yield. This permits a determination of the optimal beam energy for the proton driver for these projects. The cross-section data are corrected for the beam-energy dependent 'amplification' due to the development of hadronic showers in a thick target. The conclusion is that, for constant beam power, the yield is maximum for a beam energy of about 7 GeV, but it is within 10% of this maximum for 4 < T{sub beam} < 11 GeV, and within 20% of the maximum for T{sub beam} as low as 2 GeV. This result is insensitive to which of the two HARP groups results are used, and to which pion generator is used to compute the thick target effects.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Beam Test of a High Pressure Cavity for a Muon Collider

To demonstrate the feasibility of a high pressure RF cavity for use in the cooling channel of a muon collider, an experimental setup that utilizes 400-MeV Fermilab linac proton beam has been developed. In this paper, we describe the beam diagnostics and the collimator system for the experiment, and report the initial results of the beam commissioning. The transient response of the cavity to the beam is measured by the electric and magnetic pickup probes, and the beam-gas interaction is monitored by the optical diagnostic system composed of a spectrometer and two PMTs.

43 PARTICLE ACCELERATORS↗

Muon Collider design status

Muon Collider (MC) - proposed by G.I. Budker and A.N. Skrinsky a few decades ago - is now considered as the most exciting option for the energy frontier machine in the post-LHC era. A national Muon Accelerator Program (MAP) is being formed in the USA with the ultimate goal of building a MC at the Fermilab site with c.o.m. energy in the range 1.5-3 TeV and luminosity of {approx} 1.5 {center_dot} 10{sup 34} cm{sup -2} s{sup -1}. As the first step on the way to MC it envisages construction of a Neutrino Factory (NF) for high-precision neutrino experiments. The baseline scheme of the NF-MC complex is presented and possible options for its main components are discussed.

43 PARTICLE ACCELERATORS↗

Potential-Well Distortion, Microwave Instability, and Their Effects with Colliding Beams at KEKB

Microwave instability in the Low Energy Ring of KEKB was studied using a broadband impedance model. The model gave excellent descriptions of longitudinal dynamics for both positive and negative momentum compactions. Moreover, it predicted that the threshold of microwave instability was a factor of two lower than the machine nominal operating bunch current. The prediction was confirmed by a measurement using the Belle detector. Furthermore, we integrated the longitudinal wakefield into the beam-beam simulation and applied it to study the combined effects in KEKB. As a result, the beam-beam simulation became truly three-dimensional with emittance growth in all three dimensions simultaneously as the beam currents increase. In addition, an observed mystery of asymmetry in the horizontal scan could also be explained by our simulations.

43 PARTICLE ACCELERATORS↗

Accelerator Science: Collider vs. Fixed Target

Particle physics experiments employ high energy particle accelerators to make their measurements. However there are many kinds of particle accelerators with many interesting techniques. One important dichotomy is whether one takes a particle beam and have it hit a stationary target of atoms, or whether one takes two counter rotating beams of particles and smashes them together head on. In this video, Fermilab’s Dr. Don Lincoln explains the pros and cons of these two powerful methods of exploring the rules of the universe.

43 PARTICLE ACCELERATORS↗

Future Circular Colliders

While the LHC is currently the highest energy particle accelerator ever built, nothing is forever. In this video, Fermilab’s Dr. Don Lincoln discusses a new particle accelerator currently under discussion. This accelerator will dwarf the LHC, fully 60 miles around and will accelerate protons to seven times higher energy. The project is merely in the discussion stages and it is a staggering endeavor, but it is the next natural step in our millennium long journey to understand the universe.

43 PARTICLE ACCELERATORS↗

Hadronic mono- W ' probes of dark matter at colliders

Particle collisions at the energy frontier can probe the nature of invisible dark matter via production in association with recoiling visible objects. We propose a new potential production mode, in which dark matter is produced by the decay of a heavy dark Higgs boson radiated from a heavy W' boson. In such a model, motivated by left-right symmetric theories, dark matter would not be pair produced in association with other recoiling objects due to its lack of direct coupling to quarks or gluons. We study the hadronic decay mode via W' → tb and estimate the LHC exclusion sensitivity at 95% confidence level to be 10 2 - 10 5 fb for W' boson masses between 250 and 1750 GeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Design and simulated performance of calorimetry systems for the ECCE detector at the electron ion collider

Here, we describe the design and performance the calorimeter systems used in the ECCE detector to achieve the overall performance specifications cost-effectively with careful consideration of appropriate technical and schedule risks. The calorimeter systems consist of three electromagnetic calorimeters, covering the combined pseudorapidity range from -3.7 to 3.8 and two hadronic calorimeters covering a combined range of -1.1<η<3.8. Key calorimeter performances which include energy and position resolutions, reconstruction efficiency, and particle identification will be presented.