Search NASA⌕ Search

SEARCH · Search NASA

Results for “Control Room”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

New concept of radiolytic synthesis of gold nanoparticles in continuous flow

Radiolytic synthesis has been used to produce a plethora of unsupported and supported metallic nanoparticles in batch. As proof of a new concept, we evaluated the formation of gold nanoparticles by radiolytic synthesis in continuous flow using a millifluidic reactor. A mixture of gold ions solution, branched polyethyleneimine, and ethylene glycol yielded gold nanoparticles with a mean size of 3.4 ± 1.0 nm after irradiation with an X-ray irradiator (127 Gy/min) at an absorbed dose of 5.1 kGy. The morphology and size distribution of gold nanoparticles was influenced by AgNO 3 , where its absence resulted in a mean size of 20.9 ± 15.8 nm. The radiolytic synthesis of gold nanoparticles in continuous flow was achieved in short reaction times (<60 min), at room temperature, and with low concentrations of both stabilizing and reducing agents. Furthermore, these results demonstrate the potential of radiolytic synthesis in continuous flow for high-throughput formation of metallic nanoparticles with controlled specifications in size and distribution.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Design Synthesis of Nitrogen-Doped TiO 2 @Carbon Nanosheets toward Selective Nitroaromatics Reduction under Mild Conditions

The development of a facile, low-cost, and eco-friendly approach to the synthesis of aromatic amines remains a great scientific challenge. TiO 2 , as a low-cost and earth abundant metal oxide, is usually not active for thermo-catalyzed nitro reduction. Here, we report a composite nanosheet catalyst, composed of nitrogen-doped TiO 2 and carbon (N-TiO 2 @C), which exhibits highly efficient, thermo-catalytic performance for selective nitroaromatic reduction at room temperature. The N-TiO 2 @C nanosheet catalyst is synthesized via a facile approach where C 3 N 4 nanosheets are utilized not only as a structure-directing agent to control the shape, size, and crystal phase of TiO 2 but also as a source of nitrogen for doping into both TiO 2 and carbon nanosheets. Furthermore, the origin of the superior performance of the N-TiO 2 @C nanosheet composite catalyst, along with a possible nitroaromatic reduction mechanism, has also been explored.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Anisotropic 2D excitons unveiled in organic-inorganic quantum wells

Here we report that two-dimensional (2D) excitons arise from electron-hole confinement along one spatial dimension. Such excitations are often described in terms of Frenkel or Wannier limits according to the degree of exciton spatial localization and the surrounding dielectric environment. In hybrid material systems, such as the 2D perovskites, the complex underlying interactions lead to excitons of an intermediate nature, whose description lies somewhere between the two limits, and a better physical description is needed. Here, we explore the photophysics of a tuneable materials platform where covalently bonded metal-chalcogenide layers are spaced by organic ligands that provide confinement barriers for charge carriers in the inorganic layer. We consider self-assembled, layered bulk silver benzeneselenolate, [AgSePh] ∞ , and use a combination of transient absorption spectroscopy and ab initio GW plus Bethe-Salpeter equation calculations. We demonstrate that in this non-polar dielectric environment, strongly anisotropic excitons dominate the optical transitions of [AgSePh] ∞ . We find that the transient absorption measurements at room temperature can be understood in terms of low-lying excitons confined to the AgSe planes with in-plane anisotropy, featuring anisotropic absorption and emission. Finally, we present a pathway to control the exciton behaviour by changing the chalcogen in the material lattice. Our studies unveil unexpected excitonic anisotropies in an unexplored class of tuneable, yet air-stable, hybrid quantum wells, offering design principles for the engineering of an ordered, yet complex dielectric environment and its effect on the excitonic phenomena in such emerging materials.

36 MATERIALS SCIENCE↗

Power conversion in SnS photocathodes made by electrochemical growth is limited by recombination at (002) buried facets

Herzenbergite α-SnS is a promising p-type semiconductor for photovoltaic and solar fuel applications, but current devices are plagued by substantial photovoltage losses. Here we use vibrating Kelvin probe surface photovoltage for the first time to study the recombination losses in microcrystalline SnS photoelectrodes. α-SnS films of varied crystal orientation, size, and shape are obtained by electrochemical growth from aqueous tin( II ) chloride and sodium thiosulfate solutions near room temperature. After application of a CdS passivation layer, the films function as photocathodes for the methylviologen reduction reaction. Photoelectrochemical and surface photovoltage measurements reveal that the performance of these devices is sensitively controlled by mainly the SnS crystal orientation and to a lesser extent by the grain size. For example, the highest charge recombination rates of 8.97 × 10 14 s −1 cm −2 and lowest photocurrent (0.73 mA cm −2 ) and lowest photovoltage (0.12 V) occur for SnS films containing 500 nm crystals with irregular shapes and SnS lattices tilted away from the (001) orientation. On the other hand, the best performance (1.62 mA cm −2 , 0.16 V, 3.32 × 10 12 s −1 cm −2 ) is seen for 1100 nm fully (001) oriented SnS nanoplates. Furthermore, these findings agree with improved charge carrier mobility in the 001 direction and they also show that charge recombination in SnS films occurs mainly at dangling Sn–S bonds at buried (002) facets. Such buried interfaces need to be suppressed for optimized solar energy conversion with SnS.

Najaf, Zainab [University of California, Davis, CA↗

New customizable phased array UT instrument opens door for furthering research and better industrial implementation

Phased array UT as an inspection technique in itself continues to gain wide acceptance. However, there is much room for improvement in terms of implementation of Phased Array (PA) technology for every unique NDT application across several industries (e.g. oil and petroleum, nuclear and power generation, steel manufacturing, etc.). Having full control of the phased array instrument and customizing a software solution is necessary for more seamless and efficient inspections, from setting the PA parameters, collecting data and reporting, to the final analysis. NDT researchers and academics also need a flexible and open platform to be able to control various aspects of the phased array process. A high performance instrument with advanced PA features, faster data rates, a smaller form factor, and capability to adapt to specific applications, will be discussed.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Phase transition and electronic structure evolution of MoTe 2 induced by W substitution

We report that the transition-metal dichalcogenide compounds MoTe 2 and WTe 2 are polymorphic with both semiconducting and metallic phases. The thermodynamically stable phase of WTe 2 at room temperature is orthorhombic and metallic and displays a wide range of interesting phenomena including type-II Weyl fermions, titanic magnetoresistance and superconductivity in bulk, and quantum spin Hall insulator behavior in the monolayer case. On the other hand, the stable phase of MoTe 2 at room temperature is a trigonal prismatic semiconductor that has a direct gap in the monolayer with strong spin-orbit coupling. The alloy series Mo 1-x W x Te 2 thus offers the possibility for tuning the structural and, consequently, electronic phases via tuning of the composition. Here, we report comprehensive studies of the electronic structure of Mo 1-x W x Te 2 alloys using angle-resolved photoemission spectroscopy and first-principles calculations as a function of composition. At room temperature, we find a sharp boundary between the orthorhombic and the trigonal prismatic phases at x = 0.10 using structural characterization. Finally, we also show that by compositional tuning it is possible to control the band inversion in this series of compounds thus yielding important consequences for topological surface states.

36 MATERIALS SCIENCE↗

Tunable electroresistance and electro-optic effects of transparent molecular ferroelectrics

Recent progress in molecular ferroelectrics (MOFEs) has been overshadowed by the lack of high-quality thin films for device integration. We report a water-based air-processable technique to prepare large-area MOFE thin films, controlled by supersaturation growth at the liquid-air interface under a temperature gradient and external water partial pressure. We used this technique to fabricate ImClO4 thin films and found a large, tunable room temperature electroresistance: a 20-fold resistance variation upon polarization switching. The as-grown films are transparent and consist of a bamboo-like structure of ($2,\overline{1},0$) and ($1,0,\overline{2}$) structural variants of R3m symmetry with a reversible polarization of 6.7 μC/cm 2 . The resulting ferroelectric domain structure leads to a reversible electromechanical response of d 33 = 38.8 pm/V. Polarization switching results in a change of the refractive index, n, of single domains, $\frac{Δn}{n}$ = 0.3. The remarkable combination of these characteristics renders MOFEs a prime candidate material for new nanoelectronic devices. The information that we present in this work will open a new area of MOFE thin-film technologies.

36 MATERIALS SCIENCE↗

Production, quality assurance and quality control of the SiPM Tiles for the DarkSide-20k Time Projection Chamber

The DarkSide-20k dark matter direct detection experiment will employ a 21 m 2 silicon photomultiplier (SiPM) array, instrumenting a dual-phase 50 tonnes liquid argon Time Projection Chamber (TPC). SiPMs are arranged into modular photosensors called Tiles, each integrating 24 SiPMs onto a printed circuit board (PCB) that provides signal amplification, power distribution, and a single-ended output for simplified readout. Tiles are further grouped into Photo-Detector Units (PDUs). This paper details the production of the Tiles and the Quality Assurance and Quality Control (QA-QC) protocol established to ensure their performance and uniformity. The production and QA-QC of the Tiles are carried out at Nuova Officina Assergi (NOA), an ISO-6 clean room facility at LNGS. This process includes wafer-level cryogenic characterisation, precision die attaching, wire bonding, and extensive electrical and optical validation of each Tile. The overall production yield exceeds 83.5%, matching the requirements of the DarkSide-20k production plan. These results validate the robustness of the Tile design and its suitability for operation in a cryogenic environment.

Acerbi, F. [Fondazione Bruno Kessler]↗

Radiation Mapping UAV [Poster]

The NuMI (Neutrinos at the Main Injector) target system delivers a high-energy flux of muon-neutrinos towards a detector more than 800 km away with the goal of better understanding the origin of the universe and its evolution. The target system becomes radioactive because it is irradiated by a sub-Mega-Watt power proton beam. Radiological hazard is one of critical issues for a radiological worker which limits the iractivities near the target system; however, they often need to quantify the radiation level of the target system manually. Thus, the objective of this project is to reduce their exposure to radiation while improving the accuracy of the measurements. A quadcopter UAV fitted with a radiation dosimeter is ideal to traverse the irradiated environment as it can be deployed in any space and requires minimal hardware integration to the test room. Due to the lack of indoor GPS signal, this UAV utilizes a series of ultrasonic beacons that release several varied-frequency pulses simultaneously in order to localize the drone. The flight controller returns a 3D coordinate tied to the radiation data to understand precisely where radiation spikes are being emitted from the horn. The flight controller stores log data that can be processed into an easily interpretable map of radiation intensities. The radiation map serves as one of the primary references for planning the transportation of the NuMI horn.

43 PARTICLE ACCELERATORS↗

Simulations of Criticality Control Overpack Container Compaction at the Waste Isolation Pilot Plant

Criticality Control Overpack (CCO) containers are being considered for the disposal of defense-related nuclear waste at the Waste Isolation Pilot Plant (WIPP). At WIPP, these containers would be placed in underground disposal rooms, which will naturally close and compact the containers closer to one another over several centuries. This report details simulations to predict the final container configuration as an input to nuclear criticality assessments. Each container was discretely modeled, including the plywood and stainless steel pipe inside the 55-gallon drum, in order to capture its complex mechanical behavior. Although these high-fidelity simulations were computationally intensive, several different material models were considered in an attempt to reasonably bound the horizontal and vertical compaction percentages. When exceptionally strong materials were used for the containers, the horizontal and vertical closure respectively stabilized at 43:9 % and 93:7 %. At the other extreme, when the containers completely degraded and the clay seams between the salt layers were glued, the horizontal and vertical closure reached respective final values of 48:6 % and 100 %.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Effects of electron irradiation on large insulating surfaces used for European Communications Satellites

Samples of aluminized Kapton used for passive thermal control on the VHF shield and the antenna dish of ESA's OTS satellite and its derivatives were subjected to an incident electron beam of 25 keV and irradiated for 8 hours at room temperature and at -173 C under a vacuum of the 10 to the minus 6 th power torr. Visual observations during electron irradiation, measurements of leakage current and discharge characteristics, and material degradation following completion of irradiation are discussed.

Reddy, J.↗

The dc power control for a liquid-fed resistojet

A simple breadboard power controller was designed and demonstrated for a new liquid-fed water resistojet. The 1-piece laboratory model thruster has an integrated vaporizer/superheater using a single heating element. Heater temperature was maintained at or near a preset reference value with the closed loop controller providing pulse width modulated (PWM) dc power into the thruster heater. A combined thruster, temperature readout, PWM transfer function was experimentally determined. This transfer function was used to design a proportional plus integral controller that demonstrated zero steady state error, conservative stability margins and adequate transient response to step changes in propellant flow rate, input voltage and temperature reference. Initial turn-on temperature overshoot from room temperature to a 650 C setpoint was 80 C. In addition, EMI was alleviated by reducing heater dI/dt and dV/dt using a simple diode-inductor-capacitor network. Based on limited initial tests, thruster preheat with no propellant flow was necessary to achieve stable system operation during startup. Breadboard power efficiency was 99 percent at 1 kW, and component mass was 0.4 kg excluding the power loss and mass of an input filter required for spacecraft integration.

Gruber, Robert P.↗

dc power control for a liquid-fed resistojet

A simple breadboard power controller was designed and demonstrated for a new liquid-fed water resistojet. The 1-piece laboratory model thruster has an integrated vaporizer/superheater using a single heating element. Heater temperature was maintained at or near a preset reference value with the closed loop controller providing pulse width modulated (PWM) dc power into the thruster heater. A combined thruster, temperature readout, PWM transfer function was experimentally determined. This transfer function was used to design a proportional plus integral controller that demonstrated zero steady state error, conservative stability margins and adequate transient response to step changes in propellant flow rate, input voltage and temperature reference. Initial turn-on temperature overshoot from room temperature to a 650 C setpoint was 80 C. In addition, EMI was alleviated by reducing heater dI/dt and dV/dt using a simple diode-inductor-capacitor network. Based on limited initial tests, thruster preheat with no propellant flow was necessary to achieve stable system operation during startup. Breadboard power efficiency was 99 percent at 1 kW, and component mass was 0.4 kg excluding the power loss and mass of an input filter required for spacecraft integration.

Gruber, Robert P.↗

Man-machine interfaces in health care

The surgeon, like the pilot, is confronted with an ever increasing volume of voice, data, and image input. Simultaneously, the surgeon must control a rapidly growing number of devices to deliver care to the patient. The broad disciplines of man-machine interface design, systems integration, and teleoperation will play a role in the operating room of the future. The purpose of this communication is to report the incorporation of these design concepts into new surgical and laser delivery systems. A review of each general problem area and the systems under development to solve the problems are presented.

Charles, Steve↗

Incorporation of metal nanoparticles into wood substrate and methods

Metal nanoparticles were incorporated into wood. Ionic liquids were used to expand the wood cell wall structure for nanoparticle incorporation into the cell wall structure. Nanoparticles of elemental gold or silver were found to be effective surface enhanced Raman spectroscopy (SERS) imaging contrast or sensing agents. Nanoparticles of elemental iron were found to be efficient microwave absorbers and caused localized heating for disrupting the integrity of the lignocellulosic matrix. Controls suggest that the localized heating around the iron nanoparticles reduces losses of cellulose in the form of water, volatiles and CO.sub.2. The ionic liquid is needed during the incorporation process at room temperature. The use of small amounts of ionic liquid combined with the absence of an ionic liquid purification step and a lower energy and water use are expected to reduce costs in an up-scaled pretreatment process.

59 BASIC BIOLOGICAL SCIENCES↗

Status of Electronics Upgrades to the LANL Green is Clean Phoswich Detector Systems - 16419

Los Alamos National Laboratory radiological facilities produce low-density room trash that, in many cases, is not contaminated with radioactivity. It has been estimated that 50 to 90% of low-density room trash is free of radioactive contamination and eligible for inclusion in LANL's Green is Clean (GIC) program. The GIC program is a verification program for non-regulated waste from radiation controlled areas that has been actively segregated as nonradioactive through the use of the waste generator's acceptable knowledge. The GIC program has employed two large area Phoswich gamma ray detector systems (HERCULES and ZEUS) to assay and verify that GIC candidate waste meets free release disposal requirements. The large area (127 cm{sup 2}) Phoswich detectors consist of a thin NaI front crystal (3 mm thick) that is optically coupled to a thick CsI back crystal (50 mm thick). The crystals are set in an oxygen-free high-conductivity copper housing with a very thin (0.025 mm) aluminum entrance window. The scintillation properties of the two crystals are different enough to allow the system's electronic components to identify the origin of any pulse. The original systems utilize Nuclear Instrumentation Module (NIM) electronics to process the detector signals. These electronic modules provide the buffering, amplification, and pulse shape analyzer needed for the proper presentation of signals to the custom Phosmux router module. The router module separates the sodium iodide and cesium iodide signals by their rise times and transfers this information into the computer-mounted multichannel analyzer, a Canberra Model S-100 system. While these NIM Bin counting electronics configurations have been effective for approximately 20 years of operation, they are bulky requiring numerous modules per detector and the important Phosmux module is no longer manufactured by LANL. Modern advancement of commercial counting electronics now offer more compact options for equivalent detector signal processing. A pulse shape discriminator module, the DGF Pixie-4, made by XIA LLC, has been identified that can replace the majority of the original NIM bin electronics in a much more compact chassis - one Pixie-4 replaces four NIM amplifiers and four NIM PSAs and fits in a small National Instruments{sup TM} chassis. Thus, LANL has initiated a system upgrade project to replace the historic NIM electronics with the XIA Pixie4 and associated configuration software. The hardware for one Phoswich systems has been procured for the project and the configuration software, customized for the LANL Phoswich detector application, has been written by the manufacturer. Initial setup and optimization of the Pixie-4 configuration has been performed. Qualitative and quantitative baseline comparisons to the NIM electronics has been performed. Good agreement of key low energy gamma lines between the systems has allowed 'Proof of Concept' to be concluded. Further optimization and performance evaluations are in progress. Modifications to the LabVIEW{sup TM} based operating software (originally written by VI Control Systems Ltd.) are being performed by a LANL LabVIEW{sup TM} programmer to accommodate the electronics upgrade. A new LabVIEW{sup TM} interface to control the Pixie-4 has already been developed. Final optimization and testing, formal software QA, and revisions to operating procedures are in progress to achieve completion of the GIC system upgrade project. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Means and procedures for stopping a criticality accident in the MELOX homogeniser

The purpose of this paper is to describe the organizational and material changes as well as the intervention procedure in order to stop a hypothetical criticality accident in the MELOX homogenizer. By extension, this study will take into account a criticality accident in other workstations of the production chain. It establishes that stopping a criticality accident in the homogenizer requires that 20 kg of hafnium oxide will be injected into its tank. This admission will be carried out in two stages: initially operators have to pour 20 kg of hafnium oxide into a jar, then in a second step this jar will be brought, using a manual mode controlled by an automation technician, into the homogenizing workstation from a distant controller. Then, from this distant controller, the technician will blend the MOX with the hafnium in the homogenizer, and eventually stop the accident. These interventions involve the inhibition of safety PLC and the permanent radiation monitoring in the rooms where human presence is necessary. The foreseen radiation doses are studied and are encouraging. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Electronics Upgrades to the Green is Clean Phoswich Detector Systems and Programmatic Implementation at LANL - Phase II Completion - 18403

Los Alamos National Laboratory (LANL) radiological facilities produce low-density room trash that, in many cases, is not contaminated with radioactivity. It has been estimated that 50 to 90% of low-density room trash is free of radioactive contamination and eligible for inclusion in LANL's Green is Clean (GIC) program. The GIC program is a verification program for non-regulated waste from radiation controlled areas that has been actively segregated as nonradioactive through the use of the waste generator's acceptable knowledge. The GIC program has employed two large area Phoswich gamma ray detector systems (HERCULES and ZEUS) to verify that GIC candidate low-density waste contains no radioactivity above background. The large area (127 cm{sup 2}) Phoswich detectors consist of a thin NaI front crystal (3 mm thick) that is optically coupled to a thick CsI back crystal (50 mm thick). The scintillation properties of the two crystals are different enough to allow the system's electronic components to identify the origin of any pulse. The original systems utilize Nuclear Instrumentation Module (NIM) electronics to process the detector signals. The electronics currently in use by the systems are out of date and some components are no longer manufactured. In 2015, phase I upgrades to the GIC detector systems were completed. Phase I objectives included identifying more modern commercially available electronics that could replace the NIM electronics. A pulse shape discriminator (PSD) module, the Digital Gamma Finder (DGF) Pixie-4 made by XIA LLC, that fits in a compact National Instruments{sup TM} PXI chassis was identified to replace the majority of the original NIM bin electronics - a single Pixie-4 module replaces four NIM amplifiers and four NIM pulse shape analyzers (PSAs). Another phase I objective was to show that that new PSD could separate out the NaI and CsI detector signals in a manner equivalent to or better than the NIM electronics. Proof of concept was achieved in 2015 when a prototype upgrade system on ZEUS was built and tested and gating parameter settings were determined that successfully separated the NaI and CsI signals. Phase II required establishing a LabVIEW software interface with Pixie-4 electronics in lieu of the manufacturer provided Pixie-4 software called the Pixie Viewer. In addition, phase II included 1) final optimization of the gating parameters on the prototype Pixie-4 ZEUS system, 2) finalizing Requirements, Design and Test Plan documents, 3) LabVIEW software interface quality assurance (QA) testing, 4) setting up the HERCULES system with the Pixie-4 upgrade electronics, 5) check source and background calibration of both systems, 6) absolute efficiency determination on both systems and 7) procedure revisions and implementation of both systems into routine operations. In 2017 phase II was completed including the preparation of detailed Requirements, Design and Test Plan documents. The LabVIEW interface software that communicates and controls the Pixie-4 has been completed, merged with the preexisting LabVIEW operations software and fully tested. Gating parameter optimization, configuration of HERCULES with the Pixie-4 electronics, check source and background calibrations and absolute efficiency determinations have all been performed - quantitative results are presented in the full paper. For performance validation, comparison measurements of actual GIC bags on both the HERCULES system using the old NIM Bin electronics and the ZEUS system using the upgraded Pixie-4 electronics have been done and evaluated. Finally, procedure revisions and implementation of both systems into routine operations is currently in process and planned to be complete by the end of calendar year 2017. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗