Search NASA⌕ Search

SEARCH · Search NASA

Results for “Count”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

SU-E-T-166: Evaluation of Integral Dose in Intensity-Modulated Radiotherapy and Volumetric Modulated Arc Therapy for Head and Neck Cancer Patient

Purpose: Volumetric Modulated Arc Therapy (VMAT) usually achieves higher conformity of radiation doses to targets and less delivery time than Intensity Modulated Radiation Therapy (IMRT). We hypothesized that VMAT will increase integral dose (ID) to patients which will decrease the count of white blood count (WBC) lymphocytes, and consequently has a subsequent impact on the immune system. The purpose of this study is to evaluate the ID to patients undergoing IMRT and VMAT for Head and Neck cancers and its impact on the immune system. Methods: As a pilot study, 30 head and neck patients who received 9-fields IMRT or 3-arcs Radip-Arcbased VMAT were included in this study. Ten of these patients who received the VMAT plans were re-planned using IMRT with the same objectives. ID was calculated for all cases. All patients also had a baseline WBC obtained prior to treatment, and 3 sets of labs drawn during the course of radiation treatment. Results: For the 10 re-planned patients, the mean ID was 13.3 Gy/voxel (range 10.2–17.5 Gy/voxel) for the 9-fields IMRT plans, and was 15.9 Gy/voxel (range 12.4-20.9 Gy/voxel) for the 3-Arc VMAT plan (p=0.01). The integral dose was significant correlated with reducing WBC count during RT even when controlling for concurrent chemotherapy (R square =0.56, p=0.008). Conclusion: Although VMAT can deliver higher radiation dose conformality to targets, this benefit is achieved generally at the cost of greater integral doses to normal tissue outside the planning target volume (PTV). Lower WBC counts during RT were associated with higher Integral doses even when controlling for concurrent chemotherapy. This study is ongoing in our Institution to exam the impact of integral doses and WBC on overall survival.

60 APPLIED LIFE SCIENCES↗

Comparative testing of various flow-cell detectors fabricated using CaF{sub 2} solid scintillator

A monitoring system based on a flow-cell detector was developed for measuring the tritium concentration in water. The flow-cell detector was fabricated using a granular CaF{sub 2} solid scintillator. This system does not use a liquid scintillation counting system and does not generate radioactive organic liquid waste. Moreover, continuous real-time measurements are possible, in contrast to a liquid scintillation counting system, which requires batch measurements. For further development of the system, four flow-cell detectors were fabricated. They included a single 3-mm-diameter cell, three 3-mm-diameter cells in series, a single 5-mm-diameter cell, and three 5-mm-diameter cells in series. Continuously flowing water containing tritium at various concentrations was passed through the flow cells, and tritium count were measured for 600 and 10000 s. Investigating the relation between the count rate and concentration, the three 5-mm-diameter cells were most sensitive, with a linear relation maintained down to approximately 2 Bq/ml and 10 Bq/ml for 10000- and 600-s measurements, respectively. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The AGS Ggamma Meter and Calibrating the Gauss Clock

During AGS Polarized Proton acceleration periods, one output from the AGS Ggamma Meter, namely the energy (or Ggamma) calculated from the magnetic field in the AGS main magnets and the beam radius- both measured in particular instant, is used to figure out the times in the AGS magnet acceleration cycle when the beam passes through a particular set of depolarizing resonances. The resonance set occur whenever a particle’s Ggamma (energy*(G/m) becomes nearly equal to n*Qx (i.e. any integer multiplied by the horizontal betatron tune). This deliverable is why the machinery is referred to as the ''Ggamma Meter'' rather than the AGS energy meter. The Ggamma Meter takes as inputs a set of measurements of frequency (F(t)), radius (r(t)), and gauss clock counts (GCC(t)). The other energy (GgammaBr) assumes the field when the gauss clock starts counting is known. The change in field to time t is given by the measured accumulated gauss clock counts multiplied by the gauss clock calibration (gauss/GCC). In order to deal with experimental data, this calibration factor gets an added ad hoc complication, namely a correction dependent on the rate of change the counting rate. The Ggamma meter takes GCC(t) and together with the past history for this cycle calculates B(t).

43 PARTICLE ACCELERATORS↗

Scalable, Dual-Mode Occupancy Sensing for Commercial Venues

The ability to establish accurate occupancy is a key enabler for improved energy efficiency in human-occupied indoor spaces. The accurate counts can be used to adjust, in real-time, air exchange, heating, and cooling, to closely match the environmental needs of the occupants rather than to use a single setting based on maximum room occupancy. This project focuses on the use of overhead fisheye cameras and artificial intelligence (AI) algorithms as the technology to realize accurate people counting in large commercial spaces. We developed Computational Occupancy Sensing SYstem ("COSSY''), which supports large-scale deployment (thousands of square feet) and straightforward installation (using conventional power over ethernet), while providing high accuracy and low cost. COSSY has been validated at Boston University and by a third party, demonstrating people-counting accuracy of at least 89.5% in large spaces (2,000 sqft). A cost/benefit analysis performed for Boston commercial market indicates that a full payback of COSSY deployment costs due to energy savings would occur within 3-6 months from installation. Applications of COSSY reach far beyond saving energy. The precise people counting in real time could also be useful for emergency response (e.g., fire), in spatial analytics (e.g., office space management) and in some health applications (e.g., social distance assessment during pandemics).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Lawrence Livermore National Laboratory?s Book of Minimum Detectable Activity for Direct Measurement of Internally Deposited Radionuclides in Radiation Workers

Lawrence Livermore National Laboratory maintains an in vivo measurement program designed to identify and evaluate the activity of radionuclides deposited in the body. Two types of systems are primarily used for the routine monitoring of radiation workers, the lung counting system and the scanning bed whole body counting system. The lung counting system is comprised of two Canberra ACTII detector sets. Each ACTII set contains two planar germanium detectors with carbon composite end windows optimized to measure low energy photon emitting radionuclides. The ACTII detectors are placed on the upper torso over the lungs for the direct measurement of internally deposited radionuclides in the lungs that emit low energy photons. A correction for the thickness of the chest wall is applied to the efficiency. Because the thickness of the chest wall is a key factor in the measurement of low energy photon emitting radionuclides in the lung, the minimum detectable activity is a function of the chest wall thickness. The scanning bed whole body counting system is comprised of a thin air mattress on top of a carbon fiber bed that slowly scans over four high purity germanium detectors. The scanning system is designed to minimize variations in detected activity due to radionuclide distribution in the body. The scanning bed detection system is typically used for the measurement of internally deposited radionuclides that emit photons above 100 to 200 keV. MDAs have been generated for radionuclides that provide energies above 80 keV since the lowest calibration energy for the system is approximately 86 keV. The following charts and table provide best determination of minimum detectable activity using human subjects as controls for the background contributions. A wide variety of radionuclides are used throughout the laboratory and the following pages represent several of the radionuclides that have been encountered at the Whole Body and Spectroscopy Laboratories within Hazards Control.

61 RADIATION PROTECTION AND DOSIMETRY↗

Evaluation of three portable samplers for monitoring airborne fungi

Airborne fungi were monitored at five sample sites with the Burkard portable, the RCS Plus, and the SAS Super 90 air samplers; the Andersen 2-stage impactor was used for comparison. All samplers were calibrated before being used simultaneously to collect 100-liter samples at each site. The Andersen and Burkard samplers retrieved equivalent volumes of airborne fungi; the SAS Super 90 and RCS Plus measurements did not differ from each other but were significantly lower than those obtained with the Andersen or Burkard samplers. Total fungal counts correlated linearly with Cladosporium and Penicillium counts. Alternaria species, although present at all sites, did not correlate with total count or with amounts of any other fungal genera. Sampler and location significantly influenced fungal counts, but no interactions between samplers and locations were found.

NASA Center JSC↗

New method for estimating bacterial cell abundances in natural samples by use of sublimation

We have developed a new method based on the sublimation of adenine from Escherichia coli to estimate bacterial cell counts in natural samples. To demonstrate this technique, several types of natural samples, including beach sand, seawater, deep-sea sediment, and two soil samples from the Atacama Desert, were heated to a temperature of 500 degrees C for several seconds under reduced pressure. The sublimate was collected on a cold finger, and the amount of adenine released from the samples was then determined by high-performance liquid chromatography with UV absorbance detection. Based on the total amount of adenine recovered from DNA and RNA in these samples, we estimated bacterial cell counts ranging from approximately 10(5) to 10(9) E. coli cell equivalents per gram. For most of these samples, the sublimation-based cell counts were in agreement with total bacterial counts obtained by traditional DAPI (4,6-diamidino-2-phenylindole) staining.

Evaluation Studies↗

CALORIMETER-BASED ADJUSTMENT OF MULTIPLICITY DETERMINED 240PU EFF KNOWN-A ANALYSIS FOR THE ASSAY OF PLUTONIUM

In nuclear material processing facilities, it is often necessary to balance the competing demands of accuracy and throughput. While passive neutron multiplicity counting is the preferred method for relatively fast assays of plutonium, the presence of low-Z impurities (fluorine, beryllium, etc.) rapidly erodes the assay precision of passive neutron counting techniques, frequently resulting in unacceptably large total measurement uncertainties. Conversely, while calorimeters are immune to these impurity effects, the long count times required for high accuracy can be a hindrance to efficiency. The higher uncertainties in passive neutron measurements of impure material are driven by the resulting large (>>2) {alpha}-values, defined as the ({alpha},n):spontaneous fission neutron emission ratio. To counter impurity impacts for high-{alpha} materials, a known-{alpha} approach may be adopted. In this method, {alpha} is determined for a single item using a combination of gamma-ray and calorimetric measurements. Because calorimetry is based on heat output, rather than a statistical distribution of emitted neutrons, an {alpha}-value determined in this way is far more accurate than one determined from passive neutron counts. This fixed {alpha} value can be used in conventional multiplicity analysis for any plutonium-bearing item having the same chemical composition and isotopic distribution as the original. With the results of single calorimeter/passive neutron/gamma-ray measurement, these subsequent items can then be assayed with high precision and accuracy in a relatively short time, despite the presence of impurities. A calorimeter-based known-{alpha} multiplicity analysis technique is especially useful when requiring rapid, high accuracy, high precision measurements of multiple plutonium bearing items having a common source. The technique has therefore found numerous applications at the Savannah River Site. In each case, a plutonium (or mixed U/Pu) bearing item is divided into multiple containers. A single item from that batch is then selected for both neutron and calorimetric measurements; all remaining items undergo a neutron measurement only. Using the technique mentioned above, the 'true' {alpha} value determined from the first (calorimeter and passive neutron measured) item is used in multiplicity analysis for all other items in the batch. The justification for using this {alpha} value in subsequent calculations is the assumption that the chemical composition and isotopic distribution of all batch items are the same, giving a constant ({alpha},n):spontaneous fission ratio. This analysis method has been successfully applied to the KIS Facility, significantly improving measurement uncertainties and reducing processing times for numerous items. Comprehensive plans were later developed to extend the use of this method to other applications, including the K-Area Shuffler and the H-Area Pu-Blending Project. While only the feasibility study for the Shuffler has been completed, implementation of the method in the H-Area Pu-Blending Project is currently in progress and has been successfully applied to multiple items. This report serves to document the details of this method in order to serve as a reference for future applications. Also contained herein are specific examples of the application of known-{alpha} multiplicity analysis.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Uncertainty as a Function of Time for Subcritical Experiment Parameters Using the Hage-Cifarelli Formalism

When designing critical or subcritical experiments, it is desirable to have an estimate of the measurement uncertainties prior to performing an experiment. In addition, an important goal is to have the smallest measurement uncertainties possible given measurement time constraints. Having well-designed experiments with small uncertainties helps improve nuclear data and therefore has direct impacts on criticality safety. This work shows how the uncertainties in various measurement parameters vary as a function of counting time and provides an approach to estimate measured uncertainties and guides in optimizing the available counting time. The uncertainty in six parameters used in subcritical experiments was investigated as a function of time: singles count rate (R{sub 1}), doubles count rate (R{sub 2}), lifetime (1/λ), leakage multiplication (M{sub L}), spontaneous fission rate (FS), and detector efficiency (ε). A comparison to measured data will be presented at the meeting. The approach and results in this work will be used to optimize measurement time in future subcritical experiments and will be used to help estimate measurement uncertainties during the design phase. Having well-designed experiments with the smallest uncertainties possible can help the criticality safety community through data validation. (authors)

42 ENGINEERING↗

Neutrinoless double beta decay in chiral effective field theory: lepton number violation at dimension seven

Here, we analyze neutrinoless double beta decay (0νββ) within the framework of the Standard Model Effective Field Theory. Apart from the dimension-five Weinberg operator, the first contributions appear at dimension seven. We classify the operators and evolve them to the electroweak scale, where we match them to effective dimension-six, -seven, and -nine operators. In the next step, after renormalization group evolution to the QCD scale, we construct the chiral Lagrangian arising from these operators. We then develop a power-counting scheme and derive the two-nucleon 0νββ currents up to leading order in the power counting for each lepton-number-violating operator. We argue that the leading-order contribution to the decay rate depends on a relatively small number of nuclear matrix elements. We test our power counting by comparing nuclear matrix elements obtained by various methods and by different groups. We find that the power counting works well for nuclear matrix elements calculated from a specific method, while, as in the case of light Majorana neutrino exchange, the overall magnitude of the matrix elements can differ by factors of two to three between methods. We also calculate the constraints that can be set on dimension-seven lepton-number-violating operators from 0νββ experiments and study the interplay between dimension-five and -seven operators, discussing how dimension-seven contributions affect the interpretation of 0νββ in terms of the effective Majorana mass m ββ .

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Discriminating Nuclear Threats from Benign Sources in Gamma-ray Spectra using a Spectral Comparison Ratio Method

This manuscript presents a method for categorizing gamma-ray spectra as benign or threatening. It is widely believed that the goal of segregating gamma-ray spectra into benign and threatening populations can achieved with fewer counts than are required for confident characterization of a spectrum’s isotopic composition, while still providing improvement over count-based algorithms. This has potentially important implications on the detection of radiological and nuclear threats, where decisions must be made from analysis of count-starved spectra that dominate the landscape of monitoring special nuclear material transport and lost-or-stolen source search. We report here the method of Spectral Comparison Ratios (SCRs) which is useful in the targeted detection of specific gamma-ray signatures or signature classes. SCRs discriminate between benign and target sources by comparing counts in broad, pre-defined energy bins that are pre-determined using statistical discrimination criteria. The integral component of the SCR algorithm is the location and interdependence of the energy bins, and we discuss the statistical methods used for choosing their locations along with the decision criteria that maximally separate targets from benign sources.

algorithm development↗

Arterial inflammation in young patients with human immunodeficiency virus infection: A cross-sectional study using F-18 FDG PET/CT

Background: HIV infection is associated with the risk of development of atherosclerosis at a younger age. We compared arterial inflammation in HIV-infected and HIV-uninfected patients with otherwise low-risk factors for cardiovascular disease (CVD) using FDG PET/CT. Methods: 242 patients aged 18–40 years with low-risk factors for CVD consisting of 121 HIV-infected patients and 121 HIV-uninfected age- and gender-matched controls were studied, mean age = 34.95 ± 5.46 years. We calculated and compared the target-to-background ratio of FDG uptake in ascending aorta of HIV-infected and non-infected patients. Results: Median CD4 count and viral load were 375.5 cells/mm{sup 3} (range 2-1094) and 6391.00 copies/mL (range 24-1,348,622), respectively. There was slightly higher but significant overlap in the TBR between HIV-infected group compared with control (1.22, 0.87-2.02 vs. 1.12, 0.38-1.40, P < 0.001). TBR was neither affected by CD4 count levels nor the presence or absence of detectable viremia. We also found no significant difference in TBR between male and female patients with HIV infection. We found a weak positive correlation between TBR and CD4 count, TBR and duration of HIV infection, and a very weak negative correlation between TBR and viral load. There was no significant difference in TBR between patients on HAART and those not yet commenced on therapy. Conclusion: Marginally higher TBR with a significant overlap exist in HIV-infected patients compared with control. Arterial F-18 FDG uptake is not affected by the CD 4 count, viral load, gender, or duration of HIV infection.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prediction of Mass Spectral Response Factors from Predicted Chemometric Data for Druglike Molecules

A method is developed for the prediction of mass spectral ion counts of drug-like molecules using in silico calculated chemometric data. Various chemometric data, including polar and molecular surface areas, aqueous solvation free energies, and gas-phase and aqueous proton affinities were computed, and a statistically significant relationship between measured mass spectral ion counts and the combination of aqueous proton affinity and total molecular surface area was identified. In particular, through multilinear regression of ion counts on predicted chemometric data, we find that log{sub 10}(MS ion counts) = –4.824 + c{sub 1}•PA + c{sub 2}•SA, where PA is the aqueous proton affinity of the molecule computed at the SMD(aq)/M06-L/MIDI!//M06-L/MIDI! level of electronic structure theory, SA is the total surface area of the molecule in its conjugate base form, and c{sub 1} and c{sub 2} have values of –3.912 × 10{sup –2} mol kcal{sup –1} and 3.682 × 10{sup –3} Å{sup –2}. On a 66-molecule training set, this regression exhibits a multiple R value of 0.791 with p values for the intercept, c{sub 1}, and c{sub 2} of 1.4 × 10{sup –3}, 4.3 × 10{sup –10}, and 2.5 × 10{sup –6}, respectively. Application of this regression to an 11-molecule test set provides a good correlation of prediction with experiment (R = 0.905) albeit with a systematic underestimation of about 0.2 log units. This method may prove useful for semiquantitative analysis of drug metabolites for which MS response factors or authentic standards are not readily available. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Benchmarking the repeatability of a pneumatic cyclic neutron activation analysis facility using 16 O(n,p) 16 N for nuclear forensics

A target was prepared for cyclic neutron activation analysis by heat sealing lithium-carbonate in polyethylene. The target was cyclically irradiated 50 times using a Thermo-Scientific accelerator based deuterium–tritium fusion neutron generator. During counting periods, gamma-rays emitted by 16 N were detected using three high-purity germanium detectors acquiring data in list-mode. Total counts acquired in each spectrum were compared between the three detectors to examine variability in geometric positioning of the target and variability of the generator intensity throughout the experiment. These two effects were determined to be the primary sources of variation in the measured counts. Variation in target positioning and generator intensity were found to increase the standard deviation by 34% and 33%, respectively. Transit times to the detector were found to be slower and more variable than transit to the generator but were well below the half second threshold needed to measure short-lived radionuclides with half-lives on the order of seconds. The standard deviation in irradiation time was found to be less than 1 milliseconds. The impact on statistical variability in the measured counts was negligible relative to the two primary sources of variation. Spectra acquired from each cycle were summed together. The sum of the peak areas from the 6.1 MeV gamma-ray and its corresponding single and double escape peaks were used to measure the half-life of 16N. The result of 7.108(15) seconds derived from data suggests that the currently published value of 7.13(2) seconds has minimal systematic bias induced by background.

43 PARTICLE ACCELERATORS↗

Carbon fiber design improvements based on economic models

Circular fiber geometries are predominant in commercial carbon fiber material systems, but the use of this fiber shape has numerous limitations. Circular geometries have continuous symmetry, which is helpful for various processing considerations, but also have the largest possible maximum diffusion thickness for a given fiber area. This characteristic means that circular carbon fibers always have the highest material processing cost and lowest production throughput compared to any other fiber shape with the same area and tow count. To quantify material cost and other benefits for non-circular carbon fiber geometries, process models for polyacrylonitrile based carbon fiber production are developed in relationship to the carbon fiber shape, size, and tow count. For a given fiber shape, precursor production costs are shown to favor maximizing fiber size while conversion costs are minimized by the smallest fiber size. These competing cost trends result in a numerically optimal fiber size for a given shape and tow count, while both cost components are decreased by increasing tow count. Cost–performance tradeoffs for three lobe fiber geometries are studied by supplementing the cost trends with a numerical failure model to predict compressive strength for discrete shape variants. The shape selection is shown to be more sensitive to variations in cost than compressive strength while suboptimal shape designs can improve manufacturing robustness and achievable fiber volume fractions. Finally, an optimal three lobe carbon fiber is identified that balances the set of considerations while reducing costs and embodied energy and increasing production throughput compared to a commercial carbon fiber.

Carbon fiber↗

Hypertension and hematologic parameters in a community near a uranium processing facility

Background: Environmental uranium exposure originating as a byproduct of uranium processing can impact human health. The Fernald Feed Materials Production Center functioned as a uranium processing facility from 1951 to 1989, and potential health effects among residents living near this plant were investigated via the Fernald Medical Monitoring Program (FMMP). Methods: Data from 8216 adult FMMP participants were used to test the hypothesis that elevated uranium exposure was associated with indicators of hypertension or changes in hematologic parameters at entry into the program. A cumulative uranium exposure estimate, developed by FMMP investigators, was used to classify exposure. Systolic and diastolic blood pressure and physician diagnoses were used to assess hypertension; and red blood cells, platelets, and white blood cell differential counts were used to characterize hematology. The relationship between uranium exposure and hypertension or hematologic parameters was evaluated using generalized linear models and quantile regression for continuous outcomes, and logistic regression or ordinal logistic regression for categorical outcomes, after adjustment for potential confounding factors. Results: Of 8216 adult FMMP participants 4187 (51%) had low cumulative uranium exposure, 1273 (15%) had moderate exposure, and 2756 (34%) were in the high (>0.50 Sievert) cumulative lifetime uranium exposure category. Participants with elevated uranium exposure had decreased white blood cell and lymphocyte counts and increased eosinophil counts. Female participants with higher uranium exposures had elevated systolic blood pressure compared to women with lower exposures. However, no exposure-related changes were observed in diastolic blood pressure or hypertension diagnoses among female or male participants. Conclusions: Results from this investigation suggest that residents in the vicinity of the Fernald plant with elevated exposure to uranium primarily via inhalation exhibited decreases in white blood cell counts, and small, though statistically significant, gender-specific alterations in systolic blood pressure at entry into the FMMP.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Fat Composition Changes in Bone Marrow During Chemotherapy and Radiation Therapy

Purpose: To quantify changes in bone marrow fat fraction and determine associations with peripheral blood cell counts. Methods and Materials: In this prospective study, 19 patients received either highly myelotoxic treatment (radiation therapy plus cisplatin, 5-fluorouracil mitomycin C [FU/MMC], or cisplatin/5-FU/cetuximab) or less myelotoxic treatment (capecitabine-radiation therapy or no concurrent chemotherapy). Patients underwent MR imaging and venipuncture at baseline, midtreatment, and posttreatment visits. We performed mixed effects modeling of the mean proton density fat fraction (PDFF[%]) by linear time, treatment, and vertebral column region (lumbar [L]4-sacral [S]2 vs thoracic [T]10-L3 vs cervical[C]3-T9), while controlling for cumulative mean dose and other confounders. Spearman rank correlations were performed by white blood cell (WBC) counts versus the differences in PDFF(%) before and after treatment. Results: Cumulative mean dose was associated with a 0.43% per Gy (P=.004) increase in PDFF(%). In the highly myelotoxic group, we observed significant changes in PDFF(%) per visit within L4-S2 (10.1%, P<.001) and within T10-L3 (3.93%, P=.01), relative to the reference C3-T9. In the less myelotoxic group, we did not observe significant changes in PDFF(%) per visit according to region. Within L4-S2, we observed a significant difference between treatment groups in the change in PDFF(%) per visit (5.36%, P=.04). Rank correlations of the inverse log differences in WBC versus the differences in PDFF(%) overall and within T10-S2 ranged from 0.69 to 0.78 (P<.05). Rank correlations of the inverse log differences in absolute neutrophil counts versus the differences in PDFF(%) overall and within L4-S2 ranged from 0.79 to 0.81 (P<.05). Conclusions: Magnetic resonance imaging fat quantification is sensitive to marrow composition changes that result from chemoradiation therapy. These changes are associated with peripheral blood cell counts. This study supports a rationale for bone marrow-sparing treatment planning to reduce the risk of hematologic toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗