Search NASA⌕ Search

SEARCH · Search NASA

Results for “Data reduction methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

Advanced modeling and simulation of research reactors using dynamic mode decomposition

Full text of publication follows. Due to the ever-increasing safety requirements, the current trend of nuclear reactor analysis is shifting towards high-fidelity multi-physics models, which have a very high computational cost and modelling complexity. As the cost of even a single model run makes it impossible to analyse the behaviour and performance of these models on large-scale commercial plants, it has become even more significant to provide suitable benchmarks to validate and test them extensively. In this sense, research reactors offer a promising solution for the initial validation of high-fidelity models, as they are significantly smaller than commercial reactors and their characteristics are well known. In particular, the reactors of the TRIGA family have been used to assess and validate models and methods for Generation-IV designs, as they have some similar features (such as the dominance of natural convection as cooling mechanism and the difficulties in performing sub-channel analysis using standard codes). Still, the computational requirements of high-fidelity models make them unsuitable for real-time analysis, even following their assessment on research reactors. In this sense, Model Order Reduction (MOR) techniques give an additional strategy to reduce the computational cost of high-fidelity models (whilst preserving sufficient accuracy). In particular, this work focuses on Dynamic Mode Decomposition (DMD), a non-intrusive MOR technique that aims at representing models with explicit temporal dynamics by extracting the time-varying characteristics and the governing structures based only on a set of available data, thus without needing any underlying knowledge of the governing equations. In addition, DMD also computes a low-dimensional surrogate of the dynamic matrix of the system, making it suited for stability analysis and real-time evaluations. This work focuses on the application and validation of the DMD method on the Computational Fluid-Dynamics (CFD) model TRIGA Mark II reactor, also discussing in detail the potentiality of this algorithm as an advanced modelling tool for nuclear reactor analysis. (author)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Contemporary Trends in the Acid-Base Status of the Two Acid-Sensitive Streams in Western Maryland

Recovery of streamwater acid neutralizing capacity (ANC) resulting from declines in regional acid deposition was examined using contemporary (1990-2005) data from two long-term monitoring stations located on the Appalachian Plateau in western Maryland, U.S. Two computational methods were used to estimate daily, monthly, and annual fluxes and discharge-weighted concentrations of ANC, sulfate, nitrate, and base cations over the period of record, and two statistical methods were used to evaluate long-term trends in fluxes and concentrations. The methods used to estimate concentrations, as well as the, statistical techniques, produced very similar results, underlining the robustness of the identified trends. We found clear evidence that streamwater sulfate concentrations have declined at an average rate of about 3 (microns)eq L(exp -1) yr(exp -1) at the two sites due to a 34% reduction in wet atmospheric sulfur deposition. Trends in nitrate concentrations appear to be related to other watershed factors, especially forest disturbance. The best evidence of recovery is based on a doubling of ANC (from 21 to 42 (microns)eq L(exp -1) at the more acid-sensitive site over the 16-year period. A slowing, or possible reversal, in the sulfate, nitrate, and SBC trends is evident in our data and may portend a decline in the rate of--or end to--further recovery.

Eshleman, Keith N.↗

Proposal for a Vehicle Level Test Procedure to Measure Air Conditioning Fuel Use

The air-conditioning (A/C) compressor load significantly impacts the fuel economy of conventional vehicles and the fuel use/range of plug-in hybrid electric vehicles (PHEV). A National Renewable Energy Laboratory (NREL) vehicle performance analysis shows the operation of the air conditioner reduces the charge depletion range of a 40-mile range PHEV from 18% to 30% in a worst case hot environment. Designing for air conditioning electrical loads impacts PHEV and electric vehicle (EV) energy storage system size and cost. While automobile manufacturers have climate control procedures to assess A/C performance, and the U.S. EPA has the SCO3 drive cycle to measure indirect A/C emissions, there is no automotive industry consensus on a vehicle level A/C fuel use test procedure. With increasing attention on A/C fuel use due to increased regulatory activities and the development of PHEVs and EVs, a test procedure is needed to accurately assess the impact of climate control loads. A vehicle thermal soak period is recommended, with solar lamps that meet the SCO3 requirements or an alternative heating method such as portable electric heaters. After soaking, the vehicle is operated over repeated drive cycles or at a constant speed until steady-state cabin air temperature is attained. With this method, the cooldown and steady-state A/C fuel use are measured. This method can be run at either different ambient temperatures to provide data for the GREEN-MAC-LCCP model temperature bins or at a single representative ambient temperature. Vehicles with automatic climate systems are allowed to control as designed, while vehicles with manual climate systems are adjusted to approximate expected climate control settings. An A/C off test is also run for all drive profiles. This procedure measures approximate real-world A/C fuel use and assess the impact of thermal load reduction strategies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Group Projected subspace pursuit for IDENTification of variable coefficient differential equations (GP-IDENT)

We propose an effective and robust algorithm for identifying partial differential equations (PDEs) with space-time varying coefficients from the noisy observation of a single solution trajectory. Identifying unknown differential equations from noisy data is a difficult task, and it is even more challenging with space and time varying coefficients in the PDE. The proposed algorithm, GP-IDENT, has three ingredients: (i) we use B-spline bases to express the unknown space and time varying coefficients, (ii) we propose Group Projected Subspace Pursuit (GPSP) to find a sequence of candidate PDEs with various levels of complexity, and (iii) we propose a new criterion for model selection using the Reduction in Residual (RR) to choose an optimal one among a pool of candidates. The new GPSP considers group projected subspaces which is more robust than existing methods in distinguishing correlated group features. We test GP-IDENT on a variety of PDEs and PDE systems, and compare it with the state-of-the-art parametric PDE identification algorithms under different settings to illustrate its outstanding performance. Furthermore, our experiments show that GP-IDENT is effective in identifying the correct terms from a large dictionary, and our model selection scheme is robust to noise.

Data-driven method↗

Real-time microstructure imaging by Laue microdiffraction: A sample application in laser 3D printed Ni-based superalloys

Synchrotron-based Laue microdiffraction has been widely applied to characterize the local crystal structure, orientation, and defects of inhomogeneous polycrystalline solids by raster scanning them under a micro/nano focused polychromatic X-ray probe. In a typical experiment, a large number of Laue diffraction patterns are collected, requiring novel data reduction and analysis approaches, especially for researchers who do not have access to fast parallel computing capabilities. In this article, a novel approach is developed by plotting the distributions of the average recorded intensity and the average filtered intensity of the Laue patterns. Visualization of the characteristic microstructural features is realized in real time during data collection. As an example, this method is applied to image key features such as microcracks, carbides, heat affected zone, and dendrites in a laser assisted 3D printed Ni-based superalloy, at a speed much faster than data collection. Such analytical approach remains valid for a wide range of crystalline solids, and therefore extends the application range of the Laue microdiffraction technique to problems where real-time decision-making during experiment is crucial (for instance time-resolved non-reversible experiments).

36 MATERIALS SCIENCE↗

Electromagnetically induced transparency in an open V-type molecular system

We report the experimental observation of electromagnetically induced transparency (EIT) in an inhomogeneously broadened V-type Na{sub 2} molecular system. The experiment is performed with both co- and counterpropagating arrangements for the propagation directions of the coupling and probe laser beams. In our theoretical model we employ the density matrix formalism, as well as perturbative methods for obtaining the probe field absorption profile for both open and closed systems. Simulations of the experimental data show excellent agreement with the predictions derived from the basic theory. Our fluorescent intensity measurements show that, in the copropagating configuration, the EIT plus saturation window depth is about 95%, while under similar conditions in the counterpropagating geometry we observed 40%-45% reduction in the fluorescence signal around the line center. To separate the two simultaneously occurring mechanisms in a V-type system (i.e., EIT and saturation) that are induced by the coupling field, we have carried out theoretical calculations which show that, in the copropagating case, a significant fraction of the depth of the dip is due to the coherent effect of EIT. When the coupling and probe beams are in the counterpropagating configuration, the dip is mostly due to saturation effects alone.

74 ATOMIC AND MOLECULAR PHYSICS↗

A method for patient dose reduction in dynamic contrast enhanced CT study

Purpose: In dynamic contrast enhanced CT (DCE-CT) study, prolonged CT scanning with high temporal resolution is required to give accurate and precise estimates of kinetic parameters. However, such scanning protocol could lead to substantial radiation dose to the patient. A novel method is proposed to reduce radiation dose to patient, while maintaining high accuracy for kinetic parameter estimates in DCE-CT study. Methods: The method is based on a previous investigation that the arterial impulse response (AIR) in DCE-CT study can be predicted using a population-based scheme. In the proposed method, DCE-CT scanning is performed with relatively low temporal resolution, hence, giving rise to reduction in patient dose. A novel method is proposed to estimate the arterial input function (AIF) based on the coarsely sampled AIF. By using the estimated AIF in the tracer kinetic analysis of the coarsely sampled DCE-CT study, the calculated kinetic parameters are able to achieve a high degree of accuracy. The method was tested on a DCE-CT data set of 48 patients with cervical cancer scanned at high temporal resolution. A random cohort of 34 patients was chosen to construct the orthonormal bases of the AIRs via singular value decomposition method. The determined set of orthonormal bases was used to fit the AIFs in the second cohort (14 patients) at varying levels of down sampling. For each dataset in the second cohort, the estimated AIF was used for kinetic analyses of the modified Tofts and adiabatic tissue homogeneity models for each of the down-sampling schemes between intervals from 2 to 15 s. The results were compared with analyses done with the ''raw'' down-sampled AIF. Results: In the first group of 34 patients, there were 11 orthonormal bases identified to describe the AIRs. The AIFs in the second group were estimated in high accuracy based on the 11 orthonormal bases established in the first group along with down-sampled AIFs. Using the 11 orthonormal bases, the estimated AIFs for the second group were found to have an averaged maximal percentage error of 3.4%{+-} 7.5% in all sampling schemes up to 15 s. The results of kinetic analysis with the proposed method compared with down sampling alone showed that the proposed method is superior in maintaining the accuracy in volume transfer constant (K{sup trans} ) after 9 s down-sampling interval, blood volume (v{sub b} ) for almost all down-sampling intervals, and blood flow (F) after 11 s down-sampling interval. The preliminary results suggested that the proposed method is able to support scanning intervals of 10-15 s at a cost of 6.2%-10.0% loss in accuracy of K{sup trans} and 10.9%-19.4% in v{sub b}, and the scanning intervals of 12-15 s at a cost of 9.7%-14.6% for F in DEC-CT studies for patients with cervix cancer. Conclusions: The proposed method of AIF estimation allows low scanning frequency in DCE-CT study to reduce radiation dose to patient, while maintaining relatively high accuracy in the kinetic parameter estimates. The initial results suggested that the method is applicable for DCE-CT studies for patients with cervical cancer.

60 APPLIED LIFE SCIENCES↗

Active Subspaces for Wind Plant Surrogate Modeling

Understanding the uncertainty in wind plant performance is crucial to their cost-effective design and operation. However, conventional approaches to uncertainty quantification (UQ), such as Monte Carlo techniques or surrogate modeling, are often computationally intractable for utility-scale wind plants because of poor congergence rates or the curse of dimensionality. In this paper we demonstrate that wind plant power uncertainty can be well represented with a low-dimensional active subspace, thereby achieving a significant reduction in the dimension of the surrogate modeling problem. We apply the active sub-spaces technique to UQ of plant power output with respect to uncertainty in turbine axial induction factors, and find a single active subspace direction dominates the sensitivity in power output. When this single active subspace direction is used to construct a quadratic surrogate model, the number of model unknowns can be reduced by up to 3 orders of magnitude without compromising performance on unseen test data. We conclude that the dimension reduction achieved with active subspaces makes surrogate-based UQ approaches tractable for utility-scale wind plants.

17 WIND ENERGY↗

Trace-element analysis of 1000 environmental samples per year using instrumental neutron activation analysis

The technology and methods developed at the Plum Brook Reactor to analyze 1000 samples per year and report data on as many as 56 elements are described. The manpower for the complete analysis of 20 to 24 samples per week required only 3 to 3.5 hours per sample. The solutions to problems encountered in sample preparation, irradiation, and counting are discussed. The automation of data reduction is described. Typical data on various sample matrices are presented.

Sheibley, D. W.↗

Performance Enhancement of the RatCAP Awake Rate Brain PET System

The first full prototype of the RatCAP PET system, designed to image the brain of a rat while conscious, has been completed. Initial results demonstrated excellent spatial resolution, 1.8 mm FWHM with filtered backprojection and <1.5 mm FWHM with a Monte Carlo based MLEM method. However, noise equivalent countrate studies indicated the need for better timing to mitigate the effect of randoms. Thus, the front-end ASIC has been redesigned to minimize time walk, an accurate coincidence time alignment method has been implemented, and a variance reduction technique for the randoms is being developed. To maximize the quantitative capabilities required for neuroscience, corrections are being implemented and validated for positron range and photon noncollinearity, scatter (including outside the field of view), attenuation, randoms, and detector efficiency (deadtime is negligible). In addition, a more robust and compact PCI-based optical data acquisition system has been built to replace the original VME-based system while retaining the linux-based data processing and image reconstruction codes. Finally, a number of new animal imaging experiments have been carried out to demonstrate the performance of the RatCAP in real imaging situations, including an F-18 fluoride bone scan, a C-11 raclopride scan, and a dynamic C-11 methamphetamine scan.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Kinematic Variables and Feature Engineering for Particle Phenomenology

Kinematic variables have been playing an important role in collider phenomenology, as they expedite discoveries of new particles by separating signal events from unwanted background events and allow for measurements of particle properties such as masses, couplings, spins, etc. For the past 10 years, an enormous number of kinematic variables have been designed and proposed, primarily for the experiments at the Large Hadron Collider, allowing for a drastic reduction of high-dimensional experimental data to lower-dimensional observables, from which one can readily extract underlying features of phase space and develop better-optimized data-analysis strategies. We review these recent developments in the area of phase space kinematics, summarizing the new kinematic variables with important phenomenological implications and physics applications. We also review recently proposed analysis methods and techniques specifically designed to leverage the new kinematic variables. As machine learning is nowadays percolating through many fields of particle physics including collider phenomenology, we discuss the interconnection and mutual complementarity of kinematic variables and machine learning techniques. We finally discuss how the utilization of kinematic variables originally developed for colliders can be extended to other high-energy physics experiments including neutrino experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Structural and magnetic properties of La{sub 1−x}Ce{sub x}Fe{sub 1−x}Cr{sub x}O{sub 3} orthoferrite prepared by co-precipitation method

Graphical abstract: TEM micrographs of La{sub 1−x}Ce{sub x}Fe{sub 1−x}Cr{sub x}O{sub 3} for x = 0.0. - Highlights: • The composition of La{sub 1−x}Ce{sub x}Fe{sub 1−x} Cr{sub x}O{sub 3} was prepared by co-precipitation method. • X-ray diffraction showed orthorhombic structure with space group Pnma. • With increasing Ce and Cr content, a decrease of the unit cell volume. • Enhancement in the coercivity (H{sub c}) with increasing Ce and Cr content. • Reduction of M{sub s} and M{sub r} up to x = 0.15 and increases with further increases of x. - Abstract: Nanocrystalline orthoferrites with the composition of La{sub 1−x}Ce{sub x}Fe{sub 1−x} Cr{sub x}O{sub 3} where (x = 0, 0.1, 0.15 and 0.2) were prepared by co-precipitation method. The structural and magnetic properties of the La{sub 1−x}Ce{sub x}Fe{sub 1−x}Cr{sub x}O{sub 3} system have been investigated. X-ray diffraction showed the formation of orthorhombic structure with space group Pnma for different compositions. With increasing Ce and Cr content, lattice parameters a and c were found to decrease while b increases, resulting in a decrease of the unit cell volume. The crystallite size was calculated from XRD data and compared with that obtained from TEM micrographs. Vibrating sample magnetometer measurements reveal an enhancement in the coercivity (H{sub c}) with increasing Ce and Cr content and reduction of saturation magnetization (M{sub s}) and remnant magnetization (M{sub r}) up to x = 0.15 and increases with further increases of x. The magnetic susceptibility measurements vs. temperature showed canted-antiferromagnetic (AFM) in which the Neel temperature is increasing with Ce and Cr content.

36 MATERIALS SCIENCE↗

TH-E-18A-01: Developments in Monte Carlo Methods for Medical Imaging

Monte Carlo simulation methods are widely used in medical physics research and are starting to be implemented in clinical applications such as radiation therapy planning systems. Monte Carlo simulations offer the capability to accurately estimate quantities of interest that are challenging to measure experimentally while taking into account the realistic anatomy of an individual patient. Traditionally, practical application of Monte Carlo simulation codes in diagnostic imaging was limited by the need for large computational resources or long execution times. However, recent advancements in high-performance computing hardware, combined with a new generation of Monte Carlo simulation algorithms and novel postprocessing methods, are allowing for the computation of relevant imaging parameters of interest such as patient organ doses and scatter-to-primaryratios in radiographic projections in just a few seconds using affordable computational resources. Programmable Graphics Processing Units (GPUs), for example, provide a convenient, affordable platform for parallelized Monte Carlo executions that yield simulation times on the order of 10{sup 7} xray/ s. Even with GPU acceleration, however, Monte Carlo simulation times can be prohibitive for routine clinical practice. To reduce simulation times further, variance reduction techniques can be used to alter the probabilistic models underlying the x-ray tracking process, resulting in lower variance in the results without biasing the estimates. Other complementary strategies for further reductions in computation time are denoising of the Monte Carlo estimates and estimating (scoring) the quantity of interest at a sparse set of sampling locations (e.g. at a small number of detector pixels in a scatter simulation) followed by interpolation. Beyond reduction of the computational resources required for performing Monte Carlo simulations in medical imaging, the use of accurate representations of patient anatomy is crucial to the virtual generation of medical images and accurate estimation of radiation dose and other imaging parameters. For this, detailed computational phantoms of the patient anatomy must be utilized and implemented within the radiation transport code. Computational phantoms presently come in one of three format types, and in one of four morphometric categories. Format types include stylized (mathematical equation-based), voxel (segmented CT/MR images), and hybrid (NURBS and polygon mesh surfaces). Morphometric categories include reference (small library of phantoms by age at 50th height/weight percentile), patient-dependent (larger library of phantoms at various combinations of height/weight percentiles), patient-sculpted (phantoms altered to match the patient's unique outer body contour), and finally, patient-specific (an exact representation of the patient with respect to both body contour and internal anatomy). The existence and availability of these phantoms represents a very important advance for the simulation of realistic medical imaging applications using Monte Carlo methods. New Monte Carlo simulation codes need to be thoroughly validated before they can be used to perform novel research. Ideally, the validation process would involve comparison of results with those of an experimental measurement, but accurate replication of experimental conditions can be very challenging. It is very common to validate new Monte Carlo simulations by replicating previously published simulation results of similar experiments. This process, however, is commonly problematic due to the lack of sufficient information in the published reports of previous work so as to be able to replicate the simulation in detail. To aid in this process, the AAPM Task Group 195 prepared a report in which six different imaging research experiments commonly performed using Monte Carlo simulations are described and their results provided. The simulation conditions of all six cases are provided in full detail, with all necessary data on material composition, source, geometry, scoring and other parameters provided. The results of these simulations when performed with the four most common publicly available Monte Carlo packages are also provided in tabular form. The Task Group 195 Report will be useful for researchers needing to validate their Monte Carlo work, and for trainees needing to learn Monte Carlo simulation methods. In this symposium we will review the recent advancements in highperformance computing hardware enabling the reduction in computational resources needed for Monte Carlo simulations in medical imaging. We will review variance reduction techniques commonly applied in Monte Carlo simulations of medical imaging systems and present implementation strategies for efficient combination of these techniques with GPU acceleration. Trade-offs involved in Monte Carlo acceleration by means of denoising and “sparse sampling” will be discussed. A method for rapid scatter correction in cone-beam CT (<5 min/scan) will be presented as an illustration of the simulation speeds achievable with optimized Monte Carlo simulations. We will also discuss the development, availability, and capability of the various combinations of computational phantoms for Monte Carlo simulation of medical imaging systems. Finally, we will review some examples of experimental validation of Monte Carlo simulations and will present the AAPM Task Group 195 Report. Learning Objectives: Describe the advances in hardware available for performing Monte Carlo simulations in high performance computing environments. Explain variance reduction, denoising and sparse sampling techniques available for reduction of computational time needed for Monte Carlo simulations of medical imaging. List and compare the computational anthropomorphic phantoms currently available for more accurate assessment of medical imaging parameters in Monte Carlo simulations. Describe experimental methods used for validation of Monte Carlo simulations in medical imaging. Describe the AAPM Task Group 195 Report and its use for validation and teaching of Monte Carlo simulations in medical imaging.

60 APPLIED LIFE SCIENCES↗

Isolating Detrital and Diagenetic Signals in Magnetic Susceptibility Records From Methane‐Bearing Marine Sediments

Abstract Volume‐dependent magnetic susceptibility (κ) is commonly used for paleoenvironmental reconstructions in both terrestrial and marine sedimentary environments where it reflects a mixed signal between primary deposition and secondary diagenesis. In the marine environment, κ is strongly influenced by the abundance of ferrimagnetic minerals regulated by sediment transport processes. Post‐depositional alteration by H 2 S, however, can dissolve titanomagnetite, releasing reactive Fe that promotes pyritization and subsequently decreases κ. Here, we provide a new approach for isolating the detrital signal in κ and identifying intervals of diagenetic alteration of κ driven by organoclastic sulfate reduction (OSR) and the anaerobic oxidation of methane (AOM) in methane‐bearing marine sediments offshore India. Using the correlation of a heavy mineral proxy from X‐ray fluorescence data (Zr/Rb) and κ in unaltered sediments, we predict the primary detrital κ signal and identify intervals of decreased κ, which correspond to increased total sulfur content. Our approach is a rapid, high‐resolution method that can identify overprinted κ resulting from pyritization of titanomagnetite due to H 2 S production in marine sediments. In addition, total organic carbon, total sulfur, and authigenic carbonate δ 13 C measurements indicate that both OSR and AOM can drive the observed κ loss, but AOM drives the greatest decreases in κ. Overall, our approach can enhance paleoenvironmental reconstructions and provide insight into paleo‐positions of the sulfate‐methane transition zone, past enhancements of OSR or paleo‐methane seepage, and the role of detrital iron oxide minerals on the marine sediment sulfur sink, with consequences influencing the development of chemosynthetic biological communities at methane seeps.

58 GEOSCIENCES↗

THE RELATIVE INTENSITY CALIBRATION OF HINODE/EIS AND SOHO/SUMER

In this work, we have used simultaneous observations of the quiet Sun above the solar west limb obtained with the Hinode/Extreme ultraviolet Imaging Spectrograph and SOHO/SUMER instruments to determine their relative intensity calibration. We used two different methods: intensity ratios of lines emitted by the same upper level and observed in the spectral ranges of the two spectrometers, and the determination of the differential emission measure and total emission measure of the plasma. We review the uncertainties in our analysis and conclude that the relative calibration of the two instruments, as it can be determined from the standard data reduction software of each of them, is correct within uncertainties.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Forecasting constraints on the mean free path of ionizing photons at z ≥ 5.4 from the Lyman-α forest flux autocorrelation function

ABSTRACT Fluctuations in Lyman-α (Ly α) forest transmission towards high-z quasars are partially sourced from spatial fluctuations in the ultraviolet background, the level of which are set by the mean free path of ionizing photons (λmfp). The autocorrelation function of Ly α forest flux characterizes the strength and scale of transmission fluctuations and, as we show, is thus sensitive to λmfp. Recent measurements at z ∼ 6 suggest a rapid evolution of λmfp at z > 5.0 which would leave a signature in the evolution of the autocorrelation function. For this forecast, we model mock Ly α forest data with properties similar to the XQR-30 extended data set at 5.4 ≤ z ≤ 6.0. At each z, we investigate 100 mock data sets and an ideal case where mock data matches model values of the autocorrelation function. For ideal data with λmfp = 9.0 cMpc at z = 6.0, we recover $\lambda _{\text{mfp}}=12^{+6}_{-3}$ cMpc. This precision is comparable to direct measurements of λmfp from the stacking of quasar spectra beyond the Lyman limit. Hypothetical high-resolution data leads to a $\sim 40~{{\ \rm per\ cent}}$ reduction in the error bars over all z. The distribution of mock values of the autocorrelation function in this work is highly non-Gaussian for high-z, which should caution work with other statistics of the high-z Ly α forest against making this assumption. We use a rigorous statistical method to pass an inference test, however future work on non-Gaussian methods will enable higher precision measurements.

Astronomy & Astrophysics↗

Spatiotemporally Adaptive Compression for Scientific Dataset with Feature Preservation – A Case Study on Simulation Data with Extreme Climate Events Analysis

Scientific discoveries are increasingly constrained by limited storage space and I/O capacities. For time-series simulations and experiments, their data often need to be decimated over timesteps to accommodate storage and I/O limitations. In this paper, we propose a technique that addresses storage costs while improving post-analysis accuracy through spatiotemporal adaptive, error-controlled lossy compression. We investigate the trade-off between data precision and temporal output rates, revealing that reducing data precision and increasing timestep frequency lead to more accurate analysis outcomes. Additionally, we integrate spatiotemporal feature detection with data compression and demonstrate that performing adaptive error-bounded compression in higher dimensional space enables greater compression ratios, leveraging the error propagation theory of a transformation-based compressor. To evaluate our approach, we conduct experiments using the well-known E3SM climate simulation code and apply our method to compress variables used for cyclone tracking. Our results show a significant reduction in storage size while enhancing the quality of cyclone tracking analysis, both quantitatively and qualitatively, in comparison to the prevalent timestep decimation approach. Compared to three state-of-the-art lossy compressors lacking feature preservation capabilities, our adaptive compression framework improves perfectly matched cases in TC tracking by 26.4-51.3% at medium compression ratios and by 77.3-571.1% at large compression ratios, with a merely 5–11% computational overhead.

Gong, Qian↗

Wearable Sensors Measure Ankle Joint Changes of Patients with Parkinson’s Disease before and after Acute Levodopa Challenge

Background . Previous studies found levodopa could improve the activity of the ankle joints of patients with Parkinson’s disease (PD). But ankle joint movement is composed of four motion ranges. The specific changes of four motion ranges in PD remain unknown. Objective . The purpose of this study was to decompose the complex ankle joint movement, measure ankle joint changes before and after the acute levodopa challenge test (ALCT), and investigate the effects of these parameters on gait performance. Methods . 29 PD patients and 30 healthy control subjects (HC) completed the Instrumented Stand and Walk (ISAW) test and gait parameters were collected by the JiBuEn gait analysis system. The percentage of improvement of gait data and the UPDRS III in the on-drug condition (ON) were determined with respect to the off-drug condition (OFF). Results . We observed a reduction in the heel strike angle (HS), 3-plantarflexion (3-PF) angle, and 4-dorsiflexion (4-DF) angle of ankle joints. We did not find significant difference in the toe-off angle (TO), 1-plantarflexion (1-PF) angle, and 2-dorsiflexion (2-DF) angle among three groups. Stride length improvement rate was significantly correlated with HS ( r s = 0.616, P < 0.001 ) and 3-PF ( r s = 0.639, P < 0.001 ) improvement rates. The improvement in the sum of rigidity items (UPDRS motor subsection item 22) was also correlated with HS ( r s = 0.389, P = 0.037 ) and 3-PF ( r s = 0.373, P = 0.046 ) improvement rates. Conclusions . Exogenous levodopa supplementation can significantly reduce the rigidity of patients with PD, improve their 3-PF and 4-DF of ankle joint kinematic parameters, and ultimately enhance their gait.

Wu, Zhuang↗