Search NASA⌕ Search

SEARCH · Search NASA

Results for “Datasets”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

Quantifying Rates of Erosion Using Historical Aerial Photos - 19478

Erosion can play an important role in the fate and transport of waste at sites where disposal of long-lived waste is anticipated. The statistical characterization of key processes related to erosion is essential to the understanding of site stability through time. In this work multi-temporal historical aerial images are analyzed in conjunction with orthophotography and Lidar data to develop probability distributions for variables representing important erosion processes. Scans of photographic negatives were obtained for multiple photographs and several negatives were scanned with a calibrated photogrammetric scanner by Geomni (formerly Blue Skies Consulting) in Belen, New Mexico. Other negatives were provided by USDA or scanned on a high-resolution, large format media scanner in the United States National Archives Cartographic Research Room, College Park, Maryland (1939). An additional set of aerial photographs was obtained from the USGS EROS Data Center web site. For other years, photographic prints were available for aerial photography. Several prints were scanned with a large-format media scanner at 1200 dpi. Ground control points for selected digital images used in the stereoscopic analyses were identified in ArcMap. Ground control points were collected by matching features which could be identified in the aerial photography as well as the orthophotography or shaded relief imagery from the Lidar dataset. Such features included fence line intersections, road intersections, railroad bridges, and structures, depending on the age of the photography. Many old fence lines and abandoned roads remained visible in the shaded relief imagery while they were completely obscured by tree canopy in modern photography. Ground control elevations were sampled from the Lidar-based DEM or directly from point clouds. The image coordinates and matching three-dimensional projected coordinates of the ground control points were exported to IDL where parameters for a three-dimensional direct linear transformation (DLT) were obtained. Built-in singular value decomposition routines were used to solve an overdetermined set of equations for the eleven parameters of the DLT for a particular historical photograph. A solution to the DLT parameters was obtained for each historical aerial photograph in which features of interest were identified using the stereoscope. Ultimately, this process resulted in the identification of locations for features like gully heads using both the Lidar dataset and projection of the estimated location from the historical aerial photo under consideration back to the Lidar dataset. The distance between the estimate of the location from the historical image and that of the Lidar dataset was the estimated distance the feature has moved. This distance was then divided by the number of years between the Lidar dataset and the year of the historical aerial image of interest to get a rate of movement through time. This was done for several dozen points on each historical aerial image. There was inevitable uncertainty associated with the estimation of points from the historical aerial imagery. This includes estimation of changes in locations of features like gully heads through time. In this work a method to estimate the uncertainty associated with measurements of locations of features using the stereoscopic analysis is developed and applied. For features with locations in space that do not change (e.g., road intersections, etc.) the difference in measurements of locations from the Lidar dataset and that of the estimate from the historical aerial image provides an observation of the measurement error. These points used to estimate the measurement error are referred to as control points. For each of the historical aerial images, a different measurement error distribution is estimated using control points. These measurement errors are combined with the estimated distances from the stereoscopic analyses to produce distributions of gully retreat rates and hillslope erosion rates used along with output from Erosion Working Group (EWG) Landscape Evolution Models (LEMs) to provide statistical probability distributions for input into the PPA Model. Specifically, gully head retreat rate and gully widening rate were characterized using statistical probability distributions. The central limit theorem was then applied to develop rates that represent long-term averages that are used to inform a PPA Model built in GoldSim. The importance of these rates with respect to characterization of future risk can then assessed using sensitivity analyses. This provides an approach to determine if subsequent reduction of the uncertainty associated with the probability distributions of erosion rates will correspond to meaningful reduction in the estimation of future risk from the site. Ultimately this is a general method that utilizes historical aerial imagery to estimate rates of erosion with uncertainty. This information can be used to inform PPA models to project future risks from a given site. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Web-based Preprocessing and Visualization of 3D FIB Tomography Data for Nuclear Fuel Characterization

Three-dimensional (3D) focused ion beam (FIB) tomography enables reconstruction of internal nuclear fuel features that can't be fully evaluated through surface imaging alone. This capability supports characterization of fuel constituents and defects under thermal and irradiation conditions relevant to microreactor development. However, large tomography datasets can create data-handling, loading, and visualization challenges, especially when image-stack preparation and file conversion must be completed with separate tools. The Computational Ultraspatial Tomography Toolkit for High-Resolution Object Analysis Tools (CUTTRHOAT) is an open-source web application being developed to display FIB tomography datasets available through the Nuclear Research Data System (NRDS). The current alpha version requires prepared HDF5 datasets and has limited integrated data-preparation capabilities. This project improves CUTTHROAT by adding dataset-folder selection, automatic input detection, dataset scanning, missing-slice identification, blank-slice insertion, and image-stack-to-HDF5 conversion. Two applications will be compared: the baseline CUTTHROAT alpha workflow and the updated application containing the integrated data-handling and preprocessing functions. Evaluation will consider dataset detection accuracy, conversion success, loading time, rendering responsiveness, application stability, and user interaction. Preliminary results demonstrate successful loading of existing HDF5 files and converted image stacks, while testing also identified performance reductions caused by excessive blank-slice generation. The updated workflow reduces reliance on external preparation tools and supports more direct movement from image stacks to color-code 3D visualization. Future work includes refining missing-slice handling, integrating additional preprocessing functions, like a denoising feature, parsing TIFF metadata for automatic voxel scaling, and adding manual X, Y, and Z voxel-spacing inputs for PNG and JPEG.

36 - MATERIALS SCIENCE↗

Towards robust surrogate models: Benchmarking machine learning approaches to expediting phase field simulations of brittle fracture

Data-driven approaches have the potential to make modeling complex, nonlinear physical phenomena significantly more computationally tractable. For example, computational modeling of fracture is a core challenge where machine learning techniques have the potential to provide a much needed speedup that would enable progress in areas such as multi-scale modeling and uncertainty quantification. Currently, phase field modeling (PFM) of fracture is one such approach that offers a convenient variational formulation to model crack nucleation, branching and propagation. To date, machine learning techniques have shown promise in approximating PFM simulations. While standard fracture benchmarks represent realistic scenarios frequently observed in practice, they typically do not provide sufficiently challenging tests for data-driven methods. Here, to address this gap, we introduce a challenging dataset based on PFM simulations designed to benchmark and advance ML methods for fracture modeling. This dataset includes three energy decomposition methods, two boundary conditions, and 1000 random initial crack configurations for a total of 6000 simulations. Each sample contains 100 time steps capturing the temporal evolution of the crack field. Alongside this dataset, we also implement and evaluate Physics Informed Neural Networks (PINN), Fourier Neural Operators (FNO), and UNet models as baselines, and explore the impact of ensembling strategies on prediction accuracy. With this combination of our dataset and baseline models drawn from the literature we aim to provide a standardized and challenging benchmark for evaluating machine learning approaches to solid mechanics. Our results highlight both the promise and limitations of popular current models, and demonstrate the utility of this dataset as a testbed for advancing machine learning in fracture mechanics research.

Benchmark dataset↗

Predicting Overall Survival After Stereotactic Ablative Radiation Therapy in Early-Stage Lung Cancer: Development and External Validation of the Amsterdam Prognostic Model

Purpose: A prognostic model for 5-year overall survival (OS), consisting of recursive partitioning analysis (RPA) and a nomogram, was developed for patients with early-stage non-small cell lung cancer (ES-NSCLC) treated with stereotactic ablative radiation therapy (SABR). Methods and Materials: A primary dataset of 703 ES-NSCLC SABR patients was randomly divided into a training (67%) and an internal validation (33%) dataset. In the former group, 21 unique parameters consisting of patient, treatment, and tumor factors were entered into an RPA model to predict OS. Univariate and multivariate models were constructed for RPA-selected factors to evaluate their relationship with OS. A nomogram for OS was constructed based on factors significant in multivariate modeling and validated with calibration plots. Both the RPA and the nomogram were externally validated in independent surgical (n=193) and SABR (n=543) datasets. Results: RPA identified 2 distinct risk classes based on tumor diameter, age, World Health Organization performance status (PS) and Charlson comorbidity index. This RPA had moderate discrimination in SABR datasets (c-index range: 0.52-0.60) but was of limited value in the surgical validation cohort. The nomogram predicting OS included smoking history in addition to RPA-identified factors. In contrast to RPA, validation of the nomogram performed well in internal validation (r{sup 2}=0.97) and external SABR (r{sup 2}=0.79) and surgical cohorts (r{sup 2}=0.91). Conclusions: The Amsterdam prognostic model is the first externally validated prognostication tool for OS in ES-NSCLC treated with SABR available to individualize patient decision making. The nomogram retained strong performance across surgical and SABR external validation datasets. RPA performance was poor in surgical patients, suggesting that 2 different distinct patient populations are being treated with these 2 effective modalities.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Data-driven probability concentration and sampling on manifold

A new methodology is proposed for generating realizations of a random vector with values in a finite-dimensional Euclidean space that are statistically consistent with a dataset of observations of this vector. The probability distribution of this random vector, while a priori not known, is presumed to be concentrated on an unknown subset of the Euclidean space. A random matrix is introduced whose columns are independent copies of the random vector and for which the number of columns is the number of data points in the dataset. The approach is based on the use of (i) the multidimensional kernel-density estimation method for estimating the probability distribution of the random matrix, (ii) a MCMC method for generating realizations for the random matrix, (iii) the diffusion-maps approach for discovering and characterizing the geometry and the structure of the dataset, and (iv) a reduced-order representation of the random matrix, which is constructed using the diffusion-maps vectors associated with the first eigenvalues of the transition matrix relative to the given dataset. The convergence aspects of the proposed methodology are analyzed and a numerical validation is explored through three applications of increasing complexity. The proposed method is found to be robust to noise levels and data complexity as well as to the intrinsic dimension of data and the size of experimental datasets. Both the methodology and the underlying mathematical framework presented in this paper contribute new capabilities and perspectives at the interface of uncertainty quantification, statistical data analysis, stochastic modeling and associated statistical inverse problems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Constraining the dynamical dark energy parameters: Planck-2013 vs WMAP9

We determine the best-fit values and confidence limits for dynamical dark energy parameters together with other cosmological parameters on the basis of different datasets which include WMAP9 or Planck-2013 results on CMB anisotropy, BAO distance ratios from recent galaxy surveys, magnitude-redshift relations for distant SNe Ia from SNLS3 and Union2.1 samples and the HST determination of the Hubble constant. We use a Markov Chain Monte Carlo routine to map out the likelihood in the multi-dimensional parameter space. We show that the most precise determination of cosmological parameters with the narrowest confidence limits is obtained for the Planck+HST+BAO+SNLS3 dataset. The best-fit values and 2σ confidence limits for cosmological parameters in this case are Ω{sub de} = 0.718±0.022, w{sub 0} = −1.15{sup +0.14}{sub −0.16}, c{sub a}{sup 2} = −1.15{sup +0.02}{sub −0.46}, Ω{sub b}h{sup 2} = 0.0220±0.0005, Ω{sub cdm}h{sup 2} = 0.121±0.004, h = 0.713±0.027, n{sub s} = 0.958{sup +0.014}{sub −0.010}, A{sub s} = (2.215{sup +0.093}{sub −0.101})⋅10{sup −9}, τ{sub rei} = 0.093{sup +0.022}{sub −0.028}. For this dataset, the ΛCDM model is just outside the 2σ confidence region, while for the dataset WMAP9+HST+BAO+SNLS3 the ΛCDM model is only 1σ away from the best fit. The tension in the determination of some cosmological parameters on the basis of two CMB datasets WMAP9 and Planck-2013 is highlighted.

79 ASTRONOMY AND ASTROPHYSICS↗

Neutrino constraints: what large-scale structure and CMB data are telling us?

We discuss the reliability of neutrino mass constraints, either active or sterile, from the combination of different low redshift Universe probes with measurements of CMB anisotropies. In our analyses we consider WMAP 9-year or Planck Cosmic Microwave Background (CMB) data in combination with Baryonic Acoustic Oscillations (BAO) measurements from BOSS DR11, galaxy shear measurements from CFHTLenS, SDSS Ly α forest constraints and galaxy cluster mass function from Chandra observations. At odds with recent similar studies, to avoid model dependence of the constraints we perform a full likelihood analysis for all the datasets employed. As for the cluster data analysis we rely on to the most recent calibration of massive neutrino effects in the halo mass function and we explore the impact of the uncertainty in the mass bias and re-calibration of the halo mass function due to baryonic feedback processes on cosmological parameters. We find that none of the low redshift probes alone provide evidence for massive neutrino in combination with CMB measurements, while a larger than 2σ detection of non zero neutrino mass, either active or sterile, is achieved combining cluster or shear data with CMB and BAO measurements. Yet, the significance of the detection exceeds 3σ if we combine all four datasets. For a three active neutrino scenario, from the joint analysis of CMB, BAO, shear and cluster data including the uncertainty in the mass bias we obtain ∑ m{sub ν} =0.29{sup +0.18}{sub -0.21} eV and ∑ m{sub ν} =0.22{sup +0.17}{sub -0.18} eV 95%CL) using WMAP9 or Planck as CMB dataset, respectively. The preference for massive neutrino is even larger in the sterile neutrino scenario, for which we get m{sub s}{sup eff}=0.44{sup +0.28}{sub -0.26} eV and Δ N{sub eff}=0.78{sup +0.60}{sub -0.59} 95%CL) from the joint analysis of Planck, BAO, shear and cluster datasets. For this data combination the vanilla ΛCDM model is rejected at more than 3σ and a sterile neutrino mass as motivated by accelerator anomaly is within the 2σ errors. Conversely, the Ly α data favour vanishing neutrino masses and from the data combination Planck+BAO+Ly α we get the tight upper limits ∑ m{sub ν} <0.14 eV and m{sub s}{sup eff}<0.22 eV—Δ N{sub eff}<1.11 95%CL) for the active and sterile neutrino model, respectively. Finally, results from the full data combination reflect the tension between the σ{sub 8} constraints obtained from cluster and shear data and that inferred from Ly α forest measurements; in the active neutrino scenario for both CMB datasets employed, the full data combination yields only an upper limits on ∑ m{sub ν}, while assuming an extra sterile neutrino we still get preference for non-vanishing mass, m{sub s}{sup eff}=0.26{sup +0.22}{sub -0.24} eV, and dark contribution to the radiation content, Δ N{sub eff}=0.82±0.55.

79 ASTRONOMY AND ASTROPHYSICS↗

SpaceNet 9—Cross-Sensor Alignment of Optical and SAR Imagery

Precise registration of high-resolution synthetic aperture radar (SAR) and optical imagery is necessary for realizing the full potential and benefits of multimodal image analysis. However, two significant challenges presently exist. First, there is a lack of annotated datasets and benchmarks available for high-resolution SAR–optical image registration. Second, an assessment of efficient and reliable image registration methods that can precisely align these modalities is lacking. Here, we present a holistic description of the SpaceNet 9 Challenge and its results. We present a description of the dataset and baseline algorithm along with the results of the challenge, including a description of the winning algorithms. We release the SpaceNet 9 dataset along with open-sourcing the winning algorithms and baseline. The objective of SpaceNet 9 was to compute a dense displacement map that indicates the shift needed to align pixels in an optical image to the pixels in a SAR image. The challenge launched in April 2025 and was active for approximately two months. The top five solutions reduced image alignment error from approximately 34 m to under 13 m for public and private test data, with the best results obtaining a registration error of only 8.5 and 6.7 m on the public testing and private testing dataset, respectively. Usage of pretrained image matching models, robust outlier rejection with RANSAC, and estimating local displacement were common among the top solutions. The results of this challenge provide insight into high-resolution SAR–optical image registration and offer opportunities for future benchmarking in this domain. The baseline algorithm, winning solutions, and datasets are available at https://spacenet.ai/sn9-challenge/.

benchmark datasets↗

Investigation of a breathing surrogate prediction algorithm for prospective pulmonary gating

Purpose: A major challenge of four dimensional computed tomography (4DCT) in treatment planning and delivery has been the lack of respiration amplitude and phase reproducibility during image acquisition. The implementation of a prospective gating algorithm would ensure that images would be acquired only during user-specified breathing phases. This study describes the development and testing of an autoregressive moving average (ARMA) model for human respiratory phase prediction under quiet respiration conditions. Methods: A total of 47 4DCT patient datasets and synchronized respiration records was utilized in this study. Three datasets were used in model development and were removed from further evaluation of the ARMA model. The remaining 44 patient datasets were evaluated with the ARMA model for prediction time steps from 50 to 1000 ms in increments of 50 and 100 ms. Thirty-five of these datasets were further used to provide a comparison between the proposed ARMA model and a commercial algorithm with a prediction time step of 240 ms. Results: The optimal number of parameters for the ARMA model was based on three datasets reserved for model development. Prediction error was found to increase as the prediction time step increased. The minimum prediction time step required for prospective gating was selected to be half of the gantry rotation period. The maximum prediction time step with a conservative 95% confidence criterion was found to be 0.3 s. The ARMA model predicted peak inhalation and peak exhalation phases significantly better than the commercial algorithm. Furthermore, the commercial algorithm had numerous instances of missed breath cycles and falsely predicted breath cycles, while the proposed model did not have these errors. Conclusions: An ARMA model has been successfully applied to predict human respiratory phase occurrence. For a typical CT scanner gantry rotation period of 0.4 s (0.2 s prediction time step), the absolute error was relatively small, 0.06{+-}0.02 s at peak inhalation and 0.05{+-}0.04 s at peak exhalation. The application of the ARMA model for prospective pulmonary gating has been demonstrated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-173: Evaluation of Deformable Registration for Correcting Respiratory Motion in 4DCT Lung Images

Purpose: Deformable Image Registration (DIR) is gaining wider clinical acceptance in radiation oncology. The aim of this work is to characterise a DIR algorithm on publically available 4DCT lung images, such that comparison can be performed against other algorithms. We propose an evaluation method of registration accuracy that takes into account the initial misregistration of the datasets. Methods: The “DIR Validation dataset” ( http://www.creatis.insa-lyon.fr/rio/dir{sub v}alidation{sub d}ata ) provides benchmark data for evaluating 3D CT registration algorithms. It consists of six 4DCT lung datasets (1x1x2mm resolution) with 100 landmarks identified on the end-exhalation and end-inhalation phases. Images were registered to end-inhalation using proprietary form of optical flow in commercial software (Mirada RTx, Mirada Medical, UK). Target registration error was measured before and after DIR, referred to as Initial Registration Error (IRE) and Final Registration Error (FRE). Results: The mean FRE over all landmarks was 1.37±1.81mm. FRE increased with IRE. Mean FRE of 0.86, 0.86, 1.53, 3.38, 4.45, 7.58mm was observed for IRE in the ranges 0–5, 5–10, 10–15, 15–20, 20–25, >25 mm. Higher FRE was observed at the inferior lung, where IRE was greater. Out-of-plane motion contributed more to IRE, and therefore to FRE. Maximum FRE of 20.6mm was observed for IRE of 32.1mm, located at the posterior of the middle lobe for dataset 2. Sub-voxel registration accuracy was achieved for up to 10mm IRE, and increased linearly at 0.3mm FRE/mm IRE thereafter. Conclusion: Publicly available clinical datasets enable algorithms to be compared objectively between publications. However, only reporting average TRE after registration can be misleading as the ability of an algorithm to correct for displacements varies with the IRE or position within the patient. Consequently, algorithms should be characterized using the entire range of initial displacements. For the algorithm assessed, clinically acceptable error within one voxel was achieved for IRE of up to 15mm. TK, AL, and MG are employees of Mirada Medical.

60 APPLIED LIFE SCIENCES↗

TH-A-9A-01: Active Optical Flow Model: Predicting Voxel-Level Dose Prediction in Spine SBRT

Purpose: To predict voxel-level dose distribution and enable effective evaluation of cord dose sparing in spine SBRT. Methods: We present an active optical flow model (AOFM) to statistically describe cord dose variations and train a predictive model to represent correlations between AOFM and PTV contours. Thirty clinically accepted spine SBRT plans are evenly divided into training and testing datasets. The development of predictive model consists of 1) collecting a sequence of dose maps including PTV and OAR (spinal cord) as well as a set of associated PTV contours adjacent to OAR from the training dataset, 2) classifying data into five groups based on PTV's locations relative to OAR, two “Top”s, “Left”, “Right”, and “Bottom”, 3) randomly selecting a dose map as the reference in each group and applying rigid registration and optical flow deformation to match all other maps to the reference, 4) building AOFM by importing optical flow vectors and dose values into the principal component analysis (PCA), 5) applying another PCA to features of PTV and OAR contours to generate an active shape model (ASM), and 6) computing a linear regression model of correlations between AOFM and ASM.When predicting dose distribution of a new case in the testing dataset, the PTV is first assigned to a group based on its contour characteristics. Contour features are then transformed into ASM's principal coordinates of the selected group. Finally, voxel-level dose distribution is determined by mapping from the ASM space to the AOFM space using the predictive model. Results: The DVHs predicted by the AOFM-based model and those in clinical plans are comparable in training and testing datasets. At 2% volume the dose difference between predicted and clinical plans is 4.2±4.4% and 3.3±3.5% in the training and testing datasets, respectively. Conclusion: The AOFM is effective in predicting voxel-level dose distribution for spine SBRT. Partially supported by NIH/NCI under grant #R21CA161389 and a master research grant by Varian Medical System.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TH-C-BRD-05: Reducing Proton Beam Range Uncertainty with Patient-Specific CT HU to RSP Calibrations Based On Single-Detector Proton Radiography

Purpose: Beam range uncertainty in proton treatment comes primarily from converting the patient's X-ray CT (xCT) dataset to relative stopping power (RSP). Current practices use a single curve for this conversion, produced by a stoichiometric calibration based on tissue composition data for average, healthy, adult humans, but not for the individual in question. Proton radiographs produce water-equivalent path length (WEPL) maps, dependent on the RSP of tissues within the specific patient. This work investigates the use of such WEPL maps to optimize patient-specific calibration curves for reducing beam range uncertainty. Methods: The optimization procedure works on the principle of minimizing the difference between the known WEPL map, obtained from a proton radiograph, and a digitally-reconstructed WEPL map (DRWM) through an RSP dataset, by altering the calibration curve that is used to convert the xCT into an RSP dataset. DRWMs were produced with Plastimatch, an in-house developed software, and an optimization procedure was implemented in Matlab. Tests were made on a range of systems including simulated datasets with computed WEPL maps and phantoms (anthropomorphic and real biological tissue) with WEPL maps measured by single detector proton radiography. Results: For the simulated datasets, the optimizer showed excellent results. It was able to either completely eradicate or significantly reduce the root-mean-square-error (RMSE) in the WEPL for the homogeneous phantoms (to zero for individual materials or from 1.5% to 0.2% for the simultaneous optimization of multiple materials). For the heterogeneous phantom the RMSE was reduced from 1.9% to 0.3%. Conclusion: An optimization procedure has been designed to produce patient-specific calibration curves. Test results on a range of systems with different complexities and sizes have been promising for accurate beam range control in patients. This project was funded equally by the Engineering and Physical Sciences Research Council (UK) and Ion Beam Applications (Louvain-La-Neuve, Belgium)

07 ISOTOPE AND RADIATION SOURCES↗

SU-C-BRA-04: Use of Esophageal Wall Thickness in Evaluation of the Response to Chemoradiation Therapy for Esophageal Cancer

Purpose: To quantitatively evaluate the esophageal cancer response to chemoradiation therapy (CRT) by measuring the esophageal wall thickness in CT. Method: Two datasets were used in this study. The first dataset is composed of CT scans of 15 esophageal cancer patients and 15 normal controls. The second dataset is composed of 20 esophageal cancer patients who underwent PET/CT scans before (Pre-CRT) and after CRT (Post-CRT). We first segmented the esophagus using a multi-atlas-based algorithm. The esophageal wall thickness was then computed, on each slice, as the equivalent circle radius of the segmented esophagus excluding the lumen. To evaluate the changes of wall thickness, we computed the standard deviation (SD), coefficient of variation (COV, SD/Mean), and flatness [(Max–Min)/Mean] of wall thickness along the entire esophagus. Results: For the first dataset, the mean wall thickness of cancer patients and normal controls were 6.35 mm and 6.03 mm, respectively. The mean SD, COV, and flatness of the wall thickness were 2.59, 0.21, and 1.27 for the cancer patients and 1.99, 0.16, and 1.13 for normal controls. Statistically significant differences (p < 0.05) were identified in SD and flatness. For the second dataset, the mean wall thickness of pre-CRT and post-CRT patients was 7.13 mm and 6.84 mm, respectively. The mean SD, COV, and flatness were 1.81, 0.26, and 1.06 for pre-CRT and 1.69, 0.26, and 1.06 for post-CRT. Statistically significant difference was not identified for these measurements. Current results are based on the entire esophagus. We believe significant differences between pre- and post-CRT scans could be obtained, if we conduct the measurements at tumor sites. Conclusion: Results show thicker wall thickness in pre-CRT scans and differences in wall thickness changes between normal and abnormal esophagus. This demonstrated the potential of esophageal wall thickness as a marker in the tumor CRT response evaluation. This work was supported in part by the National Cancer Institute Grant R01CA172638.

60 APPLIED LIFE SCIENCES↗

SU-E-T-333: Dosimetric Impact of Rotational Error On the Target Coverage in IMPT Lung Cancer Plans

Purpose: The main purpose of this study was to investigate the impact of rotational (yaw, roll, and pitch) error on the planning target volume (PTV) coverage in lung cancer plans generated by intensity modulated proton therapy (IMPT). Methods: In this retrospective study, computed tomography (CT) dataset of previously treated lung case was used. IMPT plan were generated on the original CT dataset using left-lateral (LL) and posterior-anterior (PA) beams for a total dose of 74 Gy[RBE] with 2 Gy[RBE] per fraction. In order to investigate the dosimetric impact of rotational error, 12 new CT datasets were generated by re-sampling the original CT dataset for rotational (roll, yaw, and pitch) angles ranged from −5° to +5°, with an increment of 2.5°. A total of 12 new IMPT plans were generated based on the re-sampled CT datasets using beam parameters identical to the ones in the original IMPT plan. All treatment plans were generated in XiO treatment planning system. The PTV coverage (i.e., dose received by 95% of the PTV volume, D95) in new IMPT plans were then compared with the PTV coverage in the original IMPT plan. Results: Rotational errors caused the reduction in the PTV coverage in all 12 new IMPT plans when compared to the original IMPT lung plan. Specifically, the PTV coverage was reduced by 4.94% to 50.51% for yaw, by 4.04% to 23.74% for roll, and by 5.21% to 46.88% for pitch errors. Conclusion: Unacceptable dosimetric results were observed in new IMPT plans as the PTV coverage was reduced by up to 26.87% and 50.51% for rotational error of 2.5° and 5°, respectively. Further investigation is underway in evaluating the PTV coverage loss in the IMPT lung cancer plans for smaller rotational angle change.

60 APPLIED LIFE SCIENCES↗

WE-AB-204-08: Uncertainties in Kinetic Modeling of Shortened Dynamic 18F-FMISO PET Due to Image Noise

Purpose: To assess uncertainties in voxel-wise kinetic modeling (KM) of dynamic 18F-FMISO PET (dPET) due to image noise for different lengths of dPET acquisitions. Methods: 12 tumor time activity curves (TACs) deduced from 6 head and neck cancer patient dPET datasets (45min dPET + 10min frames at ∼95min and ∼160min respectively) were modeled using an irreversible two-tissue compartment model to estimate kinetic rate constants (KRCs) k3, vB, K1, and K1/k2 (reference standard). For each modeled TAC, 1000 noisy TACs were simulated by adding Gaussian noise with standard deviation equivalent to that observed on a voxel level in GE DSTE PET-CT. KM was conducted for each set of noisy TACs using (i) full dataset (170min), and repeated using (ii) 105min and (iii) 45min shortened subsets, with an input function that was image-derived from the dPET dataset of matching length. Absolute value of percent difference between KRCs from noisy TACs as estimated from either of 3 datasets and reference standard KRCs was used to represent bias. Results: For all KRCs, bias was higher for shortened datasets. For k3, bias was lower when actual k3 was higher: from 7%±5% (170min), 9%±7% (105min), and 14%±11% (45min) (actual k3=0.0098), to 32%±25% (170min), 45%±34% (95min), and 79%±48% (45min) (actual k3=0.0008). Similar relationship was observed for vB, with bias being between ∼7% (actual vB=0.28) and ∼26–34% (actual vB=0.08). For K1 [K1/k2], bias was ∼6–10% [∼2–3%] (dependence on actual value of K1 [K1/k2] was not observed). Conclusion: Uncertainties in voxel-wise KM of shortened 18F-FMISO dPET due to image noisy only are larger for shorter acquisitions and, for k3 [vB], the bias was found to be inversely correlated with the actual values of k3 [vB]. Using 45min subset, k3, vB, K1, and K1/k2 could be estimated to within ∼15–80%, ∼10–35%, ∼10%, and ∼3%, respectively.

60 APPLIED LIFE SCIENCES↗

WE-G-207-06: 3D Fluoroscopic Image Generation From Patient-Specific 4DCBCT-Based Motion Models Derived From Physical Phantom and Clinical Patient Images

Purpose: Respiratory-correlated cone-beam CT (4DCBCT) images acquired immediately prior to treatment have the potential to represent patient motion patterns and anatomy during treatment, including both intra- and inter-fractional changes. We develop a method to generate patient-specific motion models based on 4DCBCT images acquired with existing clinical equipment and used to generate time varying volumetric images (3D fluoroscopic images) representing motion during treatment delivery. Methods: Motion models are derived by deformably registering each 4DCBCT phase to a reference phase, and performing principal component analysis (PCA) on the resulting displacement vector fields. 3D fluoroscopic images are estimated by optimizing the resulting PCA coefficients iteratively through comparison of the cone-beam projections simulating kV treatment imaging and digitally reconstructed radiographs generated from the motion model. Patient and physical phantom datasets are used to evaluate the method in terms of tumor localization error compared to manually defined ground truth positions. Results: 4DCBCT-based motion models were derived and used to generate 3D fluoroscopic images at treatment time. For the patient datasets, the average tumor localization error and the 95th percentile were 1.57 and 3.13 respectively in subsets of four patient datasets. For the physical phantom datasets, the average tumor localization error and the 95th percentile were 1.14 and 2.78 respectively in two datasets. 4DCBCT motion models are shown to perform well in the context of generating 3D fluoroscopic images due to their ability to reproduce anatomical changes at treatment time. Conclusion: This study showed the feasibility of deriving 4DCBCT-based motion models and using them to generate 3D fluoroscopic images at treatment time in real clinical settings. 4DCBCT-based motion models were found to account for the 3D non-rigid motion of the patient anatomy during treatment and have the potential to localize tumor and other patient anatomical structures at treatment time even when inter-fractional changes occur. This project was supported, in part, through a Master Research Agreement with Varian Medical Systems, Inc., Palo Alto, CA. The project was also supported, in part, by Award Number R21CA156068 from the National Cancer Institute.

60 APPLIED LIFE SCIENCES↗

Quantifying the accuracy of the tumor motion and area as a function of acceleration factor for the simulation of the dynamic keyhole magnetic resonance imaging method

Purpose: The dynamic keyhole is a new MR image reconstruction method for thoracic and abdominal MR imaging. To date, this method has not been investigated with cancer patient magnetic resonance imaging (MRI) data. The goal of this study was to assess the dynamic keyhole method for the task of lung tumor localization using cine-MR images reconstructed in the presence of respiratory motion. Methods: The dynamic keyhole method utilizes a previously acquired a library of peripheral k-space datasets at similar displacement and phase (where phase is simply used to determine whether the breathing is inhale to exhale or exhale to inhale) respiratory bins in conjunction with central k-space datasets (keyhole) acquired. External respiratory signals drive the process of sorting, matching, and combining the two k-space streams for each respiratory bin, thereby achieving faster image acquisition without substantial motion artifacts. This study was the first that investigates the impact of k-space undersampling on lung tumor motion and area assessment across clinically available techniques (zero-filling and conventional keyhole). In this study, the dynamic keyhole, conventional keyhole and zero-filling methods were compared to full k-space dataset acquisition by quantifying (1) the keyhole size required for central k-space datasets for constant image quality across sixty four cine-MRI datasets from nine lung cancer patients, (2) the intensity difference between the original and reconstructed images in a constant keyhole size, and (3) the accuracy of tumor motion and area directly measured by tumor autocontouring. Results: For constant image quality, the dynamic keyhole method, conventional keyhole, and zero-filling methods required 22%, 34%, and 49% of the keyhole size (P < 0.0001), respectively, compared to the full k-space image acquisition method. Compared to the conventional keyhole and zero-filling reconstructed images with the keyhole size utilized in the dynamic keyhole method, an average intensity difference of the dynamic keyhole reconstructed images (P < 0.0001) was minimal, and resulted in the accuracy of tumor motion within 99.6% (P < 0.0001) and the accuracy of tumor area within 98.0% (P < 0.0001) for lung tumor monitoring applications. Conclusions: This study demonstrates that the dynamic keyhole method is a promising technique for clinical applications such as image-guided radiation therapy requiring the MR monitoring of thoracic tumors. Based on the results from this study, the dynamic keyhole method could increase the imaging frequency by up to a factor of five compared with full k-space methods for real-time lung tumor MRI.

60 APPLIED LIFE SCIENCES↗

Functional analysis of metagenomes and metatranscriptomes using SEED and KEGG

Background: Metagenomics is the study of microbial organisms using sequencing applied directly to environmental samples. Technological advances in next-generation sequencing methods are fueling a rapid increase in the number and scope of metagenome projects. While metagenomics provides information on the gene content, metatranscriptomics aims at understanding gene expression patterns in microbial communities. The initial computational analysis of a metagenome or metatranscriptome addresses three questions: (1) Who is out there? (2) What are they doing? and (3) How do different datasets compare? There is a need for new computational tools to answer these questions. In 2007, the program MEGAN (MEtaGenome ANalyzer) was released, as a standalone interactive tool for analyzing the taxonomic content of a single metagenome dataset. The program has subsequently been extended to support comparative analyses of multiple datasets. Results: The focus of this paper is to report on new features of MEGAN that allow the functional analysis of multiple metagenomes (and metatranscriptomes) based on the SEED hierarchy and KEGG pathways. We have compared our results with the MG-RAST service for different datasets. Conclusions: The MEGAN program now allows the interactive analysis and comparison of the taxonomical and functional content of multiple datasets. As a stand-alone tool, MEGAN provides an alternative to web portals for scientists that have concerns about uploading their unpublished data to a website.

59 BASIC BIOLOGICAL SCIENCES↗