Search NASA⌕ Search

SEARCH · Search NASA

Results for “Extremism”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

Elongation of extreme ultraviolet (at 13.5 nm) emission with time-of-flight controlled discharges and lateral fuel injection

A way toward a quasicontinuous extreme ultraviolet (EUV) radiation source is proposed and explored. Tin and lithium vapor discharges with the lateral laser-ablation injection are experimentally studied as possible efficient sources of quasicontinuous emission of EUV radiation at a wavelength of 13.5 nm. It is shown that the time-of-flight control of optimal plasma parameters by means of varying ablating laser pulse parameters provides a considerable elongation of maximal-power EUV emission with an overall efficiency of 0.1% and with an energy output exceeding 1% of the energy deposited in the discharge plasma. Along with a high average power and a stable position, such an emitter may have its size small enough to be used in the projection lithography.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High brightness extreme ultraviolet (at 13.5 nm) emission from time-of-flight controlled discharges with coaxial fuel injection

Extreme ultraviolet (EUV) emission from discharge produced plasma with the coaxial injection of fuel vapor (tin and lithium) produced by laser ablation is experimentally studied. Multiple plasma pinches preceding a strong and long recombination radiation of EUV are observed in the first half cycle of a sinusoidal discharge current. Due to the time-of-flight control type of the discharge, the shape of pinch radiation pulses is almost identical. With the coaxial injection of time-of-flight controlled discharges, the highest brightness of EUV emission (maximum extracted energy of 244.3 mJ/2{pi} sr per pulse with the emitter size of {approx}1x0.3 mm{sup 2} in full width at half maximum) is provided with efficiency exceeding 2% of deposited energy into the plasma (or 1% of dissipated energy in the discharge) due to a much better matching with the optimal plasma parameters in the recombination regime and a decrease in the off-duty factor. Stability of emitting plasma of the repetitive pinches is essentially improved with use of a second laser pulse.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Determination of electron-heated temperatures of petawatt laser-irradiated foil targets with 256 and 68 eV extreme ultraviolet imaging

Measurements of plasma temperature at the rear surface of foil targets due to heating by hot electrons, which were produced in short pulse high intensity laser matter interactions using the 150 J, 0.5 ps Titan laser, are reported. Extreme ultraviolet (XUV) imaging at 256 and 68 eV energies is used to determine spatially resolved target rear surface temperature patterns by comparing absolute intensities to radiation hydrodynamic modeling. XUV mirrors at these two energies were absolutely calibrated at the Advanced Light Source at the Lawrence Berkeley Laboratory. Temperatures deduced from both imagers are validated against each other within the range of 75-225 eV.

07 ISOTOPE AND RADIATION SOURCES↗

Extreme ultraviolet emission from dense plasmas generated with sub-10-fs laser pulses

The extreme ultraviolet (XUV) emission from dense plasmas generated with sub-10-fs laser pulses with varying peak intensities up to 3x10{sup 16} W/cm{sup 2} is investigated for different target materials. K shell spectra are obtained from low Z targets (carbon and boron nitride). In the spectra, a series limit for the hydrogen- and helium-like resonance lines is observed, indicating that the plasma is at high density and that pressure ionization has removed the higher levels. In addition, L shell spectra from titanium targets were obtained. Basic features of the K and L shell spectra are reproduced with computer simulations. The calculations include hydrodynamic simulation of the plasma expansion and collisional radiative calculations of the XUV emission.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Attosecond nonlinear Fourier transformation spectroscopy of CO{sub 2} in extreme ultraviolet wavelength region

The interferometric autocorrelation functions of attosecond pulse trains in the time domain were measured by detecting CO{sub 2}{sup 2+} as well as the atomic and molecular fragment ions generated via two-photon absorption of intense vacuum ultraviolet-extreme ultraviolet light by CO{sub 2}. It was demonstrated that the Fourier transformation of the interferometric autocorrelation functions of the respective fragment ions appearing in a time-of-flight mass spectrum exhibit spectroscopic information in the frequency domain corresponding to the two-photon photofragment excitation spectra of CO{sub 2} and the double ionization excitation spectrum to form CO{sub 2}{sup 2+}.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optimization of the size ratio of Sn sphere and laser focal spot for an extreme ultraviolet light source

The effect of the ratio of Sn sphere diameter to laser focal spot size (SD/FSS) on conversion efficiency (CE) from laser to in-band (2%) 13.5 nm extreme ultraviolet (EUV) light was investigated by fixing the laser spot size and irradiating variable diameter spheres. It was found that a minimum SD/FSS, i.e., 2.5, is necessary to produce high in-band CE, which is 15% higher than planar targets. Two-dimensional plasma density profile maps showed that the density of the dominant in-band EUV emission region and the size of the surrounding absorbing plasma can be manipulated by geometric effects of the SD/FSS ratio.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Laser assisted heating of extreme ultraviolet-emitting z-pinch plasmas

A low-current and low-compression z-pinch nitrogen plasma is heated up by means of a short laser pulse. Spectra are taken in the extreme ultraviolet spectral range from 11 to 18 nm to estimate the heating effect. Without additional laser heating the initial plasma conditions are n{sub e}{approx_equal}10{sup 17} cm{sup -3} and T{sub e}{approx_equal}11 eV. The additional laser heating causes an increase in the electron temperature of about a factor of 5 to T{sub e}{approx_equal}57 eV, whereas the electron density nearly remains at the initial value. The experimentally determined values are compared to the results obtained by means of simulations and are in fairly good agreement.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Direct photoetching of polymers using radiation of high energy density from a table-top extreme ultraviolet plasma source

In order to perform material interaction studies with intense extreme ultraviolet (EUV) radiation, a Schwarzschild mirror objective coated with Mo/Si multilayers was adapted to a compact laser-driven EUV plasma source utilizing a solid Au target. By 10x demagnified imaging of the plasma a maximum pulse energy density of {approx}0.73 J/cm{sup 2} at a wavelength of 13.5 nm can be achieved in the image plane of the objective at a pulse duration of 8.8 ns. In this paper we present EUV photoetching rates measured for polymethyl methacrylate, polycarbonate, and polytetrafluoroethylene at various fluence levels. A linear dependence between etch depth and applied EUV pulse number could be observed without the necessity for any incubation pulses. By evaluating the slope of these data, etch rates were determined, revealing also a linear behavior for low fluences. A threshold energy density could not be observed. The slope of the linear etch regime as well as deviations from the linear trend at higher energy densities are discussed and compared to data known from deep UV laser ablation. Furthermore, the surface roughness of the structured polymers was measured by atomic force microscopy and compared to the nonirradiated polymer surface, indicating a rather smooth etch process (roughness increase of 20%-30%). The different shapes of the etch craters observed for the three polymers at high energy densities can be explained by the measured fluence dependence of the etch rates, having consequences for the proper use of polymer ablation for beam profiling of focused EUV radiation.

36 MATERIALS SCIENCE↗

Surface modification of organic polymer by dual action of extreme ultraviolet/visible-near infrared ultrashort pulses

We present the experimental evidence of structural surface modifications of poly(methyl methacrylate) (PMMA) caused by simultaneous action of extreme ultraviolet (XUV) ({approx}21 nm) and visible-near infrared (visible-NIR) (820/410 nm) ultrashort pulses. Although the fluence of each individual beam was far below the surface modification threshold, very efficient and specific material expansion was observed after irradiation of PMMA by more than {approx}20 shots of mixed XUV/visible-NIR radiation. As the XUV photons generate free charge carriers, absorption of the optical radiation dramatically increases, which heats up the material and further enhances the XUV induced damage to the polymer chain.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Adaptive spatially resolving detector for the extreme ultraviolet with absolute measuring capability

A spatially resolving detector for the extreme ultraviolet (XUV) and soft x-ray spectral region is presented. Principle of operation is conversion of XUV radiation to visible light by a scintillator crystal. Luminescence is detected using charge coupled device camera and imaging optics. Single layer and multilayer coatings are applied to match the system to different spectral regions of interest. Field of view and spatial resolution can be adapted to the application. Calibration of the system enables to absolutely measure in-band radiation flux on the scintillator. The setup is designed for the characterization and optimization of XUV sources and XUV optical systems. Measurements, carried out to characterize the focus in a soft x-ray microscope, are presented as an application example.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cold-target recoil-ion momentum spectroscopy for diagnostics of high harmonics of the extreme-ultraviolet free-electron laser light source at SPring-8

We have developed a cold-target recoil-ion momentum spectroscopy apparatus dedicated to the experiments using the extreme-ultraviolet light pulses at the free-electron laser facility, SPring-8 Compact SASE Source test accelerator, in Japan and used it to measure spatial distributions of fundamental, second, and third harmonics at the end station.

43 PARTICLE ACCELERATORS↗

Ionic debris measurement of three extreme ultraviolet sources

Generation of debris in extreme ultraviolet (EUV) light sources is an inherent and real threat to the lifetime of collection optics. Debris measurement of these sources is useful to enable source suppliers to estimate collector lifetime. At the Center for Plasma Material Interactions (CPMI) at the University of Illinois, an Illinois calibrated spherical sector electrostatic energy analyzer (ICE) was built to measure the ion debris flux in absolute units. In addition to ion flux, the detector is also capable of identifying different ion species present in the plasma utilizing energy-to-charge ratio discrimination. The lifetime of the collector optics is calculated using the measured ion flux. In the current investigation we compare the measurement of ion debris production in three different EUV sources: the Energetiq EQ-10M, the AIXUV-100, and the XTREME XTS 13-35. In the EQ-10M source, three angular measurements are coupled with three variations in operating pressure to measure consequent effects on debris production. These measurements reveal four predominant ion species in the energetic debris analysis: C{sup +}, Si{sup +}, Xe{sup +}, and Xe{sup 2+}. The amount of debris is reduced as pressure is increased. Various debris mitigation methods are implemented in the AIXUV-100 source and results reveal that four ion species are observed (Ar{sup +}, Xe{sup +}, Xe{sup 2+}, and W{sup +}), though there does not seem to be a dominant species. The first mitigation technique, backstreaming argon toward the source, reduces the amount of Ar{sup +}, Xe{sup 2+}, and W{sup +}, yet increases the amount of Xe{sup +} The increase in Xe{sup +} flux is explained based on charge exchange phenomena. The ICE machine was then attached 1.92 m away from the pinch of XTS 13-35 source, and placed at 25 deg. away from the normal line. The comparison of results reveals that the XTS 13-35 and the EQ-10M sources produced comparable amounts of energetic ion flux per watt of EUV light produced. The AIXUV-100 source generated more ion debris flux per watt of EUV light than the other two sources, though it should be noted that the AIXUV-100 source was capable of producing more than ten times the amount of EUV light power compared to any of the other sources.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Radiation damage resistance of AlGaN detectors for applications in the extreme-ultraviolet spectral range

We report on the fabrication of aluminum gallium nitride (AlGaN) Schottky-photodiode-based detectors. AlGaN layers were grown using metal-organic chemical vapor deposition (MOCVD) on Si(111) wafers. The diodes were characterized at a wavelength of 13.5 nm using a table-top extreme-ultraviolet (EUV) radiation source, consisting of a laser-produced xenon plasma and a Schwarzschild objective. The responsivity of the diodes was tested between EUV energies ranging from 320 nJ down to several picojoules. For low fluences, a linear responsivity of 7.14 mAs/J could be determined. Saturation starts at approximately 1 nJ, merging into a linear response of 0.113 mAs/J, which could be attributed to the photoeffect on the Au electrodes on top of the diode. Furthermore, degradation tests were performed up to an absolute dose of 3.3x10{sup 19} photons/cm{sup 2}. AlGaN photodiodes were compared to commercially available silicon-based photodetectors. For AlGaN diodes, responsivity does not change even for the highest EUV dose, whereas the response of the Si diode decreases linearly to {approx}93% after 2x10{sup 19} photons/cm{sup 2}.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Complementary ion and extreme ultra-violet spectrometer for laser-plasma diagnosis

Simultaneous detection of extreme ultra-violet (XUV) and ion emission along the same line of sight provides comprehensive insight into the evolution of plasmas. This type of combined spectroscopy is applied to diagnose laser interaction with a spray target. The use of a micro-channel-plate detector assures reliable detection of both XUV and ion signals in a single laser shot. The qualitative analysis of the ion emission and XUV spectra allows to gain detailed information about the plasma conditions, and a correlation between the energetic proton emission and the XUV plasma emission can be suggested. The measured XUV emission spectrum from water spray shows efficient deceleration of laser accelerated electrons with energies up to keV in the initially cold background plasma and the collisional heating of the plasma.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimization of a gas discharge plasma source for extreme ultraviolet interference lithography at a wavelength of 11 nm

In this work, we report about the optimization of the spectral emission characteristic of a gas discharge plasma source for high-resolution extreme ultraviolet (EUV) interference lithography based on achromatic Talbot self-imaging. The working parameters of the source are optimized to achieve a required narrowband emission spectrum and to fulfill the necessary coherence and intensity requirements. The intense 4f-4d transitions around 11 nm in a highly ionized (Xe{sup 8+}-Xe{sup 12+}) xenon plasma are chosen to provide the working wavelength. This allows us to increase the available radiation intensity in comparison with an in-band EUV xenon emission at 13.5 nm and opens up the possibility to strongly suppress the influence of the 5p-4d transitions at wavelengths between 12 and 16 nm utilizing a significant difference in conditions for optical thickness between 4f-4d and 5p-4d transitions. The effect is achieved by using the admixture of argon to the pinch plasma, which allows keeping the plasma parameters approximately constant while, at the same time, reducing the density of xenon emitters. It is demonstrated that with this approach it is possible to achieve a high intensity 11 nm EUV radiation with a bandwidth of 3%-4% without the use of multilayer mirrors or other additional spectral filters in the vicinity of the working wavelength. The achieved radiation parameters are sufficient for high-performance interference lithography based on the achromatic Talbot effect.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Internal frequency conversion extreme ultraviolet interferometer using mutual coherence properties of two high-order-harmonic sources

We report on an innovative two-dimensional imaging extreme ultraviolet (XUV) interferometer operating at 32 nm based on the mutual coherence of two laser high order harmonics (HOH) sources, separately generated in gas. We give the first evidence that the two mutually coherent HOH sources can be produced in two independent spatially separated gas jets, allowing for probing centimeter-sized objects. A magnification factor of 10 leads to a micron resolution associated with a subpicosecond temporal resolution. Single shot interferograms with a fringe visibility better than 30% are routinely produced. As a test of the XUV interferometer, we measure a maximum electronic density of 3x10{sup 20} cm{sup -3} 1.1 ns after the creation of a plasma on aluminum target.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of ion emission of an extreme ultraviolet generating discharge produced Sn plasma

The ion emission of a Sn-based discharge produced extreme ultraviolet producing plasma is characterized with the combined use of different time-of-flight techniques. An electrostatic ion spectrometer is employed to measure the average charge distribution of the emitted Sn ions. A dedicated Faraday cup configuration is used to measure the total ion flux from the source for different discharge energies. High-energy Sn ions emitted by the plasma with energies up to 100 keV have been identified. The number of high-energy ions increases for higher electrical input energy into the plasma while the signal associated with the expanding plasma ions does not show such dependence. The ion energy distribution for a bulk of detected ions is calculated based on the Faraday cup measurements and compared with theoretical plasma expansion dynamics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Influence of spot size on extreme ultraviolet efficiency of laser-produced Sn plasmas

We have investigated the spot size effects on the extreme ultraviolet conversion efficiency (CE) of CO{sub 2} laser-produced Sn plasmas. The estimated CE of the laser to 13.5 nm radiation, within a 2% bandwidth, using a 10.6 {mu}m CO{sub 2} laser with various pulse widths (25-55 ns) showed a double hump structure during a target-lens scan, where the CE is nearly 25% lower at the best focal position. Density analysis of the CO{sub 2} laser-produced plasma showed steep density gradients at the best focal position, and a reduction in CE at the best focal position, which is explained by the lack of efficient coupling between the laser and the plasma.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗