Search NASA⌕ Search

SEARCH · Search NASA

Results for “Field Arrays”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

SURVEYING THE DYNAMIC RADIO SKY WITH THE LONG WAVELENGTH DEMONSTRATOR ARRAY

This paper presents a search for radio transients at a frequency of 73.8 MHz (4 m wavelength) using the all-sky imaging capabilities of the Long Wavelength Demonstrator Array (LWDA). The LWDA was a 16-dipole phased array telescope, located on the site of the Very Large Array in New Mexico. The field of view of the individual dipoles was essentially the entire sky, and the number of dipoles was sufficiently small that a simple software correlator could be used to make all-sky images. From 2006 October to 2007 February, we conducted an all-sky transient search program, acquiring a total of 106 hr of data; the time sampling varied, being 5 minutes at the start of the program and improving to 2 minutes by the end of the program. We were able to detect solar flares, and in a special-purpose mode, radio reflections from ionized meteor trails during the 2006 Leonid meteor shower. We detected no transients originating outside of the solar system above a flux density limit of 500 Jy, equivalent to a limit of no more than about 10{sup -2} events yr{sup -1} deg{sup -2}, having a pulse energy density {approx}>1.5 x 10{sup -20} J m{sup -2} Hz{sup -1} at 73.8 MHz for pulse widths of about 300 s. This event rate is comparable to that determined from previous all-sky transient searches, but at a lower frequency than most previous all-sky searches. We believe that the LWDA illustrates how an all-sky imaging mode could be a useful operational model for low-frequency instruments such as the Low Frequency Array, the Long Wavelength Array station, the low-frequency component of the Square Kilometre Array, and potentially the Lunar Radio Array.

79 ASTRONOMY AND ASTROPHYSICS↗

DETECTING MASSIVE GRAVITONS USING PULSAR TIMING ARRAYS

At the limit of weak static fields, general relativity becomes Newtonian gravity with a potential field that falls off as inverse distance rather than a theory of Yukawa-type fields with a finite range. General relativity also predicts that the speed of disturbances of its waves is c, the vacuum light speed, and is non-dispersive. For these reasons, the graviton, the boson for general relativity, can be considered to be massless. Massive gravitons, however, are features of some alternatives to general relativity. This has motivated experiments and observations that, so far, have been consistent with the zero-mass graviton of general relativity, but further tests will be valuable. A basis for new tests may be the high sensitivity gravitational wave (GW) experiments that are now being performed and the higher sensitivity experiments that are being planned. In these experiments, it should be feasible to detect low levels of dispersion due to non-zero graviton mass. One of the most promising techniques for such a detection may be the pulsar timing program that is sensitive to nano-Hertz GWs. Here, we present some details of such a detection scheme. The pulsar timing response to a GW background with the massive graviton is calculated, and the algorithm to detect the massive graviton is presented. We conclude that, with 90% probability, massless gravitons can be distinguished from gravitons heavier than 3 x 10{sup -22} eV (Compton wavelength {lambda}{sub g} = 4.1 x 10{sup 12} km), if bi-weekly observation of 60 pulsars is performed for 5 years with a pulsar rms timing accuracy of 100 ns. If 60 pulsars are observed for 10 years with the same accuracy, the detectable graviton mass is reduced to 5 x 10{sup -23} eV ({lambda}{sub g} = 2.5 x 10{sup 13} km); for 5 year observations of 100 or 300 pulsars, the sensitivity is respectively 2.5 x 10{sup -22} ({lambda}{sub g} = 5.0 x 10{sup 12} km) and 10{sup -22} eV ({lambda}{sub g} = 1.2 x 10{sup 13} km). Finally, a 10 year observation of 300 pulsars with 100 ns timing accuracy would probe graviton masses down to 3 x 10{sup -23} eV ({lambda}{sub g} = 4.1 x 10{sup 13} km).

79 ASTRONOMY AND ASTROPHYSICS↗

Optical and x-ray characterization of the Daedalus ultrafast x-ray imager

The Daedalus ultrafast x-ray imager is the latest generation in Sandia’s hybrid CMOS detector family. With three frames along an identical line of sight, 1 ns minimum integration time, a higher full well than Icarus, and added features, Daedalus brings exciting new capabilities to diagnostic applications in inertial confinement fusion and high energy density science. In this work, we present measurements of time response, dynamic range, spatial uniformity, pixel cross-talk, and absolute x-ray sensitivity using pulsed optical and x-ray sources. Here, we report a measured 1.5 Me — full well, pixel sensitivity at 9.58 × 10 —7 V/e — , and an estimate of spatial uniformity at ~5% across the sensor array.

47 OTHER INSTRUMENTATION↗

The repeating fast radio burst FRB 121102: multi-wavelength observations and additional bursts

We report on radio and X-ray observations of the only known repeating Fast Radio Burst (FRB) source, FRB 121102. We have detected six additional radio bursts from this source: five with the Green Bank Telescope at 2 GHz, and one at 1.4 GHz with the Arecibo Observatory, for a total of 17 bursts from this source. All have dispersion measures consistent with a single value (∼559 pc cm{sup −3}) that is three times the predicted maximum Galactic contribution. The 2 GHz bursts have highly variable spectra like those at 1.4 GHz, indicating that the frequency structure seen across the individual 1.4 and 2 GHz bandpasses is part of a wideband process. X-ray observations of the FRB 121102 field with the Swift and Chandra observatories show at least one possible counterpart; however, the probability of chance superposition is high. A radio imaging observation of the field with the Jansky Very Large Array at 1.6 GHz yields a 5σ upper limit of 0.3 mJy on any point-source continuum emission. This upper limit, combined with archival Wide-field Infrared Survey Explorer 22 μm and IPHAS Hα surveys, rules out the presence of an intervening Galactic H ii region. We update our estimate of the FRB detection rate in the PALFA survey to be 1.1{sub −1.0}{sup +3.7}×10{sup 4} FRBs sky{sup −1} day{sup −1} (95% confidence) for peak flux density at 1.4 GHz above 300 mJy. We find that the intrinsic widths of the 12 FRB 121102 bursts from Arecibo are, on average, significantly longer than the intrinsic widths of the 13 single-component FRBs detected with the Parkes telescope.

79 ASTRONOMY AND ASTROPHYSICS↗

Successful Demonstration of an Electrostatic Actuated Microshutter System for Space Telescope Flight Missions

After developing magnetically actuated microshutter array sub-systems as a field object selector for the James Webb Space Telescope (JWST), a team at the NASA Goddard Space Flight Center (GSFC) focused on the development of electrostatically actuated microshutter arrays – Next Generation Microshutter Arrays (NGMSA). The demonstration described in this late news is for the first NGMSA array that performed shutter operations for telescope imaging and spectroscopy in space. The carrier telescope, the Next-Generation Far-UV Off Roland-circle Telescope for Imaging and Spectroscopy (NG-FORTIS), has been designed and produced by Prof. Stephan McCandliss and his team at Johns Hopkins University. NG-FORTIS was launched into space successfully.

M. J. Li↗

A physically unclonable function using NV diamond magnetometry and micromagnet arrays

A physically unclonable function (PUF) is an embedded hardware security measure that provides protection against counterfeiting. In this article, we present our work on using an array of randomly magnetized micrometer-sized ferromagnetic bars (micromagnets) as a PUF. We employ a 4μm thick surface layer of nitrogen-vacancy (NV) centers in diamond to image the magnetic field from each micromagnet in the array, after which we extract the magnetic polarity of each micromagnet using image analysis techniques. Finally, after evaluating the randomness of the micromagnet array PUF and the sensitivity of the NV readout, we conclude by discussing the possible future enhancements for improved security and magnetic readout.

Electromagnetism↗

Optical and electrical properties of silicon nanopillars

The electrical and optical properties of silicon nanopillars (Si NPs) are studied. Electron-beam lithography and reactive ion etching are used for the formation of ordered Si-NP arrays. The Si NPs with a diameter from 60 to 340 nm and a height from 218 to 685 nm are formed. The Si NPs are coated with a TiON{sup x} layer with a thickness of 8 nm for chemical and electrical passivation of the surface. Scanning electron microscopy and atomic-force microscopy are used to characterize the obtained structures. The Si-NP arrays acquire various colors when exposed to “bright-field” illumination. The spectra of reflection from the Si-NP arrays in the wavelength range 500–1150 nm are obtained.

36 MATERIALS SCIENCE↗

Single-sided lateral-field and phototransistor-based optoelectronic tweezers

Described herein are single-sided lateral-field optoelectronic tweezers (LOET) devices which use photosensitive electrode arrays to create optically-induced dielectrophoretic forces in an electric field that is parallel to the plane of the device. In addition, phototransistor-based optoelectronic tweezers (PhOET) devices are described that allow for optoelectronic tweezers (OET) operation in high-conductivity physiological buffer and cell culture media.

Ohta, Aaron↗

Validation of Computational Fluid Dynamics Simulations for Biological Performance Assessment in Hydropower units (Final Report)

The biological performance assessment (BioPA) toolset developed by Pacific Northwest National Laboratory (PNNL) estimates the relative biological performance of fish passage at a hydroelectric power turbine unit. The tool is based on the use of computational fluid dynamics (CFD) and fish biological response relationships. The recent release, BioPA-v3, is based on directly computed trajectory and collision of material Lagrangian particles using CFD simulation codes rather than the prior version that relies on Tecplot to compute streamtrace trajectories. Before modifying the toolset, a series of validation tests were performed at the various steps of modification in the toolset. Validation is a critical step of any numerical investigation that reflects the accuracy and reliability of the predicted results. It raises the confidence level of the user to use the modified version of the BioPA toolset. Several test cases were simulated and compared, where available, to observed data. The trajectory and collision of the small spherical and cylindrical particles in a water flume were compared to in-house experiments. The CFD predicted collision rate and flow field compared well with experimental observation for vane array and large cylinder as target bodies. Next, the CFD-predicted flow field and hydraulic performance of a laboratory-scale model of a Francis turbine was also successfully validated. Note that the trajectory of the particles is significantly affected by the flow field in such extreme conditions. In addition to the particle trajectories and flow field, the collision detection method employed in the CFD simulations was also successfully validated. The CFD predicted impact velocity, collision time, velocity, and trajectory of a sphere excellently matched with analytical value for a bouncing ball in the elastic collision. A similar approach was also tested and successfully validated for a collision of sphere with a 45° inclined plane. After successfully validating different cases, the BioPA toolset was modified to use direct output of the CFD prediction and the new version can be used in evaluating biological performance at hydroelectric turbines.

13 HYDRO ENERGY↗

Direct Alpha Spectrometry of Nuclear Fallout

Advanced instruments and methods are under development to allow direct alpha spectrometry of nuclear fallout debris near the point of collection, to support nuclear forensics (NF). New approaches are needed to support NF in order to accelerate the process for data generation and reduce the overall timeline for decision making. Fallout debris at short time periods following detonation can be difficult to work with for alpha spectrometry, due to the presence of intense beta radiation originating from significant quantities of high-activity fission products. Intense beta radiation can challenge traditional silicon-based high-resolution alpha spectrometers. Addressing this, single-crystal (sc) chemical vapor deposition (CVD) produced diamond semiconductors have been studied for use for alpha spectrometry for assaying nuclear fallout debris. Tests have been performed using scCVD sensors to assay a variety of actinide-bearing samples. Sample preparation, when done, has been limited to pulverization using a mechanical ball mill. To reduce measurement times, multi-chip arrays of scCVD diamond semiconductor have been developed in form factors suitable for field deployment in support of NF objectives. These arrays have been tested using high-beta-activity sol gel surrogate nuclear explosive debris (SNED) containing varying concentrations of uranium and plutonium. Results from the use of scCVD detectors with sol gel SNED will be presented.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

DEVELOPMENT OF CONTROLLED PITCH NANO ARRAYS FOR APPLICATION IN NANO SCALE BASED PROPORTIONAL COUNTERS

Proportional counters (PCs) are a type of gas-filled radiation detection device capable of distinguishing between a wide range of radiation types and energies. In this application, however, these devices are limited by high power consumption and high bias potentials required to operate in the proportional detection regime. Previous work performed with a single carbon nanotube (CNT) anode has shown that nanoscale-based PCs can operate at bias potentials of 10V rather than the 1000V range required for PCs. ''Proof of concept'' experiments with a single CNT as the anode exhibit a small detection volume and consequently required long count times (24 hrs). To make this a practical detector technology (i.e., decrease the count time), the effective detection volume has to be increased. Experimental data and electric field modeling show that if the pitch (spacing between individual nanotubes) of the arrays is too small, the electric field of the individual nanostructure will collapse and the nanoscale array will behaved as a single macro-scale field with the associated high bias potential required to reach the proportional region. Electric-field modeling of the affect of nanostructure pitch on the electric field distribution of these arrays predicted that a pitch of about two-and-a-times the height of the nanostructure was required to retain the nanoscale electric field. In this work, we report on the fabrication and electrical property testing of nanoscale arrays with a range of controlled pitches.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Improved stellarator permanent magnet designs through combined discrete and continuous optimizations

A common optimization problem in the areas of magnetized plasmas and fusion energy is the design of magnets to produce a given three-dimensional magnetic field distribution to high precision. When designing arrays of permanent magnets for stellarator plasma confinement, such problems have tens of thousands of degrees of freedom whose solutions, for practical reasons, should be constrained to discrete spaces. We perform a direct comparison between two algorithms that have been developed previously for this purpose, and demonstrate that composite procedures that apply both algorithms in sequence can produce substantially improved results. One approach uses a continuous, quasi-Newton procedure to optimize the dipole moments of a set of magnets and then projects the solution onto a discrete space. The second uses an inherently discrete greedy optimization procedure that has been enhanced and generalized for this work. Further, the approaches are both applied to design arrays cubic rare-Earth permanent magnets to confine a quasi-axisymmetric plasma with a magnetic field on axis of 0.5 T. The first approach tends to find solutions with higher field accuracy, whereas the second can find solutions with substantially (up to 30%) fewer magnets. When the approaches are combined, they can obtain solutions with magnet quantities comparable to the second approach while matching the field accuracy of the first.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

THE SPECTRAL ENERGY DISTRIBUTIONS OF z ∼ 8 GALAXIES FROM THE IRAC ULTRA DEEP FIELDS: EMISSION LINES, STELLAR MASSES, AND SPECIFIC STAR FORMATION RATES AT 650 MYR

Using new ultradeep Spitzer/InfraRed Array Camera (IRAC) photometry from the IRAC Ultra Deep Field program, we investigate the stellar populations of a sample of 63 Y-dropout galaxy candidates at z ∼ 8, only 650 Myr after the big bang. The sources are selected from HST/ACS+WFC3/IR data over the Hubble Ultra Deep Field (HUDF), two HUDF parallel fields, and wide area data over the CANDELS/GOODS-South. The new Spitzer/IRAC data increase the coverage in [3.6] and [4.5] to ∼120h over the HUDF reaching depths of ∼28 (AB,1σ). The improved depth and inclusion of brighter candidates result in direct ≥3σ InfraRed Array Camera (IRAC) detections of 20/63 sources, of which 11/63 are detected at ≥5σ. The average [3.6]-[4.5] colors of IRAC detected galaxies at z ∼ 8 are markedly redder than those at z ∼ 7, observed only 130 Myr later. The simplest explanation is that we witness strong rest-frame optical emission lines (in particular [O III] λλ4959, 5007 + Hβ) moving through the IRAC bandpasses with redshift. Assuming that the average rest-frame spectrum is the same at both z ∼ 7 and z ∼ 8 we estimate a rest-frame equivalent width of contributing 0.56{sup +0.16}{sub -0.11} mag to the [4.5] filter at z ∼ 8. The corresponding W{sub Hα}=430{sup +160}{sub -110} Å implies an average specific star formation rate of sSFR=11{sub -5}{sup +11} Gyr{sup –1} and a stellar population age of 100{sub -50}{sup +100} Myr. Correcting the spectral energy distribution for the contribution of emission lines lowers the average best-fit stellar masses and mass-to-light ratios by ∼3 ×, decreasing the integrated stellar mass density to ρ{sup *}(z=8,M{sub UV}<-18)=0.6{sup +0.4}{sub -0.3}×10{sup 6} M{sub sun} Mpc{sup –3}.

79 ASTRONOMY AND ASTROPHYSICS↗

Design of a Ferroelectric Programmable Logic Gate Array

A programmable logic gate array has been designed utilizing ferroelectric field effect transistors. The design has only a small number of gates, but this could be scaled up to a more useful size. Using FFET's in a logic array gives several advantages. First, it allows real-time programmability to the array to give high speed reconfiguration. It also allows the array to be configured nearly an unlimited number of times, unlike a FLASH FPGA. Finally, the Ferroelectric Programmable Logic Gate Array (FPLGA) can be implemented using a smaller number of transistors because of the inherent logic characteristics of an FFET. The device was only designed and modeled using Spice models of the circuit, including the FFET. The actual device was not produced. The design consists of a small array of NAND and NOR logic gates. Other gates could easily be produced. They are linked by FFET's that control the logic flow. Timing and logic tables have been produced showing the array can produce a variety of logic combinations at a real time usable speed. This device could be a prototype for a device that could be put into imbedded systems that need the high speed of hardware implementation of logic and the complexity to need to change the logic algorithm. Because of the non-volatile nature of the FFET, it would also be useful in situations that needed to program a logic array once and use it repeatedly after the power has been shut off.

MacLeod, Todd C.↗

Modeling Progressive Failure of Bonded Joints Using a Single Joint Finite Element

Enhanced finite elements are elements with an embedded analytical solution which can capture detailed local fields, enabling more efficient, mesh-independent finite element analysis. In the present study, an enhanced finite element is applied to generate a general framework capable of modeling an array of joint types. The joint field equations are derived using the principle of minimum potential energy, and the resulting solutions for the displacement fields are used to generate shape functions and a stiffness matrix for a single joint finite element. This single finite element thus captures the detailed stress and strain fields within the bonded joint, but it can function within a broader structural finite element model. The costs associated with a fine mesh of the joint can thus be avoided while still obtaining a detailed solution for the joint. Additionally, the capability to model non-linear adhesive constitutive behavior has been included within the method, and progressive failure of the adhesive can be modeled by using a strain-based failure criteria and re-sizing the joint as the adhesive fails. Results of the model compare favorably with experimental and finite element results.

Stapleton, Scott E.↗

Studies of penetration of the magnetic field into electrically imploded loads in the Angara-5-1 facility

Results are presented from measurements of the distributions of the azimuthal magnetic field in aluminum, copper, molybdenum, tungsten and other wire arrays electrically imploded at currents of up to 3 MA in the Angara-5-1 facility. It is shown that the time during which the magnetic field of the current pulse reaches the array axis depends on the material of the wires or wire coating. The current of the precursor formed on the array axis before the implosion of the main load mass is measured. It is shown that the penetration of the load material with the frozen-in magnetic field into a polymer (agar-agar) foam liner is drastically different from that in the case of a wire array. It is found that the rate of current transfer to the array axis is maximum for tungsten wire arrays. The rates of plasma production during implosion of loads made of different materials are compared.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

IDENTIFICATION OF TWO BRIGHT z > 3 SUBMILLIMETER GALAXY CANDIDATES IN THE COSMOS FIELD

We present high-resolution interferometric Submillimeter Array imaging at 890 {mu}m ({approx}2'' resolution) of two millimeter selected galaxies-MMJ100015+021549 and MMJ100047+021021-discovered with the Max-Planck Millimeter Bolometer (MAMBO) on the IRAM 30 m telescope and also detected with Bolocam on the CSO, in the COSMOS field. The first source is significantly detected at the {approx}11{sigma} level, while the second source is tentatively detected at the {approx}4{sigma} level, leading to a positional accuracy of {approx}0.''2-0.''3. MM100015+021549 is identified with a faint radio and K-band source. MMJ100047+021021 shows no radio emission and is tentatively identified with a very faint K-band peak which lies at {approx}1.''2 from a clumpy optical source. The submillimeter-to-radio flux ratio for MM100015+021549 yields a redshift of {approx}4.8, consistent with the redshift implied by the UV-to-submillimeter photometry, z {approx} 3.0-5.0. We find evidence for warm dust in this source with an infrared luminosity in the range {approx}(0.9-2.5) x 10{sup 13} L{sub sun}, supporting the increasing evidence for a population of luminous submillimeter galaxies at z > 3. Finally, the lack of photometric data for MMJ100047+021021 does not allow us to investigate its properties in detail; however, its submillimeter-to-radio flux ratio implies z > 3.5.

79 ASTRONOMY AND ASTROPHYSICS↗

Gauge-potential-induced vortices in spin-1 Bose–Einstein condensates with spin–orbit coupling

Highlights: •Effectively rotate the so-coupled condensate by an external magnetic field. •New effects of the Aharonov–Bohm geometric phase in ultracold atomic gases. •Many novel vortex structures have been studied. •A new stabilization mechanism for multiquantum vortices in spinor BECs. -- Abstract: We investigate the vortex states generated by the gauge-potential-induced rotation in spin-1 Bose–Einstein condensates with spin–orbit coupling. An external magnetic field coupling with spin equivalently imprints a non-zero gauge angular momentum, which induces an equivalent canonical angular momentum in the opposite direction, accompanied by the generation of quantized vortices. The competition between interatomic interactions, spin–orbit coupling and magnetic field leads to a variety of vortex structures. In the weakly interatomic interacting regime, as the increase of SO coupling strength, the condensate with a weak magnetic field gradient experiences the transition from polar-core vortex to Mermin–Ho vortex then to vortex cluster , and the three-vortex structures are found in the vortex cluster. As the SO coupling increases further, the condensate presents symmetrical density domains separated by radial vortex arrays. With the increase of magnetic field gradient, the number of density domains increases, and the condensate eventually turns into a giant vortex. In the relatively strong interatomic interacting regime, vortex sheets are formed when the magnetic field gradient is weak, and the increasing of magnetic field gradient makes the vortex arrangement orderly. Compared with the cases of weak interatomic interacting regime, density domain structures are broken because of the strong interatomic interactions, and the vortices are arranged in coaxial annular arrays.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗