Search NASA⌕ Search

SEARCH · Search NASA

Results for “Hourly data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

Seismic Survey 2016 Data at Crescent Valley, Nevada

In September 2016, 989 vertical-component seismic instruments were deployed for 75 hours at the Crescent Valley greenfield geothermal play area in Nevada. Data were recorded 12/9/16 - 12/15/16. Data are stored in individual files in one-minute increments in SEGD formats. See the metadata in Crescent Valley Station Locations.sp1, Crescent Valley Observer Logs.xls, and the attached Metadata link for details about the seismic station locations, seismic data logger specifications, instrumentation specifications, descriptions of data, a fracture finding summary, and the final report for the 2016 seismic survey done in Crescent Valley, Nevada. Note that no discrete events were identified, and a 1750m x 2250m x 300m PSET volume of acoustic energy was delivered.

15 GEOTHERMAL ENERGY↗

Features of steady magnetospheric convection

The large-scale patterns of ionospheric convection and particle precipitation are described during two intervals of steady magnetospheric convection (SMC) on November 24, 1981. The unique data set used in the analysis includes recordings from the worldwide network of magnetometers and all-sky cameras, global auroral images from the Dynamics Explorer (DE) 1 spacecraft, and particle precipitation data from low-altitude National Oceanic and Atmospheric Administration (NOAA) 6 and NOAA 7 spacecraft. The data show that intense magnetospheric convection continued during more than 10 hours under the steady southward interplanetary magnetic field without any distinct substorm signatures. All data sets available confirmed the stable character of the large-scale magnetospheric configuration during this period. In particular, the magnetic flux threading the polar cap was stable (within 10%) during 3.5 hours of continued DE 1 observations. The dayside cusp was located at an unusually low latitude (70 deg CGL). The nightside auroral pattern consisted of two distinct regions. The diffuse aurora in the equatorward half of the expanded (10 deg wide) auroral oval was well-separated from the bright, active auroral forms found in the vicinity of the poleward boundary of the oval. The twin-vortex convection pattern had no signature of the Harang discontinuity; its nightside 'convection throat' was spatially coincident with the poleward active auroras. This region of the auroral oval was identified as the primary site of the short-lived transient activations during the SMC intervals. The energetic particle observations show that the auroral precipitation up to its high-latitude limit is on closed field lines and that particle acceleration up to greater than 30-keV energy starts close to this limit. The isotropic boundaries of the greater than 30-keV protons and electrons were found close to each other, separating regions of discrete and diffuse precipitation. This suggests that these precipitation types originate on the very taillike and very dipolelike field lines, respectively.

Yahnin, A.↗

The Advanced Global Atmospheric Gases Experiment (AGAGE) Data

In the ALE/GAGE/AGAGE global network program, continuous high frequency gas chromatographic measurements of four biogenic/anthropogenic gases (methane, CH4; nitrous oxide, N2O; hydrogen, H2; and carbon monoxide, CO) and several anthropogenic gases that contribute to stratospheric ozone destruction and/or to the greenhouse effect have been carried out at five globally distributed sites for several years. The program, which began in 1978, is divided into three parts associated with three changes in instrumentation: the Atmospheric Lifetime Experiment (ALE), which used Hewlett Packard HP5840 gas chromatographs; the Global Atmospheric Gases Experiment (GAGE), which used HP5880 gas chromatographs; and the present Advanced GAGE (AGAGE). AGAGE uses two types of instruments: a gas chromatograph with multiple detectors (GC-MD), and a gas chromatograph with mass spectrometric analysis (GC-MS). Beginning in January 2004, an improved cryogenic preconcentration system (Medusa) replaced the absorption-desorption module in the GC-MS systems at Mace Head and Cape Grim; this provided improved capability to measure a broader range of volatile perfluorocarbons with high global warming potentials. The Medusa GC-MS systems were subsequently used at other AGAGE stations (Trinidad Head, Barbados, American Samoa, Zeppelin, Jungfraujoch, and Goan) after the initial setup at Mace Head and Cape Grim. More information may be found at the AGAGE home page: https://agage.mit.edu/instruments.Compared to the previous version (https://data.ess-dive.lbl.gov/datasets/doi: doi:10.15485/1781803), the latest update (Agage_gcmd_gcms.data.2022_01_03.tar.gz) includes 6 months of new data through the end of September 2020. For a complete list of released compounds and used standard scales, please see “AGAGE_scale_2021_v1.pdf” file. Additional information can also be found on the AGAGE website (https://agage.mit.edu).

54 ENVIRONMENTAL SCIENCES↗

Potential impact of remote sensing data on sea-state analysis and prediction

The severe North Atlantic storm which damaged the ocean liner Queen Elizabeth 2 (QE2) was studied to assess the impact of remotely sensed marine surface wind data obtained by SEASAT-A, on sea state specifications and forecasts. Alternate representations of the surface wind field in the QE2 storm were produced from the SEASAT enhanced data base, and from operational analyses based upon conventional data. The wind fields were used to drive a high resolution spectral ocean surface wave prediction model. Results show that sea state analyses would have been vastly improved during the period of storm formation and explosive development had remote sensing wind data been available in real time. A modest improvement in operational 12 to 24 hour wave forecasts would have followed automatically from the improved initial state specification made possible by the remote sensing data in both numerical and sea state prediction models. Significantly improved 24 to 48 hour wave forecasts require in addition to remote sensing data, refinement in the numerical and physical aspects of weather prediction models.

Cardone, V. J.↗

Comparisons of Monthly Oceanic Rainfall Derived from TMI and SSM/I

A technique for estimating monthly oceanic rainfall rate using multi-channel microwave measurements has been developed. There are three prominent features of this algorithm. First, the knowledge of the form of the rainfall intensity probability density function used to augment the measurements. Second, utilizing a linear combination of the 19.35 and 22.235 GHz channels to de-emphasize the effect of water vapor. Third, an objective technique has been developed to estimate the rain layer thickness from the 19.35 and 22.235 GHz brightness temperature histograms. This technique is applied to the SSM/I data since 1987 to infer monthly rainfall for the Global Precipitation Climatology Project (GPCP). A modified version of this algorithm is now being applied to the TRMM Microwave Imager (TMI) data. TMI data with better spatial resolution and 24 hour sampling (vs. sun-synchronized sampling, which is limited to two narrow intervals of local solar time for DMSP satellites) prompt us to study the similarity and difference between these two rainfall estimates. Six months of rainfall data (January to June 1998) are used in this study. Means and standard deviations are calculated. Paired student t-tests are administrated to evaluate the differences between rainfall estimates from SSM/I and TMI data. Their differences are discussed in the context of global satellite rainfall estimation.

Chang, A. T. C.↗

Monthly Oceanic Rainfall Derived from Space-Borne Microwave Data

A technique for estimating monthly oceanic rainfall rate using multi-channel microwave measurements has been developed. This technique is applied to the Special Sensor Microwave Imager (SSM/I) data since 1987 to infer monthly rainfall for the Global Precipitation Climatology Project (GPCP). A modified version of this algorithm is now being applied to the TRMM Microwave Imager (TMI) data. There are three prominent features of this algorithm. First, the knowledge of the form of the rainfall intensity probability density function used to augment the measurements. Second, utilizing a linear combination of the 19.35 and 22.235 GHz channels to deemphasize the effect of water vapor. Third, an objective technique has been developed to estimate the rain layer thickness from the 19.35 and 22.23 5 GHz brightness temperature histograms, TMI data with better spatial resolution and 24 hour sampling (vs. sun-synchronized sampling, which is limited to two narrow intervals of local solar time for DMSP satellites) prompt us to study the similarity and difference between these two rainfall estimates. One year of rainfall data (January to December 1998) are used in this study. The mean differences of these two rain estimates are typically less than 15%. Statistical tests are administrated to evaluate the differences between rainfall estimates from SSM/I and TMI data. Differences between TMI and SSM/I rain estimates are discussed in the context of radiative transfer calculations and rainfall estimate algorithm.

Chang, Alfred T. C.↗

Application of the BSRN Data in Validating the GEWEX SRB Data: Quality-Control and Resulting Available Monthly Means

The BSRN data have been used in validation of the satellite-based GEWEX SRB data, and the recent Release 4.0-IP data cover the 34-year period from July 1983 to June 2017. Here we focus on the validation of the shortwave monthly means from 1992 to 2017 against the BSRN Global 1. We first perform the BSRN-recommended quality-control on the original data. We then calculate the monthly-hourly means from which we calculate the monthly means. Twenty-four (24) monthly-hourly means are required to calculate a monthly mean. To guarantee the quality of the monthly mean, we also require that 95% or more hourly means be available in order for a monthly-hourly mean to be calculated. Since the above quality-control significantly reduces the number of available monthly means, we are curious how many monthly means we would get if we relax the quality-control, and how the resulting monthly means would compare with the GEWEX SRB data. In a version we experimented, only constant upper and lower bounds are imposed on various fluxes, and the original data are largely retained. We found that many more monthly means would be available, and the overall bias and RMS would not be significantly different from that of the strict quality-control. With the strict quality-control, if we let Avail (minimum percentage of available hourly means required for a monthly-hourly mean to be computed) change from 3.2% to 95%, the Bias/RMS/N change from -2.77/20.56/9756 to -0.35/13.41/4581, where N is the number of available monthly means, and Bias and RMS are in the unit of W/sq. m. On the other hand, with the lax quality-control, when Avail changes from 3.2% to 95%, the Bias/RMS/N change from -0.82/19.53/9819 to -0.21/14.41/5875. South Pole (SPO) is one of the sites we are particularly interested in. With the strict quality-control, and when Avail changes from 3.2% to 95%, the Bias/RMS/N change from 5.89/15.85/283 to 1.23/5.52/133; with the lax quality-control, the Bias/RMS/N change from 1.17/11.21/284 to 1.88/7.9/177.

Taiping Zhang↗

In-situ measurements of chemically and radiatively important atmospheric gases from the Advanced Global Atmospheric Gas Experiment (AGAGE) and affiliated stations.

In the ALE/GAGE/AGAGE global network program, continuous high frequency gas chromatographic measurements of four biogenic/anthropogenic gases (methane, CH4; nitrous oxide, N2O; hydrogen, H2; and carbon monoxide, CO) and several anthropogenic gases that contribute to stratospheric ozone destruction and/or to the greenhouse effect have been carried out at five globally distributed sites for several years. The program, which began in 1978, is divided into three parts associated with three changes in instrumentation: the Atmospheric Lifetime Experiment (ALE), which used Hewlett Packard HP5840 gas chromatographs; the Global Atmospheric Gases Experiment (GAGE), which used HP5880 gas chromatographs; and the present Advanced GAGE (AGAGE). AGAGE uses two types of instruments: a gas chromatograph with multiple detectors (GC-MD), and a gas chromatograph with mass spectrometric analysis (GC-MS). Beginning in January 2004, an improved cryogenic preconcentration system (Medusa) replaced the absorption-desorption module in the GC-MS systems at Mace Head and Cape Grim; this provided improved capability to measure a broader range of volatile perfluorocarbons with high global warming potentials. The Medusa GC-MS systems were subsequently used at other AGAGE stations (Trinidad Head, Barbados, American Samoa, Zeppelin, Jungfraujoch, and Goan) after the initial setup at Mace Head and Cape Grim. More information may be found at the AGAGE home page: https://agage.mit.edu/instruments.Compared to the previous version (https://data.ess-dive.lbl.gov/view/doi:10.3334/CDIAC/ATG.DB1001), the latest update (Agage_gcmd_gcms_data_2021_04_07_tar.gz) includes 6 months of new data through the end of March 2020. Two new compounds, HCFC-132b, and HCFC-133a, are also included in this version. For a complete list of released compounds and used standard scales, please see “AGAGE_scale_2021_v1.pdf” file. Additional information can also be found on the AGAGE website (https://agage.mit.edu).

54 ENVIRONMENTAL SCIENCES↗

Plans for a fast image recording system at ESO

A 256 diode-array will be installed as detector on the ESO OPTRONICS S-3000 measuring machine in order to increase the acquisition rate. A high intensity LED will be used as light source in a pulse mode. The data will be stored on a random access mass storage device as density values for later education. The scanning time for a 30 cm x 30 cm plate with a step size of 10 micron will be less than 10 hours while the dynamic range of the data is expected to be 2.5 density units with an offset of at least 1 unit.

Grosboel, P. J.↗

Applications of ERTS-A Data Collection System (DCS) in the Arizona Regional Ecological Test Site (ARETS)

The author has identified the following significant results. Preliminary analysis of DCS data from the USGS Verde River stream flow measuring site indicates the DCS system is furnishing high quality data more frequently than had been expected. During the 43-day period between Nov. 3, and Dec. 15, 1972, 552 DCS transmissions were received during 193 data passes. The amount of data received far exceeded the single high quality transmission per 12-hour period expected from the DCS system. The digital-parallel ERTS-1 data has furnished sufficient to accurately compute mean daily gage heights. These in turn, are used to compute average daily streamflow rates during periods of stable or slowly changing flow conditions. The digital-parallel data has also furnished useful information during peak flow periods. However, the serial-digital DCS capability, currently under development for transmitting streamflow data, should provide data of greater utility for determining times of flood peaks.

Schumann, H. H.↗

Global circuit variability from multiple stratospheric electrical measurements

The vertical component of the electric field, conductivity, and the derived current density from eight superpressure balloons are examined. Special emphasis was placed on the fair-weather, simultaneous measurements from widely spaced constant-altitude (26 km) balloons. The conductivity measurements were well organized by a simple ionization rate parameterization depending on the geomagnetic latitude. The variability of all the electrical parameters was found to be independent of the balloon separation. Much of the time the current density measurements were within 20 percent, for simultaneous flights, even though the balloons were up to 6000 km apart. Also, these simultaneous current density data show that the global current source was significantly variable on hourly and daily time scales. Finally, the use of the simultaneous current density data is discussed as a possible 'geoelectric index'. Advantages and limitations of such an index are discussed.

Norville, Kent↗

Construction of a Matched Global Cloud and Radiance Product from LEO/GEO and EPIC Observations to Estimate Daytime Earth Radiation Budget from DSCOVR

With the launch of the Deep Space Climate Observatory (DSCOVR), new estimates of the daytime Earth radiation budget can be computed from a combination of measurements from the two Earth-observing sensors onboard the spacecraft, the Earth Polychromatic Imaging Camera (EPIC) and the National Institute of Standards and Technology Advanced Radiometer (NISTAR). Although these instruments can provide accurate top-of-atmosphere (TOA) radiance measurements, they lack sufficient resolution to provide details on small-scale surface and cloud properties. Previous studies have shown that these properties have a strong influence on the anisotropy of the radiation at the TOA, and ignoring such effects can result in large TOA-flux errors. To overcome these effects, high-resolution scene identification is needed for accurate Earth radiation budget estimation. Selected radiance and cloud property data measured and derived from several low earth orbit (LEO, including NASA Terra and Aqua MODIS, NOAA AVHRR) and geosynchronous (GEO, including GOES (east and west), METEOSAT, INSAT-3D, MTSAT-2, and HIMAWARI-8) satellite imagers were collected to create hourly 5-km resolution global composites of data necessary to compute angular distribution models (ADM) for reflected shortwave (SW) and longwave (LW) radiation. The satellite data provide an independent source of radiance measurements and scene identification information necessary to construct ADMs that are used to determine the daytime Earth radiation budget. To optimize spatial matching between EPIC measurements and the high-resolution composite cloud properties, LEO/GEO retrievals within the EPIC fields of view (FOV) are convolved to the EPIC point spread function (PSF) in a similar manner to the Clouds and the Earth's Radiant Energy System (CERES) Single Scanner Footprint TOA/Surface Fluxes and Clouds (SSF) product. Examples of the merged LEO/GEO/EPIC product will be presented, describing the chosen radiance and cloud properties and details of how data from the multi-satellite measurements are selected.

Duda, David P.↗

Comparative study of the cooling energy performance of variable refrigerant flow systems and variable air volume systems in office buildings

Variable air volume (VAV) and variable refrigerant flow (VRF) systems are widely used in office buildings. This study investigated VAV and VRF systems in five typical office buildings in China, and compared their cooling energy use. Site survey and field measurements were conducted to collect the data of building characteristics and operation. Measured cooling electricity use was collected from sub-metering in the five buildings. The sub-metering data normalized by climate and operating hours indicated that the cooling energy consumed by VRF systems was up to 70% lower than that consumed by VAV systems. This was mainly because of the different operation modes of both system types that led to significantly fewer operating hours for the VRF systems. Building simulations were used to quantify the impact of operation modes of VRF and VAV systems on cooling loads. A prototype office building in China was used as the model. The simulation results showed that the VRF operation mode required much lower cooling load when compared to the VAV operation mode. For example, the cooling loads decreased by 42% in Hong Kong and 53% in Qingdao. Key findings include the following: the VRF systems operated in the part-time-part-space mode enabling occupants to turn on the air-conditioning only when needed and when the spaces were occupied. However, the VAV systems operated in the full-time-full-space mode limiting occupants’ control of operation. These findings provide insights into VRF systems operation and controls as well as their energy performance, which could help guide HVAC designers on system selection and building operators or facility managers on system operations to achieve low- or zero-net energy buildings.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

24-hour human urine and serum profiles of Bisphenol A following ingestion in soup: Individual pharmacokinetic data and emographics

Here we present data to evaluate potential absorption of Bisphenol A through non-metabolizing tissues of the upper digestive tract. Concurrent serum and urine concentrations of d6-BPA, and its glucuronide and sulfate conjugates, were measured over a 24 h period in 10 adult male volunteers following ingestion of 30 μg d6-BPA/kg body weight in soup. The pharmacokinetic behavior of BPA and its metabolites in this cohort (rapid absorption, complete elimination, evidence against sublingual absorption) was reported. This Data in Brief article contains the corresponding individual pharmacokinetic data, reports the demographics of the cohort and provides additional details related to the analytical methods employed and is related to [4].

59 BASIC BIOLOGICAL SCIENCES↗

A spatially based area–time inundation index model developed to assess habitat opportunity in tidal–fluvial wetlands and restoration sites

The hydrodynamics of tidal wetland areas in the lower Columbia River floodplain and estuary directly affect habitat opportunity for endangered salmonid fishes. Physical and biological structures and functions in the system are directly affected by inundation patterns influenced by tidal cycles, hydropower operations, river discharge, upriver water withdrawals, climate, and physical barriers such as dikes, culverts, and tide gates. Ongoing ecosystem restoration efforts are intended to increase the opportunity for salmon to access beneficial habitats by hydrologically reconnecting main-stem river channels and diked areas within the historical floodplain. To address the need to evaluate habitat opportunity, a geographic information system-based Area-Time Inundation Index Model (ATIIM) was developed. Additionally, the ATIIM integrates in situ or modeled hourly water-surface elevation (WSE) data and advanced terrain processing of high-resolution elevation data. The ATIIM uses a spatially based wetted-area algorithm to determine site average bankfull elevation, two- and three-dimensional inundation extent, and other site metrics. Hydrological process metrics such as inundation frequency, duration, maximum area, and maximum frequency area can inform evaluation of proposed restoration sites; e.g., determine trade-offs between WSE and habitat opportunity, contrast alternative restoration designs, predict impacts of altered flow regimes, and estimate nutrient and biomass fluxes. In an adaptive management framework, this model can be used to provide standardized site comparisons and effectiveness monitoring of changes in the developmental trajectories of restoration sites. Overall, results are presented for 11 wetlands representative of tidal marshes, tidal forested wetlands, and restoration sites.

42 ENGINEERING↗

Field test and simulation evaluation of variable refrigerant flow systems performance

Our study aims to compare the performance of a Variable Refrigerant Flow (VRF) system with a Roof Top Unit, (RTU) and a variable-air-volume (VAV) system through field tests and energy simulations. The field test was conducted in as similar conditions as possible between the two systems, such as the installation and operating environments of heating, the ventilation and air conditioning (HVAC) system, including internal heat gain and outdoor conditions, including buildings to compare the performance of the two systems accurately. A VRF system and RTU were installed at the test building located in Oak Ridge, Tennessee, in the USA. The same internal heat gain was generated at the same operating time of the two systems using lighting, electric heaters, and humidifiers inside the building. The HVAC system was alternately operated between cooling and heating operations to acquire energy performance data and to compare energy usage. Furthermore, an hourly building energy simulation model was developed with regard to the VRF system and RTU, and then the model was calibrated using actual measured data. Then, annual energy consumption of the two systems were compared and analyzed using the calibrated model. Moreover, additional analysis was conducted when the controlled discharge air temperature in the RTU was changed. The field test result showed that when energy consumptions of two systems were compared at the same outdoor conditions, using the weather-normalized model, the VRF system exhibited an energy reduction of approximately 17% during cooling operation and of approximately 74% during heating operations. A comparison on the annual energy consumption using simulations showed that the VRF system reduced energy consumption more than that of the RTU by 60%. Furthermore, when the discharge air temperature in the RTU was controlled according to the outdoor air temperature, energy consumption of the RTU was reduced by 6% in cooling operations and by 18% in heating operation. As a result, energy consumption of the VRF system was reduced by more than that of the RTU by 55% approximately.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Pregnancy exposure to wind turbine noise and adverse birth outcomes: a nationwide cohort study

Highlights: • We identified all Danes exposed to wind turbine noise (WTN) from 1982 to 2013. • We then identified all live born singletons from mothers in this population. • We investigated preterm birth, low birth weight and small for gestational age. • We found no associations between WTN and the adverse birth outcomes. • Few women had high levels of WTN and independent replication is called for. Noise from wind turbines (WTs) is reported as more annoying than traffic noise at similar levels, raising concerns as to whether WT noise (WTN) may negatively affect health, as reported for traffic noise. We aimed to investigate whether residential WTN is associated with adverse birth outcomes. Based on national registries, we identified all Danish dwellings situated within ≤ 20 wt heights radius and a random selection of 25% of dwellings situated within 20–40 wt heights radius of a WT. We identified 135,795 pregnant women living in the dwellings from 1982 to 2013, and collected information on gestational age and birth weight from a national birth registry. Using data on WT type and simulated hourly wind at each WT, we estimated hourly outdoor and low frequency (LF) indoor WTN at the dwellings of the pregnant women and aggregated as mean nighttime WTN during pregnancy. We used logistic regression with adjustment for individual and area-level covariates for the analyses. We did not find evidence suggesting that mean pregnancy or trimester-specific exposure to outdoor or indoor LF WTN were associated with any of the three adverse birth outcomes investigated: preterm birth (n = 13,003), term small for gestational age (n = 12,220) or term low birth weight (n = 1127). However, the number of cases in the highest exposure categories of ≥ 42 dB outdoor WTN or ≥ 15 dB indoor LF WTN were low for all outcomes (n between 0 and 31). The present study does not support an association between nighttime WTN and adverse birth outcomes. However, there were few cases in the high exposure groups and the results call for reproduction.

54 ENVIRONMENTAL SCIENCES↗