Search NASA⌕ Search

SEARCH · Search NASA

Results for “IRRADIATION DEVICES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

Morphologies of tungsten nanotendrils grown under helium exposure

Nanotendril “fuzz” will grow under He bombardment under tokamak-relevant conditions on tungsten plasma-facing materials in a magnetic fusion energy device. We have grown tungsten nanotendrils at low (50 eV) and high (12 keV) He bombardment energy, in the range 900–1000 °C, and characterized them using electron microscopy. Low energy tendrils are finer (~22 nm diameter) than high-energy tendrils (~176 nm diameter), and low-energy tendrils have a smoother surface than high-energy tendrils. Cavities were omnipresent and typically ~5–10 nm in size. Oxygen was present at tendril surfaces, but tendrils were all BCC tungsten metal. Electron diffraction measured tendril growth axes and grain boundary angle/axis pairs; no preferential growth axes or angle/axis pairs were observed, and low-energy fuzz grain boundaries tended to be high angle; high energy tendril grain boundaries were not observed. We speculate that the strong tendency to high-angle grain boundaries in the low-energy tendrils implies that as the tendrils twist or bend, strain must accumulate until nucleation of a grain boundary is favorable compared to further lattice rotation. Finally, the high-energy tendrils consisted of very large (>100 nm) grains compared to the tendril size, so the nature of the high energy irradiation must enable faster growth with less lattice rotation.

36 MATERIALS SCIENCE↗

High-output-power densities from molecular beam epitaxy grown n- and p-type PbTeSe-based thermoelectrics via improved contact metallization

Electrical power densities of up to 33 W/cm{sup 2} and up to 12 W/cm{sup 2} were obtained for n-type and p-type PbTeSe-based stand-alone thermoelectric devices, respectively, at modest temperature gradients of {approx}200 deg. C (T{sub cold}= 25 deg. C). These large power densities were enabled by greatly improving electrical contact resistivities in the thermoelectric devices. Electrical contacts with contact resistivities as low as 3.9 x 10{sup -6}{Omega} cm{sup 2} and 4.0 x 10{sup -6}{Omega} cm{sup 2} for n- and p-type telluride-based- materials, respectively, were developed by investigating several metallization schemes and contact layer doping/alloy combinations, in conjunction with a novel contact application process. This process exposes heated semiconductor surfaces to an atomic hydrogen flux under high vacuum for surface cleaning (oxide and carbon removal), followed immediately by an in-situ electron-beam evaporation of the metal layers.

36 MATERIALS SCIENCE↗

Overview of the Salt at Wall Thermal Exchanges (SWATH) Experiment

Molten Salt Reactors have attracted increased attention in recent years because of the design and safety possibilities offered by the use of a liquid fuel. The European project SAMOFAR1 (2015-2019) is currently coordinating the research efforts on the Molten Fast Salt Reactor (MSFR) concept in Europe. The MSFR is a fast-spectrum breeder reactor with a large negative power coefficient that can be operated in a Thorium fuel cycle. The fast spectrum allows the reduction of the reprocessing requirements and a better reactor breeding ratio. Other advantages of the MSFR design are the possibility for actinide burning and extending fuel resources, on-line fuel loading and reprocessing and the use of novel passive safety systems such as the fuel salt draining system. The reference MSFR concept is a 3000 MW(th) reactor with three different circuits: the fuel circuit, the intermediate circuit and the power conversion system. The main components of the fuel circuit are the fuel salt which serves as fuel and coolant, the core cavity, the inlet and outlet pipes, the gas injection system (not shown in the figure), the salt-bubble separators, the fuel heat exchangers and the pumps. A lithium fluoride salt has been selected as the fuel matrix. The initial composition (non-irradiated) of the MSFR fuel salt is a mixture of a lithium fluoride, thorium fluoride salts and actinides fluoride (LiF-ThF{sub 4}-{sup 233}UF{sub 4} or LiF-ThF{sub 4}- {sup enr}UF{sub 4}-(Pu-MA)F{sub 3}), with the proportion of LiF fixed at about Development of accurate numerical models for the MSFR can only be accomplished by the use of a multiphysics approach which allows taking into account the coupling between relevant neutronics, thermal hydraulics and thermomechanics phenomena. As it is discussed in the next section, such a reactor model requires further progress on the knowledge of molten salt thermal hydraulics, in particular regarding the accuracy of the fuel salt Computational Fluid Dynamics (CFD) models. The Salt at Wall: Thermal Exchanges (SWATH) experiment is being designed to contribute to this particular point. SWATH is one of the experimental activities of the European H2020 SAMOFAR project and includes both experimental and numerical developments. The main objectives of SWATH are to: (i) Improve molten salt numerical models used for design and safety studies and (ii) Demonstrate the working principles of the cold plug device. The cold plug device is a key safety component of the salt draining system of the MSFR. The cold plug is intended to passively melt during accidental conditions thus allowing the flow of the nuclear fuel from the core cavity to the fuel salt draining tanks by gravity forces. The fuel salt draining tanks are designed to ensure that adequate margins are obtained regarding the fuel cooling capabilities and the reactivity control. The next sections provide an overview of the current challenges in molten salt thermal hydraulics modeling and the SWATH experiment design. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

SU-F-BRA-11: An Experimental Commissioning Test of Brachytherapy MBDCA Dosimetry, Based On a Commercial Radiochromic Gel/optical CT System

Purpose: To implement a 3D dose verification procedure of Model-Based Dose Calculation Algorithms (MBDCAs) for {sup 192}Ir HDR brachytherapy, based on a novel Ferrous Xylenol-orange gel (FXG) and optical CT read-out. Methods: The TruView gel was employed for absolute dosimetry in conjunction with cone-beam optical CT read-out with the VISTA scanner (both from Modus Medical Inc, London, ON, Canada). A multi-catheter skin flap was attached to a cylindrical PETE jar (d=9.6cm, h=16cm) filled with FXG, which served as both the dosimeter and the water equivalent phantom of bounded dimensions. X- ray CT image series of the jar with flap attached was imported to Oncentra Brachy v.4.5. A treatment plan consisting of 8 catheters and 56 dwell positions was generated, and Oncentra-ACE MBDCA as well as TG43 dose results were exported for further evaluation. The irradiation was carried out with a microSelecton v2 source. The FXG dose-response, measured via an electron irradiation of a second dosimeter from the same batch, was linear (R2>0.999) at least up to 12Gy. A MCNP6 input file was prepared from the DICOM-RT plan data using BrachyGuide to facilitate Monte Carlo (MC) simulation dosimetry in the actual experimental geometry. Agreement between experimental (reference) and calculated dose distributions was evaluated using the 3D gamma index (GI) method with criteria (5%-2mm applied locally) determined from uncertainty analysis. Results: The TG-43 GI failed, as expected, in the majority of voxels away from the flap (pass rate 59% for D>0.8Gy, corresponding to 10% of prescribed dose). ACE performed significantly better (corresponding pass rate 92%). The GI evaluation for the MC data (corresponding pass rate 97%) failed mainly at low dose points of increased uncertainty. Conclusion: FXG gel/optical CT is an efficient method for level-2 commissioning of brachytherapy MBDCAs. Target dosimetry is not affected from uncertainty introduced by TG43 assumptions in 192Ir skin brachytherapy. Research co-financed by the ESF and Greek funds through the Operational Program Education and Lifelong Learning Investing in Knowledge Society of the NSRF. Research Funding Program: Aristeia. Modus Medical Devices Inc. provided a TruView dosimeter batch and Nucletron, and Elekta company, provided access to Oncentra Brachy v4.5, for research purposes.

60 APPLIED LIFE SCIENCES↗

WE-EF-303-05: Development and Commissioning of Real-Time Imaging Function for Respiratory-Gated Spot-Scanning Proton Beam Therapy

Purpose: To realize real-time-image gated proton beam therapy (RGPT) for treating mobile tumors. Methods: The rotating gantry of spot scanning proton beam therapy has been designed to equip two x-ray fluoroscopy devices that enable real-time imaging of the internal fiducial markers during respiration. Three-dimensional position of the fiducial marker located near the tumor can be calculated from the fluoroscopic images obtained from orthogonal directions and therapeutic beam is gated only when the fiducial marker is within the predefined gating window. Image acquisition rate can be selected from discrete value ranging from 0.1 Hz to 30 Hz. In order to confirm the effectiveness of RGPT and apply it clinically, clinical commissioning was conducted. Commissioning tests were categorized to main three parts including geometric accuracy, temporal accuracy and dosimetric evaluation. Results: Developed real-time imaging function has been installed and its basic performances have been confirmed. In the evaluation of geometric accuracy, coincidence of three-dimensional treatment room coordinate system and imaging coordinate system was confirmed to be less than 1 mm. Fiducial markers (gold sphere and coil) were able to be tracked in simulated clinical condition using an anthropomorphic chest phantom. In the evaluation of temporal accuracy, latency from image acquisition to gate on/off signal was about 60 msec in typical case. In dosimetric evaluation, treatment beam characteristics including beam irradiation position and dose output were stable in gated irradiation. Homogeneity indices to the mobile target were 0.99 (static), 0.89 (w/o gating, motion is parallel to direction of scan), 0.75 (w/o gating, perpendicular), 0.98 (w/ gating, parallel) and 0.93 (w/ gating, perpendicular). Dose homogeneity to the mobile target can be maintained in RGPT. Conclusion: Real-time imaging function utilizing x-ray fluoroscopy has been developed and commissioned successfully in order to realize RGPT. Funding Support: This research was partially supported by Japan Society for the Promotion of Science (JSPS) through the FIRST Program. Conflict of Interest: Prof. Shirato has research fund from Hitachi Ltd, Mitsubishi Heavy Industries Ltd and Shimadzu Corporation.

60 APPLIED LIFE SCIENCES↗

Multileaf collimator performance monitoring and improvement using semiautomated quality control testing and statistical process control

Purpose: High-quality radiation therapy using highly conformal dose distributions and image-guided techniques requires optimum machine delivery performance. In this work, a monitoring system for multileaf collimator (MLC) performance, integrating semiautomated MLC quality control (QC) tests and statistical process control tools, was developed. The MLC performance monitoring system was used for almost a year on two commercially available MLC models. Control charts were used to establish MLC performance and assess test frequency required to achieve a given level of performance. MLC-related interlocks and servicing events were recorded during the monitoring period and were investigated as indicators of MLC performance variations. Methods: The QC test developed as part of the MLC performance monitoring system uses 2D megavoltage images (acquired using an electronic portal imaging device) of 23 fields to determine the location of the leaves with respect to the radiation isocenter. The precision of the MLC performance monitoring QC test and the MLC itself was assessed by detecting the MLC leaf positions on 127 megavoltage images of a static field. After initial calibration, the MLC performance monitoring QC test was performed 3–4 times/week over a period of 10–11 months to monitor positional accuracy of individual leaves for two different MLC models. Analysis of test results was performed using individuals control charts per leaf with control limits computed based on the measurements as well as two sets of specifications of ±0.5 and ±1 mm. Out-of-specification and out-of-control leaves were automatically flagged by the monitoring system and reviewed monthly by physicists. MLC-related interlocks reported by the linear accelerator and servicing events were recorded to help identify potential causes of nonrandom MLC leaf positioning variations. Results: The precision of the MLC performance monitoring QC test and the MLC itself was within ±0.22 mm for most MLC leaves and the majority of the apparent leaf motion was attributed to beam spot displacements between irradiations. The MLC QC test was performed 193 and 162 times over the monitoring period for the studied units and recalibration had to be repeated up to three times on one of these units. For both units, rate of MLC interlocks was moderately associated with MLC servicing events. The strongest association with the MLC performance was observed between the MLC servicing events and the total number of out-of-control leaves. The average elapsed time for which the number of out-of-specification or out-of-control leaves was within a given performance threshold was computed and used to assess adequacy of MLC test frequency. Conclusions: A MLC performance monitoring system has been developed and implemented to acquire high-quality QC data at high frequency. This is enabled by the relatively short acquisition time for the images and automatic image analysis. The monitoring system was also used to record and track the rate of MLC-related interlocks and servicing events. MLC performances for two commercially available MLC models have been assessed and the results support monthly test frequency for widely accepted ±1 mm specifications. Higher QC test frequency is however required to maintain tighter specification and in-control behavior.

07 ISOTOPE AND RADIATION SOURCES↗

Laser-Assisted Synthesis of Monolayer 2D MoSe 2 Crystals with Tunable Vacancy Concentrations: Implications for Gas and Biosensing

We report tuning the structural and electronic properties of atomically thin two-dimensional (2D) materials via defect and vacancy engineering is the key to enabling their potential use in various applications, including electronics, energy, and sensing devices. Vacancies are, for instance, becoming highly promising for the enhanced interaction of gases and biomolecules with 2D materials in energy and sensing applications. However, the deterministic generation of desirable vacancies with tunable concentrations remains a challenge in 2D materials due to the limitations in the current growth methods, such as the complex reaction chemistries and gas flow dynamics. Therefore, engineering defects and vacancies in 2D materials have been mainly limited to destructive top-down processes such as heating, ion bombardments, and laser postprocessing. Here, we introduce a single-step bottom-up synthesis approach for the growth of monolayer MoSe 2 crystals with tunable vacancy concentrations. This method utilizes the spatiotemporal properties and adjustable power densities of the lasers to control the vaporization dynamics of the stoichiometric MoSe 2 powders. Such a mechanism in the vaporization allows us to grow tunable stoichiometry monolayer MoSe 2–x crystals on the substrates. The localized and time-controlled (250 ms to 2 s) vaporization of the MoSe 2 powder by a CO 2 laser enables the formation of monolayer crystals with controlled vacancy concentrations ranging from ~1 to 20%. The effects of laser power, laser irradiation time, and background pressure on the tuning range and subsequent properties of the crystals are investigated and quantified using Raman and photoluminescence spectroscopy, scanning transmission electron microscopy (STEM), and time-correlated single-photon counting (TCSPC). This bottom-up synthesis is a promising approach that allows the deterministic vacancy tuning for future electronics and, in particular, gas and biosensing applications without the need for further postprocessing and potential structural disruption of the crystals.

2D materials↗

In-situ Characterizations of Microstructural Degradation of Perovskite Solar Cells

Rapid progress has been achieved in perovskite solar cells (PSCs), and their efficiencies have improved from 3.8 % to 24.2 % in less than a decade. With low-cost processing, PSCs have shown exciting photovoltaic (PV) properties, such as effective optical absorption, a long carrier lifetime, and unique defect tolerance. While recent studies demonstrated improved stability up to 100 days, PSC technology is still challenged to meet the stringent industry requirements for commercialization. Despite considerable efforts, the underlying physical mechanisms for the inferior stability of PSCs are not well understood. One reason for this divergence is that many established measurement techniques (e.g., quantum efficiency, photoluminescence) probe the properties on length scales far greater than that of electronic and/or structural inhomogeneity (i.e., < 1 μm near grain boundaries) and therefore characterize convoluted and/or averaged properties. Ion/electron beam-based techniques have been extensively used to access the microstructures of PSCs, enabling atomic/nanoscale structural, chemical, optical, and electrical characterizations. For example, focused ion beam (FIB) milling produces an atomically smooth surface that minimizes the artifacts attributed to the surface roughness. FIB techniques can also create a well-defined cross-section of PSCs without mechanical damage in a physical cleaving sample preparation. While powerful, there are some concerns about possible beam damage of inorganic-organic perovskites via chemical-bond breakage and local heating. This project aims to comprehensively understand how the microstructural/interfacial properties of PSCs (e.g., Methylammonium Lead Iodide [MAPbI 3 ]) are modified under the irradiating ion beams. Specifically, we investigate the sub-surface properties of PSCs before and after Ar-ion beam injections. Kelvin probe force microscopy (KPFM) measures the contact potential differences (CPDs). Photoluminescence (PL) microscopy in conjunction with Finite-Difference Time-Domain (FDTD) simulations infers the formation of a “dead layer” (< 15 nm) on the subsurface of MAPbI 3 during Ar+ milling processes while preserving the initial bulk properties. The x-ray photoemission spectroscopy (XPS) confirms this modified surface is a lead-rich and iodine-deficient surface. We initiate customizing in-situ measurement setup while measuring the local optical and electrical properties of PSC under thermal (cooling, heating) and light stressors. Our results provide in-depth knowledge of the ion-beam impact on metal-halide perovskites and how this modified sub-surface impacts their properties under accelerated stressors of light and heat. Intensive Monte Carlo simulations of an electron beam interacting with PSCs provide the beam energy distribution in PSCs, proposing possible measurement conditions of using e-beam with minimizing beam damage. Our in-situ measurement platform can accommodate the diverse architecture of PSC devices for studying deterioration mechanisms under mixed environmental stressors.

14 SOLAR ENERGY↗

RIA Testing in TREAT

The Transient Reactor Test facility (TREAT) was constructed in the late 1950’s. The reactors flexible design and multi-mission nature provided thousands of transient irradiations for numerous reactor fuels and transient types before being placed in standby in 1994. The reactor resumed operations in 2017 to reclaim its crucial role in nuclear-heated safety research. A principal goal of restarting the reactor was to perform transient testing of Accident Tolerant Fuels (ATF), supporting their safe adoption by the commercial Light Water Reactor (LWR) fleet. In support of the Accident Tolerant Fuels mission, multiple capsules have been designed and are currently being designed to test fuel specimens under varying conditions. The Minimal Activation Retrievable Capsule Holder (MARCH) system was designed to support high throughput testing by using a modular approach where an outer containment structure will act as the primary safety containment. The MARCH system is designed to house various modules for testing different fuel systems in different environments. The near-term tests for the ATF concepts will use the Static Environment Rodlet Transient Test Apparatus (SERTTA), aka MARCH-SERTTA. MARCH-SERTTA is capable of testing a single ATF rodlet 10 cm in length in a static pool of water with initial conditions up to 200°C and 500 psi. The purpose of the MARCH-SERTTA device is to perform integral tests evaluating the Pellet Clad Mechanical Interaction (PCMI) performance of LWR fuel concepts in design basis Reactivity Initiated Accidents (RIA). This will be accomplished by testing a variety of ATF fuel concepts under varying initial thermal-hydraulic conditions and varying prompt energy pulses. The flexibility of TREAT and the MARCH-SERTTA capsule enables testing of a unique, non-fueled, rod specimen under similar conditions as the fueled specimens to perform separate-effect tests. This non-fueled rod will be used to study the thermal-hydraulic behavior (specifically determine the critical heat flux) during these fast prompt transients.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Ultrafast optical control of surface and bulk magnetism in magnetic topological insulator/antiferromagnet heterostructure

Abstract Optical control of the magnetic properties in topological insulator systems is an important step in applying these materials in ultrafast optoelectronic and spintronic schemes. In this work, we report the experimental observation of photo-induced magnetization dynamics in the magnetically doped topological insulator (MTI)/antiferromagnet (AFM) heterostructure composed of Cr-(Bi,Sb) 2 Te 3 /CrSb. Through proximity coupling to the AFM layer, the MTI displays a dramatically enhanced magnetism, with robust perpendicular magnetic anisotropy. When subjected to intense laser irradiation, both surface and bulk magnetism of the MTI are weakened by laser-induced heating of the lattice, however, at the surface, the deleterious heat effect is compensated by the strengthening of Dirac-hole-mediated exchange coupling as demonstrated by an unconventional pump-fluence-dependent exchange-bias effect. Through theoretical analyses, the sizes of exchange coupling energies are estimated in the MTI/AFM bilayer structure. The fundamentally different mechanisms supporting the surface and bulk magnetic order in MTIs allow a novel and distinctive photo-induced transient magnetic state with antiparallel spin configuration, which broadens the understanding of the magnetization dynamics of MTIs under ultrashort and intense optical excitation.

42 ENGINEERING↗

K-shell spectroscopy of silicon ions as diagnostic for high electric fields

We developed a detection scheme, capable of measuring X-ray line shape of tracer ions in {mu}m thick layers at the rear side of a target foil irradiated by ultra intense laser pulses. We performed simulations of the effect of strong electric fields on the K-shell emission of silicon and developed a spectrometer dedicated to record this emission. The combination of a cylindrically bent crystal in von Hamos geometry and a CCD camera with its single photon counting capability allows for a high dynamic range of the instrument and background free spectra. This approach will be used in future experiments to study electric fields of the order of TV/m at high density plasmas close to solid density.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ZrO{sub 2} quantum dots/graphene phototransistors for deep UV detection

Graphical abstract: Electron-hole pairs are generated in the ZrO2 quantum dot film under UV light irradiation, and then holes transfer to graphene layer due to the lower energy levels for holes in graphene, leaving electrons trapped in the ZrO2 QDs, which acted as an additional light tunable gate. The graphene and ZrO2 quantum dots act as the conducting channel and the light absorption layer respectively. - Highlights: • High photo-responsivity and low-cost photo-transistors for deep-UV detection based on graphene decorated with ZrO2 . • Graphene has been used as carrier transport channel and ZrO2 QDs provide strong advantage of deep-UV absorption. • Electron-hole pairs get separated at the interface between graphene and ZrO2 QDs, which leads to the transfer of holes from QDs towards graphene, and the traps of electrons in the ZrO2 QDs that acted as an additional light tunable gate.Electron-hole pairs get separated at the interface between graphene and ZrO2 QDs, which leads to the transfer of holes from QDs towards graphene, and the traps of electrons in the ZrO2 QDs that acted as an additional light tunable gate. - Abstract: ZrO{sub 2} is a promising material for deep-UV detection application, yet the low carrier density and high crystal lattice defects hinder the device performance. Graphene is an attractive material for photoactive and charge transport layers in photodetectors, but the photoresponsivity have been limited by the weak light absorption, no wavelength selectivity. Here, we demonstrate heterostructure phototransistors consist of graphene as the conducting channel, which is covered by a film of ZrO{sub 2} quantum dots as the light absorption layer. Light absorption in the quantum dots layer creates electron-hole pairs. Under the built-in electric field, the electrons are trapped in ZrO{sub 2} acting as an additional light tunable gate, whereas the holes are transferred towards the graphene. The ZnO{sub 2}/Graphene heterostructure, with a high photoresponsivity of 22 A W{sup −1} and wavelength selectivity to deep UV wavelength range (220–250 nm) at low operating voltage, is promising to be integrated into solution processed and low-cost optoelectrical devices.

36 MATERIALS SCIENCE↗

Evaluation of a 3D Diode Array Dosimeter for Helical Tomotherapy Delivery QA

The Delta4 biplanar diode array dosimeter was validated for helical tomotherapy delivery QA. The basic detector characteristics were found to be satisfactory in terms of short-term reproducibility (0.1%), linearity (<0.1%), dose rate dependence (0.4%), and absolute calibration accuracy (0.4% in the center of the phantom compared with the independently calibrated diode). Relative calibration of the arrays was verified by comparison with film and by rotating the detector 180{sup o}. The dosimeter response to rotational irradiation changed by no more than 0.2% when one of the detector boards was replaced by the homogeneous phantom material. The daily output correction factor can be derived from a Delta4 measurement in a uniform cylindrical field. The {gamma}(3%, 3 mm) passing rate (absolute dose) was above 90% for all 9 evaluated clinical plans, and above 96% for all but one. The mean passing rate was 97 {+-} 2.7%. The plans varied in modulation factor, pitch, and calculation grid size. For best results, the phantom needs to be aligned carefully, preferably by megavoltage computed tomography imaging.

07 ISOTOPE AND RADIATION SOURCES↗

Effect of laser parameters and assist gas on spectral response of silicon fibrous nanostructure

This article report, for the first time, the influence of laser parameters on the spectral response of weblike silicon fibrous nanostructures. These nanostructures are formed by femtosecond laser irradiation at megahertz pulse frequency under atmosphere and nitrogen ambient. The observed decreasing in reflectance is correlated with the density of fibrous nanostructures and the size of the agglomerated nanoparticles. Compared to bulk silicon, Raman spectra of fibrous nanostructures shows a downward shift and asymmetric broadening at the first order phonon peak. The shift and broadening are attributed to phonon confinement of fibrous nanostructure. Polarization and nitrogen gas modify the morphology of generated nanomaterials but does not have effect on light absorptance. Pulsewidth and pulse frequency do not have significant effect on light absorptance.

36 MATERIALS SCIENCE↗

Superior photodynamic effect of single-walled carbon nanotubes in aprotic media: a kinetic study

It has been confirmed that single-walled carbon nanotubes (SWCNTs) could generate reactive oxygen species in aprotic media by utilizing photon energy. However, the impact of photon irradiation on SWCNTs and the kinetics of the generation process in aprotic media are still unclear, which significantly limits the yield performance. In this work, the kinetics for photodynamic effects has been investigated by performing characterizations on ultraviolet-treated SWCNTs using Raman spectroscopy, conductive atomic force microscope (in-situ), kelvin probe force microscope, and X-ray photoelectron spectroscopy. It is found that ultraviolet-treated SWCNTs are observed to have more defects, lower conductivity, and less surface charge after energy conversion. Starting from the fundamental intrinsic properties of SWCNTs, the kinetics and formation of these changes are thoroughly discussed. It turns out that the dispersion, chirality, and structural integrity of SWCNTs are important for achieving high-performance photodynamic effects, which are validated using several different SWCNTs as well as other carbon nanomaterials. A type of (6,5) s-SWCNTs exhibited the highest energy efficiency among a variety of other carbon nanomaterials. The yield rate is 2.15 mM/h, and the energy consumption is determined to be 2.79 W∙h/mM. This work is expected to help dramatically boost the energy efficiency of the photodynamic effect in aprotic media and pave the way for designing high-performance carbon nanomaterial-based photoinduced devices.

36 MATERIALS SCIENCE↗

Neutronics Design of a Thorium-Fueled Fission Blanket for LIFE (Laser Inertial Fusion-based Energy)

The Laser Inertial Fusion-based Energy (LIFE) project at LLNL includes development of hybrid fusion-fission systems for energy generation. These hybrid LIFE engines use high-energy neutrons from laser-based inertial confinement fusion to drive a subcritical blanket of fission fuel that surrounds the fusion chamber. The fission blanket contains TRISO fuel particles packed into pebbles in a flowing bed geometry cooled by a molten salt (flibe). LIFE engines using a thorium fuel cycle provide potential improvements in overall fuel cycle performance and resource utilization compared to using depleted uranium (DU) and may minimize waste repository and proliferation concerns. A preliminary engine design with an initial loading of 40 metric tons of thorium can maintain a power level of 2000 MW{sub th} for about 55 years, at which point the fuel reaches an average burnup level of about 75% FIMA. Acceptable performance was achieved without using any zero-flux environment 'cooling periods' to allow {sup 233}Pa to decay to {sup 233}U; thorium undergoes constant irradiation in this LIFE engine design to minimize proliferation risks and fuel inventory. Vast reductions in end-of-life (EOL) transuranic (TRU) inventories compared to those produced by a similar uranium system suggest reduced proliferation risks. Decay heat generation in discharge fuel appears lower for a thorium LIFE engine than a DU engine but differences in radioactive ingestion hazard are less conclusive. Future efforts on development of thorium-fueled LIFE fission blankets engine development will include design optimization, fuel performance analysis work, and further waste disposal and nonproliferation analyses.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A non-fueled nuclear-heated rod for in-pile transient boiling studies

Separate-effects boiling experiments have recently been conducted in the Transient Reactor Test Facility at Idaho National Laboratory to investigate transient heating and irradiation effects on cladding-to-coolant heat transfer. Specifically, transient critical heat flux (CHF) remains an important area of research, and better understanding of this phenomenon has potential for improving predictive models related to operational and safety limits. Consequently, this knowledge is expected to improve efficiency of light-water reactor operations. A novel borated nuclear-heated rodlet (BNHR) was designed to enable observation of transient cladding-to-coolant heat transfer phenomena. The final BNHR design takes a surrogate approach, wherein nuclear heating is induced by 10 B(n, α) reactions rather than derived from fissions in a fueled specimen. The structure of the BNHR consists of a hollowed out borated (B nat ~ 2.05 wt %) stainless steel tube with an hourglass-shaped outer surface, capped at both ends with non-borated stainless steel. This geometry allows for inner-rodlet instrumentation and generation of the highest nuclear heating rates near the center of the rodlet to ensure onset of boiling near instrumentation for real-time observation. A novel approach to measuring the nuclear energy deposition rate in the BNHR separate and apart from the influence of the coolant, termed the n-a thermometer, is also detailed in this paper. This device has demonstrated excellent repeatability, and measurements indicate predictive modeling results for energy deposition in the BNHR rod agree within a 10% margin of the experiment measurements. In conclusion, these results give confidence that the BNHR design has successfully met experiment objectives.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Spectroscopic Chemical Analysis Methods and Apparatus

This invention relates to non-contact spectroscopic methods and apparatus for performing chemical analysis and the ideal wavelengths and sources needed for this analysis. It employs deep ultraviolet (200- to 300-nm spectral range) electron-beam-pumped wide bandgap semiconductor lasers, incoherent wide bandgap semiconductor lightemitting devices, and hollow cathode metal ion lasers. Three achieved goals for this innovation are to reduce the size (under 20 L), reduce the weight [under 100 lb (.45 kg)], and reduce the power consumption (under 100 W). This method can be used in microscope or macroscope to provide measurement of Raman and/or native fluorescence emission spectra either by point-by-point measurement, or by global imaging of emissions within specific ultraviolet spectral bands. In other embodiments, the method can be used in analytical instruments such as capillary electrophoresis, capillary electro-chromatography, high-performance liquid chromatography, flow cytometry, and related instruments for detection and identification of unknown analytes using a combination of native fluorescence and/or Raman spectroscopic methods. This design provides an electron-beampumped semiconductor radiation-producing method, or source, that can emit at a wavelength (or wavelengths) below 300 nm, e.g. in the deep ultraviolet between about 200 and 300 nm, and more preferably less than 260 nm. In some variations, the method is to produce incoherent radiation, while in other implementations it produces laser radiation. In some variations, this object is achieved by using an AlGaN emission medium, while in other implementations a diamond emission medium may be used. This instrument irradiates a sample with deep UV radiation, and then uses an improved filter for separating wavelengths to be detected. This provides a multi-stage analysis of the sample. To avoid the difficulties related to producing deep UV semiconductor sources, a pumping approach has been developed that uses ballistic electron beam injection directly into the active region of a wide bandgap semiconductor material.

Hug, William F.↗