Search NASA⌕ Search

SEARCH · Search NASA

Results for “Integrated circuits.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

Evaluation of a CdTe semiconductor based compact gamma camera for sentinel lymph node imaging

Purpose: The authors assembled a prototype compact gamma-ray imaging probe (MediPROBE) for sentinel lymph node (SLN) localization. This probe is based on a semiconductor pixel detector. Its basic performance was assessed in the laboratory and clinically in comparison with a conventional gamma camera. Methods: The room-temperature CdTe pixel detector (1 mm thick) has 256x256 square pixels arranged with a 55 {mu}m pitch (sensitive area 14.08x14.08 mm{sup 2}), coupled pixel-by-pixel via bump-bonding to the Medipix2 photon-counting readout CMOS integrated circuit. The imaging probe is equipped with a set of three interchangeable knife-edge pinhole collimators (0.94, 1.2, or 2.1 mm effective diameter at 140 keV) and its focal distance can be regulated in order to set a given field of view (FOV). A typical FOV of 70 mm at 50 mm skin-to-collimator distance corresponds to a minification factor 1:5. The detector is operated at a single low-energy threshold of about 20 keV. Results: For {sup 99m}Tc, at 50 mm distance, a background-subtracted sensitivity of 6.5x10{sup -3} cps/kBq and a system spatial resolution of 5.5 mm FWHM were obtained for the 0.94 mm pinhole; corresponding values for the 2.1 mm pinhole were 3.3x10{sup -2} cps/kBq and 12.6 mm. The dark count rate was 0.71 cps. Clinical images in three patients with melanoma indicate detection of the SLNs with acquisition times between 60 and 410 s with an injected activity of 26 MBq {sup 99m}Tc and prior localization with standard gamma camera lymphoscintigraphy. Conclusions: The laboratory performance of this imaging probe is limited by the pinhole collimator performance and the necessity of working in minification due to the limited detector size. However, in clinical operative conditions, the CdTe imaging probe was effective in detecting SLNs with adequate resolution and an acceptable sensitivity. Sensitivity is expected to improve with the future availability of a larger CdTe detector permitting operation at shorter distances from the patient skin.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-570: Management of Radiation Oncology Patients with Cochlear Implant and Other Bionic Devices in the Brain and Head and Neck Regions

Purpose: To investigate the current status of clinical usage of cochlear implant (CI) and other bionic devices (BD) in the brain and head and neck regions (BH and N) and their management in patients during radiotherapy to ensure patient health and safety as well as optimum radiation delivery. Methods: Literature review was performed with both CIs and radiotherapy and their variants as keywords in PubMed, INSPEC and other sources. The focus was on CIs during radiotherapy, but it also included other BDs in BHȦN, such as auditory brainstem implant, bionic retinal implant, and hearing aids, among others. Results: Interactions between CIs and radiation may cause CIs malfunction. The presence of CIs may also cause suboptimum dose distribution if a treatment plan was not well designed. A few studies were performed for the hearing functions of CIs under irradiations of 4 MV and 6 MV x-rays. However, x-rays with higher energies (10 to 18 MV) broadly used in radiotherapy have not been explored. These higher energetic beams are more damaging to electronics due to strong penetrating power and also due to neutrons generated in the treatment process. Modern CIs are designed with more and more complicated integrated circuits, which may be more susceptible to radiation damage and malfunction. Therefore, careful management is important for safety and treatment outcomes. Conclusion: Although AAPM TG-34, TG-63, and TG-203 (update of TG-34, not published yet) reports may be referenced for management of CIs and other BDs in the brain and H and N regions, a site- and device-specified guideline should be developed for CIs and other BDs. Additional evaluation of CI functions under clinically relevant set-ups should also be performed to provide clinicians with better knowledge in clinical decision making.

60 APPLIED LIFE SCIENCES↗

SU-D-213-01: Transparent Photon Detector For The Online Monitoring Of IMRT Beams

Purpose: An innovative Transparent Detector for Radiotherapy (TraDeRa) has been developed. The detector aims at real-time monitoring of modulated beam ahead of the patient during delivery sessions, with a field cover up to 40×40 cm {sup 2}. Methods: TraDeRa consists in a pixelated matrix of ionization chambers with a patented electrodes design. An in-house designed specific integrated circuit allows to extract the signal and provides a real-time map of beam intensity and shape, at the linac pulse-scale. The measurements under irradiation are made with a 6 MV clinical X-Ray beam. Dose calculations are performed with the Monte Carlo code PENELOPE, modeling the full accelerator head and the TraDeRa detector. Results: A 2 % attenuation of the beam was measured in the presence of TraDeRa and the PENELOPE dosimetric study showed no significant modification of the photon beam properties. TraDeRa detects error leaf position as small as 1 mm compared to a reference field, for both static and modulated fields. In addition, measurements are accurate over a large dynamic range from low intensity signals, as inter-leaves leaks, to very high intensities as obtained on the medical line of the European Synchrotron Radiation Facility. The detector is fully operational for conventional and high dose rate beams as FFF modes (up to 2400 MU/min). Conclusion: The current version of TraDeRa shows promising results for IMRT quality assurance (QA), allowing pulse-scale monitoring of the beam and high sensitivity for errors detection. The attenuation is small enough not to hinder the irradiation while keeping the beam upstream of the patient under constant control. A final prototype under development will include 1600 independent electrodes, half of them with a high resolution centered on the beam axis. This compact detector provides an independent set of measurements for a better QA. Funding support : This work was supported by the LABEX PRIMES (ANR-11-LABX-0063) of Universite de Lyon, within the program “Investissements d’Avenir” (ANR-11-IDEX-0007) operated by the French National Research Agency (ANR) and within the project “INSPIRA” operated by the OSEO institution.

60 APPLIED LIFE SCIENCES↗

Dislocation-driven growth of two-dimensional lateral quantum-well superlattices

Here, the advent of two-dimensional (2D) materials has led to extensive studies of heterostructures for novel applications. 2D lateral multiheterojunctions and superlattices have been recently demonstrated, but the available growth methods can only produce features with widths in the micrometer or, at best, 100-nm scale and usually result in rough and defective interfaces with extensive chemical intermixing. Widths smaller than 5 nm, which are needed for quantum confinement effects and quantum-well applications, have not been achieved. We demonstrate the growth of sub–2-nm quantum-well arrays in semiconductor monolayers, driven by the climb of misfit dislocations in a lattice-mismatched sulfide/selenide heterointerface. Density functional theory calculations provide an atom-by-atom description of the growth mechanism. The calculated energy bands reveal type II alignment suitable for quantum wells, suggesting that the structure could, in principle, be turned into a “conduit” of conductive nanoribbons for interconnects in future 2D integrated circuits via n-type modulation doping. This misfit dislocation–driven growth can be applied to different combinations of 2D monolayers with lattice mismatch, paving the way to a wide range of 2D quantum-well superlattices with controllable band alignment and nanoscale width.

36 MATERIALS SCIENCE↗

High-performance silicon photonic single-sideband modulators for cold-atom interferometry

The laser system is the most complex component of a light-pulse atom interferometer (LPAI), controlling frequencies and intensities of multiple laser beams to configure quantum gravity and inertial sensors. Its main functions include cold-atom generation, state preparation, state-selective detection, and generating a coherent two-photon process for the light-pulse sequence. To achieve substantial miniaturization and ruggedization, we integrate key laser system functions onto a photonic integrated circuit. Our study focuses on a high-performance silicon photonic suppressed-carrier single-sideband (SC-SSB) modulator at 1560 nanometers, capable of dynamic frequency shifting within the LPAI. By independently controlling radio frequency (RF) channels, we achieve 30-decibel carrier suppression and unprecedented 47.8-decibel sideband suppression at peak conversion efficiency of –6.846 decibels (20.7%). We investigate imbalances in both amplitudes and phases between the RF signals. Using this modulator, we demonstrate cold-atom generation, state-selective detection, and atom interferometer fringes to estimate gravitational acceleration, g ≈ 9.77 ± 0.01 meters per second squared, in a rubidium ( 87 Rb) atom system.

47 OTHER INSTRUMENTATION↗

Ferroelectric materials toward next-generation electromechanical technologies

Ferroelectric materials have been widely used in various electromechanical devices, from ultrasonic transducers and actuators to mechanical energy harvesters. The key performance metrics of these devices, such as sensitivity, efficiency, and bandwidth of ultrasonic transducers, are largely determined by the piezoelectric properties. This Review highlights recent research progress in improving the piezoelectricity of ferroelectric materials and offers potential strategies for further enhancement to meet the ever-increasing demands for high-performance piezoelectric devices and systems. Here, it provides insights into the future development of ferroelectrics to address the increasing demands of emerging applications, including photoacoustic imaging and piezoelectric fans and motors in integrated circuit–enabled electronic devices. Additionally, it emphasizes the need to consider environmental impacts across the entire life cycle of ferroelectrics, from sourcing and manufacturing to usage and disposal.

36 MATERIALS SCIENCE↗

First Results in Studying the Readout Electronics of the Silicon Tracking System for Upgrading the CLAS12 Experiment

Investigations of the readout electronics for the tracking system of the CLAS12 experiment have been performed for the last 2 years. The setup and physical problems of the CLAS12 experiment are described. The silicon detectors designed by the authors for the tracking system of the experiment are considered in brief. The electronic system contains the silicon microstrip detector and FSSR2 integrated circuit, which reads signals from the detector. The FSSR2 chip is described and the principles of the chip architecture intended for processing a time-variable data flow and experimental characteristics obtained on trials of the chip are set forth in brief. Results of simulating the chip throughput under loads expected for the physical experiment and experimental characteristics obtained on trials of this chip are described.

42 ENGINEERING↗

Effect of defects on the kinetics of the phase transformation in a one-dimensional system: Modified Kolmogorov-Mehl-Johnson theory

The statistical Kolmogorov-Mehl-Johnson theory of solidification is generalized with allowance for the effect of obstacles creating delays for the propagation of new-phase boundaries, as applied to one-dimensional systems. An equation is derived to describe the process kinetics and is used to calculate the time dependence of the fraction of a transformed substance. The modification of the kinetics caused by changes in the obstacle density and the obstacle-induced delay time is studied. The theory can be applied to the extended contacts in large-scale integration circuits, biological macromolecules, and many other systems.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Tungsten fragmentation in nuclear reactions induced by high-energy cosmic-ray protons

Tungsten fragmentation arising in nuclear reactions induced by cosmic-ray protons in space-vehicle electronics is considered. In modern technologies of integrated circuits featuring a three-dimensional layered architecture, tungsten is frequently used as a material for interlayer conducting connections. Within the preequilibrium model, tungsten-fragmentation features, including the cross sections for the elastic and inelastic scattering of protons of energy between 30 and 240 MeV; the yields of isotopes and isobars; their energy, charge, and mass distributions; and recoil energy spectra, are calculated on the basis of the TALYS and EMPIRE-II-19 codes. It is shown that tungsten fragmentation affects substantially forecasts of failures of space-vehicle electronics.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Development of methods for calculating basic features of the nuclear contribution to single event upsets under the effect of protons of moderately high energy

As a continuation and a development of previous studies of our group that were devoted to the investigation of nuclear reactions induced by protons of moderately high energy (between 10 and 400 MeV) in silicon, aluminum, and tungsten atoms, the results obtained by exploring nuclear reactions on atoms of copper, which is among the most important components in materials for contact pads and pathways in modern and future ultralarge-scale integration circuits, especially in three-dimensional topology, are reported in the present article. The nuclear reactions in question lead to the formation of the mass and charge spectra of recoil nuclei ranging fromheavy target nuclei down to helium and hydrogen. The kineticenergy spectra of reaction products are calculated. The results of the calculations based on the procedure developed by our group are compared with the results of calculations and experiments performed by other authors.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Properties of ZnSe/Al{sub 2}O{sub 3} Nanostructures Obtained by RF Magnetron Sputtering

Experimental data for the synthesis of ZnSe/Al{sub 2}O{sub 3} nanostructures utilizing a technology widely used in integrated circuit (IC) production are reported. It has been shown that the refractive index and size of the coherent scattering domains grow, whereas the energy bandgap decreases, with an increase in ZnSe width. It has been supposed that samples with a ZnSe width of 9 Å contain a ZnSeO{sub 3} compound and/or ZnSe ⋅ Al{sub 2}O{sub 3} complex compound. Multilayer heterostructures with a ZnSe width more than 9 Å contain cubic ZnSe nanocrystallites.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

The in-silico lab-on-a-chip: petascale and high-throughput simulations of microfluidics at cell resolution

We present simulations of blood and cancer cell separation in complex microfluidic channels with subcellular resolution, demonstrating unprecedented time to solution, performing at 65.5% of the available 39.4 PetaInstructions/s in the 18, 688 nodes of the Titan supercomputer. These simulations outperform by one to three orders of magnitude the current state of the art in terms of numbers of simulated cells and computational elements. The computational setup emulates the conditions and the geometric complexity of microfluidic experiments and our results reproduce the experimental findings. These simulations provide sub-micron resolution while accessing time scales relevant to engineering designs. We demonstrate an improvement of up to 45X over competing state-of-the-art solvers, thus establishing the frontiers of simulations by particle based methods. Our simulations redefine the role of computational science for the development of microfluidics –- a technology that is becoming as important to medicine as integrated circuits have been to computers.

Computer Science↗

SpacelyProject/spacely-docs

Spacely is an open-source framework for the post-silicon validation of analog, digital, and mixed-signal ASICs (Application-Specific Integrated Circuits) which maximizes the reuse of hardware and software, reducing the time taken to achieve meaningful test results. Spacely specifically addresses the needs of small, flexible ASIC design teams commonly found in academia or research institutions. Spacely was originally developed at Fermi National Accelerator Laboratory.

Quinn, Adam [Fermi National Accelerator Laboratory↗

Toward lower-diameter large-scale HPC and data center networks with co-packaged optics

We investigate the advantages of using co-packaged optics for building low-diameter, large-scale high-performance computing (HPC) and data center networks. The increased escape bandwidth offered by co-packaged optics can enable high-radix switch implementations of more than 150 switch ports, which can be combined with data rates of up to 400 Gb/s per port. From the network architecture perspective, the key benefits of using co-packaged optics in future fat-tree networks include (a) the ability to implement large-scale topologies of > <#comment/> 11 , 000 end points by eliminating the need for a third switching layer and (b) the ability to provide up to 4 × <#comment/> higher bisection bandwidth compared to existing solutions, reducing at the same time the number of required switch application-specific integrated circuits by > <#comment/> 80 % <#comment/> . From the network operation perspective, both reduced energy consumption and lower packet delays can be achieved since fewer hops are required; i.e., packets need to traverse fewer serializer/deserializer lanes and fewer switch buffers, which reduces the probability of contending with other packets and improves the tolerance of network congestion. The performance of the proposed architecture is evaluated via discrete-event simulations for a wide range of representative HPC synthetic-traffic cases that include both hotspot and non-hotspot scenarios. The simulation results suggest that co-packaged optics form a promising solution to keep up with bandwidth scaling in future networks, while the reduced number of switching layers can lead to significant mean packet delay improvements that start from 30% and reach up to 74% for high-load conditions.

Maniotis, Pavlos (ORCID:0000000244905253)↗

INTREPID program: technology and architecture for next-generation, energy-efficient, hyper-scale data centers [Invited]

The INTREPID program is developing power-efficient coherent optics for package-level integration with future switch integrated circuits as a path to realizing higher-radix switches for flatter networks. The link architecture is underpinned by coherent quadrature phase-shift keying (QPSK) polarization-multiplex transceivers at 200 Gb/s per λ <#comment/> , further enhanced with wavelength division multiplexing (WDM) to enable energy-efficient 800 or 1600 Gb/s inter-switch fiber connections. The technology is compatible with conventional three-level data center designs as well as a two-level data center design introduced here, which includes an added layer of passive, arrayed waveguide grating routers (AWGRs) or WDM circuit switches to further improve the cost, energy efficiency, and latency of the network.

Saleh, Adel A. M. (ORCID:0000000182451136)↗

Si⁺-implanted Si-wire waveguide photodetectors for the mid-infrared

CMOS-compatible Si⁺-implanted Si-waveguide p-i-n photodetectors operating at room temperature and at mid-infrared wavelengths from 2.2 to 2.3 µm are demonstrated. Responsivities of 9.9 ± 2.0 mA/W are measured at a 5 V reverse bias with an estimated internal quantum efficiency of 2.7 – 4.5%. The dark current is found to vary from a few microamps down to less than a nanoamp after a post-implantation annealing of 350°C. The measured photocurrent dependence on input power shows a linear correspondence over more than three decades, and the frequency response of a 250 µm-length p-i-n device is measured to be ~1.7 GHz for a wavelength of λ = 2.2 µm, thus potentially opening up new communication bands for photonic integrated circuits.

42 ENGINEERING↗

High-Q suspended optical resonators in 3C silicon carbide obtained by thermal annealing

We fabricate suspended single-mode optical waveguides and ring resonators in 3C silicon carbide (SiC) that operate at telecommunication wavelength, and leverage post-fabrication thermal annealing to minimize optical propagation losses. Annealed optical resonators yield quality factors of over 41,000, which corresponds to a propagation loss of 7 dB/cm, and is a significant improvement over the 24 dB/cm in the case of the non-annealed chip. This improvement is attributed to the enhancement of SiC crystallinity and a significant reduction of waveguide surface roughness, from 2.4 nm to below 1.7 nm. The latter is attributed to surface layer oxide growth during the annealing step. We confirm that the thermo-optic coefficient, an important parameter governing high-power and temperature-dependent performance of SiC, does not vary with annealing and is comparable to that of bulk SiC. Our annealing-based approach, which is especially suitable for suspended structures, offers a straightforward way to realize high-performance 3C-SiC integrated circuits.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗