Search NASA⌕ Search

SEARCH · Search NASA

Results for “LEAVES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

Lab-scaled performance evaluation of novel water-lean solvents for post combustion CO 2 capture

Here, this work focuses on demonstrating the energetic performance and operational reliability in a continuous system of RTI's water-lean solvents for post-combustion CO 2 capture applications. RTI's Non-Aqueous Solvent, NAS-1A was subjected to 100 h of continuous, CO 2 capture and regeneration operation using a Lab-scale Gas Absorption System (LsGAS) while the CO 2 capture efficiency, mass balance, and total energy inputs were monitored. Throughout the test period, NAS-1A demonstrated stable operation with 90% CO 2 capture while requiring about 15% lower total energy input for solvent regeneration compared to 30 wt% monoethanolamine (MEA) solution. The use of a slipstream of CO 2 -rich solvent from the absorber sump reduced the regenerated CO 2 temperature before the gas was further cooled by the overhead condenser at the top of the desorber. The rich-split setup combined with a wash section may be an effective approach to remove water and solvent vapor from the regenerated CO 2 as well as to recover heat at the top of the desorber. NAS-1B was later developed and included a modifier component that lowers the heat of CO 2 absorption and reduces the vapor pressure of the amine component. The total energy inputs for 90% CO 2 capture with NAS-1B was found to be 25% less than that of the MEA. A gas chromatograph was used to monitor the amine concentration in the gas leaving the absorber wash section. It was found that under similar operating conditions, the presence of the modifier in NAS-1B reduces the amine in the absorber off-gas from 143 ppm in NAS-1A to 20 ppm.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Numerical analysis of coalescence-induced bubble departure for enhanced boiling heat transfer

Boiling heat transfer plays a crucial role in a wide range of applications, such as power generation, refrigeration, electronics cooling, and pharmaceutics. Among the various factors that influence boiling heat transfer, the dynamics of vapor bubble nucleation, growth, and departure from the heated surface stand out as particularly important. An emerging phenomenon that can promote the departure of bubbles smaller than the Fritz diameter is coalescence-induced departure. If the dynamics of this process are fully understood, then surfaces can be engineered to promote faster bubble departure and substantially increase the performance of boiling heat transfer. Further, this work expands on published results by presenting a detailed numerical analysis of bubble coalescence and departure for a range of initial bubble diameters and size ratios between coalescing bubbles. Analysis of the results is focused on explaining how the release of surface energy and bubble surface dynamics lead to bubble departure, as well as fundamentally distinguishing capillary–inertial jumping and buoyant–inertial departure mechanisms across different bubble sizes and size ratios. The results show that both the initial sizes of the coalescing bubbles and the ratio between their sizes can determine whether the merged bubble will leave the surface through capillary–inertial jumping or buoyant departure. Below a certain bubble size, the release of surface energy by the merger is not sufficient to propel the merged bubble from the surface.

42 ENGINEERING↗

The influence of LiH and TiH 2 on hydrogen storage in MgB 2 I: Promotion of bulk hydrogenation at reduced temperature

Mg(BH 4 ) 2 is an attractive hydrogen storage material, owing to its high gravimetric capacity of 14.9 wt %. However, the dehydrogenated material MgB 2 is very difficult to rehydrogenate, requiring excessive pressures and temperatures. Here we report the influence of LiH and TiH 2 on hydrogen storage reactions involving Bulk MgB 2 using XRD, XAS, FTIR and NMR. In ball-milled mixtures of LiH/MgB 2 , the LiH loses crystallinity but remains undissociated, forming a weakly bound complex with MgB 2 . The weak interactions produce minor variations in the local electronic structure at B and Mg, but do not markedly affect the underlying MgB 2 hexagonal crystal structure. No evidence is found for a mixed-metal boride Mg 1-x Li x B 2 in the as-prepared LiH/MgB 2 materials. The presence of LiH dramatically improves the hydrogenation of MgB 2 at 700 bar, forming borohydride 100 °C below the minimum hydrogenation temperature of pure MgB 2 and without the formation of undesirable intermediates such as [B 3 H 8 ] - , [B 10 H 10 ] 2- or [B 12 H 12 ] 2- . Evidence is reported for a mixed-metal borohydride of the type Mg (3-x)/2 Li x (BH 4 ) 3 produced by the hydrogenation. Subsequent desorption is also improved compared to pure Mg(BH 4 ) 2 and LiBH 4 , showing single-step hydrogen release up to ~8 wt% by 380 °C, whereas Mg(BH 4 ) 2 and LiBH 4 still retain significant amounts of hydrogen at this temperature. The material produced by desorption contains both MgB 2 and Mg metal, revealing the original LiH/MgB 2 system is not fully reversible. In contrast to LiH, TiH 2 is essentially inert when ball-milled with MgB 2 , and high-pressure hydrogenation leaves only unreacted TiH 2 and MgB 2 . Thus, added TiH 2 provides no benefit to MgB 2 hydrogenation.

08 HYDROGEN↗

Hydrogen production from full-strength corn stover fermentation effluent in single-chamber replaceable-cathode microbial electrolysis cells

Lignocellulosic residual biomass generated by the agricultural sector is an abundant feedstock for biohydrogen production via dark fermentation. However, this process is intrinsically inefficient, converting only ~30% of the reductant energy into H2 and leaving substantial amounts of reduced byproducts. These byproducts, mostly found in the fermentation effluents, can be further valorized in microbial electrolysis cells (MECs) to enhance the overall H2 recovery. However, current MEC configurations are typically dual- or single-chamber systems, yet both suffer from key inefficiencies. Dual-chamber systems rely on proton exchange membranes that are costly and prone to rapid biofouling, whereas single-chamber, membraneless systems are limited by reduced productivity due to H2 recycling and methanogenic consumption In this study, three single-chamber, 50-mL replaceable-cathode microbial electrolysis cells (RC-MECs) were 3D-printed and equipped with a physical separator to isolate anode and cathode compartments and limit H2 migration. Full-strength milled corn stover (MCS) fermentation effluent (COD of ~23.8 g-COD/L) was treated in fed-batch mode over two operational periods spanning 21 (Run 1) and 80 (Run 2) days. The RC-MECs exhibited comparable performance in both runs: after biofilm maturation, current densities exceeded 100 A/m²_cathode, COD removal reached up to 43%. Notably, extended RC-MECs operation led to a substantial methanogenic activity with the CH4 fraction in the cathode gas increasing to as high as 80% of the total biogas. Additions of a methanogenesis inhibitor 2-bromoethanesulfonate (2-BES) produced transient increases in hydrogen yields (11.51 and 5.12 L-H2/L_reactor/day in Runs 1 and 2, respectively); however, sustained 2-BES addition in subsequent cycles reduced total biogas production, decreased COD removal, and led to volatile fatty acid accumulation. Overall, single-chamber MECs can treat high-strength dark fermentation effluents while improving H2 recovery, but methanogenesis remains a key bottleneck, and complete long-term inhibition may be operationally unsustainable.

Hydrogen Production↗

Solid face sheets enable lattice metamaterials to withstand high-amplitude impulsive loading without yielding

Owing to their ability to provide tunable mechanical responses, lattice materials are frequently studied to elucidate their response to static and dynamic loads. However, these roles are typically in opposition: static loads must be supported sufficiently far away from the onset of buckling or yielding, whereas dynamic loads are typically ameliorated by crushing of the lattice, which provides excellent energy-absorption due to the large plastic deformation accompanying densification. In contrast, this work considers the octet truss as an exemplar topology, in a structural role where it must simultaneously support static loads while enduring high-amplitude impulsive loads. This study focuses on the ability to withstand impulsive loads without yielding, an essential prerequisite to enduring dual loading. Computational studies using the ALE3D hydrocode were performed to examine the response of the octet truss under a short temporal width impulse shape associated with laser-driven shocks. A key finding was that covering the lattice with a solid face sheet and treating this face sheet thickness as a design variable allows the Taylor-like pulse to be attenuated prior to entering the weaker lattice, at the cost of added mass up front. Experimental validation was accomplished by laser-driven shock testing, using octet trusses printed out of Ti-5Al-5V-5Mo-3Cr. The results show that for a given quantity of mass, the attenuation is maximized when as much mass as possible is moved into the face sheet, leaving a more slender lattice structure. The effect of placing mass in the face sheet rather than lattice beams dominates the effect of relative density, to the point where a low-mass structure with most of the mass concentrated in the face sheet can outperform a high-mass structure with most of the mass in the lattice. Finally, by further understanding the propagation of short pulse width waves within under-dense structures, this study expand the domain of applicability of such structures, including lattice materials, to challenging dual-loading regimes spanning decades of strain rates.

36 MATERIALS SCIENCE↗

Discrete stochastic model of point defect-dislocation interaction for simulating dislocation climb

Dislocation climb is an important high temperature process in metals plasticity, responsible for the phenomena such as creep, swelling, or hardening. Climb is defined by the ability of dislocations to leave their original glide plane by interacting with point defects. As such, dislocation climb is controlled by point defect diffusion/absorption/emission, all of which involve thermal activation. The existing thermodynamically consistent models for climb are generally formulated in a continuum framework, through the definition of effective defect fluxes and climb propensities in response to thermodynamic driving forces. However, the point-wise discrete nature of vacancies (and/or self-interstitials) confers a highly discrete nature to the climb dynamics, which is also strongly affected by elastic forces. The combination of discreteness, thermal activation, and elasticity makes this process too challenging for direct atomistic methods such as molecular dynamics. Here we develop a kinetic Monte Carlo model that captures vacancy generation and transport kinetics acting in conjuction with the evolving elastic fields provided by discrete dislocation dynamics simulations. The two models are coupled via the applied stresses and stress gradients generated by dislocation structures at vacancy locations. Our simulations reveal two surprising results. First that climb is dominated by vacancy emission even when the background vacancy concentration is much higher than the equilibrium one. And, second, that climb velocities might be much faster than otherwise believed when one uses the classical theories of climb. These effects are due to the locality of vacancy-dislocation processes, which are not captured in classical treatments that assume smooth vacancy fluxes and homogeneous concentrations. We apply the method to study elementary climb processes in body-centered cubic iron and furnish climb mobility functions to be used in parametric dislocation dynamics and/or crystal plasticity simulations. Here, we apply the technique to study non-conservative plastic bypass of spherical precipitates by edge dislocations and point out the differences between our discrete approach and existing continuum formulations.

36 MATERIALS SCIENCE↗

Offering a Treatment Choice in the Irradiation of Prostate Cancer Leads to Better Informed and More Active Patients, Without Harm to Well-Being

Purpose: To examine, in prostate cancer patients, the effect of (1) being offered a choice between radiation doses in three-dimensional conformal radiotherapy, and of (2) accepting or declining the possibility to choose. Methods and Materials: A total of 150 patients with localized prostate cancer (T1-3N0M0) were offered a choice with a decision aid between two radiation doses (70 and 74 Gy). A control group of 144 patients received a fixed radiation dose without being offered a choice. Data were collected at baseline (before choice), before treatment (after choice), and 2 weeks and 6 months after treatment completion. Results: Compared with the control group, the involvement group, receiving the decision aid, showed increased participation in decision making (p < 0.001), increased knowledge (p < 0.001), and improved risk perception (p < 0.001); they were more satisfied with the quality of information (p = 0.002) and considered their treatment a more appropriate treatment (p = 0.01). No group differences were found in well-being (e.g., general health, European Organization for Research and Treatment of Cancer quality of life, anxiety). Within the involvement group, accepting or declining the option to choose did not affect well-being either. Conclusions: Offering a choice of radiation dose, with a decision aid, increased involvement in decision making and led to a better-informed patient. In contrast to earlier suggestions, a strong increase in involvement did not result in improved well-being; and in contrast to clinical concerns, well-being was not negatively affected either, not even in those patients who preferred to leave the decision to their physician. This study shows that older patients, such as prostate cancer patients, can be informed and involved in decision making.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multileaf Collimator Characteristics and Reliability Requirements for IMRT Elekta System

Understanding the characteristics of a multileaf collimator (MLC) system, modeling MLC in a treatment planning system, and maintaining the mechanical accuracy of the linear accelerator gantry head system are important factors in the safe implementation of an intensity-modulated radiotherapy program. We review the characteristics of an Elekta MLC system, discuss the necessary MLC modeling parameters for a treatment planning system, and provide a novel method to establish an MLC leaf position quality assurance program. To perform quality assurance on 40 pairs of individual MLC leaves is a time-consuming and difficult task. In this report, an effective routine MLC quality assurance method based on the field edge of a backup jaw as referenced in conjunction with a diode array as a radiation detector system is discussed. The sensitivity of this test for determining the relative leaf positions was observed to be better than 0.1 mm. The Elekta MLC leaf position accuracy measured with this system has been better than 0.3 mm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Postoperative Spot-Scanning Proton Radiation Therapy for Chordoma and Chondrosarcoma in Children and Adolescents: Initial Experience at Paul Scherrer Institute

Purpose: To evaluate postoperative spot-scanning proton radiation therapy (PT) and intensity-modulated PT (IMPT) for chordoma and chondrosarcoma in pediatric patients. Methods and Materials: Between 2000 and 2005, 10 patients (six male patients, four female patients; six chordomas, four chondrosarcomas), aged 10-20 years (median, 16 years), were treated at our institute. Tumor sites were in the brain (one case), skull base (five cases), cervical (three cases), and lumbar spine (one case). Three children had complete resections. In seven children, resection was incomplete, leaving residual tumor behind (range, 2.3-46.3 mL). PT was delivered using spot scanning, with (three patients) or without (seven patients) IMPT. Total dose was 74.0 cobalt Gray equivalents (CGE) for chordoma, and 63.2-68.0 CGE for chondrosarcoma (median, 66.0), depending on histopathological grading and whether the patient had concurrent chemotherapy. Results: Median follow-up time was 36 months (range, 8-77 months). Radiation treatment was well tolerated. All patients remained failure-free at their last follow-up. Late adverse events were reported in three patients and were mild (neurosensory in one patient; alopecia and hypoaccusis in one patient) to moderate (one patient, Grade 2 pituitary insufficiency). Conclusions: Postoperative spot-scanning PT, delivered in combination with and without IMPT, for chordoma and chondrosarcoma in children and adolescents was tolerated without unacceptable adverse event and initial outcome is perfectly satisfactory in this small cohort. Longer follow-up time and larger cohort are needed to more fully assess tumor control, adverse events, as well as functional and cosmetic outcome.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Tumor Volume Changes on 1.5 Tesla Endorectal MRI During Neoadjuvant Androgen Suppression Therapy for Higher-Risk Prostate Cancer and Recurrence in Men Treated Using Radiation Therapy Results of the Phase II CALGB 9682 Study

Purpose: We prospectively determined whether the change in tumor volume (TV) during 2 months of neoadjuvant androgen suppression therapy (nAST) measured using conventional 1.5 Tesla endorectal magnetic resonance imaging (eMRI) was associated with the risk of recurrence after radiation (RT) and 6 months of AST. Patients and Methods: Between 1997 and 2001, 180 men with clinical stage T1c-T3cN0M0 adenocarcinoma of the prostate were registered. Fifteen were found to be ineligible and the institutional MR radiologist could not assess the TV in 32, leaving 133 for analysis. Multivariable Cox regression analysis was used to assess whether a significant association existed between eMRI-defined TV progression during nAST and time to recurrence adjusting for prostate-specific antigen (PSA) level, Gleason score (8 to 10 or 7 vs. 6 or less) and stage (T3 vs. T1-2). Results: After a median follow up of 6.7 years and adjusting for known prognostic factors, there was a significant increase in the risk of PSA failure (HR, 2.3 [95% CI, 1.1-4.5; p = 0.025) in men with eMRI-defined TV progression during nAST. Specifically, adjusted estimates of PSA failure were significantly higher (p = 0.032) in men with, compared with men without, eMRI-defined TV progression reaching 38% vs. 19%, respectively, by 5 years. Conclusion: Eradicating intraprostatic hormone refractory prostate cancer (HRPC) by maximizing local control and randomized trials assessing whether survival is improved when agents active against HRPC are combined with maximal local therapy are needed in men who progress based on eMRI during nAST.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Helical Tomotherapy Quality Assurance

Helical tomotherapy uses a dynamic delivery in which the gantry, treatment couch, and multileaf collimator leaves are all in motion during treatment. This results in highly conformal radiotherapy, but the complexity of the delivery is partially hidden from the end-user because of the extensive integration and automation of the tomotherapy control systems. This presents a challenge to the medical physicist who is expected to be both a system user and an expert, capable of verifying relevant aspects of treatment delivery. A related issue is that a clinical tomotherapy planning system arrives at a customer's site already commissioned by the manufacturer, not by the clinical physicist. The clinical physicist and the manufacturer's representative verify the commissioning at the customer site before acceptance. Theoretically, treatment could begin immediately after acceptance. However, the clinical physicist is responsible for the safe and proper use of the machine. In addition, the therapists and radiation oncologists need to understand the important machine characteristics before treatment can proceed. Typically, treatment begins about 2 weeks after acceptance. This report presents an overview of the tomotherapy system. Helical tomotherapy has unique dosimetry characteristics, and some of those features are emphasized. The integrated treatment planning, delivery, and patient-plan quality assurance process is described. A quality assurance protocol is proposed, with an emphasis on what a clinical medical physicist could and should check. Additionally, aspects of a tomotherapy quality assurance program that could be checked automatically and remotely because of its inherent imaging system and integrated database are discussed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Close or Positive Margins After Mastectomy for DCIS: Pattern of Relapse and Potential Indications for Radiotherapy

Purpose: Mastectomies result in very high local control rates for pure ductal carcinoma in situ; however, close or involved tumor margins are occasionally encountered. Data regarding the patterns of relapse in this setting are limited. Methods and Materials: Between 1994 and 2002, the pathology reports of 574 patients who had undergone mastectomy at our institution for pure ductal carcinoma in situ were retrospectively reviewed. Of the 574 patients, 84 were found to have margins of <10 mm. Of the 84 patients, 4 underwent postoperative radiotherapy and were excluded, leaving 80 patients for this analysis. Of the 80 patients, 31 had margins <2 mm and 49 had margins of 2.1-10 mm. High-grade disease was observed in 47 patients; 45 patients had comedonecrosis; and 30 had multifocal disease. Of the 80 patients, 51 were <60 years of age. Results: With a median follow-up of 61 months, 6 (7.5%) of the 80 patients developed local recurrence. Of the 31 patients with a margin of {<=}2 mm, 5 (16%) developed local recurrence vs. only 1 (2%) of 49 patients with a margin of 2.1-10 mm (p = 0.0356). Of the 6 patients with local recurrence, 5 had high-grade disease and/or comedonecrosis. All six recurrences were noted in patients <60 years old. Conclusion: The findings of this review suggest that patients with pure ductal carcinoma in situ who undergo mastectomy with a margin of <2 mm have a greater-than-expected incidence of local recurrence. Patients with additional unfavorable features such as high-grade disease, comedonecrosis, and age <60 years are particularly at risk of local recurrence. These patients might benefit from postmastectomy radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Commissioning of Volumetric Modulated Arc Therapy (VMAT)

Purpose: Volumetric modulated arc therapy (VMAT) involves the simultaneous use of dynamic multileaf collimator (DMLC) techniques and gantry arcing; appropriate quality assurance is therefore required. This article describes the development and implementation of procedures for commissioning VMAT on a commercial linear accelerator (Elekta PreciseBeam VMAT with MLCi and Beam Modulator heads). Materials and Methods: Tests for beam flatness and symmetry at the variable dose rates required for VMAT were performed. Multileaf collimator (MLC) calibration was investigated using dynamic prescriptions. The cumulative dose delivered by a sliding window aperture was measured and compared with calculated values. Rotational accuracy was evaluated using dynamic prescriptions which required accurate correlated motion of both gantry and MLC leaves. Finally, measured and calculated dose distributions for complete VMAT treatment plans were compared and evaluated. Results: Beam symmetry was found to be better than 3% down to dose rates of 75 MU/min. MLC calibration provided continuity of dose at match planes of better than 4%, which was comparable to interleaf leakage effects. Integrated sliding window doses were within 3% of those calculated. Tests for rotational accuracy showed uniformity of peripheral dose mostly within {+-}4% of local control point dose, or approximately {+-}0.2% of total central dose. A two-arc prostate case showed an absolute dose difference between calculations and measurements of less than 3%, with gamma (3% and 3 mm) of better than 95%. Conclusions: VMAT has been successfully commissioned and has been introduced into clinical use. The Elekta DMLC has also been shown to be suitable for sliding window delivery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Four-Dimensional Intensity-Modulated Radiotherapy Planning for Dynamic Multileaf Collimator Tracking Radiotherapy

Purpose: To develop a four-dimensional intensity-modulated radiotherapy (IMRT) planning method for dynamic multileaf collimator (DMLC)-based tumor tracking that takes respiratory motion into consideration. Methods and Materials: Using the concept of optimal deformation, a series of apertures are placed at different phases in the same segment to ensure maximally similar dose contributions at various anatomic points. We used a direct aperture optimization method to find a set of segments that achieved an optimal dose distribution for aperture shapes at the reference phase and achieved corresponding optimal deformations at other phases that took respiratory motion into consideration. In our four-dimensional direct aperture optimization (4D-DAO) method, a simulated annealing algorithm and a conjugate gradients algorithm were used to optimize the shape of the segments and the monitor units, respectively. We then compared the optimization results for three-dimensional conformal radiotherapy and 4D-DAO based on a set of simulated respiration 4D computed tomography (4DCT) data and a set of real 4DCT data. Results: Dosimetric analysis indicated that, compared with the 3DCRT method, the dose distribution is significantly improved when the optimal deformation tracking technique is used, even when the maximum velocity limit of the DMLC leaves is set. Conclusions: The proposed 4D-IMRT planning method can find a set of segments and the corresponding leaf movements, which can trace the tumor motion and thus protect more normal tissue from radiation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

First Demonstration of Combined kV/MV Image-Guided Real-Time Dynamic Multileaf-Collimator Target Tracking

Purpose: For intrafraction motion management, a real-time tracking system was developed by combining fiducial marker-based tracking via simultaneous kilovoltage (kV) and megavoltage (MV) imaging and a dynamic multileaf collimator (DMLC) beam-tracking system. Methods and Materials: The integrated tracking system employed a Varian Trilogy system equipped with kV/MV imaging systems and a Millennium 120-leaf MLC. A gold marker in elliptical motion (2-cm superior-inferior, 1-cm left-right, 10 cycles/min) was simultaneously imaged by the kV and MV imagers at 6.7 Hz and segmented in real time. With these two-dimensional projections, the tracking software triangulated the three-dimensional marker position and repositioned the MLC leaves to follow the motion. Phantom studies were performed to evaluate time delay from image acquisition to MLC adjustment, tracking error, and dosimetric impact of target motion with and without tracking. Results: The time delay of the integrated tracking system was {approx}450 ms. The tracking error using a prediction algorithm was 0.9 {+-} 0.5 mm for the elliptical motion. The dose distribution with tracking showed better target coverage and less dose to surrounding region over no tracking. The failure rate of the gamma test (3%/3-mm criteria) was 22.5% without tracking but was reduced to 0.2% with tracking. Conclusion: For the first time, a complete tracking system combining kV/MV image-guided target tracking and DMLC beam tracking was demonstrated. The average geometric error was less than 1 mm, and the dosimetric error was negligible. This system is a promising method for intrafraction motion management.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Comparison of Volumetric Modulated Arc Therapy and Conventional Intensity-Modulated Radiotherapy for Frontal and Temporal High-Grade Gliomas

Purpose: Volumetric modulated arc therapy (VMAT), the predecessor to Varian's RapidArc, is a novel extension of intensity-modulated radiotherapy (IMRT) wherein the dose is delivered in a single gantry rotation while the multileaf collimator leaves are in motion. Leaf positions and the weights of field samples along the arc are directly optimized, and a variable dose rate is used. This planning study compared seven-field coplanar IMRT (cIMRT) with VMAT for high-grade gliomas that had planning target volumes (PTVs) overlapping organs at risk (OARs). Methods and Materials: 10 previously treated patients were replanned to 60 Gy in 30 fractions with cIMRT and VMAT using the following planning objectives: 98% of PTV covered by 95% isodose without violating OAR and hotspot dose constraints. Mean OAR doses were maximally decreased without reducing PTV coverage or violating hotspot constraints. We compared dose-volume histogram data, monitor units, and treatment times. Results: There was equivalent PTV coverage, homogeneity, and conformality. VMAT significantly reduced maximum and mean retinal, lens, and contralateral optic nerve doses compared with IMRT (p < 0.05). Brainstem, chiasm, and ipsilateral optic nerve doses were similar. For 2-Gy fractions, mean monitor units were as follows: cIMRT = 789 +- 112 and VMAT = 363 +- 45 (relative reduction 54%, p = 0.002), and mean treatment times (min) were as follows: cIMRT = 5.1 +- 0.4 and VMAT = 1.8 +- 0.1 (relative reduction 65%, p = 0.002). Conclusions: Compared with cIMRT, VMAT achieved equal or better PTV coverage and OAR sparing while using fewer monitor units and less time to treat high-grade gliomas.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Identification of Genes Associated With Progression and Metastasis of Advanced Cervical Cancers After Radiotherapy by cDNA Microarray Analysis

Purpose: To identify a set of genes related to the progression and metastasis of advanced cervical cancer after radiotherapy and to establish a predictive method. Methods and Materials: A total of 28 patients with cervical cancer (15 stage IIIB, 13 stage IVA patients) who underwent definitive radiotherapy between May 1995 and April 2001 were included in this study. All patients were positive for human papillomavirus infection and harbored the wild-type p53 gene. The expression profiles of 14 tumors with local failure and multiple distant metastasis and 14 tumors without metastasis (cancer free) obtained by punch biopsy were compared before treatment, using a cDNA microarray consisting of 23,040 human genes. Results: Sixty-three genes were selected on the basis of a clustering analysis, and the validity of these genes was confirmed using a cross-validation test. The most accurate prediction was achieved for 63 genes (sensitivity, 78.8%; specificity, 38.1%). Some of these genes were already known to be associated with metastasis via chromosomal instability (TTK, BUB1B), extracellular matrix components (matrix metalloproteinase 1 [MMP-1]), and carcinogenesis (protein phosphatase 1 regulatory subunit 7 [PPP1R7]). A 'predictive score' system was developed that could predict the probability for development of metastases using leave-one-out cross-validation methods. Conclusions: The present results may provide valuable information for identified predictive markers and novel therapeutic target molecules for progression and metastasis of advanced cervical cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗