Search NASA⌕ Search

SEARCH · Search NASA

Results for “Measuring instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

Results From Mars Show Electrostatic Charging of the Mars Pathfinder Sojourner Rover

Indirect evidence (dust accumulation) has been obtained indicating that the Mars Pathfinder rover, Sojourner, experienced electrostatic charging on Mars. Lander camera images of the Sojourner rover provide distinctive evidence of dust accumulation on rover wheels during traverses, turns, and crabbing maneuvers. The sol 22 (22nd Martian "day" after Pathfinder landed) end-of-day image clearly shows fine red dust concentrated around the wheel edges with additional accumulation in the wheel hubs. A sol 41 image of the rover near the rock "Wedge" (see the next image) shows a more uniform coating of dust on the wheel drive surfaces with accumulation in the hubs similar to that in the previous image. In the sol 41 image, note particularly the loss of black-white contrast on the Wheel Abrasion Experiment strips (center wheel). This loss of contrast was also seen when dust accumulated on test wheels in the laboratory. We believe that this accumulation occurred because the Martian surface dust consists of clay-sized particles, similar to those detected by Viking, which have become electrically charged. By adhering to the wheels, the charged dust carries a net nonzero charge to the rover, raising its electrical potential relative to its surroundings. Similar charging behavior was routinely observed in an experimental facility at the NASA Lewis Research Center, where a Sojourner wheel was driven in a simulated Martian surface environment. There, as the wheel moved and accumulated dust (see the following image), electrical potentials in excess of 100 V (relative to the chamber ground) were detected by a capacitively coupled electrostatic probe located 4 mm from the wheel surface. The measured wheel capacitance was approximately 80 picofarads (pF), and the calculated charge, 8 x 10(exp -9) coulombs (C). Voltage differences of 100 V and greater are believed sufficient to produce Paschen electrical discharge in the Martian atmosphere. With an accumulated net charge of 8 x 10(exp -9) C, and average arc time of 1 msec, arcs can also occur with estimated arc currents approaching 10 milliamperes (mA). Discharges of this magnitude could interfere with the operation of sensitive electrical or electronic elements and logic circuits. Sojourner rover wheel tested in laboratory before launch to Mars. Before launch, we believed that the dust would become triboelectrically charged as it was moved about and compacted by the rover wheels. In all cases observed in the laboratory, the test wheel charged positively, and the wheel tracks charged negatively. Dust samples removed from the laboratory wheel averaged a few ones to tens of micrometers in size (clay size). Coarser grains were left behind in the wheel track. On Mars, grain size estimates of 2 to 10 mm were derived for the Martian surface materials from the Viking Gas Exchange Experiment. These size estimates approximately match the laboratory samples. Our tentative conclusion for the Sojourner observations is that fine clay-sized particles acquired an electrostatic charge during rover traverses and adhered to the rover wheels, carrying electrical charge to the rover. Since the Sojourner rover carried no instruments to measure this mission's onboard electrical charge, confirmatory measurements from future rover missions on Mars are desirable so that the physical and electrical properties of the Martian surface dust can be characterized. Sojourner was protected by discharge points, and Faraday cages were placed around sensitive electronics. But larger systems than Sojourner are being contemplated for missions to the Martian surface in the foreseeable future. The design of such systems will require a detailed knowledge of how they will interact with their environment. Validated environmental interaction models and guidelines for the Martian surface must be developed so that design engineers can test new ideas prior to cutting hardware. These models and guidelines cannot be validated without actual flighata. Electrical charging of vehicles and, one day, astronauts moving across the Martian surface may have moderate to severe consequences if large potential differences develop. The observations from Sojourner point to just such a possibility. It is desirable to quantify these results. The various lander/rover missions being planned for the upcoming decade provide the means for doing so. They should, therefore, carry instruments that will not only measure vehicle charging but characterize all the natural and induced electrical phenomena occurring in the environment and assess their impact on future missions.

Kolecki, Joseph C.↗

Studies on Laser Generated Ultrasonic Waves in Inconel Super Alloy

This paper deals with the generation, characterization and analysis of ultrasonic waves generated in a thick stepped sample of inconel super alloy using Laser Based Ultrasonic Technique. Nd-YAG pulsed laser is used for ultrasonic generation while He-Ne laser is used for heterodyne detection. Ultrasonic signals are analyzed using Fourier and wavelet transforms. Here the identification and estimation of velocity of pressure waves is presented. The mechanism of pressure wave generation is discussed in brief. Laser ultrasonics studies of inconel are being reported for the first time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Simons Observatory: A fully remote controlled calibration system with a sparse wire grid for cosmic microwave background telescopes

For cosmic microwave background (CMB) polarization observations, calibration of detector polarization angles is essential. We have developed a fully remote controlled calibration system with a sparse wire grid that reflects linearly polarized light along the wire direction. The new feature is a remote-controlled system for regular calibration, which has not been possible in sparse wire grid calibrators in past experiments. The remote control can be achieved by two electric linear actuators that load or unload the sparse wire grid into a position centered on the optical axis of a telescope between the calibration time and CMB observation. Furthermore, the sparse wire grid can be rotated by using a motor. A rotary encoder and a gravity sensor are installed on the sparse wire grid to monitor the wire direction. They allow us to achieve detector polarization angle calibration with an expected systematic error of 0.08°. The calibration system will be installed in small-aperture telescopes at Simons Observatory.

47 OTHER INSTRUMENTATION↗

Atmospheric Radiation Measurement (ARM) Aerosol Observing Systems (AOS) for Surface-Based In Situ Atmospheric Aerosol and Trace Gas Measurements

Aerosols alter Earth’s radiative budget both directly and indirectly through interaction with clouds. Continuous observations are required to reduce the uncertainties in climate models associated with atmospheric processing and the interactions between aerosols and clouds. Field observations of aerosols are a central component of the Atmospheric Radiation Measurement (ARM) Facility’s global measurements. The ARM mission goal is to “provide the climate research community with strategically located in situ and remote sensing observatories designed to improve the understanding and representation, in climate and earth system models, of clouds and aerosols as well as their interactions and coupling with the Earth’s surface.” Since 1996, ARM has met this goal by operating Aerosol Observing Systems (AOS) for in situ measurement of aerosols. Currently the five ARM AOSs are the most comprehensive field deployable aerosol systems in the United States. The AOS suite includes seven measurement classes: number concentration, size distribution, chemical composition, radiative and optical properties, hygroscopicity, trace gases, and supporting meteorological conditions. AOSs are designed as standardized measurement platforms to enable intercomparison across the ARM Facility for regional process studies within a global context. The instrumentation and measurement capabilities of the ARM AOSs, along with a history of their design and field deployments are presented here.

54 ENVIRONMENTAL SCIENCES↗

Pyrgeometer Calibration for DOE-Atmospheric System Research Program Using NREL Method (Presentation)

Presented at the DOE-Atmospheric System Research Program, Science Team Meeting, 15-19 March 2010, Bethesda, Maryland. The presentation: Pyrgeometer Calibration for DOE-Atmospheric System Research program using NREL Method - was presented by Ibrahim Reda and Tom Stoffel on March 15, 2010 at the 2010 ASR Science Team Meeting. March 15-19, 2010, Bethesda, Maryland.

47 OTHER INSTRUMENTATION↗

Scientific rationale and strategies for a first comet mission. Report of the Comet Halley science working group. An executive summary

The justification, scientific objectives, instrumentation, and strategy for a first comet mission are discussed. Topics include: mission target; rendezous, propulsion system requirements, measurement objectives, instrument capabilities for rendezvous and the tail probe payload, and backup missions if rendezvous with Halley's comet is not possible to achieve. Support research to be done by NASA is recommended.

Source record↗

Initial Shuttle external tank flight evaluation

The objective of this paper is to evaluate aerothermal flight measurements made on the Space Shuttle External Tank (ET) during its initial flights. The ETs have been adequately instrumented to measure various quantities during flight including heat transfer, pressure, and structural temperature. The flight data have been compared with mathematical models based on an extensive wind tunnel data base, realistic flowfields, and empirical heat-transfer relationships. An analysis of the results points out the validity of the current aeroheating methodology and existing data base, and identifies problem areas in the methodology as indicated by the flight data.

Praharaj, S. C.↗

The Relationship Of Size Distributions To Spectral (300 - 700 Nm) Extinction Parameterization Of Ambient In Situ Aerosols Measured During FIREX-AQ And The Influence Of Aerosol Composition

Hyperspectral (300 - 700 nm, 0.7 nm resolution) aerosol extinction spectra were measured at seven fires in six states in the western United States during the Fire Influence on Regional to Global Environments and Air Quality (FIREX-AQ) field campaign in July and August 2019. Obtained using an in situ aerosol sampling method, these spectra are directly comparable to other in situ aerosol measurements such as size distribution and composition. A previous deployment of the in situ Spectral Aerosol Extinction (SpEx) instrument that measured fine mode aerosols (50% size cut of 1.3 µm particle diameter) around the Korean peninsula showed that over this spectral range 2nd order polynomials provided a better fit to the logarithmically transformed spectra than linear fits (representative of Ångström exponents). The two fit parameters (a1, a2) of the polynomials are related to the classic Ångström exponent but provide additional information via their two-dimensional parameter space. The previous work was limited by the lack of commensurate size distribution information. Here, using the FIREX-AQ spectra set it is possible to expand on the previous analysis in three specific ways: 1) size distribution information is available to further elucidate how size distribution maps into (a1, a2) space, 2) the sampled size distributions include larger particles than the Korean study, and 3) the FIREX-AQ data set exhibits smoke-related spectral features in the UV part of the spectrum that are not present in background air nor were they observed previously in the Korean study. The UV spectral features are particularly intriguing as they likely arise from the absorption component of the extinction measurement and therefore may be related to composition. The relationships between the ambient in situ aerosol size distributions, the extinction spectra, and composition will be presented.

Carolyn Jordan↗

Methods for Validation and Intercomparison of Remote Sensing and In situ Ice Water Measurements: Case Studies from CRYSTAL-FACE and Model Results

Remote sensing observations, such as those from AURA, are necessary to understand the role of cirrus in determining the radiative and humidity budgets of the upper troposphere. Using these measurements quantitatively requires comparisons with in situ measurements that have previously been validated. However, a direct comparison of remote and in situ measurements is difficult due to the requirement that the spatial and temporal overlap be sufficient in order to guarantee that both instruments are measuring the same air parcel. A difficult as this might be for gas phase intercomparisons, cloud inhomogeneities significantly exacerbate the problem for cloud ice water content measurements. The CRYSTAL-FACE mission provided an opportunity to assess how well such intercomparisons can be performed and to establish flight plans that will be necessary for validation of future satellite instruments. During CRYSTAL-FACE, remote and in situ instruments were placed on different aircraft (NASA's ER-2 and WB-59, and the two planes flew in tandem so that the in situ payload flew in the field of view of the remote instruments. We show here that, even with this type of careful flight planning, it is not always possible to guarantee that remote and in situ instruments are viewing the same air parcel. We use ice water data derived from the in situ Harvard Total Water (HV-TW) instrument, and the remote Goddard Cloud Radar System (CRS) and show that agreement between HV-TW and CRS is a strong function of the horizontal separation and the time delay between the aircraft transects. We also use a cloud model to simulate possible trajectories through a cloud and evaluate the use of statistical analysis in determining the agreement between the two instruments. This type of analysis should guide flight planning for future intercomparison efforts, whether for aircraft or satellite-borne instrumentation.

Sayres, D.S.↗

A Near-Infrared Spectrometer to Measure Zodiacal Light Absorption Spectrum

We have developed a high throughput infrared spectrometer for zodiacal light fraunhofer lines measurements. The instrument is based on a cryogenic dual silicon Fabry-Perot etalon which is designed to achieve high signal to noise Fraunhofer line profile measurements. Very large aperture silicon Fabry-Perot etalons and fast camera optics make these measurements possible. The results of the absorption line profile measurements will provide a model free measure of the zodiacal Light intensity in the near infrared. The knowledge of the zodiacal light brightness is crucial for accurate subtraction of zodiacal light foreground for accurate measure of the extragalactic background light after the subtraction of zodiacal light foreground. We present the final design of the instrument and the first results of its performance.

Kutyrev, A. S.↗

Subdivision and direction recognition of {lambda}/16 of orthogonal fringes for nanometric measurement

Subdivision is one of the essential methods to improve the measurement resolution of optical instruments. A new method is proposed to solve {lambda}/16 bidirectional subdivision and direction recognition for orthogonal interference signals by constructing two sets of reference signals and using zero-cross detection. The experimental results prove that the method is efficient for orthogonal signals and has good real-time performance by field-programmable gate array realization. This method is easy to realize by use of electronic design automation tools and can be widely used in the signal processing system of optical measurement instruments such as a moire fringe measurement system and laser interferometer.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Multiple wavelength geodesy

An apparatus is being constructed which should be able to measure baselines up to 50 km long with a fractional uncertainty of about 5 x 10 to the -8 power. The instrument will measure both the optical length and the required correction due to the refractivity of the atmosphere, using three wavelengths transmitted in one direction over the path to an active receiver. The three wavelengths are 632.8 nm, 441.6 nm and 3.7 cm. The two endpoint instruments are synchronized using subsidiary return transmissions at 632.8 nm and another telemetry signal. The one-way nature of the system allows an increase in range over existing round-trip systems.

Levine, J.↗

Cold Plasma Measurements

We have continued the simulation campaign in support of our ongoing magnetospheric cold plasma research project. This project aims to develop the next-generation particle instruments to measure the properties of the cold particle populations in the Earth’s magnetosphere. For this purpose, simulations have been performed with a Particle-In-Cell (PIC) code called the Curvilinear PIC (CPIC). The code is formulated in curvilinear geometry and couples the standard PIC algorithm with algorithms for the generation and adaptation of the underlaying computational mesh. It conforms to complex objects like spacecraft and it can place more grid points in regions where higher resolution is needed. The code also features a scalable solver based on the multigrid algorithm and it is fully parallelized via domain decomposition and MPI.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fiber optic instrumentation for nuclear fuels and materials irradiations

The ability to predict the safety and reliability of new and advanced nuclear fuels and materials requires high-fidelity measurements during instrumented irradiation experiments. Optical fiber-based sensors are promising candidates for instrumentation in high-temperature (300-1200 C. degrees) irradiation environments, provided that signal attenuation due to radiation damage and/or high-temperature operation is not prohibitively large. To determine the feasibility of using silica optical fibers in instrumented irradiation capsules, a computational model has been developed to predict broadband optical attenuation in fused silica fiber materials as a function of time, temperature, and dose. Defect concentrations are calculated using a set of 11 coupled differential equations that include neutron-induced displacement, radiation-induced bond cleavage at precursor sites, and thermally-assisted molecular diffusion and defect recombination at elevated temperatures. Defect concentrations are coupled with the known optical properties of the various defects in fused silica to predict optical attenuation. The effects of radiation-induced compaction (i.e., formation of the 'metamict' phase) on the optical attenuation are also included. Results show that elevated temperatures significantly reduce attenuation resulting from defect centers (attenuation below ∼750 nm) as well as attenuation resulting from radiation-induced compaction (attenuation above ∼800 nm). The predicted attenuation is acceptable for most fiber optic-based sensor systems with a dynamic range on the order of 20-50 dB for a reasonable length (1-2 meters) of fiber in the high-flux region. Many optical components use a wavelength of 850 nm, which lies in the low-attenuation window. An irradiation campaign has been initiated to provide temperature-dependent optical attenuation data at high dose to validate the predictive model. (author)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

How are Heterogeneous Nucleation Rate Observations Influenced by Instrument Resolution?

Experimental measurements of the heterogeneous nucleation rate rely on counting the number of nuclei with time. However, the size of a thermodynamically stable nucleus is often a few nanometers in diameter and is below the resolution of most (in situ) measurement techniques that provide a statistically valid sample. Due to the finite resolution of the instruments and analysis methods, it is challenging to capture the incipient nuclei and the subsequent evolution of nuclei density over time. In this work, we demonstrate the impact of instrument resolution on observed nuclei densities by comparing numerical modeling with experimental results. Further, to achieve this, we implemented heterogeneous nucleation within the pore-scale reactive transport modeling framework using classical nucleation theory (CNT). We compared the modeling results with nucleation rates measured using X-ray nanotomography (XnT) and evaluated how these impact the apparent values of the prefactor and interfacial energy based on CNT and the crystal growth rate. Specifically, we applied a resolution threshold (artificial resolution limit) in the model during nuclei counting to resemble an experimental resolution, ranging from 15 to 500 nm. The findings reveal that the instrument resolution significantly impacts the apparent prefactor and interfacial energy. Both apparent prefactor and interfacial energy decrease with a decrease in the instrument resolution. While deviation in the prefactor due to resolution is anticipated, those in the interfacial energy are unexpected. The approach described here allows one to correct apparent nucleation rates that depend on the instrument’s resolution to derive “intrinsic” CNT parameters for the prefactor and interfacial energy.

47 OTHER INSTRUMENTATION↗

First results from plasma density measurements in the FTU tokamak by means of a two-frequency pulsed time-of-flight refractometer

A pulsed time-of-flight refractometer was developed and tested to determine the mean plasma density in the T-11M tokamak by measuring the propagation time of nanosecond microwave pulses in plasma. Later, it was also proposed to use such an instrument to measure and control the mean plasma density in the ITER tokamak by probing the plasma with an extraordinary wave, the electric field of which is perpendicular to the magnetic field in plasma, in the transparency window at frequencies of 50-100 GHz. To avoid the effect of the density profile shape on the measurement results in the nonlinear mode of refractometer operation (near the cutoff), a system operating at two different probing frequencies was developed and tested. Such a system provides two values of the time delay, which can be used to estimate the peaking factor of the density distribution {alpha} and correctly determine the linear density Left-Pointing-Angle-Bracket Nl Right-Pointing-Angle-Bracket , regardless of the density profile (assuming a smooth density profile of the form of N({rho}) = N(0)(1 - {rho}{sup 2}){sup {alpha}}, where N(0) is the central plasma density and {rho} = r/a is the normalized plasma radius). The first experiments on density measurements in the FTU tokamak performed with this refractometer are described, and results from these experiments are presented. The formation of a thin dense plasma layer in the zone of a strong magnetic field (the so-called MARFE layer) at a relatively low (for FTU) plasma density of {approx}6 Multiplication-Sign 10{sup 19} m{sup -3} was detected. The thickness of this layer, determined from the refractometry data, agrees well with the data obtained using a digital camera.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of the coastal zone color scanner for NIMBUS 7. Volume 1: Mission objectives and instrument description

An Earth scanning six channel (detector) radiometer using a classical Cassegrain telescope and a Wadsworth type grating spectrometer was launched aboard Nimbus 7 in order to determine the abundance or density of chlorophyll at or near the sea surface in coastal waters. The instrument also measures the sediment or gelbstroffe (yellow stuff) in coastal waters, detects surface vegetation, and measures sea surface temperature. Block diagrams and schematics are presented, design features are discussed and each subsystem of the instrument is described. A mission overview is included.

Source record↗