At least 1,567 records · Page 87

Fast neutron irradiation capability in existing thermal test reactors

In today’s nuclear industry, momentum towards the design, licensing, and construction of advanced nuclear demonstration plants, including fast reactors, is at a remarkably high level. However, there are currently no dedicated fast spectrum irradiation test facilities in the United States to support the development of fast spectrum technologies. As a result, a unique situation is developing where most of these plants will likely be designed by leveraging historic nuclear material technologies, but where the further optimization and advancement is impeded by the lack of fast neutron irradiation test facilities. While these circumstances present a challenge, there are some near-term opportunities that, if seized, can still help develop advanced fast reactor materials to a meaningful level of readiness to support future commercial fast reactors. Here, in this paper, we assess the feasibility of using thermal neutron filtering materials in existing experiment positions in the Advanced Test Reactor (ATR) at Idaho National Laboratory and the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory to simulate fast reactor test environments for nonfuel test specimens. Items investigated include the incident neutron flux (both fast and thermal), the total neutron fluence and cumulative atom displacements, helium production rate due to thermal neutron capture in nickel, and the potential impact that the thermal neutron filter material has on the cycle length of a given reactor. It is concluded that while HFIR provides the highest fast flux of all the options investigated, it is limited in the amount of thermal neutron filtering material that can be introduced into an experiment position without significantly affecting the operation of the reactor. Irradiation in Outboard-A positions in the ATR was found to be the most realistic near-term experiment avenue due to having ample space for several capsules in a moderately fast flux.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Thermal–hydraulic–mechanical modeling of a large-scale heater test to investigate rock salt and crushed salt behavior under repository conditions for heat-generating nuclear waste

The Thermal Simulation for Drift Emplacement heater test is modeled with two simulators for coupled thermal-hydraulic-mechanical processes. Results from the two simulators are in very good agreement. The comparison between measurements and numerical results is also very satisfactory, regarding temperature, drift closure and rock deformation. Concerning backfill compaction, a parameter calibration through inverse modeling was performed due to insufficient data on crushed salt reconsolidation, particularly at high temperatures. We conclude that the two simulators investigated have the capabilities to reproduce the data available, which increases confidence in their use to reliably investigate disposal of heat-generating nuclear waste in saliferous geosystems.

58 GEOSCIENCES↗

Methods, software and datasets to verify DVH calculations against analytical values: Twenty years late(r)

Purpose: The authors designed data, methods, and metrics that can serve as a standard, independent of any software package, to evaluate dose-volume histogram (DVH) calculation accuracy and detect limitations. The authors use simple geometrical objects at different orientations combined with dose grids of varying spatial resolution with linear 1D dose gradients; when combined, ground truth DVH curves can be calculated analytically in closed form to serve as the absolute standards. Methods: DICOM RT structure sets containing a small sphere, cylinder, and cone were created programmatically with axial plane spacing varying from 0.2 to 3 mm. Cylinders and cones were modeled in two different orientations with respect to the IEC 1217 Y axis. The contours were designed to stringently but methodically test voxelation methods required for DVH. Synthetic RT dose files were generated with 1D linear dose gradient and with grid resolution varying from 0.4 to 3 mm. Two commercial DVH algorithms—PINNACLE (Philips Radiation Oncology Systems) and PlanIQ (Sun Nuclear Corp.)—were tested against analytical values using custom, noncommercial analysis software. In Test 1, axial contour spacing was constant at 0.2 mm while dose grid resolution varied. In Tests 2 and 3, the dose grid resolution was matched to varying subsampled axial contours with spacing of 1, 2, and 3 mm, and difference analysis and metrics were employed: (1) histograms of the accuracy of various DVH parameters (total volume, D{sub max}, D{sub min}, and doses to % volume: D99, D95, D5, D1, D0.03 cm{sup 3}) and (2) volume errors extracted along the DVH curves were generated and summarized in tabular and graphical forms. Results: In Test 1, PINNACLE produced 52 deviations (15%) while PlanIQ produced 5 (1.5%). In Test 2, PINNACLE and PlanIQ differed from analytical by >3% in 93 (36%) and 18 (7%) times, respectively. Excluding D{sub min} and D{sub max} as least clinically relevant would result in 32 (15%) vs 5 (2%) scored deviations for PINNACLE vs PlanIQ in Test 1, while Test 2 would yield 53 (25%) vs 17 (8%). In Test 3, statistical analyses of volume errors extracted continuously along the curves show PINNACLE to have more errors and higher variability (relative to PlanIQ), primarily due to PINNACLE’s lack of sufficient 3D grid supersampling. Another major driver for PINNACLE errors is an inconsistency in implementation of the “end-capping”; the additional volume resulting from expanding superior and inferior contours halfway to the next slice is included in the total volume calculation, but dose voxels in this expanded volume are excluded from the DVH. PlanIQ had fewer deviations, and most were associated with a rotated cylinder modeled by rectangular axial contours; for coarser axial spacing, the limited number of cross-sectional rectangles hinders the ability to render the true structure volume. Conclusions: The method is applicable to any DVH-calculating software capable of importing DICOM RT structure set and dose objects (the authors’ examples are available for download). It includes a collection of tests that probe the design of the DVH algorithm, measure its accuracy, and identify failure modes. Merits and applicability of each test are discussed.

60 APPLIED LIFE SCIENCES↗

LIHE Spectral Dynamics and Jaguar Data Acquisition System Measurement Assurance Results 2014

The Light Initiated High Explosive (LIHE) facility performs high rigor, high consequence impulse testing for the nuclear weapons (NW) community. To support the facility mission, LIHE's extensive data acquisition system (DAS) is comprised of several discrete components as well as a fully integrated system. Due to the high consequence and high rigor of the testing performed at LIHE, a measurement assurance plan (MAP) was developed in collaboration with NW system customers to meet their data quality needs and to provide assurance of the robustness of the LIHE DAS. While individual components of the DAS have been calibrated by the SNL Primary Standards Laboratory (PSL), the integrated nature of this complex system requires verification of the complete system, from end-to-end. This measurement assurance plan (MAP) report documents the results of verification and validation procedures used to ensure that the data quality meets customer requirements.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Performance Testing of Software Upgrade for SRNL CPC Instrument at the Nuclear Material Laboratory, Office of Safeguards Analytical Services, International Atomic Energy Agency

This report summarizes the performance testing for the Software upgrade for the Savannah River National Laboratory (SRNL) Controlled Potential Coulometry (CPC) instrument. This upgrade is specifically to meet the needs of the Nuclear Material Laboratory, Office of Safeguards Analytical Services, International Atomic Energy Agency at Seibersdorf, Austria. The instrument hardware was upgraded in 2010, but the software continued to operate on a Windows platform using a High Tech Basic (HT Basic) application. HT Basic usage is declining. The IAEA requested an upgrade to the existing coulometer software to Laboratory Virtual Instrument Engineering Workbench (LabVIEW), an object-oriented programming language in wide use and one the NML staff is familiar with. The software was developed by SRNL Software Engineer, with assistance from Electrical Engineer and Scientist. Once developed, the new LabVIEW software was validated, tested with Iron (surrogate for plutonium) and plutonium. Once testing was completed, the software was installed at the International Atomic Energy Agency Nuclear Material Laboratory (IAEA NML) coulometer, and SRNL provided hands on training to NML staff on using the new software.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Use of Micro-Gravity Sensors for External Fluid Level Monitoring in Waste and Nuclear Related Applications - 20315

There are a number of applications in nuclear energy and hazardous waste disposal that require monitoring of fluids under extreme environments, including high levels of temperature, pressure, toxicity and radioactivity. Many of these applications will benefit from a monitoring technique that is external and non-invasive. Currently the sensors used are invasive, must reside inside the pressurized vessels and must penetrate the vessel walls, which can create a weakness in the vessel. Additionally, instruments that are used inside such containers must be exceptionally hardened to the environment. Information Systems Laboratories (ISL) has developed an external mass (gravimetric) measuring technique for monitoring nuclear coolant in Small Modular Reactors (SMRs), which will also work for measuring fluid levels in waste tanks, that avoids the problems inherent in invasive sensors. It utilizes a COTS gravitational sensor of unprecedented accuracy, leveraged via proper sensor placement geometry, to detect fluid changes of small amplitude from an outside position, obviating the need to penetrate the vessel. The technique is called Gravisense{sup TM}. ISL has proven via simulation and experiment that this concept can be usefully applied to monitoring fluid levels in both nuclear reactors and large waste tanks. Numerical simulation algorithms were developed to calculate the gravity effect of small changes in water level, which were verified by experiments at the NIST Physical Simulator facility at the Oregon State University. The measured ultralow noise levels of the superconducting gravimeter type which utilizes a Niobium sphere suspended in a magnetic field to attain its phenomenal accuracy, demonstrated that fluid levels in SMRs can be measured at least to within 3 cm. Furthermore, the method can distinguish between a contained leak (from reactor to containment vessel) from an external leak (from reactor to outside of containment). Additionally, simulations of waste canisters that hold spent fuel rods show that the fluid level measuring accuracy can potentially do better than 1 cm accuracy by measuring from below the vessel, and judicious placement of sensors on top of large waste tanks can potentially achieve a very impressive 2 mm measurement accuracy. These encouraging results prove that the Gravisense{sup TM} technique for fluid determination can be very useful in nuclear energy generation, testing, and research, as well as in waste monitoring situations that are difficult to monitor via traditional sensing technology. We believe that the next step should be to test the technique on canisters of the type that are currently storing waste in various DOE locations. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The Atomic Cannon: Upshot-Knothole Grable

The May 25, 1952, Upshot-Knothole Grable event, aka Atomic Annie, proof tested a tactical nuclear weapon fashioned into a 280 mm cannon shell and fired from the Army’s M65 artillery piece. Travelling nearly seven miles downrange, Grable detonated with a force of fifteen kilotons 500 feet over a dry lake bed on the Nevada Test Site known as Frenchman Flat.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

An analysis method for experiment power in the ATR

The Advanced Test Reactor (ATR) at Idaho National Laboratory (INL) is used for testing and qualification of nuclear fuels and materials. The ATR has been irradiating the lead test assembly (LTA) for the planned Ki-Jang Research Reactor (KJRR) in Korea. Irradiation and subsequent Post-Irradiation Examination (PIE) of the LTA will lead to qualification of the fuel to support licensing activities. Qualification of the LTA requires the experiment to meet specific thermal and burn-up conditions. In particular, plate 20 of the experiment must obtain a heat flux between 137 and 200 W/cm{sup 2} with a target U-235 depletion of 79-84%. Due to the limited instrumentation and burn-up monitoring capabilities, assurance of meeting experiment goals is verified through modelling. In order to validate the experiment model using ATR operating data, a methodology was developed to compare the calculated experiment power with ATR power monitoring instrumentation. This paper discusses the methodology used to quantify the experiment power and uncertainty in the model based on ATR operating conditions. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Molar Absorptivities of U(VI), U(IV), and Pu(III) in Nitric Acid Solutions of Various Concentrations Relevant to Developing Nuclear Fuel Recycling Flowsheets

Testing of a co-decontamination (CoDCon) tributyl phosphate (TBP) based solvent extraction flowsheet is being performed to optimize conditions for achieving a target U/Pu ratio in the Pu-containing product. The flowsheet is designed to directly produce a mixture of U and Pu with a U/Pu mass ratio of 7/3. The system is monitored in real time using optical spectroscopy, which allows for control of the U/Pu ratio in the aqueous U/Pu nitrate product. On-line spectrophotometric monitoring of the aqueous stream at the reductive stripping step involves determination of U(VI), U(IV) and Pu(III) concentrations and relies on molar absorptivities of these species in nitric acid at a number of wavelengths corresponding to their peaks’ maxima. The magnitudes of these molar absorptivities are a sensitive function of nitric acid concentration and have to be determined as precisely as possible using an off-line spectrophotometry under well controlled conditions. This step (called training set acquisition) is typically performed not in a high contamination area of radiological glovebox where flow-through cells and other on-line equipment are installed but in a less aggressive environment of a radiological fume hood with much better control of stock solutions quality, dilution factors, optical absorbance scale calibration, etc. This is followed by the calibration transfer between the off-line instrument and the instrument deployed during extraction and stripping runs. This paper reports values of molar absorptivities of U(VI), U(IV), and Pu(III) in nitric acid solution of 0.5 M to 4 M concentration and compares them with available technical literature data. Results of off-line spectrophotometric analysis of selected aqueous grab samples from one of CoDCon runs show satisfactory agreement with total uranium and plutonium concentrations determined in the same samples by ICP-MS.

Sinkov, Sergey I.↗

Formulation and testing of a high-tin borosilicate nuclear waste glass for in-can melting

Here, borosilicate waste glasses were successfully developed to immobilize two high-level waste raffinate streams via an in-can melter process with an Inconel 601 canister at 1050 °C. Measured viscosity and crystallinity thermal profiles were within the targeted processing constraints for the in-can melter process. Measured chemical durability of the glass by ASTM C1285–21 (Method A), ranged from normalized loss of boron, NL(B) = 1.44 – 2.65 g•m -2 , and NL(B) decreased with increased waste loading, accompanied by increased SnO 2 crystallinity. Measured corrosion of the in-can melter canister by a glass melt showed that Inconel 601 performed well at 1100 °C for up to 500 hr. Resistance polarization measurements versus time revealed that Inconel 601 corrosion rates in (and by) glass melts decreased from an initial rate of 63 mm•y -1 down to 10.2 mm•y -1 after 137 h with increased duration, which was attributed to formation of an oxide passivation layer (mainly Cr 2 O 3 ) at the alloy-glass interface.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Coupling coarse-mesh CFD with fine-mesh CFD for modeling molten-salt reactors in the Virtual Test Bed (VTB)

The Nuclear Energy Advanced Modeling and Simulation (NEAMS) program aims at developing a simulation tool kit to accelerate the development and deployment of nuclear power technologies. NEAMS multiphysics tools have been designed to provide numerical simulation support for the design and licensing of GEN IV reactors. Pronghorn is NEAMS's coarse-mesh computational fluid dynamics (CFD) tool, which is designed to run 3D core transients in GEN IV reactors at a reduced computational cost. To increase their accuracy, coarse-mesh CFD simulations require calibrated closure coefficients. One way of computing these coefficients is via the Nek5000, NEAMS's high-fidelity CFD tool. This article discusses our current research lines in informing Pronghorn closure coefficients via Nek5000 to enable multiphysics simulations of the core cavity of the molten-salt fast reactor. We present an application in which Pronghorn mixing length turbulent viscosity has been calibrated from Nek5000 simulations. The resulting Pronghorn thermal-hydraulics model is then coupled to Griffin, the NEAMS neutron transport solver, to solve for the steady-state configuration of the molten-salt fast reactor. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗