Search NASA⌕ Search

SEARCH · Search NASA

Results for “Optical signal processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

Simulated Feasibility of 3-D Lightning Mapping From Space

In addition to the awe it inspires, lightning can illuminate the microphysical processes hidden away within deep convection. The current generation of space-based lightning mapping uses mostly 2-D optical imaging to connect overall flash characteristics to their parent storm dynamics, but are missing a dimension’s worth of information. With lightning now classified as an essential climate variable, future spaceborne mappers will need improved capabilities to take advantage of the 3-D structure of lightning flashes to support meteorological and climate modeling. We report here on a study of the feasibility of high-resolution 3-D lightning mapping using a radio frequency (RF)-based network of satellites from low-Earth orbit (LEO). Lightning sources are simulated using existing lightning mapping array (LMA) tools, modified for orbital detection, and spatially reconstructed using a Levenberg–Marquardt geolocation algorithm to assess sources of uncertainty in these solutions. We analyze the benefits and limitations of this approach compared to existing orbital and ground-based methods. Results of this study show that lightning can be mapped in 3-D with a vertical location accuracy better than 2 km using as few as five satellites in LEO capable of measuring the time-of-arrival of impulsive RF signals in the very high-frequency (VHF) band. The consequence of this study is that high-resolution, spaceborne 3-D mapping of lightning is achievable across most of the globe, having crucial implications for our understanding of not only lightning, but also severe weather development, climate science, and more.

47 OTHER INSTRUMENTATION↗

Suppressing Loss of Ions in an Atomic Clock

An improvement has been made in the design of a compact, highly stable mercury- ion clock to suppress a loss of ions as they are transferred between the quadrupole and higher multipole ion traps. Such clocks are being developed for use aboard spacecraft for navigation and planetary radio science. The modification is also applicable to ion clocks operating on Earth: indeed, the success of the modification has been demonstrated in construction and operation of a terrestrial breadboard prototype of the compact, highly stable mercury-ion clock. Selected aspects of the breadboard prototype at different stages of development were described in previous NASA Tech Briefs articles. The following background information is reviewed from previous articles: In this clock as in some prior ion clocks, mercury ions are shuttled between two ion traps, one a 16- pole linear radio-frequency trap, while the other is a quadrupole radio-frequency trap. In the quadrupole trap, ions are tightly confined and optical state selection from a 202Hg lamp is carried out. In the 16-pole trap, the ions are more loosely confined and atomic transitions are interrogated by use of a microwave beam at approximately 40.507 GHz. The trapping of ions effectively eliminates the frequency pulling that would otherwise be caused by collisions between clock atoms and the wall of a gas cell. The shuttling of the ions between the two traps enables separation of the state-selection process from the clock microwave-resonance process, so that each of these processes can be optimized independently of the other. This is similar to the operation of an atomic beam clock, except that with ions the beam can be halted and reversed as ions are shuttled back and forth between the two traps. When the two traps are driven at the same radio frequency, the strength of confinement can be reduced near the junction between the two traps, depending upon the relative phase of the RF voltage used to operate each of the two traps, and can cause loss of ions during each transit between the traps and thereby cause loss of the 40.507-GHz ion-clock resonance signal. The essence of the modification is to drive the two traps at different frequencies typically between 1.5 and 2 MHz for the quadrupole trap and a frequency a few hundred kHz higher for the 16- pole trap. A frequency difference of a few hundred kHz ensures that the ion motion caused by the trapping electric fields is small relative to the diameter of the traps. Unlike in the case in which both traps are driven at the same frequency, the trapping electric fields near the junction are not zero at all times; instead, the regions of low electric field near the junction open and close at the difference frequency. An additional benefit of making the 16-pole trap operate at higher frequency is that the strength or depth of the multipole trap can be increased independent of the quadrupole ion trap.

Prestage, John↗

Ghost imaging second harmonic generation microscopy

Second harmonic generation (SHG) microscopy is useful for visualizing interfaces and sub-structures within a wide range of materials due to the propensity for SHG to occur in non-centrosymmetric environments. However, since SHG is a nonlinear process generally necessitating small focal sizes for higher peak powers, a raster scanning approach is usually needed to build an SHG image over a significant sample size. While raster scanning is effective, there is a cost in terms of the time needed to acquire the image and, also, some materials cannot withstand the higher optical intensities within the small focal volume. As such, we describe a SHG microscopy approach based on ghost imaging (GI), which enables imaging data to be collected in parallel rather than sequentially as in raster scanning techniques. We experimentally demonstrate the approach and combine GI-SHG with compressive sensing to make further substantial gains in reducing the amount of sampling required for image reconstruction. Furthermore, GI-SHG is shown to have significant advantages for imaging in highly scattering environments, partly because GI is a background-free approach requiring spatial correlations between photons that travel two paths, with one path entirely devoid of sample interaction. This basic property of GI means that only the photons that travel unimpeded through the sample preserve the spatial correlations needed to reconstruct the image, while more scattered photons do not contribute to the overall GI signal. Finally, we compare the image quality and sampling properties of three different reconstruction algorithms used for compressive sensing.

47 OTHER INSTRUMENTATION↗

VARIABILITY AT THE EDGE: OPTICAL NEAR/IR RAPID-CADENCE MONITORING OF NEWLY OUTBURSTING FU ORIONIS OBJECT HBC 722

We present the detection of day-timescale periodic variability in the r-band lightcurve of newly outbursting FU Orionis-type object HBC 722, taken from >42 nights of observation with the CQUEAN instrument on the McDonald Observatory 2.1 m telescope. The optical/near-IR lightcurve of HBC 722 shows a complex array of periodic variability, clustering around 5.8-day (0.044 mag amplitude) and 1.28-day (0.016 mag amplitude) periods, after removal of overall baseline variation. We attribute the unusual number of comparable strength signals to a phenomenon related to the temporary increase in accretion rate associated with FUors. We consider semi-random 'flickering', magnetic braking/field compression and rotational asymmetries in the disk instability region as potential sources of variability. Assuming that the 5.8-day period is due to stellar rotation and the 1.28-day period is indicative of Keplerian rotation at the inner radius of the accretion disk (at 2 R {sub *}), we derive a B-field strength of 2.2-2.7 kG, slightly larger than typical T Tauri stars. If instead the 5.8-day signal is from a disk asymmetry, the instability region has an outer radius of 5.4 R {sub *}, consistent with models of FUor disks. Further exploration of the time domain in this complicated source and related objects will be key to understanding accretion processes.

79 ASTRONOMY AND ASTROPHYSICS↗

The HYDICE instrument design and its application to planetary instruments

The Hyperspectral Digital Imagery Collection Experiment (HYDICE) instrument represents a significant advance in the state of the art in hyperspectral sensors. It combines a higher signal-to-noise ratio (SNR) and significantly better spatial and spectral resolution and radio metric accuracy than systems flying on aircraft today. The need for 'clean' data, i.e., data free of sampling artifacts and excessive spatial or spectral noise, is a key driver behind the difficult combination of performance requirements laid out for HYDICE. Most of these involve the sensor optics and detector. This paper presents an optimized approach to those requirements, one that comprises push broom scanning, a single, mechanically cooled focal plane, a double-pass prism spectrometer, and an easily fabricated yet wide-field telescope. Central to the approach is a detector array that covers the entire spectrum from 0.4 to 2.5 microns. Among the major benefits conferred by such a design are optical and mechanical simplicity, low polarization sensitivity, and coverage of the entire spectrum without suffering the spectral gaps caused by beam splitters. The overall system minimizes interfaces to the C-141 aircraft on which it will be flown, can be calibrated on the ground and in flight to accuracies better than those required, and is designed for simple, push-button operation. Only unprocessed data are recorded during flight. A ground data processing station provides quick-look, calibration correction, and archiving capabilities, with a throughput better than the requirements. Overall performance of the system is expected to provide the solid database required to evaluate the potential of hyperspectral imagery in a wide variety of applications. HYDICE can be regarded as a test bed for future planetary instruments. The ability to spectrally image a wide field of view over multiple spectral octaves offers obvious advantages and is expected to maximize science return for the required cost and weight.

Basedow, R.↗

Signals of Warped Extra Dimensions at the LHC

We discuss the signatures of the spin-2 graviton excitations predicted by the Randall-Sundrum model with one warped extra dimension, in dilepton and diphoton production at LHC. By using a specific angular analysis, we assess the ranges in mass and coupling constant where such gravitons can be discriminated against competitor spin-1 and spin-0 objects, that potentially could manifest themselves in these processes with the same mass and rate of events. Depending on the value of the coupling constant to quarks and leptons, the numerical results indicate graviton identification mass ranges up to 1.1-2.4 TeV and 1.6-3.2 TeV for LHC nominal energy of 14 TeV and time-integrated luminosity of 10 and 100fb{sup -1}, respectively.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Effect of number of stack on the thermal escape and non-radiative and radiative recombinations of photoexcited carriers in strain-balanced InGaAs/GaAsP multiple quantum-well-inserted solar cells

Three non-destructive methodologies, namely, surface photovoltage (SPV), photoluminescence, and piezoelectric photothermal (PPT) spectroscopies, were adopted to detect the thermal carrier escape from quantum well (QW) and radiative and non-radiative carrier recombinations, respectively, in strain-balanced InGaAs/GaAsP multiple-quantum-well (MQW)-inserted GaAs p-i-n solar cell structure samples. Although the optical absorbance signal intensity was proportional to the number of QW stack, the signal intensities of the SPV and PPT methods decreased at high number of stack. To explain the temperature dependency of these signal intensities, we proposed a model that considers the three carrier dynamics: the thermal escape from the QW, and the non-radiative and radiative carrier recombinations within the QW. From the fitting procedures, it was estimated that the activation energies of the thermal escape ΔE{sub barr} and non-radiative recombination ΔE{sub NR} were 68 and 29 meV, respectively, for a 30-stacked MQW sample. The estimated ΔE{sub barr} value agreed well with the difference between the first electron subband and the top of the potential barrier in the conduction band. We found that ΔE{sub barr} remained constant at approximately 70 meV even with increasing QW stack number. However, the ΔE{sub NR} value monotonically increased with the increase in the number of stack. Since this implies that non-radiative recombination becomes improbable as the number of stack increases, we found that the radiative recombination probability for electrons photoexcited within the QW increased at a large number of QW stack. Additional processes of escaping and recapturing of carriers at neighboring QW were discussed. As a result, the combination of the three non-destructive methodologies provided us new insights for optimizing the MQW components to further improve the cell performance.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Study of fluorocarbon plasma in 60 and 100 MHz capacitively coupled discharges using mass spectrometry

The signals of positive ions and radicals formed in the fluorocarbon plasma of the capacitively coupled plasma reactor were measured using a quadrupole mass spectrometry and optical emission actinometry. The plasma was produced at 60 and 100 MHz frequencies for the same reactor configuration and gas mixtures. Experiments were performed at 25 mTorr with a SiO{sub 2} wafer on the grounded electrode. Mass spectra of ions were measured in C{sub 4}F{sub 8}/O{sub 2}/Ar and C{sub 4}F{sub 6}/O{sub 2}/Ar gas mixtures at 500-1500 W generator powers. For 60 and 100 MHz discharges production of fluorocarbon ions and radicals is discussed. It was found that the production of heavy species increases with frequency. The high mass signals such as C{sub 3}F{sub 3}{sup +}, C{sub 2}F{sub 4}{sup +}, C{sub 2}F{sub 5}{sup +}, C{sub 3}F{sub 5}{sup +}, C{sub 4}F{sub 7}{sup +} decrease when CHF{sub 3} is added to the gas mixture. However, the signals of CF{sub x}{sup +} (x=1,2,3) do not change significantly. These results are compared to the results of polymer film deposition on the wafer. It was suggested to control the polymerization film formation by adding small amount of CHF{sub 3} to the process mixture.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Acoustic signals generated by laser-irradiated metal nanoparticles

We present a physical model that explains several sequential stages of the conversion of optical to acoustical energy when irradiating diluted suspensions of metal nanoparticles with laser pulses. Optical absorption and scattering of a single particle driven by plasmon resonance interactions in an aqueous medium are considered. Thermal effects produced by laser-irradiated nanoparticles, dynamics of vapor bubble formation, and acoustic signals from expanding bubbles formed around heated nanoparticles are calculated. Stochastic features of the pressure magnitude emitted as a result of low-fluence irradiation of suspensions are also discussed. The probabilistic distribution of pressure magnitude from individual bubbles was found to obey Zipf's law for low concentrations of nanoparticles, while increasing their concentration brings the pressure magnitude distribution into conformance with the Gaussian law.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The application of spaceborne GPS to atmospheric limb sounding and global change monitoring

This monograph is intended for readers with minimal background in radio science who seek a relatively comprehensive treatment of the mission and technical aspects of an Earth-orbiting radio occultation satellite. Part 1 (chapters 1-6) describes mission concepts and programmatic information; Part 2 (chapters 7-12) deals with the theoretical aspects of analyzing and interpreting radio occultation measurements. In this mission concept the navigation signals from a Global Positioning System (GPS) satellite that is being occulted by the Earth's limb are observed by a GPS flight receiver on board a low Earth orbiter (LEO) satellite. This technique can be used to recover profiles of the Earth's atmospheric refractivity, pressure, and temperature using small, dedicated, and relatively low-cost space systems. Chapter 2 summarizes the basic space system concepts of the limb-sounding technique and describes a low-cost strawman demonstration mission. Chapter 3 discusses some of the scientific benefits of using radio occultation on a suite of small satellites. Chapter 4 provides a more detailed discussion of several system elements in a radio occultation mission, including the launch system for small payloads, the LEO microsat, the GPS constellation, the GPS flight receiver payload, the mission operations ground control and data receiving system, the ground-based GPS global tracking network for precision orbit determination, and the central data processing and archive system. Chapter 5 addresses the various technology readiness questions that invariably arise. Chapter 6 discusses the overall costs of a demonstration mission such as GPS/MET (meteorological) proposed by the University Navstar Consortium (UNAVCO). Chapter 7 describes a geometrical optics approach to coplanar atmospheric occultation. Chapter 8 addresses major questions regarding accuracy of the occultation techniques. Chapter 9 describes some simulations that have been performed to evaluate the sensitivity of the recovered profiles of atmospheric parameters to different error sources, such as departure from spherical symmetry, water vapor, etc. Chapter 10 discusses horizontal and vertical resolution associated with limb sounders in general. Chapter 11 treats selected Fresnel diffraction techniques that can be used in radio occultation measurements to sharpen resolution. Chapter 12 provides brief discussions on selected special topics, such as strategies for handling interference and multipath processes that may arise for rays traveling in the lower troposphere.

Melbourne, W. G.↗

Nonresonant coherent amplitude transfer in attosecond four-wave-mixing spectroscopy

Attosecond four-wave mixing (FWM) spectroscopy using an extreme ultraviolet (XUV) pulse and two noncollinear near-infrared (NIR) pulses is employed to measure Rydberg wave packet dynamics resulting from XUV excitation of a 3s electron in atomic argon into a series of autoionizing 3s –1 np Rydberg states ~29 eV. The emitted signals from individual Rydberg states exhibit oscillatory structure and persist well beyond the expected lifetimes of the emitting Rydberg states. These results reflect substantial contributions of longer-lived Rydberg states to the FWM emission signals of each individually detected state. A wave packet decomposition analysis reveals that coherent amplitude transfer occurs predominantly from photoexcited 3s –1 (n + 1) p states to the observed 3s –1 np Rydberg states. The experimental observations are reproduced by time-dependent Schrödinger equation simulations using electronic structure and transition moment calculations. Finally, the theory highlights that coherent amplitude transfer is driven nonresonantly to the 3s –1 np states by the NIR light through 3s –1 (n + 1)s and 3s –1 (n – 1)d dark states during the FWM process.

74 ATOMIC AND MOLECULAR PHYSICS↗

Spatial heterodyne spectroscopy for fast local magnetic field measurements of magnetized fusion plasmas

A novel spectroscopy diagnostic for measuring internal magnetic fields in high temperature magnetized plasmas has been developed. It involves spectrally resolving the Balmer- α (656 nm) neutral beam radiation split by the motional Stark effect with a spatial heterodyne spectrometer (SHS). The unique combination of high optical throughput (3.7 mm 2 sr) and spectral resolution (δλ ~ 0.1 nm) allows these measurements to be made with time resolution $\ll$1 ms. The high throughput is effectively utilized by incorporating a novel geometric Doppler broadening compensation technique in the spectrometer. The technique significantly reduces the spectral resolution penalty inherent to using large area, high-throughput optics while still collecting the large photon flux provided by such optics. In this work, fluxes of order 10 10 s –1 support the measurement of deviations of <5 mT (Δ λ Stark ~ 10 –4 nm) in the local magnetic field with 50 µs time resolution. Example high time resolution measurements of the pedestal magnetic field throughout the ELM cycle of a DIII-D tokamak plasma are presented. Local magnetic field measurements give access to the dynamics of the edge current density, which is essential to understanding stability limits, edge localized mode generation and suppression, and predicting performance of H-mode tokamaks.

47 OTHER INSTRUMENTATION↗

Mini Micropulse Lidar measurements in vertical and scanning modes

The Atmospheric Radiation Measurement (ARM) program operates ten Sigma Space (currently Droplet Measurement Technologies/DMT) micropulse lidar systems (MPL-4B-IDS/POL-FS series), which detect the backscattered light in two orthogonal linear polarization channels allowing to distinguish between spherical (e.g. water) and non-spherical (e.g. ice) scattering particles. The ARM MPLs have been providing valuable measurements to the aerosol and cloud research community for well over a decade. DMT&rsquo;s Mini-Micropulse lidar (MiniMPL) is a compact version of the standard MPL. It reduces the power-aperture product to minimize cost, size, weight, power requirements and has all the electronics integrated with optics in a single box. Although as a result, it has a lower detection range than the MPL, limiting the measurements to the troposphere, its performance is promised to match that of the standard MPL within the troposphere. The MiniMPL weighs 13 kg, and the complete system, consisting of an optical transceiver and a laptop running the data acquisition and post-processing software, fits in a storm case, allowing its transport on domestic or international flights. This can be especially valuable for short field campaigns or Intensive Operational Periods, where time is of the essence when replacing a faulty instrument. In addition, the scanning polarization lidar capability (MiniMPL-SCAN option) could be of great interest for satisfying ARM measurement needs for certain research topics related to clouds and precipitation. To evaluate its full potential in comparison with co-located remote sensing instruments including the ARM MPL-4B-IDS/POL-FS at SGP, a miniMPL was hosted at the ARM Southern Great Plains (SGP) mega-site in 2020 for approximately 3 months. During this time the miniMPL was tested in both vertical sampling and scanning modes.

54 ENVIRONMENTAL SCIENCES↗

X-Ray Spectroscopy of Optically Bright Planets using the Chandra Observatory

Since its launch in July 1999, Chandra's Advanced CCD Imaging Spectrometer (ACIS) has observed several planets (Venus, Mars, Jupiter and Saturn) and 6 comets. At 0.5 arc-second spatial resolution, ACIS detects individual x-ray photons with good quantum efficiency (25% at 0.6 KeV) and energy resolution (20% FWHM at 0.6 KeV). However, the ACIS CCDs are also sensitive to optical and near-infrared light, which is absorbed by optical blocking filters (OBFs) that eliminate optical contamination from all but the brightest extended sources, e.g., planets. .Jupiter at opposition subseconds approx.45 arc-seconds (90 CCD pixels.) Since Chandra is incapable of tracking a moving target, the planet takes 10 - 20 kiloseconds to move across the most sensitive ACIS CCD, after which the observatory must be re-pointed. Meanwhile, the OBF covering that CCD adds an opt,ical signal equivalent to approx.110 eV to each pixel that lies within thc outline of the Jovian disk. This has three consequences: (1) the observatory must be pointed away from Jupiter while CCD bias maps are constructed; (2) most x-rays from within the optical image will be misidentified as charged-particle background and ignored; and (3) those x-rays that are reported will bc assigned anomalously high energies. The same also applies to thc other planets, but is less serious since they are either dimmer at optical wavelengths, or they show less apparent motion across the sky, permitting reduced CCD exposure times: the optical contamination from Saturn acids approx.15 eV per pixel, and from Mars and Venus approx.31 eV. After analyzing a series of short .Jupiter observations in December 2000, ACIS parameters were optimized for the February 2003 opposition. CCD bias maps were constructed while Chandra pointed away from Jupiter, and the subsequent observations employed on-board software to ignore any pixel that contained less charge than that expected from optical leakage. In addition, ACIS was commanded to report 5 x 5 arrays of pixel values surrounding each x-ray event, and the outlying values were employed during ground processing to correct for the optical contamination.

Ford, P. G.↗

Efficient Signal Processing in BOTDA: Utilizing PCA and PCA-Based Neural Networks for Temperature Monitoring

This work presents a comparative analysis of the various signal processing techniques used in the Brillouin gain spectrum (BGS) peak estimation. Traditional fitting methods such as Lorentzian curve fitting (LCF) are slow and less effective in noisy data. PCA-based methods were tested on the experimental data: A Euclidian distance-based approach, and a probabilistic deep neural network (PDNN) based approach, both using 5 principal components to represent a single BGS. Both methods significantly reduce computational time with respect to LCF, whereas PDNN offers uncertainty insights along with the parameter value. Measuring a range of temperatures, analyzing accuracy, and speed, it can be concluded that PCA trained PDNN outperforms other methods, and appears to be helpful in scenario where large datasets are generated.

Brillouin optical time domain analysis↗

miniTimeCube as a neutron scatter camera

We present Monte Carlo (MC) simulation results from a study of a compact plastic-scintillator detector suitable for imaging fast neutrons in the 1 – 10 MeV energy range: the miniTimeCube (mTC). Originally designed for antineutrino detection, the mTC consists of 24 MultiChannel Plate (MCP) photodetectors surrounding a 13 cm cube of boron-doped plastic scintillator. Our simulation results show that waveform digitization of 1536 optically sensitive channels surrounding the scintillator should allow for spatiotemporal determination of individual neutron-proton scatters in the detector volume to ~ 100 picoseconds and ~5 mm. A Bayesian estimation framework is presented for multiple-scatter reconstruction, and is used to estimate the incoming direction and energy of simulated individual neutrons. Finally, we show how populations of reconstructed neutrons can be used to estimate the direction and energy spectrum of nearby simulated neutron sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An investigation to determine the producibility of a 3-D braider and bias direction weaving loom

The development of prototype machines for the production of generalized braid patterns is described. Mechanical operating principles and control strategies are presented for two prototype machines which were fabricated and evaluated. Both machines represent advances over current techniques for forming composite material preforms by enabling near ideal control of fiber orientation. Furthermore, they overcome both the lack of general control of produced fiber architectures and the complexity of other weaving processes that were produced for the same purpose. One prototype, the modified Farley braider, consists of an array of turntables which can be rotated 90 degrees and returned; hence, they can form tracks in the x and y axis. Yarn ends are transported about the surface formed by the turntables using motorized tractors. These tractors are controlled using an optical link with a control circuit and host computer. The tractors are powered through electrical contact with the turntables. The necessary relative motions are produced by a series of linear tractor moves combined with a sequence of turntable rotations. The movement of the tractors about the surface causes the yarns to produce the desired braiding pattern. The second device, the shuttle plate braider, consists of a braiding surface formed by an array of square elements, each separated from its neighbor by a gap. Beneath this surface lies a shuttle plate, which reciprocates first in one axis and then in the other. As this movement takes place, yarn carrying shuttles engage and disengage the plate by means of solenoid activated pins. By selective engagement and disengagement, the shuttles can move the yarn ends in any desired pattern, forming the desired braid. Control power, and control signals, are transmitted from the electronic interface circuit and host computer, via the braiding surface through electrical contact with the shuttles. Motive power is proved to the shuttles by motion of the shuttle plate, which is passively driven using pneumatic rams. Each shuttle is a simple device that uses only a solenoid to engage the plate and is a simple device that uses only a solenoid to engage the plate and is independently controllable. When compared with each other, the modified Farley braider has the advantage of speed, and the shuttle plate braider the advantage of mechanical control and simplicity.

Huey, Cecil O., Jr.↗

Thermodynamic measurements in a high pressure hydrogen-oxygen flame using Raman scattering from a broadband excimer laser

Raman scattering is an inelastic molecular scattering process in which incident radiation is reemitted at a fixed change in frequency. Raman spectroscopy can be used to measure the number density and temperature of the irradiated species. The strength of the Raman signal is inversely proportional to the wavelength raised to the fourth power. Consequently, high signal to noise ratios are obtained by using ultraviolet (UV) excitation sources. Using UV sources for Raman Spectroscopy in flames is complicated by the fact that some of the primary constituents in hydrogen-oxygen combustion absorb and reemit light in the UV and these fluorescence processes interfere with the Raman signals. This problem has been handled in atmospheric pressure flames in some instances by using a narrowband tunable excimer laser as a source. This allows for detuning from absorption transitions and the elimination of interfering fluorescence signals at the Raman wavelengths. This approach works well in the atmospheric pressure flame; however, it has two important disadvantages. First, injection-locked narrowband tunable excimer lasers are very expensive. More importantly, however, is the fact that at the high pressures characteristic of rocket engine combustion chambers, the absorption transitions are broadened making it difficult to tune to a spectral location at which substantial absorption would not occur. The approach taken in this work is to separate the Raman signal from the fluorescence background by taking advantage of the fact that Raman signal has nonisotropic polarization characteristics while the fluorescence signals are unpolarized. Specifically, for scattering at right angles to the excitation beam path, the Raman signal is completely polarized. The Raman signal is separated from the fluorescence background by collecting both horizontally and vertically polarized signals separately. One of the polarizations has both the Raman signal and the fluorescence background while the other has only the fluorescence signal. The Raman scatter is the difference between the signals. By choosing an appropriate optical setup, both signals can be obtained simultaneously with the same monochromator; hence, time resolved measurements are possible using this approach.

Hartfield, Roy, Jr.↗