Search NASA⌕ Search

SEARCH · Search NASA

Results for “Paper”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

Shielding Design of Gantry 3 - Paper 104

The proton therapy complex at PSI will be extended with a third irradiation facility, Gantry 3. This new Gantry is being built in the south-west area of the experimental hall of the High Intensity Proton Accelerator (HIPA) complex at PSI. Originally, it was planned to restrict the operation of Gantry 3 to 180 deg. by hardware means, but due to new considerations, the Gantry will be able to be moved in the full 360 deg. field. This change requires the redesign and reinforcement of the too weak shielding in the north and east directions. Additionally, the isocenter has been fixed, thus allowing for the exact calculation of distances, angles and effective shielding thicknesses in order to determine the dose rates more accurately. For these calculations a fast and simple semi-empirical analytical formula and the more time consuming, but also more sophisticated best estimate code MCNPX 2.7.0 have been used. The two methods used for the calculations of the dose rates are in good agreement. Generally, the analytical method provides the results instantaneously, but predicts higher dose rate values of a factor 2-3 larger than the Monte-Carlo particle transport code MCNPX. Thus, MCNPX should be used to verify the final design of the shielding, including additional details in the simulation model (e.g. ventilation shafts) which have weakening effect on the shielding. Such influences are hard to quantify analytically. The analytical method fails when the geometry becomes complex, i.e. when it is difficult to determine the effective length of the shielding; in the case of position 10 the shielding effect of the inner wall is difficult to quantify. Due to the change of the specification of the Gantry, the shielding was reinforced at the north and east sides, and the HC-layer was extended in front of the control room. The dose rates are acceptable with the new shielding layout. A detailed dose rate mapping is planned in the commissioning phase of Gantry 3 to verify the simulation results and to identify any remaining weak spots of the shielding. (authors)

43 PARTICLE ACCELERATORS↗

Calculated and Measured Dose Distributions in an Anthropomorphic RANDO Phantom - Paper 105

Patient-specific quality assurance (QA) is a major component of the Intensity Modulated Radiation Therapy (IMRT) clinical process. The objective of this often time-intensive measurement process is to verify that the prescribed dose is accurately delivered to the target volume while sparing surrounding healthy tissue. The IMRT dose distributions can be measured using a wide variety of techniques and measurement devices including film (radiographic and radiochromic), ion chamber arrays, diode arrays, and Electronic Portal Imaging Devices (EPIDs). Of all the available modalities, film is one of the most versatile and most frequently utilized measurement systems. In rotation delivery techniques (such as volume modulated arc therapy and helical tomotherapy), composite dose distributions are obtained by irradiating a test phantom containing dosimeter(s). When film is utilized as the dosimeter, it can be placed in coronal, sagittal, or transverse planes inside the phantom. Because the film is irradiated using the rotational delivery sequence used to treat the patient, the dose given to specific anatomical structures (such as the parotids, spinal cord, bladder, rectum etc...) can be evaluated. Thomas et al (Med Phys 32: 3793-3800) recently reported the results of IMRT verifications for ten patients planned and treated with helical tomotherapy. This study reported that nearly 92% of the film pixels within the analyzed region of interest were within a gamma criterion of 2 mm and 2%. Like most tomotherapy users, Thomas et al used a test phantom made of homogeneous water equivalent material. Heterogeneous phantoms that simulate the different tissue densities in the human body do exist, but are infrequently used for patient-specific IMRT QA. The potential advantage of using heterogeneous phantoms is that the measured dose distributions will more adequately reflect the clinical dose distributions in the patients. The use of homogenous phantoms during IMRT quality assurance can potentially mask errors that arise from limitations in the treatment planning system's modeling of density corrections. The purpose of this study was to evaluate the dosimetric accuracy of a helical tomotherapy system using an anthropomorphic RANDO phantom (The Phantom Laboratory, Salem, NY) for patient-specific QA. The results of this study will allow a benchmark to be established for dosimetric accuracy in heterogeneous materials. Performing patient-specific QA is an integral part of the IMRT patient treatment process. Test phantoms are typically homogeneous, and do test the treatment planning systems ability to account for heterogeneity corrections. In this study, an anthropomorphic RANDO phantom was used to evaluate the doses calculated by a helical tomotherapy system. The dosimetric agreement between calculated and measured was worse than published results in homogenous phantoms, especially for target volumes located in the lung. Further investigation will be needed to determine if these errors are due to film response at heterogeneous tissue interfaces or from actual dose calculation errors. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Waste Management Analyses for Spent Structures at SNS - Paper 106

The Spallation Neutron Source (SNS) in Oak Ridge, Tennessee, is an accelerator driven neutron scattering facility for materials research. Presently, the SNS operates at 1.2 megawatt (MW) proton beam power incident on a mercury target with a proton beam energy of 1 GeV and 60 Hz repetition rate. The SNS consists of an accelerator facility, target facility, and a world-class suite of neutron scattering instruments supporting material, life-science and fundamental physics research. According to the SNS operations plan, some components are replaced when they reach their end-of-life due to radiation induced material damage or burn-up, or because of mechanical failure. During operation, these components, especially those in proximity to the target, are exposed to a radiation environment and build up significant activity during their service lifetime. All these components must be safely removed, placed in a container/package for storage, and ultimately transported offsite for disposal. An accurate estimate of the radionuclide inventory is performed assuming realistic irradiation history and decay time in order to classify a spent component. On the basis of a calculated radionuclide inventory, the spent component is classified, and an appropriate cask/package for transport and storage is suggested. After the choice for the container is made, radiation transport calculations are performed for the facility component placed inside the container, to ensure that the container is compliant with waste management regulations. When necessary, additional shielding is added. For each spent component before it goes out of the SNS site, supporting documentation is produced with a radionuclide inventory prediction, dose rate analyses and, if required, additional shielding. A dose rate analyses for the exposure prediction of personnel during components change out are performed as well. Most of the effort is concentrated on the target facility components such as target, proton beam window (PBW) and core vessel insert (CVI) plugs because of severe radiation conditions. Additionally, analyses are performed for the accelerator facility components, which are removed from the facility. Activation analyses and residual dose rates analyses are performed to support safe handling of SNS spent components at the SNS site and during transport to the waste disposal site. On the basis of the calculated radionuclide inventories, spent components characterized and classified with respect to waste management guidelines, and activity-based determinations are made regarding appropriate packaging for transport. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Investigation of Radiation Cross-Talk Effects on Biological Dose Rates in Maintenance Areas Inside the ITER Tokamak - Paper 107

The intense plasma neutron source of ITER requires careful consideration of radiation safety during the design of the machine, its operation plan and licensing process. One important issue is that of occupational radiation exposure (ORE) during in-situ maintenance activities inside the cryostat, and particularly in the port inter-space area (PI) where up keeping of port systems should take place (diagnostics, tritium breeding test modules, heating antennas). ITER ports and port plugs (PP) become activated by neutron irradiation during plasma operation; from the subsequent decay and gamma emission of irradiated materials, the so-called shutdown dose rate field (SDR) appears. A project requirement of 100 uSv/h after 12 days exists for the SDR in the PI in order to limit exposure during maintenance and meet ORE regulatory limits. This requirement is particularly challenging for equatorial ports (EP) due to, among others, background neutron radiation and activation from/by neighbouring components (a.k.a. 'cross-talk'), and particularly the lower ports (LP). For a particular port inter-space, the SDR field is a combination of: (i) the gamma dose due to the activation of components local to the PI, typically referring to the PI itself plus the port plug, port duct and bellows, vessel extension and blankets in its vicinity; (ii) the gamma dose due to activation of components far away from the PI, a.k.a. the cross-talk, which typically refers to other ports, cryostat and rest of the vacuum vessel and blankets. The situation is complicated to some extent by the fact that both these components can arise from a combination of irradiation by local neutrons, i.e. those permeating through the vicinity of the port itself, and by cross-talk neutrons, i.e. those permeating via other paths. In simple terms, the so-called 'neutron cross-talk' refers to neutron leakage through other ports and components producing activation, decay gammas and dose locally in the PI of interest, whereas the 'gamma cross-talk' refers to activation and decay gammas in other ports producing dose in the PI from far away. The study reported here focuses on the evaluation of the effect of radiation cross-talk from a torus cryopump (TCP) LP located directly underneath a generic diagnostics equatorial port plug (DEPP) in the equatorial port itself. This is considered the worst case scenario, as the TCP-LP has a large aperture and has to be mostly empty in order to meet TCP pumping requirements. For the reference case and R1, the neutron cross-talk from the LP activating the EP is responsible for 109 uSv/h. In addition, a gamma cross-talk of 51 uSv/h from LP activation has been found. The total cross-talk contribution is therefore responsible for 160 uSv/h of SDR at EP PI. The local SDR contribution, i.e. that from activation of the EP with 'local-only' neutrons, is 166 uSv/h. The total SDR at R1 is 360 uSv/h, including some minor contributions from the UP, lateral EPs, cryostat and bio-shield. The total SDR at R2 is 349 uSv/hr, with a cross-talk contribution of 203 uSv/h. In R2 the gamma cross-talk is more intense, as it is closer to the highly activated TCPH. These results illustrate how the SDR field produced by radiation cross-talk through a TCP-LP is comparable in magnitude with that produced by neutron leakage and activation local to the EP. Shielding options are currently under consideration. Local gamma shielding at the EP PI is found to be effective in reducing gamma cross-talk from the LP and TCPH, and also in reducing the local contribution from the port duct and bellows. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Study of Plastic Scintillator Properties for Radioactive Sources Dosimetry - Paper 108

Plastic scintillator is a simple material which has the density close to that of human soft tissue (1.06 g/cm{sup 3}). Its energy response is close to that of human soft tissue and it is relatively energy independent. This prospect provide a desired characteristics in measuring dose by plastic scintillator either for radiation monitoring or personal dosimeter. Generally the energy calibration of organic scintillator will be done by using gamma ray sources. The positions of Compton edge in pulse height spectra, which have known energy values will be identified. However the Compton edge normally is very broad and difficult to determine the point corresponding to that particular Compton electron energies. Many researchers used several fitting functions and Monte Carlo simulations to determine the position of Compton edge. For example, Proctor and Wellman (2012) used a straight line fit to the linear part of Compton edge and extrapolated to zero count. While L. Swiderski et al. used a method based on a back-scattered coincidence measurement to measure in a wide energy range the position of Compton edge in organic scintillators. For a simple and quick approach of calibration, we used a Gauss-error function to fit the Compton edge region of interest by assumed that the location of maximum energy of Compton electrons is half-height of the Compton maximum (CM). The reasons is because the CM position could be determined easily from the spectra throughout wide energy range. Interpreting gamma dose rates from accumulated plastic scintillation detector spectra is often a complex task because the probability of a full energy deposition event in the detector is often negligible. Despite no full energy peaks in plastic scintillator spectra, several attempts have been made by the other researchers to obtain the dose from the energy distribution spectra of gamma radiation. For example, Proctor and Wellman used the modified spectrum dose index (SDI) to calculate the exposure rates by multiplying the energy corresponding to its channel and all products are summed before multiply by a calibration constant to yield an exposure rate. While Lobdell and Hertel calculated dose using a response matrix based on spectral unfolding technique. From these points of view, we have made an attempt to correlate the counts obtained in scintillator with absorbed dose or ambient dose equivalent. We aimed to calibrate the plastic scintillator energy deposition for dose, by correlate the counts obtained with a particular value of dose. By designed the scintillator to measure at 1 cm tissue depth might be helpful to be used as radiation monitoring or personal dosimeter since the energy response of plastic scintillator is relatively energy independent compared to that of inorganic scintillators. The energy calibration proposed from simple fitting approach had been verified with calculated spectra. This might be considered as a practical approach for technician or radiation workers with sufficient accuracy. The linear behavior of counts per absorbed dose give promising to calibrate scintillator energy deposition to read dose (equivalent dose or absorbed dose) for photons. Thus the scintillator could provide both the energy and dose response simultaneously, which may important in some radiation field of measurements. Currently the scintillator is able to give dose rate value for gamma sources of Cs-137 and Mn-54. The number of counts per unit absorbed dose would likely to vary somewhat with photon energy, although the plastic scintillator should have a tissue dose response that is relatively energy independent. Further analysis will be done on conversion factor parameters so that it could be used in such situations where the radiation field is complex or unknown. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Production of Neutrons by Transport of a GCR Solar Minimum Spectrum through Shielding - Paper 112

The requirements for radiation instrumentation in space can be quite different from those used for terrestrial applications. For example, most neutron instruments used for dosimetry applications used on Earth are sensitive to fission neutron energies and lower, and as such are only useful for neutron energies below 20 to 50 MeV. In space, neutrons are created by galactic cosmic ray (GCR) and solar energetic particle (SEP) interactions in materials, and as such can attain TeV energies and higher. The purpose of this study is to determine the significance of the flux of high energy neutrons in space, and to what degree neutron instruments in space must be sensitive to those high energy neutrons. PHITS transport code calculations of secondary neutron production through various thicknesses of aluminum and water shielding indicate that a significant fraction of the neutron flux and neutron effective dose comes from neutrons above 20 MeV. Measurement of high energy neutrons in space is a difficult task, especially given that the measurement will take place in a mixed radiation field where any signal from an incident neutron must be separated from signals generated by gamma rays, electrons and charged hadrons. Conventional neutron detection methodology dictates that the ability to detect high energy neutrons with a sufficient efficiency depends on the mass of the neutron detector, to first order. The more mass a neutron detector has, the higher the probability of detecting a high energy neutron. However, adding mass comes at a premium in space, often adding costs that prohibit the implementation of a new design with more mass. Thus, to accurately measure the effective dose to humans in space from secondary neutron irradiation, it requires novel methodologies that can stretch the limits of low-mass neutrons detectors, such as developing versatile response functions that are well characterized and can function over a wide range of very different neutron energy spectra. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiation Transport Calculations in Support of FRIB Target Building Local Shield Design - Paper 113

Construction of the Facility for Rare Isotope Beams (FRIB) began in March 2014 on the campus of Michigan State University (MSU). FRIB will use a 400 kW heavy-ion driver LINAC to accelerate stable ions to energies greater than 200 MeV/u. Rare-isotope beam production will occur via interaction of the heavy-ion primary beam with a rotating carbon production target at the beginning of the fragmentation pre-separator located in the target building. An integral component of the design process involves the quantification of dose equivalents received by both facility personnel and the general public that can be expected once the facility is operational. The MSU ALARA goal for radiation to the general public from FRIB is <10 mrem/y (from all sources). (authors)

43 PARTICLE ACCELERATORS↗

A statistical approach for detection of anatomical change - Paper 115

The purpose of this study was to develop a novel statistics-based method for automated detection of anatomical changes using cone-beam CT (CBCT) images of head and neck (H and N) patients. Vendor supplied CBCT software provides the user with the basic tools that allow for the visual assessment of the co-registration of the reference CT data and daily CBCT images. Currently there is no commercially available CBCT software that is capable of detecting anatomical changes and giving the clinician an early alert for the treatment plan adaptation. An algorithm was developed that can detect statistically significant changes at a given confidence level for H and N patients. This tool provides a reliable and automated early warning system that enables a 'just-in-time' adaptation of the treatment plan. A method was developed for automated detection of anatomical changes in H and N patients under radiation therapy treatment. The method utilized imaging CT data along with daily CBCT images to quantitatively compare the patient anatomy against the reference CT imaging data. The comparison algorithm was developed using a statistics-based approach as opposed to threshold-based methods. The algorithm allows for reliable detection of statistically significant changes in the observed patient anatomy at a given level of confidence. The method can be employed as an integral part of the adaptive radiotherapy framework. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Shielding design for a chip irradiation test facility at SNS - Paper 119

As digital and analog circuits are more and more sophisticatedly integrated, they become increasingly susceptible to single event upsets (SEU), a cause of electronic equipment malfunction induced by cosmic rays with particular hazard potential for aviation equipment. Electronic chips sensitive to SEU have to be tested in a simulated comic ray environment to ensure their reliability. It is found that the spallation induced fast neutron spectrum is very close to the neutron spectrum of the cosmic ray. Hence, a conceptual design study of a chip irradiation test facility is funded by FAA to be carried out at SNS, the world's most powerful accelerator driven facility for neutron scattering studies on materials. Compared to existing/being construct chip irradiation test facilities at LANL and ISIS, SNS can provide wider neutron energy range and much higher fluxes. This study focuses on the aspect of shielding design for such a chip irradiation facility. A number of medium-weighted and heavy materials were examined for efficiency in reducing radiation dose rate. In general, the smaller the target monolith is while satisfying the personnel-protection-driven radiation dose rate limit at its outside, the closer to the target chips could be placed and thus less beam power it demands to satisfy a given irradiation flux requirement. Before proceed to the shielding design, the neutron source coming off the target has to be determined for selecting a best spot for chip irradiation test, in which the incoming fast neutron spectrum approximate most to the atmospheric radiation condition. It also provides a source term for the following shielding design of the irradiation enclosure. (authors)

36 MATERIALS SCIENCE↗

ADVANTG Results for a Proposed NDA System for Detecting Pin Diversion from SNF - Paper 120

This summary describes the results of applying the ADVANTG variance reduction parameter generator to accelerate continuous-energy Monte Carlo simulations of the {sup 252}Cf Interrogation with Prompt Neutron (CIPN) detection system proposed by Hu et al. for detecting the diversion of fuel elements from spent nuclear fuel (SNF) assemblies. In previous work, ADVANTG was applied to a suite of nine radiation detection, special nuclear material (SNM) movement detection, and safeguards test cases. That effort demonstrated that ADVANTG was able to provide large increases in tally figures of merit (FOMs) in nearly all of the cases without introducing bias into the Monte Carlo results. The objective of the work described here is to further evaluate ADVANTG, and also to identify gaps in capability with regard to nuclear safeguards applications, by applying the code to a challenging problem that is of a different nature from the ones previously studied. The CIPN nondestructive assay (NDA) system consists of three fission chambers embedded in a C-shaped block of polyethylene and a polyethylene-moderated {sup 252}Cf source that are placed on opposite sides of a subject SNF assembly. The idea of the detection system is to measure the difference between the background neutron count rate, due to spontaneous fission in the fuel material, and the count rate observed once the source is introduced, which is dominated by multiplication within the assembly. Based on the difference between these count rates, the fissile content of the assembly can be inferred, and this information can be used to determine if some fraction of the original fuel pins have been replaced with depleted uranium substitutes. The authors report that the system can detect the replacement of at least eight pins (3% of total mass). The ADVANTG code generates space- and energy-dependent weight-window bounds and biased source distributions based on approximate transport solutions that are efficiently generated by the Denovo 3-D discrete ordinates package. ADVANTG implements the Consistent Adjoint Driven Importance Sampling (CADIS) method for accelerating individual tallies and the Forward-Weighted CADIS (FW-CADIS) method for obtaining relatively uniform uncertainties across tallies over multiple regions and/or energy bins. The variance reduction parameters are generated in a format directly usable by standard versions of MCNP5 and MCNPX. In this work, the ADVANTG variance reduction parameter generator was applied to accelerate continuous energy MCNPX simulations of the {sup 252}Cf Interrogation with Prompt Neutron detection system for detecting the diversion of fuel elements from SNF assemblies. Variance reduction parameters generated with the existing version of ADVANTG actually slowed down tally convergence in all cases. The cause of the poor performance was found to be the lack of an induced fission source treatment in the fixed-source discrete ordinates calculations employed by ADVANTG. Because fission was treated as capture and not as a source, the importance maps generated by ADVANTG significantly underestimated the importance of thermal neutrons in and around the fuel elements. In order to obtain improved results, we developed an experimental implementation of a fission source outer iteration for the adjoint calculations. We used this prototype capability to generate new variance reduction parameters and found that the mean fission rates agreed well with those predicted by the conventional MCNPX simulations, as was expected. With these new parameters, speedup factors of 59 to 80 were obtained for the case with the background source, and factors of 17 to 24 were obtained for the cases with the interrogating source. These results demonstrate that a fission source treatment is needed to improve the effectiveness of ADVANTG in problems where the effects of induced fission are important. This includes many types of NDA problems that are relevant to safeguards applications. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurements of Space Radiation On, and On the Way To, Mars - Paper 123

The Mars Science Laboratory (MSL) spacecraft, with the Curiosity rover inside, was launched to Mars on November 25, 2011, and landed successfully on August 6, 2012. Curiosity's science payload includes ten science instruments, one of which is the Radiation Assessment Detector, RAD. The radiation environment in deep space is harsh, and is a limiting factor in planning future human missions. RAD's measurements of the radiation environments on Mars, and on a spacecraft during transit to Mars, are important precursors to a crewed mission. RAD is a compact instrument with a mass of just 1.56 kg. Despite its small size, RAD is capable of measuring the charged and neutral particles that make up the complex environments created by Galactic Cosmic Rays (GCRs) and Solar Energetic Particles (SEPs) as they traverse shielding materials. The space radiation environment consists of a continuous flux of GCRs, the intensity of which is modulated by solar activity. At or near times of solar maximum, the interplanetary magnetic field is relatively strong, and lower-energy GCRs are screened. At solar minimum, the field weakens with a corresponding increase in GCR fluxes. SEP events are sporadic, and are more likely to occur near solar maximum. Both GCRs and SEPs present potential health risks to astronauts, but the risks are of different types. The dose rate from GCRs is modest and cannot cause acute health effects. However serious late effects may arise; of particular concern are the largely unknown health effects of exposure to high-energy GCR heavy ions. There is no terrestrial analog for this exposure and this leads to large uncertainties in health risk estimates. In contrast, SEP events can be extremely intense and could potentially cause acute health effects, but they are also dominated by protons with energies below 100 MeV, which means that shielding is a practical and effective option. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experiment Design of Secondary Neutron and Charged Particles Measurement with Stopping Targets Bombarded by 100- and 230-MeV/amu Helium Ions - Paper 124

Radiotherapy using ion beams has gained momentum in radiation oncology. While the number of proton therapy facilities that have been established or are under construction is rapidly growing, interest in heavy ion (whose atomic number Z is greater than one) radiotherapy has also been revitalized in the U.S. Helium ions, with mass and charge between protons and carbon ions, have advantages of deep penetration distances with significant peak-to-entrance dose ratios and limited dose contributions from secondary neutrons and other secondary charged fragments. In consideration of these advantages, the U.S. ion beam therapy community has expressed interests in helium ions as a potential candidate for ion beam therapy, especially pediatric cases. As such, characterizing the secondary nuclear fragment field created by primary helium ion interactions along the beam delivery devices and in human tissue is important for dose assessment and patient protection. Up to now the experimental data with respect to helium ions over the therapeutic energy range, 100 - 230 MeV/amu, is scarce compared to protons and carbon ions. Kurosawa et al. measured stopping target yields and angular spectra of neutrons, protons, deuterons and tritons produced by various target materials bombarded by 100- and 180- MeV/amu helium ions; Heilbronn et al. and Cecil et al. also measured the stopping target neutron yields by 155-, 160- and 177.5-MeV/amu helium ion bombardments. We have proposed to measure angular distributions of secondary neutrons and light charged ions produced by 100- and 230-MeV/amu helium ions bombarding stopping water and iron targets. The experiment was conducted at the Heavy Ion Medical Accelerator in Chiba (HIMAC) of the National Institute of Radiological Sciences (NIRS) in Japan this June. During the literature survey for experimental setup, we found that the ratio of the ion beam range (R) to the target depth (d) varies from 0.5 - 0.98 in the stopping target measurements either for helium ions incident on various targets or carbon ions bombarding targets as tissue surrogates. The difference in the values of ratio R/d makes comparison of experimental results complicated and require accurate corrections. Hence, how the R/d ratio and cross sectional area of the targets influence the angular distributions of secondary particles is investigated by using a Monte Carlo method in this study. The influence of the depth and the cross sectional area of stopping water and iron targets on the yield and the spectra of secondary particles induced by 100- and 230-MeV/amu He ions was studied by a Monte Carlo simulation code, PHITS. The secondary charged particles and secondary neutrons who come from breakup of projectiles are highly forward-focused, while the secondary particles produced by target breakup are nearly isotropic. As the energy of {sup 4}He ions increases from 100 MeV/amu to 230 MeV/amu, the normalized intensities of charged particles decrease more gently with increasing angles, whereas the neutron angular distribution falls quickly at angles smaller than 30 deg. and starts to exceed the normalized profile of 100 MeV/amu He from 60 deg. When the target depth increases, the impact on attenuation of secondary particles is more significant for lighter target mass and higher-energy projectiles at forward angles. Also, with deeper targets, more interactions occur between the secondary particles and the target elements, which results in more target-like fragments at large and backward angles. In respect of the cross sectional area of the stopping targets, the forward angular distributions are similar to the system with smaller cross sectional area of the targets; however, no general rule was found for how the large-angle distributions are affected by the target cross sectional area. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Rigorous Two-Step Activation for Fusion Systems with PyNE - Paper 127

In fusion systems, high energy neutrons activate system components. After shutdown, the biological dose rate from photons emitted from these components must be estimated as a function of position and time for maintenance planning. High resolution results can be obtained using the mesh-based Rigorous Two-Step (R2S) method. A neutron transport simulation provides mesh-based neutron fluxes. Using these fluxes and an appropriate irradiation scenario, a nuclear inventory analysis code is used to determine the photon source density within each mesh volume element at any decay time after shutdown. The photon source density mesh is used as a source for photon transport. Photon fluxes are tallied at positions of interest and flux-to-dose rate conversion factors are used to estimate the biological dose rate. Previous work by the authors involved the creation of R2S-ACT, an open source R2S workflow, using the Direct Accelerated Geometry Monte Carlo (DAGMC) version of MCNP5 (DAG-MCNP5) for both transport steps and the ALARA nuclear inventory analysis code. Various use cases may require different combinations of transport and activation codes, and nearly all of the capabilities of R2S-ACT have broader utility. For these reasons, the individual components of R2S-ACT were reimplemented within PyNE. PyNE is a collaborative, trans-institutional, open source project consisting of Python, Cython, and C++ code pertinent to nuclear simulations and analysis. This work involved additions to the PyNE mcnp, mesh, material, alara, dagmc, and sampling modules. A lightweight r2s module was then added to connect the code from these modules. The r2s and sampling modules, together with DAG-MCNP5 and ALARA form a complete R2S workflow for obtaining shutdown dose rate results. Mesh operations, geometry discretization, physics code input/output parsing, and mesh-based source sampling capabilities have been added to PyNE generically, eliminating the need to duplicate this effort across multiple applications. The PyNE r2s module uses these capabilities to couple MCNP and ALARA to form an R2S workflow, which has been validated with the FNG shutdown dose rate benchmark. Future work will involve benchmarking the workflow using tetrahedral mesh and also non-analog sampling options. added so that they can be used interchangeably. This will allow for comparisons between results obtained by different physics codes with minimal human effort. Work will also be done to create and implement an importance sampling method for biasing neutron transport towards regions of phase space of high importance to photon dose rate tallies. This will improve the efficiency of obtaining shutdown dose rate results in large, highly-attenuating geometries. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Optimal Shielding Design For Minimum Materials Cost or Mass - Paper 128

Material costs dominate some shielding design problems. This is certainly the case for manned nuclear power space applications for which shielding is essential and the cost of launching by rocket from Earth is high. In such situations or in those where shielding volume or mass is constrained, it is important to optimize the design. Although trial and error synthesis methods may succeed, a more systematic approach is warranted. Design automation may also potentially reduce engineering costs. The objective is to automate the design of optimal radiation shielding to meet specified attenuation requirements given a menu of allowed shielding materials, their properties and their delivered costs per unit volume. The cost-optimal design is one which, at each location in the shield, chooses the menu material minimizing a particular functional of forward and adjoint angular fluxes plus material cost. Thus a Boltzmann forward and adjoint angular flux solver with additional calculations can evaluate whether a shield design is optimal or whether improvements are possible. An iterative algorithm based on approximated optimality is proposed to solve for the optimal shield design and numerical experiments with it are discussed. The future use of 3D Boltzmann solvers will allow extending results to shaped shield designs in which material is not wasted to maintain unneeded spherical symmetry. The largest cost savings of automated optimal design of shielding is expected to be for applications involving nuclear powered manned space missions where the required shielding attenuation of radiation and costs are both large. However, less exotic applications such as the shielding of radiation facilities on Earth could also benefit from optimal shielding design, and automation of the design process may reduce engineering costs. (author)

61 RADIATION PROTECTION AND DOSIMETRY↗

Efficiency Calibration of 4{pi} NaI(Tl) Gamma-ray Detectors for Plane Sources - Paper 130

4{pi} NaI(Tl) detectors are useful for low level gamma activity measurements due to the near 4{pi} solid angle that can be obtained with them. An analytical theoretical approach is presented here to calculate the absolute efficiencies for this type of detectors. The approach depends on the accurate calculation of two important factors; the path length, d, the photon traverses within the active volume of a gamma detector, and the geometrical solid angle,{Omega}, subtended by the source to the detector at the point of entrance. These two factors are theoretically derived through a straightforward analytical approach. In this work, this model is extended to an isotropic radiating point source, and a thin circular disk source. The results of the present absolute efficiency values were compared with the experimental and M.C. method works reported in the literature. The present theoretical and the experimental efficiency values are in good agreement. The present approach offers a good method to calibrate 4{pi} NaI(Tl) detectors over a large energy range without the need for standard sources, as is the case for experimental methods, nor optimization of detector parameters as for Monte Carlo simulations. Discrepancies with experimental results are reduced to lower than 4%. (author)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron production in lunar habitats - Paper 132

Lunar habitats constructed of either local materials or conventional materials used for spacecraft (such as aluminum) will provide protection for astronauts from solar energetic particles (SEP) and galactic cosmic rays (GCR). Although there are essentially no neutrons in the primary GCR and SEP fields, neutrons are produced by interactions of those fields with the lunar surface and with the lunar habitat. In a habitat, the neutrons can be divided into two categories: albedo neutrons moving generally upward through the habitat, and a generally downward flux created by interactions in the habitat walls. These two neutron fields differ in their energy spectrum, and as a result different mitigation strategies may be needed for different areas of the habitat in order to reduce the dose from neutrons. In this work, we calculate the 'upward' and 'downward' neutron fluences, using a variety of shielding materials and thicknesses. We also investigate the effect of other materials inside the habitat on the neutron fluences. The preliminary transport model calculations performed here verify the effectiveness of a hydrogenous shielding wall material, polyethylene, in reducing the neutron dose inside a simple lunar habitat geometry when compared to walls made of lunar regolith and aluminum. Separate transport model calculations were done for the albedo neutron spectrum rising up from the lunar soil and for GCR particles incident upon the habitat shielding. In the case of GCR ions incident on the habitat, shielding wall made of polyethylene reduced the neutron effective dose by a factor of three, compared to the other two shielding materials. (authors)

36 MATERIALS SCIENCE↗

FRIB Fragment Pre-separator Radiation Environment Studies - Paper 133

The Facility for Rare Isotope Beams (FRIB), a project supported by the US DOE Office of Science, is under construction at Michigan State University. The project will use projectile fragmentation and induced in-flight fission of heavy ion beams at energies of 200 MeV/u and higher, and at a beam power of 400 kW, to produce rare isotope beams for nuclear physics experiments. The production of rare isotope beams during FRIB operations creates a high radiation environment in the fragment pre-separator area where the production target is located. Adequate shielding must be placed around the beam line components to ensure personnel protection during and after the operations. Detailed radiation transport studies in the fragment pre-separator area are necessary and have been performed for proper shielding choices. We calculate neutron and photon fluxes and their energy distributions, and evaluate prompt and residual dose equivalent rates in the hot cell and prompt dose equivalent rates in the MSM gallery outside of the cell where people might be present during normal operations. We also calculate dose equivalent rates in the MSM gallery when the activated components are placed in front of the MSM lead glass window on the hot cell side. We show that the resulting dose equivalent rates are conservative even for the most neutron-rich energetic beams. These calculations guide local shielding design and support operations. (authors)

43 PARTICLE ACCELERATORS↗

Epidemiologic Studies of Radiation Workers - Paper 134

Studies of U.S. radiation workers are important because: (1) they provide information on the level of cancer and non-cancer risk following chronic exposure situations that are relevant today in medicine, occupation and environmental circumstances; (2) healthy U.S. workers are more similar to today's populations than Japanese 1945 atomic bomb survivors; (3) findings will be directly relevant to regulated worker populations; (4) organ-specific risk coefficients will be directly relevant to compensation programs; and (5) the dosimetric and epidemiologic findings can be integrated with the developing new understandings in biology for risk estimation for low doses and low dose rates. The ongoing Study of One Million U.S. Radiation Workers and Veterans is ten times larger than the study of the Japanese atomic bomb survivors of 86,000 survivors with estimated doses. The number of workers with > 100 mSv career dose is substantially greater. The large study size, broad range of doses and long follow-up indicates substantial statistical ability to quantify the risk of exposures that are received gradually over time. The study is designed to determine whether dose rate influences the future risk of cancer compared with the instantaneous exposure experienced by Japanese bomb survivors in 1945. This national effort is being coordinated by the NCRP and Vanderbilt University and includes collaborators within many government agencies (notably the DOE Low Dose Program, NRC, NASA and NCI), universities and the private sector. The study consists of 360,000 Department of Energy workers from the Manhattan Project, 150,000 nuclear utility workers from the inception of the nuclear age, 115,000 atomic veterans who participated in above ground atmospheric test at the Nevada Test Site and the Bikini Islands, 250,000 radiologists and medical workers, and 130,000 industrial radiographers. (author)

61 RADIATION PROTECTION AND DOSIMETRY↗