Search NASA⌕ Search

SEARCH · Search NASA

Results for “Performance Rating Method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

Precision Measurements of the Neutron Magnetic Form Factor to High Momentum Transfer using Durand's Method

Protons and neutrons, collectively known as nucleons, along with electrons, constitute the funda- mental building blocks of the visible universe. Understanding their internal structure is crucial for addressing key scientific questions about our origin and existence. Elastic electron-nucleon scatter- ing provides insights into the spatial distributions of charge and current within nucleons through their electromagnetic form factors. Accurate knowledge of these form factors over a broad range of Q2, the squared four-momentum transfer in the scattering process, reveals details about the nucleon’s internal structure. However, high-Q2 data of the nucleon electromagnetic form factor is scarce due to the challenges associated with such measurements. This thesis reports preliminary results from high-precision measurements of the neutron magnetic form factor (Gn M ) to unprecedented Q2 using Durand’s method, also known as the “ratio” method. Systematic errors are greatly reduced by extracting Gn M from the ratio of neutron-coincident (D(e, e'n)) to proton-coincident (D(e, e'p)) quasi-elastic electron scattering from deuteron. The scattered electrons were detected in the BigBite spectrometer, which features multiple Gas Elec- tron Multiplier (GEM) layers with large active area for high-precision tracking at very high rates. Simultaneous nucleon detection was performed by the Super BigBite spectrometer, which utilizes a dipole magnet with large solid angle acceptance at forward angles and a novel hadron calorimeter with very high and comparable detection efficiencies for both protons and neutrons. This setup could handle very high luminosity, making high-Q2 measurements feasible. Data were collected at five Q2 points: 3, 4.5, 7.4, 9.9, and 13.6 (GeV/c)2. Preliminary results are reported for all, with the lowest two Q2 points in good agreement with existing world data, while the higher points significantly extend the Q2 range in which Gn M is known accurately. The precision of the highest Q2 point is expected to remain unmatched for years to come.

Datta, Provakar↗

SU-F-R-44: Modeling Lung SBRT Tumor Response Using Bayesian Network Averaging

Purpose: The prediction of tumor control after a patient receives lung SBRT (stereotactic body radiation therapy) has proven to be challenging, due to the complex interactions between an individual’s biology and dose-volume metrics. Many of these variables have predictive power when combined, a feature that we exploit using a graph modeling approach based on Bayesian networks. This provides a probabilistic framework that allows for accurate and visually intuitive predictive modeling. The aim of this study is to uncover possible interactions between an individual patient’s characteristics and generate a robust model capable of predicting said patient’s treatment outcome. Methods: We investigated a cohort of 32 prospective patients from multiple institutions whom had received curative SBRT to the lung. The number of patients exhibiting tumor failure was observed to be 7 (event rate of 22%). The serum concentration of 5 biomarkers previously associated with NSCLC (non-small cell lung cancer) was measured pre-treatment. A total of 21 variables were analyzed including: dose-volume metrics with BED (biologically effective dose) correction and clinical variables. A Markov Chain Monte Carlo technique estimated the posterior probability distribution of the potential graphical structures. The probability of tumor failure was then estimated by averaging the top 100 graphs and applying Baye’s rule. Results: The optimal Bayesian model generated throughout this study incorporated the PTV volume, the serum concentration of the biomarker EGFR (epidermal growth factor receptor) and prescription BED. This predictive model recorded an area under the receiver operating characteristic curve of 0.94(1), providing better performance compared to competing methods in other literature. Conclusion: The use of biomarkers in conjunction with dose-volume metrics allows for the generation of a robust predictive model. The preliminary results of this report demonstrate that it is possible to accurately model the prognosis of an individual lung SBRT patient’s treatment.

60 APPLIED LIFE SCIENCES↗

Experimental Evaluation of the Fast-Neutron Passive Collar (FNPC) Performance and Comparison with Scintillation Based Collars

This report describes a new method for the verification of fresh low enrichment uranium (LEU) fuel assemblies that can reduce International Atomic Energy Agency (IAEA) inspection time in the field and be completely independent of operator declared burnable poison content. The passive measurement makes unattended mode operation practical, and thus provides the potential for reducing inspector time in the field for future applications. The new simplified passive neutron measurement uses the 238 U spontaneous fission in LEU fresh fuel rods to self-interrogate the 235 U mass in the neighboring rods. The measured response increases linearly with the increase in the linear density (LD) of 235 U. The relatively high efficiency of the passive neutron detector (24%) provides good statistical precision (~ 2%) for the singles, doubles, and triples counting rates in the thermal-neutron mode. The three observables makes possible multiplicity analysis so that both the 235 U LD and the effective burnable poison content can be determined independent of the operator declarations. This closes the potential diversion path of miss-declaration the burnable poison content. This report presents the detector design, the as-built system, the detector parameter measurements, the calibration, and the assay uncertainty estimates. The calibration measurements were performed using the Los Alamos Laboratory mockup PWR fuel assembly. The measurements were made in both the fastneutron mode (with Cd/Gd metal liners) and the thermal-neutron mode (no Cd/Gd liners).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Relevance of the Nuclear Quantum Effects on the Proton/Deuteron Transmission through Hexagonal Boron Nitride and Graphene Monolayers

According to recent experiments, atomically thin hexagonal boron nitride and graphene are permeable to protons and deuterons (and not to other atomic species), and the experimental estimates of the activation energy are lower than the theoretical values by about 0.5 eV for the isolated proton-membrane transfer model. Our analysis of the electronic potential energy surfaces along the normal to the transmission direction, obtained using correlated electronic structure methods, suggests that the aqueous environment is essential to stabilize the proton { as opposed to the hydrogenatom { transmission. Therefore, the process is examined within a molecular model of H 2 O { H(D) + { material { H 2 O. Exact quantum-mechanical scattering calculations are performed to assess the relevance of the nuclear quantum eects, such as tunneling factors and the kinetic isotope eect (KIE). Deuteration is found to aect the thermal reaction rate constants (KIE of 3-4 for hexagonal boron nitride and 20-30 for the graphene) and to eectively lower the barriers to the proton transfer by 0.2 and 0.4 eV for the two membranes, respectively. This lowering eect is reduced for the deuteron by approximately a factor of three. A more comprehensive description of the proton transmission is likely to require an extended explicit aqueous environment.

36 MATERIALS SCIENCE↗

Robust Copper-Based Nanosponge Architecture Decorated by Ruthenium with Enhanced Electrocatalytic Performance for Ambient Nitrogen Reduction to Ammonia

Electrochemical conversion of nitrogen to green ammonia is an attractive alternative to the Haber–Bosch process. However, it is currently bottlenecked by the lack of highly efficient electrocatalysts to drive the sluggish nitrogen reduction reaction (N2RR). In this work, we strategically design a cost-effective bimetallic Ru–Cu mixture catalyst in a nanosponge (NS) architecture via a rapid and facile method. The porous NS mixture catalysts exhibit a large electrochemical active surface area and enhanced specific activity arising from the charge redistribution for improved activation and adsorption of the activated nitrogen species. Benefiting from the synergistic effect of the Cu constituent on morphology decoration and thermodynamic suppression of the competing hydrogen evolution reaction, the optimized Ru 0.15 Cu 0.85 NS catalyst presents an impressive N 2 RR performance with an ammonia yield rate of 26.25 μg h –1 mg cat. –1 (corresponding to 10.5 μg h –1 cm –2 ) and Faradic efficiency of 4.39% as well as superior stability in alkaline medium, which was superior to that of monometallic Ru and Cu nanostructures. Additionally, this work develops a new bimetallic combination of Ru and Cu, which promotes the strategy to design efficient electrocatalysts for electrochemical ammonia production under ambient conditions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effect of Thermal Storage on the Emissions and Efficiency Performance of a Wood Pellet-Fired Residential Boiler

Wood pellet boilers for residential heating applications offer the promise of low emissions, high efficiency, and automatic operation. However, when operated in the field, these units operate often at very low loads causing them to cycle. In this study, the performance of a 25-kW modern pellet boiler under emulated field conditions and fixed nominal loads of 15% and 100% has been studied in a lab—with and without a buffer tank. A dilution tunnel approach was used for the measurement of particulate emissions, in accordance with U.S. certification testing requirements under EPA Methods 28 WHH and 28 WHH PTS. Results show that increasing the amount of thermal storage used decreases cycling rates leading to decreased emissions and increased efficiency. Without thermal storage, integrated efficiency over a 15% load test period was 57%, compared to 74% when thermal storage was used. Particulate emissions were 180 mg/MJ and 64 mg/MJ for the 15% load case without and with thermal storage, respectively.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Rapid synthesis of monodispersed highly porous spinel nickel cobaltite (NiCo{sub 2}O{sub 4}) electrode material for supercapacitors

Monodispersed highly porous spinel nickel cobaltite electrode material was successfully synthesized in a short time using combustion technique. Single phase cubic nature of the spinel nickel cobaltite with average crystallite size of 24 nm was determined from X-ray diffraction study. Functional groups present in the compound were determined from FTIR study and it further confirms the spinel formation. FESEM images reveal the porous nature of the prepared material and uniform size distribution of the particles. Electrochemical evaluation was performed using Cyclic Voltammetry (CV) technique, Chronopotentiometry (CP) and Electrochemical Impedance Spectroscopy (EIS). Results reveal the typical pseudocapacitive behaviour of the material. Maximum capacitance of 754 F/g was calculated at the scan rate of 5 mV/s, high capacitance was due to the unique porous morphology of the electrode. Nyquist plot depicts the low resistance and good electrical conductivity of nickel cobaltite. It has been found that nickel cobaltite prepared by this typical method will be a potential electrode material for supercapcitor application.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Spatiotemporally Adaptive Compression for Scientific Dataset with Feature Preservation – A Case Study on Simulation Data with Extreme Climate Events Analysis

Scientific discoveries are increasingly constrained by limited storage space and I/O capacities. For time-series simulations and experiments, their data often need to be decimated over timesteps to accommodate storage and I/O limitations. In this paper, we propose a technique that addresses storage costs while improving post-analysis accuracy through spatiotemporal adaptive, error-controlled lossy compression. We investigate the trade-off between data precision and temporal output rates, revealing that reducing data precision and increasing timestep frequency lead to more accurate analysis outcomes. Additionally, we integrate spatiotemporal feature detection with data compression and demonstrate that performing adaptive error-bounded compression in higher dimensional space enables greater compression ratios, leveraging the error propagation theory of a transformation-based compressor. To evaluate our approach, we conduct experiments using the well-known E3SM climate simulation code and apply our method to compress variables used for cyclone tracking. Our results show a significant reduction in storage size while enhancing the quality of cyclone tracking analysis, both quantitatively and qualitatively, in comparison to the prevalent timestep decimation approach. Compared to three state-of-the-art lossy compressors lacking feature preservation capabilities, our adaptive compression framework improves perfectly matched cases in TC tracking by 26.4-51.3% at medium compression ratios and by 77.3-571.1% at large compression ratios, with a merely 5–11% computational overhead.

Gong, Qian↗

SU-E-T-678: Response Calibration Using Electron Depth-Dose Data for MRI-Based 3D Polymer Gel Dosimetry

Purpose: To evaluate a calibration method using the depth-dose data of an electron beam for MRI-based polymer gel dosimetry. Methods: MAGAT was manufactured in-house to fill two 400mL-cylindrical phantoms and nine 22mL-glass vials. Phantom-A was irradiated along the cylinder axis with a 9MeV electron beam of 6 cm x 6 cm field size (FS). Phantom-B was irradiated with a 6MV photon beam of 3 cm x 3 cm FS by a 360-degree arc technique. Eight vials were irradiated in a water-bath to various doses with a 20 cm x 20 cm FS 6MV photon beam. All irradiated phantoms and one un-irradiated vial were scanned with a 3T MRI scanner to obtain the spin-spin relaxation rate (R2) distributions. By comparing the measured R2-to-depth data with the known depth-dose data for Phantom-A, R2-to-dose calibration data were obtained (e-beam method). Another calibration data were obtained from the 9 vials data (9-vial method). We tested two regression equations, i.e., third-order polynomial and tangent functions, and two dose normalization methods, i.e., one-point and two-point methods. Then, these two calibration methods were used to obtain the 3D dose distribution of Phantom-B and evaluated by comparing the measured data with the dose distribution from a treatment planning system. The comparison was made with gamma passing rate (2%/2mm criteria). Results: We did not observe a clear advantage of the e-beam method over the 9-vial method for the 3D dose comparison with the test case. Nevertheless, we found that the e-beam method required a smaller dose scaling for the dose comparison. Furthermore, the tangent function showed better data fitting than the polynomial function with smaller uncertainty of the estimated coefficients. Conclusions: Considering the overall superior performance, we recommend the e-beam method with the tangent function as the regression equation and one-point dose normalization for the MRI-based polymer gel dosimetry.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Poster - 22: Retrospective analysis of portal dosimetry based QA of Prostate VMAT Plans

Purpose: The purpose of this study is to retrospectively analyze the portal dosimetry based quality assurance of prostate VMAT plans. Methods: Our standard quality assurance of VMAT treatment plans are performed using EPID installed on Varian TrueBeam Linac. In our current study we analyzed 84 prostate pretreatment VMAT plans. All plans consisted of two arcs, 7800cGy in 39 fractions with a 6MV beam. For each of these VMAT plans, the measured fluence for each arc is compared with the reference fluence using gamma index analysis. Results: We have compared the gamma passing rates for three criteria; 3%/3mm, 2%/2mm and 1%/1mm. Out of 168 arcs measured, the number below the gamma passing rate 95% using the area, Field+1cm, are 0, 2, and 124 for 3%/3mm, 2%/2mm and 1%/1mm criteria respectively. Corresponding numbers for MLC CIAO are 0, 2, and 139 respectively. The average gamma passing rate for all arcs measured using Field+1cm are 99.9±0.4, 99.6±1.2, and 90.9±6.5 for 3%/3mm, 2%/2mm and 1%/1mm respectively. Similarly if the MLC CIAO area is analyzed, a passing rate of 99.9±0.2, 99.2±1.2 and 87.2±8.5 respectively was observed. The average of the maximum gamma was also found to increase with tighter criteria. Conclusion: Analysis of prostate VMAT quality assurance plans indicate that the gamma passing rate is sensitive to the criteria and the area analyzed.

60 APPLIED LIFE SCIENCES↗

Designing a parallel Feel-the-Way clustering algorithm on HPC systems

This paper introduces a new parallel clustering algorithm, named Feel-the-Way clustering algorithm, that provides better or equivalent convergence rate than the traditional clustering methods by optimizing the synchronization and communication costs. Our algorithm design centers on how to optimize three factors simultaneously: reduced synchronizations, improved convergence rate, and retained same or comparable optimization cost. To compare the optimization cost, we use the Sum of Square Error (SSE) cost as the metric, which is the sum of the square distance between each data point and its assigned clusters. Compared with the traditional MPI k-means algorithm, the new Feel-the-Way algorithm requires less communications among participating processes. As for the convergence rate, the new algorithm requires fewer number of iterations to converge. As for the optimization cost, it obtains the SSE costs that are close to the k-means algorithm. In the paper, we first design the full-step Feel-the-Way k-means clustering algorithm that can significantly reduce the number of iterations that are required by the original k-means clustering method. Next, we improve the performance of the full-step algorithm by adopting an optimized sampling-based approach, named reassignment-history-aware sampling. Our experimental results show that the optimized sampling-based Feel-the-Way method is significantly faster than the widely used k-means clustering method, and can provide comparable optimization costs. More extensive experiments with several synthetic datasets and real-world datasets (e.g., MNIST, CIFAR-10, ENRON, and PLACES-2) show that the new parallel algorithm can outperform the open source MPI k-means library by up to 110% on a high-performance computing system using 4,096 CPU cores. In addition, the new algorithm can take up to 51% fewer iterations to converge than the k-means clustering algorithm.

97 MATHEMATICS AND COMPUTING↗

Validation of Computational Fluid Dynamics Simulations for Biological Performance Assessment in Hydropower units (Final Report)

The biological performance assessment (BioPA) toolset developed by Pacific Northwest National Laboratory (PNNL) estimates the relative biological performance of fish passage at a hydroelectric power turbine unit. The tool is based on the use of computational fluid dynamics (CFD) and fish biological response relationships. The recent release, BioPA-v3, is based on directly computed trajectory and collision of material Lagrangian particles using CFD simulation codes rather than the prior version that relies on Tecplot to compute streamtrace trajectories. Before modifying the toolset, a series of validation tests were performed at the various steps of modification in the toolset. Validation is a critical step of any numerical investigation that reflects the accuracy and reliability of the predicted results. It raises the confidence level of the user to use the modified version of the BioPA toolset. Several test cases were simulated and compared, where available, to observed data. The trajectory and collision of the small spherical and cylindrical particles in a water flume were compared to in-house experiments. The CFD predicted collision rate and flow field compared well with experimental observation for vane array and large cylinder as target bodies. Next, the CFD-predicted flow field and hydraulic performance of a laboratory-scale model of a Francis turbine was also successfully validated. Note that the trajectory of the particles is significantly affected by the flow field in such extreme conditions. In addition to the particle trajectories and flow field, the collision detection method employed in the CFD simulations was also successfully validated. The CFD predicted impact velocity, collision time, velocity, and trajectory of a sphere excellently matched with analytical value for a bouncing ball in the elastic collision. A similar approach was also tested and successfully validated for a collision of sphere with a 45° inclined plane. After successfully validating different cases, the BioPA toolset was modified to use direct output of the CFD prediction and the new version can be used in evaluating biological performance at hydroelectric turbines.

13 HYDRO ENERGY↗

SU-F-T-54: Determination of the AAPM TG-43 Brachytherapy Dosimetry Parameters for A New Titanium-Encapsulated Yb-169 Source by Monte Carlo Calculations

Purpose: To determine the AAPM TG-43 brachytherapy dosimetry parameters of a new titanium-encapsulated Yb-169 source designed to maximize the dose enhancement during gold nanoparticle-aided radiation therapy (GNRT). Methods: An existing Monte Carlo (MC) model of the titanium-encapsulated Yb-169 source, which was described in the current investigators’ published MC optimization study, was modified based on the source manufacturer’s detailed specifications, resulting in an accurate model of the titanium-encapsulated Yb-169 source that was actually manufactured. MC calculations were then performed using the MCNP5 code system and the modified source model, in order to obtain a complete set of the AAPM TG-43 parameters for the new Yb-169 source. Results: The MC-calculated dose rate constant for the new titanium-encapsulated Yb-169 source was 1.05 ± 0.03 cGy per hr U, indicating about 10% decrease from the values reported for the conventional stainless steel-encapsulated Yb-169 sources. The source anisotropy and radial dose function for the new source were found similar to those reported for the conventional Yb-169 sources. Conclusion: In this study, the AAPM TG-43 brachytherapy dosimetry parameters of a new titanium-encapsulated Yb-169 source were determined by MC calculations. The current results suggested that the use of titanium, instead of stainless steel, to encapsulate the Yb-169 core would not lead to any major change in the dosimetric characteristics of the Yb-169 source, while it would allow more low energy photons being transmitted through the source filter thereby leading to an increased dose enhancement during GNRT. Supported by DOD/PCRP grant W81XWH-12-1-0198 This investigation was supported by DOD/PCRP grant W81XWH-12-1- 0198.

60 APPLIED LIFE SCIENCES↗

Single Crystalline Na 0.67 Ni 0.33 Mn 0.67 O 2 Positive Electrode Material via Molten Salt Synthesis for Sodium Ion Batteries

P2-layered Na 0.67 Ni 0.33 Mn 0.67 O 2 (NNMO) has emerged as a promising positive electrode material for sodium ion batteries due to its appealing electrochemical properties. Synthesis of polycrystalline NNMO (PC-NNMO) materials through conventional calcination of solid precursors remains the prevailing method, where heating occurs in a dry environment with air or O 2 . On the other hand, the molten salt method, where precursors are submerged in molten salt medium during calcination, emerged in recent years to be a scalable technique for more controlled crystal growth and uniform morphology in a variety of materials. Here, we utilize the molten salt method to synthesize single crystalline NNMO (SC-NNMO) materials with enhanced electrochemical properties. The SC-NNMO material exhibits an initial specific discharge capacity of 95 mAh g –1 at a 0.1C rate, retaining approximately 88.5% of its capacity after 100 cycles over a wide voltage range of 2.0–4.2 V. Furthermore, SC-NNMO maintains a capacity retention of 83.9% after 300 cycles at a 1C rate compared to 66.6% for PC-NNMO, indicating excellent long-term cycling stability. This stability is further confirmed by the performance of an SC-NNMO//hard carbon full cell, which retains 90.3% of its capacity after 200 cycles at 1C within a voltage window of 1.9–4.1 V. The enhancement in stability of the SC-NNMO sample is attributed to the single crystalline structure suppressing the undesired P2–O2 phase transition at high voltage. This study also presents an easy, efficient, and straightforward molten salt process for SC-NNMO material synthesis, offering valuable insights into the potential application of such methodology for the large-scale, cost-effective production of various sodium-layered transition metal oxide positive electrode materials for SIBs.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Reducing Uncertainty of Fielded Photovoltaic Performance (Final Technical Report)

Improved analysis and reporting of photovoltaic (PV) field performance increases the certainty of owners and financiers that systems will perform as expected. Advanced module technologies (e.g., PERC, HJT, and bifacial) introduce new degradation mechanisms and performance characteristics. The FY19-21 Reducing Uncertainty project leveraged data from the ever-increasing PV fleet to develop models and understanding of the field performance of existing and new technologies. Specifically, we accomplished: report on field performance and degradation rates for high-efficiency silicon (HJT, PERC, IBC) and more conventional technologies; developed automated analysis techniques to quantify system performance (performance ratio, energy yield) and production shortfalls (soiling, degradation, availability); refined the RdTools software toolkit to bring standard, validated analysis techniques to bear on third-party data; analyzed and reported on large datasets including Treasury data and Lawrence Berkeley National Laboratory's Utility-Scale dataset to expand the high-quality degradation-rate histogram published previously; worked with industry partners and the DuraMAT data hub to enable private parties to share and aggregate PV production data anonymously, leveraging cloud-based data analysis infrastructure and publishing on US fleet-scale performance comprising over 7GW of operating systems. (https://www.nrel.gov/pv/fleet-performance-data-initiative.html). Through our industry collaborations we have engaged in NDA-covered data transfer with twelve PV fleet owners as of January 2022, with more agreements in negotiation. Our scalable cloud-based time series database contains over 30 billion rows (20TB) of PV time series data, representing over 1700 commercial and utility-scale systems, and over 7.2 GW of DC capacity (Fig 1). Initial field performance results have been distributed in several public reports. Because our fleet composition and data quality methods are continually improving, annual updates to these results are published to our PV Fleet webpage [ https://www.nrel.gov/pv/fleet-performance-data-initiative.html ] and DuraMAT data hub [DOI: 10.21948/1842958]. Another existing dissemination channel used for observed soiling losses is a map we maintain for soiling losses. Additional products developed include a report detailing fleet-wide performance index, availability, startup loss and snow loss factors, a detailed report on the 1603 grant dataset comprising over 100,000 PV systems with failure and performance details and a utility-scale report coauthored with LBNL on 31 GW of system performance.

14 SOLAR ENERGY↗

MVP™ Micro Vascular Plug Systems for the Treatment of Pulmonary Arteriovenous Malformations

Purpose: To describe our institutional experience with MVP™ micro vascular plug systems for the treatment of pulmonary arteriovenous malformations (PAVMs). Materials and Methods: We performed a retrospective medical record review of 52 patients with 119 PAVMs treated exclusively with MVP™ systems (69 procedures/153 MVP™ systems) between July 2014 and July 2018. All patients had PAVMs with feeding artery diameters ≥ 2 mm. MVP™ systems were deployed according to physician preference. We collected patient demographic information; procedural data (including size of feeding artery, size and number of embolics used per PAVM, fluoroscopy time, contrast administration), technical success rates, complications, and persistence. Persistence was assessed using computed tomography angiography (CTA) performed 1–3 months and 3–5 years after embolization per clinical protocol. Results: All procedures were technically successful without major complications. Mean feeding artery diameter was 3.3 ± 1.2 mm. Mean fluoroscopy time per procedure and contrast volume administered per procedure were 35 ± 16 min and 217 ± 101 mL, respectively. A mean of 1.3 ± 0.8 MVP™ systems was used per PAVM. There were no instances of persistence during a mean follow-up time of 328 ± 258 days (range 26 to 914 days). Conclusions: For PAVMs with feeding artery diameters of 2 to 7.9 mm (mean 3.3 ± 1.2 mm), MVP™ systems are safe and effective given their high technical success rates and lack of persistence. Further prospective work will be required to elucidate the advantages and disadvantages of these MVP™ systems for PAVM embolization. Level of Evidence: Level III.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

From electronic structure to model application of key reactions for gasoline/alcohol combustion: Hydrogen-atom abstractions by $CH_3\dot{O}$ radical

H-atom abstraction by methoxy radical ($CH_3\dot{O}$) plays an important role in capturing the kinetics of reactions between gasoline components and alcohols. This study focuses on determining the reaction rates and thermodynamic properties of methoxy radical reactions with five gasoline fuel components: n-heptane, iso-octane, 1-hexene, cyclopentane and toluene. Electronic structure calculations were per-formed for all the stationary points with M06-2X/6 -311 ++ g(d,p) method. G3 composite method with atomization method is used for determining Δ f H 0 of all the closed shell and radical species, using which the necessary thermodynamic data of all the species was determined. Coupled cluster theory QCISD(T)/cc-pVXZ (where X = D and T) and Møller-Plesset perturbation theory MP2/cc-pVXZ (where X = D, T and Q) were used to calculate single point energies. Subsequently, rate constants for all hydrogen atom ab-straction channels have been performed using conventional transition state theory with unsymmetric tunneling corrections. A systematic comparison of rates for abstraction from different sites within the same species and same site from different species is done in order to get insights into this reaction class. Here, the computed thermodynamic properties and rate constants were incorporated into a recent gasoline mechanism to investigate the impact of the calculations performed in this work. A shift in predicted NTC (negative temperature coefficient) behavior and significant reduction in model reactivity is observed upon incorporating the rates calculated herein.

33 ADVANCED PROPULSION SYSTEMS↗