Search NASA⌕ Search

SEARCH · Search NASA

Results for “Positioning System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

Patterns and Risk Factors of Locoregional Recurrence in T1-T2 Node Negative Breast Cancer Patients Treated With Mastectomy: Implications for Postmastectomy Radiotherapy

Purpose: Postmastectomy radiation therapy (PMRT) can reduce locoregional recurrences (LRR) in high-risk patients, but its role in the treatment of lymph node negative (LN-) breast cancer remains unclear. The aim of this study was to identify a subgroup of T1-T2 breast cancer patients with LN- who might benefit from PMRT. Methods and Materials: We retrospectively reviewed 1,136 node-negative T1-T2 breast cancer cases treated with mastectomy without PMRT at the Massachusetts General Hospital between 1980 and 2004. We estimated cumulative incidence rates for LRR overall and in specific subgroups, and used Cox proportional hazards models to identify potential risk factors. Results: Median follow-up was 9 years. The 10-year cumulative incidence of LRR was 5.2% (95% CI: 3.9-6.7%). Chest wall was the most common (73%) site of LRR. Tumor size, margin, patient age, systemic therapy, and lymphovascular invasion (LVI) were significantly associated with LRR on multivariate analysis. These five variables were subsequently used as risk factors for stratified analysis. The 10-year cumulative incidence of LRR for patients with no risk factors was 2.0% (95% CI: 0.5-5.2%), whereas the incidence for patients with three or more risk factors was 19.7% (95% CI: 12.2-28.6%). Conclusion: It has been suggested that patients with T1-T2N0 breast cancer who undergo mastectomy represent a favorable group for which PMRT renders little benefit. However, this study suggests that select patients with multiple risk factors including LVI, tumor size {>=}2 cm, close or positive margin, age {<=}50, and no systemic therapy are at higher risk of LRR and may benefit from PMRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optimization based process modeling of an anaerobic membrane bioreactor system: Application to swine wastewater

To maintain current levels of consumption in the economy with the dwindling supply of non-renewable material and energy, alternative resource streams more traditionally viewed as waste streams must be considered. Fermentation of high-strength wastewaters is one such pathway that allows for the recovery of energy, nitrogen, phosphorus, and carbon compounds. Anaerobic membrane bioreactors (AnMBRs) are an emerging technology that allow for the digestion of wastewater in a much smaller footprint than traditional anaerobic digesters. Adoption of this technology into industry has been limited by membrane capital and cleaning costs, but these costs may be offset through the recovery of valuable products. To evaluate the viability of AnMBR technology in the context of swine wastewater treatment, an optimization-based process model built upon Anaerobic Digestion Model No. 1 (ADM1) has been developed. Modeling results show that a swine wastewater stream provides potential for net positive energy generation from the AnMBR system in most cases. Sensitivity analyses around important variables were conducted to determine focus areas for future research into AnMBR technology and evaluate the robustness of the model to microbial variables that may change with different microbial communities.

09 BIOMASS FUELS↗

SU-F-T-644: Reproducibility of Target Position Using Moderate Voluntary Breath- Hold During Liver Stereotactic Ablative Radiotherapy

Purpose: To evaluate the reproducibility of target position using moderate voluntary breath-hold during liver stereotactic ablative radiotherapy (SABR). Methods: Two patients who underwent liver SABR on a Varian TrueBeam STx linac were used for this study. Fiducial markers were placed in and around the target in the liver as surrogates for the target position and motion. GTVs were contoured by assessing tumor extent on contrast enhanced CT. The PTV was created from the GTV by adding 2 mm margins to account for the residual motion during breath-holds. A portable biofeedback system was used to facilitate the breath-hold to a reproducible position. The Varian RPM system was used for gating the linac. Proceeding each treatment, orthogonal kV pairs were taken, and alignment to nearby bony anatomy was performed. Then the breath-hold CBCT was acquired to align the fiducial markers. On-line fluoroscopy was used to fine-tune the breath-hold gating thresholds to correlate with the positions of the fiducial markers. The inter-fraction reproducibility of the target was evaluated by the offsets of the daily breath-hold CBCTs from the paired kV matches as a direct measure of the target position relative to the bony anatomy. The intra-fraction reproducibility of the target position was assessed by the gated window of the RPM marker block for each fraction. Results: The absolute mean offsets between the CBCT and paired kV matches in the vertical, longitudinal, and lateral directions were 0.06 cm, 0.10 cm, and 0.06 cm for patient 1, and 0.37 cm, 0.62 cm, and 0.09 cm for patient 2. The gated window of the RPM marker block for the breath-hold for each fraction was within 0.63 ± 0.16 cm and 0.59 ± 0.12 cm for patients 1 and 2, respectively. Conclusion: Moderate voluntary breath-hold showed good inter- and intra-fraction reproducibility of target position during liver SABR.

60 APPLIED LIFE SCIENCES↗

Status of the RF BPM upgrade at the Advanced Photon Source.

The Advanced Photon Source (APS),a third-generation synchrotron light source, has been in operation for eleven years. The monopulse radio frequency (rf) beam position monitor (BPM) is one of three BPM types now employed in the storage ring at the APS. It is a broadband (10 MHz) system designed to measure single-turn and multi-turn beam positions, but it suffers from an aging data acquisition system. The replacement BPM system retains the existing monopulse receivers and replaces the data acquisition system with high-speed analog-to-digital converters (ADCs) and a field-programmable gate array (FPGA) that performs the signal processing. A first-article system has been constructed and is currently being evaluated. This paper presents the results of testing of the first-article system as well as the progress made in other areas of this upgrade effort.

43 PARTICLE ACCELERATORS↗

THE PPMXL CATALOG OF POSITIONS AND PROPER MOTIONS ON THE ICRS. COMBINING USNO-B1.0 AND THE TWO MICRON ALL SKY SURVEY (2MASS)

USNO-B1.0 and the Two Micron All Sky Survey (2MASS) are the most widely used all-sky surveys. However, 2MASS has no proper motions at all, and USNO-B1.0 published only relative, not absolute (i.e., on the International Celestial Reference Frame (ICRS), proper motions. We performed a new determination of mean positions and proper motions on the ICRS system by combining USNO-B1.0 and 2MASS astrometry. This catalog is called PPMXL (VO access to the catalog is possible via http://vo.uni-hd.de/ppmxl), and it aims to be completed from the brightest stars down to about V {approx} 20 all sky. PPMXL contains about 900 million objects, some 410 million with 2MASS photometry, and is the largest collection of ICRS proper motions at present. As representative for the ICRS, we chose PPMX. The recently released UCAC3 could not be used because we found plate-dependent distortions in its proper motion system north of -20{sup 0} declination. UCAC3 served as an intermediate system for {delta} {<=} -20{sup 0}. The resulting typical individual mean errors of the proper motions range from 4 mas yr{sup -1} to more than 10 mas yr{sup -1} depending on observational history. The mean errors of positions at epoch 2000.0 are 80-120 mas, if 2MASS astrometry could be used, 150-300 mas else. We also give correction tables to convert USNO-B1.0 observations of, e.g., minor planets to the ICRS system.

79 ASTRONOMY AND ASTROPHYSICS↗

Development and clinical evaluation of automatic fiducial detection for tumor tracking in cine megavoltage images during volumetric modulated arc therapy

Purpose: Real-time tracking of implanted fiducials in cine megavoltage (MV) imaging during volumetric modulated arc therapy (VMAT) delivery is complicated due to the inherent low contrast of MV images and potential blockage of dynamic leaves configurations. The purpose of this work is to develop a clinically practical autodetection algorithm for motion management during VMAT. Methods: The expected field-specific segments and the planned fiducial position from the Eclipse (Varian Medical Systems, Palo Alto, CA) treatment planning system were projected onto the MV images. The fiducials were enhanced by applying a Laplacian of Gaussian filter in the spatial domain for each image, with a blob-shaped object as the impulse response. The search of implanted fiducials was then performed on a region of interest centered on the projection of the fiducial when it was within an open field including the case when it was close to the field edge or partially occluded by the leaves. A universal template formula was proposed for template matching and normalized cross correlation was employed for its simplicity and computational efficiency. The search region for every image was adaptively updated through a prediction model that employed the 3D position of the fiducial estimated from the localized positions in previous images. This prediction model allowed the actual fiducial position to be tracked dynamically and was used to initialize the search region. The artifacts caused by electronic interference during the acquisition were effectively removed. A score map was computed by combining both morphological information and image intensity. The pixel location with the highest score was selected as the detected fiducial position. The sets of cine MV images taken during treatment were analyzed with in-house developed software written in MATLAB (The Mathworks, Inc., Natick, MA). Five prostate patients were analyzed to assess the algorithm performance by measuring their positioning accuracy during treatment. Results: The algorithm was able to accurately localize the fiducial position on MV images with success rates of more than 90% per case. The percentage of images in which each fiducial was localized in the studied cases varied between 23% and 65%, with at least one fiducial having been localized between 40% and 95% of the images. This depended mainly on the modulation of the plan and fiducial blockage. The prostate movement in the presented cases varied between 0.8 and 3.5 mm (mean values). The maximum displacement detected among all patients was of 5.7 mm. Conclusions: An algorithm for automatic detection of fiducial markers in cine MV images has been developed and tested with five clinical cases. Despite the challenges posed by complex beam aperture shapes, fiducial localization close to the field edge, partial occlusion of fiducials, fast leaf and gantry movement, and inherently low MV image quality, good localization results were achieved in patient images. This work provides a technique for enabling real-time accurate fiducial detection and tumor tracking during VMAT treatments without the use of extra imaging dose.

60 APPLIED LIFE SCIENCES↗

The evaluation of a 2D diode array in “magic phantom” for use in high dose rate brachytherapy pretreatment quality assurance

Purpose: High dose rate (HDR) brachytherapy is a treatment method that is used increasingly worldwide. The development of a sound quality assurance program for the verification of treatment deliveries can be challenging due to the high source activity utilized and the need for precise measurements of dwell positions and times. This paper describes the application of a novel phantom, based on a 2D 11 × 11 diode array detection system, named “magic phantom” (MPh), to accurately measure plan dwell positions and times, compare them directly to the treatment plan, determine errors in treatment delivery, and calculate absorbed dose. Methods: The magic phantom system was CT scanned and a 20 catheter plan was generated to simulate a nonspecific treatment scenario. This plan was delivered to the MPh and, using a custom developed software suite, the dwell positions and times were measured and compared to the plan. The original plan was also modified, with changes not disclosed to the primary authors, and measured again using the device and software to determine the modifications. A new metric, the “position–time gamma index,” was developed to quantify the quality of a treatment delivery when compared to the treatment plan. The MPh was evaluated to determine the minimum measurable dwell time and step size. The incorporation of the TG-43U1 formalism directly into the software allows for dose calculations to be made based on the measured plan. The estimated dose distributions calculated by the software were compared to the treatment plan and to calibrated EBT3 film, using the 2D gamma analysis method. Results: For the original plan, the magic phantom system was capable of measuring all dwell points and dwell times and the majority were found to be within 0.93 mm and 0.25 s, respectively, from the plan. By measuring the altered plan and comparing it to the unmodified treatment plan, the use of the position–time gamma index showed that all modifications made could be readily detected. The MPh was able to measure dwell times down to 0.067 ± 0.001 s and planned dwell positions separated by 1 mm. The dose calculation carried out by the MPh software was found to be in agreement with values calculated by the treatment planning system within 0.75%. Using the 2D gamma index, the dose map of the MPh plane and measured EBT3 were found to have a pass rate of over 95% when compared to the original plan. Conclusions: The application of this magic phantom quality assurance system to HDR brachytherapy has demonstrated promising ability to perform the verification of treatment plans, based upon the measured dwell positions and times. The introduction of the quantitative position–time gamma index allows for direct comparison of measured parameters against the plan and could be used prior to patient treatment to ensure accurate delivery.

60 APPLIED LIFE SCIENCES↗

X-ray computed tomography to predict soil N 2 O production via bacterial denitrification and N 2 O emission in contrasting bioenergy cropping systems

While renewable biofuels can reduce negative effects of fossil fuel energy consumption, the magnitude of their benefits depends on the magnitude of N 2 O emissions. High variability of N 2 O emissions overpowers efforts to curb uncertainties in estimating N 2 O fluxes from biofuel systems. In this study, we explored (a) N 2 O production via bacterial denitrification and (b) N 2 O emissions from soils under several contrasting bioenergy cropping systems, with specific focus on explaining N 2 O variations by accounting for soil pore characteristics. Intact soil samples were collected after 9 years of implementing five biofuel systems: continuous corn with and without winter cover crop, monoculture switchgrass, poplars, and early–successional vegetation. After incubation, N 2 O emissions were measured and bacterial denitrification was determined based on the site–preference method. Soil pore characteristics were quantified using X–ray computed microtomography. Three bioenergy systems with low plant diversity, that is, corn and switchgrass systems, had low porosities, low organic carbon contents, and large volumes of poorly aerated soil. In these systems, greater volumes of poorly aerated soil were associated with greater bacterial denitrification, which in turn was associated with greater N 2 O emissions ( R 2 = 0.52, p < 0.05). However, the two systems with high plant diversity, that is, poplars and early–successional vegetation, over the 9 years of implementation had developed higher porosities and organic carbon contents. In these systems, volumes of poorly aerated soil were positively associated with N 2 O emissions without a concomitant increase in bacterial denitrification. Our results suggest that changes in soil pore architecture generated by long–term implementation of contrasting bioenergy systems may affect the pathways of N 2 O production, thus, change associations between N 2 O emissions and other soil properties. In conclusion, plant diversity appears as one of the factors determining which microscale soil characteristics will influence the amounts of N 2 O emitted into the atmosphere and, thus, which can be used as effective empirical predictors.

59 BASIC BIOLOGICAL SCIENCES↗

Efficacy of acetate-amended biostimulation for uranium sequestration: Combined analysis of sediment/groundwater geochemistry and bacterial community structure

Systematic flow-through column experiments were conducted using sediments and ground water collected from different subsurface localities at the U.S. Department of Energy's Integrated Field Research Challenge site in Rifle, Colorado. The principal purpose of this study is to gain a better understanding of the interactive effects of groundwater geochemistry, sediment mineralogy, and indigenous bacterial community structures on the efficacy of uranium removal from the groundwater with/without acetate amendment. Overall, we find that the subtle variations in the sediments' mineralogy, particle size, redox conditions, as well as contents of metal(loid) co-contaminants showed a pronounced effect on the associated bacterial population and composition, which mainly determines the system's performance with respect to uranium removal. Positive relationship was identified between the abundance of dissimilatory sulfate-reduction genes (i.e., drsA), markers of sulfatereducing bacteria, and the sediments' propensity to sequester aqueous uranium. In contrast, no obvious connections were observed between the abundance of common iron-reducing bacteria, e.g., Geobacter spp., and the sediments' ability to sequester uranium. In the sediments with low bacterial biomass and the absence of sulfate-reducing conditions, abiotic adsorption onto mineral surfaces such as phyllosilicates likely played a relatively major role in the attenuation of aqueous uranium; however, in these scenarios, acetate amendment induced detectable rebounds in the effluent uranium concentrations. The results of this study suggest that reductive immobilization of uranium can be achieved under predominantly sulfate-reducing conditions, and provide insight into the integrated roles of various biogeochemical components in long-term uranium sequestration.

58 GEOSCIENCES↗

Reliability of EUCLIDIAN: An autonomous robotic system for image-guided prostate brachytherapy

Purpose: Recently, several robotic systems have been developed to perform accurate and consistent image-guided brachytherapy. Before introducing a new device into clinical operations, it is important to assess the reliability and mean time before failure (MTBF) of the system. In this article, the authors present the preclinical evaluation and analysis of the reliability and MTBF of an autonomous robotic system, which is developed for prostate seed implantation. Methods: The authors have considered three steps that are important in reliability growth analysis. These steps are: Identification and isolation of failures, classification of failures, and trend analysis. For any one-of-a-kind product, the reliability enhancement is accomplished through test-fix-test. The authors have used failure mode and effect analysis for collection and analysis of reliability data by identifying and categorizing the failure modes. Failures were classified according to severity. Failures that occurred during the operation of this robotic system were considered as nonhomogenous Poisson process. The failure occurrence trend was analyzed using Laplace test. For analyzing and predicting reliability growth, commonly used and widely accepted models, Duane's model and the Army Material Systems Analysis Activity, i.e., Crow's model, were applied. The MTBF was used as an important measure for assessing the system's reliability. Results: During preclinical testing, 3196 seeds (in 53 test cases) were deposited autonomously by the robot and 14 critical failures were encountered. The majority of the failures occurred during the first few cases. The distribution of failures followed Duane's postulation as well as Crow's postulation of reliability growth. The Laplace test index was -3.82 (<0), indicating a significant trend in failure data, and the failure intervals lengthened gradually. The continuous increase in the failure occurrence interval suggested a trend toward improved reliability. The MTBF was 592 seeds, which implied that several prostate seed implantation cases would be possible without encountering any critical failure. The shape parameter for the MTBF was 0.3859 (<1), suggesting a positive reliability growth of this robotic system. At 95% confidence, the reliability for deposition of 65 seeds was more than 90%. Conclusions: Analyses of failure mode strongly indicated a gradual improvement of reliability of this autonomous robotic system. High MTBF implied that several prostate seed implant cases would be possible without encountering any critical failure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Electronics Systems for the Gamma Ray Energy Tracking Nuclear Array (GRETA)

The Gamma Ray Energy Tracking Nuclear Array (GRETA), a 4-π germanium detector system capable of measuring energy and position (within better than 2mm rms) of gamma-ray interaction points and tracking multiple gamma-ray interactions, is being designed. GRETA is composed of 30 detector modules, each with four high purity germanium crystals. Four electronics modules will support the operation of the detectors: the Digitizer Module, the Signal Filter Board and the Trigger and Timing Modules. The Digitizer Module converts the analog information with analog to digital converters operating at 100 MS/s and sends the conversions through fiber optics to the Signal Filter Board. The Signal Filter Board digitally processes the data to determine the energy and timing information of the gamma interactions within a crystal. The Digitizer and Signal Filter Board send trigger information to the Trigger System. Different trigger algorithms for trigger decision are planned for the Trigger System. The Timing System provides the clock for the electronics systems and auxiliary detectors. In this paper we review the details of the planned GRETA Electronics System.

data acquisition↗

Patient positioning in radiotherapy based on surface imaging using time of flight cameras

Purpose: To evaluate the patient positioning accuracy in radiotherapy using a stereo-time of flight (ToF)-camera system. Methods: A system using two ToF cameras was used to scan the surface of the patients in order to position them daily on the treatment couch. The obtained point clouds were registered to (a) detect translations applied to the table (intrafraction motion) and (b) predict the displacement to be applied in order to place the patient in its reference position (interfraction motion). The measures provided by this system were compared to the effectively applied translations. The authors analyzed 150 fractions including lung, pelvis/prostate, and head and neck cancer patients. Results: The authors obtained small absolute errors for displacement detection: 0.8 ± 0.7, 0.8 ± 0.7, and 0.7 ± 0.6 mm along the vertical, longitudinal, and lateral axes, respectively, and 0.8 ± 0.7 mm for the total norm displacement. Lung cancer patients presented the largest errors with a respective mean of 1.1 ± 0.9, 0.9 ± 0.9, and 0.8 ± 0.7 mm. Conclusions: The proposed stereo-ToF system allows for sufficient accuracy and faster patient repositioning in radiotherapy. Its capability to track the complete patient surface in real time could allow, in the future, not only for an accurate positioning but also a real time tracking of any patient intrafraction motion (translation, involuntary, and breathing).

60 APPLIED LIFE SCIENCES↗

Algebraic function operator expectation value based quantum eigenstate determination: A case of twisted or bent Hamiltonian, or, a spatially univariate quantum system on a curved space

Recent studies on quantum evolutionary problems in Demiralp’s group have arrived at a stage where the construction of an expectation value formula for a given algebraic function operator depending on only position operator becomes possible. It has also been shown that this formula turns into an algebraic recursion amongst some finite number of consecutive elements in a set of expectation values of an appropriately chosen basis set over the natural number powers of the position operator as long as the function under consideration and the system Hamiltonian are both autonomous. This recursion corresponds to a denumerable infinite number of algebraic equations whose solutions can or can not be obtained analytically. This idea is not completely original. There are many recursive relations amongst the expectation values of the natural number powers of position operator. However, those recursions may not be always efficient to get the system energy values and especially the eigenstate wavefunctions. The present approach is somehow improved and generalized form of those expansions. We focus on this issue for a specific system where the Hamiltonian is defined on the coordinate of a curved space instead of the Cartesian one.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Heavy Ion-Acoustic Solitary Waves and Double Layers in a Multi-Ion Plasma

The formation and propagation of small-amplitude heavy-ion-acoustic (HIA) solitary waves and double layers in an unmagnetized collisionless multicomponent plasma system consisting of superthermal electrons, Boltzmann distributed light ions, and adiabatic positively charged inertial heavy ions are theoretically investigated. The reductive perturbation technique is employed to derive the modified Korteweg–de Vries (mKdV) and standard Gardner (SG) equations. The solitary wave (SW) solution of mKdV and SG equations, as well as double layers (DLs) solution of SG equation, is studied for analysis of higher order nonlinearity. It is found that the plasma system under consideration supports positive and negative potential Gardner solitons, but only positive potential mKdV solitons. In addition, it is shown that, the basic properties of HIA mKdV and Gardner solitons and DLs (viz. polarity, amplitude, width, and phase speed) are incomparably influenced by the adiabaticity effect of heavy ions and the superthermality effect of electrons. The relevance of the present findings to the system of space plasmas, as well as to the system of researchers interest, is specified.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Results of a Multi-Institutional Benchmark Test for Cranial CT/MR Image Registration

Purpose: Variability in computed tomography/magnetic resonance imaging (CT/MR) cranial image registration was assessed using a benchmark case developed by the Quality Assurance Review Center to credential institutions for participation in Children's Oncology Group Protocol ACNS0221 for treatment of pediatric low-grade glioma. Methods and Materials: Two DICOM image sets, an MR and a CT of the same patient, were provided to each institution. A small target in the posterior occipital lobe was readily visible on two slices of the MR scan and not visible on the CT scan. Each institution registered the two scans using whatever software system and method it ordinarily uses for such a case. The target volume was then contoured on the two MR slices, and the coordinates of the center of the corresponding target in the CT coordinate system were reported. The average of all submissions was used to determine the true center of the target. Results: Results are reported from 51 submissions representing 45 institutions and 11 software systems. The average error in the position of the center of the target was 1.8 mm (1 standard deviation = 2.2 mm). The least variation in position was in the lateral direction. Manual registration gave significantly better results than did automatic registration (p = 0.02). Conclusion: When MR and CT scans of the head are registered with currently available software, there is inherent uncertainty of approximately 2 mm (1 standard deviation), which should be considered when defining planning target volumes and PRVs for organs at risk on registered image sets.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantum Dynamics of Multi Harmonic Oscillators Described by Time Variant Conic Hamiltonian and their Use in Contemporary Sciences

This work focuses on the dynamics of a system of quantum multi harmonic oscillators whose Hamiltonian is conic in positions and momenta with time variant coefficients. While it is simple, this system is useful for modeling the dynamics of a number of systems in contemporary sciences where the equations governing spatial or temporal changes are described by sets of ODEs. The dynamical causal models used readily in neuroscience can be indirectly described by these systems. In this work, we want to show that it is possible to describe these systems using quantum wave function type entities and expectations if the dynamic of the system is related to a set of ODEs.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Filter accuracy for the Lorenz 96 model: Fixed versus adaptive observation operators

In the context of filtering chaotic dynamical systems it is well-known that partial observations, if sufficiently informative, can be used to control the inherent uncertainty due to chaos. The purpose of this paper is to investigate, both theoretically and numerically, conditions on the observations of chaotic systems under which they can be accurately filtered. In particular, we highlight the advantage of adaptive observation operators over fixed ones. The Lorenz ’96 model is used to exemplify our findings. Here, we consider discrete-time and continuous-time observations in our theoretical developments. We prove that, for fixed observation operator, the 3DVAR filter can recover the system state within a neighbourhood determined by the size of the observational noise. It is required that a sufficiently large proportion of the state vector is observed, and an explicit form for such sufficient fixed observation operator is given. Numerical experiments, where the data is incorporated by use of the 3DVAR and extended Kalman filters, suggest that less informative fixed operators than given by our theory can still lead to accurate signal reconstruction. Adaptive observation operators are then studied numerically; we show that, for carefully chosen adaptive observation operators, the proportion of the state vector that needs to be observed is drastically smaller than with a fixed observation operator. Indeed, we show that the number of state coordinates that need to be observed may even be significantly smaller than the total number of positive Lyapunov exponents of the underlying system.

3DVAR↗

Solute location in a nanoconfined liquid depends on charge distribution

Nanostructured materials that can confine liquids have attracted increasing attention for their diverse properties and potential applications. Yet, significant gaps remain in our fundamental understanding of such nanoconfined liquids. Using replica exchange molecular dynamics simulations of a nanoscale, hydroxyl-terminated silica pore system, we determine how the locations explored by a coumarin 153 (C153) solute in ethanol depend on its charge distribution, which can be changed through a charge transfer electronic excitation. The solute position change is driven by the internal energy, which favors C153 at the pore surface compared to the pore interior, but less so for the more polar, excited-state molecule. This is attributed to more favorable non-specific solvation of the large dipole moment excited-state C153 by ethanol at the expense of hydrogen-bonding with the pore. It is shown that a change in molecule location resulting from shifts in the charge distribution is a general result, though how the solute position changes will depend upon the specific system. This has important implications for interpreting measurements and designing applications of mesoporous materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗