Search NASA⌕ Search

SEARCH · Search NASA

Results for “Power Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

Development of Real-Time Quantitative Safety Evaluation Method for Nuclear Power Plants

Human operators involved with large process control systems such as nuclear power plants (NPPs) perform significant roles in the operation of systems. In this reason, deficiencies in human factors such as poor HSI (Human System Interface) design, procedure, and training, are significant contributing factors to NPPs incidents and accidents. In this regard, many kinds of studies including human reliability analysis (HRA), operation support system, automation, have been conducted in order to reduce human errors. Among these fields of studies, automation has its own specialty since it mainly focuses on eliminating the human error-inducing tasks to reduce human error, while other topics are primarily focusing on reducing human error by aiding human operators during operation. It is commonly believed that replacing human operators to the automated system would guarantee greater efficiency, lower workloads, and fewer human errors. However, these beliefs are not always true in large and complex systems such as NPP, since excessive automation can generate new roles for human operators, change human operators' activities in unexpected ways, and inducing 'out-of-the-loop' (OOTL) problem. Especially, although human error probability drastically increases during abnormal situations in NPP due to overload of information, high workload, and short time available for diagnosis, automation is not actively adopted since conventional machine learning techniques are neither capable nor reliable to handle overwhelmingly complex abnormal situations in NPP. Recently, newly developed 'deep learning' techniques have been actively applied to many fields, and some of these studies proved that the artificial intelligences (AI) based on deep learning techniques show better performance than that of human being. In 2015, deep Q-network (DQN) which is one of the deep learning techniques was developed and applied to train AI that automatically plays various Atari 2800 games, and this AI surpassed the human-level playing in many kind of games. Also in 2016, 'AlphaGo', which was developed by 'Google Deepmind' based on deep learning technique to play the game of Go, was defeated Se-dol Lee who is the World Go champion with score of 4:1. In the point of view that the game of Go is considered as one of the challenging area in machine learning field, it is verified that these new machine learning techniques can perform well, even better than the human being in high-complexity tasks. Previously, most of AI applications in nuclear field were focusing on supporting human operators' tasks such as diagnosis and decision making by rapid classification and prediction, based on fixed training data sets. However, it is expected that AI can be applied to solve more complicated problems (i.e. automation during abnormal states in NPP) by adopting advanced machine learning methodologies. In order to apply the automation system in NPP, firstly it is needed to evaluate the status of the plant quantitatively in real-time, since the information about which state is better (i.e. safe) or worse (i.e. unsafe) is essential for training properly working automation AI. Currently, there are several methodologies for NPP safety evaluation such as probabilistic safety assessment (PSA), safety performance indicator (SPI). However, existing methodologies are not feasible for development of automated system since they are not capable for the cases which are not included in the underlying model, not able to consider delicate changes in the NPP, and hard to evaluate in real-time. Therefore, development of new NPP safety evaluation methodology which can cover previously mentioned requirements is needed to conduct the study on NPP automation further. In this study, the concept of early warning score (EWS) in medical field was adopted to develop the methodology which can evaluate the safety level of the NPP quantitatively and in real-time. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Control Strategies for Distributed Energy Resources to Maximize the Use of Wind Power in Rural Microgrids

The focus of this paper is to design control strategies for distributed energy resources (DERs) to maximize the use of wind power in a rural microgrid. In such a system, it may be economical to harness wind power to reduce the consumption of fossil fuels for electricity production. In this work, we develop control strategies for DERs, including diesel generators, energy storage and demand response, to achieve high penetration of wind energy in a rural microgrid. Combinations of centralized (direct control) and decentralized (autonomous response) control strategies are investigated. Detailed dynamic models for a rural microgrid are built to conduct simulations. The system response to large disturbances and frequency regulation are tested. It is shown that optimal control coordination of DERs can be achieved to maintain system frequency while maximizing wind power usage and reducing the wear and tear on fossil fueled generators.

17 WIND ENERGY↗

Peak Reduction in a Residential Community Through Bayesian Optimization of Transactive Control Signals

Daily residential power consumption in aggregate tends to have a large peak that places stress on the distribution system and induces high operational costs. This work shows that coordinated transactive control of noncritical loads within a residential community or microgrid can help to alleviate peak-time stress on the distribution system by flattening the aggregate load curve. Treating the load forecaster as a high-fidelity, expensive black-box function, a new algorithm utilizing Bayesian optimization (BO) is proposed to achieve the best solution under uncertainty with minimal computing effort. The proposed BO algorithm manipulates the shape of the load based on transactive signals sent to each home. The thermostatically controlled loads (TCLs) act out of self-interest in response to the given price while maintaining comfort, and the optimizer exploits the thermal energy retention of the homes for the benefit of the community. Simulations confirm consistent neighborhood-level peak power reduction and energy cost savings.

Schomer, Ian↗

Influence on Structural Loading of a Wave Energy Converter by Controlling Variable-Geometry Components and the Power Take-Off

Oceans are harsh environments and can impose significant loads on deployed structures. A wave energy converter (WEC) should be designed to maximize the energy absorbed while ensuring the operating wave condition does not exceed the failure limits of the device itself. Therefore, the loads endured by the support structure are a design constraint for the system. Furthermore, the WEC should be adaptable to different sea states. Herethis work uses a WEC-Sim model of a variable-geometry oscillating wave energy converter (VGOSWEC) mounted on a support structure simulated under different wave scenarios. A VGOSWEC resembles a paddle pitching about a fixed hinge perpendicular to the incoming wave fronts. The geometry of the VGOSWEC is varied by opening a series of controllable flaps on the pitching paddle when the structure experiences threshold loads. It is hypothesized that opening the flaps should result in load shedding at the base of the support structure by reducing the moments about the hinge axis. This work compares the hydrodynamic coefficients, natural periods, and response amplitude operators from completely closed to completely open configurations of the controllable flaps. This work shows that the completely open configuration can reduce the pitch and surge loads on the base of the support structure by as much as 80%. Increased loads at the structure’s natural period can be mitigated by an axial power take-off damping acting as an additional design parameter to control the loads at the WEC’s support structure.

16 TIDAL AND WAVE POWER↗

Distributed energy management for community microgrids considering phase balancing and peak shaving

Here, a distributed energy management for community microgrids considering phase balancing and peak shaving is introduced. In each iteration, the house energy management system (HEMS) installed in each house minimises its electricity costs and the costs associated with the discomfort of customers due to deviations in indoor temperature from customers’ set points. At the community level, the microgrid central controller (MCC) schedules the distributed energy resources (DERs) and energy storage based on the received load profiles from customers and the forecast energy price at the point of common coupling. The MCC updates the energy price for each phase based on the amount of unbalanced power between generation and consumption. The updated energy price and unbalanced power for each phase are distributed to the HEMSs on corresponding phases. When the optimisation converges, the unbalanced power of each phase is close to zero. Meanwhile, the schedules of DERs, energy storage systems and the energy consumption of each house are determined by the MCC and HEMSs, separately. Specifically, the phase balancing and peak shaving are considered in the proposed distributed energy management model. The effectiveness of the proposed distributed energy management has been illustrated by case studies.

25 ENERGY STORAGE↗

Robust Stabilization of Inverter-Based Resources Using Virtual Resistance-Based Control

This letter proposes a virtual resistance-based nonlinear control to stabilize and robustify the current layer of inverter-based resources, subject to the grid voltage disturbances, and the grid parameter uncertainties. A class of virtual resistances is proposed and analyzed using concepts from dissipative systems theory. Moreover, specific nonlinear virtual resistance-based controllers are derived, with their corresponding performance analytically bounded. Here, the theoretical and simulation results show that the proposed nonlinear virtual resistance-based controllers significantly reduce the L 2 gain of the closed-loop error system to grid voltage variation and parametric uncertainties. Significant improvements of the transient and steady-state current responses are also demonstrated over linear virtual resistance counterparts.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A HUMAN AUTOMATION INTERACTION CONCEPT FOR A SMALL MODULAR REACTOR CONTROL ROOM

Many advanced nuclear power plant (NPP) designs incorporate higher degrees of automation than the existing fleet of NPPs. Automation is being introduced or proposed in NPPs through a wide variety of systems and technologies, such as advanced displays, computer-based procedures, advanced alarm systems, and computerized operator support systems. Additionally, many new reactor concepts, both full scale and small modular reactors, are proposing increased automation and reduced staffing as part of their concept of operations. However, research consistently finds that there is a fundamental tradeoff between system performance with increased automation and reduced human performance. There is a need to address the question of how to achieve high performance and efficiency of high levels of automation without degrading human performance. One example of a new NPP concept that will utilize greater degrees of automation is the SMR concept from NuScale Power. The NuScale Power design requires 12 modular units to be operated in one single control room, which leads to a need for higher degrees of automation in the control room. Idaho National Laboratory (INL) researchers and NuScale Power human factors and operations staff are working on a collaborative project to address the human performance challenges of increased automation and to determine the principles that lead to optimal performance in highly automated systems. This paper will describe this concept in detail and will describe an experimental test of the concept. The benefits and challenges of the approach will be discussed.

99 GENERAL AND MISCELLANEOUS↗

A deterministic method for PWR loading pattern optimization

A new deterministic approach to core loading optimization is presented. Selection of fuel enrichment and burnable poison (BP) arrangement in a pressurized water reactor (PWR) core are optimally determined subject to power peaking factor (PF) constraints. The deterministic approach is based on the method of Lagrange multipliers and the direct adjoining approach for the inequality power PF constraint. The optimality conditions are derived using calculus of variations resulting in the presence of jump conditions and a linear control Hamiltonian. The optimal control problems are addressed by simultaneously minimizing the Hamiltonian using the gradient method and performing Newton's method in different regions of the core to produce viable solutions for the controls. Without active control of the power profile in PWRs during depletion, our methodology is able to satisfy the power PF constraint at all times by proper loading selection at the beginning of cycle (BOC). This is achieved by promoting the proper burnup path forward in time during the calculation of the forward optimality conditions. Here this information is utilized in the adjoint burnup calculation, which acts to propagate the optimal control path back to the BOC during the calculation of the adjoint optimality conditions. The methodology has been developed into a new code DMCO (Deterministic Multi-Control Optimization) which can produce two-dimensional two-group depletion results in approximately seven minutes per optimization iteration on a personal computer. No application of heuristics is required and the code is capable of finding solutions from initial control distributions. A preliminary case study is presented for the Westinghouse AP600 first cycle fuel loading design which achieved an extended fuel cycle while satisfying power PF constraints.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Optimal Control of Distributed Energy Resources using Model Predictive Control

In an isolated power system (rural microgrid), Distributed Energy Resources (DERs) such as renewable energy resources (wind, solar), energy storage and demand response can be used to complement fossil fueled generators. The uncertainty and variability due to high penetration of wind makes reliable system operations and controls challenging. In this paper, an optimal control strategy is proposed to coordinate energy storage and diesel generators to maximize wind penetration while maintaining system economics and normal operation. The problem is formulated as a multi-objective optimization problem with the goals of minimizing fuel costs and changes in power output of diesel generators, minimizing costs associated with low battery life of energy storage and maintaining system frequency at the nominal operating value. Two control modes are considered for controlling the energy storage to compensate either net load variability or wind variability. Model predictive control (MPC) is used to solve the aforementioned problem and the performance is compared to an open-loop look-ahead dispatch problem. Simulation studies using high and low wind profiles, as well as, different MPC prediction horizons demonstrate the efficacy of the closed-loop MPC in compensating for uncertainties in wind and demand.

Mayhorn, Ebony T.↗

GATE Center of Excellence in Innovative Drivetrains in Electric Automotive Technology Education (IDEATE) (Final Report)

The IDEATE project recognized that this is a critical point in history where advanced engineering solutions are required to propel the U.S. automotive industry irrevocably to the next level: the electrified drivetrain. The existing workforce is not sufficient to this task. It is imperative that automotive engineers with traditional backgrounds focused on internal-combustion and mechanical-drivetrain technologies be retrained with the most current advanced solutions in battery controls and vehicle power electronics. For the long-term success of the U.S. automakers, it is even more important that a future workforce be developed that has both broad and deep comprehension of the issues involved and the most advanced solutions known to these problems. Two campuses of the University of Colorado system joined forces to establish the GATE Center of Excellence in Innovative Drivetrains in Electric Automotive Technology Education (IDEATE). The University of Colorado Boulder (CU-Boulder) is widely regarded as having one of the top graduate programs in power electronics in the country; the University of Colorado Colorado Springs (UCCS) has unrivaled expertise in algorithms for automotive battery control. By collaborating, IDEATE built on our team’s proven strengths to develop innovative curricula and to initiate courses and programs that have provided (and continue to provide) students with a unique opportunity for holistic and specialty education in electric drivetrain technology (part-way through the project, we invited Utah State University to join the project, adding to our strength in power electronics for battery application).

42 ENGINEERING↗

Determination of neutral beam energy fractions from collisional radiative measurements on DIII-D

Neutral beams based on positive ion source technology are a key component of contemporary fusion research. An accurate assessment of the injected beam species mix is important for determining the actual plasma heating and momentum input as well as proper interpretation of beam-based diagnostics. On DIII-D, the main ion charge-exchange spectroscopy system is used to extract well-resolved intensity ratios of the Doppler-shifted D{sub {alpha}} emission from the full, half, and third energy beam components for a variety of beam operational parameters. In conjunction with accurate collisional-radiative modeling, these measurements indicate the assumed species mix and power fractions can vary significantly and should be regularly monitored and updated for the most accurate interpretation of plasma performance. In addition, if stable active control of the power fractions can be achieved through appropriate source tuning, the resulting control over the deposition profile can serve as an additional experimental knob for advanced tokamak studies, e.g., varying the off axis beam current drive without altering the beam trajectory.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A reduced model for the ITER divertor based on SOLPS solutions for ITER Q = 10 baseline conditions: A. identifying options for the control parameters*

Edge codes such as SOLPS coupled to neutral codes such as EIRENE have become so comprehensive and sophisticated that they now constitute, in effect, 'code-experiments' that, as for actual experiments, can benefit from interpretation using simple models and conceptual frameworks, i.e. reduced models. The first task is the identification of options for the reduced model control parameters that are best suited for control of the action of the divertor, i.e. for control of target power loading and sputter-erosion, primarily. A strong correlation between the electron temperature at the divertor target, T e,t , and the neutral deuterium D 2 density at the target, n D2,t , flux-tube resolved, has recently been reported for a number of code studies including SOLPS-4.3 modeling of a set of ~50 ITER baseline cases: Q DT = 10, q 95 = 3, P SOL = 100 MW, metallic walls, and Ne seeding. This part A of the present study reports new results for largely the same ITER cases, confirming the strong correlations reported earlier between local values of T e,t , and (i) n D2,t , and (ii) normalized volumetric losses of power and pressure in the divertor. Strong correlations have now also been found, and are reported here for the first time, between T e,t and all of the divertor target quantities of practical interest. A physical explanation for this surprising result has not been fully identified; nevertheless it has encouraging implications for reduced modeling of the ITER divertor. For such ITER conditions, (i) the global Ne injection rate, Inj Ne [Ne/s], and (ii) the electron temperature at the location on the target where the peak power deposition occurs, T e,t @q ⊥,pk (eV), are found to be promising reduced model control parameters. In the companion report, part B, a reduced model for the ITER divertor is developed and described in detail, based on reversed-direction 2 point modelling, Rev2PM. The input to the reduced model is a value of the variable pair (T et @q ⟂,pk ,Inj Ne ) and the output are values of the various target as well as divertor-entrance quantities of practical interest, e.g. q ⊥,pk , n e,Xpt (the electron density at the poloidal location of the X-point), etc. In part B the reduced model is quantitatively characterized using one half of the code cases; it is then used to successfully predict (replicate) the code values of e.g. n e,Xpt for the other half of the cases.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A reduced model for the ITER divertor based on SOLPS solutions for ITER Q = 10 baseline conditions: B. A reduced model based on reversed-direction two point modeling

Edge codes such as SOLPS coupled to neutral codes such as EIRENE have become so comprehensive and sophisticated that they now constitute, in effect, 'code-experiments' that, as for actual experiments, can benefit from interpretation using simple models and conceptual frameworks, i.e. reduced models. The first task is the identification of options for the reduced model control parameters that are best suited for control of the action of the divertor, i.e. for control of target power loading and sputter–erosion, primarily. A strong correlation between the electron temperature at the divertor target, T e,t , and the neutral deuterium D 2 density at the target, n D2,t , flux-tube resolved, has recently been reported for a number of code studies including SOLPS-4.3 modeling of a set of ~50 ITER baseline cases: Q DT = 10, q 95 = 3, P SOL = 100 MW, metallic walls, and Ne seeding (Pitts et al 2019). Part A of the present study reports new results for largely the same ITER cases, confirming the strong correlation reported earlier between local values of T e,t , and (i) n D2,t , and (ii) normalized volumetric losses of power and pressure in the divertor. Strong correlations have now also been found, and are reported here for the first time, between T e,t and all of the divertor target quantities of practical interest. A physical explanation for this surprising result has not as yet been fully identified; nevertheless it has encouraging implications for reduced modeling of the ITER divertor. For such ITER conditions, (i) the global Ne injection rate, Inj Ne (Ne s –1 ), and (ii) the electron temperature at the location on the target where the peak power deposition occurs, T e,t @q ⊥,pk (eV), are found to be promising reduced model control parameters. In this part B, a reduced model for the ITER divertor is developed and described in detail, based on reversed-direction two point modeling, Rev2PM. The input to the reduced model is a value of the variable pair (T e,t @q ⊥,pk , Inj Ne )for a chosen case and the output are values of the various target as well as divertor-entrance quantities of practical interest, e.g. q ⊥,pk , the electron density at the X-point, n e,Xpt , etc. The reduced model was quantitatively characterized using one half of the code cases; it was then used to successfully predict (replicate) the code values of e.g. n e,Xpt for the other half.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Enhanced dynamic contingency analysis for power systems

The present disclosure describes systems and techniques that enhance effectiveness and efficiency of a contingency analysis tool that is used for studying the magnitude and likelihood of extreme contingencies and potential cascading events across a power system. The described systems and techniques include deploying the contingency analysis tool in a high-performance computing (HPC) environment and incorporating visual situational awareness approaches to allow power system engineers to quickly and efficiently evaluate multiple power system simulation models. Furthermore, the described systems and techniques include the power system contingency-analysis tool calculating and coordinating protection element settings, as well as assessing controls of the power system using small-signal nomograms, allowing power system engineers to more effectively comprehend, evaluate, and analyze causes and effects of cascading events against a topology of a power system.

Samaan, Nader A.↗

Technoeconomic Design Optimization for Fast Reactors. Part II: Impact of Technoeconomic Constraints on Optimal Design

There is a current drive toward optimizing reactors, particularly small/micro reactors to minimize cost and maximize performance. Previous work has investigated the development of technoeconomic workflows for the design optimization of pool-type fast reactors that aim to deploy into district energy grids. Initial scoping studies verified that the workflow was capable of capturing design trends throughout a variety of design configurations and problem formulations while remaining sufficiently flexible. In this paper, this methodology is applied to understand how cost functions and technoeconomic constraints can drive optimal reactor design. Specifically, the UPu10Zr-fueled fast reactor model from Part I is adapted to include changes in the fissile content limits, control rod worth limits, control rod drive cost, and assumed fuel form. In the case of constraint relaxation at fixed power (fissile content and control rod worth limits), cost sensitivities of 5% to 10% were uncovered. Multi-objective optimization at varying reactor power levels with individualized control rod drives for each assembly (as opposed to one operational and one safety drive) increased cost by $\$10$ to $\$25$ million and substantially altered the optimal core geometry, favoring geometries with substantially fewer control rod placements relative to baseline optimization. Finally, a multi-objective optimization was performed at varying power levels with the fuel form overhauled to metallic, high-assay low-enriched uranium–based U10Zr with more refined fuel cost models. In the case of uranium fueling, the costs increased by at least $50 million relative to the baseline case. Furthermore, economic fuel zoning and lower reactivity swing cores were recovered. Each case serves to demonstrate the value of applying technoeconomic workflows to initial reactor design scoping studies to better understand the trade-off for a proposed concept between different design options.

Argonne Reactor Computation (ARC) codes↗

Advanced Sensors & Controls FWP Overview

Fossil energy power generation is needed now and in the future, but its role is shifting from baseload operation to fulfilling dispatchable power needs in regions of the United States. Novel sensors and controls will help to increase efficiency, minimize emissions, and reduce operating costs of existing power generation technologies under this increased load following role; and help enable next generation power systems with high efficiency and greater operational flexibility.<br>

Buric, Michael↗

Stimulated Generation of Magnetrons powered below the Self-Excitation Threshold Voltage

Modern CW or pulsed superconducting accelerators of megawatts beams require efficient RF sources controllable in phase and power. It is desirable to have an individual RF power source with power up to hundreds of kW for each Superconductive RF (SRF) cavity. For pulsed accelerators the pulse duration in millisecond range is required. The efficiency of the traditional RF sources (klystrons, IOTs, solid-state amplifiers) in comparison to magnetrons is lower and the cost of unit of RF power is significantly higher. Typically, the cost of RF sources and their operation is a significant part of the total project cost and operation. The magnetron-based RF sources with a cost of power unit of 1-3 dollars per Watt would significantly reduce the capital and operation costs in comparison with the traditional RF sources. This arouses interest in magnetron RF sources for use in modern accelerators. A recently developed kinetic model describing the principle of magnetron operation and subsequent experiments resulted in an innovative technique producing the "stimulated" generation of magnetrons powered below the self-excitation threshold voltage. The magnetron operation in this regime is stable, low noise, controllable in phase and power, and provides higher efficiency than other types of RF power sources. It allows operation in CW and pulse modes (at large duty factor). For pulsed operation this technique does not require pulse modulators to form RF pulses. It also looks as a promising opportunity to extend magnetron life time. The developed technique, its experimental verification and a brief explanation of the kinetic model substantiating the technique are presented and discussed in this article.

43 PARTICLE ACCELERATORS↗