Search NASA⌕ Search

SEARCH · Search NASA

Results for “Power Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

Tests of Low-Noise MMIC Amplifier Module at 290 to 340 GHz

A document presents data from tests of a low-noise amplifier module operating in the frequency range from 290 to 340 GHz said to be the highest-frequency low-noise, solid-state amplifier ever developed. The module comprised a three-stage monolithic microwave integrated circuit (MMIC) amplifier integrated with radial probe MMIC/waveguide transitions and contained in a compact waveguide package, all according to the concepts described in the immediately preceding article and in the referenced prior article, "Integrated Radial Probe Transition From MMIC to Waveguide" (NPO-43957), NASA Tech Briefs Vol. 31, No. 5 (May 2007), page 38. The tests included measurements by the Y-factor method, in which noise figures are measured repeatedly with an input noise source alternating between an "on" (hot-load) condition and an "off" (cold-load) condition. (The Y factor is defined as the ratio between the "on" and "off" noise power levels.) The test results showed that, among other things, the module exhibited a minimum noise figure of about 8.7 dB at 325 GHz and that the gain at that frequency under the bias conditions that produced the minimum noise figure was between about 9 and 10 dB.

Gaier, Todd↗

Performance of a Thermally Stable Polyaromatic Hydrocarbon in a Simulated Concentrating Solar Power Loop

Polyaromatic hydrocarbon thermal fluids showing thermally stability to 600 C have been tested for solar thermal-power applications. Although static thermal tests showed promising results for 1-phenylnaphthalene, loop testing at temperatures to 450 C indicated that the fluid isomerized and degraded at a slow rate. In a loop with a temperature high enough to drive the isomerization, the higher melting point byproducts tended to condense onto cooler surfaces. So, as experienced in loop operation, eventually the internal channels of cooler components in trough solar electric generating systems, such as the waste heat rejection exchanger, may become coated or clogged affecting loop performance. Thus, pure 1-phenylnaphthalene, without addition of stabilizers, does not appear to be a fluid that would have a sufficiently long lifetime (years to decades) to be used in a loop at the temperatures greater than 500 C. The performance of a concentrating solar loop using high temperature fluids was modeled based on the National Renewable Laboratory Solar Advisory Model. It was determined that a solar-to-electricity efficiency of up to 30% and a capacity factor of near 60% could be achieved using a high efficiency collector and 12 h thermal energy storage.

concentrating solar power↗

Design of a millimeter-wave polarimeter for NSTX-Upgrade and initial test on DIII-D

Polarimetry is a powerful diagnostic technique to probe plasma equilibria and magnetic fluctuations in fusion plasmas. In a high beta plasma such as the National Spherical Torus eXperiment (NSTX), these measurements are important to understand plasma stability and anomalous transport. A 288 GHz polarimeter operating along a major radial chord in retroreflection geometry has been developed and is being tested on the DIII-D tokamak to prepare for future implementation on NSTX-Upgrade. The system launches a rotating linearly polarized beam and detects the phase shift directly related to the polarization change caused by the plasma. To accomplish this, a pair of orthogonal linearly polarized beams with a stable difference frequency is generated using a single sideband modulation technique, then combined and transformed to be counter-rotating circularly polarized. To improve phase resolution, quasi-optical isolation, using Faraday rotators and polarizers, is utilized to eliminate a multi-path feedback effect, which is found to be the primary source of phase error. The bench tests in the laboratory and DIII-D power supply test discharges indicate {<=}1 Degree-Sign phase resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Joint US/Russian testing for track propagation

The power thresholds below which track propagation does not occur were determined in Russian spacecraft. The tests were performed in air and vacuum with direct current on different insulation and sample configurations. The examined wire insulations included 100 percent polyimide, modified polyimide-based insulations containing 7 to 8 percent and 100 percent polytetrafluoroethylene. The wires were tested in configurations consisting of seven-wire bundles. The results indicated that the track propagation thresholds were lower in vacuum than in air.

Hirsch, David↗

Predictability of Brayton electric power system performance

Data from the first tests of the 2- to 15-kilowatt space power system in a vacuum chamber were compared with predictions of both a pretest analysis and a modified version of that analysis. The pretest analysis predicted test results with differences of no more than 9 percent of the largest measured value for each quantity. The modified analysis correlated measurements. Differences in conversion efficiency and power output were no greater than plus or minus 2.5 percent. This modified analysis was used to project space performance maps for the current test system.

Klann, J. L.↗

CMB power spectrum parameter degeneracies in the era of precision cosmology

Cosmological parameter constraints from the CMB power spectra alone suffer several well-known degeneracies. These degeneracies can be broken by numerical artefacts and also a variety of physical effects that become quantitatively important with high-accuracy data e.g. from the Planck satellite. We study degeneracies in models with flat and non-flat spatial sections, non-trivial dark energy and massive neutrinos, and investigate the importance of various physical degeneracy-breaking effects. We test the CAMB power spectrum code for numerical accuracy, and demonstrate that the numerical calculations are accurate enough for degeneracies to be broken mainly by true physical effects (the integrated Sachs-Wolfe effect, CMB lensing and geometrical and other effects through recombination) rather than numerical artefacts. We quantify the impact of CMB lensing on the power spectra, which inevitably provides degeneracy-breaking information even without using information in the non-Gaussianity. Finally we check the numerical accuracy of sample-based parameter constraints using CAMB and COSMOMC. In an appendix we document recent changes to CAMB's numerical treatment of massive neutrino perturbations, which are tested along with other recent improvements by our degeneracy exploration results.

79 ASTRONOMY AND ASTROPHYSICS↗

FY13 Annual Report:APEEM Components Analysis and Evaluation

The objectives of this evaluation is to Support the evaluation of current and proposed electric machine and power electronics technologies in a vehicle context to understand the applicability of a particular powertrain technology to a given vehicle and to determine areas/regions for component design improvement based upon system usage patterns; and Enhance the current benchmarking and prototype evaluation capabilities of DOE APEEM programs with the addition of transient-capable testing facilities for power electronics and electric machinery components.

33 ADVANCED PROPULSION SYSTEMS↗

The design and analysis of single flank transmission error tester for loaded gears

To strengthen the understanding of gear transmission error and to verify mathematical models which predict them, a test stand that will measure the transmission error of gear pairs under design loads has been investigated. While most transmission error testers have been used to test gear pairs under unloaded conditions, the goal of this report was to design and perform dynamic analysis of a unique tester with the capability of measuring the transmission error of gears under load. This test stand will have the capability to continuously load a gear pair at torques up to 16,000 in-lb at shaft speeds from 0 to 5 rpm. Error measurement will be accomplished with high resolution optical encoders and the accompanying signal processing unit from an existing unloaded transmission error tester. Input power to the test gear box will be supplied by a dc torque motor while the load will be applied with a similar torque motor. A dual input, dual output control system will regulate the speed and torque of the system. This control system's accuracy and dynamic response were analyzed and it was determined that proportional plus derivative speed control is needed in order to provide the precisely constant torque necessary for error-free measurement.

Bassett, Duane E.↗

Model Design and Pre-Test CFD Analysis for a Supersonic Retropropulsion Wind Tunnel Test

Future Mars human lander missions will require using powered descent beginning at supersonic conditions, something which has never been done before at Mars. Significant aerosciences challenges exist due to interactions between the retrorocket exhaust plumes and the freestream flow that alter the aerodynamic behavior of the powered descent vehicle. Historically, wind tunnel tests have been used to study supersonic retropropulsion with inert gas exhaust simulants. Also, SpaceX has successfully decelerated the Falcon 9 first stage numerous times by using powered flight at supersonic conditions. On the computational side, Reynolds-Averaged Navier-Stokes flowfield simulations are regularly completed at full-scale conditions. However, the available ground and flight data do not provide a basis for calibrating the computational uncertainties for aerodynamic interference forces and moments on proposed Mars descent vehicles, either because of insufficient data or dissimilar vehicles geometries and/or conditions. Thus, additional ground testing is needed to continue addressing the aerosciences risks for large-scale human Mars landers. To that end, a retropropulsion wind tunnel test will be conducted in the NASA Langley Unitary Plan Wind Tunnel in 2020. The test is designed to improve upon similar past tests, both in terms of model design and measured data. The test campaign will use subscale model geometries derived from the two current NASA powered descent reference vehicles: a blunt low lift-to-drag vehicle and a more slender geometry. This paper covers the reference vehicles, test objectives, model design, scaling parameters, test matrix, and computational analysis to date.

Karl T Edquist↗

Consistency relation and non-Gaussianity in a Galileon inflation

We study a particular Galileon inflation in the light of Planck2015 observational data in order to constraint the model parameter space. We study the spectrum of the primordial modes of the density perturbations by expanding the action up to the second order in perturbations. Then we pursue by expanding the action up to the third order and find the three point correlation functions to find the amplitude of the non-Gaussianity of the primordial perturbations in this setup. We study the amplitude of the non-Gaussianity both in equilateral and orthogonal configurations and test the model with recent observational data. Our analysis shows that for some ranges of the non-minimal coupling parameter, the model is consistent with observation and it is also possible to have large non-Gaussianity which would be observable by future improvements in experiments. Moreover, we obtain the tilt of the tensor power spectrum and test the standard inflationary consistency relation ( r = −8 n {sub T} ) against the latest bounds from the Planck2015 dataset. We find a slight deviation from the standard consistency relation in this setup. Nevertheless, such a deviation seems not to be sufficiently remarkable to be detected confidently.

79 ASTRONOMY AND ASTROPHYSICS↗

Investigation of upper-surface-blowing nacelle integration at cruise speeds utilizing powered engine simulators

Various overwing nacelle designs were investigated on a representative four engine short haul aircraft configuration during a combined analytical and experimental program. Design conditions were M sub o = 0.7 and C sub L = 0.4. All nacelles had D shaped nozzle exits and included a streamline contoured design, a low boattail angle reference configuration, and a high boattail angle powered lift design. Testing was done with the design four engine airplane configuration as well as with only inboard nacelles installed. Turbopowered engine simulators were used to provide realistic representation of nacelle flows. Performance trends are compared for the various nacelle designs. In addition, comparisons are presented between analytical and experimental pressure distributions and between flow through and powered simulator results.

Meleason, E. T.↗

CALiPER Report 22.1: Photoelectric Performance of LED MR16 Lamps

This report is a follow-up to CALiPER Application Summary Report 22, which investigated the photometric performance of LED MR16 lamps. The initial report found that many of the LED MR16 lamps did not perform as required by ENERGY STAR based on their equivalency claims, although they generally did provide substantial efficacy advantages compared to halogen MR16 lamps. All testing was completed using laboratory power supplies, with all but one product tested at 12 V AC. In contrast, this report examined the photoelectric performance of the same set of lamps, using commercially available transformers and dimmers as well as laboratory power supplies providing both AC and DC power.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

TEAMER: Twin Ocean Power Wave Energy Converter Comprehensive Overview

These files collectively provide a comprehensive overview of the testing process, data analysis, and validation for the Twin Ocean Power device tested at the O.H. Hinsdale Wave Research Laboratory, supported by TEAMER funding. This resource includes an overview of power results for a series of 7 trials. The files included in this comprehensive overview include a comprehensive log sheet for each trial, a summary of all trials, and processing scripts for the raw data. It includes all raw data in .tsv and MATLAB compatible formats, an average power chart, angular velocity charts for each trial, trial metrics, and power output files. This resource includes images of the Twin Ocean Power Wave Energy Converter device components and movement during testing and video recordings of each trial.

16 TIDAL AND WAVE POWER↗

Power Measurement Errors on a Utility Aircraft

Extensive flight test data obtained from two recent performance tests of a UH 60A aircraft are reviewed. A power difference is calculated from the power balance equation and is used to examine power measurement errors. It is shown that the baseline measurement errors are highly non-Gaussian in their frequency distribution and are therefore influenced by additional, unquantified variables. Linear regression is used to examine the influence of other variables and it is shown that a substantial portion of the variance depends upon measurements of atmospheric parameters. Correcting for temperature dependence, although reducing the variance in the measurement errors, still leaves unquantified effects. Examination of the power difference over individual test runs indicates significant errors from drift, although it is unclear how these may be corrected. In an idealized case, where the drift is correctable, it is shown that the power measurement errors are significantly reduced and the error distribution is Gaussian. A new flight test program is recommended that will quantify the thermal environment for all torque measurements on the UH 60. Subsequently, the torque measurement systems will be recalibrated based on the measured thermal environment and a new power measurement assessment performed.

Bousman, William G.↗

Local Power Impact Experiment Design for a New Fuel Type for use in the Advanced Test Reactor

The Advanced Test Reactor (ATR), and complimentary zero-power ATR Critical (ATRC) reactor, located at Idaho National Labs (INL), are undergoing conversion from Highly Enriched Uranium (HEU) to Low Enriched Uranium (LEU). Both have a variety of testing locations that can receive large variations in flux due to its unique serpentine design, consisting of five lobes (see Figure 1). Initial criticality and power distribution throughout the core are controlled by core-external outer shim control cylinders (OSCCs). Distinct test loops allow for testing at specific temperatures, pressures, and irradiation conditions. The ATR is one of the key nuclear engineering research and testing facilities within the DOE National Laboratory Complex, and the ATRC supports its operation [1]. Currently, the Office of Material Management and Minimization (M3) within the National Nuclear Security Administration of the DOE is working to convert the remaining research reactors, including the ATR, from 93% HEU fuel to 19.75% LEU fuel (LEU) to support non-proliferation [2]. Extensive materials testing at INL and internationally has demonstrated that a high-density uranium molybdenum (U 10Mo) alloy can meet the performance requirements of the remaining high powered research reactors. However, there are many technical challenges to address before the conversion to LEU can be successful, including the accurate characterization of the reactor core physics with LEU fuel. Reactor physics safety evaluations currently use Monte Carlo for the 21st Century (MC21), a continuous-energy Monte Carlo radiation transport code [3]. Existing MC21 models of the ATR and ATRC cores have a validation basis for use in neutronics analyses with HEU fuel. The models are used to support safety analyses that include comparisons to the safety requirements for the reactors. However, the use of the LOWE element in the ATR and ATRC is not currently covered by the current model validation basis. To deploy the new fuel type, extensive computational reactor physics support is necessary to support the use of LOWE in the ATR and ATRC. Therefore, LOWE requires a rigorous validation basis, aligned with that of HEU fuel, that takes advantage of the existing software tools and processes currently used for the ATR and ATRC. The experiment to validate of the MC21 models for determining power, the Power Impact Validation Experiment, will consist of two flux runs in the ATRC, one with fully HEU loading and one with a single LOWE element. Both flux runs will be instrumented with 20 sets of azimuthal fission wires and 3 sets of axial fission wires, as shown in Figure 4. Standard flux run methodology will be used [4]. Power Impact Validation Experiment data will be compared against MC21 calculated data, both for absolute fission rate accuracy and to determine the relative change in fission rates between the two runs. The results of the Power Impact Validation Experiment and subsequent evaluations will provide the validation basis for MC21 for use with LOWE elements. Key features of the Power Impact Validation Experiment include: (1) Two flux runs to allow for LOWE perturbed measurements to be compared to already validated measurements taken from a full core of HEU fuel, (2) Optimization of instrumentation to balance analytical needs with practical considerations (e.g., limited time window to count beta particles from fission products), and (3) Standard ATRC core loading, including both driver positions and flux traps, to minimize cost while remaining representative of typical ATR core loading.

42 ENGINEERING↗

The Biolink Implantable Telemetry System

Most biotelemetry applications deal with the moderated data rates of biological signals. Few people have studied the problem of transcutaneous data transmission at the rates required by NASA's Life Sciences-Advanced BioTelemetry System (LS-ABTS). Implanted telemetry eliminate the problems associated with wire breaking the skin, and permits experiments with awake and unrestrained subjects. Our goal is to build a low-power 174-216MHz Radio Frequency (RF) transmitter suitable for short range biosensor and implantable use. The BioLink Implantable Telemetry System (BITS) is composed of three major units: an Analog Data Module (ADM), a Telemetry Transmitter Module (TTM), and a Command Receiver Module (CRM). BioLink incorporates novel low-power techniques to implement a monolithic digital RF transmitter operating at 100kbps, using quadrature phase shift keying (QPSK) modulation in the 174-216MHz ISM band. As the ADM will be specific for each application, we focused on solving the problems associated with a monolithic implementation of the TTM and CRM, and this is the emphasis of this report. A system architecture based on a Frequency-Locked Loop (FLL) Frequency Synthesizer is presented, and a novel differential frequency that eliminates the need for a frequency divider is also shown. A self sizing phase modulation scheme suitable for low power implementation was also developed. A full system-level simulation of the FLL was performed and loop filter parameters were determined. The implantable antenna has been designed, simulated and constructed. An implant package compatible with the ABTS requirements is also being proposed. Extensive work performed at 200MHz in 0.5um complementary metal oxide semiconductors (CMOS) showed the feasibility of integrating the RF transmitter circuits in a single chip. The Hajimiri phase noise model was used to optimize the Voltage Controlled Oscillator (VCO) for minimum power consumption. Two test chips were fabricated in a 0.5pm, 3V CMOS process. Measured phase noise for a 1.5mW, 200MHz ring oscillator VCO is -80dBc/Hz at 100KHZ offset, showing good agreement with the theory. We also propose a novel superregenerative receiver architecture for implementing the command receiver. The superregenerative receiver's simplicity, low cost, and low power consumption has made it the receiver of choice for short-distance data communications, remote control and home automation. We present the design of a superregenerative AM receiver implemented in a 0.5um CMOS technology that operates at 433.92MHz and dissipates only 300uW. Further work entails detailed transistor-level design of the FLL and superregenerative receiver and a monolithic implementation of an implantable transceiver in 0.5um CMOS technology.

Betancourt-Zamora, Rafael J.↗

High-Power Krypton Hall Thruster Technology Being Developed for Nuclear-Powered Applications

The NASA Glenn Research Center has been performing research and development of moderate specific impulse, xenon-fueled, high-power Hall thrusters for potential solar electric propulsion applications. These applications include Mars missions, reusable tugs for low-Earth-orbit to geosynchronous-Earth-orbit transportation, and missions that require transportation to libration points. This research and development effort resulted in the design and fabrication of the NASA-457M Hall thruster that has been tested at input powers up to 95 kW. During project year 2003, NASA established Project Prometheus to develop technology in the areas of nuclear power and propulsion, which are enabling for deep-space science missions. One of the Project-Prometheus-sponsored Nuclear Propulsion Research tasks is to investigate alternate propellants for high-power Hall thruster electric propulsion. The motivation for alternate propellants includes the disadvantageous cost and availability of xenon propellant for extremely large scale, xenon-fueled propulsion systems and the potential system performance benefits of using alternate propellants. The alternate propellant krypton was investigated because of its low cost relative to xenon. Krypton propellant also has potential performance benefits for deep-space missions because the theoretical specific impulse for a given voltage is 20 percent higher than for xenon because of krypton's lower molecular weight. During project year 2003, the performance of the high-power NASA-457M Hall thruster was measured using krypton as the propellant at power levels ranging from 6.4 to 72.5 kW. The thrust produced ranged from 0.3 to 2.5 N at a discharge specific impulse up to 4500 sec.

Jacobson, David T.↗