Search NASA⌕ Search

SEARCH · Search NASA

Results for “RADIATION DOSES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

Phase I-II Trial of Concurrent Capecitabine and Oxaliplatin With Preoperative Intensity-Modulated Radiotherapy in Patients With Locally Advanced Rectal Cancer

Purpose: To identify the maximal tolerated dose level of preoperative intensity-modulated radiotherapy combined with capecitabine and oxaliplatin and to evaluate the efficacy. Patients and Methods: Patients with rectal T3-T4 and/or N0-N+ rectal cancer received capecitabine 825 mg/m{sup 2} twice daily Monday through Friday and oxaliplatin 60 mg/m{sup 2} intravenously on Days 1, 8, and 15, concurrently with intensity-modulated radiotherapy. The radiation dose was increased in 5.0-Gy steps in cohorts of 3 patients starting from 37.5 Gy in 15 fractions (dose level [DL] 1). DL2 and DL3 were designed to reach 42.5 Gy in 17 fractions and 47.5 Gy in 19 fractions, respectively. Results: No dose-limiting toxicity was observed at DL1 or DL2. Of the 3 patients treated at DL3, 1 presented with Grade 3 diarrhea, which was considered a dose-limiting toxicity, and 3 additional patients were added. Of the 6 patients treated at DL3, no new dose-limiting toxicities were observed, and DL3 was identified as the recommended dose in this study. Eight additional patients were treated at 47.5 Gy. Grade 2 proctitis was the most frequent adverse event (40%); Grade 3 diarrhea occurred in 2 patients (10%). All patients underwent surgery, and 17 patients (85%) underwent R0 resection. Four patients (20%) presented with a histologic response of Grade 4, 11 (55%) with Grade 3+, 2 (15%) with Grade 3, and 2 patients (10%) with Grade 2. Conclusion: The maximal tolerated dose in this study was 47.5 Gy. The high rates of pathologic response of Grade 3+ and 4 must be confirmed through the accrual of new patients in the Phase II study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Technical and Imaging Outcomes from the UK Registry of Prostate Artery Embolization (UK-ROPE) Study: Focusing on Predictors of Clinical Success

Introduction: The UK Registry of Prostate Artery Embolization (UK-ROPE) was a prospective, multicentre study comparing PAE against surgical therapies for symptomatic benign prostatic hyperplasia (BPH). A wealth of data was collected supplementary to the main study outcomes which provide a snapshot of UK PAE practice. We aimed to interpret these data in the hope of providing insight into factors which affect clinical outcome and radiation dose. Methods: 216 patients (mean age 66, mean IPSS 21.3) undergoing PAE at 20 British centres from July 2014 to January 2016 were prospectively followed up to 12 months with retrospective analysis of the data. Technical outcome was evaluated based on procedural and fluoroscopy times, skin dose and dose area product (DAP). Clinical outcome was evaluated through collection of Qmax, IPSS reduction and prostate volume reduction. Multiple analysis of variance (MANOVA) was used to assess the significance of various patients and procedural factors on clinical outcome and patient dose. Results: Significant predictors of technical outcome which affected patient skin dose included severity of CTA-detected atheroma (p < 0.001), the practitioner (p < 0.001) and use of protective coil embolization (p = 0.019). Predictors of clinical outcome included initial prostate size (dichotomized into groups > 80 ml and = <80 ml, d = 1, p = 0.0138), embolic agent (spherical particles < 300 nm performed best, p = 0.01) and number of arteries embolized (IPSS reduction of 32.9% in unilateral PAE versus 54.4% for bilateral PAE, p = 0.026). Conclusion: We have identified several important factors which are associated with improved clinical outcome and increased patient dose which we hope will facilitate optimal patient selection and encourage improved embolization technique.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Statistical characteristics of streak artifacts on CT images: Relationship between streak artifacts and mA s values

The purpose of this study is to investigate how streak artifacts on computed tomography (CT) images vary with reduction in radiation doses by assessing the quantitative relationship between the streak artifacts and milliampere-time product (mA s) values. A commercially available chest phantom was used to measure the streak artifacts on the CT images obtained using a 4- and 16-multidetector-row helical CT scanners with various mA s values at a constant tube voltage of 120 kVp. The cardiac slice image was employed as a target image for evaluating the streak artifacts on the CT image. Eighty parallel line segments with a length of 20 pixels were placed perpendicular to numerous streak artifacts on the cardiac slice image, and the largest difference between adjacent CT values in each of the 80 CT-value profiles of these line segments was employed as a feature variable of streak artifacts; these feature variables have been analyzed by the extreme value theory. The largest difference between adjacent CT values in each CT-value profile can be statistically modeled by a Gumbel distribution. Further, the maximum level of streak artifacts on CT images that will be tolerated for clinical use and low-dose CT screening examination was expected to be estimated using the location parameter in the Gumbel distribution.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

WE-FG-207B-01: BEST IN PHYSICS (IMAGING): Abdominal CT with Three K-Edge Contrast Materials Using a Whole-Body Photon-Counting Scanner: Initial Results of a Large Animal Experiment

Purpose: To demonstrate the feasibility of in vivo three-material decomposition techniques using photon-counting CT (PCCT) with possible advantage of resolving arterial and venous flow of an organ simultaneously. Methods: Abdominal PCCT scans were acquired using a prototype whole-body PCCT with four energy thresholds (25/50/75/90keV) in a canine. Bismuth subsalicylate (60 mg) was administered orally one day prior to scanning. Immediately prior to CT scan, gadoteric acid (60 ml, Dotarem, Guerbet) was intravenously injected, followed in ten minutes by a 20mL injection of iodinated contrast (iopamidol 370 mg/mL, Bracco). Scans were acquired every ∼20 seconds, starting from the time of iodine injection. Linear material decomposition was performed using the least mean squares method to create concentration maps of iodine, gadolinium, and bismuth. The method was calibrated to vials with known concentrations of materials placed next to the animal. The accuracy of this method was tested on vials with known concentrations. Results: The material decomposition algorithm’s accuracy was confirmed to be within ±4mM in the test vials. In the animal, we could estimate the concentration of gadolinium in delayed-enhanced phase (10 minutes post-injection) in the abdomen. We could follow the wash-in and wash-out of iodine in arterial, venous, and excretory flow of the kidneys (20s, 80s, and 120s post-iodine injection) while gadolinium was present in the delayed-enhanced phase. Bismuth, which was used as a contrast agent for the gastro-intestinal tract, was easily differentiable from the other two contrast agents in the small intestine. Conclusion: This study shows the feasibility of using photon-counting CT with four energy thresholds to differentiate three k-edge contrast agents in vivo. This can potentially reduce radiation dose to patients by combining arterial and venous phases into a single acquisition.

60 APPLIED LIFE SCIENCES↗

A rapid noninvasive characterization of CT x-ray sources

Purpose: The aim of this study is to generate spatially varying half value layers (HVLs) that can be used to construct virtual equivalent source models of computed tomography (CT) x-ray sources for use in Monte Carlo CT dose computations. Methods: To measure the spatially varying HVLs, the authors combined a cylindrical HVL measurement technique with the characterization of bowtie filter relative attenuation (COBRA) geometry. An apparatus given the name “HVL Jig” was fabricated to accurately position a real-time dosimeter off-isocenter while surrounded by concentric cylindrical aluminum filters (CAFs). In this geometry, each projection of the rotating x-ray tube is filtered by an identical amount of high-purity (type 1100 H-14) aluminum while the stationary radiation dose probe records an air kerma rate versus time waveform. The CAFs were progressively nested to acquire exposure data at increasing filtrations to calculate the HVL. Using this dose waveform and known setup geometry, each timestamp was related to its corresponding fan angle. Data were acquired using axial CT protocols (i.e., rotating tube and stationary patient table) at energies of 80, 100, and 120 kVp on a single CT scanner. These measurements were validated against the more laborious conventional step-and-shoot approach (stationary x-ray tube). Results: At each energy, HVL data points from the COBRA-cylinder technique were fit to a trendline and compared with the conventional approach. The average relative difference in HVL between the two techniques was 1.3%. There was a systematic overestimation in HVL due to scatter contamination. Conclusions: The described method is a novel, rapid, accurate, and noninvasive approach that allows one to acquire the spatially varying fluence and HVL data using a single experimental setup in a minimum of three scans. These measurements can be used to characterize the CT beam in terms of the angle-dependent fluence and energy spectra along the bowtie filter direction, which can serve as input for accurate CT dose computations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Long-Term Outcomes of Patients With Spinal Cord Gliomas Treated by Modern Conformal Radiation Techniques

Purpose: This study retrospectively examines the long-term therapeutic outcomes of 32 patients with primary spinal cord gliomas at Massachusetts General Hospital between 1991 and 2005 treated by either photon intensity-modulated radiotherapy or conformal proton radiotherapy. Methods and Materials: Individual patient tumor types included 14 ependymomas, 17 astrocytomas, and one oligodendroglioma. Twenty-two patients were treated with photon beam radiation therapy, and 10 patients were treated with proton beam therapy. The overall survival and time to progression were analyzed. Average radiation dose for patients was 51 Gy in 1.8 median daily fractions over 29 treatments. Results: For all 32 patients, the overall 5-year survival was 65% and the progression-free survival was 61%, respectively. Overall survival was significantly worse for patients more than 55 years of age (p = 0.02). Ependymoma patients had significantly longer survival times than astrocytoma patients (p = 0.05). Patients who had undergone a biopsy developed worse outcomes then those with a resection (p = 0.05). With the caveat of a limited number of patients, the multivariate model seems to suggest improved overall survival for younger patients (<54 years of age), ependymoma histology, and photon vs. proton treatment. Conclusion: For patients with spinal cord gliomas, significant factors associated with patient outcome include tumor pathology, age, extent of surgery, and treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Association of Neuronal Injury in the Genu and Body of Corpus Callosum After Cranial Irradiation in Children With Impaired Cognitive Control: A Prospective Study

Brain radiation is associated with functional deficits in children. The purpose of this study was to examine white matter integrity as measured by diffusion tensor imaging and associations with region-specific radiation dose and neuropsychological functioning in children treated with cranial irradiation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Natural Radiation from Soil using Gamma-Ray Spectrometry

We have studied the distribution of natural radioactivity in the soil of Interlagos, in Sao Paulo city and Billings Reservoir, in Sao Bernardo do Campo, Sao Paulo, Brazil. The main contribution of the effective radiation dose is due to the elements of the {sup 238}Th decay series, with smaller contributions from {sup 40}K and the elements of the series of {sup 238}U. The results indicate the dose in all of the studied areas is around the average international dose due to external exposure to gamma rays (0.48 mSv/yr) proceeding from natural terrestrial elements.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dosimetry tools and techniques for IMRT

Intensity modulated radiation therapy (IMRT) poses a number of challenges for properly measuring commissioning data and quality assurance (QA) radiation dose distributions. This report provides a comprehensive overview of how dosimeters, phantoms, and dose distribution analysis techniques should be used to support the commissioning and quality assurance requirements of an IMRT program. The proper applications of each dosimeter are described along with the limitations of each system. Point detectors, arrays, film, and electronic portal imagers are discussed with respect to their proper use, along with potential applications of 3D dosimetry. Regardless of the IMRT technique utilized, some situations require the use of multiple detectors for the acquisition of accurate commissioning data. The overall goal of this task group report is to provide a document that aids the physicist in the proper selection and use of the dosimetry tools available for IMRT QA and to provide a resource for physicists that describes dosimetry measurement techniques for purposes of IMRT commissioning and measurement-based characterization or verification of IMRT treatment plans. This report is not intended to provide a comprehensive review of commissioning and QA procedures for IMRT. Instead, this report focuses on the aspects of metrology, particularly the practical aspects of measurements that are unique to IMRT. The metrology of IMRT concerns the application of measurement instruments and their suitability, calibration, and quality control of measurements. Each of the dosimetry measurement tools has limitations that need to be considered when incorporating them into a commissioning process or a comprehensive QA program. For example, routine quality assurance procedures require the use of robust field dosimetry systems. These often exhibit limitations with respect to spatial resolution or energy response and need to themselves be commissioned against more established dosimeters. A chain of dosimeters, from secondary standards to field instruments, is established to assure the quantitative nature of the tests. This report is intended to describe the characteristics of the components of these systems; dosimeters, phantoms, and dose evaluation algorithms. This work is the report of AAPM Task Group 120.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-130: Dosimetric Evaluation of Tissue Equivalent Gel Dosimeter Using Saccharide in Radiotherapy System

Purpose: In this study, the dose responses of the MAGIC gel with various concentrations and type of saccharide are examined to clarify the roles of mono and disaccharide in the polymerization process. Then we focused on the tissue equivalence and dose sensitivity of MAGIC gel dosimeters. Methods: The gel is composed of HPLC, 8% gelatin, 2 × 10-3 M L-ascorbic acid, 1.8 × 10-2 M hydroquinone, 8 × 10-5 M copper(II)sulfate and 9% methacrylic acid, new polymer gels are synthesized by adding glucose(monosaccharide), sucrose(disaccharide) and urea in the concentration range of 5∼35%. For irradiation of the gel, cesium-137 gamma-ray irradiator was used, radiation dose was delivered from 5∼50 Gy. MRI images of the gel were acquired by using a 3.0 T MRI system. Results: When saccharide and urea were added, the O/C, O/N and C/N ratios agreed with those of soft tissue with 1.7%. The dose-response of glucose and sucrose gel have slope-to-intercept ratio of 0.044 and 0.283 respectively. The slope-to-ratio is one important determinant of gel sensitivity. R-square values of glucose and sucrose gel dosimeters were 0.984 and 0.994 respectively. Moreover when urea were added, the slope-to-intercept ratio is 0.044 and 0.073 respectively. R-square values of mono and disaccharide gel were 0.973 and 0.989 respectively. When a saccharide is added into the MAGIC gel dosimeter, dose sensitivity is increased. However when urea were added, dose sensitivity is slightly decreased. Conclusion: In this study, it was possible to obtain the following conclusions by looking at the dose response characteristics after adding mono-, di-saccharide and urea to a MAGIC gel dosimeter. Saccharide was a tendency of increasing dose sensitivity with disaccharide. Sa.ccharide is cost effective, safe, soft tissue equivalent, and can be used under various experimental conditions, making it a suitable dosimeter for some radiotherapy applications.

60 APPLIED LIFE SCIENCES↗

Low-dose dual-isotope procedure planed for myocardial perfusion CZT-SPECT and assessed through a head-to-head comparison with a conventional single-isotope protocol

Purpose of the report: This study aimed at assessing an original low-dose dual-isotope procedure in which the abnormal stress Tc-99m Sestamibi SPECT is followed by rest Tl-201 SPECT, along with a head-to-head comparison with a single-isotope procedure. Methods and results: One hundred two patients, referred for a low-dose stress-SPECT with Sestamibi (123 ± 20 MBq) on a CZT camera and for whom a rest Sestamibi SPECT was warranted, had an additional Tl-201 rest-SPECT (52 ± 5 MBq) between stress and rest Sestamibi SPECT recordings. Tl-201 images were processed for spill-over and scatter corrections, and uptake differences with stress Sestamibi SPECT were analyzed: (1) for rest acquisitions from Tl-201 (dual-isotope procedure) and from Sestamibi (single-isotope procedure) and (2) in segments for which a diagnosis of ischemia, infarct, or normal perfusion was achieved. Mean effective dose was 8.3 mSv for dual-isotope but would decrease to 5.7 mSv for an expected rate of 37% of patients for whom rest-SPECT is not warranted. After a further background correction of Tl-201 images, the rest–stress difference in myocardial uptake was equivalent between dual- and single-procedures for identifying ischemic segments (respective areas-under-curves: 0.83 ± 0.03 and 0.81 ± 0.03). Conclusion: This original dual-isotope procedure provides acceptable radiation doses and consistent results, as compared with conventional single-isotope.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Study of Natural Radiation Distribution in Soil of Sao Bernardo do Campo

We have studied the distribution of natural radioactivity in the soil of five sites of the city Sao Bernardo do Campo, Sao Paulo, Brazil. The main contribution of the radiation dose is due to the isotope {sup 40}K, with smaller contributions from the elements of the series of {sup 238}U and {sup 232}Th. The results indicate the dose in all of the studied areas is around the average international dose due to external exposure to gamma rays (0.48 mSv/yr) proceeding from natural terrestrial elements.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Sci-Thur PM – Colourful Interactions: Highlights 03: Radiation induced glycogen accumulation in non-small cell lung cancer xenografts detected using Raman spectroscopy

Purpose: This study presents the novel application of Raman spectroscopy (RS) to identify biochemical signatures of radiation response in human non-small cell lung cancer (NSCLC) xenografts, irradiated in vivo. Methods: Human NSCLC cells (H460) were subcutaneously injected into the flanks of 12 mice. Tumours were treated with single fraction radiation doses (0, 5 or 15 Gy) and harvested at 3 days post irradiation. A Renishaw inVia Raman microscope coupled to a 785 nm laser was used to collect Raman spectral maps for each tumour. Immunohistochemistry (IHC) staining for CAIX was used to visualize hypoxia, and co-registration between IHC fluorescence and Raman images was carried out. Results: Principal component analysis revealed radiation induced spectral signatures linked to changes in protein, nucleic acid, lipid and carbohydrates. In particular, a marked increase in glycogen for irradiated tumours was observed. Spatial mapping revealed intra-tumoural heterogeneity in the distribution of glycogen within the tumour, suggesting tumour response to radiation is not globally uniform. Furthermore, co-registration of Raman glycogen maps with CAIX IHC staining showed a correlation between glycogen rich and hypoxic regions of the tissue. Conclusions: We identify glycogen as a unique radiation induced response in NSCLC tumour xenografts, which may reflect inherent metabolic changes associated with radiation response in tissue. This study provides unique insight into the biochemical response of tumours, irradiated in vivo, and demonstrates the potential of RS for detecting radiobiological responses in tumours.

60 APPLIED LIFE SCIENCES↗

Characteristic performance evaluation of a photon counting Si strip detector for low dose spectral breast CT imaging

Purpose: The possible clinical applications which can be performed using a newly developed detector depend on the detector's characteristic performance in a number of metrics including the dynamic range, resolution, uniformity, and stability. The authors have evaluated a prototype energy resolved fast photon counting x-ray detector based on a silicon (Si) strip sensor used in an edge-on geometry with an application specific integrated circuit to record the number of x-rays and their energies at high flux and fast frame rates. The investigated detector was integrated with a dedicated breast spectral computed tomography (CT) system to make use of the detector's high spatial and energy resolution and low noise performance under conditions suitable for clinical breast imaging. The aim of this article is to investigate the intrinsic characteristics of the detector, in terms of maximum output count rate, spatial and energy resolution, and noise performance of the imaging system. Methods: The maximum output count rate was obtained with a 50 W x-ray tube with a maximum continuous output of 50 kVp at 1.0 mA. A{sup 109}Cd source, with a characteristic x-ray peak at 22 keV from Ag, was used to measure the energy resolution of the detector. The axial plane modulation transfer function (MTF) was measured using a 67 μm diameter tungsten wire. The two-dimensional (2D) noise power spectrum (NPS) was measured using flat field images and noise equivalent quanta (NEQ) were calculated using the MTF and NPS results. The image quality parameters were studied as a function of various radiation doses and reconstruction filters. The one-dimensional (1D) NPS was used to investigate the effect of electronic noise elimination by varying the minimum energy threshold. Results: A maximum output count rate of 100 million counts per second per square millimeter (cps/mm{sup 2}) has been obtained (1 million cps per 100 × 100 μm pixel). The electrical noise floor was less than 4 keV. The energy resolution measured with the 22 keV photons from a {sup 109}Cd source was less than 9%. A reduction of image noise was shown in all the spatial frequencies in 1D NPS as a result of the elimination of the electronic noise. The spatial resolution was measured just above 5 line pairs per mm (lp/mm) where 10% of MTF corresponded to 5.4 mm{sup −1}. The 2D NPS and NEQ shows a low noise floor and a linear dependence on dose. The reconstruction filter choice affected both of the MTF and NPS results, but had a weak effect on the NEQ. Conclusions: The prototype energy resolved photon counting Si strip detector can offer superior imaging performance for dedicated breast CT as compared to a conventional energy-integrating detector due to its high output count rate, high spatial and energy resolution, and low noise characteristics, which are essential characteristics for spectral breast CT imaging.

60 APPLIED LIFE SCIENCES↗

The Results of Surgery, With or Without Radiotherapy, for Primary Spinal Myxopapillary Ependymoma: A Retrospective Study From the Rare Cancer Network

Purpose: The aim of this study was to assess the outcome of patients with primary spinal myxopapillary ependymoma (MPE). Materials and Methods: Data from a series of 85 (35 females, 50 males) patients with spinal MPE were collected in this retrospective multicenter study. Thirty-eight (45%) underwent surgery only and 47 (55%) received postoperative radiotherapy (RT). Median administered radiation dose was 50.4 Gy (range, 22.2-59.4). Median follow-up of the surviving patients was 60.0 months (range, 0.2-316.6). Results: The 5-year progression-free survival (PFS) was 50.4% and 74.8% for surgery only and surgery with postoperative low- (<50.4 Gy) or high-dose ({>=}50.4 Gy) RT, respectively. Treatment failure was observed in 24 (28%) patients. Fifteen patients presented treatment failure at the primary site only, whereas 2 and 1 patients presented with brain and distant spinal failure only. Three and 2 patients with local failure presented with concomitant spinal distant seeding and brain failure, respectively. One patient failed simultaneously in the brain and spine. Age greater than 36 years (p = 0.01), absence of neurologic symptoms at diagnosis (p = 0.01), tumor size {>=}25 mm (p = 0.04), and postoperative high-dose RT (p = 0.05) were variables predictive of improved PFS on univariate analysis. In multivariate analysis, only postoperative high-dose RT was independent predictors of PFS (p = 0.04). Conclusions: The observed pattern of failure was mainly local, but one fifth of the patients presented with a concomitant spinal or brain component. Postoperative high-dose RT appears to significantly reduce the rate of tumor progression.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Experimental validation of a three-dimensional linear system model for breast tomosynthesis

A three-dimensional (3D) linear model for digital breast tomosynthesis (DBT) was developed to investigate the effects of different imaging system parameters on the reconstructed image quality. In the present work, experimental validation of the model was performed on a prototype DBT system equipped with an amorphous selenium (a-Se) digital mammography detector and filtered backprojection (FBP) reconstruction methods. The detector can be operated in either full resolution with 85 {mu}m pixel size or 2x1 pixel binning mode to reduce acquisition time. Twenty-five projection images were acquired with a nominal angular range of {+-}20 deg. The images were reconstructed using a slice thickness of 1 mm with 0.085x0.085 mm in-plane pixel dimension. The imaging performance was characterized by spatial frequency-dependent parameters including a 3D noise power spectrum (NPS) and in-plane modulation transfer function (MTF). Scatter-free uniform x-ray images were acquired at four different exposure levels for noise analysis. An aluminum (Al) edge phantom with 0.2 mm thickness was imaged to measure the in-plane presampling MTF. The measured in-plane MTF and 3D NPS were both in good agreement with the model. The dependence of DBT image quality on reconstruction filters was investigated. It was found that the slice thickness (ST) filter, a Hanning window to limit the high-frequency components in the slice thickness direction, reduces noise aliasing and improves 3D DQE. An ACR phantom was imaged to investigate the effects of angular range and detector operational modes on reconstructed image quality. It was found that increasing the angular range improves the MTF at low frequencies, resulting in better detection of large-area, low-contrast mass lesions in the phantom. There is a trade-off between noise and resolution for pixel binning and full resolution modes, and the choice of detector mode will depend on radiation dose and the targeted lesion.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Force balancing in mammographic compression

Purpose: In mammography, the height of the image receptor is adjusted to the patient before compressing the breast. An inadequate height setting can result in an imbalance between the forces applied by the image receptor and the paddle, causing the clamped breast to be pushed up or down relative to the body during compression. This leads to unnecessary stretching of the skin and other tissues around the breast, which can make the imaging procedure more painful for the patient. The goal of this study was to implement a method to measure and minimize the force imbalance, and to assess its feasibility as an objective and reproducible method of setting the image receptor height. Methods: A trial was conducted consisting of 13 craniocaudal mammographic compressions on a silicone breast phantom, each with the image receptor positioned at a different height. The image receptor height was varied over a range of 12 cm. In each compression, the force exerted by the compression paddle was increased up to 140 N in steps of 10 N. In addition to the paddle force, the authors measured the force exerted by the image receptor and the reaction force exerted on the patient body by the ground. The trial was repeated 8 times, with the phantom remounted at a slightly different orientation and position between the trials. Results: For a given paddle force, the obtained results showed that there is always exactly one image receptor height that leads to a balance of the forces on the breast. For the breast phantom, deviating from this specific height increased the force imbalance by 9.4 ± 1.9 N/cm (6.7%) for 140 N paddle force, and by 7.1 ± 1.6 N/cm (17.8%) for 40 N paddle force. The results also show that in situations where the force exerted by the image receptor is not measured, the craniocaudal force imbalance can still be determined by positioning the patient on a weighing scale and observing the changes in displayed weight during the procedure. Conclusions: In mammographic breast compression, even small changes in the image receptor height can lead to a severe imbalance of the applied forces. This may make the procedure more painful than necessary and, in case the image receptor is set too low, may lead to image quality issues and increased radiation dose due to undercompression. In practice, these effects can be reduced by monitoring the force imbalance and actively adjusting the position of the image receptor throughout the compression.

61 RADIATION PROTECTION AND DOSIMETRY↗