Search NASA⌕ Search

SEARCH · Search NASA

Results for “Scanning techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

A study of model deflection measurement techniques applicable within the national transonic facility

Moire contouring, scanning interferometry, and holographic contouring were examined to determine their practicality and potential to meet performance requirements for a model deflection sensor. The system envisioned is to be nonintrusive, and is to be capable of mapping or contouring the surface of a 1-meter by 1-meter model with a resolution of 50 to 100 points. The available literature was surveyed, and computations and analyses were performed to establish specific performance requirements, as well as the capabilities and limitations of such a sensor within the geometry of the NTF section test section. Of the three systems examined, holographic contouring offers the most promise. Unlike Moire, it is not hampered by limited contour spacing and extraneous fringes. Its transverse resolution can far exceed the limited point sampling resolution of scanning heterodyne interferometry. The availability of the ruby laser as a high power, pulsed, multiple wavelength source makes such a system feasible within the NTF.

Hildebrand, B. P.↗

Nondestructive Evaluation of the Gimbal Joint Flowliner Slots in the Space Shuttle Main Propulsion System Hydrogen Feedline

Fatigue cracks were discovered in the STS-112 Liquid Hydrogen Feedline flowliners in 2002. This led to a development program aimed at providing nondestructive evaluation methods and techniques to verify the existence of these types of cracks in oval shaped slots cut into the ends of the feedlines above the bellows joints. These slots were used to improve flow dynamics and to facilitate cleaning in the bellow joint region. These types of fatigue cracks posed a possible metal debris ingestion threat for the Space Shuttle Main Engines, which attached to these particular joints. Results of this program produced three reliable inspection techniques utilizing the imaging of replisets with a Scanning Electron microscope, eddy current, and ultrasound. The program developed unique probes and fixtures and in the case of eddy current and ultrasound, provided qualification and certification of the particular techniques by various Design of Experiments and Probability of Detection studies utilizing multiple inspectors.

Suits, Michael W.↗

Super-resolution for scanning light stimulation systems

Super-resolution (SR) is a technique used in digital image processing to overcome the resolution limitation of imaging systems. In this process, a single high resolution image is reconstructed from multiple low resolution images. SR is commonly used for CCD and CMOS (Complementary Metal-Oxide-Semiconductor) sensor images, as well as for medical applications, e.g., magnetic resonance imaging. Here, we demonstrate that super-resolution can be applied with scanning light stimulation (LS) systems, which are common to obtain space-resolved electro-optical parameters of a sample. For our purposes, the Projection Onto Convex Sets (POCS) was chosen and modified to suit the needs of LS systems. To demonstrate the SR adaption, an Optical Beam Induced Current (OBIC) LS system was used. The POCS algorithm was optimized by means of OBIC short circuit current measurements on a multicrystalline solar cell, resulting in a mean square error reduction of up to 61% and improved image quality.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Revised radiometric calibration technique for LANDSAT-4 Thematic Mapper data by the Canada Centre for Remote Sensing

Observations of raw image data, raw radiometric calibration data, and background measurements extracted from the raw data streams on high density tape reveal major shortcomings in a technique proposed by the Canadian Center for Remote Sensing in 1982 for the radiometric correction of TM data. Results are presented which correlate measurements of the DC background with variations in both image data background and calibration samples. The effect on both raw data and data corrected using the earlier proposed technique is explained and the correction required for these factors as a function of individual scan line number for each detector is described. How the revised technique can be incorporated into an operational environment is demonstrated.

Murphy, J.↗

Visual scanning behavior

This report summarizes the results and knowledge of scan behavior gained in various simulation and laboratory studies. Results were obtained through various analysis techniques such as real-time viewing of the pilot's scanning behavior and quantitative analysis of scan behavior performance parameters (average dwell time, dwell percentages, instrument transition paths, dwell histograms, and entropy rate measures). Pilot scan behavior is discussed in the following areas; scanning is a subconscious conditioned activity, scanning is situation dependent, pilots' scanning pattern is centered around a home base. Scanning behavior data have been shown to be useful in determining pilot's workload, evaluating pilot's strategy and role, determining the rate of information transfer of various displays, and aiding in pilot training.

Harris, R. L., Sr.↗

Visual scanning behavior

This report summarizes the results and knowledge of scan behavior gained in various simulation and laboratory studies. Results were obtained through various analysis techniques such as real-time viewing of the pilot's scanning behavior and quantitative analysis of scan behavior performance parameters (average dwell time, dwell percentages, instrument transition paths, dwell percentages, instrument transition paths, dwell histograms, and entropy rate measures). Pilot scan behavior is discussed in the following areas; scanning is a subconscious conditioned activity, scanning is situation dependent, pilots' scanning pattern is centered around a home base. Scanning behavior data nave been shown to be useful in determining pilot's workload, evaluating pilot's strategy and role, determining the rate of information transfer of various displays, and aiding in pilot training.

Harris, R. L., Sr.↗

First 14-Layer Twinned Hexagonal Perovskite Ba 14 Mn 1.75 Ta 10.5 O 42 : Atomic-Scale Imaging of Cation Ordering

Formation of hexagonal perovskite with mixed cubic and hexagonal stacking of AO 3 layers becomes more and more difficult when the number of layers in the stacking repeating unit increases. So far, the highest number of layers reported for twinned hexagonal perovskite is 12, with alternative 5 consecutive cubic layers and one hexagonal layer in the (ccccch) 2 sequence. Here, we present the unexpected formation of a 14-layer twinned hexagonal perovskite with a stacking sequence (cccccch) 2 for the BaO 3 layers on the Ba 14 Mn 1.75 Ta 10.5 O 42 (Ba 8 MnTa 6 O 24 ) composition, the first example of twinned hexagonal perovskite with a periodicity exceeding 12-layers. The B-cation and vacancy distributions are characterized by multiple efficient and complementary techniques including neutron and synchrotron powder diffraction, scanning transmission electron microscopy-high angle annular dark field (STEM-HAADF) imaging, and electron energy loss spectroscopy (EELS) and X-ray energy dispersive spectroscopy (EDS) elemental mapping. Atomic-resolution STEM-HAADF imaging and EELS/EDS elemental mapping enables direct observation of high-spin d 5 Mn 2+ cation ordering in the d 0 Ta 5+ host, thus demonstrating the great potential of this technique for probing cation ordering and performing structure determination. Moreover, atomic mapping allows for the observation of local defect structure variants, which can be a powerful tool for future new material design. The large high-spin Mn 2+ cation and Ta-vacancy pair formation in face-sharing octahedral sites play key roles on both the stabilization of this 14-layer twinned hexagonal perovskite structure and the Mn 2+ ordering in the central corner-sharing octahedral (CSO) positions within the five-consecutive CSO layers. Here, compared with the 8-layer twinned Ba 8 ZnTa 6 O 24 material, the low quality factor in microwave frequency and enhanced ultraviolet and visible light absorption of Ba 14 Mn 1.75 Ta 10.5 O 42 as well as the photocatalytic activity on water splitting are discussed in terms of the presence of high-spin Mn 2+ cations in the structure.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Advanced monitoring concepts

The emphasis in initial work will be on application of image processing techniques in the site monitoring of an ILS glide slope transmitting array. The glide slope requires a clear area in front of the antennas for use as a reflecting zone. Reflecting or scattering obstacles in this area can cause incorrect path formation and system outages. Direct video monitoring is impractical due to the narrow band nature of communication links from the ILS site to the regional maintenance location. Slow scan video is possible, but even this technique may require transmission of large amounts of data, tying up remote monitoring lines. The steps used to minimize data transmission are listed.

Lilley, Robert W.↗

Intraarterial Ultrasound in Pancreatic Cancer: Feasibility Study and Preliminary Results

Despite technological advances in computed tomography (CT) and magnetic resonance imaging, the involvement of the celiac or mesenteric artery in pancreatic cancer remains uncertain in many cases. Infiltration of these vessels is important in making decisions about therapy choices but often can only be definitively determined through laparotomy. Local (intraarterial) ultrasound may increase diagnostic accuracy. Using the Volcano intravascular ultrasound (IVUS) system, we applied a transfemoral method to scan the celiac and mesenteric arteries directly intraarterial. This technique was used in five patients with suspected pancreatic cancer. Technical success was achieved in all cases. In one case, a short dissection of the mesenteric artery occurred but could be managed interventionally. In tumors that did not contact with the vessels, IVUS was unable to display the tissue pathology. Our main interest was the infiltration of the arteries. In one case, infiltration was certain in the CT scan but uncertain in two patients. In the latter two cases, IVUS correctly predicted infiltration in one and freedom from tumor in the other case. In our preliminary study, IVUS correctly predicted arterial infiltration in all cases. IVUS did not provide new information when the tumor was far away from the vessel. Compared with IVUS in the portal vein, the information about the artery is more detailed, and the vessel approach is easier. These results encouraged us to design a prospective study to evaluate the sensitivity and specificity of this method.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Nanoimaging and Nanospectroscopy of Polaritons with Time Resolved s ‐SNOM

Abstract The development of electronics and photonics is entering a new era of ultrahigh speed sensing, data processing, and telecommunication. The carrier frequencies of the next‐generation electronic devices inevitably extend beyond radio frequencies, marching toward the nominally photonics‐dominated territories, e.g., terahertz and beyond. As a result, electronic and photonic techniques naturally merge and seek common ground. At the forefront of this technical trend is the field of polaritonics, where polaritons are half‐light, half‐matter quasiparticles that carry the properties of both “bare” photons and “bare” dipole‐carrying excitations. The Janus‐faced nature of polaritons renders the unique capability of operando control using photoexcitation or applied electric field. Here, state‐of‐the‐art ultrafast polaritonic phenomena probed by scattering‐type scanning near‐field optical microscope ( s ‐SNOM) techniques is reviewed. The ultrafast dynamical control and loss‐reduction of the polariton propagation are discussed with special emphasis on the creation and probing of the tip or edge induced plasmon– and phonon–polaritons in low‐dimensional systems. The detailed technical aspects of s ‐SNOM and its possible future development are also presented.

Yao, Ziheng↗

Material Profile Influences in Bulk-Heterojunctions

he morphology in mixed bulk-heterojunction films are compared using three different quantitative measurement techniques. We compare the vertical composition changes using high-angle annular dark-field scanning transmission electron microscopy with electron tomography and neutron and x-ray reflectometry. The three measurement techniques yield qualita-tively comparable vertical concentration measurements. The presence of a metal cathode during thermal annealing is observed to alter the fullerene concentration throughout the thickness of the film for all measurements. However, the abso-lute vertical concentration of fullerene is quantitatively different for the three measurements. The origin of the quantitative measurement differences is discussed. The authors thank Luna Innovations, Inc. for donating the endohedral fullerenes used in this study and Plextronics for the P3HT. They are gratefully thank the National Science Foundation Energy for Sustainability Program, Award No. 0933435. This work benefited from the use of the Lujan Neutron Scattering Center at Los Alamos Neutron Science Center funded by the DOE Office of Basic Energy Sciences and Los Alamos National Laboratory under DOE Contract DE-AC52-06NA25396. This research was also supported in part by Laboratory Directed Research & Development program at PNNL. The Pacific Northwest National Laboratory is operated by Battelle for the US Department of Energy under contract DE-AC05-76RL01830.

blends↗

Study to determine the aquatic biological effects on the Solid Rocket Booster (SRB)

The surface of the reusable solid rocket boosters (SRB), which are jettisoned from the Shuttle Orbiter to parachute in the sea, are studied for colonization by marine life. Techniques for monitoring the marine microbial fouling of SRB materials are presented. An assessment of the nature and degree of the biofouling expected on the SRB materials in the recovery zone is reported. A determination of the degree and the effects of seasonal variation occurring on microbial fouling in the retrieval zone waters is made. The susceptibility of the SRB parachute recovery system to microbial fouling and biodeterioration is investigated. The development of scanning electron microscopy and epifluorescence microscopic observation techniques for rapid assessment of microbial fouling is discussed.

Colwell, R. R.↗

Microstructure Characterization of Fiber Laser Welds of S690QL High-Strength Steels

The use of fiber laser welding to join S690QL steels has attracted interest in the field of construction and assembly. Herein, 13-mm-thick S690QL welded joints were obtained without filler materials using the fiber laser. The as-welded microstructures and the impact energies of the joints were characterized and measured using electron microscopy in conjunction with high-resolution transmission electron images, X-ray diffraction, and impact tests. The results indicated that a single-sided welding technique could be used to join S690QL steels up to a thickness of 12 mm (fail to fuse the joint in the root) when the laser power is equal to 12 kW (scan speed 1 m/min). Double-side welding technique allows better weld penetration and better control of heat distribution. Observation of the samples showed that the fusion zone exhibited bainitic and martensitic microstructures with increased amounts of martensites (Ms) compared with the base materials. Also, the grains in the fusion zone increased in coarseness as the heat input was increased. The fusion zone exhibited increased hardness (397 HV{sub 0.2}) while exhibiting a simultaneous decrease in the impact toughness. The maximum impact energy value of 26 J was obtained from the single-side-welded sample, which is greater than those obtained from the double-side-welded samples (maximum of 18 J). Many more dislocations and plastic deformations were found in the fusion zone than the heat-affected zone in the joint, which hardened the joints and lowered the impact toughness. The microstructures characterized by FTEM–energy-dispersive X-ray spectrometer also exhibited laths of M, as well as stacking faults and dislocations featuring high-density, interfacial structure ledges that occur between the high-angle grain boundaries and the M and bainite.

36 MATERIALS SCIENCE↗

Experimental comparison of two hot-wire techniques for resolution of turbulent mass flux and local stagnation temperature in supersonic flow

The performance of two constant-temperature normal hot-wire techniques in a supersonic flow is examined. The first technique uses a single-wire and rapid scanning of multiple overheat ratios. Time averages of the signals at all overheats are used to separate the mean and rms mass flux, stagnation temperature and their cross-correlation. The second technique uses a dual-wire probe with each wire operating at different overheat ratios, giving instantaneous mass flux and stagnation temperature. Preliminary results indicate that the separation distance (0.18 mm) between the two hot wires in the dual-wire probe does not introduce significant error. However, the rms mass flux inferred from the dual-wire technique is a factor of two higher than that from the single-wire technique.

Walker, D. A.↗

Regular Scanning Tunneling Microscope Tips can be Intrinsically Chiral

We report our discovery that regular scanning tunneling microscope tips can themselves be chiral. This chirality leads to differences in electron tunneling efficiencies through left- and right-handed molecules, and, when using the tip to electrically excite molecular rotation, large differences in rotation rate were observed which correlated with molecular chirality. As scanning tunneling microscopy is a widely used technique, this result may have unforeseen consequences for the measurement of asymmetric surface phenomena in a variety of important fields.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Depth Thermography: Noninvasive 3D Temperature Profiling Using Infrared Thermal Emission

Here, we introduce a technique based on infrared thermal emission, termed depth thermography, that can remotely measure the temperature distribution beneath the surface of certain objects. Depth thermography utilizes the thermal-emission spectrum in the semitransparent spectral region of the target object to extract its temperature as a function of depth, in contrast with conventional thermography, which uses the spectrally integrated thermally emitted power to measure the surface temperature. Coupled with two-dimensional imaging, for example using an infrared hyperspectral camera or scanning a single-pixel spectrometer, this technique can yield volumetric temperature distributions. Furthermore, we carried out a proof-of-concept experiment on an asymmetrically heated fused-silica window, extracting the temperature distribution throughout the sample. Depth thermography may enable noncontact volumetric temperature measurements of microscopic objects such as multilayer electronic devices or macroscopic volumes of liquids and gases, as well as simultaneous all-optical measurements of optical and thermal properties of materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗