Search NASA⌕ Search

SEARCH · Search NASA

Results for “System Reliability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

Advantages and applications of megawatt-sized heat-pipe reactors

Recently, worldwide interest in nuclear energy has focused on small reactors (10 to 300 MWe) to address emerging energy needs in remote locations. These designs are new to varying degrees but share similar approaches and common weaknesses with regard to primary heat rejection that differ little from reactor designs of the late 1950's. Here, an innovative concept, heat-pipe reactors, is discussed. The concept is unique in its simplicity and potential for safe, affordable, and reliable energy. Given the potential for reactors to meet worldwide energy needs and the pivotal role of heat rejection in overall reactor safety, the potential societal impact of this type of innovation is substantial. Heat-pipe-cooled, fast-spectrum reactors have been proposed for government applications requiring a robust, reliable, remotely controlled system with capacity much less than 1 MWe; however, they have not been designed for power ranges greater than 1 MWe. Los Alamos National Laboratory has initiated a study to design heat-pipe-cooled, fast-fission reactors and to generate a point design of a > 10-MWe-class machine suitable for next-generation compact reactors at remote locations. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Performance Evaluation of an Intelligent Sensor Platform for Radiation Monitoring Applications

Accurate, rugged, and reliable radiation detection systems are important for area and environmental monitoring applications. The desire for spectroscopic capability has increased in monitoring aspects of the nuclear fuel cycle to provide fast characterization of the radiation profile of a situation, such as the planned or unplanned release of material. The reduction or elimination of having to conduct sampling for laboratory analysis can result in significant cost savings for an industry, government agency, or regulatory body. A new system, comprised of a NaI:Tl scintillator and a G-M tube, has been designed and tested, taking into account the following end-user requirements: ease-of-use, capability to network and supervise multiple units, compact form factor, low power consumption, versatility, and stability. The detector sizes were selected to accommodate a dose rate up to 1 Sv/hr. Several algorithms and analysis routines have been developed to incorporate these key needs without sacrificing on accuracy, dynamic range, nuclide identification, and sensitivity. This presentation will introduce the major hardware and software components of the platform, as well as the user interface and data analysis workflow. Key features of the hardware include an environmentally robust housing, low power signal processing electronics, patented LED-based gain stabilization, and an embedded processor for unattended instrument management and data analysis. New and improved algorithms for determining scintillator gamma dose rates, total integrated dose, and nuclide identification will be introduced. The two detector elements were modeled with MCNP and validated experimentally. The results of the radiological testing shall be presented including energy resolution, throughput, dose response, and minimum detectable activities. The dose response has been evaluated in simulations and with measurements to ensure accurate response with respect to energy spectrum of the dose field and direction of the incident radiation. Spectroscopy evaluations, such as nuclide detection probability and false alarm rates, were performed and comparisons to existing algorithms shall also be presented. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tangible Solutions for Grid Operation Upgrade

Many countries worldwide are setting clean energy targets to decarbonize the energy sector and add higher wind and solar capacities. Given their distributed nature, variable renewable energy (VRE) assets can have unique grid integration considerations, and require grid operation practices to be modernized. When transitioning to higher renewable energy levels, many system operators configure a dedicated renewable energy desk to manage renewable energy resource operation in the system control center. Further, system operation planning is conducted with VRE and load forecasting to enable reliable real-time system operation. NREL has partnered with many system operators in the region to identify appropriate technology and grid modernization solutions. NREL and partners from system operators in the region will present on the challenges and some solutions that have been applied and share best practices such as energy management system upgrades, VRE forecasting framework, grid flexibility improvements, and staff training.

emerging economies↗

A Fully Decentralized Modulation Scheme for Modular Multilevel Converters

As the number of submodules rapidly increase, control architecture of Modular Multilevel Converters (MMCs) is transforming from centralized to distributed in order to address the challenges of tremendous computational burden and massive wiring. In this digest, we propose a modulation scheme for the MMCs with distributed controls, where each submodule is able to handle both controls and modulation in a decentralized manner. It enables the distributed controllers to synchronize in terms of fast-switching pulse width modulation (PWM). Aiming at this key technical challenge, this research develops a physics-informed PWM control strategy of mirroring the spontaneous synchronization feature of coupled oscillator’s behavior at switching frequency. Thanks to less reliance on wirings and communications, the proposed approach has the potential of i) improving reliability of MMC systems, and ii) reducing cost and space requirements for MMCs. The proposed approach has been preliminarily verified through a simulation tool for power electronics systems.

Lu, Minghui [BATTELLE (PACIFIC NW LAB)]↗

Rooftop Unit (RTU) Maintenance Guide

The commercial buildings industry has long emphasized affordability, energy efficiency, and useful service life in rooftop unit (RTU) equipment. The trade-offs between these characteristics can impact decisions about the initial cost of equipment and ongoing operating costs. Often, the desire for lower initial costs leads to adoption of low-efficiency systems or neglect of proper maintenance in the interest of short-term cost savings. Maintenance of these systems is a critical step to ensure system efficiency and reliability, low operating costs, and a reasonable payback period. This guide is intended for facility managers who own or are interested in purchasing and installing RTUs and need to familiarize themselves with the maintenance requirements. This resource contains best practices, important considerations, and additional information related to commercial RTU equipment, but does not replace manufacturer-specific instructions.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Design and Analysis of a 25 MWe Supercritical CO2 Turbo Machine

This paper presents the design and analysis of a turbo machine operating with supercritical carbon dioxide (sCO2) in a 25 MWe Recompression Brayton Cycle (RCBC). The work was performed under US Department of Energy (DoE) program DE-EE-0010318. The design process involves the aerodynamic design of the compressor and turbine, including the initial layout of flowpaths and stage configurations to achieve high efficiency and performance. Additionally, a comprehensive rotodynamic analysis is performed to ensure the stability and reliability of the system. Conceptual designs for a high-speed motor and synchronous generator that match turbomachinery requirements are also developed from first principles.

42 ENGINEERING↗

Quantification Of Margins And Uncertainties: A Bayesian Approach (full Paper)

Quantification of Margins and Uncertainties (QMU) is 'a formalism for dealing with the reliability of complex technical systems, and the confidence which can be placed in estimates of that reliability.' (Eardleyet al, 2005). In this paper, we show how QMU may be interpreted in the framework of Bayesian statistical inference, using a probabilistic network. The Bayesian approach clarifies the probabilistic underpinnings of the formalism, and shows how the formalism can be used for deciSion-making.

99 GENERAL AND MISCELLANEOUS↗

Datasets for Widespread Residential Space Heating Electrification in Texas

In this experiment, we explore long term patterns in electricity demand driven by the dual effects of full electrification of space heating in Texas (by adoption of electric heat pumps), and climate change. We use a predictive model of electricity demand, climate projections, and an open source nodal power system (DC Optimal Power Flow) model of the Electric Reliability Council of Texas (ERCOT) system. Heat pumps are a more energy efficient way of providing space heating and cooling in homes. We attempt to exhaustively investigate the impacts of full residential space heating electrification by adoption of heat pumps for the segment of Texas households that currently rely on fossil fuels (about 40%), while simultaneously incorporating climate change meteorological variables. We explore a range of scenarios of heat pump efficiency and climate uncertainty over a long period of future years (2020-2099). In total, the simulation experiment generates 1,280 simulation years of hourly data. We report and analyze results in form of impacts on residential load, total load, peak load, seasonality of peaking, and reliability measured by occurrence and frequency of loss of load events. While the experiment is for ERCOT, the insights and approach can be applied to other regions. The results from the analysis can inform system planners on a range of potential capacity requirements/ reliability implications and/or risks of full space heating electrification via the adoption of electric heat pumps, given the uncertainty in the scenarios/ climate futures. The dataset includes model output for residential, non residential and total load, and the results from the GO ERCOT model runs for 4 RCP Scenarios (RCP 4.5 Cooler, RCP 4.5 Hotter, RCP 8.5 Cooler, RCP 8.5 Hotter), 4 Heating electrification Scenarios (Base , Standard Efficiency HP, High Efficiency HP, Ultra-High Efficiency HP) over 80 years (2020-2099). The metrological variables at BA scale were weighted weighted using population projections consistent with the SSP3 scenario.

Climate Change↗

Ubiquitous Power Electronics in Future Power Systems: Recommendations to fully utilize fast control capabilities

Power electronics is becoming ubiquitous in power systems because the rapid growth of variable renewable generation such as wind and solar, responsive load, electric vehicles, energy storage, as well as DC transmission. As a result, a high percentage of electricity will be generated, transmitted or consumed by power electronics in the future power system. Such a high penetration of power electronics is changing power system operation landscapes and dynamic characteristics. Two major kinds of impact are reduced system mechanical inertia by inverter-based resources displacing conventional generation and active participation of many distributed energy resources through inverters. This has caused significant reliability challenges for power system operation. The mitigation approach so far has mostly focused on accommodating power electronics inverters as passive devices or creating synthetic inertias to make inverter-based generation behaving as conventional generators. However, the high-speed control capabilities of power electronics present new opportunities for achieving an optimal performance beyond conventional power systems. A lower-inertia system can be more responsive for improving reliability, and distributed small resources can be more adaptive and scalable for better flexibility and resilience. Power electronic inverters are capable of multiple fast control functions. To fully utilized the ubiquitous power electronics in power systems requires technology advancements in the following areas: data and communications to capture the new dynamic behaviors introduced by power electronics; modeling and simulation to understand the behaviors of power electronics and its interactions with other components in the context of power systems; control and optimization methods for fully utilizing the capabilities of power electronics for a new paradigm of performance beyond the traditional inertia-heavy system; and significant upgrades in power electronics hardware to cater to the new control capabilities. If properly controlled and optimized, power electronics can help transform the power system to be responsive, adaptive, and scalable.

Huang, Zhenyu↗

Review of the Recent Frequency Performance of the Eastern, Western and ERCOT Interconnections

The reliable operation of an electric power system depends on careful management of the balance between generation and load to ensure that system frequency is maintained within narrow bounds around a scheduled value. Yet, maintaining frequency at the scheduled value is challenging because the load served is continuously changing, and occasionally, events such as the sudden loss of a large generation plant or large amount of load, cause frequency to deviate abruptly. This report reviews the recent history of frequency performance for all three U.S. interconnections: Eastern, Western, and the Electric Reliability Council of Texas (ERCOT). The review is based on data collected by the North American Electric Reliability Corporation (NERC). The review focuses on frequency response, which measures the performance of the interconnections immediately following sudden, large imbalances between load and generation. Trends in frequency response are presented and preliminary efforts are made to relate frequency response to other aspects of frequency performance and to examine aspects of the methods used to calculate frequency response.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Hybrid Resources: Challenges, Implications, Opportunities, and Innovation

The electric power system has historically been designed to provide reliable energy to loads by using a relatively small number of well-understood generators. The distinction between load, generation, and transmission resources has been quite clear. Most of the responsibility for planning and operating a system - building a highly reliable network from less reliable parts - has been with the system manager, whether that be a utility, a regional market operator, or some similar entity. Given this historical context, many experts were initially perplexed by the rapidly growing popularity of hybrid resources, which combine multiple technologies into a single entity. Rather than depending on a system operator to provide instructions to individual technologies, hybrid resources intentionally take on more operational responsibility by optimizing and scheduling their combined functions. Interconnection queues in many regions reveal a large and growing interest in hybrids, suggesting that project developers and investors see them as providing advantages.

generators↗

Virtual Cable Impedance based Load Sharing in a Microgrid for Parallel Connected Grid Forming Converters

This paper presents a novel approach to power sharing between direct connected grid-forming converters, utilizing virtual cable impedance and droop-based outer loop control. To enhance stability, resistive droop is implemented, while virtual cable impedance with non-zero resistive and inductive components ensures improved power sharing. The inner loop controller employs a Lyapunov energy function to achieve superior dynamic performance. The proposed control architecture is validated through comprehensive modeling and real-time processor-in-the-loop simulations, demonstrating its robustness and efficiency under various operating conditions. The results highlight the potential of this control strategy to improve the reliability and efficiency of renewable energy systems. Additionally, a comparative analysis with traditional methods underscores the advantages of the proposed approach in terms of stability and performance. The proposed control architecture offers a scalable and flexible solution for grid-forming converters, enabling seamless integration of renewable energy sources. Its robustness and adaptability make it an attractive solution for real-world applications. Furthermore, the approach can be extended to other power electronic systems, enhancing overall system performance and efficiency. By providing a reliable and efficient control strategy, this paper contributes to the advancement of renewable energy systems and their adoption in the energy sector. The proposed control strategy has far-reaching implications for the widespread adoption of renewable energy sources, enabling a more sustainable and efficient energy future. The overall system is modeled in MATLAB/Simulink and PLECS software domain.

grid forming converters (GFM)↗

Hydrocarbon-free resonance transition 795-nm rubidium laser

An optical resonance transition rubidium laser (5{sup 2}P{sub 1/2} {yields} 5{sup 2}S{sub 1/2}) is demonstrated with a hydrocarbon-free buffer gas. Prior demonstrations of alkali resonance transition lasers have used ethane as either the buffer gas or a buffer gas component to promote rapid fine-structure mixing. However, our experience suggests that the alkali vapor reacts with the ethane producing carbon as one of the reaction products. This degrades long term laser reliability. Our recent experimental results with a 'clean' helium-only buffer gas system pumped by a Ti:sapphire laser demonstrate all the advantages of the original alkali laser system, but without the reliability issues associated with the use of ethane.

42 ENGINEERING↗

Modular Automated Processing System (MAPS) for analysis of biological samples.

We have developed a novel modular automated processing system (MAPS) that enables reliable, high-throughput analysis as well as sample-customized processing. This system is comprised of a set of independent modules that carry out individual sample processing functions: cell lysis, protein concentration (based on hydrophobic, ion-exchange and affinity interactions), interferent depletion, buffer exchange, and enzymatic digestion of proteins of interest. Taking advantage of its unique capacity for enclosed processing of intact bioparticulates (viruses, spores) and complex serum samples, we have used MAPS for analysis of BSL1 and BSL2 samples to identify specific protein markers through integration with the portable microChemLab{trademark} and MALDI.

59 BASIC BIOLOGICAL SCIENCES↗

Engineering Controls Database

Cyber-Informed Engineering (CIE) addresses the reality that cyber attacks on engineered systems can have consequences far beyond data loss or disruption of digital networks. When control systems are compromised, safety, reliability, and performance of the physical process itself may be threatened. This database is meant to establish clear examples and guidance for defining and applying engineered controls in CIE. It explains what engineered controls are, how they differ from information security measures, and how they are integrated into system design. The goal is to ensure that resilience is engineered into systems from the outset. Unlike cybersecurity protections that defend the digital layer, engineered controls act directly at the physical and algorithmic levels to guarantee that unacceptable consequences are prevented or limited. CIE keeps the consequences of a cyber attack from impacting the safety, reliability, and performance of engineered systems.

Source record↗

Cyber-Informed Engineering (CIE) – Engineered Controls Database and Use

Cyber-Informed Engineering (CIE) addresses the reality that cyber-attacks on engineered systems can have consequences far beyond data loss or disruption of digital networks. When control systems are compromised, safety, reliability, and performance of the physical process itself may be threatened. This database is meant to establish clear examples and guidance for defining and applying engineered controls in CIE. It explains what engineered controls are, how they differ from information security measures, and how they are integrated into system design. The goal is to ensure that resilience is engineered into systems from the outset. Unlike cybersecurity protections that defend the digital layer, engineered controls act directly at the physical and algorithmic levels to guarantee that unacceptable consequences are prevented or limited. CIE keeps the consequences of a cyber attack from impacting the safety, reliability, and performance of engineered systems.

42 - ENGINEERING↗

Electrical Energy Storage Data Submission Guidelines, Version 3

The knowledge of long-term health and reliability of energy storage systems is still unknown, yet these systems are proliferating and are expected increasingly to assist in the maintenance of grid reliability. Understanding long-term reliability and performance characteristics to the degree of knowledge similar to that of traditional utility assets requires operational data. This guideline is intended to inform numerous stakeholders on what data are needed for given functions, how to prescribe access to those data and the considerations impacting data architecture design, as well as provide these stakeholders insight into the data and data systems necessary to ensure storage can meet growing expectations in a safe and cost-efficient manner. Understanding data needs, the systems required, relevant standards, and user needs early in a project conception aids greatly in ensuring that a project ultimately performs to expectations.

25 ENERGY STORAGE↗

Digital Twin Based Condition Monitoring of LCC-LCC Inductive Power Transfer Systems

Inductive power transfer (IPT) systems provide a flexible, hands-free charging opportunity to electric vehicles (EV). The resonant network components and the transmitter and receiver coils are often subjected to high voltages or currents. Component aging in the compensation network and coils of resonant IPT systems is detrimental to the reliability and power transfer efficiency of the IPT system. Monitoring the component health of such multi-element complex systems requires robust optimization algorithms. This paper discusses condition monitoring of a resonant IPT system for an EV charger using a digital twin model. A hybrid estimation algorithm based on genetic algorithms and adaptive particle swarm optimization is developed to estimate the parameters of the digital twin model. Simulation results are used to verify the monitoring capabilities of the developed algorithm under various operating conditions of the IPT system.

Weldehawaryat, Lidya Mussie [graduate research ass↗