Search NASA⌕ Search

SEARCH · Search NASA

Results for “Testing metrics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

REAL TIME SYSTEM OPERATIONS 2006-2007

The Real Time System Operations (RTSO) 2006-2007 project focused on two parallel technical tasks: (1) Real-Time Applications of Phasors for Monitoring, Alarming and Control; and (2) Real-Time Voltage Security Assessment (RTVSA) Prototype Tool. The overall goal of the phasor applications project was to accelerate adoption and foster greater use of new, more accurate, time-synchronized phasor measurements by conducting research and prototyping applications on California ISO's phasor platform - Real-Time Dynamics Monitoring System (RTDMS) -- that provide previously unavailable information on the dynamic stability of the grid. Feasibility assessment studies were conducted on potential application of this technology for small-signal stability monitoring, validating/improving existing stability nomograms, conducting frequency response analysis, and obtaining real-time sensitivity information on key metrics to assess grid stress. Based on study findings, prototype applications for real-time visualization and alarming, small-signal stability monitoring, measurement based sensitivity analysis and frequency response assessment were developed, factory- and field-tested at the California ISO and at BPA. The goal of the RTVSA project was to provide California ISO with a prototype voltage security assessment tool that runs in real time within California ISO?s new reliability and congestion management system. CERTS conducted a technical assessment of appropriate algorithms, developed a prototype incorporating state-of-art algorithms (such as the continuation power flow, direct method, boundary orbiting method, and hyperplanes) into a framework most suitable for an operations environment. Based on study findings, a functional specification was prepared, which the California ISO has since used to procure a production-quality tool that is now a part of a suite of advanced computational tools that is used by California ISO for reliability and congestion management.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Space Launch System Accelerated Booster Development Cycle

With the retirement of the Space Shuttle, NASA is seeking to reinvigorate the national space program and recapture the public s interest in human space exploration by developing missions to the Moon, near-earth asteroids, Lagrange points, Mars, and beyond. The would-be successor to the Space Shuttle, NASA s Constellation Program, planned to take humans back to the Moon by 2020, but due to budgetary constraints was cancelled in 2010 in search of a more "affordable, sustainable, and realistic" concept2. Following a number of studies, the much anticipated Space Launch System (SLS) was unveiled in September of 2011. The SLS core architecture consists of a cryogenic first stage with five Space Shuttle Main Engines (SSMEs), and a cryogenic second stage using a new J-2X engine3. The baseline configuration employs two 5-segment solid rocket boosters to achieve a 70 metric ton payload capability, but a new, more capable booster system will be required to attain the goal of 130 metric tons to orbit. To this end, NASA s Marshall Space Flight Center recently released a NASA Research Announcement (NRA) entitled "Space Launch System (SLS) Advanced Booster Engineering Demonstration and/or Risk Reduction." The increased emphasis on affordability is evident in the language used in the NRA, which is focused on risk reduction "leading to an affordable Advanced Booster that meets the evolved capabilities of SLS" and "enabling competition" to "enhance SLS affordability. The purpose of the work presented in this paper is to perform an independent assessment of the elements that make up an affordable and realistic path forward for the SLS booster system, utilizing advanced design methods and technology evaluation techniques. The goal is to identify elements that will enable a more sustainable development program by exploring the trade space of heavy lift booster systems and focusing on affordability, operability, and reliability at the system and subsystem levels5. For this study, affordability is defined as lifecycle cost, which includes design, development, test, and engineering (DDT&E), production and operational costs (P&O). For this study, the system objectives include reducing DDT&E schedule by a factor of three, showing 99.9% reliability, flying up to four times per year, serving both crew and cargo missions, and evolving to a lift capability of 130 metric tons.3 After identifying gaps in the current system s capabilities, this study seeks to identify non-traditional and innovative technologies and processes that may improve performance in these areas and assess their impacts on booster system development. The DDT&E phase may be improved by incorporating incremental development testing and integrated demonstrations to mitigate risk. To further reduce DDT&E, this study will also consider how aspects of the booster system may have commonality with other users, such as the Department of Defense, commercial applications, or international partners; by sharing some of the risk and investment, the overall development cost may be reduced. Consideration is not limited to solid and liquid rocket boosters. A set of functional performance characteristics, such as engine thrust, specific impulse (Isp), mixture ratio, and throttle range are identified and their impacts on the system are evaluated. This study also identifies how such characteristics affect overall life cycle cost, including DDT&E and fixed and variable P&O.

Arockiam, Nicole↗

Extreme metrics from large ensembles: investigating the effects of ensemble size on their estimates

Abstract. We consider the problem of estimating the ensemble sizes required to characterize the forced component and the internal variability of a number of extreme metrics. While we exploit existing large ensembles, our perspective is that of a modeling center wanting to estimate a priori such sizes on the basis of an existing small ensemble (we assume the availability of only five members here). We therefore ask if such a small-size ensemble is sufficient to estimate accurately the population variance (i.e., the ensemble internal variability) and then apply a well-established formula that quantifies the expected error in the estimation of the population mean (i.e., the forced component) as a function of the sample size n, here taken to mean the ensemble size. We find that indeed we can anticipate errors in the estimation of the forced component for temperature and precipitation extremes as a function of n by plugging into the formula an estimate of the population variance derived on the basis of five members. For a range of spatial and temporal scales, forcing levels (we use simulations under Representative Concentration Pathway 8.5) and two models considered here as our proof of concept, it appears that an ensemble size of 20 or 25 members can provide estimates of the forced component for the extreme metrics considered that remain within small absolute and percentage errors. Additional members beyond 20 or 25 add only marginal precision to the estimate, and this remains true when statistical inference through extreme value analysis is used. We then ask about the ensemble size required to estimate the ensemble variance (a measure of internal variability) along the length of the simulation and – importantly – about the ensemble size required to detect significant changes in such variance along the simulation with increased external forcings. Using the F test, we find that estimates on the basis of only 5 or 10 ensemble members accurately represent the full ensemble variance even when the analysis is conducted at the grid-point scale. The detection of changes in the variance when comparing different times along the simulation, especially for the precipitation-based metrics, requires larger sizes but not larger than 15 or 20 members. While we recognize that there will always exist applications and metric definitions requiring larger statistical power and therefore ensemble sizes, our results suggest that for a wide range of analysis targets and scales an effective estimate of both forced component and internal variability can be achieved with sizes below 30 members. This invites consideration of the possibility of exploring additional sources of uncertainty, such as physics parameter settings, when designing ensemble simulations.

54 ENVIRONMENTAL SCIENCES↗

Trusted Communication: Utilizing Speech Communication to Enhance Human-Machine Teaming Success

An area of increasing interest for the next generation of aircraft is autonomy and the integration of increasingly autonomous systems into the national airspace. Such an integration requires humans to work closely with autonomous systems, forming teams. Our hypothesis is that a team composed of both humans and autonomous systems will operate better than either entity alone. We have existing procedures for certifying pilots to operate in the national airspace and are currently working on methods for validating the function of autonomous systems, however we have no method in place for assessing the interaction of these two disparate systems. Communication is one avenue. This paper will examine the use of language as a metric for ascertaining human-machine teaming effectiveness. A proof-of-concept of the application of two communication-based analysis techniques, Linguistic Inquiry and Word Count (LIWC) and Latent Semantic Analysis (LSA), for the prediction of success in human/chatbot teaming was conducted. By running these analyses over data from the 2014 and 2015 Loebner Prize competitions of human/chatbot teaming, numerical scores were obtained that can be associated with scores provided by human judges during the competition. Correlating their LIWC and LSA data with the scores provided by the judges, and using linear regression over this correlation, formulae were obtained that predict the score of human/chatbot interaction. These formulae were tested over the 2013 Loebner Prize transcripts, determining that, though there was strong correlation between predicted and actual scores, the predictive success of this method was not strong. However, with specialized topic spaces and lexica, as well as larger data sets, the predictive power of these metrics will improve. Given the importance of providing metrics for human-machine system team success and given the promise shown by the communication-basedLIWCand LSAmethods, continuing research in this area is necessary. After examining the potential for using communication and spoken language as a metric for the success of human/autonomous system teaming, this paper then examines aspects inherent to communication systems that may contribute to unreliability and reduced trust. Modern natural language processing tools rely on deep learning algorithms to create language rules that produce accurate results, but these rules are uninterpretable. The resulting blackbox system lacks transparency necessary for full validation and complete trust. Additionally, speech-based interfaces pose other difficulties to developing coordinated teamwork between humans and autonomous systems. Human communication is infrequently limited to speech only, instead usually relying on a combination of verbal, gestural, and general body language communication. Reducing an analysis of team effectiveness to a study of spoken language alone is problematic as it leaves these other equally important forms of communication out. This paper will examine these problems and the general deficiencies in speech-based metrics for human-machine teaming.

E L Meszaros↗

Using Demanded Power and RDE Aggressiveness Metrics to Analyze the Impact of CACC Aggressiveness on Heavy Duty Platooning Power Consumption

Presently, a main mobility sector objective is to reduce its impact on the global greenhouse gas emissions. While there are many techniques being explored, a promising approach to improve fuel economy is to reduce the required energy by using slipstream effects. This study analyzes the demanded engine power and mechanical energy used by heavy-duty trucks during platooning and non-platooning operation to determine the aerodynamic benefits of the slipstream. A series of platooning tests utilizing class 8 semi-trucks platooning via Cooperative Adaptive Cruise Control (CACC) are performed. Comparing the demanded engine power and mechanical energy used reveals the benefits of platooning on the aerodynamic drag while disregarding any potential negative side effects on the engine. However, energy savings were lower than expected in some cases. It was hypothesized that the CACC may have amplified transient platooning events relative to the individual truck baseline results, hampering the potential energy savings. Therefore, the impact of the controller on the observed driving style was analyzed in detail. In order to quantify the transient operational characteristics of the experimental trials, metrics from the European Real Driving Emissions (RDE) legislation were modified to serve as metrics of aggressiveness during platooning. The metrics (v · apos)95 and Relative Positive Acceleration (RPA) were calculated for platooning and non-platooning runs. These results indicate that the CACC induces small acceleration events during platooning to retain the commanded longitudinal separation between vehicles. These small acceleration events increase following vehicle aggressiveness during platooning and prevent the following vehicles from obtaining maximum energy savings. Moreover, a correlation between the RDE metric (v · apos)95 and energy savings is developed. Hence, this work establishes the ability of RDE metrics to assess CACC impacts on platoon energy savings.

European Real Driving Emissions, RDE, greenhouse g↗

Evaluating IMRT and VMAT dose accuracy: Practical examples of failure to detect systematic errors when applying a commonly used metric and action levels

Purpose: This study (1) examines a variety of real-world cases where systematic errors were not detected by widely accepted methods for IMRT/VMAT dosimetric accuracy evaluation, and (2) drills-down to identify failure modes and their corresponding means for detection, diagnosis, and mitigation. The primary goal of detailing these case studies is to explore different, more sensitive methods and metrics that could be used more effectively for evaluating accuracy of dose algorithms, delivery systems, and QA devices.Methods: The authors present seven real-world case studies representing a variety of combinations of the treatment planning system (TPS), linac, delivery modality, and systematic error type. These case studies are typical to what might be used as part of an IMRT or VMAT commissioning test suite, varying in complexity. Each case study is analyzed according to TG-119 instructions for gamma passing rates and action levels for per-beam and/or composite plan dosimetric QA. Then, each case study is analyzed in-depth with advanced diagnostic methods (dose profile examination, EPID-based measurements, dose difference pattern analysis, 3D measurement-guided dose reconstruction, and dose grid inspection) and more sensitive metrics (2% local normalization/2 mm DTA and estimated DVH comparisons).Results: For these case studies, the conventional 3%/3 mm gamma passing rates exceeded 99% for IMRT per-beam analyses and ranged from 93.9% to 100% for composite plan dose analysis, well above the TG-119 action levels of 90% and 88%, respectively. However, all cases had systematic errors that were detected only by using advanced diagnostic techniques and more sensitive metrics. The systematic errors caused variable but noteworthy impact, including estimated target dose coverage loss of up to 5.5% and local dose deviations up to 31.5%. Types of errors included TPS model settings, algorithm limitations, and modeling and alignment of QA phantoms in the TPS. Most of the errors were correctable after detection and diagnosis, and the uncorrectable errors provided useful information about system limitations, which is another key element of system commissioning.Conclusions: Many forms of relevant systematic errors can go undetected when the currently prevalent metrics for IMRT/VMAT commissioning are used. If alternative methods and metrics are used instead of (or in addition to) the conventional metrics, these errors are more likely to be detected, and only once they are detected can they be properly diagnosed and rooted out of the system. Removing systematic errors should be a goal not only of commissioning by the end users but also product validation by the manufacturers. For any systematic errors that cannot be removed, detecting and quantifying them is important as it will help the physicist understand the limits of the system and work with the manufacturer on improvements. In summary, IMRT and VMAT commissioning, along with product validation, would benefit from the retirement of the 3%/3 mm passing rates as a primary metric of performance, and the adoption instead of tighter tolerances, more diligent diagnostics, and more thorough analysis.

61 RADIATION PROTECTION AND DOSIMETRY↗

Relativistic radiation magnetohydrodynamics in dynamical spacetimes: Numerical methods and tests

Many systems of current interest in relativistic astrophysics require a knowledge of radiative transfer in a magnetized gas flowing in a strongly curved, dynamical spacetime. Such systems include coalescing compact binaries containing neutron stars or white dwarfs, disks around merging black holes, core-collapse supernovae, collapsars, and gamma-ray burst sources. To model these phenomena, all of which involve general relativity, radiation (photon and/or neutrino), and magnetohydrodynamics (MHD), we have developed a general relativistic code capable of evolving MHD fluids and radiation in dynamical spacetimes. Our code solves the coupled Einstein-Maxwell-MHD-radiation system of equations both in axisymmetry and in full 3+1 dimensions. We evolve the metric by integrating the BSSN (Baumgarte-Shapiro-Shibata-Nakamura) equations, and use a conservative, high-resolution shock-capturing scheme to evolve both the MHD and radiation moment equations. In this paper, we implement our scheme for optically thick gases and gray-body opacities. Our code gives accurate results in a suite of tests involving radiating shocks and nonlinear waves propagating in Minkowski spacetime. In addition, to test our code's ability to evolve the relativistic radiation-MHD equations in strong-field dynamical spacetimes, we study 'thermal Oppenheimer-Snyder collapse' to a black hole and find good agreement between analytic and numerical solutions.

79 ASTRONOMY AND ASTROPHYSICS↗

Recessional velocities and Hubble's law in Schwarzschild-de Sitter space

We consider a spacetime with empty Schwarzschild-de Sitter exterior and Schwarzschild-de Sitter interior metric for a spherical fluid with constant density. The fluid interior may be taken to represent a galaxy supercluster, for which the proper distance from the center of the supercluster to the cosmological horizon has the same order of magnitude as the Hubble radius derived from Friedmann-Robertson-Walker cosmologies. The fluid interior and surrounding vacuum may also be considered as a model of the Local Group of galaxies in the far future. Particle motion is subject both to the attractive gravity exerted by the fluid and the repelling cosmological constant. Using global Fermi coordinates for the central observer within the fluid, the Fermi velocity, the astrometric velocity, the kinematic velocity, and the spectroscopic velocity, relative to the central (Fermi) observer, of a radially receding test particle are calculated and compared. We find that the Fermi relative velocity can exceed the speed of light in this model, but the presence of a positive cosmological constant causes recessional speeds of distant high energy particles to decrease rather than increase. We derive a version of Hubble's law for this spacetime which might be applicable for the analysis of a receding mass within a great void adjacent to a supercluster, relatively isolated from gravitational sources other than the supercluster. We also compare some of our results to related behavior in Friedmann-Robertson-Walker cosmologies and consider implications to arguments regarding the expansion of space.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Using the Noether symmetry approach to probe the nature of dark energy

We propose to use a model-independent criterion based on first integrals of motion, due to Noether symmetries of the equations of motion, in order to classify the dark energy models in the context of scalar field (quintessence or phantom) Friedmann-Lemaitre-Robertson-Walker cosmologies. In general, the Noether symmetries play an important role in physics because they can be used to simplify a given system of differential equations as well as to determine the integrability of the system. The Noether symmetries are computed for nine distinct accelerating cosmological scenarios that contain a homogeneous scalar field associated with different types of potentials. We verify that all the scalar field potentials, presented here, admit the trivial first integral, namely, energy conservation, as they should. We also find that the exponential potential inspired from scalar field cosmology, as well as some types of hyperbolic potentials, include extra Noether symmetries. This feature suggests that these potentials should be preferred along the hierarchy of scalar field potentials. Finally, using the latter potentials, in the framework of either quintessence or phantom scalar field cosmologies that contain also a nonrelativistic matter (dark matter) component, we find that the main cosmological functions, such as the scale factor of the Universe, the scalar field, the Hubble expansion rate, and the metric of the Friedmann-Lemaitre-Robertson-Walker space-time, are computed analytically. Interestingly, under specific circumstances the predictions of the exponential and hyperbolic scalar field models are equivalent to those of the {Lambda}CDM model, as far as the global dynamics and the evolution of the scalar field are concerned. The present analysis suggests that our technique appears to be very competitive to other independent tests used to probe the functional form of a given potential and thus the associated nature of dark energy.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Cold Testing for Characterization of Oxide Feed Impurities in Support of the ARIES Program

The Advanced Recovery and Integrated Extraction System (ARIES) Program converts surplus plutonium metal components into an oxide powder form and packages the material for final disposition. In support of the ARIES program, over a metric ton (MT) of plutonium has been removed from surplus nuclear weapons since 1998 and packaged for long-term storage in 3013 cans. The oxide production rate is anticipated to increase substantially over the next decade in support of dilute and dispose goals. Analytical chemistry data from destructive analysis of the resulting 70+ blend lots to date has been reported for contaminants in the product oxide. Changes in the Pu product specification for Pu oxide product, induced by a different pit mix, the LANL swap program and processing Alternate (non-Pit Pu) Feed Stock (AFS) metals, will affect the level and the mix of these contaminants in the upcoming years. With these changes in feed material, it will be important to provide fast and efficient measurement of elemental impurities in the oxide to be certain that the process is under control and to monitor the anticipated changes from the historical blend lot data. Non-destructive methods need to be evaluated for the characterization of the plutonium oxide product and the quantification of the impurities at the current and anticipated levels. A feasibility study has begun to investigate the applicability of new spectroscopic methods for oxide impurity characterization. To this end, here we describe the preparation of surrogate materials to support these investigations, and the results of a feasibility study investigating the use of LIBS (Laser Induced Breakdown Spectroscopy) to characterize the surrogate materials as calibration standards.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Clinical Outcome Metrics for Optimization of Robust Training

Introduction: The emphasis of this research is on the Human Research Program (HRP) Exploration Medical Capability's (ExMC) "Risk of Unacceptable Health and Mission Outcomes Due to Limitations of In-Flight Medical Capabilities." Specifically, this project aims to contribute to the closure of gap ExMC 2.02: We do not know how the inclusion of a physician crew medical officer quantitatively impacts clinical outcomes during exploration missions. The experiments are specifically designed to address clinical outcome differences between physician and non-physician cohorts in both near-term and longer-term (mission impacting) outcomes. Methods: Medical simulations will systematically compare success of individual diagnostic and therapeutic procedure simulations performed by physician and non-physician crew medical officer (CMO) analogs using clearly defined short-term (individual procedure) outcome metrics. In the subsequent step of the project, the procedure simulation outcomes will be used as input to a modified version of the NASA Integrated Medical Model (IMM) to analyze the effect of the outcome (degree of success) of individual procedures (including successful, imperfectly performed, and failed procedures) on overall long-term clinical outcomes and the consequent mission impacts. The procedures to be simulated are endotracheal intubation, fundoscopic examination, kidney/urinary ultrasound, ultrasound-guided intravenous catheter insertion, and a differential diagnosis exercise. Multiple assessment techniques will be used, centered on medical procedure simulation studies occurring at 3, 6, and 12 months after initial training (as depicted in the following flow diagram of the experiment design). Discussion: Analysis of procedure outcomes in the physician and non-physician groups and their subsets (tested at different elapsed times post training) will allow the team to 1) define differences between physician and non-physician CMOs in terms of both procedure performance (pre-IMM analysis) and overall mitigation of the mission medical impact (IMM analysis); 2) refine the procedure outcome and clinical outcome metrics themselves; 3) refine or develop innovative medical training products and solutions to maximize CMO performance; and 4) validate the methods and products of this experiment for operational use in the planning, execution, and quality assurance of the CMO training process The team has finalized training protocols and developed a software training/testing tool in collaboration with Butler Graphics (Detroit, MI). In addition to the "hands on" medical procedure modules, the software includes a differential diagnosis exercise (limited clinical decision support tool) to evaluate the diagnostic skills of participants. Human subject testing will occur over the next year.

Ebert, D.↗

Proposing New RadLex Terms by Analyzing Free-Text Mammography Reports

After years of development, the RadLex terminology contains a large set of controlled terms for the radiology domain, but gaps still exist. We developed a data-driven approach to discover new terms for RadLex by mining a large corpus of radiology reports using natural language processing (NLP) methods. Our system, developed for mammography, discovers new candidate terms by analyzing noun phrases in free-text reports to extend the mammography part of RadLex. Our NLP system extracts noun phrases from free-text mammography reports and classifies these noun phrases as “Has Candidate RadLex Term” or “Does Not Have Candidate RadLex Term.” We tested the performance of our algorithm using 100 free-text mammography reports. An expert radiologist determined the true positive and true negative RadLex candidate terms. We calculated precision/positive predictive value and recall/sensitivity metrics to judge the system’s performance. Finally, to identify new candidate terms for enhancing RadLex, we applied our NLP method to 270,540 free-text mammography reports obtained from three academic institutions. Our method demonstrated precision/positive predictive value of 0.77 (159/206 terms) and a recall/sensitivity of 0.94 (159/170 terms). The overall accuracy of the system is 0.80 (235/293 terms). When we ran our system on the set of 270,540 reports, it found 31,800 unique noun phrases that are potential candidates for RadLex. Our data-driven approach to mining radiology reports can identify new candidate terms for expanding the breast imaging lexicon portion of RadLex and may be a useful approach for discovering new candidate terms from other radiology domains.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Explainable AI (XAI)-driven vibration sensing scheme for surface quality monitoring in a smart surface grinding process

Local Interpretable and Model-agnostic Explanation (LIME), an explainable artificial intelligence (XAI) approach is adapted to identify the globally important time-frequency bands for predicting average surface roughness (Ra) in a smart grinding process. The smart grinding setup consisted of a Supertech CNC precision surface grinding machine, instrumented with a Dytran piezoelectric accelerometer attached to the tailstock quill along the tangential direction (Y-axis). For every grinding pass, vibration signatures were captured, and the ground truth surface roughness values were recorded using a Mahr Marsurf M300C portable surface roughness profilometer. The roughness values ranged from 0.06 to 0.14 microns over the complete set of experiments. Time-frequency domain spectrogram frames were extracted for each of the vibration signals collected during the grinding process. Convolutional Neural Networks (CNNs) were modeled to predict the surface roughness based on these spectrogram frames and their image augmentations. The best CNN model was able to predict the roughness values with an overall R2-score of 0.95, training R2-score of 0.99, and testing R2-score of 0.81 with only 80 sets of vibration signals corresponding to 4 experiments with 20 trials each. Although the data size is not large enough to guarantee such performance metrics in real-world scenarios, one can extract statistically consistent explanations underlying the relationships these complex deep learning models capture. Further, the LIME methodology was implemented on the developed surface roughness CNN model to identify the important time-frequency bands (i.e., the superpixels of a spectrogram) influencing the predictions. Based on the identified important regions on the spectrogram frames, the corresponding frequency characteristics were determined that influence the surface roughness predictions. The important frequency range based on LIME results was approximately 11.7 to 19.1 kHz. The power of XAI was demonstrated by cutting down the sampling rate from 160 kHz to 30, 20, 10, and 5 kHz based on the important frequency range and considering Nyquist criteria. Separate CNN models were developed for these ranges by only extracting time-frequency contents below their corresponding Nyquist cut-offs. A proper data acquisition strategy is proposed by comparing the model performances to argue the selection of a sufficient sampling rate to capture the grinding process successfully and robustly.

42 ENGINEERING↗

Reprint of: Explainable AI (XAI)-driven vibration sensing scheme for surface quality monitoring in a smart surface grinding process

Local Interpretable and Model-agnostic Explanation (LIME), an explainable artificial intelligence (XAI) approach is adapted to identify the globally important time-frequency bands for predicting average surface roughness (Ra) in a smart grinding process. The smart grinding setup consisted of a Supertech CNC precision surface grinding machine, instrumented with a Dytran piezoelectric accelerometer attached to the tailstock quill along the tangential direction (Y-axis). For every grinding pass, vibration signatures were captured, and the ground truth surface roughness values were recorded using a Mahr Marsurf M300C portable surface roughness profilometer. The roughness values ranged from 0.06 to 0.14 microns over the complete set of experiments. Time-frequency domain spectrogram frames were extracted for each of the vibration signals collected during the grinding process. Convolutional Neural Networks (CNNs) were modeled to predict the surface roughness based on these spectrogram frames and their image augmentations. The best CNN model was able to predict the roughness values with an overall R2-score of 0.95, training R2-score of 0.99, and testing R2-score of 0.81 with only 80 sets of vibration signals corresponding to 4 experiments with 20 trials each. Although the data size is not large enough to guarantee such performance metrics in real-world scenarios, one can extract statistically consistent explanations underlying the relationships these complex deep learning models capture. Further, the LIME methodology was implemented on the developed surface roughness CNN model to identify the important time-frequency bands (i.e., the superpixels of a spectrogram) influencing the predictions. Based on the identified important regions on the spectrogram frames, the corresponding frequency characteristics were determined that influence the surface roughness predictions. The important frequency range based on LIME results was approximately 11.7 to 19.1 kHz. The power of XAI was demonstrated by cutting down the sampling rate from 160 kHz to 30, 20, 10, and 5 kHz based on the important frequency range and considering Nyquist criteria. Separate CNN models were developed for these ranges by only extracting time-frequency contents below their corresponding Nyquist cut-offs. A proper data acquisition strategy is proposed by comparing the model performances to argue the selection of a sufficient sampling rate to capture the grinding process successfully and robustly.

47 OTHER INSTRUMENTATION↗

On the validity of the Poisson assumption in sampling nanometer-sized aerosols

A Poisson process is traditionally believed to apply to the sampling of aerosols. For a constant aerosol concentration, it is assumed that a Poisson process describes the fluctuation in the measured concentration because aerosols are stochastically distributed in space. Recent studies, however, have shown that sampling of micrometer-sized aerosols has non-Poissonian behavior with positive correlations. The validity of the Poisson assumption for nanometer-sized aerosols has not been examined and thus was tested in this study. Its validity was tested for four particle sizes - 10 nm, 25 nm, 50 nm and 100 nm - by sampling from indoor air with a DMA- CPC setup to obtain a time series of particle counts. Five metrics were calculated from the data: pair-correlation function (PCF), time-averaged PCF, coefficient of variation, probability of measuring a concentration at least 25% greater than average, and posterior distributions from Bayesian inference. To identify departures from Poissonian behavior, these metrics were also calculated for 1,000 computer-generated Poisson time series with the same mean as the experimental data. For nearly all comparisons, the experimental data fell within the range of 80% of the Poisson-simulation values. Essentially, the metrics for the experimental data were indistinguishable from a simulated Poisson process. The greater influence of Brownian motion for nanometer-sized aerosols may explain the Poissonian behavior observed for smaller aerosols. Although the Poisson assumption was found to be valid in this study, it must be carefully applied as the results here do not definitively prove applicability in all sampling situations.

concentration measurement↗

Benchmarking noise extrapolation with the OpenPulse control framework

Distilling precise estimates from noisy intermediate scale quantum (NISQ) data has recently attracted considerable attention Kandala et al., Nature (London) 567, 491 (2019). In order to augment digital qubit metrics, such as gate fidelity, we discuss analog error mitigability, i.e., the ability to accurately distill precise observable estimates, as a hybrid quantum classical computing benchmarking task. Specifically, using Rabi oscillations as a test program, we characterize single qubit error rates on IBM's Poughkeepsie superconducting quantum hardware, incorporate control-mediated noise dependence into a generalized rescaling protocol, and analyze how noise characteristics influence Richardson extrapolation-based error mitigation. Finally, our results identify regions in the space of Hamiltonian control fields and circuit depth which are most amenable to reliable noise extrapolation, as well as shed light on how low-level hardware characterization can be used as a predictive tool for uncertainty quantification in error-mitigated NISQ computations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-E-T-379: Concave Approximations of Target Volume Dose Metrics for Intensity- Modulated Radiotherapy Treatment Planning

Purpose: The widely used treatment plan metric Dx (mimimum dose to the hottest x% by volume of the target volume) is simple to interpret and use, but is computationally poorly behaved (non-convex), this impedes its use in computationally efficient intensity-modulated radiotherapy (IMRT) treatment planning algorithms. We therefore searched for surrogate metrics that are concave, computationally efficient, and accurately correlated to Dx values in IMRT treatment plans. Methods: To find concave surrogates of D95—and more generally, Dx values with variable x values—we tested equations containing one or two generalized equivalent uniform dose (gEUD) functions. Fits were obtained by varying gEUD ‘a’ parameter values, as well as the linear equation coefficients. Fitting was performed using a dataset of dose-volume histograms from 498 de-identified head and neck IMRT treatment plans. Fit characteristics were tested using a crossvalidation process. Reported root-mean-square error values were averaged over the cross-validation shuffles. Results: As expected, the two-gEUD formula provided a superior fit, compared to the single-gEUD formula. The best approximation uses two gEUD terms: 16.25 x gEUD[a=0.45] – 15.30 x gEUD[a=1.75] – 0.69. The average root-mean-square error on repeated (70/30) cross validation was 0.94 Gy. In addition, a formula was found that reasonably approximates Dx for x between 80% and 96%. Conclusion: A simple concave function using two gEUD terms was found that correlates well with PTV D95s for these head and neck treatment plans. More generally, a formula was found that represents well the Dx for x values from 80% to 96%, thus providing a computationally efficient formula for use in treatment planning optimization. The formula may need to be adjusted for other institutions with different treatment planning protocols. We conclude that the strategy of replacing Dx values with gEUD-based formulas is promising.

60 APPLIED LIFE SCIENCES↗

WE-AB-207A-01: BEST IN PHYSICS (IMAGING): High-Resolution Cone-Beam CT of the Extremities and Cancellous Bone Architecture with a CMOS Detector

Purpose: Extremity cone-beam CT (CBCT) with an amorphous silicon (aSi) flat-panel detector (FPD) provides low-dose volumetric imaging with high spatial resolution. We investigate the performance of the newer complementary metal-oxide semiconductor (CMOS) detectors to enhance resolution of extremities CBCT to ∼0.1 mm, enabling morphological analysis of trabecular bone. Quantitative in-vivo imaging of bone microarchitecture could present an important advance for osteoporosis and osteoarthritis diagnosis and therapy assessment. Methods: Cascaded systems models of CMOS- and FPD-based extremities CBCT were implemented. Performance was compared for a range of pixel sizes (0.05–0.4 mm), focal spot sizes (0.3–0.6 FS), and x-ray techniques (0.05–0.8 mAs/projection) using detectability of high-, low-, and all-frequency tasks for a nonprewhitening observer. Test-bench implementation of CMOS-based extremity CBCT involved a Teledyne DALSA Xineos3030HR detector with 0.099 mm pixels and a compact rotating anode x-ray source with 0.3 FS (IMD RTM37). Metrics of bone morphology obtained using CMOS-based CBCT were compared in cadaveric specimens to FPD-based system using a Varian PaxScan4030 (0.194 mm pixels). Results: Finer pixel size and reduced electronic noise for CMOS (136 e compared to 2000 e for FPD) resulted in ∼1.9× increase in detectability for high-frequency tasks and ∼1.1× increase for all-frequency tasks. Incorporation of the new x-ray source with reduced focal spot size (0.3 FS vs. 0.5 FS used on current extremities CBCT) improved detectability for CMOS-based CBCT by ∼1.7× for high-frequency tasks. Compared to FPD CBCT, the CMOS detector yielded improved agreement with micro-CT in measurements of trabecular thickness (∼1.7× reduction in relative error), bone volume (∼1.5× reduction), and trabecular spacing (∼3.5× reduction). Conclusion: Imaging performance modelling and experimentation indicate substantial improvements for high-frequency imaging tasks through adoption of the CMOS detector and small FS x-ray source, motivating the use of these components in a new system for quantitative in-vivo imaging of trabecular bone. Financial Support: US NIH grant R01EB018896. Qian Cao is a Howard Hughes Medical Institute International Student Research Fellow. Disclosures: W Zbijewski, J Siewerdsen and A Sisniega receive research funding from Carestream Health.

60 APPLIED LIFE SCIENCES↗