Search NASA⌕ Search

SEARCH · Search NASA

Results for “Thick Target”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

SU-E-J-64: Feasibility Study of Surgical Clips for Fiducial Tracking in CyberKnife System

Purpose: To investigate the ability of CyberKnife to track surgical clips used as fiducial markers. Methods: The Octavius 1000SRS detector and solid water (RW3) slab phantom were used with motion platform to evaluate the study. The RW3 slab phantom was set up to measure the dose distribution from coronal plane. It consists of 9 plates and the thickness of each plate is 10mm. Among them, one plate was attached with 3 surgical clips, which are orthogonally positioned on outer region of array. The length of attached clip was represented as 1cm on planning CT. The clip plate was placed on the 1000SRS detector and 3 slabs were stacked up on the plate to build the measuring depth. Below the detector, 5 slabs were set. The two-axis motion platform was programmed with 1D sinusoidal movement (20mm peak-to-peak, 3s period) toward superior/inferior and left/right directions to simulate target motion. During delivery, two clips were extracted by two X-ray imagers, which led to translational error correction only. Synchrony was also used for dynamic tracking. After the irradiation, the measured dose distribution of coronal plane was compared with the planar dose distribution calculated by the CyberKnife treatment planning system (Multiplan) for cross verification. The results were assessed by comparing the absolute Gamma (γ) index. Results: The dose distributions measured by the 1000SRS detector were in good agreements with those calculated by Multiplan. In the dosimetric comparison using γ-function criteria based on the distance-to-agreement of 3mm and the local dose difference of 3%, the passing rate with γ- parameter ≤1 was 91% in coronal plane. Conclusion: The surgical clips can be considered as new fiducials for robotic radiosurgery delivery by considering the target margin with less than 5mm.

60 APPLIED LIFE SCIENCES↗

Multifunctional Polar 2D Lead Iodide Perovskites Exhibiting Persistent Spin Texture

Ferroelectric Rashba semiconductors are a rare class of multifunctional materials promising for spin–orbitronics due to the possibility of electrically switchable spin textures. Hybrid organic–inorganic metal halide perovskites offer exceptional tunability that can be harnessed to target noncentrosymmetry; however, the complex interactions between organic and inorganic components are not rationally understood. Here, we use an asymmetric spacer cation with a strong molecular dipole moment (2-fluorobenzylammonium, 2FBZ) and increase the intrinsic quantum well thickness to n > 1 to synthesize three new polar 2D lead iodide perovskites (2FBZ) 2 (A) n-1 Pb n I 3n+1 with A = methylammonium (MA) or formamidinium (FA) and n = 2, 3. Single-crystal structure analysis reveals the C 2v symmetry of these crystal structures and substantial structural distortions, which enable Rashba and Dresselhaus band splitting and persistent spin texture, confirmed by DFT calculations. Measurements of the resulting symmetry-dependent properties, such as second harmonic generation, switchable photovoltaic effect, ferroelectric polarization, and low temperature photoluminescence show switchable ferroelectric semiconducting properties. Furthermore, these results introduce a general chemical design strategy toward polar symmetry by exploiting the complex interplay between asymmetric spacer cations and A-site cations in quasi-2D (n > 1) halide perovskites to realize new classes of multifunctional materials for future spin–orbitronic applications.

Cations↗

Angle-dependent modulated spectral peaks of proton beams generated in ultrashort intense laser-solid interactions

Proton acceleration from 4 μm thick aluminum foils irradiated by 30-TW Ti:sapphire laser pulses is investigated using an angle-resolved proton energy spectrometer. We find that a modulated spectral peak at ∼0.82 MeV is presented at 2.5° off the target normal direction. The divergence angle of the modulated zone is 3.8°. Two-dimensional particle-in-cell simulations reveal that self-generated toroidal magnetic field at the rear surface of the target foil is responsible for the modulated spectral feature. The field deflects the low energy protons, resulting in the modulated energy spectrum with certain peaks.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Plasma Jet Driven Magneto-Inertial Fusion (PJMIF)

We report that PJMIF is the only embodiment of magneto-inertial fusion that has the unique combination of standoff implosion and high implosion velocity (50 km/s - 150 km/s). It uses inexpensive plasma guns for all plasma formation and implosion. It has potential for relatively high repetition rate from 1 to 2 Hz. Its configuration is compatible with the use of a thick liquid wall that doubles as a tritium breeding blanket as well as a coolant for extracting the heat out of the fusion reactor. Its operational parameter space allows for the possibility of using a suffciently dense target plasma for the target plasma to have a high beta. If such a high beta plasma could be realized, it would help to suppress micro and MHD instabilities, giving its target plasma classical transport and energy confinement characteristics. Its open geometry and moderate time and spatial scales provide convenient diagnostics access. Diagnostics accessibility, high shot rate and low cost per shot should enable quick resolution of technical issues during development, thus the potential for enabling rapid R&D of PJMIF. There are a number of challenges, however, for PJMIF including being at a very early stage of development, developing the required plasma guns, dealing with potential liner non-uniformities, clearing the chamber of residual high-Z gas between shots, and developing the repetitive pulsed power component technologies. Over the last three years, the development of the Plasma Liner Formation Experiment (PLX-alpha) have been undertaken to explore the physics and demonstrate the formation of a spherical liner by the merging of a spherical array of plasma jets. Two- and three- jet merging experiments have been conducted to study the interactions of the jets. Lastly, six- and seven-jet experiments have been performed to form a piece of the plasma liner. A brief status report on this development is provided in this paper.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The vertical metallicity gradient of the Milky Way disk: transitions in [α/Fe] populations

Using G dwarfs from the Sloan Extension for Galactic Understanding and Exploration (SEGUE) survey, we have determined the vertical metallicity gradient in the Milky Way's disk and examined how this gradient varies for different [α/Fe] subsamples. Our sample contains over 40,000 stars with low-resolution spectroscopy over 144 lines of sight. It also covers a significant disk volume, between ∼0.3 and 1.6 kpc from the Galactic plane, and allows us to examine the disk in situ, whereas previous analyses were more limited in scope. Furthermore, this work does not presuppose a disk structure, whether composed of a single complex population or distinct thin and thick disk components. We employ the SEGUE Stellar Parameter Pipeline to obtain estimates of stellar parameters, [Fe/H], and [α/Fe] and extract multiple volume-complete subsamples of approximately 1000 stars each. Based on SEGUE's target-selection algorithm, we adjust each subsample to determine an unbiased picture of disk chemistry; consequently, each individual star represents the properties of many. The metallicity gradient is –0.243{sub −0.053}{sup +0.039} dex kpc{sup –1} for the entire sample, which we compare to various literature results. This gradient stems from the different [α/Fe] populations inhabiting different ranges of height above the Galactic plane. Each [α/Fe] subsample shows little change in median [Fe/H] with height. If we associate [α/Fe] with age, the negligible gradients of our [α/Fe] subsamples suggest that stars formed in different epochs exhibit comparable vertical structure, implying similar star formation processes and evolution.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-F-BRA-04: Prostate HDR Brachytherapy with Multichannel Robotic System

Purpose: High-dose-rate (HDR) brachytherapy is gradually becoming popular in treating patients with prostate cancers. However, placement of the HDR needles at desired locations into the patient is challenging. Application of robotic system may improve the accuracy of the clinical procedure. This experimental study is to evaluate the feasibility of using a multichannel robotic system for prostate HDR brachytherapy. Methods: In this experimental study, the robotic system employed was a 6-DOF Multichannel Image-guided Robotic Assistant for Brachytherapy (MIRAB), which was designed and fabricated for prostate seed implantation. The MIRAB has the provision of rotating 16 needles while inserting them. Ten prostate HDR brachytherapy needles were simultaneously inserted using MIRAB into a commercially available prostate phantom. After inserting the needles into the prostate phantom at desired locations, 2mm thick CT slices were obtained for dosimetric planning. HDR plan was generated using Oncetra planning system with a total prescription dose of 34Gy in 4 fractions. Plan quality was evaluated considering dose coverage to prostate and planning target volume (PTV), with 3mm margin around prostate, as well as the dose limit to the organs at risk (OARs) following the American Brachytherapy Society (ABS) guidelines. Results: From the CT scan, it is observed that the needles were inserted straight into the desired locations and they were adequately spaced and distributed for a clinically acceptable HDR plan. Coverage to PTV and prostate were about 91% (V100= 91%) and 96% (V100=96%), respectively. Dose to 1cc of urethra, rectum, and bladder were within the ABS specified limits. Conclusion: The MIRAB was able to insert multiple needles simultaneously into the prostate precisely. By controlling the MIRAB to insert all the ten utilized needles into the prostate phantom, we could achieve the robotic HDR brachytherapy successfully. Further study for assessing the system’s performance and reliability is in progress.

60 APPLIED LIFE SCIENCES↗

Overview of the Geoanalytical Economic Evaluation of Saline Storage (GEESS) System

This report provides an overview on the Geoanalytical Economic Evaluation of Saline Storage (GEESS) system which characterized 57 geologic saline formations targeted for geologic carbon storage across the lower-48 U.S. states using publicly available resources. The GEESS system consists of high spatial resolution datasets (up to 5 km grid spacing) that provide key geologic parameters (e.g., depth, thickness, permeability), and estimates of CO 2 plume size and CO 2 first-year break-even price that were determined by exercising GEESS data through the FECM/NETL CO 2 Saline Storage Cost Model (CO2_S_COM). The GEESS geodatabase is available on NETL’s EDX at GEESS Geodatabase.

54 ENVIRONMENTAL SCIENCES↗

Measuring coal deposits by radar

Front-surface, local-oscillator radar directly compares frequency of signals reflected from front and back surfaces of coal deposits. Thickness is measured directly as frequency difference. Transmitter is frequency modulated, so thickness is computed directly from frequency difference. Because front and back reflections are detected in combination rather than separately, masking of comparatively weak back signal is less problem. Also system is not sensitive to extraneous reflections from targets between transmitting antenna and coal surface.

Barr, T. A.↗

The high energy transmission grating spectrometer for AXAF

Attention is given to a high energy transmission grating spectrometer that operates over the range 0.4-8 keV, giving resolving powers of 100-1000 and effective areas of 10-200 sq cm. The instrument, which is part of the MIT high resolution X-ray spectroscopy investigation, consists of a single array of grating facets of two types: medium energy gratings of 0.6-micron period, 0.5-micron thick silver mounted behind the outer three AXAF mirrors, and high energy gratings of 0.2-micron period, 1.0-micron thick gold mounted behind the inner three mirrors. The gratings are oriented so as to correct for coma and so that the medium and high energy spectra form a shallow 'X' at the AXAF focal plane. Likely targets include normal stars, binary X-ray sources, active galactic nuclei and quasars. The HETGS can also be used to give moderate resolution spectra of slightly extended sources and monochromatic images of sources with strong lines, such as supernova remnants in nearby galaxies.

Canizares, C. R.↗

Tailoring the Stiffness of Large Mirrors to Reduce Specific Optical Aberrations

Presented is a method that tailors the geometry of a mirror’s core structure as well as the mounting interface such that a desired set of aberrations is reduced. It will be shown that targeting specific aberrations as opposed to reducing overall surface figure error (SFE) is a valid method to reduce weight or improve performance. Analyzed first is the self-weight deflection of a thin circular plate of uniform thickness continuously supported along its outer edge. The Kirchhoff-Love plate bending equations are related to the radially symmetric Zernike polynomials of piston, defocus, and primary spherical aberration. Next, the mirror’s radial thickness is optimized to eliminate primary and secondary spherical aberrations when the outer edge is simply supported. As an example, the method is demonstrated using a 2-meter diameter aluminum mirror where surface deflections can have an appreciable effect at mid-to-near infrared wavelengths

mirror stiffness optimization↗

Performance of Polymer Electrolyte Fuel Cell Electrodes with Atomically Dispersed (AD) Fe-C-N ORR Catalyst

Activity of (AD)Fe-N-C catalyst with low Fe content is investigated in differential cells prepared by hot pressing anode gas diffusion electrodes (0.2 mgPt/cm2) to N211 membrane and brush painting the cathode catalyst ink. Polarization curves obtained in H2/O2 show double Tafel slopes which, in conjunction with the redox potential observed in cyclic voltammetry traces, forms the basis for a distributed ORR (oxygen reduction reaction) kinetic model with potential-dependent available sites. Application of this model to polarization data in H2/air provides the basis for formulating an oxygen transport model and leads to 7.7 ± 0.6 mA/cm2 catalyst activity at 0.9 V, 31.5-34.3 mA/cm2 cell performance at 0.8 V, and 0.8-2 s/cm O2 transport resistance. A coupled kinetic, O2 transport and proton transport illustrates the projected improvements needed in catalyst activity and electrode structure to approach the automotive target of 1000 mW/cm2 stack power density while meeting the 1.45 kW/oC heat rejection constraint at 1.5 cathode stoichiometry. The model indicates that we need twelve-fold higher mass activity for reducing the kinetic losses, doubling of active site density and an engineered electrode structure for 50% lower proton transport resistance, as well as a 50% reduction in electrode thickness to limit the O2 transport losses

ACTIVE-SITES↗

Mass-ablation-rate measurements in direct-drive cryogenic implosions using x-ray self-emission images

A technique to measure the mass ablation rate in direct-drive inertial confinement fusion implosions using a pinhole x-ray framing camera is presented. In target designs consisting of two layers of different materials, two x-ray self-emission peaks from the coronal plasma were measured once the laser burned through the higher-Z outer layer. The location of the inner peak is related to the position of the ablation front and the location of the outer peak corresponds to the position of the interface of the two layers in the plasma. The emergence of the second peak was used to measure the burnthrough time of the outer layer, giving the average mass ablation rate of the material and instantaneous mass remaining. By varying the thickness of the outer layer, the mass ablation rate can be obtained as a function of time. Simulations were used to validate the methods and verify that the measurement techniques are not sensitive to perturbation growth at the ablation surface.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Novel Capsule Fill Tube Assemblies for the Hydrodynamic Growth Radiography Targets

Capsule Fill Tube Assemblies (CFTAs) consist of an ablator capsule and fill tube via a laser drilled funnel hole. This hole then tapers from 17 μm diameter at the outer surface of the ablator capsule to less than 5 μm diameter on the inside of the capsule over approximately 200 μm of wall thickness. Demand for better understanding of the fill tube perturbation during the capsule implosion has driven advancements in the fill tube design. Engineering efforts have been made on Hydrodynamic Growth Radiography Assemblies (HGRs) using multiple tube design variations, including alternative angles, depths, sizes, and location with engineered defects to showcase fill tube effects during an implosion. Furthermore, testing has shown that these CFTAs and HGRs have survived all fabrication and transport to from General Atomics to Lawrence Livermore National Laboratory. These assemblies have also passed cryogenic testing at General Atomics. An overview of alternative CFTA designs, fabrication methods and developments will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-precision Stellar Limb-darkening in Exoplanetary Transits

Characterization of the atmospheres of transiting exoplanets relies on accurate measurements of the extent of the optically thick area of the planet at multiple wavelengths with a precision ≲100 parts per million (ppm). Next-generation instruments onboard the James Webb Space Telescope (JWST) are expected to achieve ∼10 ppm precision for several tens of targets. A similar precision can be obtained in modeling only if other astrophysical effects, including the stellar limb-darkening, are properly accounted for. In this paper, we explore the limits on precision due to the mathematical formulas currently adopted to approximate the stellar limb-darkening, and due to the use of limb-darkening coefficients obtained either from stellar-atmosphere models or empirically. We recommend the use of a two-coefficient limb-darkening law, named “power-2,” which outperforms other two-coefficient laws adopted in the exoplanet literature in most cases, and particularly for cool stars. Empirical limb-darkening based on two-coefficient formulas can be significantly biased, even if the light-curve residuals are nearly photon-noise limited. We demonstrate an optimal strategy to fitting for the four-coefficient limb-darkening in the visible, using prior information on the exoplanet orbital parameters to break some of the degeneracies that otherwise would prevent the convergence of the fit. Infrared observations taken with the JWST will provide accurate measurements of the exoplanet orbital parameters with unprecedented precision, which can be used as priors to improve the stellar limb-darkening characterization, and therefore the inferred exoplanet parameters, from observations in the visible, such as those taken with Kepler/K2, the JWST, and other past and future instruments.

79 ASTRONOMY AND ASTROPHYSICS↗

A Search for Signs of Life and Habitability on Europa

Europa is a key target in the search for life beyond the Earth because of consistent evidence that below the icy surface there is liquid water. Future missions to Europa could confirm the presence and nature of the ocean and determine the thickness of the ice layer. Confirming the presence of an ocean and determining the habitability of Europa are key astrobiology science objectives. Nevertheless, the highest priority objective for astrobiology will be a search for life. How could a search for life be accomplished on a near-term mission given the thick ice cover? One answer may lie in the surface materials. If Europa has an ocean, and if that ocean contains life, and if water from the ocean is carried up to the surface, then signs of life may be contained in organic material on the surface. Organics that derive from biological processes (dead organisms) are distinct from organics derived from non-biological processes in several aspects. First, biology is selective and specific in its use of molecules. For example, Earth life uses 20 left-handed amino acids. Second, biology can leave characteristic isotopic patterns. Third, biology often produces large complex molecules in high concentrations, for example lipids. Organic material that has been on the surface of Europa for long periods of time would be reprocessed by the strong radiation field probably erasing any signature of biological origin. Evidence of life in the ocean may be found on the surface of Europa if regions of the surface contained relatively recent material carried up from the ocean through cracks in the icy lithosphere. But organic material that has been on the surface of Europa for long periods of time would be reprocessed by the strong radiation field probably erasing any signature of biological origin. Thus, the detailed analysis required may not be possible via remote sensing but direct sampling of the material below the radiation processed upper meter is probably required.

Fonda, Mark↗

Avoidance of Tearing Mode Locking and Disruption with Electro-Magnetic Torque Introduced by Feedback-based Mode Rotation Control in DIII-D and RFX-mod

Disruptions caused by tearing modes (TMs) are considered to be one of the most critical roadblocks to achieving reliable, steady-state operation of tokamak fusion reactors. Here we have demonstrated a very promising scheme to avoid such disruptions by utilizing the electro-magnetic (EM) torque produced with 3D coils that are available in many tokamaks. In this scheme, the EM torque to the modes is created by a toroidal phase shift between the externally-applied field and the excited TM fields, compensating for the mode momentum loss due to the interaction with the resistive wall and uncorrected error fields. Fine control of torque balance is provided by a feedback scheme. We have explored this approach in two vastly different devices and plasma conditions: DIII-D and RFX-mod operated in tokamak mode. In DIII-D, the plasma target was high βN plasmas in a non-circular divertor tokamak. In RFX-mod, the plasma was ohmically-heated plasma with ultralow safety factor in a circular limiter discharge of active feedback coils outside the thick resistive shell. The DIII-D and RFX-mod experiments showed remarkable consistency with theoretical predictions of torque balance. The application to ignition-oriented devices such as International Thermonuclear Experimental Reactor (ITER) would expand the horizon of its operational regime. The internal 3D coil set currently under consideration for edge localized mode suppression in ITER would be well suited to this purpose.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-F-T-27: A Comparative Case Study Among Four Modalities for the Superficial Treatment of Squamous Cell Carcinoma

Purpose: We performed a comparative planning study among High Dose Rate (HDR) brachytherapy, superficial electrons, Volume Modulated Arc Therapy (VMAT), and Helical IMRT (Tomotherapy) for squamous cell carcinoma of the abdominal wall with consideration for the underlining bowel. Methods: A 69-year old female presented with squamous cell carcinoma protruding 8mm beyond the anterior skin surface of the midabdomen was considered for treatment. The patient had a ventral hernia which resulted in the reduction of the abdominal wall thickness and the adjacent small bowel being the dose limiting structure. Four plans were generated using different treatment modalities: a) an enface electron field (eMC, Eclipse v. 11), b) Tomotherapy (HI-Art II v.5.0.5), c) VMAT (Acuros, Eclipse v. 11), and d) HDR using a Freiburg applicator (Oncentra v. 4.3). The following plan objectives were used for all four plans: for the CTV target, V90% ≥90% (61.8Gy2/2).For the small bowel, D0.1cc < 56.2 Gy2/2 was a hard constraint and expressed as a percentage of the prescription for comparison to demonstrate the dose fall-off achieved among the modalities.For HDR, V200% <0.1cc was an additional constraint. Multiple dosimetric parameters, including those listed above, were compared among the four modalities. Results: The HDR plan showed comparable target coverage compared to the Tomotherapy plan and better coverage compared to the electron plan. Small bowel doses (D0.1cc) were lower in HDR plan compared to Tomotherapy, electron, & VMAT plans (88.8%, 89.6%, 90.9%, & 96.6%). Integral dose to the whole body (V5%) was much higher for HDR, VMAT, and Tomotherapy when compared to electron plan by factors of seven, eight, and ten, respectively. After reviewing all treatment modalities, the physician selected HDR owing to better control of the small bowel dose while maintaining adequate target coverage. Conclusion: This case study demonstrated HDR can successfully treat superficial lesions with superior sparing of underlying structures.

60 APPLIED LIFE SCIENCES↗