Search NASA⌕ Search

SEARCH · Search NASA

Results for “VAPORIZATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

Collapse of large vapor bubbles

The refilling of propellant tanks while in a low-gravity environment requires that entrapped vapor bubbles be collapsed by increasing the system pressure. Tests were performed to verify the mechanism of collapse for these large vapor bubbles with the thermodynamic conditions, geometry, and boundary conditions being those applicable to propellant storage systems. For these conditions it was found that conduction heat transfer determined the collapse rate, with the specific bubble geometry having a significant influence.

Tegart, J.↗

Convective and morphological instability in vapor crystal growth

Theoretical and experimental work on the fluid dynamics of physical vapor transport is reported. It is shown that diffusion in viscous interaction with container walls leads to concentration gradients normal to the main transport direction. Consequently any convection threshold is removed. This coupling with convective instabilities makes the theoretical interpretation of earthbound (anisotropic) morphological stability studies on vapor-solid interfaces intractable. Hence low-gravity experiments are suggested that will allow for the establishment of morphological stability criteria under diffusion controlled conditions.

Rosenberger, F.↗

Preprototype Vapor Compression Distillation Subsystem development

Vapor Compression Distillation (VCD) has evolved as the most promising approach to reclaim potable water from wastewater for future long-term manned space missions. Life Systems, Inc. (LSI), working with NASA, has developed a preprototype Vapor Compression Distillation Subsystem (VCDS) which processes wastewater at 1.4 kg/h. The preprototype unit weighs 143 kg, occupies a volume of 0.47 cu m, and will reclaim 96 percent of the available wastewater. This unit has been tested by LSI and is scheduled for further testing at NASA-JSC. This paper presents the preprototype VCDS design, configuration, performance data, test results and flight system projections.

Thompson, C. D.↗

Dispersion of flammable vapor clouds resulting from large spills of liquid hydrogen

The purpose of this paper is to report the preliminary findings of hydrogen vapor cloud dispersion experiments conducted by NASA. The experiments were performed to obtain basic information regarding the physical phenomena governing the dispersion of flammable clouds formed as the result of spills of large quantities of liquid hydrogen. The experiments consisted of ground spills of up to 5.7 cubic meters (1500 gal) of liquid hydrogen, with spill durations of approximately 35 seconds. Instrumented towers, located downwind of the spill site, gather data on the temperature, hydrogen concentration, and turbulence levels as the hydrogen vapor cloud drifted downwind. Visual phenomena were recorded by motion picture and still cameras. Preliminary results of the experiments indicate that, for rapid spills, thermal and momentum induced turbulences cause the cloud to disperse to safe concentration levels and become positively buoyant long before mixing due to normal atmospheric turbulence becomes a major factor.

Witcofski, R. D.↗

Absorptivity of water vapor for 10.6 micron radiation

Attention is called to recent measurements of the absorptivity of water vapor to 10.6-micron laser radiation made using shock-heated H2O/H2 and H2O/Ar mixtures and a probe CO2 laser. It is noted that these measurements give values about a factor of 2 lower than Ludwig's (1971) low resolution values. It is also argued that Fowler's (1981) high values are not likely to be caused by excited water molecules. It is shown that very intense laser radiation would be required to obtain any appreciable vibrational nonequilibrium. Within the narrow spectral range of 944-948/cm, no significant variation in absorption coefficient (suitably normalized) is observed as a function of laser line, water vapor concentration, total pressure, or diluent gas.

Pugh, E. R.↗

Experimental study of external fuel vaporization

The fuel properties used in the design of a flash vaporization system for aircraft gas turbine engines were evaluated in experiments using a flowing system to determine critical temperature and pressure, boiling points, dew points, heat transfer coefficients, deposit formation rates, and deposit removal. Three fuels were included in the experiments: Jet-A, an experimental referree broad specification fuel, and a premium No. 2 diesel fuel. Engine conditions representing a NASA Energy Efficient Engine at sea-level take-off, cruise, and idle were simulated in the vaporization system and it was found that single phase flow was maintained in the heat exchanger and downstream of the throttle. Deposits encountered in the heat exchanger represented a thermal resistance as high as 1300 sq M K/watt and a deposit formation rate over 1000 gC/sq cm hr.

Szetela, E. J.↗

Packed Alumina Absorbs Hypergolic Vapors

Beds of activated alumina effective as filters to remove hypergolic vapors from gas streams. Beds absorb such substances as nitrogen oxides and hydrazines and may also absorb acetylene, ethylene, hydrogen sulfide, benzene, butadiene, butene, styrene, toluene, and xoylene. Bed has no moving parts such as pumps, blowers and mixers. Reliable and energy-conservative. Bed readily adapted to any size from small portable units for use where little vapor release is expected to large stationary units for extensive transfer operations.

Thomas, J. J.↗

Description and overview of an instrument designed to measure line-of-sight delay due to water vapor

Eight dual channel microwave radiometers were constructed as a research and development effort for the Crustal Dynamics Project and the Deep Space Network. These instruments, known as water vapor radiometers, are primarily intended to demonstrate that the variable path delay imposed by atmospheric water vapor can be calibrated in microwave tracking and distance measuring systems but could also be used in other applications involving moist air meteorology and propagation studies. They are being deployed to various stations and observatories that participate in Very Long Baseline Interferometry experiments. The development history of these instruments are reviewed, the theory of operation and overall design considerations are outlined, and the instrumental parameters and performance characteristics are described.

Resch, G. M.↗

Low-level water vapor fields from the VAS split-window channels at 11 and 12 microns

Originally, the VAS split window channels were designed to use the differential water vapor absorption between 11 and 12 microns to estimate sea surface temperature by correcting for the radiometric losses caused by atmospheric moisture. It is shown that it is possible to reverse the procedure in order to estimate the vertically integrated low level moisture content with the background surface (skin) temperature removed, even over the bright, complex background of the land. Because the lower troposphere's water vapor content is an important factor in convective instability, the derived fields are of considerable value to mesoscale meteorology. Moisture patterns are available as quantitative fields (centimeters of precipitable water) at full VAS resolution (as fine as 7 kilometers horizontal resolution every 15 minutes), and are readily converted to image format for false color movies. The technique, demonstrated with GOES-5, uses a sequence of split window radiances taken once every 3 hours from dawn to dusk over the Eastern and Central United States. The algorithm is calibrated with the morning radiosonde sites embedded within the first VAS radiance field; then, entire moisture fields are calculated at all five observation times. Cloud contamination is removed by rejecting any pixel having a radiance less than the atmospheric brightness determined at the radiosonde sites.

Chesters, D.↗

Influence of liquid water and water vapor on antimisting kerosene (AMK)

Experiments have been performed to evaluate the compatibility of liquid water and water vapor with antimisting kerosenes (AMK) containing polymer additive FM-9 developed by Imperial Chemical Industries. This effort consists of the determination of water solubility in AMK, influence of water on restoration (degradation) of AMK, and effect of water on standard AMK quality control methods. The principal conclusions of this investigation are: (1) the uptake of water in AMK critically depends upon the degree of agitation and can be as high as 1300 ppm at 20 C, (2) more than 250 to 300 ppm of water in AMK causes an insoluble second phase to form. The amount of this second phase depends on fuel temperature, agitation, degree of restoration (degradation) and the water content of the fuel, (3) laboratory scale experiments indicate precipitate formation when water vapor comes in contact with cold fuel surfaces at a much lower level of water (125 to 150 ppm), (4) precipitate formation is very pronounced in these experiments where humid air is percolated through a cold fuel (-20 C), (5) laboratory tests further indicate that water droplet settling time is markedly reduced in AMK as compared to jet A, (6) limited low temperature testing down to -30 C under laboratory conditions indicates the formation of stable, transparent gels.

Yavrouian, A. H.↗

Remote sensing evidence for regolith water vapor sources on Mars

McCord et al. (1977) have presented earth-based photometric imaging data of an event associated with the 1973 dust storm on Mars. The initial dust cloud in Solis Lacus and two regions to the north and south appeared anomalously bright at blue wavelengths. Water frosts, hazes, and/or clouds were identified, and it was suggested that the water responsible for these findings may have originated from Solis Lacus. More recently, a more intensive review of the observational record of Mars was undertaken. Earth-based telescope observations and data from the Mariner and Viking missions have revealed that Solis Lacus has been a center of repeated activity. Persistent activity in the vicinity of Noachis-Hellespontus and in the border regions of Syrtis Major was also discovered. A review of the observations is provided and possible interpretations are discussed. The obtained results appear to support the original proposal that Solis Lacus may be a source of water vapor. Noachis-Hellespontus seems to be a similar vapor source

Huguenin, R. L.↗

First-order wetting transition at a liquid-vapor interface

Evidence from reflectance and contact angle measurements is presented that three-phase mixtures of i-C3H7OH-C7F14 exhibit a first-order wetting phase transition at the liquid-vapor interface at 38 C. Equilibration phenomena support this interpretation. Ellipsometry was used to measure the apparent thickness of the intruding layer in the three-phase mixture. At temperatures slightly above the wetting temperature T(w), the intruding layer's thickness is several hundred angstroms and its variation with temperature is extremely weak. Below T(w), three-phase contact can occur between the vapor and both the upper and lower liquid phases; one of the angles which characterizes this contact has a very simple temperature dependence. The thickness of the intruding layer, monitored as the solutions approached equilibrium, is found to depend quite weakly on the height spanned by the upper liquid phase in the vicinity of a first-order wetting transition.

Schmidt, J. W.↗

Low level water vapor fields from the VISSR Atmospheric Sounder (VAS) 'split window' channels

The use of the 11 and 12-micron IR-radiometer channels of the VISSR Atmosphere Sounder (VAS) on the GOES to detect water vapor in the lowest 300-400 mb of the troposphere is reported. An algorithm is developed to eliminate the background temperature, allowing the calculation of precipitable water (PW) over both land and water via a single-layer radiative model. This 'split-window' method is demonstrated in a case study, covering the US on July 13, 1981. PW values were calculated from five VAS images and compared with those from radiosonde data and surface measurements. It is shown that the VAS PW images have good resolution (15 km), reveal vivid, continuously evolving details, and differentiate deep, convection-supporting layers from shallow ones. PW ranged from 1.7 to 5.5 g/sq cm (+ or - 1.0 g/sq cm), in good agreement with other measurements. Since this method can detect mesoscale water-vapor fields in relatively clear air, it is considered of great potential value for numerical forecasting.

Robinson, W. D.↗

Convective-diffusive transport in vapor growth ampoules

Theoretical and experimental work on heat and mass transport in crystal growth by closed ampoule vapor transport is reviewed. It is shown that double-diffusive phenomena, together with the three-dimensional boundary conditions of real systems lead to a complexity of the transport modes that are beyond the reach of the simplifying models currently used in the materials preparation literature. Consequences of the new insights for earth-bound vapor transport and for optimization of future space experiments are discussed.

Rosenberger, F.↗

Ozone and water vapor monitoring using a ground-based lidar system

Measurements of atmospheric ozone and water vapor profiles obtained using a differential absorption lidar (DIAL) technique at Haute Provence Observatory are reported. The DIAL technique is based on the comparison of differences in attenuation in backscattered signals at wavelengths centered on strong absorptions or absorption lines of the species in question, and wavelengths corresponding to weaker or no absorption. The system in use is based on three lasers - a Nd:YAG Q-switched laser frequency doubled to emit at 532 nm, and two tunable narrowline dye lasers used to convert this emission into the IR or UV spectral regions. Ozone concentration profiles have been recorded up to a height of 30 km, and reveal large day-to-day variations in number density which were correlated with a decrease in tropopause height. Measurements of water vapor concentrations show a variability of the mixing ratio at heights up to 2.5 km representative of dynamic processes, and a variability above 2.5 km that is within the measurement error. Day-to-day variations in tropospheric mixing ratio were also observed.

Megie, G.↗

Remote measurements of ozone, water vapor and liquid water content, and vertical profiles of temperature in the lower troposphere

Several advanced atmospheric remote sensing systems developed at the Jet Propulsion Laboratory were demonstrated under various field conditions to determine how useful they would be for general use by the California Air Resources Board and local air quality districts. One of the instruments reported on is the Laser Absorption Spectrometer (LAS). It has a pair of carbon dioxide lasers with a transmitter and receiver and can be flown in an aircraft to measure the column abundance of such gases as ozone. From an aircraft, it can be used to rapidly survey a large region. The LAS is usually operated from an aircraft, although it can also be used at a fixed location on the ground. Some tests were performed with the LAS to measure ozone over a 2-km horizontal path. Another system reported on is the Microwave Atmospheric Remote Sensing System (MARS). It is tuned to microwave emissions from water vapor, liquid water, and oxygen molecules (for atmospheric temperature). It can measure water vapor and liquid water in the line-of-sight, and can measure the vertical temperature profile.

Grant, W. B.↗

Engineering correlations of variable-property effects on laminar forced convection mass transfer for dilute vapor species and small particles in air

A simple engineering correlation scheme is developed to predict the variable property effects on dilute species laminar forced convection mass transfer applicable to all vapor molecules or Brownian diffusing small particle, covering the surface to mainstream temperature ratio of 0.25 T sub W/T sub e 4. The accuracy of the correlation is checked against rigorous numerical forced convection laminar boundary layer calculations of flat plate and stagnation point flows of air containing trace species of Na, NaCl, NaOH, Na2SO4, K, KCl, KOH, or K2SO4 vapor species or their clusters. For the cases reported here the correlation had an average absolute error of only 1 percent (maximum 13 percent) as compared to an average absolute error of 18 percent (maximum 54 percent) one would have made by using the constant-property results.

Gokoglu, S. A.↗

Inversion Algorithms for Water Vapor Radiometers Operating at 20.7 and 31.4 Ghz

Eight water vapor radiometers (WVRs) were constructed as research and development tools to support the Advanced System Programs in the Deep Space Network and the Crustal Dynamics Project. These instruments are intended to operate at the stations of the Deep Space Network (DSN), various radio observatories, and obile facilities that participate in very long baseline interferometric (VLBI) experiments. It is expected that the WVRs will operate in a wide range of meteorological conditions. Several algorithms are discussed that are used to estimate the line-of-sight path delay due to water vapor and columnar liquid water rom the observed microwave brightness temperatures provided by the WVRs. In particular, systematic effects due to site and seasonal variations are examined. The accuracy of the estimation as indicated by a simulation calculation is approximately 0.3 cm for a noiseless WVR in clear and moderately cloudy weather. With a realistic noise model of WVR behavior, the inversion accuracy is approximately 0.6 cm.

Resch, G. M.↗