At least 1,567 records · Page 87

Reducing Xerostomia After Chemo-IMRT for Head-and-Neck Cancer: Beyond Sparing the Parotid Glands

Purpose: To assess whether, in addition to sparing the parotid glands (PGs), xerostomia after chemotherapy plus intensity-modulated radiotherapy (chemo-IMRT) for head-and-neck cancer is affected by reducing the dose to the other salivary glands. Patients and Methods: In a prospective study, 78 patients with Stage III-IV oropharynx/nasopharynx cancer underwent chemo-IMRT, with the aim of sparing the parts of the bilateral PGs, oral cavity (OC) containing the minor salivary glands, and contralateral submandibular gland (SMG) outside the target (when contralateral level I was not a target). Before therapy and periodically for 24 months, validated patient-reported xerostomia questionnaire (XQ) scores and observer-graded xerostomia scores were recorded. Also, the stimulated and unstimulated saliva was measured selectively from each of the PGs and SMGs. The mean OC doses served as surrogates of minor salivary gland dysfunction. Regression models assessed the XQ and observer-graded xerostomia predictors. Results: Statistically significant predictors of the XQ score on univariate analysis included the OC, PG, and SMG mean doses and the baseline XQ score, time since RT, and both stimulated and unstimulated PG saliva flow rates. Similar factors were statistically significant predictors of observer-graded xerostomia. The OC, PG, and SMG mean doses were moderately intercorrelated (r = 0.47-0.55). On multivariate analyses, after adjusting for the PG and SMG doses, the OC mean dose (p < .0001), interval from RT (p < .0001), and stimulated PG saliva (p < .0025) were significant predictors of the XQ scores and the OC mean dose and time for observer-graded xerostomia. Although scatter plots showed no thresholds, an OC mean dose of <40 Gy and contralateral SMG mean dose of <50 Gy were each associated with low patient-reported and observer-rated xerostomia at almost all post-therapy points. Conclusion: The PG, SMG, and OC mean doses were significant predictors of both patient-reported and observer-rated xerostomia after chemo-IMRT, with OC doses remaining significant after adjusting for the PG and SMG doses. These results support efforts to spare all the salivary glands by IMRT, beyond the PGs alone.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Nature of Standing Plasma Waves Following Fast Breakdown in Thunderstorms

Narrow bipolar events (NBEs) are produced by large-scale systems of streamer corona discharges that occur inside thunderstorms and radiate intensely at very-high frequencies. Here we examine 14 high-power NBEs recorded in Florida which are followed by a lasting oscillatory signal. We isolate the dominant frequencies of the oscillations using empirical mode decomposition methods, and cross-reference this information with the radiator size inferred from broadband interferometry. We conclude that the oscillations are evidence of a standing electromagnetic wave in the plasma cavity created by the preceding streamer system, that is, the cavity's fundamental mode with wavelength equal to twice the radiator length. Contrasting the dispersive and attenuation properties of these waves across several different events allows us to conclude that the cavity is filled with ions resulting in an average conductivity of 0.01–0.1 mS/m, which are left behind after the streamers decay via electron attachment to oxygen molecules.

58 GEOSCIENCES↗

Molecular electrostatic potentials by systematic molecular fragmentation

A simple method is presented for estimating the molecular electrostatic potential in and around molecules using systematic molecular fragmentation. This approach estimates the potential directly from the electron density. The accuracy of the method is established for a set of organic molecules and ions. The utility of the approach is demonstrated by estimating the binding energy of a water molecule in an internal cavity in the protein ubiquitin.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Efficient collection of single photons emitted from a trapped ion into a single-mode fiber for scalable quantum-information processing

Interference and coincidence detection of two photons emitted by two remote ions can lead to an entangled state, which is a critical resource for scalable quantum-information processing. Currently the success probabilities of experimental realizations of this protocol are mainly limited by low coupling efficiency of a photon emitted by an ion into a single-mode fiber. Here we consider two strategies to enhance the collection probability of a photon emitted from a trapped Yb{sup +} ion, using analytic methods that can be easily applied to other types of ions or neutral atoms. Our analysis shows that we can achieve fiber coupling efficiency of over 30% with an optical cavity made of a flat fiber tip and a spherical mirror. We also investigate ways to increase the fiber coupling efficiency using high-numerical-aperture optics, and show that collection probability of over 15% is possible with proper control of aberration.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Effect of inhomogeneous surface disorder on the superheating field of superconducting RF cavities

Recent advances in surface treatments of Niobium superconducting radio frequency (SRF) cavities have led to substantially increased Q-factors and maximum surface field. This poses theoretical challenges to identify the mechanisms responsible for such performance enhancements. We report theoretical results for the effects of inhomogeneous surface disorder on the superheating field --- the surface magnetic field above which the Meissner state is globally unstable. We find that inhomogeneous disorder, such as that introduced by infusion of Nitrogen into the surface layers of Niobium SRF cavities, can increase the superheating field above the maximum for superconductors in the clean limit or with homogeneously distributed disorder. Homogeneous disorder increases the penetration of screening current, but also suppresses the maximum supercurrent. Inhomogeneous disorder in the form of an impurity diffusion layer biases this trade-off by increasing the penetration of the screening currents into cleaner regions with larger critical currents, thus limiting the suppression of the screening current to a thin dirty region close to the surface. Our results suggest that the impurity diffusion layers play a role in enhancing the maximum accelerating gradient of Nitrogen treated Niobium SRF cavities.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Acclerator R&D for a Linear Collider

The goal of this project was to perform simulations of beam transport in linear colliders, with an emphasis on emittance dilution, spin polarization transport, and development and testing of beam based tuning algorithms. Our simulations are based on an existing object-oriented particle-tracking library, Bmad. To facilitate the efficient development of simulations, an accelerator design and analysis program based on Bmad has been developed called Tao (Tool for Accelerator Optics). The three beam-based alignment algorithms, Dispersion Free Steering, Ballistic Alignment (BA), and the Kubo Method have been implemented in Tao. We have studied the effects of magnet misalignments, BPM resolution, beam jitter, stray fields, BPM and steering magnet failure and the effects of various cavity shape wakefields. A parametric study has been conducted in the presence of the above types of errors for all three alignment algorithms. We find that BPM resolution has only modest impact on the effectiveness of beam based alignment. The DFS correction algorithm was found to be very robust in situations where there were BPM and/or steering magnet failures. The wakefields in the main linac are very weak and cause negligible emittance growth. Spin tracking was extended to study all accelerator components between the damping ring and the interaction point, including RF cavities and the helical undulator. We find that there is no significant depolarization in the RTML, main linac or beam delivery system and that the polarization is relatively insensitive to misalignment. We have developed an effective spin rotator. During the final year of the grant we exploited the computing power of our new linux cluster, along with the modeling codes that we had developed, to investigate damping ring physics and design, specifically as it relates to the CESR Test Accelerator project.

43 PARTICLE ACCELERATORS↗

Superconductive magnetic-field-trapping device

An apparatus which enables the establishment of a magnetic field in air that has the same intensity as the ones in ferromagnetic materials is described. The apparatus is comprised of a core of ferromagnetic material and is surrounded by a cylinder made of a material that has superconducting properties when cooled below a critical temperature. A method is provided for producing a magnetic field through the ferromagnetic core. The core can also be split and pulled apart when it is required that the center of the cavity be left empty.

Hildebrandt, A. F.↗

Users' manual for computer program for one-dimensional analysis of coupled-cavity traveling wave tubes

The use of the coupled cavity traveling wave tube for space communications has led to an increased interest in improving the efficiency of the basic interaction process in these devices through velocity resynchronization and other methods. To analyze these methods, a flexible, large signal computer program for use on the IBM 360/67 time-sharing system has been developed. The present report is a users' manual for this program.

Omalley, T. A.↗

Users' manual for computer program for three-dimensional analysis of coupler-cavity traveling wave tubes

The use of the coupled cavity traveling wave tube for space communications has led to an increased interest in improving the efficiency of the basic interaction process in these devices through velocity resynchronization and other methods. A flexible, three dimensional, axially symmetric, large signal computer program was developed for use on the IBM 370 time sharing system. A users' manual for this program is included.

Omalley, T. A.↗

Stability of the Halley cometosheath with resistivity and plasma motion

The MHD stability of the cometary inner sheath determined by the balance between the inward Lorentz body force and the outward ion-neutral drag force is investigated by numerically solving the wave equations which include resistivity, plasma motion and plasma pressure with the help of two-point boundary value method. The eigenvalues and the eigenfunctions are obtained numerically by treating the cometary inner sheath as a layer of finite thickness, bounded by the contact surface, that is, the diamagnetic cavity boundary. To gain insight into the problem, certain limiting cases of the wave equations are also discussed. The diamagnetic cavity boundary and the adjacent layer of about 100-km thickness of Comet Halley is found to be unstable. The effects of finite plasma pressure, dissociative recombination, mass loading due to photoionization, resistivity, and plasma motion are found to be stabilizing but are unable to quench the instability completely. Motion of the Halley ionopause has been confirmed by observations.

Srivastava, Krishna M.↗

Adaptive Beam Loading Compensation in Room Temperature Bunching Cavities

In this paper we present the design, simulation, and proof of principle results of an optimization based adaptive feedforward algorithm for beam-loading compensation in a high impedance room temperature cavity. We begin with an overview of prior developments in beam loading compensation. Then we discuss different techniques for adaptive beam loading compensation and why the use of Newton?s Method is of interest for this application. This is followed by simulation and initial experimental results of this method.

43 PARTICLE ACCELERATORS↗

Nonlinear optical frequency conversion using metamaterial arrays

A method of nonlinear wavelength generation uses a nonlinear optical medium. An input flux of pump energy is applied to one or more dielectric optical resonators. Each resonator has an optical cavity comprising the nonlinear optical medium. Each resonator has at least one Mie resonance that is excited by the input flux of pump energy. The pump energy causes the generation of converted light containing at least one converted component having a frequency attainable only through a non-linear process.

36 MATERIALS SCIENCE↗

Method for energy dither of a particle beam

A method for applying an energy dither to a charged particle beam in order to vary the wavelength of the charged particle beam. Bunches of charged particle beams are accelerated by cavities that are operated at a harmonic of the bunch repetition rate. One or more secondary radiofrequency accelerator cavities are added near the wiggler after the primary beam transport to apply a fluctuation between individual bunches with a pseudo-random distribution. The secondary radiofrequency accelerator cavities provide fine variations of the beam energy about a nominal operating point. Operating a free electron laser (FEL) with a 1% change in the electron beam energy via the secondary cavity will result in a 2% wavelength variation of the FEL output.

42 ENGINEERING↗

Ceramic matrix composite turbine nozzle shell and method of assembly

A ceramic matrix composite turbine nozzle includes a primary outer nozzle platform; a primary inner nozzle platform; and an airfoil-shaped body extending between the primary inner and primary outer nozzle platforms. The body includes core plies defining a cavity; composite wrap plies circumscribing the core plies and defining an airfoil shape; a secondary outer nozzle platform in contact with the primary outer nozzle platform; and a secondary inner nozzle platform in contact with the primary inner nozzle platform. Each composite wrap ply has two layers of unidirectional fibers oriented transverse to each other and has first and second longitudinal edges. The first and second longitudinal edges are cut into fingers, which are folded in a transverse direction away from a turbine nozzle longitudinal axis and are interleaved between platform plies to define the secondary inner nozzle platform and the secondary outer nozzle platform.

de Diego, Peter↗

WE-AB-BRA-11: Improved Imaging of Permanent Prostate Brachytherapy Seed Implants by Combining an Endorectal X-Ray Sensor with a CT Scanner

Purpose: To test feasibility of the use of a digital endorectal x-ray sensor for improved image resolution of permanent brachytherapy seed implants compared to conventional CT. Methods: Two phantoms simulating the male pelvic region were used to test the capabilities of a digital endorectal x-ray sensor for imaging permanent brachytherapy seed implants. Phantom 1 was constructed from acrylic plastic with cavities milled in the locations of the prostate and the rectum. The prostate cavity was filled a Styrofoam plug implanted with 10 training seeds. Phantom 2 was constructed from tissue-equivalent gelatins and contained a prostate phantom implanted with 18 strands of training seeds. For both phantoms, an intraoral digital dental x-ray sensor was placed in the rectum within 2 cm of the seed implants. Scout scans were taken of the phantoms over a limited arc angle using a CT scanner (80 kV, 120–200 mA). The dental sensor was removed from the phantoms and normal helical CT and scout (0 degree) scans using typical parameters for pelvic CT (120 kV, auto-mA) were collected. A shift-and add tomosynthesis algorithm was developed to localize seed plane location normal to detector face. Results: The endorectal sensor produced images with improved resolution compared to CT scans. Seed clusters and individual seed geometry were more discernable using the endorectal sensor. Seed 3D locations, including seeds that were not located in every projection image, were discernable using the shift and add algorithm. Conclusion: This work shows that digital endorectal x-ray sensors are a feasible method for improving imaging of permanent brachytherapy seed implants. Future work will consist of optimizing the tomosynthesis technique to produce higher resolution, lower dose images of 1) permanent brachytherapy seed implants for post-implant dosimetry and 2) fine anatomic details for imaging and managing prostatic disease compared to CT images. Funding: LSU Faculty Start-up Funding. Disclosure: XDR Radiography has loaned our research group the digital x-ray detector used in this work. CoI: None.

60 APPLIED LIFE SCIENCES↗

A finite element computational method for high Reynolds number laminar flows

A velocity-pressure integrated, mixed interpolation, Galerkin finite element method for the Navier-Stokes equations is presented. In the method, the velocity variables are interpolated using complete quadratic shape functions, and the pressure is interpolated using linear shape functions which are defined on a triangular element for the two-dimensional case and on a tetrahedral element for the three-dimensional case. The triangular element and the tetrahedral element are contained inside the complete bi- and tri-quadratic elements for velocity variables for two and three dimensional cases, respectively, so that the pressure is discontinuous across the element boundaries. Example problems considered include: a cavity flow of Reynolds numbers 400 through 10,000; a laminar backward facing step flow; and a laminar flow in a square duct of strong curvature. The computational results compared favorably with the finite difference computational results and/or experimental data available. It was found that the present method can capture the delicate pressure driven recirculation zones, that the method did not yield any spurious pressure modes, and that the method requires fewer grid points than the finite difference methods to obtain comparable computational results.

Kim, Sang-Wook↗

Method and apparatus for selectively annealing heterostructures using microwaves

The present invention discloses a process for selectively annealing heterostructures using microwaves. A heterostructure, comprised of a material having higher microwave absorption and a material having lower microwave absorption, is exposed to microwaves in the cavity. The higher microwave absorbing material absorbs the microwaves and selectively heats while the lower microwave absorbing material absorbs small amounts of microwaves and minimally heats. The higher microwave absorbing material is thereby annealed onto the less absorbing material which is thermally isolated.

Atwater, Harry A.↗

Method and apparatus for selectively annealing heterostructures using microwave

The present invention discloses a process for selectively annealing heterostructures using microwaves. A heterostructure, comprised of a material having higher microwave absorption and a material having lower microwave absorption, is exposed to microwaves in the cavity. The higher microwave absorbing material absorbs the microwaves and selectively heats while the lower microwave absorbing material absorbs small amounts of microwaves and minimally heats. The higher microwave absorbing material is thereby annealed onto the less absorbing material which is thermally isolated.

Atwater, Harry A.↗