Search NASA⌕ Search

SEARCH · Search NASA

Results for “characterization techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

NOVEL CHARACTERIZATION OF THE ELECTROPOLISHING OF NIOBIUM WITH SULFURIC AND HYDROFLUORIC ACID MIXTURES

Niobium surfaces are commonly electropolished in an effort to obtain optimally smooth surfaces for high-field SRF cavity applications. We report the first use of controlled electrochemical analysis techniques to characterize electropolishing of Nb in a sulfuric and hydrofluoric acid electrolyte. Through the use of a reference electrode we are able to clearly distinguish the anode, cathode polarization potentials as well as the electrolyte voltage drop that sum to the applied power supply voltage. We then separate the temperature and HF concentration dependence of each. We also report the first use of Electrochemical Impedance Spectroscopy (EIS) on this system. EIS results are consistent with a presence of a compact salt film at the Nb/electrolyte interface that is responsible for the limiting current. Microscopic understanding of the basic Nb EP mechanism is expected to provide an appropriate foundation with which to optimize the preparation of high-field niobium cavity surfaces. The implication of EIS for monitoring Nb surface during electropolishing shows this technology could be potentially used as a source of on-line feedback.

36 MATERIALS SCIENCE↗

Thin Film Microstructure of a Solution Processable Pyrene-Based Organic Semiconductor

Semiconducting 6,7,15,16-tetrakis(dodecylthio)quinoxalino[2',3':9,10]phenanthro[4,5-abc]phenazine (TQPP-12) has been synthesized as a candidate solution-processable semiconductor for organic electronics applications. We characterize the microstructure of TQPP-12 in films using a combination of polarized photon absorption spectroscopies (X-ray, vis, and infrared), X-ray diffraction, and scanning probe techniques. This characterization strategy allowed for the determination of molecular orientation and packing style within thin films of this complex molecule. The TQPP-12 molecules are arranged within layers, and the aromatic cores are separated from the alkane side chains. Both the core long axes and side chains are highly tilted with respect to surface normal, and the conjugated planes of the core are cofacially packed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Trace-gas sensing using the compliance voltage of an external cavity quantum cascade laser

Quantum cascade lasers (QCLs) are increasingly being used to detect, identify, and measure levels of trace gases in the air. External cavity QCLs (ECQCLs) provide a broadly-tunable infrared source to measure absorption spectra of chemicals and provide high detection sensitivity and identification confidence. Applications include detecting chemical warfare agents and toxic industrial chemicals, monitoring building air quality, measuring greenhouse gases for atmospheric research, monitoring and controlling industrial processes, analyzing chemicals in exhaled breath for medical diagnostics, and many more. Compact, portable trace gas sensors enable in-field operation in a wide range of platforms, including handheld units for use by first responders, fixed installations for monitoring air quality, and lightweight sensors for deployment in unmanned aerial vehicles (UAVs). We present experimental demonstration of a new chemical sensing technique based on intracavity absorption in an external cavity quantum cascade laser (ECQCL). This new technique eliminates the need for an infrared photodetector and gas cell by detecting the intracavity absorption spectrum in the compliance voltage of the laser device itself. To demonstrate and characterize the technique, we measure infrared absorption spectra of chemicals including water vapor and Freon-134a. Sub-ppm detection limits in one second are achieved, with the potential for increased sensitivity after further optimization. The technique enables development of handheld, high-sensitivity, and high-accuracy trace gas sensors for in-field use.

infrared spectroscopy, quantum cascade laser, trac↗

X-ray Laue Diffraction Microscopy in 3D at the Advanced Photon Source

Studies of materials on mesoscopic length-scales require a penetrating structural probe with submicron point-to-point spatial resolution. The principle research activities at beamline 34-ID-E of the Advanced Photon Source (APS) involve development of exciting new micro-/nano-diffraction techniques for characterization and microscopy in support of both applied engineering and fundamental materials research. Taking advantage of the high brightness of the source, advanced focusing mirrors, a novel depth profiling technique, and high-speed area detectors, three-dimensional scanning Laue diffraction microscopy provides detailed local structural information of crystalline materials, such as crystallographic orientation, orientation gradients, and strain tensors. It is general and applicable to single-crystal, polycrystalline, composite, deformed, and functionally graded materials. Applications include 3D diffraction investigations for a diverse and growing user community with interests in materials deformation, electro-migration, recrystallization, fatigue, solid-solution precipitation, high-pressure environments, and condensed matter physics.

43 PARTICLE ACCELERATORS↗

Synthesis and characterization of Ca-doped LaMnAsO

Here, we report on our attempt to hole-dope the antiferromagnetic semiconductor LaMnAsO by substitution of the La 3+ site by Ca 2+ . We use neutron and x-ray diffraction, magnetic susceptibility, and transport techniques to characterize polycrystalline (La 1–x Ca x )MnAsO samples prepared by solid-state reaction and find that the parent compound is highly resistant to substitution with an upper limit x ≤ 0.01. Magnetic susceptibility of the parent and the x = 0.002(x nom = 0.04) compounds indicate a negligible presence of magnetic impurities (i.e., MnO or MnAs). Rietveld analysis of neutron and x-ray diffraction data shows the preservation of both the tetragonal (P4/nmm) structure upon doping and the antiferromagnetic ordering temperature, T N = 355 ± 5 K.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Amazonian fog harbors viable microbes

Fog formation over tropical forests remains poorly characterized, despite its potential role in bioaerosol dispersion and ecosystem processes. Here, we analyzed fog samples collected at the Amazon Tall Tower Observatory using flow cytometry and culture-based techniques to characterize viable microbial communities. Microbial cell concentrations varied over an order of magnitude across 13 fog events, reaching up to 8 × 104 cells per ml of fog water. Flow cytometry consistently detected metabolically active cells, while culturing and mass spectrometry-based identification yielded eight viable bacterial species and seven fungal taxa. The bacteria Serratia marcescens, Ralstonia pickettii and Sphingomonas paucimobilis exhibited seasonal variations in prevalence. The fungal species identified were primarily mesophilic saprophytes and endophytes, commonly associated with soil and plant surfaces. Our findings indicate that fog harbors viable microbes, including Serratia marcescens and Ralstonia pickettii, which may imply a relevance of fog for microbial dispersal, colonization and nutrient cycling in the Amazon rainforest.

Godoi, Ricardo H. (ORCID:0000000247744870)↗

Characterization of Field-Aged EGR Cooler Deposits

Exhaust gas recirculation (EGR) cooler fouling has become a significant issue for compliance with NOx emissions standards. In order to better understand fouling mechanisms, eleven field-aged EGR coolers provided by seven different engine manufacturers were characterized using a suite of techniques. Microstructures were characterized using scanning electron microscopy (SEM) and optical microscopy following mounting the samples in epoxy and polishing. Optical microscopy was able to discern the location of hydrocarbons in the polished cross-sections. Chemical compositions were measured using thermal gravimetric analysis (TGA), differential thermal analysis (DTA), gas chromatography-mass spectrometry (GC-MS), x-ray photoelectron spectroscopy (XPS), energy dispersive spectroscopy (EDS) and X-ray diffraction (XRD). Mass per unit area along the length of the coolers was also measured. Despite coming from different sources and applications, many common features were observed in the cooler deposits including mud-cracking, hydrocarbon condensation near the metal surface, and erosion of the deposit. Differences and commonalities between the coolers will be discussed in the context of better understanding cooler fouling and ways to prevent it.

33 ADVANCED PROPULSION SYSTEMS↗

Developing techniques for crystal growth synthesis and characterization of rare earth-silicon-germanium magnetoresponsive alloys

In this study, a crystal growth technique was developed for the family of intermetallic, magnetoresponsive RE 5 (Si 1-x Ge x ) 4 alloys in order to access the intrinsic and anisotropic properties. Initial bulk properties measured on polycrystalline samples alluded to the properties being obscured or averaged and high-quality, well-characterized, single crystals would clarify this. Successful crystal growth led to development of oriented sample preparation techniques specific for the crystal structures (monoclinic and orthorhombic) and mechanical properties (hard and brittle) of these alloys, and customized for the various measurement techniques undertaken. Here we describe our journey, sometimes circuitous, from crystal growth to sample preparation and cite the scientific discoveries that came about as a result.

36 MATERIALS SCIENCE↗

Quantitative non-destructive evaluation of porous composite materials based on ultrasonic wave propagation

Two complementary ultrasonic techniques for characterizing porosity in fiber-reinforced composite laminates are evaluated. Five uniaxial graphite-fiber/epoxy-matrix composites having a range of 1 to 8 percent volume fraction of solid glass inclusions to model porosity were investigated. In one technique, signal loss was measured in transmission mode and slope of attenuation, obtained from the first order coefficient of a two-parameter polynomial fit about the center frequency of the useful bandwidth, was used as the ultrasonic parameter to characterize the porosity. The results of these transmission mode measurements displayed a good correlation between the volume fraction of porosity and the slope of attenuation. Integrated polar backscatter was used as a second ultrasonic parameter for the characterization of the porosity in these samples. A single transducer insonified the samples and measured the resulting backscatter at a polar angle of 30 deg with respect to the normal of the sample surface with the azimuthal angles centered at 0 deg with respect to the fiber orientation (i.e., along the fibers). Integrated polar backscatter also displayed good correlation with the volume fraction of porosity.

Miller, James G.↗

Comparison of Dislocation Characterization by Electron Channeling Contrast Imaging and Cross-Correlation Electron Backscattered Diffraction

The characterization and quantification of dislocations is predominately carried out using transmission electron microscopy (TEM). Nevertheless, the sample preparation necessary for TEM foils can be cumbersome and possibly introduce defects. Two other techniques for characterizing and quantifying dislocations are electron channeling contrast imaging (ECCI) and cross-correlation electron backscattered diffraction (CC-EBSD). ECCI is similar to TEM in that specific imaging (channeling or diffraction) conditions need to be established, but is carried out in a scanning electron microscope on bulk samples, resulting in less complex sample preparation. CC-EBSD measures subtle changes in orientation measured from EBSD patterns to calculate elastic strains and the Nye tensor to deduce and map the total geometrically necessary dislocation (GND) content. Furthermore, this work presented here compares the capabilities of ECCI and CC-EBSD to map dislocations generated from nanoindentation.

42 ENGINEERING↗

Companding technique for high dynamic range measurements using Gafchromic films

Purpose: To introduce a methodology to perform dose measurements using Gafchromic films which can span several decades of dose levels. Methods: The technique is based on a rescaling approach using different films irradiated at different dose levels. This is combined with a registration protocol correcting positioning and scaling factors for each film. The methodology is validated using TLD's for out-of-field doses. Furthermore, two examples are provided using the technique to characterize small sized radiosurgery cones and compared with measurements made with a pinpoint chamber. Results: Excellent agreement with TLD, planning systems and measurement was found. The superior resolution of the film technique was apparent. Conclusions: The authors have introduced a new technique allowing users to quantify very low doses in conjunction with commissioning measurements. The use of film also provides 2D information on beam characteristics in high resolution measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization Report on Fuels for NEAMS Model Variation

We have investigated the grain boundary scattering effect on the thermal transport behavior of uranium dioxide (UO 2 ). The polycrystalline samples having different grain sizes (0.125, 1.8, and 7.2 μm) have been prepared by spark plasma sintering technique and characterized by x-ray powder diffraction (XRD), scanning electron microscope (SEM), and Raman spectroscopy. The thermal transport properties (the thermal conductivity and thermoelectric power) have been measured in the temperature range 2-300 K and the results were analyzed in terms of various physical parameters contributing to the thermal conductivity in these materials in relation to grain-size. We show that thermal conductivity decreases systematically with lowering grain-size in the temperatures below 30 K, where the boundary scattering dominates the thermal transport. At higher temperatures more scattering processes are involved in the heat transport in these materials. We analyzed the results obtained using molecular dynamics (MD) calculations.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Time-windows-based filtering method for near-surface detection of leakage from geologic carbon sequestration sites

We use process-based modeling techniques to characterize the temporal features of natural biologically controlled surface CO{sub 2} fluxes and the relationships between the assimilation and respiration fluxes. Based on these analyses, we develop a signal-enhancing technique that combines a novel time-window splitting scheme, a simple median filtering, and an appropriate scaling method to detect potential signals of leakage of CO{sub 2} from geologic carbon sequestration sites from within datasets of net near-surface CO{sub 2} flux measurements. The technique can be directly applied to measured data and does not require subjective gap filling or data-smoothing preprocessing. Preliminary application of the new method to flux measurements from a CO{sub 2} shallow-release experiment appears promising for detecting a leakage signal relative to background variability. The leakage index of ?2 was found to span the range of biological variability for various ecosystems as determined by observing CO{sub 2} flux data at various control sites for a number of years.

54 ENVIRONMENTAL SCIENCES↗

A Study of undulator magnets characterization using the Vibrating Wire technique

The vibrating wire (VW) technique employs a stretched wire as a magnetic field sensor. Because of the wire's small diameter ({approx}0.1mm or smaller) and because the wire can be supported from outside the magnet, this technique is very appealing for field measurements in small gap/bore undulators with small good field regions and with limited access to the tested field. In addition, in the case of elliptical undulators in which Hall probe (HP) measurements can be affected by the planar Hall effect, VW technique can be used as an independent method to verify and supplement HP measurements. In this article we studied the potential of the VW technique for measurement of magnetic field errors and for prediction of beam trajectories in undulator magnets using a 3.8m long LCLS undulator as a test bench. Introducing calibrated magnetic field distortion at various locations, we measured the sensitivity and spatial resolution of the method. The method demonstrated 0.9mm spatial resolution at a distance up to a few meters and 0.37Gcm sensitivity to the field integral. To compare Hall probe and Vibrating wire measurements side-by-side, we measured field errors in an LCLS undulator previously characterized by Hall probe measurements. The field errors found with the Vibrating Wire technique appeared to be in good agreement with errors measured with the Hall probe. Beam trajectory distortions calculated from both data sets are also in a good agreement.

43 PARTICLE ACCELERATORS↗

Characterization of Tight Gas Reservoir Pore Structure Using USANS/SANS and Gas Adsorption Analysis

Small-angle and ultra-small-angle neutron scattering (SANS and USANS) measurements were performed on samples from the Triassic Montney tight gas reservoir in Western Canada in order to determine the applicability of these techniques for characterizing the full pore size spectrum and to gain insight into the nature of the pore structure and its control on permeability. The subject tight gas reservoir consists of a finely laminated siltstone sequence; extensive cementation and moderate clay content are the primary causes of low permeability. SANS/USANS experiments run at ambient pressure and temperature conditions on lithologically-diverse sub-samples of three core plugs demonstrated that a broad pore size distribution could be interpreted from the data. Two interpretation methods were used to evaluate total porosity, pore size distribution and surface area and the results were compared to independent estimates derived from helium porosimetry (connected porosity) and low-pressure N{sub 2} and CO{sub 2} adsorption (accessible surface area and pore size distribution). The pore structure of the three samples as interpreted from SANS/USANS is fairly uniform, with small differences in the small-pore range (< 2000 {angstrom}), possibly related to differences in degree of cementation, and mineralogy, in particular clay content. Total porosity interpreted from USANS/SANS is similar to (but systematically higher than) helium porosities measured on the whole core plug. Both methods were used to estimate the percentage of open porosity expressed here as a ratio of connected porosity, as established from helium adsorption, to the total porosity, as estimated from SANS/USANS techniques. Open porosity appears to control permeability (determined using pressure and pulse-decay techniques), with the highest permeability sample also having the highest percentage of open porosity. Surface area, as calculated from low-pressure N{sub 2} and CO{sub 2} adsorption, is significantly less than surface area estimates from SANS/USANS, which is due in part to limited accessibility of the gases to all pores. The similarity between N{sub 2} and CO{sub 2}-accessible surface area suggests an absence of microporosity in these samples, which is in agreement with SANS analysis. A core gamma ray profile run on the same core from which the core plug samples were taken correlates to profile permeability measurements run on the slabbed core. This correlation is related to clay content, which possibly controls the percentage of open porosity. Continued study of these effects will prove useful in log-core calibration efforts for tight gas.

03 NATURAL GAS↗

Review—Electrolytic Metal Atoms Enabled Manufacturing of Nanostructured Sensor Electrodes

Sensing materials play a key role in the successful implementation of electrochemical sensors, and nanotechnology has emerged as an important and rapidly growing field for stimulating the innovation of high-performance sensors. The fabrication, characterization, and evaluation of the nanostructured electrodes are therefore a focus of this field. Compared to a variety of dry and wet technologies which have been extensively developed for this purpose, electrochemical methods are typically convenient, highly effective, and potentially low-cost for the production of different nanostructures. This minireview is designed to introduce a unique electrochemical method - electrolytic metal-atom enabled manufacturing (EM 2 ) and its application in electrochemical sensors. The EM 2 technique employs electrolytic metal atoms generated from their corresponding salt precursor as a tool to nanostructure a wide range of substrate electrodes used in electrochemical sensors, based on a one-pot electrochemical deposition and dissolution of the metal atoms in the same electrolyte bath. Briefly, the metal atoms are electrodeposited on a substrate electrode during the cathode reduction, and they are selectively removed from the substrate during the subsequent anode oxidation. Because of the interactions between the electrolytic metal atoms and the substrate atoms, the repetitive electrodeposition and dissolution of the former on the substrate enable the nanostructuration of the substrate, particularly within its surface layers. The nanostructured electrodes have demonstrated very attractive performance for the determination of numerous analytes, such as high sensitivity and selectivity, high interference tolerance, and low detection limits. However, the EM 2 technique and the application of the resulting nanostructured electrodes in electrochemical sensors and beyond have still been very limitedly investigated. In order to bring the community from academic, industries, agencies, and customers together to develop the EM 2 technique and advance electrochemical sensor systems, this minireview will introduce the thermodynamic and kinetic fundamentals of this technique, the characterization of resulting nanostructures, the analysis of their electrochemical behavior, and the implementation of this technique for the development of advanced sensor electrodes. Finally, an outlook with a focus on further research areas is provided.

Jiang, Junhua (ORCID:0000000324379812)↗

Characterization of nanostructured iron selenide thin films grown by chemical route at room temperature

Highlights: ► Nanostructured FeSe thin films were successfully synthesized at room temperature by CBD method. ► The XRD and EDAX characterization confirms nanocrystalline nature of FeSe. ► The SEM and AFM show microporous morphology with nanorods and nanoplates of FeSe. -- Abstract: Iron selenide thin films have been deposited onto glass substrates by using chemical bath deposition technique. Structural characterization of iron selenide thin films was carried out by means of X-ray diffraction and Fourier transforms infrared spectrum. The morphological characterization of FeSe thin film was carried out using scanning electron microscopy and atomic force microscopy, which revealed porous grain morphology of FeSe with some nano rectangular rods and plates grown on it. The as-deposited thin films exhibited optical band gap energy 2.60 eV. The as deposited FeSe thin films are semiconducting in nature with p-type electrical conductivity. The room temperature electrical resistivity is of the order of 1.1 × 10{sup 5} Ω-cm with activation energy 0.26 and 0.95 eV, respectively, in low and high temperature region.

36 MATERIALS SCIENCE↗