Search NASA⌕ Search

SEARCH · Search NASA

Results for “code verification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

MCNP(TM) Release 6.1.1 beta: Creating and Testing the Code Distribution

This report documents the preparations for and testing of the production release of MCNP6™1.1 beta through RSICC at ORNL. It addresses tests on supported operating systems (Linux, MacOSX, Windows) with the supported compilers (Intel, Portland Group and gfortran). Verification and Validation test results are documented elsewhere. This report does not address in detail the overall packaging of the distribution. Specifically, it does not address the nuclear and atomic data collection, the other included software packages (MCNP5, MCNPX and MCNP6) and the collection of reference documents.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Validation of ORIGEN for VVER-440 Spent Fuel with Application to Fork Detector Safeguards Measurements

The US Department of Energy National Nuclear Security Administration and the European Atomic Energy Community (Euratom) are collaborating with the Radiation and Nuclear Safety Authority in Finland to assess spent fuel verification methods for potential application to measurements at the planned spent fuel encapsulation plant and geological repository prior to final disposal in Finland. The fork detector (FDET) used to measure the neutron and gamma radiation from a given spent fuel assembly is an existing technology widely used by the International Atomic Energy Agency (IAEA) and Euratom for the safeguards verification of spent fuel operator declaration. Recently, an FDET data analysis software, referred to as the ORIGEN module, was developed and incorporated into the IAEA/Euratom Integrated Review and Analysis Program. This module uses the ORIGEN burnup code to calculate the nuclide concentrations and the neutron and gamma source terms in the spent fuel based on operator declarations. Then, to predict the expected FDET signals for a given fuel assembly, the module combines the source terms calculated by ORIGEN with FDET response functions that were pre-generated using MCNP models. The inspector can compare the calculated signals to the measured values in real time to identify possible anomalies in fuel assembly’s operator declaration, integrity, or measurement. In this work, the capability of the ORIGEN module was extended from application to typical light water reactor fuels to use for VVER-440 assembly types. The accuracy of ORIGEN for this type of fuel assembly calculations was assessed by comparing calculated nuclide concentrations against destructive assay measurements for VVER-440 spent fuel. The performance of the ORIGEN module for FDET safeguards verification in routine inspections was assessed using FDET measurement data for 13 spent VVER-440 assemblies that were measured at the Loviisa Nuclear Power Plant in Finland, by comparing the calculated signals to the measured quantities. The results show that the calculated FDET neutron and gamma detector signals are generally within 12% of the measurements except for one assembly. Thus, these results are applicable to future safeguards verification in the planned Finland encapsulation plant, such as for passive neutron albedo reactivity safeguards measurements.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

SU-E-T-36: A GPU-Accelerated Monte-Carlo Dose Calculation Platform and Its Application Toward Validating a ViewRay Beam Model

Purpose: To build a fast, accurate and easily-deployable research platform for Monte-Carlo dose calculations. We port the dose calculation engine PENELOPE to C++, and accelerate calculations using GPU acceleration. Simulations of a Co-60 beam model provided by ViewRay demonstrate the capabilities of the platform. Methods: We built software that incorporates a beam model interface, CT-phantom model, GPU-accelerated PENELOPE engine, and GUI front-end. We rewrote the PENELOPE kernel in C++ (from Fortran) and accelerated the code on a GPU. We seamlessly integrated a Co-60 beam model (obtained from ViewRay) into our platform. Simulations of various field sizes and SSDs using a homogeneous water phantom generated PDDs, dose profiles, and output factors that were compared to experiment data. Results: With GPU acceleration using a dated graphics card (Nvidia Tesla C2050), a highly accurate simulation – including 100*100*100 grid, 3×3×3 mm3 voxels, <1% uncertainty, and 4.2×4.2 cm2 field size – runs 24 times faster (20 minutes versus 8 hours) than when parallelizing on 8 threads across a new CPU (Intel i7-4770). Simulated PDDs, profiles and output ratios for the commercial system agree well with experiment data measured using radiographic film or ionization chamber. Based on our analysis, this beam model is precise enough for general applications. Conclusions: Using a beam model for a Co-60 system provided by ViewRay, we evaluate a dose calculation platform that we developed. Comparison to measurements demonstrates the promise of our software for use as a research platform for dose calculations, with applications including quality assurance and treatment plan verification.

60 APPLIED LIFE SCIENCES↗

Cable SGEMP Code Validation Study

This report compared data taken on the Modular Bremsstrahlung Simulator using copper jacketed (cujac) cables with calculations using the RHSD-RA Cable SGEMP analysis tool. The tool relies on CEPXS/ONBFP to perform radiation transport in a series of 1D slices through the cable, and then uses a Green function technique to evaluate the expected current drive on the center conductor. The data were obtained in 2003 as part of a Cabana verification and validation experiment using 1-D geometries, but were not evaluated until now. The agreement between data and model is not adequate unless gaps between the dielectric and outer conductor (ground) are assumed, and these gaps are large compared with what is believed to be in the actual cable.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Generative diffusion model surrogates for mechanistic agent-based biological models

Mechanistic, multicellular, agent-based models are commonly used to investigate tissue, organ, and organism-scale biology at single-cell resolution. The Cellular-Potts Model (CPM) is a powerful and popular framework for developing and interrogating these models. CPMs become computationally expensive at large space- and time- scales making application and investigation of developed models difficult. Surrogate models may allow for the accelerated evaluation of CPMs of complex biological systems. However, the stochastic nature of these models means each set of parameters may give rise to different model configurations, complicating surrogate model development. In this work, we leverage denoising diffusion probabilistic models (DDPMs) to train a generative AI surrogate of a CPM used to investigate in vitro vasculogenesis. We describe the use of an image classifier to learn the characteristics that define unique areas of a 2-dimensional parameter space. We then apply this classifier to aid in surrogate model selection and verification. Our CPM model surrogate generates model configurations 20,000 timesteps ahead of a reference configuration and demonstrates approximately a 22x reduction in computational time as compared to native code execution. Our work represents a step towards the implementation of DDPMs to develop digital twins of stochastic biological systems.

97 MATHEMATICS AND COMPUTING↗

SU-G-IeP2-04: Dosimetric Accuracy of a Monte Carlo-Based Tool for Cone-Beam CT Organ Dose Calculation: Validation Against OSL and XRQA2 Film Measurements

Purpose: The intensive use of Cone-Beam Computed Tomography (CBCT) during radiotherapy treatments raise some questions about the dose to healthy tissues delivered during image acquisitions. We hence developed a Monte Carlo (MC)-based tool to predict doses to organs delivered by the Elekta XVI kV-CBCT. This work aims at assessing the dosimetric accuracy of the MC tool, in all tissue types. Methods: The kV-CBCT MC model was developed using the PENELOPE code. The beam properties were validated against measured lateral and depth dose profiles in water, and energy spectra measured with a CdTe detector. The CBCT simulator accuracy then required verification in clinical conditions. For this, we compared calculated and experimental dose values obtained with OSL nanoDots and XRQA2 films inserted in CIRS anthropomorphic phantoms (male, female, and 5-year old child). Measurements were performed at different locations, including bone and lung structures, and for several acquisition protocols: lung, head-and-neck, and pelvis. OSLs and film measurements were corrected when possible for energy dependence, by taking into account for spectral variations between calibration and measurement conditions. Results: Comparisons between measured and MC dose values are summarized in table 1. A mean difference of 8.6% was achieved for OSLs when the energy correction was applied, and 89.3% of the 84 dose points were within uncertainty intervals, including those in bones and lungs. Results with XRQA2 are not as good, because incomplete information about electronic equilibrium in film layers hampered the application of a simple energy correction procedure. Furthermore, measured and calculated doses (Fig.1) are in agreement with the literature. Conclusion: The MC-based tool developed was validated with an extensive set of measurements, and enables the organ dose calculation with accuracy. It can now be used to compute and report doses to organs for clinical cases, and also to drive strategies to optimize imaging protocols.

60 APPLIED LIFE SCIENCES↗

Tools and Tool Support for the Exascale Era

The goal of this paper is to highlight the challenges in providing scalable tool support on exascale class machines and to identify key research and development needs as well as opportunities to meet these challenges. In this context we define tool support very broadly as software that helps programmers to understand, optimize and fix their codes as well as software that facilitates interaction between application, run-time, and hardware. This includes tools for performance analysis, static and run-time optimization, debugging, correctness verification and program transformation. This paper is intended as background material for the ASC exascale workshop, held in March 2011 in San Francisco, to stimulate discussion both within the tools area and across working groups. Further, this paper targets both the issues and requirements users have on tools in the exascale era as well as the requirements that need to be fulfilled by exascale systems to build scalable tools.

97 MATHEMATICS AND COMPUTING↗

User Manual for MC 2 -3 Gamma Library Generation

This report provides the documentation for the revised procedure to generate the MC 2 -3 gamma library with the latest versions of PreGAMMA and GenGAMMA which have recently been updated to fix the program errors and inconsistent data processing for some isotopes identified in a recent verification and validation study of the MC 2 -3 gamma library. A few associated errors associated with gamma processing were also identified and fixed in the MC 2 -3 code. Addressing the changes in MC 2 -3, the procedure to generate the PMATRX and GAMISO datasets is discussed as well. The input data of PreGAMMA and GenGAMMA are discussed in detail using sample input data. In addition, the structure and formats of the MC 2 -3 gamma library are provided in detail.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Overview of the Tolerance Limit Calculations with Application to TSURFER

To establish confidence in the results of computerized physics models, a key regulatory requirement is to develop a scientifically defendable process. The methods employed for confidence, characterization, and consolidation, or C3, are statistically involved and are often accessible only to avid statisticians. This manuscript serves as a pedagogical presentation of the C3 process to all stakeholders—including researchers, industrial practitioners, and regulators—to impart an intuitive understanding of the key concepts and mathematical methods entailed by C3. The primary focus is on calculation of tolerance limits, which is the overall goal of the C3 process. Tolerance limits encode the confidence in the calculation results as communicated to the regulator. Understanding the C3 process is especially critical today, as the nuclear industry is considering more innovative ways to assess new technologies, including new reactor and fuel concepts, via an integrated approach that optimally combines modeling and simulation and minimal targeted validation experiments. This manuscript employs intuitive, analytical, numerical, and visual representations to explain how tolerance limits may be calculated for a wide range of configurations, and it also describes how their values may be interpreted. Various verification tests have been developed to test the calculated tolerance limits and to help delineate their values. The manuscript demonstrates the calculation of tolerance limits for TSURFER, a computer code developed by the Oak Ridge National Laboratory for criticality safety applications. The goal is to evaluate the tolerance limit for TSURFER-determined criticality biases to support the determination of upper, subcritical limits for regulatory purposes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Eucalyptus – An Analysis Suite for Fault Trees with Uncertainty Quantification

Eucalyptus is a novel code developed at Lawrence Livermore National Laboratory to incorporate uncertainty quantification into Fault Tree Analysis (FTA). This tool addresses the challenge of imperfect knowledge in “grey-box” systems by allowing analysts to incorporate and propagate uncertainty from component-level assessments to system-level effects. Eucalyptus facilitates a consistent evaluation of the impact of subject matter expert judgment and knowledge gaps on overall system response by Monte Carlo generation of possible system fault trees, sampling probabilities of the existence of subsystems and components. Here, the code supports the specification of fault trees through text and allows export to various formats, including auto-generated images, easing analysis and reducing errors. It has undergone extensive verification testing, demonstrating its reliability and readiness for deployment, and leverages on-node parallelism for rapid analysis. Example analyses are shown that include the identification of system failure paths and quantification of the value of further information about system components.

Fault Tree Analysis↗

Discrete Spring Model for Predicting Delamination Growth in Z-Fiber Reinforced DCB Specimens

Beam theory analysis was applied to predict delamination growth in DCB specimens reinforced in the thickness direction with pultruded pins, known as Z-fibers. The specimen arms were modeled as cantilever beams supported by discrete springs, which were included to represent the pins. A bi-linear, irreversible damage law was used to represent Z-fiber damage, the parameters of which were obtained from previous experiments. Closed-form solutions were developed for specimen compliance and displacements corresponding to Z-fiber row locations. A solution strategy was formulated to predict delamination growth, in which the parent laminate mode I fracture toughness was used as the criterion for delamination growth. The solution procedure was coded into FORTRAN 90, giving a dedicated software tool for performing the delamination prediction. Comparison of analysis results with previous analysis and experiment showed good agreement, yielding an initial verification for the analytical procedure.

Ratcliffe, James G.↗

Discrete Spring Model for Predicting Delamination Growth in Z-Fiber Reinforced DCB Specimens

Beam theory analysis was applied to predict delamination growth in Double Cantilever Beam (DCB) specimens reinforced in the thickness direction with pultruded pins, known as Z-fibers. The specimen arms were modeled as cantilever beams supported by discrete springs, which were included to represent the pins. A bi-linear, irreversible damage law was used to represent Z-fiber damage, the parameters of which were obtained from previous experiments. Closed-form solutions were developed for specimen compliance and displacements corresponding to Z-fiber row locations. A solution strategy was formulated to predict delamination growth, in which the parent laminate mode I critical strain energy release rate was used as the criterion for delamination growth. The solution procedure was coded into FORTRAN 90, giving a dedicated software tool for performing the delamination prediction. Comparison of analysis results with previous analysis and experiment showed good agreement, yielding an initial verification for the analytical procedure.

Ratcliffe, James G.↗

NREL Hydrogen Sensor Testing Laboratory

The NREL Sensor Laboratory supports the HFTO's mission for the safe and efficient implementation of hydrogen as an energy carrier. Sensors are a critical element for a facility safety system by providing an early indication of unintended releases. Sensors can be used in process control applications (e.g., FQ verification). The Sensor Laboratory provides developers and end-users with an unbiased resource to validate sensor performance to application requirements. The Sensor Laboratory facilitates deployment through support of codes and standards development and safety research. The Sensor Laboratory supports advanced strategies for early leak detection.

detection↗

Calculating infinite-medium {alpha}-eigenvalue spectra with a transition rate matrix method

The time-dependent behavior of the energy spectrum in neutron transport was investigated with a formulation, based on continuous-time Markov processes, for computing {alpha}-eigenvalues and eigenvectors in an infinite medium. For this, a research Monte Carlo code called TORTE was created and used to estimate elements of a transition rate matrix. TORTE is capable of using both multigroup and continuous-energy nuclear data, and verification was performed. Eigenvalue spectra for infinite homogeneous mixtures were obtained and an eigenfunction expansion was used to investigate transient behavior of the neutron energy spectrum. (authors)

97 MATHEMATICS AND COMPUTING↗

Development of MELCOR 2.1 Guidance Report for LPF Applications

A complex nuclear facility includes several pathways that can transport accidentally released materials throughout the facility and potentially to the exterior environment. To model and estimate material transport and possible release as a source term from a U.S. Department of Energy (DOE) nuclear facility requires proficiency in applying simulation tools, such as the MELCOR code. DOE has designated MELCOR version 1.8.5, an obsolete version, as a DOE Tool Box code in its Central Registry. A leak path factor (LPF) guidance report written in 2004 did not include experimental validation data. Using an obsolete version of MELCOR requires additional verification and validations, which may be cost prohibitive. Without any developer support and lack of experimental data validation, it is difficult to justify to regulators that the calculated source term with the obsolete version of MELCOR from the facility is accurate and defensible. The goal of this work is to replace the obsolete guidance report with MELCOR 2.1 with experimental validations. In this paper, we will present our approach to develop a MELCOR 2.1 guidance report for LPF applications. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Analog neutron transport for nuclear instrumentation applications with the Monte-Carlo code TRIPOLI-4 - Paper 3

Monte-Carlo codes simulating particle transport usually make use of well-known variance reduction techniques, leading to more efficient simulations. Even in configurations which do not deal with deep-penetration, some of these techniques, such as the implicit capture, are actually often used by default. The statistical weight of the simulated particles is then modified in order to take into account the modification of the sampling without introducing any bias in the estimation process. For instance, the implicit capture decreases the statistical weight of the particles at each collision, whereas the sampling of a single outgoing particle increases this statistical weight in case of scattering reactions producing multiple neutrons. In addition, Russian roulette and splitting operations, which are usually also played at each collision, lead to other modifications of the statistical weights. As a result, Monte-Carlo codes provide particle histories that are valid on average, but collect statistical weights which differ from 1, when tallying the estimation of the quantities of interest. Yet, some nuclear instrumentation calculations inherently need to work with statistical weights equal to 1, since either individual events have to be collected (such as the arrival of a particle at a detector, the measurement of a time of flight, etc), or the coincidence of events or also correlations between individual events have to be taken into account. To address these specific applications with Monte-Carlo simulation codes, users need a full analog simulation mode. The continuous-energy Monte-Carlo code TRIPOLI4{sup R} is mainly dedicated to shielding, reactor physics and criticality safety calculations. Its capabilities have recently been extended to widen its use to nuclear instrumentation with the possibility of γ-spectrometry calculations and the simulation of photonuclear reactions for instance. Other features needed by nuclear instrumentation applications have been available in TRIPOLI-4 for a long time, such as the sampling of the time variable and the possibility of tallying in a time grid for most of the available tallies (fluxes, reaction rates, dose equivalent rates, energy depositions, etc). In TRIPOLI-4, the transport between two consecutive collisions is analog if no variance reduction technique is requested by the user to handle deep-penetration configurations. However, up to the version 9 of the code, the collision itself is sampled in a non-analog way. This paper presents a first implementation of a full analog neutron transport mode in TRIPOLI-4, preliminary verification results and an application of this functionality to the simulation of the Nucifer detector located in Saclay, France. It should be noted that only neutron transport is dealt with in this work and that all nuclear data come from JEFF-3.1.1 or ENDF/B-VII.0 evaluations, including fission data when needed. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

SAPHIRE 8 Software Independent Verification and Validation Plan

SAPHIRE 8 is being developed with a phased or cyclic iterative rapid application development methodology. Due to this approach, a similar approach is being taken for the IV&V activities on each vital software object. The IV&V plan is structured around NUREG/BR-0167, “Software Quality Assurance Program and Guidelines,” February 1993. The Nuclear Regulatory Research Office Instruction No.: PRM-12, “Software Quality Assurance for RES Sponsored Codes,” March 26, 2007 specifies that RES-sponsored software is to be evaluated against NUREG/BR-0167. Per the guidance in NUREG/BR-0167, SAPHIRE is classified as “Level 1.” Level 1 software corresponds to technical application software used in a safety decision.

99 GENERAL AND MISCELLANEOUS↗

SU-E-T-384: Experimental Verification of a Monte Carlo Linear Accelerator Model Using a Radiochromic Film Stack Dosimeter

Purpose: To experimentally verify a Monte Carlo (MC) linear accelerator model for the simulation of intensity-modulated radiation therapy (IMRT) treatments of moving targets. Methods: A Varian Clinac™ 21EX linear accelerator was modeled using the EGSnrc user code BEAMnrc. The mean energy, radial-intensity distribution, and divergence of the electron beam incident on the bremsstrahlung target were adjusted to achieve agreement between simulated and measured percentage-depth-dose and transverse field profiles for a 6 MV beam. A seven-field step-and-shoot IMRT lung procedure was prepared using Varian Eclipse™ treatment planning software. The plan was delivered using a Clinac™ 21EX linear accelerator and measured with a Gafchromic™ EBT2 film stack dosimeter (FSD) in two separate static geometries: within a cylindrical water-equivalent-plastic phantom and within an anthropomorphic chest phantom. Two measurements were completed in each setup. The dose distribution for each geometry was simulated using the EGSnrc user code DOSXYZnrc. MC geometries of the treatment couch, cylindrical phantom, and chest phantom were developed by thresholding CT data sets using MATLAB™. The FSD was modeled as water. The measured and simulated dose distributions were normalized to the median dose within the FSD. Results: Using an electron beam with a mean energy of 6.05 MeV, a Gaussian radial-intensity distribution with a full width at half maximum of 1.5 mm, and a divergence of 0°, the measured and simulated dose profiles agree within 1.75% and 1 mm. Measured and simulated dose distributions within both the cylindrical and chest phantoms agree within 3% over 94% of the FSD volume. The overall uncertainty in the FSD measurements is 3.1% (k=1). Conclusion: MC simulations agree with FSD measurements within measurement uncertainty, thereby verifying the accuracy of the linear accelerator model for the simulation of IMRT treatments of static geometries. The experimental verification will be extended to treatments of targets undergoing three-dimensional motion.

60 APPLIED LIFE SCIENCES↗