Search NASA⌕ Search

SEARCH · Search NASA

Results for “depth profiling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

High-Frequency Focused Water-Coupled Ultrasound Used for Three-Dimensional Surface Depression Profiling

To interface with other solids, many surfaces are engineered via methods such as plating, coating, and machining to produce a functional surface ensuring successful end products. In addition, subsurface properties such as hardness, residual stress, deformation, chemical composition, and microstructure are often linked to surface characteristics. Surface topography, therefore, contains the signatures of the surface and possibly links to volumetric properties, and as a result serves as a vital link between surface design, manufacturing, and performance. Hence, surface topography can be used to diagnose, monitor, and control fabrication methods. At the NASA Glenn Research Center, the measurement of surface topography is important in developing high-temperature structural materials and for profiling the surface changes of materials during microgravity combustion experiments. A prior study demonstrated that focused air-coupled ultrasound at 1 MHz could profile surfaces with a 25-m depth resolution and a 400-m lateral resolution over a 1.4-mm depth range. In this work, we address the question of whether higher frequency focused water-coupled ultrasound can improve on these specifications. To this end, we employed 10- and 25-MHz focused ultrasonic transducers in the water-coupled mode. The surface profile results seen in this investigation for 25-MHz water-coupled ultrasound, in comparison to those for 1-MHz air-coupled ultrasound, represent an 8 times improvement in depth resolution (3 vs. 25 m seen in practice), an improvement of at least 2 times in lateral resolution (180 vs. 400 m calculated and observed in practice), and an improvement in vertical depth range of 4 times (calculated).

Roth, Don J.↗

Dosimetric verification of a commercial Monte Carlo treatment planning system (VMC++) for a 9 MeV electron beam

The aim of this work was to evaluate the performance of the voxel-based Monte Carlo algorithm implemented in the commercial treatment planning system ONCENTRA MASTERPLAN for a 9 MeV electron beam produced by a linear accelerator Varian Clinac 2100 C/D. In order to realize an experimental verification of the computed data, three different groups of tests were planned. The first set was performed in a water phantom to investigate standard fields, custom inserts, and extended treatment distances. The second one concerned standard field, irregular entrance surface, and oblique incidence in a homogeneous PMMA phantom. The last group involved the introduction of inhomogeneities in a PMMA phantom to simulate high and low density materials such as bone and lung. Measurements in water were performed by means of cylindrical and plane-parallel ionization chambers, whereas measurements in PMMA were carried out by the use of radiochromic films. Point dose values were compared in terms of percentage difference, whereas the gamma index tool was used to perform the comparison between computed and measured dose profiles, considering different tolerances according to the test complexity. In the case of transverse scans, the agreement was searched in the plane formed by the intersection of beam axis and the profile (2D analysis), while for percentage depth dose curves, only the beam axis was explored (1D analysis). An excellent agreement was found for point dose evaluation in water (discrepancies smaller than 2%). Also the comparison between planned and measured dose profiles in homogeneous water and PMMA phantoms showed good results (agreement within 2%-2 mm). Profile evaluation in phantoms with internal inhomogeneities showed a good agreement in the case of ''lung'' insert, while in tests concerning a small ''bone'' inhomogeneity, a discrepancy was particularly evidenced in dose values on the beam axis. This is due to the inaccurate geometrical description of the phantom that is linked to the calculation voxel size, a feature over which the user has no control.

61 RADIATION PROTECTION AND DOSIMETRY↗

Implantation of sodium ions into germanium

The donor properties of Na atoms introduced by ion implantation into p-Ge with the resistivity 20-40 {Omega} cm are established for the first time. Na profiles implanted into Ge (the energies 70 and 77 keV and the doses (0.8, 3, 30) Multiplication-Sign 10{sup 14} cm{sup -2}) are studied. The doses and annealing temperatures at which the thermoprobe detects n-type conductivity on the sample surface are established. After implantation, the profiles exhibit an extended tail. The depth of the concentration maximum is in good agreement with the calculated mean projected range of Na ions R{sub p}. Annealing for 30 min at temperatures of 250-700 Degree-Sign C brings about a redistribution of Na atoms with the formation of segregation peaks at a depth, which is dependent on the ion dose, and is accompanied by the diffusion of Na atoms to the surface with subsequent evaporation. After annealing at 700 Degree-Sign C less than 7% of the implanted ions remain in the matrix. The shape of the profile tail portions measured after annealing at temperatures 300-400 Degree-Sign C is indicative of the diffusion of a small fraction of Na atoms into the depth of the sample.

36 MATERIALS SCIENCE↗

A pencil beam algorithm for helium ion beam therapy

Purpose: To develop a flexible pencil beam algorithm for helium ion beam therapy. Dose distributions were calculated using the newly developed pencil beam algorithm and validated using Monte Carlo (MC) methods. Methods: The algorithm was based on the established theory of fluence weighted elemental pencil beam (PB) kernels. Using a new real-time splitting approach, a minimization routine selects the optimal shape for each sub-beam. Dose depositions along the beam path were determined using a look-up table (LUT). Data for LUT generation were derived from MC simulations in water using GATE 6.1. For materials other than water, dose depositions were calculated by the algorithm using water-equivalent depth scaling. Lateral beam spreading caused by multiple scattering has been accounted for by implementing a non-local scattering formula developed by Gottschalk. A new nuclear correction was modelled using a Voigt function and implemented by a LUT approach. Validation simulations have been performed using a phantom filled with homogeneous materials or heterogeneous slabs of up to 3 cm. The beams were incident perpendicular to the phantoms surface with initial particle energies ranging from 50 to 250 MeV/A with a total number of 10{sup 7} ions per beam. For comparison a special evaluation software was developed calculating the gamma indices for dose distributions. Results: In homogeneous phantoms, maximum range deviations between PB and MC of less than 1.1% and differences in the width of the distal energy falloff of the Bragg-Peak from 80% to 20% of less than 0.1 mm were found. Heterogeneous phantoms using layered slabs satisfied a {gamma}-index criterion of 2%/2mm of the local value except for some single voxels. For more complex phantoms using laterally arranged bone-air slabs, the {gamma}-index criterion was exceeded in some areas giving a maximum {gamma}-index of 1.75 and 4.9% of the voxels showed {gamma}-index values larger than one. The calculation precision of the presented algorithm was considered to be sufficient for clinical practice. Although only data for helium beams was presented, the performance of the pencil beam algorithm for proton beams was comparable. Conclusions: The pencil beam algorithm developed for helium ions presents a suitable tool for dose calculations. Its calculation speed was evaluated to be similar to other published pencil beam algorithms. The flexible design allows easy customization of measured depth-dose distributions and use of varying beam profiles, thus making it a promising candidate for integration into future treatment planning systems. Current work in progress deals with RBE effects of helium ions to complete the model.

60 APPLIED LIFE SCIENCES↗

Dynamic topography and gravity anomalies for fluid layers whose viscosity varies exponentially with depth

Adopting the formalism of Parsons and Daly (1983), analytical integral equations (Green's function integrals) are derived which relate gravity anomalies and dynamic boundary topography with temperature as a function of wavenumber for a fluid layer whose viscosity varies exponentially with depth. In the earth, such a viscosity profile may be found in the asthenosphere, where the large thermal gradient leads to exponential decrease of viscosity with depth, the effects of a pressure increase being small in comparison. It is shown that, when viscosity varies rapidly, topography kernels for both the surface and bottom boundaries (and hence the gravity kernel) are strongly affected at all wavelengths.

Revenaugh, Justin↗

Observation and interpretation of the asymmetric Stokes Q, U, and V line profiles in sunspots

We present a first approach to systematic characterization and interpretation of observed asymmetries of Stokes profiles as a function of spatial position within sunspots. Spatial maps of the full Stokes profiles of Fe I 6302.5 A gathered in large sunspots using the HAO Stokes II instrument reveal asymmetries that vary systematically across large sunspots observed during 1980. We use the inversion technique by Landolfi to extract the velocity gradients along the line of sight (LOS) which give rise to these asymmetries. The gradients derived from full Stokes profiles are in agreement with previous characterizations of the Evershed flow derived from Stokes I profiles alone (i.e., a flow increasing with depth in the atmosphere). By coupling this semiempirical gradient of velocity with a magnetic field inclination varying along the LOS, the synthesized profiles are able to mimic basic observed features of the broad-band circular polarization present in our data and observed previously by others. This characterization has magnetic field lines which become progressively more horizontal with depth in the penumbra.

Sanchez Almeida, J.↗

TU-AB-BRA-12: Quality Assurance of An Integrated Magnetic Resonance Image Guided Adaptive Radiotherapy Machine Using Cherenkov Imaging

Purpose: To investigate the viability of using Cherenkov imaging as a fast and robust method for quality assurance tests in the presence of a magnetic field, where other instruments can be limited. Methods: Water tank measurements were acquired from a clinically utilized adaptive magnetic resonance image guided radiation therapy (MR-IGRT) machine with three multileaf-collimator equipped 60Co sources. Cherenkov imaging used an intensified charge coupled device (ICCD) camera placed 3.5m from the treatment isocenter, looking down the bore of the 0.35T MRI into a water tank. Images were post-processed to make quantitative comparison between Cherenkov light intensity with both film and treatment planning system predictions, in terms of percent depth dose curves as well as lateral beam profile measurements. A TG-119 commissioning test plan (C4: C-Shape) was imaged in real-time at 6.33 frames per second to investigate the temporal and spatial resolution of the Cherenkov imaging technique. Results: A .33mm/pixel Cherenkov image resolution was achieved across 1024×1024 pixels in this setup. Analysis of the Cherenkov image of a 10.5×10.5cm treatment beam in the water tank successfully measured the beam width at the depth of maximum dose within 1.2% of the film measurement at the same point. The percent depth dose curve for the same beam was on average within 2% of ionization chamber measurements for corresponding depths between 3–100mm. Cherenkov video of the TG-119 test plan provided qualitative agreement with the treatment planning system dose predictions, and a novel temporal verification of the treatment. Conclusions: Cherenkov imaging was successfully used to make QA measurements of percent depth dose curves and cross beam profiles of MRI-IGRT radiotherapy machines after only several seconds of beam-on time and data capture; both curves were extracted from the same data set. Video-rate imaging of a dynamic treatment plan provided new information regarding temporal dose deposition. This study has been funded by NIH grants R21EB17559 and R01CA109558, as well as Norris Cotton Cancer Center Pilot funding.

60 APPLIED LIFE SCIENCES↗

Comparison of film measurements and Monte Carlo simulations of dose delivered with very high-energy electron beams in a polystyrene phantom

Purpose: To measure radiation dose in a water-equivalent medium from very high-energy electron (VHEE) beams and make comparisons to Monte Carlo (MC) simulation results. Methods: Dose in a polystyrene phantom delivered by an experimental VHEE beam line was measured with Gafchromic films for three 50 MeV and two 70 MeV Gaussian beams of 4.0–6.9 mm FWHM and compared to corresponding MC-simulated dose distributions. MC dose in the polystyrene phantom was calculated with the EGSnrc/BEAMnrc and DOSXYZnrc codes based on the experimental setup. Additionally, the effect of 2% beam energy measurement uncertainty and possible non-zero beam angular spread on MC dose distributions was evaluated. Results: MC simulated percentage depth dose (PDD) curves agreed with measurements within 4% for all beam sizes at both 50 and 70 MeV VHEE beams. Central axis PDD at 8 cm depth ranged from 14% to 19% for the 5.4–6.9 mm 50 MeV beams and it ranged from 14% to 18% for the 4.0–4.5 mm 70 MeV beams. MC simulated relative beam profiles of regularly shaped Gaussian beams evaluated at depths of 0.64 to 7.46 cm agreed with measurements to within 5%. A 2% beam energy uncertainty and 0.286° beam angular spread corresponded to a maximum 3.0% and 3.8% difference in depth dose curves of the 50 and 70 MeV electron beams, respectively. Absolute dose differences between MC simulations and film measurements of regularly shaped Gaussian beams were between 10% and 42%. Conclusions: The authors demonstrate that relative dose distributions for VHEE beams of 50–70 MeV can be measured with Gafchromic films and modeled with Monte Carlo simulations to an accuracy of 5%. The reported absolute dose differences likely caused by imperfect beam steering and subsequent charge loss revealed the importance of accurate VHEE beam control and diagnostics.

07 ISOTOPE AND RADIATION SOURCES↗

AVCOAT Density Characterization for Orion Multi-Purpose Crew Vehicle

The Orion Multi-Purpose Crew Vehicle (MPCV) will transport four crew members to and from lunar-class orbital destinations. The first orbital Exploration Flight Test (EFT-1) is scheduled for December 2014 and will provide valuable data on several systems, including the heat shield. The heat shield material is AvcoatTM, a mid-density ablator. Specifically, the heat shield contains a fiberglass-phenolic honeycomb structure filled with an ablative epoxy novolac resin. Post-flight characterization of the EFT-1 thermal protection system will be conducted in order to study the material response and measure the char front of the material. Avcoat density profiling will be conducted to study three critical material zones: char, pyrolysis, and virgin states as a function of material depth. As part of a ground test campaign, Avcoat coupons are tested at the NASA Ames Research Center Arc Jet Complex. The test campaign is set forth to study material response based on environments, perform Avcoat material density characterization, and compare the char depths from the HEAT sensor and density profiling studies. These investigations will then be compared to flight data in order to improve upon TPS material response models.

AVCOAT↗

TH-E-BRE-03: A Novel Method to Account for Ion Chamber Volume Averaging Effect in a Commercial Treatment Planning System Through Convolution

Purpose: Fourier-based deconvolution approaches used to eliminate ion chamber volume averaging effect (VAE) suffer from measurement noise. This work aims to investigate a novel method to account for ion chamber VAE through convolution in a commercial treatment planning system (TPS). Methods: Beam profiles of various field sizes and depths of an Elekta Synergy were collected with a finite size ion chamber (CC13) to derive a clinically acceptable beam model for a commercial TPS (Pinnacle{sup 3}), following the vendor-recommended modeling process. The TPS-calculated profiles were then externally convolved with a Gaussian function representing the chamber (σ = chamber radius). The agreement between the convolved profiles and measured profiles was evaluated with a one dimensional Gamma analysis (1%/1mm) as an objective function for optimization. TPS beam model parameters for focal and extra-focal sources were optimized and loaded back into the TPS for new calculation. This process was repeated until the objective function converged using a Simplex optimization method. Planar dose of 30 IMRT beams were calculated with both the clinical and the re-optimized beam models and compared with MapCHEC™ measurements to evaluate the new beam model. Results: After re-optimization, the two orthogonal source sizes for the focal source reduced from 0.20/0.16 cm to 0.01/0.01 cm, which were the minimal allowed values in Pinnacle. No significant change in the parameters for the extra-focal source was observed. With the re-optimized beam model, average Gamma passing rate for the 30 IMRT beams increased from 92.1% to 99.5% with a 3%/3mm criterion and from 82.6% to 97.2% with a 2%/2mm criterion. Conclusion: We proposed a novel method to account for ion chamber VAE in a commercial TPS through convolution. The reoptimized beam model, with VAE accounted for through a reliable and easy-to-implement convolution and optimization approach, outperforms the original beam model in standard IMRT QA verification.

07 ISOTOPE AND RADIATION SOURCES↗

The transfer of resonance-line radiation in static astrophysical media

An analytic solution is derived for the mean intensity of resonance-line radiation within an absorbing medium of large scattering optical depth but low density. The line profile, the mean number of scatterings before absorption or escape, the mean path length traveled, and the fraction of the photons which escape the medium are derived. Approximate methods are also developed which permit the treatment of media of intermediate optical depth, where scattering takes place in the Doppler core. Astrophysical applications include the absorption of H Ly-alpha radiation by stellar dust, the pumping of H2 Lyman band lines by H Ly-alpha and the Bowen fluorescence.

Neufeld, David A.↗

Near-surface ice on Mercury and the Moon: A topographic thermal model

A thermal model that can be easily adapted to craters of arbitrary shape is developed and applied to high-latitude impact craters on Mercury and the Moon, Chao Meng Fu crater at -87.5 deg L on Mercury, an unnamed bowl-shaped crater at 86.7 deg L on Mercury, and Peary crater at 88.6 deg L on the Moon. For an assumed input topography and grid of surface elements, the model computes for each element the irradiation from direct insolation and reflected and emitted radiation from other elements, taking into account shadowing by walls of the crater, partial obscuration of the solar disk near the poles and the diurnal, orbital, and seasonal cycles. Temperatures are computed over the surface grid as functions of depth and time from the surface to a specified depth and over the pertinent astronomical cycles, including the effects of direct and indirect surface irradiation, infrared radiation, heat conduction, and interior heating. Vapor fluxes and ice recession times are computed as functions of ice depth over the surface grid. Temperatures profiles, vapor fluxes, and ice recession times were computed for flat surfaces not associated with craters near the poles of Mercury and the Moon. It was found that water ice could have existed throughout geologic time within the maximum radar detection depth of recent observation of Mercury (J. K. Harmon and M. A. Slade, 1992, Science 258, 640-643) poleward of approximately 87 - 88 deg L on Mercury and poleward of approximately 73 deg L on the Moon. For Chao Meng Fu crater it was found that approximately 40% of the crater floor is permanently shadowed from direct solar insolation, while the remainder of the crater floor is periodically illuminated by a partially obscured Sun. Temperatures at the upper levels of the south wall can slightly exceed 550 K. Surface temperatures in the permanently shadowed region of the crater floor are under approximately 130 K, which could have allowed water ice to exist throughout geologic time within the radar detection depth of recent observation of Mercury. For small bowl-shaped crater on Mercury, it was found that most of the crater is permanently shadowed from direct solar radiation, except for a narrow semicircular band bordering the north rim. However, temperatures in the permanently shadowed region periodically reach a maximum near approximately 315 K due to efficient heating of the small crater by thermal emission and reflection from the small sunlit region, which periodically reaches temperatures exceeding 630 K. Water ice could not have existed throughout geologic time anywhere in this crater within the radar detection depth. For Peary crater on the Moon, the entire crater floor is permanently shadowed from direct solar insolation with maximum temperature under 120 K. The upper level of the north wall periodically reaches a maximum temperature near 310 K. The low temperatures on the crater floor would have allowed water ice to exist near the surface throughout geologic time, provided that the Moon's obliquity was always as low as it is at present.

Salvail, James R.↗

SECONDARY ECLIPSE PHOTOMETRY OF THE EXOPLANET WASP-5b WITH WARM SPITZER

We present secondary eclipse photometry of the extrasolar planet WASP-5b taken in the 3.6 and 4.5 {mu}m bands with the Spitzer Space Telescope's Infrared Array Camera as part of the extended warm mission. By estimating the depth of the secondary eclipse in these two bands we can place constraints on the planet's atmospheric pressure-temperature profile and chemistry. We measure secondary eclipse depths of 0.197% {+-} 0.028% and 0.237% {+-} 0.024% in the 3.6 {mu}m and 4.5 {mu}m bands, respectively. For the case of a solar-composition atmosphere and chemistry in local thermal equilibrium, our observations are best matched by models showing a hot dayside and, depending on our choice of model, a weak thermal inversion or no inversion at all. We measure a mean offset from the predicted center of eclipse of 3.7 {+-} 1.8 minutes, corresponding to ecos {omega} = 0.0025 {+-} 0.0012 and consistent with a circular orbit. We conclude that the planet's orbit is unlikely to have been perturbed by interactions with another body in the system as claimed by Fukui et al.

79 ASTRONOMY AND ASTROPHYSICS↗

Effects of insertion loss, laser profile and inhomogeneity of dots distribution on properties of all-optical modulator based on GaN/AlN quantum dots

This paper reports the effects of insertion loss, laser profile and inhomogeneity of dots distribution on properties of an all-optical modulator based on spherical quantum dot. The aim of this paper is to give a quantitative description for the variation of main properties of an all-optical quantum dot modulator such as, absorption, transmission and modulation depth regard to insertion loss, laser profile and inhomogeneity of dots. To realize these points, first, we extract the field distribution in optical fiber and channel waveguide (modulator) which are defined by their structure characteristics and boundary conditions. Using the electric field equations, input coupling efficiency and insertion loss and also role of laser profile are observable. Finally we investigate the effect of size distribution and inhomogeneity of quantum dots on the modulator performance. In this structure we used electromagnetically induced transparency (EIT) in GaN/AlN structure, associated with inter-sublevel transitions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Meteorology and Snow Data Set From Adjacent Forested and Meadow Sites at Crested Butte, CO, USA

We present meteorology and snow observation data collected at sites in the southwestern Colorado Rocky Mountains (USA) over three consecutive water years with different amounts of snow water equivalent (SWE) accumulation: A year with above average SWE (2019), a year with average SWE (2020), and a year with below average SWE (2021). This data set is distinguished by its emphasis on paired open-forest sites in a continental snow climate. Approximately once a month during February–May, we collected data from 15 to 20 snow pits and took 8 to 19 snow depth transects. Our sampling sites were in open and adjacent forested areas at 3,100 m and in a lower elevation aspen (3,035 m) and higher elevation conifer stand (3,395 m). In total, we recorded 270 individual snow pit density and temperature profiles and over 4,000 snow depth measurements. These data are complimented by continuous meteorological measurements from two weather stations: One in the open and one in the adjacent forest. Meteorology data—including incoming shortwave and longwave radiation, outgoing shortwave radiation, relative humidity, wind speed, snow depth, and air and infrared surface temperature—were quality controlled and the forcing data were gap-filled. These data are available to download from Bonner, Smyth, et al. at three levels of processing, including a level with downscaled, adjusted precipitation based on data assimilation using observed snow depth and a process-based snow model. We demonstrate the utility of these data with a modeling experiment that explores open-forest differences and identifies opportunities for improvements in model representation.

54 ENVIRONMENTAL SCIENCES↗

Water foraging with dynamic roots in E3SM; The role of roots in terrestrial ecosystem memory on intermediate timescales (Final Technical Report)

Terrestrial ecosystems can show sustained responses to stress events that may last for years after the initial perturbation. This phenomenon is referred to as legacy or memory and it emerges from a set of ecosystem processes that are poorly captured by Earth System and Land Surface Models. Consequently, these models struggle to predict the impact that extreme climate events have on surface energy, carbon and hydrological exchange once a stressor such as drought has relaxed or in response to repeated exposure to stress. In this project, we set out to test how the addition of dynamic root profiles in land surface models impact the capacity for Earth System Models, such as the Department of Energy’s E3SM, to capture realistic legacy effects. Observations have shown that vegetation shifts their root profiles during stress events to forage for water and these altered root profiles may take years to relax back to the initial state. We hypothesized that the alteration of the belowground root structures may be a source of terrestrial ecosystem legacy that is missing from models. To test this idea we undertook three core activities. (1) We developed a global-scale analysis of the impact of dynamic roots on ecosystem legacy building from a recently developed dynamic root module. (2) We developed new root dynamics in the DOE’s Energy Land Model (ELM) that allowed not only root profiles to shift their profile but also simultaneously alter carbon allocation to fine root pools. We then tested the impact of these new dynamics with intensive sensitivity analysis at four long-term AmeriFlux sites. (3) We undertook detailed isotopic analysis of tree rings from these AmeriFlux sites to assess ecophysiological and ecohydrological legacy to stress events that can be used to benchmark the sensitivity experiments with ELM. From these core activities, we report the following key findings. Firstly, on a global scale, the addition of dynamic roots led to chronically water-stressed ecosystems recovering faster to climate stress while wetter ecosystem showed enhanced legacy. This is because across ecosystems, stress events were almost universally associated with water shortages that led to the development of deeper root profiles. These deeper root profiles proved beneficial for recovery from drought stress. While the root dynamics did not universally improve the modeled representation of legacy it showed complex transient dynamics that emerge from the addition of dynamic roots. Secondly, the sensitivity analysis illustrated long term shifts in rooting depths away from the prescribed default profile suggesting that initializing of root profiles could benefit from spin-up simulations that converge on locally optimized root profiles. In addition, by enabling dynamic allocation some of the sites predicted unrealistically low allocation to roots (and high allocation to leaves). While these changes did not dramatically alter modeled gross primary productivity, they illustrated that without more sophisticated root processes in models, there is little penalty to dramatically disinvest in roots. Thirdly, the isotopic analysis of tree rings showed highly distinct legacy responses across species and sites. For example, T. canadensis showed reduced transpiration the year after stress events illustrated by sustained elevated $\delta^{18}$O. In contrast, A saccharum displayed elevated $\delta^{13}$C associated with reduced stomatal conductance in response to the previous years’ stress event. These geochemical signatures of legacy were present despite tree growth returning to normal the year after the stress. The results show the importance of species-level dynamics in legacy that are absent in modeling that assumes common traits within plant functional types. In summary, the work here established new avenues to explore root dynamics in models while illustrating how additional root processes are needed before dynamic carbon allocation can be implemented. Lastly, this project provided mentorship to a postdoctoral fellow, training for an early career scientist and multiple undergraduate students recruited from a minority serving institution.

54 ENVIRONMENTAL SCIENCES↗

Aerobic respiration controls on shale weathering, Geochimica et Cosmochimica Acta, 2023: Dataset

This data package was generated in order to support the development of a deep-time weathering model and to assess the coupling between shale weathering and aerobic respiration in the paper “Aerobic respiration controls on shale weathering” by Stolze et al., Geochimica et Cosmochimica Acta (2023). The package contains two csv files providing the average CO2(g) concentration profiles [ppm] and mineral concentration profiles [wt%], respectively. The CO2(g) concentration profiles were measured in the vicinity of the monitoring well PLM2 between January 2018 and April 2019. The gas samples were collected in the unsaturated zone to a depth of 1.52 m. The mineral concentration profiles were determined by X-Ray diffraction (XRD). The XRD measurements were performed on sub-core samples collected in the monitoring well PLM3 down to a depth of 7.01 m. The dataset additionally includes a file-level metadata (flmd.csv) file that lists each file contained in the dataset with associated metadata; and a data dictionary (dd.csv) file that contains column/row headers used throughout the files along with a definition, units, and data type.Update on 2024-05-28: Revised versions of the CSV data files (CO2_data_GCA_Stolze_et_al_2023.csv and XRD_data_GCA_Stolze_et_al_2023.csv) were made to apply ESS-DIVE's CSV reporting format guidelines. Updated versions of the File Level Metadata (v2_20240528_flmd.csv) and Data Dictionary (v2_20240528_dd.csv) files were updated to reflect the changes made to the CSV files.

54 ENVIRONMENTAL SCIENCES↗

Standardization of a Volumetric Displacement Measurement for Two-Body Abrasion Scratch Test Data Analysis

A limitation has been identified in the existing test standards used for making controlled, two-body abrasion scratch measurements based solely on the width of the resultant score on the surface of the material. A new, more robust method is proposed for analyzing a surface scratch that takes into account the full three-dimensional profile of the displaced material. To accomplish this, a set of four volume- displacement metrics was systematically defined by normalizing the overall surface profile to denote statistically the area of relevance, termed the Zone of Interaction. From this baseline, depth of the trough and height of the plowed material are factored into the overall deformation assessment. Proof-of-concept data were collected and analyzed to demonstrate the performance of this proposed methodology. This technique takes advantage of advanced imaging capabilities that allow resolution of the scratched surface to be quantified in greater detail than was previously achievable. When reviewing existing data analysis techniques for conducting two-body abrasive scratch tests, it was found that the ASTM International Standard G 171 specified a generic metric based only on visually determined scratch width as a way to compare abraded materials. A limitation to this method was identified in that the scratch width is based on optical surface measurements, manually defined by approximating the boundaries, but does not consider the three-dimensional volume of material that was displaced. With large, potentially irregular deformations occurring on softer materials, it becomes unclear where to systematically determine the scratch width. Specifically, surface scratches on different samples may look the same from a top view, resulting in an identical scratch width measurement, but may vary in actual penetration depth and/or plowing deformation. Therefore, two different scratch profiles would be measured as having identical abrasion properties, although they differ significantly.

Street, K. W. Jr.↗