Search NASA⌕ Search

SEARCH · Search NASA

Results for “depth profiling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

SU-E-T-485: Investigation of a Synthetic Diamond Detector for Tomotherapy Dosimetry

Purpose: Tomotherapy treatments are characterized by rotational deliveries of flattening-filter free fields resulting in high-gradient dose distributions. Small volume, rotationally independent detectors are needed for accurate dosimetry. PTWs microDiamond detector, with its small sensitive volume (0.004mm{sup 3}), could potentially be an ideal detector for Tomotherapy. The microDiamond detector was tested against a small volume Exradin A1SL ion chamber for Tomotherapy open-field and IMRT commissioning measurements. Methods: Custom detector holders were fabricated to allow A1SL and microDiamond measurements in the Tomotherapy Cheese phantom and a square solid water phantom. The microDiamond rotational dependence within the Tomotherapy phantom was tested by incrementally rotating the detector in between static-gantry angle Tomotherapy irradiations. Longitudinal Tomotherapy profiles, for all field sizes, were measured with the microDiamond and A1SL detectors at 1.5cm depth in the square phantom, and compared to film. Detector axes were aligned parallel to table motion. Per TG-119 recommendations, both detectors were calibrated to known doses in phantoms and used to measure high-dose points in TG-119 H and N and Prostate plans. The measurements were compared to the treatment planning system and subsequently compared to published TG-119 confidence limits. Results: The microDiamond angular dependence was less than 0.5%. The average difference between the detectors and film-measured longitudinal profile 80–20% penumbras were 0.03+/-0.04mm and 1.36+/-0.22mm for the microDiamond and A1SL, respectively. The average difference between the detector and filmmeasured field sizes were 0.07+/-0.01mm and 0.09+/-0.02mm for the microDiamond and A1SL, respectively. The measured confidence limits were 0.023 and 0.015 for microDiamond and A1SL, respectively. TG-119 reported a confidence limit of 0.034. Conclusion: The microDiamond measured open-field longitudinal Tomotherapy profiles more closely resembled film measurements, compared with the A1Sl chamber. Furthermore, the microDiamond was shown to have low angular dependence and both detectors were able to accurately measure the highdose points in TG-119 H and N and prostate plans. Our institution has research grants with PTW.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Extracting band edge profiles at semiconductor heterostructures from hard-x-ray core-level photoelectron spectra

Hard-x-ray photoelectron spectroscopy (HAXPES) is a valuable source of information on band-edge profiles deep inside semiconductor thin films and heterojunctions. However, extracting this information requires robust and physically meaningful decomposition of spectra into contributions from individual atomic planes. We present an approach that utilizes the physical requirements of a monotonic dependence of the built-in electrostatic potential on depth and continuity of the potential function and its derivatives. These constraints enable efficient extraction of band-edge profiles and allow one to capture details of the electronic structure, including determination of the signs and magnitudes of the band bending as well as the valence band offsets. The utility of this approach to generate quantitative insight into the electronic structure of complex materials is illustrated for epitaxial SrTiO 3 on intrinsic Si(001).

97 MATHEMATICS AND COMPUTING↗

Observations Pertaining to Precipitation within the Northeast Pacific Stratocumulus-to-Cumulus Transition

Three genuine stratocumulus-to-cumulus transitions sampled during the Cloud System Evolution over the Trades (CSET) campaign are documented. The focus is on Lagrangian evolution of in situ precipitation, thought to exceed radar/lidar retrieved values because of Mie scattering. Two of the three initial stratocumulus cases are pristine [cloud droplet number concentrations ($N_d$) of ~22 cm –3 ] but occupied boundary layers of different depths, while the third is polluted ($N_d$ ~ 225 cm –3 ). Hourly satellite-derived cloud fraction along Lagrangian trajectories indicate that more quickly deepening boundary layers tend to transition faster, into more intense but more occasional precipitation. These transitions begin either in the morning or late afternoon, suggesting that preceding night processes can precondition or delay the inevitable transition. The precipitation shifts toward larger drop sizes throughout the transition as the boundary layers deepen, with aerosol concentrations only diminishing in two of the three cases. Ultraclean ($N_d$ < 1 cm –3 ) cumulus clouds evolved from pristine stratocumulus cloud with unusually high precipitation rates occupying a shallow, well-mixed boundary layer. Results from a simple one-dimensional evaporation model and from radar/lidar retrievals suggest subcloud evaporation likely increases throughout the transition. This, coupled with larger drop sizes capable of lowering the latent cooling profile, facilitates the transition to more surface-driven convection. The coassociation between boundary layer depth and precipitation does not provide definitive conclusions on the isolated effect of precipitation on the pace of the transition. Differences between the initial conditions of the three examples provide opportunities for further modeling studies.

54 ENVIRONMENTAL SCIENCES↗

Wall scanning probe for high-field side plasma measurements on Alcator C-Mod

A new, high-field side scanning probe has been added to Alcator C-Mod's complement of edge diagnostics. The wall scanning probe is designed to provide all the benefits of a linear plunge, multielectrode scanning probe while working from the confined space of the inner tokamak wall. The drive mechanism is an embedded coil which produces a torque with the ambient toroidal magnetic field when energized, thus allowing the probe to plunge to different preprogramed depths at different times during a plasma discharge. The probe tip is designed for easy replacement and is presently configured to operate as a modified, high heat-flux ''Gundestrup-type'' probe with four tungsten electrodes. The probe has demonstrated the ability to obtain cross-field profiles for electron temperature, density, floating potential, and plasma flow information (parallel and perpendicular to B) up to a depth of a few millimiters inside the last-closed flux surface in standard C-Mod discharges. The tungsten-tipped probe has proved very robust and shows little or no damage though it routinely handles surface heat fluxes on the order of 100 MW/m{sup 2} at peak insertion.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fort Bliss Geothermal Area Data: Temperature profile, logs, schematic model and cross section

This dataset contains a variety of data about the Fort Bliss geothermal area, part of the southern portion of the Tularosa Basin, New Mexico. The dataset contains schematic models for the McGregor Geothermal System, a shallow temperature survey of the Fort Bliss geothermal area. The dataset also contains Century OH logs, a full temperature profile, and complete logs from well RMI 56-5, including resistivity and porosity data, drill logs with drill rate, depth, lithology, mineralogy, fractures, temperature, pit total, gases, and descriptions among other measurements as well as CDL, CNL, DIL, GR Caliper and Temperature files. A shallow (2 meter depth) temperature survey of the Fort Bliss geothermal area with 63 data points is also included. Two cross sections through the Fort Bliss area, also included, show well position and depth. The surface map included shows faults and well spatial distribution. Inferred and observed fault distributions from gravity surveys around the Fort Bliss geothermal area.

15 GEOTHERMAL ENERGY↗

X-ray spectroscopy of buried layer foils irradiated at laser intensities in excess of 10{sup 20} W/cm{sup 2}

Observations of a rapid decrease in thermal temperature as a function of depth of solid targets irradiated with a short pulse, ultrahigh-intensity laser are reported. This phenomenon is investigated using the Titan short pulse laser with intensities greater than 10{sup 20} W/cm{sup 2} interacting with buried layer targets. The longitudinal temperature profile is determined by measuring K-shell spectra from a 0.4 {mu}m copper tracer layer placed at various depths (i.e., 0-1.5 {mu}m) within the 2.4 {mu}m thick target. It is observed that the line ratios (He-like K-shell lines) as a function of temperature require a consideration of at least three parameters to analyze the K-shell spectra: hot electron population, time-dependent plasma conditions, and opacity. Here, the study of the effect of these three parameters on measured spectra in the short pulse high intensity laser-matter interactions using the atomic model FLYCHK[H.-K. Chung et al., High Energy Density Phys. 1, 3 (2005)] is presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

TH-CD-201-09: High Spatial Resolution Absorbed Dose to Water Measurements Using Optical Calorimetry in Megavoltage External Beam Therapy

Purpose: To develop and implement a high spatial resolution calorimeter methodology to measure absorbed dose to water (ADW) using phase shifts (PSs) of light passing through a water phantom and to compare measurements with theoretical calculations. Methods: Radiation-induced temperature changes were measured using the PSs of a He-Ne laser beam passing through a (10×10×10) cm{sup 3} water phantom. PSs were measured using a Michelson interferometer and recording the time-dependent fringe patterns on a CCD camera. The phantom was positioned at the center of the radiation field. A Varian 21EX was used to deliver 500 MU from a 9 MeV beam using a (6×6) cm{sup 2} cone. A 127cm SSD was used and the PSs were measured at depths ranging from of 1.90cm to 2.10cm in steps of 0.05cm by taking profiles at the corresponding rows across the image. PSs were computed by taking the difference between pre- and post-irradiation image frames and then measuring the amplitude of the resulting image profiles. An amplitude-to-PS calibration curve was generated using a piezoelectric transducer to mechanically induce PSs between 0.05 and 1.50 radians in steps of 0.05 radians. The temperature dependence of the refractive index of water at 632.8nm was used to convert PSs to ADW. Measured results were compared with ADW values calculated using the linac output calibration and commissioning data. Results: Milli-radian resolution in PS measurement was achieved using the described methodology. Measured radiation-induced PSs ranged from 0.10 ± 0.01 to 0.12 ± 0.01 radians at the investigated depths. After converting PSs to ADW, measured and calculated ADW values agreed within the measurement uncertainty. Conclusion: This work shows that interferometer-based calorimetry measurements are capable of achieving sub-millimeter resolution measuring 2D temperature/dose distributions, which are particularly useful for characterizing beams from modalities such as SRS, proton therapy, or microbeams.

60 APPLIED LIFE SCIENCES↗

Validation of Wichner Predictive Model for Chronic Oxidation by Moisture of Nuclear Graphite

This document reports the results of multi-year extensive research on chronic oxidation of nuclear graphite by traces of moisture that might be present in the helium coolant of high-temperature gas-cooled reactors (HTGRs). The research focuses on four grades of nuclear graphite that are considered potential candidates for component fabrication in advanced nuclear reactors. The four grades are (1) PCEA (medium-fine grain, extruded, manufactured by GrafTech Inc., USA); (2) NBG-17 (medium-fine grain, vibrationally molded, manufactured by SGL Carbon, Germany/France); (3) IG-110 (microfine grain, isostatically molded, manufactured by Toyo Tanso, Japan); and (4) 2114 (microfine grain, isostatically pressed, manufactured by Mersen, USA). The experimental part of this research comprised three objectives that were consistently pursued for each graphite material: (1) accelerated oxidation tests in well-controlled conditions (temperature, gas composition) and analysis of chemical kinetic models and of their parameters for each graphite grade; (2) measurements of water vapor transport rates from H 2 O/He mixtures through thin graphite slabs for estimation of the water effective diffusivity specific to each material; (3) controlled oxidation of graphite specimens in H 2 O/He mixtures and characterization of the effects of oxidation temperatures on the density profiles of oxidized layers. These three groups of experimental results were interpreted using the model developed by Wichner et al. for predicting the penetration depth of oxidants (moisture or oxygen) as a function of oxidation conditions. Basically, starting from the kinetic and transport properties of each graphite grade, the ultimate goal was predicting the stable density profile in the oxidized layer and its dependence on the oxidation temperature. The profiles obtained this way were then compared against direct observations of oxidized layers in specimens obtained in well-controlled oxidation conditions. The general agreement between predictions and observations validated the general applicability of the Wichner model. The results obtained in this project were presented at annual Department of Energy–Advanced Reactor Technologies program reviews and at specialist meetings and conferences and were published in Oak Ridge National Laboratory (ORNL) reports and in professional journals. The results published in 2018 had an immediate impact in 2019, when a group from three US universities used ORNL kinetic data as input information in a complex simulation of chronic oxidation by moisture using the same graphite grades during long-time operation in a modular high-temperature gas-cooled reactor. Their conclusion, in line with the conclusions obtained at the end of this project, was that chronic graphite oxidation by moisture during normal operation conditions of an HTGR will be limited to a thin surface layer of graphite blocks at the reactor bottom, where the highest temperatures are. That will not affect the integrity of graphite components and reactor safety, provided the impurity concentration in the helium coolant is rigorously controlled and maintained at the design specifications.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Vertical Tracer Concentration Profiles Measured During the Joint Urban 2003 Dispersion Study

An atmospheric tracer dispersion study known as Joint Urban 2003 was conducted in Oklahoma City, Oklahoma during the summer of 2003. As part of this field program, vertical concentration profiles were measured at approximately 1 km from downtown tracer gas release locations. These profiles indicated that the urban landscape was very effective in mixing the plume vertically. The height of the plume centerline (as determined by the maximum concentration over the depth of the measurements) for any specific 30 min period varied over the 65 m measurement range. Most of the variations in tracer concentration observed in the profile time series were related to changes in wind direction as opposed to changes in turbulence. As a simple analysis tool for emergency response, maximum normalized concentration curves were developed with 5-minute averaged measurements. These curves give the maximum concentration (normalized by the release rate) that would be observed as a function of downwind distance in an urban area. The 5-min data resulted in greater concentrations than predicted with a simple Gaussian plume model. However, the curve compared well with results from a computational fluid dynamics simulation. This dispersion dataset is a valuable asset not only for refining air quality models, but also for developing new tools for emergency response personnel in the event of a toxic release.

54 ENVIRONMENTAL SCIENCES↗

SU-E-T-800: Verification of Acurose XB Dose Calculation Algorithm at Air Cavity-Tissue Interface Using Film Measurement for Small Fields of 6-MV Flattening Filter-Free Beams

Purpose: To verify the dose accuracy of Acuros XB (AXB) dose calculation algorithm at air-tissue interface using inhomogeneous phantom for 6-MV flattening filter-free (FFF) beams. Methods: An inhomogeneous phantom included air cavity was manufactured for verifying dose accuracy at the air-tissue interface. The phantom was composed with 1 and 3 cm thickness of air cavity. To evaluate the central axis doses (CAD) and dose profiles of the interface, the dose calculations were performed for 3 × 3 and 4 × 4 cm{sup 2} fields of 6 MV FFF beams with AAA and AXB in Eclipse treatment plainning system. Measurements in this region were performed with Gafchromic film. The root mean square errors (RMSE) were analyzed with calculated and measured dose profile. Dose profiles were divided into inner-dose profile (>80%) and penumbra (20% to 80%) region for evaluating RMSE. To quantify the distribution difference, gamma evaluation was used and determined the agreement with 3%/3mm criteria. Results: The percentage differences (%Diffs) between measured and calculated CAD in the interface, AXB shows more agreement than AAA. The %Diffs were increased with increasing the thickness of air cavity size and it is similar for both algorithms. In RMSEs of inner-profile, AXB was more accurate than AAA. The difference was up to 6 times due to overestimation by AAA. RMSEs of penumbra appeared to high difference for increasing the measurement depth. Gamma agreement also presented that the passing rates decreased in penumbra. Conclusion: This study demonstrated that the dose calculation with AXB shows more accurate than with AAA for the air-tissue interface. The 2D dose distributions with AXB for both inner-profile and penumbra showed better agreement than with AAA relative to variation of the measurement depths and air cavity sizes.

60 APPLIED LIFE SCIENCES↗

Experimental evaluation of a spatial resampling technique to improve the accuracy of pencil-beam dose calculation in proton therapy

Purpose: In proton therapy, pencil-beam algorithms (PBAs) are the most widely used dose calculation methods. However, the PB calculations that employ one-dimensional density scaling neglect the effects of lateral density heterogeneity on the dose distributions, whereas some particles included in such pencil beams could overextend beyond the interface of the density heterogeneity. We have simplified a pencil-beam redefinition algorithm (PBRA), which was proposed for electron therapy, by a spatial resampling technique toward an application for proton therapy. The purpose of this study is to evaluate the calculation results of the spatial resampling technique in terms of lateral density heterogeneity by comparison with the dose distributions that were measured in heterogeneous slab phantoms. Methods: The pencil beams are characterized for multiple residual-range (i.e., proton energy) bins. To simplify the PBRA, the given pencil beams are resampled on one or two transport planes, in which smaller sub-beams that are parallel to each other are generated. We addressed the problem of lateral density heterogeneity comparing the calculation results to the dose distributions measured at different depths in heterogeneous slab phantoms using a two-dimensional detector. Two heterogeneity slab phantoms, namely, phantoms A and B, were designed for the measurements and calculations. In phantom A, the heterogeneity slab was placed close to the surface. On the other hand, in phantom B, it was placed close to the Bragg peak in the mono-energetic proton beam. Results: In measurements, lateral dose profiles showed a dose reduction and increment in the vicinity of x= 0 mm in both phantoms at depths z= 142 and 161 mm due to lateral particle disequilibrium. In phantom B, these dose reduction/increment effects were higher/lower, respectively, than those in phantom A. This is because a longer distance from the surface to the heterogeneous slab increases the strength of proton scattering. Sub-beams, which were generated from the resampling plane, formed a detouring/overextending path that was different from that of elemental pencil beams. Therefore, when the spatial resampling was implemented at the surface and immediately upstream of the lateral heterogeneity, the calculation could predict these dose reduction/increment effects. Without the resampling procedure, these dose reduction/increment effects could not be predicted in both phantoms owing to the blurring of the pencil beam. We found that the PBA with the spatial resampling technique predicted the dose reduction/increment at the dose profiles in both phantoms when the sampling plane was defined immediately upstream of the heterogeneous slab. Conclusions: We have demonstrated the implementation of a spatial resampling technique for pencil-beam calculation to address the problem of lateral density heterogeneity. While further validation is required for clinical use, this study suggests that the spatial resampling technique can make a significant contribution to proton therapy.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dosimetry of cone-defined stereotactic radiosurgery fields with a commercial synthetic diamond detector

Purpose: Small field x-ray beam dosimetry is difficult due to lack of lateral electronic equilibrium, source occlusion, high dose gradients, and detector volume averaging. Currently, there is no single definitive detector recommended for small field dosimetry. The objective of this work was to evaluate the performance of a new commercial synthetic diamond detector, namely, the PTW 60019 microDiamond, for the dosimetry of small x-ray fields as used in stereotactic radiosurgery (SRS). Methods: Small field sizes were defined by BrainLAB circular cones (4–30 mm diameter) on a Novalis Trilogy linear accelerator and using the 6 MV SRS x-ray beam mode for all measurements. Percentage depth doses (PDDs) were measured and compared to an IBA SFD and a PTW 60012 E diode. Cross profiles were measured and compared to an IBA SFD diode. Field factors, Ω{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}}, were calculated by Monte Carlo methods using BEAMnrc and correction factors, k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}}, were derived for the PTW 60019 microDiamond detector. Results: For the small fields of 4–30 mm diameter, there were dose differences in the PDDs of up to 1.5% when compared to an IBA SFD and PTW 60012 E diode detector. For the cross profile measurements the penumbra values varied, depending upon the orientation of the detector. The field factors, Ω{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}}, were calculated for these field diameters at a depth of 1.4 cm in water and they were within 2.7% of published values for a similar linear accelerator. The corrections factors, k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}}, were derived for the PTW 60019 microDiamond detector. Conclusions: The authors conclude that the new PTW 60019 microDiamond detector is generally suitable for relative dosimetry in small 6 MV SRS beams for a Novalis Trilogy linear equipped with circular cones.

07 ISOTOPE AND RADIATION SOURCES↗

Permanent-magnet energy spectrometer for electron beams from radiotherapy accelerators

Purpose: The purpose of this work was to adapt a lightweight, permanent magnet electron energy spectrometer for the measurement of energy spectra of therapeutic electron beams. Methods: An irradiation geometry and measurement technique were developed for an approximately 0.54-T, permanent dipole magnet spectrometer to produce suitable latent images on computed radiography (CR) phosphor strips. Dual-pinhole electron collimators created a 0.318-cm diameter, approximately parallel beam incident on the spectrometer and an appropriate dose rate at the image plane (CR strip location). X-ray background in the latent image, reduced by a 7.62-cm thick lead block between the pinhole collimators, was removed using a fitting technique. Theoretical energy-dependent detector response functions (DRFs) were used in an iterative technique to transform CR strip net mean dose profiles into energy spectra on central axis at the entrance to the spectrometer. These spectra were transformed to spectra at 95-cm source to collimator distance (SCD) by correcting for the energy dependence of electron scatter. The spectrometer was calibrated by comparing peak mean positions in the net mean dose profiles, initially to peak mean energies determined from the practical range of central-axis percent depth-dose (%DD) curves, and then to peak mean energies that accounted for how the collimation modified the energy spectra (recalibration). The utility of the spectrometer was demonstrated by measuring the energy spectra for the seven electron beams (7–20 MeV) of an Elekta Infinity radiotherapy accelerator. Results: Plots of DRF illustrated their dependence on energy and position in the imaging plane. Approximately 15 iterations solved for the energy spectra at the spectrometer entrance from the measured net mean dose profiles. Transforming those spectra into ones at 95-cm SCD increased the low energy tail of the spectra, while correspondingly decreasing the peaks and shifting them to slightly lower energies. Energy calibration plots of peak mean energy versus peak mean position of the net mean dose profiles for each of the seven electron beams followed the shape predicted by the Lorentz force law for a uniform z-component of the magnetic field, validating its being modeled as uniform (0.542 ± 0.027 T). Measured Elekta energy spectra and their peak mean energies correlated with the 0.5-cm (7–13 MeV) and the 1.0-cm (13–20 MeV) R{sub 90} spacings of the %DD curves. The full-width-half-maximum of the energy spectra decreased with decreasing peak mean energy with the exception of the 9-MeV beam, which was anomalously wide. Similarly, R{sub 80–20} decreased linearly with peak mean energy with the exception of the 9 MeV beam. Both were attributed to suboptimal tuning of the high power phase shifter for the recycled radiofrequency power reentering the traveling wave accelerator. Conclusions: The apparatus and analysis techniques of the authors demonstrated that an inexpensive, lightweight, permanent magnet electron energy spectrometer can be used for measuring the electron energy distributions of therapeutic electron beams (6–20 MeV). The primary goal of future work is to develop a real-time spectrometer by incorporating a real-time imager, which has potential applications such as beam matching, ongoing beam tune maintenance, and measuring spectra for input into Monte Carlo beam calculations.

60 APPLIED LIFE SCIENCES↗

Photothermal Investigation of Micro-Uniformity Problems Caused by Different Scan Systems

To study beam scanning and beam profiling effects low energy implants of Boron (25 keV) and high energy implants of Helium (5.4 MeV) were carried out by use of different scanning systems including mechanical, electrostatic and hybrid scanning. The sensitivity of photothermal measurement by use of the excess carrier wave in the depth up to 50 {mu}m is proved for buried damage detection and compared with the effect in shallow damage profiles. The micro-mapping capability of the photothermal techniques allows the detection of dose variations in a sub-mm-scale without Moire effects from mapping steps. Conclusion for advanced dose monitoring by multi-frequency photothermal methods will be derived.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The temperature and size distribution of large water clusters from a non-equilibrium model

A hybrid Lagrangian-Eulerian approach is used to examine the properties of water clusters formed in neon-water vapor mixtures expanding through microscale conical nozzles. Experimental size distributions were reliably determined by the sodium doping technique in a molecular beam machine. The comparison of computed size distributions and experimental data shows satisfactory agreement, especially for (H{sub 2}O){sub n} clusters with n larger than 50. Thus validated simulations provide size selected cluster temperature profiles in and outside the nozzle. This information is used for an in-depth analysis of the crystallization and water cluster aggregation dynamics of recently reported supersonic jet expansion experiments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ultrafast two-photon fluorescence imaging of cerebral blood circulation in the mouse brain in vivo

Characterizing blood flow dynamics in vivo is critical to understanding the function of the vascular network under physiological and pathological conditions. Existing methods for hemodynamic imaging have insufficient spatial and temporal resolution to monitor blood flow at the cellular level in large blood vessels. By using an ultrafast line-scanning module based on free-space angular chirped enhanced delay, we achieved two-photon fluorescence imaging of cortical blood flow at 1,000 two-dimensional (2D) frames and 1,000,000 one-dimensional line scans per second in the awake mouse. This orders-of-magnitude increase in temporal resolution allowed us to measure cerebral blood flow at up to 49 mm/s and observe pulsatile blood flow at harmonics of heart rate. Directly visualizing red blood cell (RBC) flow through vessels down to >800 µm in depth, we characterized cortical layer–dependent flow velocity distributions of capillaries, obtained radial velocity profiles and kilohertz 2D velocity mapping of multifile blood flow, and performed RBC flux measurements from penetrating blood vessels.

59 BASIC BIOLOGICAL SCIENCES↗

THE TEMPERATURE OF HOT GAS IN GALAXIES AND CLUSTERS: BARYONS DANCING TO THE TUNE OF DARK MATTER

The temperature profile of hot gas in galaxies and galaxy clusters is largely determined by the depth of the total gravitational potential and thereby by the dark matter (DM) distribution. We use high-resolution hydrodynamical simulations of galaxy formation to derive a surprisingly simple relation between the gas temperature and DM properties. We show that this relation holds not just for galaxy clusters but also for equilibrated and relaxed galaxies at radii beyond the central stellar-dominated region of typically a few kpc. It is then clarified how a measurement of the temperature and density of the hot gas component can lead to an indirect measurement of the DM velocity anisotropy in galaxies. We also study the temperature relation for galaxy clusters in the presence of self-regulated, recurrent active galactic nuclei (AGNs), and demonstrate that this temperature relation even holds outside the inner region of {approx}30 kpc in clusters with an active AGN.

79 ASTRONOMY AND ASTROPHYSICS↗

Near total reflection x-ray photoelectron spectroscopy: quantifying chemistry at solid/liquid and solid/solid interfaces

Near total reflection regime has been widely used in x-ray science, specifically in grazing incidence small angle x-ray scattering and in hard x-ray photoelectron spectroscopy (XPS). In this work, we introduce some practical aspects of using near total reflection (NTR) in ambient pressure XPS and apply this technique to study chemical concentration gradients in a substrate/photoresist system. Experimental data are accompanied by x-ray optical and photoemission simulations to quantitatively probe the photoresist and the interface with the depth accuracy of ~1 nm. Together, our calculations and experiments confirm that NTR XPS is a suitable method to extract information from buried interfaces with highest depth-resolution, which can help address open research questions regarding our understanding of concentration profiles, electrical gradients, and charge transfer phenomena at such interfaces. Furthermore, the presented methodology is especially attractive for solid/liquid interface studies, since it provides all the strengths of a Bragg-reflection standing-wave spectroscopy without the need of an artificial multilayer mirror serving as a standing wave generator, thus dramatically simplifying the sample synthesis.

solid/solid interface↗