Search NASA⌕ Search

SEARCH · Search NASA

Results for “device testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

Magnetic Device Design and Evaluation Capabilities at JPL

This viewgraph presentation describes the magnetic device design and evaluation capabilities at the Center for Space Microelectronics Technology at the Jet Propulsion Laboratory. The capabilities start with supercomputers for design and simulation. Circuits can be examined via electrical flow and microscopic examination. These capabilities are useful for developing new devices, particularly for space applications.

microelectronics chip testing magnetic devices↗

Emitter Reconstruction for Cleaved CdSexTe1-x Devices with Cu vs. As Doping

CdTe absorbers have had historically low carrier densities of ~10^14 cm-3 due to the self-compensating nature of copper dopants. Recent advances in group-V (e.g., arsenic) doping have increased this to 10^16-10^17 cm-3, but modeling suggests that the front interface and emitter properties become limiting in this case. By cleaving arsenic- and copper-doped CdTe device stacks at the emitter/absorber interface, we gain the ability to reconstruct emitters with known properties, which will not change during subsequent device processing, and directly test the modeling. By doing so, we find a much larger performance drop in arsenic devices; this is attributed to insufficient electron density in the emitter and increased sensitivity to interface changes due to collapsed depletion width. This work can help guide emitter engineering for highly-doped CdTe devices in both the as-grown-superstrate- and cleaved-substrate configurations.

As-doped↗

High-performance packaging for monolithic microwave and millimeter-wave integrated circuits

Packaging schemes were developed that provide low-loss, hermetic enclosure for advanced monolithic microwave and millimeter-wave integrated circuits (MMICs). The package designs are based on a fused quartz substrate material that offers improved radio frequency (RF) performance through 44 gigahertz (GHz). The small size and weight of the packages make them appropriate for a variety of applications, including phased array antenna systems. Packages were designed in two forms; one for housing a single MMIC chip, the second in the form of a multi-chip phased array module. The single chip array module was developed in three separate sizes, for chips of different geometry and frequency requirements. The phased array module was developed to address packaging directly for antenna applications, and includes transmission line and interconnect structures to support multi-element operation. All packages are fabricated using fused quartz substrate materials. As part of the packaging effort, a test fixture was developed to interface the single chip packages to conventional laboratory instrumentation for characterization of the packaged devices. The package and test fixture designs were both developed in a generic sense, optimizing performance for a wide range of possible applications and devices.

Shalkhauser, K. A.↗

A simple gating technique for high-average-current photo-injectors

This paper describes a simple method that substantially improves the production of gated electron bunch trains by totally suppressing undesired background photoemission between the trains. A device has been designed and tested with a drive laser for proof-of-principle demonstration. The predicted functionality and performance are verified on an Energy-Recovery-Linac (ERL) electron accelerator. The method can find applications whenever the laser pulse repetition rate and length need to be tailored.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Discrete liquid/vapor detectors for use in liquid helium

Simple devices have been constructed and tested which can discriminate between liquid helium and its vapor. The devices are 0.25-mm doped silicon cubes suspended from 0.05-mm-diameter stainless steel and manganin wires. A small current is passed through the device heating it and lowering its resistance. The degree of self-heating is dependent on whether the device is immersed in liquid or is surrounded by vapor. The voltage across the device then indicates the presence of liquid or vapor. The devices are meant to operate in the milligravity environment of space. Tests simulating thick superfluid films which would be present in this case indicate less than 0.3 milliwatt per detector is sufficient to boil away these thick films. The detector response time under these conditions is less than 50 milliseconds.

Dipirro, M. J.↗

Program to design, fabricate, test, and deliver a thermal control-mixing control device, phase 1

The development of a sensor capable of detecting temperature changes as a function of viscosity changes, was completed. This type of sensor, consisting of an orifice bridge circuit, resulted in a device with a threshold above internally generated noise of 0.8C (1.5F). Data were obtained using a noise free Freon source provided by an air pressurized bladder. Tests conducted to operate the sensor from a typical Freon centrifugal pump system employing an air bubble accumulator for noise attentuation disclosed the sensor could be used only to sense temperature changes greater than 3.3C (6F) because of the excessively noisy output. This is attributed to the high frequency-pressure fluctuations in the Freon supply to the sensor.

Thurston, T. S.↗

Intercomparison of Commercially Available Active Radon Measurement Devices in a Discovered Radon Chamber

An unventilated 70 m 3 underground space, with 2.1 m high ceilings and an inner set of concrete walls to damp vibrations, was discovered to have relatively stable radon levels of ~1,080 Bq m -3 over a 1-y period. The addition of radium sources was not required to achieve high and somewhat variable radon levels, as these arise naturally in the space. Several active radon monitoring devices designed for homeowners, radon screeners, radon mitigation professionals, and researchers were tested in the space. These devices were variable in both cost and intended user sophistication. Data were collected at specific time intervals that varied for each device. A cellphone was deployed with an available camera application to periodically capture photographs of the displays of devices not enabled for automatic temporal recording. Attempts were made to alter the radon concentration using fans, radium-laden objects, and radon impermeable sheets. Statistical methods were employed to compare the device's performance under the minor radon transients produced by the addition of 226 Ra sources during the test period. The evaluation of the overall accuracy, noise, and response to transients revealed highly affordable devices that may be useful for future research applications.While unsuitable for precise calibrations at stable radon levels, the space was determined to be adequate as a radon chamber for general research purposes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Testing of a Microfluidic Sampling System for High Temperature Electrochemical MC&A

This report describes the preliminary validation of a high-temperature microfluidic chip system for sampling of electrochemical process salt. Electroanalytical and spectroscopic techniques are attractive candidates for improvement through high-throughput sample analysis via miniaturization. Further, microfluidic chip systems are amenable to micro-scale chemical processing such as rapid, automated sample purification to improve sensor performance. The microfluidic chip was tested to determine the feasibility of the system for high temperature applications and conditions under which microfluidic systems can be used to generate salt droplets at process temperature to support development of material balance and control systems in a used fuel treatment facility. In FY13, the project focused on testing a quartz microchip device with molten salts at near process temperatures. The equipment was installed in glove box and tested up to 400°C using commercial thermal transfer fluids as the carrier phase. Preliminary tests were carried out with a low-melting halide salt to initially characterize the properties of this novel liquid-liquid system and to investigate the operating regimes for inducing droplet flow within candidate carrier fluids. Initial results show that the concept is viable for high temperature sampling but further development is required to optimize the system to operate with process relevant molten salts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Charge-injection-device 2 x 64 element infrared array performance

Three 2 x 64 element Si:Bi accumulation-mode charge-injection-device (CID) arrays were tested at low and moderate background to evaluate their usefulness for space-based astronomical observations. Testing was conducted both in the laboratory and in ground-based telescope IR observations. The devices showed an average readout noise level below 200 equivalent electrons, a peak responsivity of 4 A/W, and a noise equivalent power of 3 x 10 to the -17th W/sq rt Hz. This sensitivity compares well with that of nonintegrating discrete extrinsic silicon photoconductors. The array well capacity was significantly smaller than predicted. The measured sensitivity makes extrinsic silicon CID arrays useful for certain astronomical applications. However, their readout efficiency and frequency response represent serious limitations in low-background applications.

Mckelvey, M. E.↗

Reconfiguring the RUM experiment to test circular scanning with rotating unbalanced-mass devices on gimbaled payloads

This paper describes a ground-based experiment designed to prove the concept of circular scanning a gimbaled payload with rotating unbalanced-mass (RUM) devices. The experiment is a modified version of a similar experiment which demonstrates line and raster scanning with RUM's. In this paper, a description of the experiment hardware is presented and a detailed design of the servos used in scanning is given. A computer simulation model of the entire system is discussed and simulation results are included. These verify the servo designs and show the RUM's to be an extremely power efficient method for circular scanning.

Polites, M. E.↗

Flight Testing of a Low Cost De-Orbiting Device for Small Satellites

Use of small and very small spacecraft is rapidly becoming more common. Methods to intentionally deorbit these spacecraft at the end of useful satellite life are required. A family of mass efficient Roll-Out De- Orbiting devices (RODEO"TM") was developed by Composite Technology Development, Inc. (CTD). RODEO"TM" consists of lightweight film attached to a simple, ultra-lightweight, roll-out composite boom structure. This system is rolled to stow within a lightweight launch canister, allowing easy integration to the small satellite bus. The device is released at the end of useful lifetime and the RODEO"TM" composite boom unrolls the drag sail in a matter of seconds. This dramatically increases the deployed surface area, resulting in the higher aerodynamic drag that significantly reduces the time until reentry. A RODEO"TM" flight demonstration was recently conducted as part of the Colorado Space Grant Consortium's (COSGC) RocketSat-8 program, a program to provide students hands-on experience in developing experiments for space flight. The experiment was ultimately a success and RODEO (trademark) is now ready for future CubeSat missions.

Turse, Dana↗

Development of TRIGA-based experimental device for fiber optics in-core instrumentation testing for VHTRs

Given the harsh environments of high temperature reactors, new in-core instrumentation has to be developed, since existing approaches may fail prematurely in VHTRs. The paper discusses ongoing efforts to support progress of suitable advanced in-core instrumentation technologies and develop an experimental approach for evaluation of their performance within VHTRs via emulation of VHTR in-core conditions in TRIGA reactors. Successful completion of the presented computational analysis concludes the first phase of the project. As demonstrated, it is proposed to use a high temperature furnace with fluence equivalency in operating TRIGA reactors. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗