Search NASA⌕ Search

SEARCH · Search NASA

Results for “fluence”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

Development and Implementation of an Automatic Continuous Online Monitoring and Control Platform for Polymerization Reactions to Sharply Boost Energy and Resource Efficiency in Polymer Manufacturing

The project goal was to create an energy saving paradigm shift in how polymers are manufactured in the 21st century. It used Automatic Continuous Online Monitoring of Polymerization reactions (ACOMP) integrated for the first time with automatic active control to create the innovative ‘ACOMP/Control Interface’, or ‘ACOMP/CI’. ACOMP/CI will begin the transformation from old, inefficient processes into highly evolved, energy and resource efficient ones. The ACOMP platform is broadly applicable to many types of reactions and processes throughout the vast polymer industry. The industry provides materials for sectors such as automotive, aerospace, oil recovery, agriculture, paints, resins, adhesives, pharmaceuticals and therapeutic proteins, optics, electronics, lightweight building materials, and many more. The U.S. chemical industry is one of the last major sectors in which the U.S. has top global stature. It consumes 24% of all U.S. manufacturing energy, produces over $800B of product annually, supports 25% of the U.S. GDP and employs over 6 million people. It is also a major source of GHG emissions. Polymers make up approximately 30% of this sector. It is estimated that annually 60 TBtu of energy could be saved and 3 million tons less of GHG emissions produced by optimizing production in the polyolefin manufacturing sector alone. The project scope included first time design and prototyping of an ACOMP/CI, creation of active reaction controllers, and demonstration of control capabilities on ideal, low concentration polymerization reactions. All these elements of the scope were met, including advances and findings not originally anticipated. Extensions to more complex reactions, beyond the reactor capabilities of the current project ACOMP/CI, such as polyolefins and other high pressure/high temperature reactions, are being proposed in Fall 2017 to CESMII, a DoE based NNMI. The initial proposal was for a three year funded project, but this was reduced to a two year project and budget due to funding constraints. Hence, some of the original plans, such as adaptation of the ACOMP/CI to more relevant industrial processes, such as emulsion and dispersion technologies, could not be carried out. A third year of funding was requested at the end of the project, but DoE did not have resources to grant this. The sub-contractor Fluence Analytics (previously Advanced Polymer Monitoring Technologies, Inc) designed, prototyped, and commissioned a working ACOMP/CI by June 2015. The reaction characteristics to be automatically controlled were i) conversion kinetics, ii) molecular weight, iii) copolymer composition, and iv) simultaneous molecular weight and composition. A two pronged control strategy was used. The Tulane/Fluence group took a basic principles approach that did not rely on kinetic models. The LSU group took a more complex, non-linear model-oriented approach involving complete kinetic descriptions of the reaction system Each of these approaches proved successful in their own way. By April 2016 fully automatic control of conversion and weight average molecular weight, Mw, trajectories was achieved using the Tulane/Fluence (TF) basic principles controller. Similar results were obtained by the LSU non-linear model controller by August 2016. The demonstration system was aqueous free radical polymerization of acrylamide, Am. The control variables were temperature and semi-batch feed to the reactor of Am monomer and initiator. A demonstration of active manual conversion control in an industrial process using high solids in inverse emulsion polymerization of Am was achieved. During Summer 2016 the TF controller was used in conjunction with a chain transfer agent, another control variable, to automatically produce multi-modal molecular weight distributions, MWD, in a single reactor. Industrially, multi-modal MWD are produced by mixing products made in separate reactors, requiring significant extra time, energy, and reactor resources. Recognizing the industrial potential a patent on automatic production of multi-modal polymers was filed, and DoE acknowledged. In Fall 2016 the TF team developed a basic principles controller for copolymer composition and demonstrated it on aqueous free radical copolymerization of comonomers Am and styrene sulfonate, SS. TF then fused the Mw and composition controllers to achieve simultaneous control of both Mw and copolymer composition trajectories. Numerous simultaneous trajectories were demonstrated, including a trimodal composition distribution with constant Mw. Meanwhile, the LSU group developed a Kalman filter to improve the results of their automatic Mw and conversion controller and successful tests were made. During the project the TF team developed a means of computing full MWD during polymer synthesis without need for any chromatographic separation, based on model distributions. This means the polymer product is ‘born characterized’ and this can eliminate post-manufacture analytical laboratory quality control. TF filed a joint patent application on this new approach to chromatography-free determination of MWD with acknowledgment to DoE. The Tulane group obtained a 60MHz NMR during the project and recently completed the first work on separating three comonomers, Am, SS, and Na-acrylate, with a first demonstration of terpolymer composition control with the TF basic principles controller. Widespread dissemination of ACOMP/CI in the polymer manufacturing sector will bolster DoE goals of energy efficiency and reduced GHG emissions: The ability to monitor and actively control polymerization reactions will lead to more efficient use of energy and non-renewable resources, plant and labor time, increase the safety of manufacturing personnel, and will enhance product quality and lead to feasibility of manufacturing of polymers currently too complex for industrial scale production, while leading to less GHG emissions per kilo of product, and allowing for increased U.S. competitiveness in this enormous manufacturing sector. When ACOMP/CI is expanded to the polyolefin industry it is estimated that 60 TeraBTU/year of energy can be saved. Much of this saving is anticipated to come from optimized control of grade changeovers in steady state reactors and maintenance of steady states. Conclusions: ACOMP’s ability to provide continuous realtime data streams of measured polymer and reaction characteristics made it possible, for the first time, to directly and automatically control free radical polymerization reactions. An industrial client of Fluence Analytics has requisitioned the first ACOMP/CI which uses the TF basic principles controller. This sets the stage for FA to add control features to the ACOMP systems it has begun to install on the industrial scale beginning in 2014. Recommendations: This successful project was mainly limited to ideal polymerizations not of an industrial sort. The most energy intensive portion of polymer manufacturing is polyolefins. Adoption of ACOMP/CI to this enormous industrial sector faces the enormous challenges of high temperature, high pressure continuous sampling and high temperature sensor operation to obtain the continuous data needed for direct reaction control. The project team has a strategy for achieving this ambitious goal and will present it in Fall 2017 as a proposal to CESMII/DoE. It is recommended that this upcoming proposal be funded in order to make full use of the achievements of this just ended DoE project as the next step towards making polyolefin ACOMP/CI an energy saving reality. It is projected that ACOMP/CI can have its first polyolefin testbed demonstrations within two years of beginning the proposed project.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Calculational Model of the Radiation Calibration Lab (RCL) and the Neutron Measurements performed at the Facility, with a 252 Cf Source

Calibration of detectors measuring gamma, neutron, alpha and beta radiation, and of personal dosimeters used at Lawrence Livermore National Laboratory (LLNL), is performed at the Radiation Calibration Lab (RCL). The calibrations done with a standard calibrated 252 Cf source are a function of the energy spectra, fluence and dose of the source. A detailed calculational model of the RCL has been carried out with the MCNP6 code. The calculations have also reproduced quite well the measurements of the fluence and dose rates for the bare and moderated 252 Cf source carried out by R. Radev using the Rospec Spectrometer and by Clark and Wilson using a Passive Neutron Spectrometer. The importance of having the calculational model of the RCL facility is to calculate the dose rates expected for a given planned measurement, optimizing the choice of detectors, design and shielding materials before the actual measurement are carried out, resulting in a more efficient and time saving measurement. Furthermore, an accurate model of the facility allows to detect possible problems with the measurement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis of the IBL and LBNL irradiated PIN and PN diodes

This report is a follow-up to the previous report on the difference between high fluence, high and low flux irradiations. There was a discrepancy in the data for the LBNL irradiated S5821 PIN diodes. There were diodes irradiated in the two batches (high and low flux) with the same flux and fluence for reference (lell ions/cm 2 /shot and 5, 10, and 20 ions/cm 2 total flux). Although these diodes should have the same electrical characteristics their leakage currents were different by a factor of 5-6 (batch 2 was larger). Also, the C-V measurements showed drastically different results. It was speculated that these discrepancies were due to one of the following two reasons: 1. Different times elapsed between radiation and characterization. 2. Different areas were irradiated (roughly half of the diodes were covered during irradiation). To address the first concern, we annealed the devices according to the ASTM standard [1]. The differences remained the same. To determine the irradiated area, we performed large area IBIC scans on several devices. Error! Reference source not found. below shows the IBIC maps of two devices one from each batch. The irradiated areas are approximately the same.

42 ENGINEERING↗

AGR 3/4 Irradiation Test Final As Run Report, Revision 1

Several fuel and material irradiation experiments have been planned for the Idaho National Laboratory Advanced Reactor Technologies Technology Development Office Advanced Gas Reactor Fuel Development and Qualification Program (referred to as the INL ART TDO/AGR fuel program hereafter), which supports the development and qualification of tristructural-isotropic (TRISO) coated particle fuel for use in HTGRs. The goals of these experiments are to provide irradiation performance data to support fuel process development, qualify fuel for normal operating conditions, support development and validation of fuel performance and fission product transport models and codes, and provide irradiated fuel and materials for post irradiation examination and safety testing (INL 05/2015). AGR-3/4 combined the third and fourth in this series of planned experiments to test TRISO coated low enriched uranium (LEU) oxycarbide fuel. This combined experiment was intended to support the refinement of fission product transport models and to assess the effects of sweep gas impurities on fuel performance and fission product transport by irradiating designed-to-fail fuel particles and by measuring subsequent fission metal transport in fuel-compact matrix material and fuel-element graphite. The AGR 3/4 fuel test was successful in irradiating the fuel compacts to the burnup and fast fluence target ranges, considering the experiment was terminated short of its initial 400 EFPD target (Collin 2015). Out of the 48 AGR-3/4 compacts, 42 achieved the specified burnup of at least 6% fissions per initial heavy-metal atom (FIMA). Three capsules had a maximum fuel compact average burnup < 10% FIMA, one more than originally specified, and the maximum fuel compact average burnup was <19% FIMA for the remaining capsules, as specified. Fast neutron fluence fell in the expected range of 1.0 to 5.5 × 10 25 n/m 2 (E >0.18 MeV) for all compacts. In addition, the AGR-3/4 experiment was globally successful in keeping the temperature in the twelve capsules relatively flat in a range of temperatures suitable for the measurement of fission product diffusion in compact matrix and structural graphite materials.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Fracture Toughness Characterization of Highly irradiated Reactor Pressure Weld from the ATR-2 Experiment

The UCSB ATR-2 irradiation experiment is designed to generate a new database on a wide variety of irradiated reactor pressure vessel (RPV) steels to fill a critical gap in predicting high fluence embrittlement for extended plant operation up to 80 years. A major focus in this experiment is to characterize the effects of irradiation temperature, neutron flux and fluence, and alloy chemistry on MNSP evolution, and model how these features impact hardening and embrittlement, manifested as shifts in ductile-to-brittle transition temperature. As part of these efforts, disk compact tension (DCT) specimens of three representative materials were included in the ATR-2 experiment to have direct measurement of transition fracture toughness shift and, thus, to have some benchmark data to compare outcoming predictive models with actual fracture toughness shifts. In addition, the attempts would be made to use these fracture toughness data to address the potential effect of high dose irradiation on the shape of the Master Curve for highly embrittled RPV material.This report provides data for the fracture toughness characterization of highly embrittled weld from Palisades steam generator.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Long Baseline Neutrino Experiment (LBNE) Target Material Radiation Damage from Energetic Protons of the Brookhaven Linear Isotope Production (BLIP) Facility

In search of a low-Z pion production target for the Long Baseline Neutrino Facility (LBNF) of the Deep Underground Neutrino Experiment (DUNE) various grades of graphite were irradiated with 140-180 MeV protons to fluence up to ~6 10 20 cm -2 and irradiation temperatures in the range of 100-200oC. The objective of the irradiation experiment was to assess the radiation induced changes in the graphite onset by its interaction with energetic protons and deduce some measure of performance and survivability under the design conditions of LBNF. A multi-faceted post-irradiation evaluation was conducted to both qualify and quantify the induced material property changes. These studies included dimensional stability and thermal expansion, damage annealing via thermal cycling, high temperature post-irradiation annealing to mimic irradiation at elevated temperatures, stress-strain behavior, oxidation contribution to the postirradiation analysis, potential influence of the argon atmosphere under which irradiation took place, and lattice evolution. Dilatometry-based techniques were coupled with ultrasound-based annealing methodologies as well as DSC and TGA analyses. X-ray diffraction experiments assessed the lattice parameter changes and SEM analyses were used to study the different graphite grade structures. The multi-faceted post-irradiation evaluation, in conjunction with off-beam analyses, revealed some important facts regarding the choice of a graphite grade. Specifically, it was observed that the microstructure of a grade plays an important role in its dimensional stability. X-ray diffraction data indicated variability in basal plane spacing prior to irradiation with POCO d 002 =3.3833 Å, IG-430 d 002 =3.36814 Å and R7650 d 002 =3.37944 Å. Isotropic graphite grades such as POCO and IG-430 are confirmed to undergo microstructural shrinking under irradiation. All four irradiated graphite grades experience irradiation-induced creep leading to increased Young’s modulus with changes as high as 50% that varies with microstructure. X-ray diffraction on irradiated graphite confirmed previously made observations where under both energetic protons as well as fast neutrons of fluence > 5 10 20 cm -2 and at temperatures around 200°C acceleration of the effects on both the micro-and macrostructure is observed. Amongst the irradiated grades POCO graphite showed tendency to increase crystallinity order but also shows turbostratic state resulting from the interaction of its lattice with protons. This report presents and discusses the details of the irradiation experiment and the results of the postirradiation evaluation with main objective the assessment of the applicability and survivability of the selected four graphite grades as high-power accelerators pion production targets where the structural integrity, density reduction, dimensional and physical property stability are of paramount importance.

43 PARTICLE ACCELERATORS↗

Used Fuel Storage Monitoring Using Helium-4 Scintillation Fast Neutron Detectors and Neutron Spectral Analysis

This project aimed to address the technology gap in the reliable methods to verify contents of sealed dry storage casks for spent nuclear fuel. Helium-4 gas scintillation neutron detectors was proposed to be developed into a neutron spectroscopy and imaging system for nuclear security and safeguards applications. 4 He gas is significantly more available than 3 He gas and it has unique advantages such as low gamma interaction probability and direct detection of fast neutrons. Due to the sheer amount of fissile materials in a single dry cask, there is a significant neutron fluence emitted whose energies range from thermal to uncollided high-energy neutrons suitable for the detection capability of the 4 He detectors. Our project demonstrated the first ever neutron spectroscopic capabilities using 4 He detectors, explored novel detector design and performed detector characterization. It further qualified the detectors for use in various applications including high-flux environments with significant gamma-fluence. Computer simulations were used to test various large cask measurement system designs and tests, beyond the compact prototype system and laboratory measurements exploring the feasibility of the neutron spectroscopic approach. Although some cask-characterization methods proved unfeasible, alternative characterization methods using the He-4 detectors were explored and generated promising results.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Diamond Beam Monitor for Medical Dosimetry (Final Report)

In this technical report we will discuss the efforts to develop diamond radiation detectors as dosimeters for therapeutic proton beam diagnostics, measuring the proton fluence as well as the beam profiles in high energy proton beams. The detector performance was recorded as the ion beam induced current (IBIC) from the 800MeV proton beam using different beam conditions. The lifetime of the detectors was also measured by monitoring the real-time detector response changes during the extensive proton irradiation. All irradiated diamond detectors were then characterized using synchrotron X-rays, by measuring the detector performance including I-V curves, response maps, flux scan and timing. The device performance decay was further studied with several simulation packages (SRIM\TRIM and FLUKA), and radiation damage mechanism was investigated by using experimental data and simulation models. Several impact factors (fluence rate, total dose, contact materials and cooling time) were discussed and the radiation effect on carrier transport was studied.

36 MATERIALS SCIENCE↗

14 MeV DT Neutron Test Facility at the Sandia Ion Beam Laboratory

A recently completed LDRD project has provided a new facility at Sandia for testing effects of energetic neutrons on electronic components. 14 MeV neutrons are produced with a deuterium ion beam onto a thin-film tritide target. The goal of the project was to increase the neutron fluence to levels needed for radiation effects testing and qualification. This goal was achieved through two technical advances. First, a new multi-layer target concept was developed to reduce the rate of tritium loss from the target by isotope exchange, thereby reducing tritium usage and increasing target lifetime. The second advance was the construction of a new test chamber designed to maximize neutron flux at test locations. Together, these increased the available neutron fluence by several orders of magnitude. This new capability is being used in tests for Sandia nuclear weapon programs, evaluation of commercial parts such as highly-scaled CMOS SRAM lCs, and tests of new devices under development at Sandia such as lll-V HBTs, gallium nitride high-voltage diodes, and for fundamental studies of physical mechanisms of device failure.

36 MATERIALS SCIENCE↗

Ex-Core Radiation Transport Modeling with VERA User Manual

It is important to be able to accurately predict the neutron flux outside the immediate reactor core for a variety of safety and material analyses. Monte Carlo radiation transport calculations are required to produce these high–fidelity ex-core responses. The Virtual Environment for Reactor Applications (VERA) provides the automated capability to launch independent Shift fixed-source and eigenvalue Monte Carlo (MC) calculations for user-specified state points during a standard Virtual Environment for Reactor Applications (VERA) calculation. VERA couples MPACT with COBRA-TF (CTF) to Shift to perform ex-core tallies for multiple state points concurrently, with each component capable of parallel execution on independent processor domains. In these ex-core calculations, MPACT is coupled to CTF and performs the in-core depletion and heat transfer calculation, followed by a fixed-source Shift transport calculation including ex-core regions to produce ex-core responses. The fission source, fuel pin temperatures, moderator temperature and density, boron concentration, and fuel pin depleted isotopic compositions can be transferred to Shift from the MPACT calculation. Specifically, VERA performs fluence calculations in the core barrel outward to the end of the pressure vessel and detector response calculations in ex-core detectors. It also performs the requested tallies in any user-defined ex-core regions. VERA takes advantage of the General Geometry (GG) package in Shift. This gives VERA the flexibility to explicitly model features outside the core barrel, including detailed vessel models, detectors, and power plant details. A very limited set of experimental and numerical benchmarks is available for ex-core simulation comparison. The Consortium for Advanced Simulation of Light Water Reactors has developed a set of ex-core benchmark problems to include as part of the VERA verification and validation set of problems. The ex-core capability in VERA has been tested on small representative assembly problems, multi-assembly problems, as well as quarter-core and full-core problems. VERA View has also been extended to visualize these vessel fluence results from VERA. This manual serves to present a guide to VERA users about the methodology behind ex-core calculations and the details of input, output, and analysis of results from these calculations. Details in this version of the manual are based on features in VERA 4.0.1.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

TMS XTRRA experiments on NIF

The study of x-ray induced rapid heating and the resulting material responses - (thermomechanical shock (TMS) and thermo-structural response (TSR)) - is important to our understanding of material behavior in extreme environments. A series of high conversion efficiency (XRCE) x-ray sources have been developed for the NIF laser facility ranging in fluence and spectral content. In conjunction with source development, we have developed a new XTRRA (X-ray Transport and Radiation Response Analysis) test cassette to hold a set of samples, each at equal distance from target chamber center (TCC) where the x-ray source is placed. Design and performance details of the x-ray sources is discussed elsewhere. Here, we describe the development and use of this TMS XTRRA test cassette. The XTRRA test cassette is a snout mounted on a NIF Diagnostic Instrument Manipulator (DIM) designed to position six samples equidistant from the x-ray source to assure uniform irradiation of all samples. Photon Displacement interferometry (PDI) is used to measure the displacement of the rear surface of each sample resulting from x-ray exposure on the front of the sample. This will help determine the x-ray generated impulse on the sample. The samples are retrieved from the snout after the shot for inspection and post-shot analysis including the measurement of sample ablated mass and engineering tests examining changes in the material structure. The data from experiments are compared to predictions from LLNL’s ASC codes and used to inform models implemented in these codes. Thus, XRCE x-ray sources with the XTRRA snout at the National Ignition Facility (NIF) laser at the Lawrence Livermore National Laboratory [1,2] provide the ability to expose a broad range of material samples directly to high x-ray fluence, measure shock transits, and recover the sample for further analysis post-shot.

36 MATERIALS SCIENCE↗

Response of GaN-Based Semiconductor Devices to Ion and Gamma Irradiation

GaN has electronic properties that make it an excellent material for the next generation of power electronics; however, its radiation hardening still needs further understanding before it is used in radiation environments. In this work we explored the response of commercial InGaN LEDs to two different radiation environments: ion and gamma irradiations. For ion irradiations we performed two types of irradiations at the Ion Beam Lab (IBL) at Sandia National Laboratories (SNL): high energy and end of range (EOR) irradiations. For gamma irradiations we fielded devices at the gamma irradiation facility (GIF) at SNL. The response of the LEDs to radiation was investigated by IV, light output and light output vs frequency measurements. We found that dose levels up to 500 krads do not degrade the electrical properties of the devices and that devices exposed to ion irradiations exhibit a linear and non- linear dependence with fluence for two different ranges of fluence levels. We also performed current injection annealing studies to explore the annealing properties of InGaN LEDs.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Thermo-Mechanical Shock, X-Ray Transport and Radiation Response Analysis Experiments on NIF

The study of x-ray induced rapid heating and the resulting material responses - (thermomechanical shock (TMS) and thermo-structural response (TSR)) - is important to our understanding of material behavior in extreme environments. A series of high conversion efficiency (XRCE) x-ray sources have been developed for the NIF laser facility ranging in fluence and spectral content. In conjunction with source development, we have developed a new XTRRA (X-ray Transport and Radiation Response Analysis) test cassette to hold a set of samples, each at equal distance from target chamber center (TCC) where the x-ray source is placed. Design and performance details of the x-ray sources is discussed elsewhere. Here, we describe the development and use of this TMS XTRRA test cassette. The XTRRA test cassette is a snout mounted on a NIF Diagnostic Instrument Manipulator (DIM) designed to position six samples equidistant from the x-ray source to assure uniform irradiation of all samples. Photon Displacement interferometry (PDI) is used to measure the displacement of the rear surface of each sample resulting from x-ray exposure on the front of the sample. This will help determine the x-ray generated impulse on the sample. The samples are retrieved from the snout after the shot for inspection and post-shot analysis including the measurement of sample ablated mass and engineering tests examining changes in the material structure. The data from experiments are compared to predictions from LLNL’s ASC codes and used to inform models implemented in these codes. Thus, XRCE x-ray sources with the XTRRA snout at the National Ignition Facility (NIF) laser at the Lawrence Livermore National Laboratory provide the ability to expose a broad range of material samples directly to high x-ray fluence, measure shock transits, and recover the sample for further analysis post-shot.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Requirements Documents for the Large Mechanical Parts Precision Cleaner (LMPPC) in the Optics Assembly Building (OAB)

The National Ignition Facility (NIF) is the world's largest energetic laser whose missions include sresearch in inertial confinement fusion, experiments for the Stockpile Stewardship, and other high fluence laser research. Due to the high fluence of lasers, extreme environmental conditions, and radiation presence, all mechanical parts (metal, plastic, etc.) installed on NIF must be precision cleaned. Precision cleaned parts are also required in supporting facilities like the Optics Processing Facility (OPF). Small debris inside the laser beams or on optics can cause optic damage, interfere with diagnostics, and interfere with experiments.

42 ENGINEERING↗

VERA User's Guide for Ex-core Applications

The Virtual Environment for Reactor Applications, or VERA, allows users to set up models to calculate time-dependent and fully coupled solutions for ex-core quantities of interest such as vessel and coupon fluence, and detector responses for multiple statepoints and cycles. MPACT and COBRA-TF together perform in-core transport calculations with temperature feedback while Shift performs the fluence and detector response calculations in the ex-core region. The in-core region is modeled using VERA’s native input format and the ex-core region is defined using Shift’s general geometry package, also known as Omnibus General Geometry. Fixed source ex-core calculations with Shift can be run in forward mode without advanced variance reduction (VR) methods, or with Consistent Adjoint Driven Importance Sampling (CADIS), which is an automated VR method. This document serves as a guide for setting up inputs, running ex-core calculations and post-processing the results.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Distances to Prompt Effects for a Nuclear Device

In 2010, nuclear weapon effects experts at Sandia National Laboratories (SNL) were asked to provide a quick reference document containing estimated prompt nuclear effects. This report is an update to the 2010 document that includes updated model assumptions. This report addresses only the prompt effects associated with a nuclear detonation (e.g., blast, thermal fluence, and prompt ionizing radiation). The potential medium- and longer-term health effects associated with nuclear fallout are not considered in this report because, in part, of the impracticality of making generic estimates given the high dependency of fallout predictions on the local meteorological conditions at the time of the event. The results included in this report also do not consider the urban environment (e.g., shielding by or collapse of structures) which may affect the extent of prompt effects. It is important to note that any operational recommendations made using the estimates in this report are limited by the generic assumptions considered in the analysis and should not replace analyses made for a specific scenario/device. Furthermore, nuclear effects experts (John Hogan, SNL, and Byron Ristvet, Defense Threat Reduction Agency (DTRA)) have indicated that the accuracy of effects predictions below 0.5 kilotons (kT) or 500 tons nuclear yield have greater uncertainty because of the limited data available for the prompt effects in this regime. The Specialized Hazard Assessment Response Capability (SHARC) effects prediction tool was used for these analyses. Specifically, the NUKE model within SHARC 2021 Version 10.2 was used. NUKE models only the prompt effects following a nuclear detonation. The algorithms for predicting range-to-output data contained within the NUKE model are primarily based on nuclear test effects data. Probits have been derived from nuclear test data and the U.S. Environmental Protection Agency (EPA) protective action guides. Probits relate the probability of a hazard (e.g., fatality or injury) caused by a given insult (e.g., overpressure, thermal fluence, dose level). Several probits have been built into SHARC to determine the fatality and injury associated with a given level of insult. Some of these probits differ with varying yield. Such probits were used to develop the tables and plots in this report.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

FY21 Progress of the Oak Ridge Health Physics Research Reactor CAAS Benchmark Evaluation [Slides]

The FY21 version of the evaluation, focusing on element 57 dose at 3 meters, was presented at the ICSBEP Technical Review Group meeting in October 2021 and was not accepted for 2022 publication in the handbook. The main issue was identified and replacement of the element 57 neutron dose benchmark metric by neutron fluence (closer to what was measured) is required. A subgroup was formed, confident for the updated neutron fluence evaluation to be accepted in the ICSBEP handbook. The updated evaluation will be presented again at the 2022 ICSBEP TRG for publication in the 2023 handbook.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Simulation Studies on the Interactions of Electron Beam with Wastewater

The manufactured chemical pollutants, like 1,4 dioxane and PFAS (per- and polyfluroralkyl substances), found in the underground water and/or drinking water are challenging to be removed or biodegraded. Energetic electrons are capable of mediating and removing them. This paper utilizes FLUKA code to evaluate the beam-wastewater interaction effects with different energy, space and divergence distributions of the electron beam. With 8 MeV average energy, the electron beam exits from a 0.0127 cm thick titanium window, travels through a 4.3 cm distance air and a second 0.0127 cm thick stainless water container window with 2.43 cm radius, and finally is injected into the water area, where the volume of water is around 75 cubic cm. The distribution parameters of the electron beam are from the GPT (General Particle Tracer) simulations for UITF (Upgraded Injector Test Facility) in Jefferson lab. By varying the distributions, several measurements including the dose (or energy deposition) distribution, electron fluence, photon fluence are scored and compared. Taking the comparisons into consideration, this paper is aiming to find better electron beams for the wastewater irradiation.

Li, X.↗