Search NASA⌕ Search

SEARCH · Search NASA

Results for “heterogeneous processing system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

Extrapolation of space weathering processes to other small solar system bodies

A diverse range of processes were invoked as the dominant factor or as important contributory factors in the modification of the optical surface and regolith of the moon. These include impact vitrification by large and small projectiles, solar wind implantation and the reduction of oxidized iron during energetic events, sputtering and crystal lattice damage by energetic cosmic rays, shock metamorphism of minerals, mixing of diverse lithologies by impacts, and contamination by external materials. These processes are also potentially important on the rocky surfaces of other small solar system bodies. For icy bodies, several additional processes are also possible, including formation of complex organic compounds from methane and ammonia-bearing ices by ultraviolet irradiation and the condensation of vapor species to form frost layers in the polar or cooler regions of objects at appropriate heliocentric distances. The lunar case, even when completely understood, will not extend in a simple linear fashion to other small rocky objects, nor will the optical surfaces of those objects all be affected to the same degree by each process. The major factors that will control the relative efficacy of a possible mechanism include the efficiency of ejecta retention and the degree to which the regolith materials experience multiple events (primarily a function of body size, escape velocity, and impactor velocities); the mean duration of typical regolith particle exposure at the optical surface and within reach of the micrometeorite, cosmic ray, solar wind, or UV fluxes (a function of the rate and scale of regolith mixing, production, and removal processes); the incident flux of solar (low energy) cosmic rays, solar wind, or UV radiation (inverse square of heliocentric distance) or of galactic (high energy) cosmic rays (slowly increasing flux with heliocentric distance); and the compositional and mineralogical nature of the surface being affected. In general, those processes that depend upon either the retention of impact ejecta or on the presence of multigenerational regoliths should be substantially less effective on smaller bodies with lower escape velocities. However, there are important exceptions to this generalization. For example, a process that involves the hypervelocity impact of small particles into a fine-grained regolith may be able to effectively retain highly shocked or melted material due to the nature of shock wave propagation in such a heterogeneous material.

Gaffey, M. J.↗

Boosting Big National Lab Data

Introduction: Big data. Love it or hate it, solving the world’s most intractable problems requires the ability to make sense of huge and complex sets of data and do it quickly. Speeding up the process – from hours to minutes or from weeks to days – is key to our success. One major source of such big data are physical experiments. As many will know, these physical experiments are commonly used to solve challenges in fields such as energy security, manufacturing, medicine, pharmacology, environmental protection and national security. Experiments use different instruments and sensor types to research for example the validity of new drugs, the base cause for diseases, more efficient energy sources, new materials for every day goods, effective methods for environmental cleanup, the optimal ingredients composition for chocolate or determine how to preserve valuable antics. This is done by experimentally determining the structure, properties and processes that govern biological systems, chemical processes and materials. The speed and quality at which we can acquire new insights from experiments directly influences the rate of scientific progress, industrial innovation and competitiveness. And gaining new groundbreaking insights, faster, is key to the economic success of our nations. Recent years have seen incredible advances in sensor technologies, from house size detector systems in large experiments such as the Large Hadron Collider and the ‘Eye of Gaia’ billion pixel camera detector to high throughput genome sequencing. These developments have led to an exponential increase in data volumes, rates and variety produced by instruments used for experimental work. This increase is coinciding with a need to analyze the experimental results at the time they are collected. This speed is required to optimize the data taking and quality, and also to enable new adaptive experiments, where the sample is manipulated as it is observed, e.g. a substance is injected into a tissue sample and the gradual effect is observed as more of the substance is injected, providing better insights into the natural processes that are occurring, as well as result driven sampling adjustment to capture particularly interesting features --- as they emerge. The Department of Energy’s Pacific Northwest National Laboratory (PNNL) is recognized for it’s expertise in the development of new measurement techniques and their application to challenges of national importance. So it was obvious to us to address the need for in-situ analysis of large scale experimental data. We have a wide range of experimental instruments on site, in facilities such as DOE’s national scientific user facility, the William R. Wiley Environmental Molecular Sciences Laboratory (EMSL). Commonly, scientists would create an individual analysis pipeline for each of those instruments; but even the same type of instrument would not necessarily share the same analysis tools. With the rapid increase of data volumes and rates we were facing two key challenges: how to bring a wider set of capabilities to bear to achieve in-situ analysis, and how to do so across a wide range of heterogeneous instruments at affordable costs and in a reasonable timeframe. We decided to take an unconventional approach to the problem, rather than developing customized, one-off solutions for specific instruments we wanted to explore if a more common solution could be found that would go beyond shared, basic infrastructures such as data movement and workflow engines.

97 MATHEMATICS AND COMPUTING↗

Spectro-Microscopy Studies of Atmospheric Particles

Our project investigated composition and physical properties of individual atmospheric particles collected in field campaigns organized by the DOE Atmospheric Systems Research and Atmospheric Radiation Measurement (ASR/ARM) programs, such as the Green Ocean Amazon (GoAmazon, 2014/5), the Holistic Interactions of Shallow Clouds, Aerosols, and Land-Ecosystems (HI-SCALE, 2016/7), the Aerosol and Cloud Experiment in the Eastern North Atlantic (ACE-ENA, 2017/8), the Aerosol–Ice Formation Closure Pilot Study (AEROICESTUDY, 2019) and in additional small-scale supporting field experiments focused on the investigation of the light-absorbing (aka brown carbon) atmospheric particles. In these studies, we investigated the contribution of natural and anthropogenic sources to populations of atmospheric particles during representative atmospheric conditions; characterized particle composition and evaluated their hygroscopic properties and propensity to act as cloud condensation nuclei (CCN) and ice nuclei (IN); correlated typical particle-type and mixing state characteristics with real-time measurements in the areas of studies. We used multi-modal spectro-microscopy techniques to examine elemental and molecular composition, mixing state, size, and higher order morphology for individual particles. Specifically, we used computer-controlled scanning electron microscopy and X-ray microanalysis for quantitative analysis of particle elemental composition, and we used transmission electron microscopy to provide additional information on the distribution of different components within individual particles (particle heterogeneity). We used synchrotron-based scanning transmission X-ray microscopy for quantitative description of the mixing state and molecular bonding of carbon in particles. The particle composition, mixing state, and morphology from analyzed periods was then combined with the real-time ARM measurements of aerosol size distribution, CCN concentration, hygroscopicity, and aerosol bulk composition. Combined together, results of our studies allowed us to assess the major particle sources (biogenic vs. anthropogenic, primary vs secondary) and gain insight into the atmospheric processing of aerosol particles resulting from condensation, coagulation, oxidative aging, and cloud processing. In collaboration with other scientists involved in field campaigns, we carried out statistical analysis of particle properties and their source-specific contributions to regional aerosol loading under representative air mass, meteorological, and cloud conditions.

scanning transmission X-ray microscopy↗

Metal-silicate catalysts: Single site, mesoporous systems without templates

The textural properties of a family of silicate and mixed metal-silicate materials prepared by a nonaqueous sol-gel reaction involving the cubic silicate Si 8 O 20 (SnMe 3 ) 8 and metal chlorides MCl 4 (M = Si, Ti, Zr) cross-linking reagents are described. Nitrogen adsorption isotherm data is presented and surface area and pore size distribution analyses for several examples of these materials are developed and correlated with the ratio of cross-linking reagent and the cubic silicate building block at the time of synthesis. Significant surface area and pore size distributions that shift to higher pore diameters are observed as the ratio of cross-linking reagent-to-cubic building block increases. A simple strategy for simultaneously controlling the porosity of these matrices while homogeneously dispersing identical metal centers on their surfaces for next generation catalysts is described.

36 MATERIALS SCIENCE↗

Pushing sensor network computation to the edge

Sensor Networks consist of multiple devices equipped with some sensing apparatus. The devices in the network may be homogeneous or heterogeneous, yet they will coordinate in order to accomplish a pre-defined task. With the rising interest in the use of Sensor Networks in various applications, the sensor nodes need to subsist in a dynamic environment and react in a timely fashion to environmental stimuli. Unfortunately, the current paradigm in Sensor Network relies on static tasking of the nodes to support a common task; which ultimately leads to deployment of various networks to cover a common area so long as the tasks and owners of these networks differ. Straying away from this paradigm, our work introduces a framework to enable nodes to support dynamic tasking in a dynamic environment by pushing computation to the edge through FPGA-based reconfigurable nodes with increased processing power. Furthermore, we contend that the sensing apparatus available on the nodes limits the range of applications that such nodes will support. As such, reconfigurability of the nodes can yield the most efficient and responsive hardware implementation of algorithms to support common tasks of applications. The benefits of our approach are highlighted through the introduction of a target-tracking node that is reconfigurable and provides increased response time to stimuli.

47 OTHER INSTRUMENTATION↗

Ontologizing health systems data at scale: making translational discovery a reality

Common data models solve many challenges of standardizing electronic health record (EHR) data but are unable to semantically integrate all of the resources needed for deep phenotyping. Open Biological and Biomedical Ontology (OBO) Foundry ontologies provide computable representations of biological knowledge and enable the integration of heterogeneous data. However, mapping EHR data to OBO ontologies requires significant manual curation and domain expertise. We introduce OMOP2OBO, an algorithm for mapping Observational Medical Outcomes Partnership (OMOP) vocabularies to OBO ontologies. Using OMOP2OBO, we produced mappings for 92,367 conditions, 8611 drug ingredients, and 10,673 measurement results, which covered 68–99% of concepts used in clinical practice when examined across 24 hospitals. When used to phenotype rare disease patients, the mappings helped systematically identify undiagnosed patients who might benefit from genetic testing. By aligning OMOP vocabularies to OBO ontologies our algorithm presents new opportunities to advance EHR-based deep phenotyping.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

SU-E-T-188: Film Dosimetry Verification of Monte Carlo Generated Electron Treatment Plans

Purpose: The purpose of this study was to compare dose distributions from film measurements to Monte Carlo generated electron treatment plans. Irradiation with electrons offers the advantages of dose uniformity in the target volume and of minimizing the dose to deeper healthy tissue. Using the Monte Carlo algorithm will improve dose accuracy in regions with heterogeneities and irregular surfaces. Methods: Dose distributions from GafChromic{sup ™} EBT3 films were compared to dose distributions from the Electron Monte Carlo algorithm in the Eclipse{sup ™} radiotherapy treatment planning system. These measurements were obtained for 6MeV, 9MeV and 12MeV electrons at two depths. All phantoms studied were imported into Eclipse by CT scan. A 1 cm thick solid water template with holes for bonelike and lung-like plugs was used. Different configurations were used with the different plugs inserted into the holes. Configurations with solid-water plugs stacked on top of one another were also used to create an irregular surface. Results: The dose distributions measured from the film agreed with those from the Electron Monte Carlo treatment plan. Accuracy of Electron Monte Carlo algorithm was also compared to that of Pencil Beam. Dose distributions from Monte Carlo had much higher pass rates than distributions from Pencil Beam when compared to the film. The pass rate for Monte Carlo was in the 80%–99% range, where the pass rate for Pencil Beam was as low as 10.76%. Conclusion: The dose distribution from Monte Carlo agreed with the measured dose from the film. When compared to the Pencil Beam algorithm, pass rates for Monte Carlo were much higher. Monte Carlo should be used over Pencil Beam for regions with heterogeneities and irregular surfaces.

60 APPLIED LIFE SCIENCES↗

PRIMA-X - Performance Retargeting of Instrumentation, Measurement, and Analysis Technologies for Exascale Computing

The PRIMA-X (Performance Retargeting of Instrumentation, Measurement, and Analysis Technologies for Exascale Computing) project is the successor of the DOE PRIMA (Performance Refactoring of Instrumentation, Measurement, and Analysis Technologies for Petascale Computing) project, which addressed the challenge of creating a core measurement infrastructure that would serve as a common platform for both integrating leading parallel performance systems (notably TAU and Scalasca) and developing next-generation scalable performance tools. The PRIMA-X project shifts the focus away from refactorization of robust performance tools towards a re-targeting of the parallel performance measurement and analysis architecture for extreme scales. The massive concurrency, asynchronous execution dynamics, hardware heterogeneity, and multi-objective prerequisites (performance, power, resilience) that identify exascale systems introduce fundamental constraints on the ability to carry forward existing performance methodologies. In particular, there must be a deemphasis of per-thread observation techniques to significantly reduce the otherwise unsustainable flood of redundant performance data. Instead, it will be necessary to assimilate multi-level resource observations into macroscopic performance views, from which resilient performance metrics can be attributed to the computational features of the application. This requires a scalable framework for node-level and system-wide monitoring and runtime analyses of dynamic performance information. Also, the interest in optimizing parallelism parameters with respect to performance and energy drives the integration of tool capabilities in the exascale environment further. Initially, PRIMA-X was a collaborative project between the University of Oregon (lead institution) and the German Research School for Simulation Sciences (GRS). Because Prof. Wolf, the PI at GRS, accepted a position as full professor at Technische Universitaet Darmstadt (TU Darmstadt) starting February 1st, 2015, the work of GRS was continued at TU Darmstadt. This report covers the work at TU Darmstadt after the transition. The first main accomplishment of TU Darmstadt is the development of different techniques to aggregate performance data on the level of threads. TU Darmstadt evaluated different schemes designed at GRS during the first phase of this project and integrated them into Score-P, a widely used performance measurement framework for HPC applications. The second main accomplishment is a substantial increase of Score-P’s scalability, achieved by improving its internal representation of the underlying system. Third, we extended our performance-modeling tool Extra-P to automatically create models with more than one input parameter (e.g., process count and input size), which was previously impossible. These models allow the performance behavior of an application to be extrapolated to larger machines. Specific applications of the new multi-parameter capability realized in this project include modeling the isoefficiency function of task-based applications and a novel co-design methodology. Further extensions of Extra-P comprise online modeling functionality, automatic refinement of the model search space, and segmented performance modeling. Further contributions include new locality metrics for both shared- and distributed-memory applications, a new way of measuring the impact of inter-application inference on the execution time of an application, and finally an automatic method that selects appropriate OpenMP constructs for the parallelization of sequential code and classifies the affected variables based on their sharing semantics.

97 MATHEMATICS AND COMPUTING↗

Localized Heterogeneous Nucleation for Vapor‐Assisted Sequential Deposition of Metal Halide Perovskites

Vapor-assisted hybrid two-step deposition, which combines thermally evaporated inorganic layers with solution-processed organic halides to form halide perovskites, has emerged as a scalable and industry-compatible route for textured tandem photovoltaics. However, this process is often hindered by reaction-limited phase formation, particularly when compact, non-porous, and highly crystalline inorganic layers formed by thermal evaporation restrict subsequent conversion, resulting in incomplete reaction and pronounced depth-dependent heterogeneity. In this study, we introduce a strategy to regulate the inorganic precursor layer by incorporating localized heterogeneous nucleation sites. Sparsely distributed hydrophilic metal oxide species serve as effective nucleation centers during vapor deposition, enabling effective control over film morphology and crystal orientation from the early stages of growth. This tailored inorganic framework facilitates the subsequent incorporation of organic halides, alleviating reaction limitations and suppressing residual unreacted precursors. Consequently, the perovskite films exhibit improved stoichiometric uniformity and enhanced optoelectronic quality, enabling wide-bandgap perovskite solar cells with markedly improved performance and operational stability. This work provides important mechanistic insight into crystal growth engineering of vapor-deposited perovskite thin films.

nucleation↗

Global land model development: time to shift from a plant functional type to a plant functional trait approach (Final Report)

This project advanced global land models by shifting from the current plant functional type approach to one that better utilizes what is known about the importance and variability of plant traits, within a framework of simultaneously improving fundamental physiological relations that are at the core of model carbon cycling algorithms. A primary goal for Earth system modeling is to make accurate predictions of the future trajectory of the climate system, based on a mechanistic understanding of processes regulating fluxes of mass and energy among system components. Land plays an important role in modifying the Earth’s mass and energy balance, as a critical link in the global cycling of carbon, among others. Land surface models have developed to include mechanistic representations of vegetation physiology, carbon and nutrient dynamics in plants and soils, how they might respond to changing climate and chemistry, and how those changes might feedback to influence changes in atmospheric greenhouse gases themselves. Existing models represent the global distribution of vegetation types using the Plant Functional Type concept. Plant Functional Types are classes of plant species with similar evolutionary and life history with presumably similar responses to environmental conditions like CO 2 , water and nutrient availability. Fixed properties for each Plant Functional Type are specified through a collection of physiological parameters, or traits. These traits, mostly physiological in nature (e.g., leaf nitrogen and longevity) are used in model algorithms to estimate ecosystem properties and/or drive calculated process rates. In most models, 5 to 15 functional types represent terrestrial vegetation; in essence, they assume there are a total of only 5 to 15 different kinds of plants on the entire globe. This assumption of constant plant traits captured within the functional type concept has serious limitations, as a single set of traits does not reflect trait variation observed within and between species and communities. While this simplification was necessary decades past, substantial improvement is now possible. Rather than assigning a small number of constant parameter values to all grid cells in a model, we developed procedures that predict a frequency distribution of values for any given grid cell. Thus, by incorporating the mean and variance model fidelity has been improved. The trait-based approach has improved land modeling by (1) incorporating patterns and heterogeneity of traits into model parameterization, thus evolving away from a framework that considers large areas of vegetation to have near identical trait values and (2) allowing for improved treatment of physiological responses to environmental drivers.

54 ENVIRONMENTAL SCIENCES↗

A phantom design for assessment of detectability in PET imaging

Purpose: The primary clinical role of positron emission tomography (PET) imaging is the detection of anomalous regions of {sup 18}F-FDG uptake, which are often indicative of malignant lesions. The goal of this work was to create a task-configurable fillable phantom for realistic measurements of detectability in PET imaging. Design goals included simplicity, adjustable feature size, realistic size and contrast levels, and inclusion of a lumpy (i.e., heterogeneous) background. Methods: The detection targets were hollow 3D-printed dodecahedral nylon features. The exostructure sphere-like features created voids in a background of small, solid non-porous plastic (acrylic) spheres inside a fillable tank. The features filled at full concentration while the background concentration was reduced due to filling only between the solid spheres. Results: Multiple iterations of feature size and phantom construction were used to determine a configuration at the limit of detectability for a PET/CT system. A full-scale design used a 20 cm uniform cylinder (head-size) filled with a fixed pattern of features at a contrast of approximately 3:1. Known signal-present and signal-absent PET sub-images were extracted from multiple scans of the same phantom and with detectability in a challenging (i.e., useful) range. These images enabled calculation and comparison of the quantitative observer detectability metrics between scanner designs and image reconstruction methods. The phantom design has several advantages including filling simplicity, wall-less contrast features, the control of the detectability range via feature size, and a clinically realistic lumpy background. Conclusions: This phantom provides a practical method for testing and comparison of lesion detectability as a function of imaging system, acquisition parameters, and image reconstruction methods and parameters.

60 APPLIED LIFE SCIENCES↗

Substrate Partitioning into Protein Macromolecular Frameworks for Enhanced Catalytic Turnover

Spatial partitioning of chemical processes is an important attribute of many biological systems, the effect of which is reflected in the high efficiency of enzymes found within otherwise chaotic cellular environments. Barriers, often provided through the formation of compartments or phase segregation, gate the access of macromolecules and small molecules within the cell and provide an added level of metabolic control. Taking inspiration from nature, we have designed virus-like particles (VLPs) as nanoreactor compartments that sequester enzyme catalysts and have used these as building blocks to construct 3D protein macromolecular framework (PMF) materials, which are structurally characterized using small-angle X-ray scattering (SAXS). Additionally, the highly charged PMFs form a separate phase in suspension, and by tuning the ionic strength, we show positively charged molecules preferentially partition into the PMF, while negatively charged molecules are excluded. This molecular partitioning was exploited to tune the catalytic activity of enzymes enclosed within the individual particles in the PMF, the results of which showed that positively charged substrates had turnover rates that were 8500× faster than their negatively charged counterparts. Moreover, the catalytic PMF led to cooperative behavior resulting in charge dependent trends opposite to those observed with individual P22 nanoreactor particles.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-E-I-09: The Impact of X-Ray Scattering On Image Noise for Dedicated Breast CT

Purpose: To quantify the impact of detected x-ray scatter on image noise in flat panel based dedicated breast CT systems and to determine the optimal scanning geometry given practical trade-offs between radiation dose and scatter reduction. Methods: Four different uniform polyethylene cylinders (104, 131, 156, and 184 mm in diameter) were scanned as the phantoms on a dedicated breast CT scanner developed in our laboratory. Both stationary projection imaging and rotational cone-beam CT imaging was performed. For each acquisition type, three different x-ray beam collimations were used (12, 24, and 109 mm measured at isocenter). The aim was to quantify image noise properties (pixel variance, SNR, and image NPS) under different levels of x-ray scatter, in order to optimize the scanning geometry. For both projection images and reconstructed CT images, individual pixel variance and NPS were determined and compared. Noise measurement from the CT images were also performed with different detector binning modes and reconstruction matrix sizes. Noise propagation was also tracked throughout the intermediate steps of cone-beam CT reconstruction, including the inverse-logarithmic process, Fourier-filtering before backprojection. Results: Image noise was lower in the presence of higher scatter levels. For the 184 mm polyethylene phantom, the image noise (measured in pixel variance) was ∼30% lower with full cone-beam acquisition compared to a narrow (12 mm) fan-beam acquisition. This trend is consistent across all phantom sizes and throughout all steps of CT image reconstruction. Conclusion: From purely a noise perspective, the cone-beam geometry (i.e. the full cone-angle acquisition) produces lower image noise compared to the lower-scatter fan-beam acquisition for breast CT. While these results are relevant in homogeneous phantoms, the full impact of scatter on noise in bCT should involve contrast-to-noise-ratio measurements in heterogeneous phantoms if the goal is to optimize the scanning geometry for dedicated breast CT. This work was supported by a grant from the National Institute for Biomedical Imaging and Bioengineering (R01 EB002138)

60 APPLIED LIFE SCIENCES↗

Texas A&M University Mobile Facility Measurements during TRACER (Field Campaign Report)

One of the main goals of the U.S Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Tracking Aerosol Convection Interactions Experiment (TRACER) near Houston, Texas is to improve understanding of how meteorology and aerosols impact storm dynamical and microphysical processes in deep convection to better constrain and improve their model representation. The Houston area is strongly influenced by sea- and bay-breeze circulations that generate convergence and help to initiate and organize deep convection. To properly isolate and understand the roles of varied meteorological conditions and cloud condensation nuclei (CCN) and ice nucleation particles (INP) distributions in different air masses, co-located thermodynamic, kinematic, and aerosol vertical profile observations are needed. The focus of this campaign was to provide key measurements in air masses both in front of and behind sea/bay breeze fronts moving through the greater Houston area to sample the airmass heterogeneity. The overarching scientific goal of this campaign is to understand how the vertical distributions of both CCN and INP correspond to the inflow layer of deep convection in maritime, background continental, and polluted continental air masses, and how these variations influence deep convection. To fully sample the heterogeneity in both meteorological conditions and aerosols across the sea-breeze front (SBF), Texas A&M University (TAMU) deployed a InterMet 3050A 403 MHz mobile unit launching iMet-4 radiosondes and the new Rapid Onsite Atmospheric Measurement Van (ROAM-V) for aerosol sampling during the TRACER intensive operational period (IOP) from June to September 2022. The suite of instruments deployed on ROAM-V included a condensation particle counter (CPC; GRIMM Model 5.403 CPC), scanning mobility particle sizer (SMPS; TSI 3750 detector, TSI 3082 classifier, TSI 3088 neutralizer, TSI 3081A differential mobility analyzer), cloud condensation nuclei counter (Droplet Measurement Technologies CCN counter), micropulse lidar (Droplet Measurement Technologies micropulse lidar [miniMPL]), and a Davis Rotating Uniform size-cut Monitor (DRUM; DRUMAir 4-DRUM). Before sampling at each location, the latitude and longitude were recorded using the Global Positioning System (GPS) on the phone application “My Altitude”. The DRUM data were collected as part of a closely related ARM field campaign and also supported by DOE Atmospheric System Research grant DE-SC0021047. The TAMU team sampled these airmass heterogeneities by strategically choosing deployment sites in a different airmass than the ARM fixed sites in La Porte and Guy, Texas. On days when the sea/bay breeze boundary was pushing inland, the TAMU team would usually sample the airmass on the maritime side of the SBF at a coastal site in Galveston, Texas in the early afternoon (1730-1900 UTC) and then move inland ahead of the SBF to sample the airmass on the continental side during late afternoon (2030-2230). Figure 1 shows the Galveston maritime site and the array of sites for the late afternoon continental measurements.

54 ENVIRONMENTAL SCIENCES↗

Real-Time Analysis and Signal Optimization for Charge Detection Mass Spectrometry

Charge detection mass spectrometry (CDMS) is an important tool for measuring mass distributions for high mass samples and heterogeneous mixtures. In CDMS, single ions are trapped and their m/z and charge are measured simultaneously. As a single particle technique, the average signal must be optimized to maximize the number of single ion trapping events. If the average signal is too small, most of the trapping events will be empty, and if the average signal is too large, most of the trapping events will contain multiple ions. In recent embodiments, the time domain signal from the trapped ion is analyzed by fast Fourier transforms. The analysis time is much longer that the data collection time which precludes real-time optimization of the experimental conditions. In this paper, we describe the implementation of CDMS with real-time analysis. Processing the data in real time allows the average signal intensities to be dynamically optimized to maximize the number of single ion trapping events. Real-time analysis also allows the experimental settings to be optimized in a timely manner to target specific mass regimes to maximize the useful information content of the measurements. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Implementation of EPID transit dosimetry based on a through-air dosimetry algorithm

Purpose: A method to perform transit dosimetry with an electronic portal imaging device (EPID) by extending the commercial implementation of a published through-air portal dose image (PDI) prediction algorithm Van Esch et al.[Radiother. Oncol. 71, 223-234 (2004)] is proposed and validated. A detailed characterization of the attenuation, scattering, and EPID response behind objects in the beam path is used to convert through-air PDIs into transit PDIs. Methods: The EPID detector response beyond a range of water equivalent thicknesses (0-35 cm) and field sizes (3x3 to 22.2x29.6 cm{sup 2}) was analyzed. A constant air gap between the phantom exit surface and the EPID was utilized. A model was constructed that accounts for the beam's attenuation along the central axis, the presence of phantom scattered radiation, the detector's energy dependent response, and the difference in EPID off-axis pixel response relative to the central pixel. The efficacy of the algorithm was verified by comparing predicted and measured PDIs for IMRT fields delivered through phantoms of increasing complexity. Results: The expression that converts a through-air PDI to a transit PDI is dependent on the object's thickness, the irradiated field size, and the EPID pixel position. Monte Carlo derived narrow-beam linear attenuation coefficients are used to model the decrease in primary fluence incident upon the EPID due to the object's presence in the beam. This term is multiplied by a factor that accounts for the broad beam scatter geometry of the linac-phantom-EPID system and the detector's response to the incident beam quality. A 2D Gaussian function that models the nonuniformity of pixel response across the EPID detector plane is developed. For algorithmic verification, 49 IMRT fields were repeatedly delivered to homogeneous slab phantoms in 5 cm increments. Over the entire set of measurements, the average area passing a 3%/3mm gamma criteria slowly decreased from 98% for no material in the beam to 96.7% for 35 cm of material in the beam. The same 49 fields were delivered to a heterogeneous slab phantom and on average, 97.1% of the pixels passed the gamma criteria. Finally, a total of 33 IMRT fields were delivered to the anthropomorphic phantom and on average, 98.1% of the pixels passed. The likelihood of good matches was independent of anatomical site. Conclusions: A prediction of the transit PDI behind a phantom or patient can be created for the purposes of treatment verification via an extension of the Van Esch through-air PDI algorithm. The results of the verification measurements through phantoms indicate that further investigation through patients during their treatments is warranted.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of the Transmission of the Elekta Stereotactic Body Frame (ESBF) and Accounting for it During Treatment Planning

The purpose of this study was to measure the transmission of the Elekta Stereotactic Body Frame (ESBF) and treatment table, to calculate the transmission of the frame in the Eclipse Treatment Planning System (TPS) using analytical anisotropic algorithm (AAA), and to demonstrate a simple method of accounting for this transmission in treatment planning. A solid water body phantom was imaged inside the ESBF and planned with multiple 3D-CRT fields using AAA using both 6-MV and 16-MV energies. In the first set of plans, the frame and table were included in the 'Body' contour and, therefore, used in the dose calculations. In the second set of plans, the frame and the table were not included in the 'Body' contour and, therefore, were not incorporated in the calculations. The latter simulated a setup in which there was no frame or table. Eclipse TPS will only incorporate data from the CT set in calculations, if it is included in the 'Body' contour. The plans were treated under two conditions: one with the phantom in the ESBF and one without the frame on a specially designed table. This table allows all the beams to enter the phantom without passing through any attenuating material (i.e., table or frame). Transmission of the frame and table was determined by the ratio of the measurements with the frame and table to the measurements without them. To validate the accuracy of the calculation model, plans with homogeneous phantom and a heterogeneous plan were compared with the measurements. The transmission of the frame varies from 89-94% depending on the angle of the beams and whether they also intercept the table. The AAA algorithm calculated the transmission of the frame and table to within 2% of the measurements for all gantry angles. Validation results showed that AAA can calculate the dose to the target to within 2% of the measured value. The attenuation caused by the ESBF must be accounted for in the planning process. For Eclipse, the frame should be contoured and included in all calculations. This can be done easily and accurately.

61 RADIATION PROTECTION AND DOSIMETRY↗

Distributed out-of-memory NMF on CPU/GPU architectures

We propose an efficient distributed out-of-memory implementation of the non-negative matrix factorization (NMF) algorithm for heterogeneous high-performance-computing systems. The proposed implementation is based on prior work on NMFk, which can perform automatic model selection and extract latent variables and patterns from data. In this work, we extend NMFk by adding support for dense and sparse matrix operation on multi-node, multi-GPU systems. The resulting algorithm is optimized for out-of-memory problems where the memory required to factorize a given matrix is greater than the available GPU memory. Memory complexity is reduced by batching/tiling strategies, and sparse and dense matrix operations are significantly accelerated with GPU cores (or tensor cores when available). Input/output latency associated with batch copies between host and device is hidden using CUDA streams to overlap data transfers and compute asynchronously, and latency associated with collective communications (both intra-node and inter-node) is reduced using optimized NVIDIA Collective Communication Library (NCCL) based communicators. Benchmark results show significant improvement, from 32X to 76x speedup, with the new implementation using GPUs over the CPU-based NMFk. Good weak scaling was demonstrated on up to 4096 multi-GPU cluster nodes with approximately 25,000 GPUs when decomposing a dense 340 Terabyte-size matrix and an 11 Exabyte-size sparse matrix of density 10 -6 .

97 MATHEMATICS AND COMPUTING↗