Elucidating the role of ferrous ion cocatalyst in enhancing dilute acid pretreatment of lignocellulosic biomass
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
There is an increasing role for biological markers (biomarkers) in the understanding and diagnosis of neurodegenerative disorders. The application of imaging biomarkers specifically for the in vivo investigation of neurodegenerative disorders has increased substantially over the past decades and continues to provide further benefits both to the diagnosis and understanding of these diseases. This review forms part of a series of articles which stem from the University College London/University of Gothenburg course “Biomarkers in neurodegenerative diseases”. In this review, we focus on neuroimaging, specifically positron emission tomography (PET) and magnetic resonance imaging (MRI), giving an overview of the current established practices clinically and in research as well as new techniques being developed. We will also discuss the use of machine learning (ML) techniques within these fields to provide additional insights to early diagnosis and multimodal analysis.
Background: Preoperative chemotherapy provides early treatment of micro-metastases and guaranteed delivery of all components of multimodality therapy for localized pancreatic ductal adenocarcinoma (PDAC). For locally advanced (LA) PDAC, induction chemotherapy is the standard of care. This study evaluated the use of gemcitabine and nab-paclitaxel (Gem/nab-P) as first-line therapy for localized PDAC. Methods: Clinicopathologic features, treatment, and outcomes were evaluated for 99 patients with localized PDAC. The patients were staged using previously published criteria as follows: potentially resectable (PR), borderline type A (BR-A) (anatomy amenable to vascular resection), BR-B (biology suspicious for metastatic disease including high CA19-9), BR–C (comorbidities requiring medical optimization), and LA. Results: The 99 patients (PR/BR/LA: 45/14/40) were treated with Gem/nab-P. Clinical staging showed that 20 patients had PR or BR-A disease, whereas 39 patients had BR-B or BR-C disease. The BR-B+C cases included one or more of the following: age of 80 years or older (13%), Eastern Cooperative Oncology Group performance status (ECOG PS) of 2 or more (13%), moderate to severe comorbidities (55%), CA19-9 of 1000 or higher (28%), and suspicion for metastases (21%). The majority of the patients received biweekly Gem/nab-P dosing, which was well tolerated. Pancreatectomy was performed for 12 (60%) of 20 patients with PR+BR-A, 2 (5%) of 39 patients with BR-B+C, and 1 (3%) of 40 patients with LA disease. During a median follow-up period of 26 months, the median overall survival (OS) period was 18 months (95% confidence interval [CI], 15.6–20.5 months) for all the patients, 17 months (95% CI, 14.6–19.5 months) for the unresected patients, and not reached for the resected patients (p = 0.028 for resected vs unresected patients). Conclusions: A significant number of patients with radiographically resectable PDAC albeit aggressive biology (BR-B), medically inoperable conditions (BR-C), or both received biweekly first-line Gem/nab-P. The resection rates were lower for the BR-B/BR-C patients than for the PR/BR-A patients (hazard ratio [HR], 0.43; 95% CI, 0.19–1.00; p = 0.05).
Current treatment of locally advanced esophageal cancers (ECs) centres on a multimodal approach regardless of histology. While surgery remains the mainstay of curative intent therapy, its implementation alone results in suboptimal outcomes, which have improved significantly with the increased utilization of induction regimens comprising of concurrent chemoradiation (CRT) or chemotherapy alone followed by surgery. Due in large part to the positive results of the CROSS trial, neoadjuvant CRT has become the predominant standard applied in the West. However, the bulk of the data published to date suggests that a more nuanced approach to the management of locally advanced EC is required with respect to the application of radiation, which related to the differential sensitivity of esophageal adenocarcinoma (EAC) and esophageal squamous cell carcinoma (SCC) to radiation. While the latter demonstrates excellent radiosensitivity, which has translated into improved survival outcomes, the same cannot be said for patients with EAC who may be subject to greater toxicity without any benefit. Herein, the differential effectiveness of CRT in patients with EAC versus SCC is highlighted, with a focus on the randomized evidence to date.
This dataset is comprised of in situ sensing data collected during a laser-based powder bed fusion additive manufacturing process, as well as rasterized scan path information, post-build X-ray computed tomography (XCT), and fatigue test results. A total of 64 cylinders, approximately 15 mm in diameter and 102 mm tall, were printed out of stainless steel 316H on a Colibrium Additive Concept Laser M2 Series 5 machine. Parameters known to produce dense material were used to construct 56 of these cylinders, while the remaining 8 cylinders were printed with relatively high energy density parameters prone to producing keyhole pores. In addition, two spatter generation blocks were constructed upstream of the 64 cylinders such that ejecta produced during the melting of the spatter generators were stochastically seeded onto the 64 cylinders. Based on previous experiments, these spatter particles were theorized to produce stochastic lack-of-fusion pores. During the construction of the build, high-resolution images of reflected light in the visible spectrum were captured both before and after recoating for each print layer. Additionally, temporally integrated thermal imaging in the near infrared spectrum produced integrated sum and max images on a layerwise basis. The multimodal in situ data has been co-registered to the build plate coordinate system, allowing for identification of process anomalies (e.g., spatter particles) apparent in the two sensors. Following construction of the build, the cylinders were subjected to XCT to identify internal flaws, and the resulting data have also been registered to the build plate coordinate system. Finally, 60 of the 64 cylinders were machined into fatigue coupons conforming to ASTM E466 and subsequently subjected to either high- or -low-cycle fatigue testing. The results of the fatigue tests have also been included in the dataset, and the XCT data corresponded to the approximate location of the gauge sections of the machine fatigue specimen geometry.
In this study, one of the great challenges of inertial confinement fusion experiments is poor understanding of the effects of reactant heterogeneity on fusion reactions. The Marble campaign, conceived at Los Alamos National Laboratory, aims to gather new insights into this issue by utilizing target capsules containing polymer foams of variable pore sizes, tunable over an order of magnitude. Here, we describe recent and ongoing progress in the development of CH and CH/CD polymer foams in support of Marble. Hierarchical and tunable pore sizes have been achieved by utilizing a sacrificial porogen template within an open-celled poly(divinylbenzene) or poly(divinylbenzene-co-styrene) aerogel matrix, resulting in low-density foams (~30 mg/ml) with continuous multimodal pore networks.
Many advances in our understanding of radiation induced damage mechanisms are due to imaging techniques including transmission electron microscopy and scanning electron microscopy. However, the effect of these radiation induced defects characterized on the atomic to micrometer scale are often interpreted by changes in bulk material properties measured in the hundreds of microns to cm scale. In order to bridge this gap, additional tools need to be developed for use with radioactive materials. To this end a new Asylum Infinity multimodal atomic force microscope (AFM) has been added to the library of Nuclear Science User Facility (NSUF) instruments for use on radioactive materials. This instrument is housed in the Radiochemical Processing Laboratory (RPL) which is a Department of Energy Hazard Category II Non-Reactor Nuclear Facility operated by Battelle at Pacific Northwest National Laboratory. This allows for the handling, sample preparation, and characterization of highly radioactive materials providing a unique capability to understand fundamental properties of nuclear materials and the effects of radiation induced damage.
Reliable and rapid assessment of the transverse mode quality of a free-space laser beam has a wide range of applications in laser development, research, and utilization. It has become even more important with recent advances in developing orbital angular momentum photon beams across a broad spectral region. In this work, a general modal analysis method for a free-space multimode laser beam has been developed based on Bayesian analysis. After transforming mode decomposition into a linear system problem, a Gaussian probabilistic model is used to find a closed-form solution. The method is found to be robust with the presence of Gaussian noise. Prior knowledge about the mode content can be incorporated into the method to improve the solution for situations when coherent disturbances or contamination are present in the laser beam. This method can be used to analyze the mode content for laser beams in different bases, such as Hermite–Gaussian (HG) modes and Laguerre–Gaussian (LG) modes. Three applications of this method are presented: a detailed modal analysis of the beam image from the incoherent intensity addition of HG modes and two examples of mode decomposition using the complex wavefront from the coherent superposition of HG and LG modes. The feasibility of this method is demonstrated using various simulation results. Based on digital images of a laser beam recorded without complex wavelength-limiting optics, in principle, this method can be used in a wide wavelength range from infrared to ultraviolet, and possibly x ray.
A simulation model for an optical fiber bundle distance sensor with a single mode fiber as the illumination fiber and a multimode fiber as the receiving fiber is presented. Approximating the illumination light exiting the single mode fiber as having a Gaussian intensity profile, a closed-form solution of the reflected light coupled into the receiving fiber was derived. A distance sensor was implemented and the measured sensor outputs were compared with the simulation data to verify the theoretical model. The performance of the distance sensor with different design parameters was analyzed. Design guidelines for achieving desired sensor performances are suggested.
Conventional fiber optic evanescent-field gas sensors are based on a high number of total reflections while the gas is passing the active bare core fiber and of course a suitable laser light source. The use of miniaturized laser sources for sensitive detection of CO2 in gaseous and water-dissolved phase for environmental monitoring are studied for signal enhancing purposes. Additionally, the fiber optic sensor, consisting of a coiled bare multimode fiber core, was sensitized by an active polymer coating for the detection of explosive TNT. The implementation of ZnO waveguiding nanowires is discussed for surface and sensitivity enhancing coating of waveguiding elements, considering computational and experimental results.
We describe an ultrahigh-resolution (UHR) retinal imaging system that combines adaptive optics Fourier-domain optical coherence tomography (AO-OCT) with an adaptive optics scanning laser ophthalmoscope (AO-SLO) to allow simultaneous data acquisition by the two modalities. The AO-SLO subsystem was integrated into the previously described AO-UHR OCT instrument with minimal changes to the latter. This was done in order to ensure optimal performance and image quality of the AO- UHR OCT. In this design both imaging modalities share most of the optical components including a common AO-subsystem and vertical scanner. One of the benefits of combining Fd-OCT with SLO includes automatic co-registration between two acquisition channels for direct comparison between retinal structures imaged by both modalities (e.g., photoreceptor mosaics or microvasculature maps). Because of differences in the detection scheme of the two systems, this dual imaging modality instrument can provide insight into retinal morphology and potentially function, that could not be accessed easily by a single system. In this paper we describe details of the components and parameters of the combined instrument, including incorporation of a novel membrane magnetic deformable mirror with increased stroke and actuator count used as a single wavefront corrector. We also discuss laser safety calculations for this multimodal system. Finally, retinal images acquired in vivo with this system are presented.
We describe a multimodal microscope for visualizing processive enzymes moving on immobilized substrates. The instrument combines interference reflection microscopy (IRM) with multi-wavelength total internal reflectance fluorescence microscopy (TIRFM). The microscope can localize quantum dots with a precision of 2.8 nm at 100 frames/s, and was used to image the dynamics of the cellulase, Cel7a interacting with surface-immobilized cellulose. The instrument, which was built with off-the-shelf components and is controlled by custom software, is suitable for tracking other degradative enzymes such as collagenases, as well as motor proteins moving along immobilized tracks.
A multimode fiber methane sensor with polymer-metal organic framework coated cladding is presented. By altering the polymer refractive index through MOF induced methane absorption in various methane concentration, different fiber transmitted power was detected. A low detection limit of 1% (v/v) methane is realized and the detailed mechanism is also analyzed.
We demonstrate the use of spatially multimode two-mode squeezed states (TMSSs) interfered at beamsplitters to generate an arbitrarily large cluster state. A four-mode state is generated using two TMSSs, leveraging spatial modes of four-wave mixing.
We use electro-optic phase modulation to characterize the time-resolved second-order coherence of a multimode signal field generated via pulsed spontaneous four-wave mixing in an integrated 40.5 GHz Si3N4 microring.
A numerical method combining complex-k band calculations and absorbing boundary conditions for Bloch waves is presented. We use this method to study photonic crystals with Dirac cones. We demonstrate that the photonic crystal behaves as a zero-index medium when excited at normal incidence, but that the zero-index behavior is lost at oblique incidence due to excitation of modes on the flat band. We also investigate the formation of monomodal and multimodal cavity resonances inside the photonic crystals, and the physical origins of their different line-shape features.
Light-sheet fluorescence microscopy has greatly improved the speed and overall photostability of optically sectioning cellular and multi-cellular specimens. Similar gains have also been conferred by light-sheet Raman imaging; these schemes, however, rely on diffraction limited Gaussian beams that hinder the uniformity and size of the imaging field-of-view, and, as such, the resulting throughput rates. Here, we demonstrate that a digitally scanned Airy beam increases the Raman imaging throughput rates by more than an order of magnitude than conventional diffraction-limited beams. Overall, this, spectrometer-less, approach enabled 3D imaging of microparticles with high contrast and 1 µm axial resolution at 300 msec integration times per plane and orders of magnitude lower irradiation density than coherent Raman imaging schemes. We detail the apparatus and its performance, as well as its compatibility with fluorescence light-sheet and quantitative-phase imaging towards rapid and low phototoxicity multimodal imaging.