A method to efficiently simulate absorbed dose in radio-sensitive instrumentation components
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
ABSTRACT: Human reliability analysis (HRA), as currently used in risk assessments, largely derives its methods and guidance from application in the nuclear energy domain. While there are many similarities be-tween nuclear energy and other safety critical domains such as oil and gas, there remain clear differences. This paper provides an overview of HRA state of the practice in nuclear energy and then describes areas where refinements to the methods may be necessary to capture the operational context of oil and gas. Many key distinctions important to nuclear energy HRA such as Level 1 vs. Level 2 analysis may prove insignifi-cant for oil and gas applications. On the other hand, existing HRA methods may not be sensitive enough to factors like the extensive use of digital controls in oil and gas. This paper provides an overview of these con-siderations to assist in the adaptation of existing nuclear-centered HRA methods to the petroleum sector.
Pyrolysis temperature and the distance between the source and sensor of effluents are two important variables in tests for relative toxicity. Modifications of the USF/NASA toxicity screening test method to increase the upper temperature limit of pyrolysis, reduce the distance between the sample and the test animals, and increase the chamber volume available for animal occupancy, did not significantly alter rankings of relative toxicity of four representative materials. The changes rendered some differences no longer significant, but did not reverse any rankings. The materials studied were cotton, wool, aromatic polyamide, and polybenzimidazole.
An algorithm for efficiently incorporating the effects of mesh sensitivities in a computational design framework is introduced. The method is based on an adjoint approach and eliminates the need for explicit linearizations of the mesh movement scheme with respect to the geometric parameterization variables, an expense that has hindered practical large-scale design optimization using discrete adjoint methods. The effects of the mesh sensitivities can be accounted for through the solution of an adjoint problem equivalent in cost to a single mesh movement computation, followed by an explicit matrix-vector product scaling with the number of design variables and the resolution of the parameterized surface grid. The accuracy of the implementation is established and dramatic computational savings obtained using the new approach are demonstrated using several test cases. Sample design optimizations are also shown.
An algorithm for efficiently incorporating the effects of mesh sensitivities in a computational design framework is introduced. The method is based on an adjoint approach and eliminates the need for explicit linearizations of the mesh movement scheme with respect to the geometric parameterization variables, an expense that has hindered practical large-scale design optimization using discrete adjoint methods. The effects of the mesh sensitivities can be accounted for through the solution of an adjoint problem equivalent in cost to a single mesh movement computation, followed by an explicit matrix-vector product scaling with the number of design variables and the resolution of the parameterized surface grid. The accuracy of the implementation is established and dramatic computational savings obtained using the new approach are demonstrated using several test cases. Sample design optimizations are also shown.
Abstract not provided.
Conventional x-ray diffraction topography is currently used to map defects in the bulk of protein crystals, but the lack of sufficient contrast is frequently a limiting factor. We experimentally demonstrate that this barrier can be circumvented using a method that combines phase sensitive and diffraction imaging principles. Details of defects revealed in tetragonal lysozyme and cubic ferritin crystals are presented and discussed. The approach enabling the detection of the phase changes of diffracted x rays should prove to be useful in the study of defect structures in a broad range of biological macromolecular crystals.
A method of determining the sensitivity of helicopter maneuver performance to changes in basic rotor design parameters is developed. Maneuver performance is measured by the time required, based on a simplified rotor/helicopter performance model, to perform a series of specified maneuvers. This method identifies parameter values which result in minimum time quickly because of the inherent simplicity of the rotor performance model used. For the specific case studied, this method predicts that the minimum time required is obtained with a low disk loading and a relatively high rotor solidity. The method was developed as part of the winning design effort for the American Helicopter Society student design competition for 1984/1985.
EXO 2030+375 is a 42-second X-ray pulsar orbiting a Be star every 46 days. Previous work using epoch-folded frequency searches over 1-day intervals of BATSE data [1] indicated that EXO 2030+375 underwent a 2.5 year period of quiescence from 1993 September-1996 March. Improvements in the search method that reduced systematic errors due to (1) aperiodic noise from the nearby black hole candidate Cyg X-1 and (2) sources undergoing Earth occultation, have allowed longer time intervals to be searched, hence increasing BATSE's sensitivity. Using the improved method with 4-day intervals, we detect EXO 2030+375 near most of its periastron passages during 1993 September-1996 March and for most periastron passages during BATSE's 9 years in orbit. Earth occultation measurements in the 20-100 keV band, selected when Cyg X-1 was below the Earth's horizon and epoch-folded at EXO 2030+375's orbital period of 46 days, also indicate that EXO 2030+375 was active for most of the mission. We will present histories of EXO 2030+375's pulse frequency and pulsed flux. In addition, we will present results of a pulse timing analysis and evidence that EXO 2030+375's outbursts shift in orbital phase.
Within material test reactor calculations, energy dependent flux and reaction rate uncertainties are typically not quantified when performing as-run analyses to determine the neutron field experienced by the experiment. When high fidelity Monte-Carlo codes are used in such analyses, straight forward methods to calculate output uncertainties are not available, instead expert opinion is used to postulate computational uncertainties. New methods to propagate uncertainties through these high fidelity simulations are available when sufficient computational power is available. A tool is developed here for sampling any part of an MCNP input from random distributions to determine output uncertainties based on those inputs. Another tool is developed to sample nuclear data cross-section in ACE format using multi-group nuclear data covariances. The Total Monte-Carlo Method and Gesellschaft für Anlagen-und Reaktorsicherheit method (GRS) are implemented and compared to one another as well as MCNP sensitivity and uncertainty calculations. The methods were applied to the Godiva critical sphere k-eigenvalue, the UAM pin-cell benchmark energy dependent flux and reaction rates, and the Advanced Test Reactor energy dependent flux within an experimental location. Furthermore, the two methods agree well, with GRS allowing for an order of magnitude speedup for reaction rate uncertainty calculations and several orders of magnitude for eigenvalue uncertainty calculations.
An accurate experimental method is proposed for on-spot calibration of the measurement sensitivities of multiple micro-cantilever dynamic modes in atomic force microscopy. One of the key techniques devised for this method is a reliable contact detection mechanism that detects the tip-surface contact instantly. At the contact instant, the oscillation amplitude of the tip deflection, converted to that of the deflection signal in laser reading through the measurement sensitivity, exactly equals to the distance between the sample surface and the cantilever base position. Therefore, the proposed method utilizes the recorded oscillation amplitude of the deflection signal and the base position of the cantilever at the contact instant for the measurement sensitivity calibration. Experimental apparatus along with various signal processing and control modules was realized to enable automatic and rapid acquisition of multiple sets of data, with which the calibration of a single dynamic mode could be completed in less than 1 s to suppress the effect of thermal drift and measurement noise. Calibration of the measurement sensitivities of the first and second dynamic modes of three micro-cantilevers having distinct geometries was successfully demonstrated. The dependence of the measurement sensitivity on laser spot location was also experimentally investigated. Finally, an experiment was performed to validate the calibrated measurement sensitivity of the second dynamic mode of a micro-cantilever.
This paper presents an experimental demonstration to determine electron temperature (T{sub e}) with unknown spectral sensitivity (transmissivity) in a Thomson scattering system. In this method, a double-pass scattering configuration is used and the scattered lights from each pass (with different scattering angles) are measured separately. T{sub e} can be determined from the ratio of the signal intensities without knowing a real chromatic dependence in the sensitivity. Note that the wavelength range for each spectral channel must be known. This method was applied to the TST-2 Thomson scattering system. As a result, T{sub e} measured from the ratio (T{sub e,r}) and T{sub e} measured from a standard method (T{sub e,s}) showed a good agreement with <|T{sub e,r}-T{sub e,s}|/T{sub e,s}>= 7.3%.
Abstract We developed an adjoint version of a process‐based biogeochemistry model, the Terrestrial Ecosystem Model (TEM). The adjoint model of TEM was then used to: (1) conduct sensitivity studies of net ecosystem production (NEP) for three terrestrial ecosystems: grassland, deciduous broadleaf forest and evergreen needle‐leaf forest; (2) rank the importance of parameters in controlling NEP; (3) optimize the model parameters by assimilating eddy flux data of NEP; and (4) evaluate parameterization by extrapolating optimal parameters to other sites that have the same plant functional type as the calibration sites. We found that: (1) the maximum rate of photosynthesis ( C MAX ) was the most important parameter in determining NEP, while the importance of the remaining parameters varied depending on plant functional type, suggesting that the same ecosystem process has different degrees of importance in modeling carbon fluxes; (2) the sensitivity of NEP to C MAX had a significant seasonal variability and the control of C MAX on NEP was much larger in growing season (defined as from April to October) than that in nongrowing season (defined as from December to March); and (3) after parameterization, TEM could reasonably reproduce carbon fluxes observed at eddy flux tower sites. This study provided an effective model‐data fusion framework of TEM, which could improve the future quantification of terrestrial ecosystem carbon fluxes at both site and regional levels.
Purpose: To evaluate the use of MobiusFX as a pre-treatment verification IMRT QA tool and compare it with a commercial 4D detector array for VMAT plan QA. Methods: 15 VMAT plan QA of different treatment sites were delivered and measured by traditional means with the 4D detector array ArcCheck (Sun Nuclear corporation) and at the same time measurement in linac treatment logs (Varian Dynalogs files) were analyzed from the same delivery with MobiusFX software (Mobius Medical Systems). VMAT plan QAs created in Eclipse treatment planning system (Varian) in a TrueBeam linac machine (Varian) were delivered and analyzed with the gamma analysis routine from SNPA software (Sun Nuclear corporation). Results: Comparable results in terms of the gamma analysis with 99.06% average gamma passing with 3%,3mm passing rate is observed in the comparison among MobiusFX, ArcCheck measurements, and the Treatment Planning System dose calculated. When going to a stricter criterion (1%,1mm) larger discrepancies are observed in different regions of the measurements with an average gamma of 66.24% between MobiusFX and ArcCheck. Conclusion: This work indicates the potential for using MobiusFX as a routine pre-treatment patient specific IMRT method for quality assurance purposes and its advantages as a phantom-less method which reduce the time for IMRT QA measurement. MobiusFX is capable of produce similar results of those by traditional methods used for patient specific pre-treatment verification VMAT QA. Even the gamma results comparing to the TPS are similar the analysis of both methods show that the errors being identified by each method are found in different regions. Traditional methods like ArcCheck are sensitive to setup errors and dose difference errors coming from the linac output. On the other hand linac log files analysis record different errors in the VMAT QA associated with the MLCs and gantry motion that by traditional methods cannot be detected.
The three involute plate research reactors RHF, HFIR, and FRM II have expressed an interest in using computational software to carry their steady-state safety analysis. Since these tools represent a significant departure from the methods used currently (one-dimensional), the acceptability of the new approach by regulators requires thorough verification and validation of these tools. Therefore, Argonne National Laboratory and the three involute-plate reactors formed an informal group called the Involute Working Group aiming at qualifying computational tools to perform steady-state safety analysis. The present report focuses on a comparison of finite volume and finite element methods to model solids in fluid-structure interaction problems with the goal to estimate the coolant flow-induced fuel plate deflections obtained with the two methods. The finite volume method will be obsoleted in STARCCM+ by the end of 2021, nevertheless, this evaluation is important because the method was used by ANL researchers to model the response of the fuel plates, despite its drawbacks, which are discussed in the report. It was essential to check how those estimates compare to the results obtained with the finite element method that is considered superior for structural analysis. Various geometries, i.e., flat, cylindrical and circle-involute fuel plates, as well as coolant flow speed, were considered. The comparison shows that, independently of the plate geometry, the finite volume method significantly underestimates the deflection as compared to finite element method for coarser meshes. When the discretization is developed as a result of a mesh sensitivity study using finite element method, the result obtained using finite volume method can be a few times smaller than the corresponding finite element method solution. A code-to-code comparison , between STAR-CCM+ and LS-DYNA was included in the analysis. Within the LS-DYNA models, two types of finite element formulations were used: solid and shell finite elements. Mesh sensitivity study showed that both approaches converge to a similar value that was obtained with STAR-CCM+ finite element solver. The evaluation of the computational solvers was extended by adding two benchmark cases from the STAR-CCM+ Verification Suite and presented in the Appendix A. The selected cases are: (1) bending of a cantilever beam under external load, and (2) cylindrical shell deformation analysis, known in the literature as ‘Scordelis-Lo roof’. The problems were solved with finite volume, and finite element methods, and the results confirmed the previously discussed findings. The analysis shows that the finite element solver is superior to the finite volume solver in terms of representation of model geometry and estimating the structural behavior of fuel plates. Depending on the ratio of the load to the flexibility of the plate, the finite volume solver can greatly under- or overestimate the structural response if a very carefully selected mesh is not used.
Laboratory and flight radiometric performance testing of an experimental multispectral scanner system is described. High sensitivity performance is confirmed by test results using noise equivalent spectral radiance as the primary figure of merit. A performance comparison between the test-bed aircraft multispectral scanner (TBAMS) and the Bendix modular multispectral scanner (M2S) is presented. Methods for achieving high sensitivity operation are discussed as well as some of the practical implications of such operation for flight remote sensing experiments.
The rutile TiO{sub 2} nanorods (RTNs) with the length of 40-130 nm and diameters approximately 8-15 nm, containing some 300-500 nm sized RTN aggregates and 6% of anatase TiO{sub 2} nanocrystals, were prepared by surfactant-assisted hydrothermal method. The dye-sensitized solar cell (DSC) based on the RTNs exhibited power conversion efficiency of 6.03%. As compared to P25 TiO{sub 2} based DSC, RTNs based DSC shows improved light-harvesting and Brunauer-Emmett-Teller surface area, leading to an increase in short-circuit current (J{sub sc}) by 40.6%.