Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

Implication of spot position error on plan quality and patient safety in pencil-beam-scanning proton therapy

Purpose: To quantitatively and systematically assess dosimetric effects induced by spot positioning error as a function of spot spacing (SS) on intensity-modulated proton therapy (IMPT) plan quality and to facilitate evaluation of safety tolerance limits on spot position. Methods: Spot position errors (PE) ranging from 1 to 2 mm were simulated. Simple plans were created on a water phantom, and IMPT plans were calculated on two pediatric patients with a brain tumor of 28 and 3 cc, respectively, using a commercial planning system. For the phantom, a uniform dose was delivered to targets located at different depths from 10 to 20 cm with various field sizes from 2{sup 2} to 15{sup 2} cm{sup 2}. Two nominal spot sizes, 4.0 and 6.6 mm of 1 σ in water at isocenter, were used for treatment planning. The SS ranged from 0.5 σ to 1.5 σ, which is 2–6 mm for the small spot size and 3.3–9.9 mm for the large spot size. Various perturbation scenarios of a single spot error and systematic and random multiple spot errors were studied. To quantify the dosimetric effects, percent dose error (PDE) depth profiles and the value of percent dose error at the maximum dose difference (PDE [ΔDmax]) were used for evaluation. Results: A pair of hot and cold spots was created per spot shift. PDE[ΔDmax] is found to be a complex function of PE, SS, spot size, depth, and global spot distribution that can be well defined in simple models. For volumetric targets, the PDE [ΔDmax] is not noticeably affected by the change of field size or target volume within the studied ranges. In general, reducing SS decreased the dose error. For the facility studied, given a single spot error with a PE of 1.2 mm and for both spot sizes, a SS of 1σ resulted in a 2% maximum dose error; a SS larger than 1.25 σ substantially increased the dose error and its sensitivity to PE. A similar trend was observed in multiple spot errors (both systematic and random errors). Systematic PE can lead to noticeable hot spots along the field edges, which may be near critical structures. However, random PE showed minimal dose error. Conclusions: Dose error dependence for PE was quantitatively and systematically characterized and an analytic tool was built to simulate systematic and random errors for patient-specific IMPT. This information facilitates the determination of facility specific spot position error thresholds.

60 APPLIED LIFE SCIENCES↗

Generation of attosecond electron bunches upon laser pulse propagation through a sharp plasma boundary

The formation of an electron bunch produced due to electron self-injection into a wake wave that is generated by a relativistic-intensity laser pulse propagating through a sharp boundary of semi-bounded plasma is studied in one-dimensional geometry. Analytical expressions are obtained for estimating the bunch length and the energy spread of electrons in the bunch. Numerical simulation is performed which confirms the results of analytical consideration. (paper)

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Critical current and linewidth reduction in spin-torque nano-oscillators by delayed self-injection

Based on theoretical models, the dynamics of spin-torque nano-oscillators can be substantially modified by re-injecting the emitted signal to the input of the oscillator after some delay. Numerical simulations for vortex magnetic tunnel junctions show that with reasonable parameters this approach can decrease critical currents as much as 25% and linewidths by a factor of 4. Analytical calculations, which agree well with simulations, demonstrate that these results can be generalized to any kind of spin-torque oscillator.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

ON THE HYDRODYNAMIC INTERPLAY BETWEEN A YOUNG NUCLEAR STARBURST AND A CENTRAL SUPERMASSIVE BLACK HOLE

We present one-dimensional numerical simulations, which consider the effects of radiative cooling and gravity on the hydrodynamics of the matter reinserted by stellar winds and supernovae within young nuclear starbursts (NSBs) with a central supermassive black hole (SMBH). The simulations confirm our previous semi-analytic results for low-energetic starbursts, evolving in a quasi-adiabatic regime, and extend them to more powerful starbursts evolving in the catastrophic cooling regime. The simulations show a bimodal hydrodynamic solution in all cases. They present a quasi-stationary accretion flow onto the black hole, defined by the matter reinserted by massive stars within the stagnation volume and a stationary starburst wind, driven by the high thermal pressure acquired in the region between the stagnation and the starburst radii. In the catastrophic cooling regime, the stagnation radius rapidly approaches the surface of the starburst region, as one considers more massive starbursts. This leads to larger accretion rates onto the SMBH and concurrently to powerful winds able to inhibit interstellar matter from approaching the NSB. Our self-consistent model thus establishes a direct physical link between the SMBH accretion rate and the nuclear star formation activity of the host galaxy and provides a good upper limit to the accretion rate onto the central black hole.

79 ASTRONOMY AND ASTROPHYSICS↗

Parsec-scale Obscuring Accretion Disk with Large-scale Magnetic Field in AGNs

A magnetic field dragged from the galactic disk, along with inflowing gas, can provide vertical support to the geometrically and optically thick pc-scale torus in AGNs. Using the Soloviev solution initially developed for Tokamaks, we derive an analytical model for a rotating torus that is supported and confined by a magnetic field. We further perform three-dimensional magneto-hydrodynamic simulations of X-ray irradiated, pc-scale, magnetized tori. We follow the time evolution and compare models that adopt initial conditions derived from our analytic model with simulations in which the initial magnetic flux is entirely contained within the gas torus. Numerical simulations demonstrate that the initial conditions based on the analytic solution produce a longer-lived torus that produces obscuration that is generally consistent with observed constraints.

79 ASTRONOMY AND ASTROPHYSICS↗

Thermostating extended Lagrangian Born-Oppenheimer molecular dynamics

Here, Extended Lagrangian Born-Oppenheimer molecular dynamics is developed and analyzed for applications in canonical (NVT) simulations. Three different approaches are considered: the Nosé and Andersen thermostats and Langevin dynamics. We have tested the temperature distribution under different conditions of self-consistent field (SCF) convergence and time step and compared the results to analytical predictions. We find that the simulations based on the extended Lagrangian Born-Oppenheimer framework provide accurate canonical distributions even under approximate SCF convergence, often requiring only a single diagonalization per time step, whereas regular Born-Oppenheimer formulations exhibit unphysical fluctuations unless a sufficiently high degree of convergence is reached at each time step. Lastly, the thermostated extended Lagrangian framework thus offers an accurate approach to sample processes in the canonical ensemble at a fraction of the computational cost of regular Born-Oppenheimer molecular dynamics simulations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A quantitative risk assessment framework for fault reactivation in underground hydrogen storage: Coupled simulation and deep learning approach

Underground hydrogen storage (UHS) is emerging as a critical solution for large-scale energy storage. However, like all subsurface fluid injection activities, UHS poses the risk of injection-induced fault reactivation. Accurate risk assessment is essential to ensuring the safety and efficiency of UHS operations. This study presents the development of deep-learning surrogate models for fault reactivation prediction in UHS, trained on a comprehensive database of fully coupled fluid flow-geomechanics simulations. Our findings reveal that analytical models often yield unreliable estimates, with errors up to 54% in the allowable injection pressure, potentially leading to a 40% reduction in UHS operational capacity. The developed surrogate models were incorporated into a quantitative risk assessment (QRA) framework, enabling probabilistic evaluation of fault reactivation risk while accounting for uncertainties in the input variables. Site-specific features, such as horizontal stress gradients, fault’s dip and strike angles, and operational parameters like bottom-hole injection pressure and well-fault distance, were identified as the primary drivers of fault reactivation across various stress regimes. Whereas other hydraulic, geological, and poroelastic reservoir properties were found to have a secondary impact. Notably, we observed that the risk of fault reactivation for a critically oriented fault with a static friction coefficient greater than 0.55 remains below 10% in a normal faulting stress regime. However, the risk significantly increases as the stress regime transitions from normal to strike-slip and ultimately to reverse faulting conditions. These findings underscore the importance of rigorous site characterization and comprehensive QRA evaluations to optimize UHS performance and minimize geomechanical risks.

25 ENERGY STORAGE↗

Consideration of a ultracold neutron source in two-dimensional cylindrical geometry by taking simulated boundaries

A new idea to calculate ultracold neutron (UCN) production by using Monte Carlo simulation method to calculate the cold neutron (CN) flux and an analytical approach to calculate the UCN production from the simulated CN flux was given. A super-thermal source (UCN source) was modeled based on an arrangement of D{sub 2}O and solid D{sub 2} (sD{sub 2}). The D{sub 2}O was investigated as the neutron moderator, and sD{sub 2} as the converter. In order to determine the required parameters, a two-dimensional (2D) neutron balance equation written in Matlab was combined with the MCNPX simulation code. The 2D neutron-transport equation in cylindrical (ρ − z) geometry was considered for 330 neutron energy groups in the sD{sub 2}. The 2D balance equation for UCN and CN was solved using simulated CN flux as boundary value. The UCN source dimensions were calculated for the development of the next UCN source. In the optimal condition, the UCN flux and the UCN production rate (averaged over the sD{sub 2} volume) equal to 6.79 × 10{sup 6} cm{sup −2}s{sup −1} and 2.20 ×10{sup 5} cm{sup −3}s{sup −1}, respectively.

36 MATERIALS SCIENCE↗

On the stability of Kuzmin/Toomre disks

A simple two-component system consiting of a Kuzmin/Toomre disk embedded in a spherically symmetrical 'halo' is studied with Plummer's density distribution. The bounds on the mass fraction of the disk component which result from applying the semiempirical criterion against bar instabilities due to Ostriker and Peebles are studied analytically and the results are compared with recent numerical simulations. It is found that the locus t = 0.14, calculated using analytic approximations for a variety of rotation laws, agrees reasonably well with the neutral stability line derived from numerical results.

Frank, Juhan↗

On the use of HDR {sup 60}Co source with the MammoSite Radiation Therapy System

This work summarizes Monte Carlo results in order to evaluate the potential of using HDR {sup 60}Co sources in accelerated partial breast irradiation (APBI) with the MammoSite applicator. Simulations have been performed using the MCNP5 Monte Carlo Code, in simple geometries comprised of two concentric spheres; the internal consisting of selected concentrations, C, of a radiographic contrast solution in water (Omnipaque 300) to simulate the MammoSite balloon and the external consisting of water to simulate surrounding tissue. The magnitude of the perturbation of delivered dose due to the radiographic contrast medium used in the MammoSite applicator is calculated. At the very close vicinity of the balloon surface, a dose build-up region is observed, which leads to a dose overestimation by the treatment planning system (TPS) which depends on Omnipaque 300 solution concentration (and is in order of 2.3%, 3.0%, and 4.5%, respectively, at 1 mm away from the balloon - water interface, for C=10%, 15%, and 20%). However, dose overestimation by the TPS is minimal for points lying at the prescription distance (d=1 cm) or beyond, for all simulated concentrations and radii of MammoSite balloon. An analytical estimation of the integral dose outside the CTV in the simple geometries simulated shows that dose to the breast for MammoSite applications is expected to be comparable using HDR {sup 60}Co and {sup 192}Ir sources, and higher than that for {sup 169}Yb. The higher enegies of {sup 60}Co sources result to approximately twice radiation protection requirements as compared to {sup 169}Ir sources. However, they allow for more accurate dosimetry calculation with currently used treatment planning algorithms for {sup 60}Co sources, compared to {sup 169}Ir.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

NRAP-Open-IAM Multisegmented Wellbore Reduced-Order Model

Geologic carbon storage is one of the promising strategies to mitigate climate change by reducing the emission of carbon dioxide to the atmosphere. As part of the National Risk Assessment Partnership (NRAP), a systems-level stochastic analysis tool called the open source integrated assessment model, NRAP-Open-IAM, has been developed to estimate and manage the risk of containment loss at a geological carbon sequestration site. NRAP-Open-IAM contains several wellbore leakage model components that estimate the fluid leak rate that may occur through compromised legacy wells due to the increase in pressure resulting from CO 2 injection activities. Coupled to a reservoir component model, these components estimate the leakage of CO 2 and/or brine from a storage reservoir to overlying aquifer layers and the atmosphere through legacy wells. This report presents the theoretical framework and quality testing of the multisegmented wellbore reduced-order model. The model allows for segmenting of the legacy wells passing through the overlying stratigraphy into several intervals to simulate a site’s specific stratigraphic and hydrogeologic properties. For quality assurance, the analytical model is validated against numerical reservoir flow simulations for single and multiple aquifer(s) models. The results indicate that the model accurately predicts the transport of two-phase fluids (brine and injected CO 2 ) through the well over time. A detailed description of the model helps users to understand the model and provides a basis for future improvements.

58 GEOSCIENCES↗

THE COSMIC NEAR-INFRARED BACKGROUND. II. FLUCTUATIONS

The near-infrared background (NIRB) is one of a few methods that can be used to observe the redshifted light from early stars at a redshift of 6 and above, and thus it is imperative to understand the significance of any detection or nondetection of the NIRB. Fluctuations of the NIRB can provide information on the first structures, such as halos and their surrounding ionized regions in the intergalactic medium (IGM). We combine, for the first time, N-body simulations, radiative transfer code, and analytic calculations of luminosity of early structures to predict the angular power spectrum (C{sub l} ) of fluctuations in the NIRB. We study in detail the effects of various assumptions about the stellar mass, the initial mass spectrum of stars, the metallicity, the star formation efficiency (f{sub *}), the escape fraction of ionizing photons (f{sub esc}), and the star formation timescale (t{sub SF}), on the amplitude as well as the shape of C{sub l} . The power spectrum of NIRB fluctuations is maximized when f{sub *} is the largest (as C{sub l} {proportional_to} f {sup 2}{sub *}) and f{sub esc} is the smallest (as more nebular emission is produced within halos). A significant uncertainty in the predicted amplitude of C{sub l} exists due to our lack of knowledge of t{sub SF} of these early populations of galaxies, which is equivalent to our lack of knowledge of the mass-to-light ratio of these sources. We do not see a turnover in the NIRB angular power spectrum of the halo contribution, which was claimed to exist in the literature, and explain this as the effect of high levels of nonlinear bias that was ignored in the previous calculations. This is partly due to our choice of the minimum mass of halos contributing to NIRB ({approx}2 x 10{sup 9} M{sub sun}), and a smaller minimum mass, which has a smaller nonlinear bias, may still exhibit a turnover. Therefore, our results suggest that both the amplitude and shape of the NIRB power spectrum provide important information regarding the nature of sources contributing to the cosmic reionization. The angular power spectrum of the IGM, in most cases, is much smaller than the halo angular power spectrum, except when f{sub esc} is close to unity, t{sub SF} is longer, or the minimum redshift at which the star formation is occurring is high. In addition, low levels of the observed mean background intensity tend to rule out high values of f{sub *} {approx}> 0.2.

79 ASTRONOMY AND ASTROPHYSICS↗

Illusion thermodynamics: A camouflage technique changing an object into another one with arbitrary cross section

The previously reported magical thermal devices, such as the thermal invisible cloak and the thermal concentrator, are generalized into one general case named here thermal illusion device. The thermal illusion device is displayed by the design of a thermal reshaper which can reshape an arbitrary thermal object into another one with arbitrary cross section. General expressions of the material parameters for the thermal reshaper are derived unambiguously to greatly facilitate the design of general thermal illusion device. We believe that this work will broaden the current research and pave a path to the thermal invisibility. Numerical simulations show good agreement with the analytical results of the thermal illusion device.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Forward Analytic Model of Neutron Time-of-Flight Signals for Inferring Ion Temperatures from MagLIF Experiments

A forward analytic model is required to rapidly simulate the neutron time-of-flight (nToF) signals that result from magnetized liner inertial fusion (MagLIF) experiments at Sandia’s Z Pulsed Power Facility. Various experimental parameters, such as the burn-weighted fuel-ion temperature and liner areal density, determine the shape of the nToF signal and are important for characterizing any given MagLIF experiment. Extracting these parameters from measured nToF signals requires an appropriate analytic model that includes the primary deuterium-deuterium neutron peak, once-scattered neutrons in the beryllium liner of the MagLIF target, and direct beamline attenuation. Here, mathematical expressions for this model were derived from the general-geometry time- and energy-dependent neutron transport equation with anisotropic scattering. Assumptions consistent with the time-of-flight technique were used to simplify this linear Boltzmann transport equation into a more tractable form. Models of the uncollided and once-collided neutron scalar fluxes were developed for one of the five nToF detector locations at the Z-Machine. Numerical results from these models were produced for a representative MagLIF problem and found to be in good agreement with similar neutron transport simulations. Twenty experimental MagLIF data sets were analyzed using the forward models, which were determined to only be significantly sensitive to the ion temperature. The results of this work were also found to agree with values obtained separately using a zero scatter analytic model and a high-fidelity Monte Carlo simulation. Finally, inherent difficulties in this and similar techniques are identified, and a new approach forward is suggested.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Importance of Three-Body Interactions in Molecular Dynamics Simulations of Water with the Fragment Molecular Orbital Method

The analytic first derivative with respect to nuclear coordinates is formulated and implemented in the framework of the three-body fragment molecular orbital (FMO) method. The gradient has been derived and implemented for restricted Hartree-Fock, second-order Møller-Plesset perturbation, and density functional theories. The importance of the three-body fully analytic gradient is illustrated through the failure of the two-body FMO method during molecular dynamics simulations of a small water cluster. The parallel implementation of the fragment molecular orbital method, its parallel efficiency, and its scalability on the Blue Gene/Q architecture up to 262,144 CPU cores, are also discussed.

Pruitt, Spencer R.↗

A projection-based analytical Jacobian framework for chemical kinetics applications

A major challenge in simulating complex combustion systems with detailed chemical kinetic models is the cost of integrating the chemical source terms, often done using stiff ODE solvers that require frequent Jacobian evaluations. Using analytically derived Jacobian matrices instead of divided-difference-based numerical Jacobian approximations can significantly reduce the associated computational cost. However, ambiguities arise in the formulation of analytical Jacobians because the chemical state of the system, or state vector, can be expressed in multiple ways, involving variables that are typically not independent from one another. Here, in this work, the consequences of those ambiguities on practical calculations are characterized in detail, and a generalized, projection-based framework is proposed as a mitigation strategy. Performances are assessed in a series of test cases involving a variety of configurations and numerical solution approaches. Results show that with proper treatment, commonly used analytical Jacobian formulations can be considered as equivalent for practical purposes, thereby alleviating concerns that the state vector chosen to express the governing equations and corresponding analytical Jacobian may significantly impact the accuracy of the simulations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dust transport in MRI turbulent disks: Ideal and non-ideal MHD with ambipolar diffusion

We study dust transport in turbulent protoplanetary disks using three-dimensional global unstratified MHD simulations including Lagrangian dust particles. The turbulence is driven by the magnetorotational instability (MRI) with either ideal or non-ideal MHD that includes ambipolar diffusion (AD). In ideal MHD simulations, the surface density evolution (except for dust that drifts fastest), turbulent diffusion, and vertical scale height of dust can all be reproduced by simple one-dimensoinal and/or analytical models. However, in AD dominated simulations which simulate protoplanetary disks beyond 10s of AU, the vertical scale height of dust is larger than previously predicted. To understand this anomaly in more detail, we carry out both unstratified and stratified local shearing box simulations with Lagrangian particles, and find that turbulence in AD dominated disks has very different properties (e.g., temporal autocorrelation functions and power spectra) than turbulence in ideal MHD disks, which leads to quite different particle diffusion efficiency. For example, MRI turbulence with AD has a longer correlation time for the vertical velocity, which causes significant vertical particle diffusion and large dust scale height. In ideal MHD the Schmidt numbers (Sc) for radial and vertical turbulent diffusion are Sc{sub r}∼1 and Sc{sub z}≳3, but in the AD dominated regime both Sc{sub r} and Sc{sub z} are ≲1. Particle concentration in pressure bumps induced by MRI turbulence has also been studied. Since non-ideal MHD effects dominate most regions in protoplanetary disks, our study suggests that modeling dust transport in turbulence driven by MRI with non-ideal MHD effects is important for understanding dust transport in realistic protoplanetary disks.

79 ASTRONOMY AND ASTROPHYSICS↗

Slope Efficiency and Voltage Reduction at High Current Densities in AlInGaAs Diode Lasers

Here, the slope efficiency and drive voltage of broad area AlInGaAs laser diodes near 865 nm is observed to decrease significantly under quasi-CW pulsed operation at currents well above threshold, in a manner that cannot be explained by thermal effects or carrier leakage over heterojunction barriers. Simulations show that the slope efficiency reduction is explicable by increased free carrier absorption in the waveguide region. Empirical formulas are presented to represent these effects in a closed analytic form suitable for use in simulators for diode-pumped laser systems.

47 OTHER INSTRUMENTATION↗